Enclosure Cooling Technical Specs

   EMBED


Share

Transcript

Prices as of April 15, 2015. Check Web site for most current prices. Filter Fan Kits Company Information Terminal Blocks Applications 018000-02 Features • Easy filter change • Outer door lock for outdoor models • Impact resistant • Weather/UV resistant UL 94V-0 (indoor)/UL94H-B (outdoor) • No-screw installation - except outdoor models • Low noise • 120 VAC and 24 VDC models available • Service life - 50,000 hrs@77°F (25°C) + 65%RH • Connection type - 12 to 69 CFM - 2 wires w/case clamps, AWG 14, length 4”/136 to 373 CFM - 3 pole terminal, AWG 14, clamping torque 0.8 Nm • Airflow direction easily switched by reversing the axial fan (except on models 018040-01 and 018050-01) • Includes self-adhesive gasket pre-installed on frame • Optional mounting screws for additional support Filter fans provide an optimum climate in enclosures. The interior temperature of enclosures is reduced by channeling cooler filtered outside air into the enclosure, thus expelling heated internal air. The resulting air flow prevents formation of localized heat pockets and protects electronic components from overheating. Outdoor filter fans are used in outdoor enclosures where warm air must be dissipated. To clean and exchange the filter mat, you open the lockable door of the outdoor hood, eliminating the need to allow interior access to the enclosure. IP55 protection type is achieved due to the special design of the hood and the use of fine filter mats. Part Number Standards Free Air Delivery Max. Operating Power Filter Sound Required Amps Rated Consumption Flow Air with Static Temp. Filtering Price Density Level Cutout Level Delivery Exhaust Pressure (Max/Min (g/m2) (mA) Voltage (60 Hz for (dB) Sizes 120V models) (CFM)* (Pa)* °F/°C) (CFM)** Filter Fans 018000-02 $92.00 90 24 VDC 2.2W 12 9 19 018000-01 $68.00 160 120 VAC 13W 14 11 18 018010-02 $101.00 210 24 VDC 5W 32 25 32 018010-01 $75.00 180 120 VAC 15W 37 28 30 018020-02 $104.00 210 24 VDC 5W 60 40 23 39 018020-01 $91.00 180 120 VAC 15W 69 46 27 39 018040-01 $156.00 470 120 VAC 39W 136 84 60 018030-03 $276.00 840 24 VDC 20W 176 135 23 018030-01 $265.00 700 120 VAC 60W 202 156 27 018050-01 $218.00 780 120 VAC 85W 373 203 85 018210-04 $144.00 210 24 VDC 5W 12 11.8 48 018210-02 $123.00 180 120 VAC 15W 14 14 54 31 31 40 158/14 °F (70/-10°C) 40 350 94% 52 3.82 x 3.82 inch (97.03mm x 97.03mm) 4.92 x 4.92 inch (124.97mm x 124.97mm) Multi-wire Connectors Sensor Cables and Connectors M12 Junction Blocks Panel Interface Connectors 53 140/-13°F (60/-25°C) 52 360 98% 40 9.84 x 9.84 inch (249.94mm x 249.94mm) 4.92 x 4.92 inch (124.97mm x 124.97mm) Dimensions in inches (millimeters) *Fan with filter and louver **Fan with filter, louver, exhaust filter, and grille. Book 3 (14.3) Enclosures Thermal Management Cable Ties Wire Bulk Multi-conductor Cables Wire Management Products Power Supplies DC Converters Transformers and Filters Circuit Protection Tools Test Equipment Enclosure Climate Control Safety: Electrical Components Outdoor Filter Fans (Rain Hoods) www.automationdirect.com/enclosures ZIPLink Connection System Enclosures 6.93 x 6.93 inch (176.02mm x 176.02mm) 53 158/14 °F (70/-10°C) 158/14 °F (70/-10°C) Wiring Accessories Wiring Duct All models except outdoor: CE, RoHS, IP55, UL Type 12 when using supplied filter. For use with NEMA 1 and NEMA 12 enclosures only. UL #: E234324 Note: Using fine filter mat F5 reduces the airflow. (See Stego Air Volume and Pressure Data, later in this section.) 