Transcript
EVEREADY BATTERY CO. Internet: www.energizer.com
1-800-383-7323 / USA 1-800-383-7323 / CANADA
ENERGIZER NO. 521
6V Chemical System:
Designation: Battery Voltage: Operating Temp: Average Capacity:
Industry Standard Dimensions in mm (inches)
Average Weight: Volume: Cell: Jacket: Terminal:
Alkaline Zinc-Manganese Dioxide (Zn/MnO2) (No Added Mercury or Cadmium) ANSI-918A, IEC-4LR25-2 6.0 Volts -18ºC to 55ºC (0ºF to 130ºF) 52,000 mAh (to 0.8 volts / cell) (Rated capacity at 25 mA continuous drain.) 1,900 grams (67.3 oz.) 1,123 cubic centimeters (68.5 cubic inch) Eight No. 3-361 Two parallel strings of four in series Metal Screw Post
PORTABLE LIGHTING Continuous Tests @ 20ºC 7.0
Voltage, CCV
6.0 5.0 4.0 5.0 ohm
9.1 ohm
3.0 2.0 0
20
10000
10000
1000
1000
Service Hours
Service, Hours
80
100
CONSTANT CURRENT DISCHARGE Typical Service
CONSTANT RESISTANCE PERFORMANCE Typical Service
100
3.0 Cutoff Voltage
10
40 60 Service, Hours
100
3.0 Cutoff Voltage 4.4 Cutoff Voltage
10 5.2 Cutoff Voltage
4.4 Cutoff Voltage 1
1
5.2 Cutoff Voltage
0.1
0.1 1
10 100 Discharge Resistance, Ohms
1000
1
10
100
1000
Discharge Current, mA
Important Notice This data sheet contains information specific to batteries manufactured at the time of its publication. Contents herein do not constitute a warranty. Copyright © Eveready Battery Co. - All rights reserved Form No. EBC - 1107D