Preview only show first 10 pages with watermark. For full document please download

Energizer Cr2016

   EMBED


Share

Transcript

PRODUCT DATASHEET 1-800-383-7323 USA/CAN www.energizer.com ENERGIZER CR2016 Lithium Coin Specifications Classification: Chemical System: Designation: Nominal Voltage: Typical Capacity: Industry Standard Dimensions mm (inches) This Battery has Underwriters Laboratories component Recognition Typical Weight: Typical Volume: Max Rev Charge: Energy Density: Typical Li Content: UL Recognized: Operating Temp: Self Discharge: "Lithium Coin" Lithium / Manganese Dioxide (Li/MnO2) ANSI / NEDA-5000LC, IEC-CR2016 3.0 Volts 90 mAh (to 2.0 volts) (Rated at 30K ohms at 21°C) 1.9 grams (0.07 oz.) 0.5 cubic centimeters (0.03 cubic inch) 1 microampere 122 milliwatt hr/g, 464 milliwatt hr/cc 0.036 grams (0.0013 oz.) MH29980 -30C to 60C ~1% / year 1.60 (0.063) 20.00 (0.787) 1.47 (0.058) Ref. 19.80 (0.780) 8.00 (0.314) 1.22 (0.048) Ref. Minimum 0.08 (0.003) Minimum Ref. (Applies to top edge of gasket or edge of crimp, whichever is higher.) 0.20 (0.008) Maximum Ref. Permissible deflection from a flat. Simulated Application test Typical Performance at 21°C (70°F) Schedule: Typical Drains: at 2.9V (mA) (ohms) Cutoff 2.0V (hours) 0.097 30,000 928 Continuous Load Safety: (1) KEEP OUT OF REACH OF CHILDREN. Swallowing may lead to serious injury or death in as little as 2 hours due to chemical burns and potential perforation of the esophagus. Immediately see doctor; have doctor phone (202) 625-3333. (2) Battery compartment design. To prevent children from removing batteries, battery compartments should be designed with one of the following methods: a) a tool such as screwdriver or coin is required to open battery compartment or b) the battery compartment door/cover requires the application of a minimum of two independent and simultaneous movements of the securing mechanism to open by hand. Screws should remain captive with the battery door or cover. Internal Resistance Characteristics Pulse Test at 21°C (70°F) Bkgnd Drain: Continuous 30K ohms 0.097 mA @2.9V Typical Discharge Characteristics Pulse Drain: 2 seconds X 12 times/day 400 ohms 6.8 mA @2.7V 3.2 3.0 2.8 2.6 2.4 2.2 2.0 1.8 Voltage, CCV Voltage, CCV Load: 30K ohms - Continuous Typical Drain @ 2.9V: 0.097 mA 0 200 400 600 Service, Hours 800 1000 3.2 3.0 2.8 2.6 2.4 2.2 2.0 1.8 120 Bkgnd 100 80 Pulse 60 40 20 IR 0 Important Notice 10 20 30 40 50 60 70 80 0 90 100 Capacity, mAh This datasheet contains typical information specific to products manufactured at the time of its publication. ©Energizer Holdings, Inc. - Contents herein do not constitute a warranty. Form No. EBC - 4118H Page 1 of 1 IR, ohms 1.40 (0.055)