140/-13°F (60/-25°C) Power Distribution Blocks EN-259 Safety: Protective Wear Terms and Conditions Prices as of April 15, 2015. Check Web site for most current prices. Filter Fan Kit Cutouts and Dimensions Dimensions [in mm] 018000-01 018000-02 018010-01 018010-02 Book 3 (14.3) EN-260 Enclosures Thermal Management 1-800-633-0405 Prices as of April 15, 2015. Check Web site for most current prices. Filter Fan Kit Cutouts and Dimensions Company Information Terminal Blocks Dimensions [in mm] Power Distribution Blocks 018210-04 018210-02 Wiring Accessories ZIPLink Connection System Multi-wire Connectors Sensor Cables and Connectors M12 Junction Blocks Panel Interface Connectors Wiring Duct Cable Ties Wire Bulk Multi-conductor Cables Wire Management Products Power Supplies DC Converters Transformers and Filters 018020-01 018020-02 Circuit Protection Tools Test Equipment Enclosures Enclosure Climate Control Safety: Electrical Components Safety: Protective Wear Terms and Conditions www.automationdirect.com/enclosures Book 3 (14.3) Enclosures Thermal Management EN-261 Prices as of April 15, 2015. Check Web site for most current prices. Filter Fan Kit Cutouts and Dimensions Dimensions [in mm] 018040-01 018030-01 018030-03 Book 3 (14.3) EN-262 Enclosures Thermal Management 1-800-633-0405 Prices as of April 15, 2015. Check Web site for most current prices. Filter Fan Kit Cutouts and Dimensions Company Information Terminal Blocks Power Distribution Blocks Dimensions [in mm] Wiring Accessories ZIPLink Connection System 018050-01 Multi-wire Connectors Sensor Cables and Connectors M12 Junction Blocks Panel Interface Connectors Wiring Duct Cable Ties Wire Bulk Multi-conductor Cables Wire Management Products Power Supplies DC Converters Transformers and Filters Circuit Protection Tools Test Equipment Enclosures Enclosure Climate Control Safety: Electrical Components Safety: Protective Wear Terms and Conditions www.automationdirect.com/enclosures Book 3 (14.3) Enclosures Thermal Management EN-263 Prices as of April 15, 2015. Check Web site for most current prices. Exhaust Grilles With Filters Features 118000-00 • No-screw installation • Mounting depth 0.6 in. (16mm) Accessories • Come with gaskets attached (adhesive-sided to stick on panel) Part Number Price Filter Density (g/ m2) Mass Filter Level % Exhaust Grilles 118000-00 $15.50 118010-00 $19.50 118020-00 $22.00 118030-00 $56.00 350 94% Outdoor Exhaust Grilles 118210-00 $89.00 360 98% Dimensions in inches (millimeters) Dimensions [in mm] 118000-00 Book 3 (14.3) EN-264 Enclosures Thermal Management 1-800-633-0405 Prices as of April 15, 2015. Check Web site for most current prices. Exhaust Grille and Filter Accessories Company Information Terminal Blocks Power Distribution Blocks 118010-00 Wiring Accessories ZIPLink Connection System Multi-wire Connectors Sensor Cables and Connectors M12 Junction Blocks Panel Interface Connectors Wiring Duct Cable Ties Wire Bulk Multi-conductor Cables Wire Management Products Power Supplies DC Converters 118020-00 Transformers and Filters Circuit Protection Tools Test Equipment Enclosures Enclosure Climate Control Safety: Electrical Components Safety: Protective Wear Terms and Conditions www.automationdirect.com/enclosures Book 3 (14.3) Enclosures Thermal Management EN-265 Prices as of April 15, 2015. Check Web site for most current prices. Exhaust Grille and Filter Accessories 118030-00 118210-00 Book 3 (14.3) EN-266 Enclosures Thermal Management 1-800-633-0405 Prices as of April 15, 2015. Check Web site for most current prices. Replacement Filter Elements 086000-00 Company Information Terminal Blocks Applications Power Distribution Blocks •Replacement filter mats for Stego series filter fans and Stego series exhaust grilles Features Wiring Accessories • Filter media for enclosure fans • Fine or medium density • Fits 3.82 x 3.82, 4.92 x 4.92, 6.93 x 6.93, or 9.84 x 9.84 inch filter fans • Package of 3 ZIPLink Connection System Multi-wire Connectors Sensor Cables and Connectors Replacement Filter Elements Part Number Price 086000-00 $5.00 086010-00 $6.00 086020-00 086080-00 086030-00 With Filter Pieces per Use Fan Kit Package NumberPart 018000-01 018000-02 3 3.5 x 3.5 (88.90x88.90) 118010-00 4.6 x 4.6 (116.84x116.84) G4 (Med.) 018020-01 018020-02 018040-01 018030-01 018030-03 018050-01 018000-01 018000-02 $20.00 118000-00 M12 Junction Blocks Panel Interface Connectors Wiring Duct 018010-01 018010-02 $8.00 $6.00 Mass Dimensions HxW Use With Exhaust Grille Filter Filter Density Filter and Filter Part Number Rating g/m2 Level % in (mm) 350 94 118020-00 6.6 x 6.6 (167.64x167.64) 118030-00 9.7 x 9.7 (246.38x246.38) 118000-00 3.5 x 3.5 (88.90x88.90) Cable Ties Wire Bulk Multi-conductor Cables Wire Management Products Power Supplies 086040-00 086050-00 086090-00 018010-01 018010-02 018210-02 018210-04 118010-00 $12.00 018020-01 018020-02 018040-01 118020-00 $24.00 018030-01 018030-03 018050-01 118030-00 $7.50 4.6 x 4.6 (116.84x116.84) F5 (Fine) 360 DC Converters Transformers and Filters 98 6.6 x 6.6 (167.64x167.64) Circuit Protection Tools 9.7x9.7 (246.38x246.38mm) Test Equipment Enclosures Air Volume and Pressure Data Part Number 018000-02 018000-01 018010-02 018010-01 018020-02 018020-01 018040-01 018030-03 018030-01 018050-01 018210-04 018210-02 Filter Mat Air Volume (cfm) G4 filter free flow* G4 filter with exhaust filter** F5 filter free flow* Filter Mat Static Pressure (Pa) F5 filter with exhaust filter** G4 filter free flow* F5 filter free flow* 12 9 4 3 19 37 14 11 5 4 18 35 32 25 16 13 32 53 37 28 19 15 30 50 60 40 31 21 23 30 69 46 36 24 27 35 136 84 58 36 60 100 176 135 47 36 23 46 202 156 54 42 27 54 373 203 145 83 85 140 30 n/a 12 n/a 48 74 35 n/a 14 n/a 35 54 *Fan with filter and louver **Fan with filter, louver, exhaust filter, and grille. www.automationdirect.com/enclosures Book 3 (14.3) Enclosures Thermal Management EN-267 Enclosure Climate Control Safety: Electrical Components Safety: Protective Wear Terms and Conditions Prices as of October 21, 2015. Check Web site for most current prices. Enclosure Accessories - Miscellaneous Company Information Vapor Capsule Terminal Blocks Power Distribution Blocks Carrying Handle Wiring Accessories ZIPLink Connection System Multi-wire Connectors Sensor Cables and Connectors Carrying Handle Price HW-CARRYINGHANDLE Description Vapor Capsule Wt. Non-metallic black handle, for $16.50 use on Hubbell-Wiegmann 2 oz. non-metallic enclosures. HW-C12 Strip Gasket Price Wt. Non-toxic vapor emitted from the capsule passivates the metal surfaces on the interior of the enclosure against atmospheric corrosion for $13.50 up to one year by reducing the electro-chemical activity of the metal surfaces. Installs easily with a self-adhesive strip. M12 Junction Blocks Panel Interface Connectors 1 oz. Wiring Duct Cable Ties Wire Strip Gasket Price 1 - 14 days Description Wt. WGAS51634 Hubbell-Wiegmann strip gasket, replacement, self-adhesive, microcell urethane foam, $16.00 5/16 inch thick x 3/4 inch wide x 10 ft long roll. For gasket replacement on HubbellWiegmann wall-mount NEMA 12, 4 & 4X enclosures. 7oz. WGAS3834 Hubbell-Wiegmann strip gasket, replacement, self-adhesive, closed cell sponge rubber, $16.00 3/8 inch thick x 3/4 inch wide x 10 ft long roll. For gasket replacement on HubbellWiegmann floor-mount and freestanding NEMA 12, 4 & 4X enclosures. 7oz. Enclosure Shipping Schedule Same day Description Color indicates shipping lead time in business days. Bulk Multi-conductor Cables Wire Management Products Power Supplies DC Converters Transformers and Filters Circuit Protection Dimensions in [mm] Tools Test Equipment Locking Protective Cover Enclosures Enclosure Climate Control Safety: Electrical Components Safety: Protective Wear Terms and Conditions Features • Packaged multi-purpose protective cover • Locking door • Weather and UV resistant (UL 94-HB) • IP 20 Protection Class • Includes mounting screws Locking Protective Cover 086110-00 Description Price Stego multi-purpose protective cover with locking door, weather and UV resistant (UL 94-HB), IP20 protection class. Includes mounting screws and keys. $37.00 Book 3 (14.3) www.automationdirect.com/enclosures Enclosures Accessories EN-239 Prices as of April 15, 2015. Check Web site for most current prices. Enclosure Cooling – Selecting a Fan or Air Conditioner Fan selection Fan Selection Example To select the proper size (CFM) fan for your forced air cooling solution, you need to determine the amount of heat to be removed (in watts) and determine the Delta T (Max. allowable internal enclosure temperature °F – Max. outside ambient temperature°F). CFM = Cubic Feet per Minute P = Power to be dissipated in watts CFM = (3.17 x Pwatts) / Delta T °F Delta T = m  ax. allowable internal enclosure temperature °F – max. outside ambient temperature °F A NEMA 12 Hubbell Wiegmann N12302412 enclosure (30” high x 24” wide x 12” deep) contains a GS3-2020 AC drive (20 HP 230 volt) that has a maximum allowable operating temperature of 104°F and is located in a warehouse that has a maximum outside ambient air temperature of 95°F. Power to be dissipated is stated in the specifications of the GS3-2020 and is found to be 750 watts, so P=750 watts Delta T = Max. operating temperature for the GS3-2020 is 104°F – Max. ambient air temperature of 95°F Delta T = 9°F CFM = (3.17 x 750 watts) / 9°F CFM = 264 Choose a Hubbell Wiegmann WPF60-115BK filter fan kit that provides 295 CFM with exhaust kit WPFA50-60BK Air conditioner and vortex cooler selection To select the proper size air conditioner or vortex cooler, the worst-case conditions should be considered, but take care not to choose an oversized unit. There are two main factors in choosing an uninsulated metal NEMA rated enclosure located indoors: • Internal heat load • Heat load transfer Internal Heat Load Internal heat load is the heat generated by the components inside the enclosure. This can be determined by a few different methods. The preferred method is to add the maximum heat output specifications that the manufacturers list for all the equipment installed in the cabinet. This is typically given in Watts, so use the following conversion: BTU per Hour = Watts x 3.413 Example: The Watt-loss chart for the GS3 Drives shows that a GS3-2020 AC drive has a Watt-loss of 750 watts. BTU per Hour = 750 watts x 3.413 BTU per Hour = 2559 Heat Load Transfer Heat load transfer is the heat lost (negative heat load transfer) or gained (positive heat load transfer) through the enclosure walls with the surrounding ambient air. This can be calculated by the following formula: Heat load transfer (BTU/H) = 1.25 x surface area (sq. ft. ) x (max. outside ambient air (°F) – max. allowable internal enclosure temperature air (°F)) Surface Area (sq. ft.) = 2 [(H x W) + (H x D) + (W x D)] / 144 sq. inches Air Conditioner Selection Example A NEMA 12 Hubbell Wiegmann N12302412 enclosure (30” high x 24” wide x 12” deep) contains a GS3-4030 AC drive 30 HP 460 volt) that has a maximum allowable operating temperature of 104°F and is located in a warehouse that has a maximum outside ambient air temperature of 115°F. Power to be dissipated is stated in the specifications of the GS3-4030 and is found to be 1290 watts. Internal heat load: BTU per Hour = 1290 watts x 3.413 BTU per Hour = 4403 BTU/H Heat load transfer: Heat load transfer (BTU/H) = 1.25 x 19 sq. ft. x (115°F – 104°F) Heat load transfer (BTU/H) = 261.25 BTU/H Cooling capacity: Cooling capacity (BTU/H) = 4403 BTU/H + 261.25 BTU/H Cooling capacity (BTU/H) = 4664.25 BTU/H In this example, you are able to determine that a 5000 BTU/H unit is needed. Select a TA10-050-16-12 Stratus air conditioner. Note: The same calculation method is used for sizing Stratus vortex coolers. However, in this example the cooling requirements exceed the maximum capacity of the largest available vortex cooler. If the example application required the use of a vortex cooler instead of an air conditioner, two (2) TV35-025-4X units would be needed. Thermal Expansion Valve Evaporator Condenser Note: 1.25 is an industry standard constant for metal enclosures; 0.62 should be used for plastic enclosures. Once you have determined your Internal Heat Load and the Heat Load Transfer, you can choose the proper size unit by calculating the needed cooling capacity. Compressor Cooling capacity (BTU/H) = Internal Heat Load ± Heat Load Transfer Book 3 (14.3) EN-242 Enclosures Thermal Management 1-800-633-0405 Prices as of April 15, 2015. Check Web site for most current prices. Enclosure Cooling – Selecting a Heat Exchanger Heat exchanger selection To select the proper size heat exchanger, the worst-case conditions should be considered. For a heat exchanger to work, the ambient air temperature must be lower than the desired internal enclosure air temperature. There are three main factors in choosing a heat exchanger for an uninsulated metal NEMA rated enclosure located indoors: • Internal heat load • Delta T • Heat load transfer Internal Heat Load Internal heat load is the heat generated by the components inside the enclosure. This can be determined by a few different methods. The preferred method is to add the maximum heat output specifications that the manufacturers list for all the equipment installed in the cabinet. This is typically given in Watts. Delta T (ΔT) Delta T = maximum allowable internal enclosure temperature °F – maximum outside ambient temperature °F. Heat Load Transfer Heat load transfer is the heat lost (negative heat load transfer) or gained (positive heat load transfer) through the enclosure walls with the surrounding ambient air. This can be calculated by the following formulas: Surface Area (sq. ft.) = 2 [(H x W) + (H x D) + (W x D)] / (144 sq. inches/sq. ft.) Company Information Terminal Blocks Power Distribution Blocks Wiring Accessories Heat Exchanger Selection Example A NEMA 12 Hubbell Wiegmann N12302412 enclosure (30” high x 24” wide x 12” deep) contains a GS3-4010 AC drive 10 HP 460 volt) that has a maximum allowable operating temperature of 104°F and is located in a warehouse that has a maximum outside ambient air temperature of 90°F. ZIPLink Connection System Power to be dissipated is stated in the specifications of the GS3-4010 and is found to be 345 watts. Sensor Cables and Connectors Multi-wire Connectors M12 Junction Blocks Internal heat load: Panel Interface Connectors Internal Heat Load = 345 Watts Wiring Duct Delta T: Cable Ties ΔT (°F) 104°F – 90°F = 14°F Wire Heat load transfer: Surface Area (ft.2) = 2 [(30 x 24) + (30 x 12) + (24 x 12)] / 144 sq. inches = 19 ft.2 Heat Load Transfer = 0.22 x 19 ft2 = 4.2 Watts/°F Cooling capacity: Cooling Capacity = 345 Watts/14°F - 4.2 Watts/°F = 20.4 Watts/°F Bulk Multi-conductor Cables Wire Management Products Power Supplies DC Converters In this example, you are able to determine that a Stratus heat exchanger, with a capacity of at least 20.4 Watts/°F is needed, such as a TE30-030-17-04. Transformers and Filters Circuit Protection *This selection procedure applies to metal and non-metal, uninsulated, sealed enclosures in indoor locations. This selection procedure gives the minimum required size; be careful not to undersize when purchasing. Note: Only include exposed surfaces of enclosue in calculations. Exclude surfaces such as a surface mounted to a wall. Test Equipment Enclosures Enclosure Climate Control Safety: Electrical Components Heat Load Transfer (W/°F) = 0.22 W/°F sq. ft. x surface area Safety: Protective Wear Note: Use 0.22 Watts/°F sq. ft. for painted steel and nonmetallic enclosures. Use .10 Watts/°F sq. ft. for stainless steel and bare aluminum enclosures. Terms and Conditions Cooling Capacity Once you have determined your Internal Heat Load, the Heat Load Transfer and the Delta T, you can choose the proper size unit by calculating the needed cooling capacity. Cooling Capacity (W/°F) = Internal Heat Load / ∆T - Heat Load Transfer www.automationdirect.com/enclosures Tools Book 3 (14.3) Enclosures Thermal Management EN-243 Prices as of April 15, 2015. Check Web site for most current prices. This “.com” is powered by “.awesomepeople” Check us out for our prices, keep coming back for our service. For over twenty years our sole focus has been customer service. That takes many forms: great prices, fast delivery, and quality products. But regardless of our product selection and other tangibles like pricing, the intangible value of customer service is something that cannot be faked, replaced by machinery or glossed over with a free lunch from a visiting sales rep. Our team members here at AutomationDirect.com approach every day with this one goal in mind - serve the customer. It’s a simple philosophy that many companies forget or make too complex and then fail at it. If the answer to any decision is “Yes, this is good for our customers”, then we do it. It’s that simple. “Should we have real upfront pricing online and realtime stock availability? Yes, this is good for our customers.” “Should we have FREE tech support before, during, and after any sale instead of charging yearly fees for tech support? Yes, this is good for our customers.” “Should we offer FREE software on many products instead of charging licensing fees? Yes, this is good for our customers.” “Should we have all our documentation online for FREE so people can access anytime, even before they choose to purchase? Yes, this is good for our customers.” “Should we offer more selection by consistenly introducing more new quality products with great prices monthly, sometimes weekly? Yes, this is good for our customers.” “Should we offer FREE shipping for orders over $49? Yes, this is good for our customers.” Voted #1 in service since 2001: “Should we be fiscally responsible and run an efficient business so customers can rely on us decade after decade after decade? Yes, this is good for our customers.” www.automationdirect.com/awards Voted #1 mid-size company to work for in Atlanta: www.automationdirect.com/workplace Our company has evolved dramatically since 1994 and it’s this type of decision making by all our team members over the years that keeps our customers coming back and new customers checking us out daily. What our current customers think: If you’re a current customer, we sincerely thank you for your business. We wouldn’t be here if it wasn’t for you and promise to do our best for you every day. If you’re new and checking us out for the first time, we hope you give us an opportunity to serve you. www.automationdirect.com/reviews Book 3 (14.3) All these are discussions we’ve had internally and all have had certain aspects of “can we do that?”, “that will be hard to accomplish”, “no one else is doing that, how can we?”. But if you bring it back to the simple answer, “Yes, this is good for our customers”, then the perceived obstacles really don’t matter. EN-244 Enclosures Thermal Management 1-800-633-0405 Prices as of April 15, 2015. Check Web site for most current prices. Air Conditioners For NEMA 12 Enclosures Applications Company Information Terminal Blocks Power Distribution Blocks Features Construction • F ree-standing rigid chassis for easy installation and maintenance • F abricated from 16-gauge cold rolled steel •A  NSI-61 gray polyester powder coating inside and out • P re-cut mounting gasket included, to be field installed •A  ll mounting hardware, full-size template and instruction manual included • Power input terminal block on all models Wiring Accessories • Digital LED temperature controller with visible alarm features and 14.2 mm (0.55”) numbers • Pre-wired for external alarm monitoring connections (22 AWG three-conductor cable, 7 ft. long) • CFC-free refrigerant • Active condensate management system • Thermal expansion valve for maximum efficiency over wide range of temperatures and loads • Fits 12 inch deep enclosures that have smooth/flat sides. Check enclosure dimensions/specifications before ordering. • Anti short-cycle compressor protection • High and low refrigerant cut-outs with fault indication • Highly energy-efficient compressors • UL/cUL listed Designed to maintain the temperature inside an electrical enclosure at or below a safe level for the enclosed equipment, while maintaining a closed loop environment inside the enclosure to keep out contaminates that can be in the ambient air. Can be used in such environments as steel, food processing, petro-chemical, cement, paper/pulp and plastics industries. ZIPLink Connection System Multi-wire Connectors Sensor Cables and Connectors M12 Junction Blocks Panel Interface Connectors Wiring Duct Cable Ties Wire Bulk Multi-conductor Cables Listings • UL File: SA33404 • UL 50, Type 12 • Made in USA Wire Management Products Power Supplies DC Converters TA10-060-26-12 shown Part Number Price BTU/Hour Voltage/Hz Running Amps TA10-010-16-12 $1,266.00 TA10-010-26-12 $1,481.00 TA10-015-16-12 $1,536.00 TA10-015-26-12 $1,607.00 TA10-020-16-12 $1,633.00 TA10-020-26-12 $1,713.00 TA10-020-46-12 $2,323.00 TA10-040-16-12 $1,757.00 TA10-040-26-12 $1,841.00 TA10-040-46-12 $2,378.00 TA10-050-16-12 $1,909.00 TA10-050-26-12 $1,941.00 TA10-050-46-12 TA10-060-16-12 TA10-060-26-12 $2,226.00 TA10-060-46-12 $3,213.00 Weight with/without Packaging (lbs) 120/60 3.44 72/54 230/60 2.67 72/54 120/60 3.89 72/54 230/60 2.67 72/54 120/60 5.15 87/69 230/60 3.07 87/69 480/60 1.51 113/95 120/60 3.76 88/70 230/60 3.07 88/70 480/60 0.93 114/96 120/60 7.26 107/89 230/60 3.76 107/89 $2,928.00 480/60 1.44 150/132 $2,205.00 120/60 7.83 114/96 230/60 4.80 114/96 480/60 1.80 157/39 1000 1500 2000 3000 - 4000 5000 6000 - 8000 Max. Ambient Frame Temp Size 1 Circuit Protection Tools Test Equipment Enclosures Enclosure Climate Control Safety: Electrical Components 2 125°F (51.67°C) 3 Book 3 (14.3) Enclosures Thermal Management Safety: Protective Wear Terms and Conditions * Voltage variation no greater than ± 10% from nameplate rating and Frequency variation no greater than ± 3Hz from nameplate rating. www.automationdirect.com/enclosures Transformers and Filters EN-245 Prices as of April 15, 2015. Check Web site for most current prices. Air Conditioners For NEMA 4 Enclosures Applications Features • Digital LED temperature controller with visible alarm features and 14.2 mm (0.55”) numbers • Pre-wired for external alarm monitoring connections (22 AWG three-conductor cable, 7 ft. long) • CFC-free refrigerant • Protective coated condenser coils for corrosion resistance • Active condensate management system • Thermal expansion valve for maximum efficiency over wide range of temperatures and loads • Fits 12-inch deep enclosures that have smooth/flat sides. Check enclosure dimensions/specifications before ordering. • Anti short-cycle compressor protection • High and low refrigerant cut-outs with fault indication • Highly energy-efficient compressors • UL/cUL listed Designed to maintain the temperature inside an electrical enclosure at or below a safe level for the enclosed equipment, while maintaining a closed loop environment inside the enclosure to keep out contaminates that can be in the ambient air. Can be used in such environments as steel, food processing, petro-chemical, cement, paper/pulp and plastics industries. Construction • Free-standing rigid chassis for easy installation and maintenance • Fabricated from 16-gauge cold rolled steel • ANSI-61 gray polyester powder coating inside and out • Pre-cut mounting gasket installed for NEMA/ UL type rating on all units • All mounting hardware, full-size template and instruction manual included • Power input terminal block on all models Listings • UL File: SA33404 • UL 50, Type 4 • Made in USA TA10-060-26-04 shown Part Number Price TA10-010-16-04 TA10-010-26-04 TA10-015-16-04 TA10-015-26-04 TA10-020-16-04 TA10-020-26-04 TA10-020-46-04 TA10-040-16-04 TA10-040-26-04 TA10-040-46-04 TA10-050-16-04 TA10-050-26-04 TA10-050-46-04 TA10-060-16-04 TA10-060-26-04 $1,575.00 TA10-060-46-04 $3,378.00 $1,599.00 $1,657.00 $1,737.00 BTU/Hour 1000 1500 $1,763.00 $1,778.00 Running Amps Weight with/without Packaging (lbs) 120/60 3.44 72/54 230/60 2.67 72/54 120/60 3.89 72/54 230/60 2.67 72/54 120/60 5.15 87/69 230/60 3.07 87/69 $2,343.00 480/60 1.51 113/95 $1,896.00 120/60 3.76 88/70 $1,907.00 2000 Voltage/Hz 3000 - 4000 230/60 3.07 88/70 $2,400.00 480/60 0.93 114/96 $2,059.00 120/60 7.26 107/89 $2,089.00 5000 230/60 3.76 107/89 $3,073.00 480/60 1.44 150/32 $2,366.00 120/60 7.83 114/96 230/60 4.80 114/96 480/60 1.80 157/139 $2,394.00 6000 - 8000 Max. Ambient Temp Frame Size 1 2 125°F (51.67°C) 3 * Voltage variation no greater than ± 10% from nameplate rating and Frequency variation no greater than ± 3Hz from nameplate rating. Book 3 (14.3) EN-246 Enclosures Thermal Management 1-800-633-0405 Prices as of April 15, 2015. Check Web site for most current prices. Air Conditioners For NEMA 4X Enclosures Applications Company Information Terminal Blocks Power Distribution Blocks Features • Digital LED temperature controller with visible alarm features and 14.2 mm (0.55”) numbers • Pre-wired for external alarm monitoring connections (22 AWG three-conductor cable, 7 ft. long) • CFC-free refrigerant • Protective coated condenser coils for corrosion resistance • Active condensate management system • Thermal expansion valve for maximum efficiency over wide range of temperatures and loads • Fits 12-inch deep enclosures that have smooth/flat sides. Check enclosure dimensions/specifications before ordering. • Anti short-cycle compressor protection • High and low refrigerant cut-outs with fault indication • Highly energy-efficient compressors • UL/cUL listed Designed to maintain the temperature inside an electrical enclosure at or below a safe level for the enclosed equipment, while maintaining a closed loop environment inside the enclosure to keep out contaminates that can be in the ambient air. Can be used in such environments as steel, food processing, petro-chemical, cement, paper/pulp and plastics industries. Construction • F ree-standing rigid chassis for easy installation and maintenance • F abricated from 16-gauge 304 stainless steel • P re-cut mounting gasket installed for NEMA/ UL type rating on all units •A  ll mounting hardware, full-size template and instruction manual included • P ower input terminal block on all models Wiring Accessories ZIPLink Connection System Multi-wire Connectors Sensor Cables and Connectors M12 Junction Blocks Panel Interface Connectors Wiring Duct Cable Ties Wire Bulk Multi-conductor Cables Listings Wire Management Products • UL File: SA33404 • UL 50, Type 4X • Made in USA TA10-060-16-4X shown Power Supplies DC Converters Transformers and Filters Part Number Price BTU/Hour Voltage/Hz Running Amps Weight with/without Packaging (lbs) 120/60 3.44 72/54 230/60 2.67 72/54 120/60 3.89 72/54 230/60 2.67 72/54 120/60 5.15 87/69 TA10-010-16-4X $2,341.00 TA10-010-26-4X $2,367.00 TA10-015-16-4X $2,426.00 TA10-015-26-4X $2,452.00 TA10-020-16-4X $2,434.00 TA10-020-26-4X $2,495.00 230/60 3.07 87/69 TA10-020-46-4X $2,740.00 480/60 1.51 113/95 TA10-040-16-4X $2,857.00 120/60 3.76 88/70 TA10-040-26-4X $2,923.00 230/60 3.07 88/70 TA10-040-46-4X $2,923.00 480/60 0.93 114/96 TA10-050-16-4X $2,904.00 120/60 7.26 107/89 TA10-050-26-4X $2,931.00 230/60 3.76 107/89 TA10-050-46-4X $3,248.00 480/60 1.44 150/132 TA10-060-16-4X $3,106.00 120/60 7.83 114/96 TA10-060-26-4X $3,131.00 230/60 4.80 114/96 TA10-060-46-4X $3,448.00 480/60 1.80 157/139 1000 1500 2000 3000 - 4000 5000 6000 - 8000 www.automationdirect.com/enclosures Max. Ambient Temp Frame Size Circuit Protection Tools Test Equipment 1 Enclosures Enclosure Climate Control Safety: Electrical Components 2 125°F (51.67°C) Terms and Conditions 3 Book 3 (14.3) Enclosures Thermal Management Safety: Protective Wear EN-247