Preview only show first 10 pages with watermark. For full document please download

Enerwa / Enerwaplus

   EMBED


Share

Transcript

24/31 - 28/35 - 32/40 kW Premix System Condensing - ErP Combi Gas Boilers Enerwa / EnerwaPlus Condensing-ErP Premix System Boilers 24/31 - 28/35 - 32/40 kW Warmhaus wall-hung gas combi boilers Enerwa and EnerwaPlus, with the advantage of its width as 288 mm, are easily fit to narrow places to assemble. EnerwaPlus Control Panel Features » 3” LCD - Black and Orange display and black digits-symbols colors control panel with 6 push-buttons: MODE, RESET, CH and DHW easy digital buttons for the hot water and heating water temperatures » Visuals of hot water temperature and All-in-one smart digital display with push button heating temperature on LCD screen » Flame modulation indicator » ±1 °C temperature sensitivity » Digital manometer showing the pressure General Features » Compatible with ErP directive (2009/125 / CE) » Auto- diagnosis codes & identification system » Different working parameters condensing combi gas boilers » 108.4% efficiency with stainles steel heat exchanger » EU environnemental compliance combi » Three power options: 24/31, 28/35 and 32/40 kW » High DHW capacity » 3” LCD display (Enerwa Plus) » ± 1 degree heat sensitivity » 10 mm whole body insulation » Stainless steel DHW heat exchanger » Gas adaptive system » High savings with 1:10 modulation on 24/31 kW » Electronic control power pump (7,5 h/m) more stronger & quieter circulation » Both LPG and natural gas compatible » Low pressure safety » Automatic trouble shooting system » Low emission » Double NTC sensor system » Weekly adjustable digital room thermostats (optional) » Outdoor temperature sensor (optional) EnerwaPlus 24/31 EnerwaPlus 28/35 EnerwaPlus 32/40 2 Condensing-ErP Premix System Boilers 24/31 - 28/35 - 32/40 kW Enerwa Control Panel Features » 2” LCD control panel - Dark blue display and white digits-symbols colors » MODE and RESET buttons » Easy analog buttons for the hot water and heating » Flame modulation indicator Easy-to-use LCD display with knobs and push buttons » ±1 °C temperature sensitivity » Auto - diagnosis codes & identification system » Different working parameters condensing combi gas boilers General Features » Compatible with ErP directive (2009/125 / CE) » 108.4% efficiency with stainles steel heat exchanger » EU environnemental compliance combi » Three power options: 24/31, 28/35 and 32/40 kW » High DHW capacity » 2” LCD display (Enerwa) » ± 1 degree heat sensitivity » 10 mm whole body insulation » Stainless steel DHW heat exchanger » Gas adaptive system » High savings with 1:10 modulation on 24/31 kW » Electronic control power pump (7,5 h/m) more stronger & quieter circulation » Both LPG and natural gas compatible » Low pressure safety » Automatic trouble shooting system » Low emission » Double NTC sensor system » Weekly adjustable digital room thermostats (optional) » Outdoor temperature sensor (optional) Enerwa 24/31 Enerwa 28/35 Enerwa 32/40 3 W NnEed by com mi er inu te iations are d var et al kW s iler All tec hn ic DH Wc 24 k ombi b o ing pa r lt/m 2.8 W flo w rate 1 The Features of Enerwa / EnerwaPlus 24 kW 3 kW GAS ADAPTIVE CONTROL LOWER ENERGY CONSUMPTION CONTINUOUS EFFICIENCY Gas Adaptive Control system can provide simultaneous control with its ionisation signal and gas valve. New moderated electronic card allows your combi boiler heating ratio to 1:10 by the support of electronic gas valve and new modulated fan system (an 24/31 kW). New Self adaptive system with the electronic gas valve regulates the accurate timing for the burning signal and provides the most efficient air / gas combination. ilers bo ariations a al v re nic kw 24 kW com ring bi pa mined by com ter de Compatible with LPG and NATURAL GAS All t ec h 24 LPG or NATURAL GAS Warmhaus boilers can supply you efficiency with natural gas and also LPG. SILENT ECONOMIC COMPACT DIMENSIONS SILENCE Very low electric consumption (maximum: 82 W). It fits even in narrow area with its compact dimensions. By the 10 mm cover isolation, Warmhaus gas boilers works in silence and avoids heat loss. W: 420 mm H: 725 mm D: 288 mm 6 SMART 3” LCD DISPLAY CONTINUOS HOT WATER WIDE INFORMATION DISPLAY LCD display shows the temperature of DHW, CH and system pressure on the same screen. ASYMETRIC HEAT EXCHANGER SYSTEM New generation heat exchanger provides high flow ratio with its wide asymetric water-channels by its own design plates. EFFECTIVE CIRCULATION INSTANT HOT WATER PRESSURE SENSITIVE BOILER EXCELLENT PROCESS PUMP WITH FREQUENCY CONVERTOR Bye the PRE-HEAT SYSTEM, the gas boilers keep DHW ready to use. Provides maximum efficiency by adjusting the altitude. 8 LITER EXPLOSION TANK The new generation expansion tank is able to provide 130-140 liters water to the system. High effeciency pump 7,5 mSS pump pressure. HIGH DHW CAPACITY High DHW power (31 kW) with plenty of hot water. • ΔT = 30 °C • 14,8 l/min WORKS UNDER LOW PRESSURE Works even at very low water pressure conditions. (only 0,15 bar = 1,5 l/min.) 7 Smart Processor’s Features of Enerwa / EnerwaPlus new design PriwaPlus 24 Priwa 24 NEW GENERATION STAINLESS STEEL CONDENSING HEAT EXCHANGER Single Coil Ferritic Stainless Steel (EN 1.4509 /AISI 441) * No parallel hydraulic circuits. * No brazing and manifold in the hydraulic circuit. * No hydraulic leakage risk Outdoor Temperature Sensor (optional) By the smart and accurate temperature regulations, Warmhaus combi boiler perceives the outside temperature changes, set the temperature itself and keeps you away from adjusting all the time Auto diagnosis system Digital error codes provide easy and faster solution by calling services to solve the problem. Thermostatic time-lock disables the gas boilers working in the unnecessary periods between 1 min to 10 mins. Controlled power boost Warmhaus gas boiler distributes the heat power depend on time (0-13 min) and decreases the gas consumption while increasing the utilization efficiency 10 XL XL A++ A+ A B C D E F G 52 dB 2015 A B C D E F G A A 24 kW A++ A+ A B C D E F G 52 dB 811/2013 A B C D E F G A A 24 kW 2015 811/2013 Altitude parameter; adjusted depending on the different altitudes and makes the burning more effective. By the B&P temperature regulation thermostats, you are able to manage weekly programs with the room thermostats. (optional). Warmhaus Gas Boilers are totally adaptable with the solar systems. Electronic system card allows the system to adapt your existing solar system by combining the hot water input. The system is also adaptable with the floor heating systems. It disables the overheating problem of the floor heating system and protects your boiler and installation. Warmhaus ErP-Energy-related Products INNOVATIVE AND ENVIRONMENTAL By the Innovative and environmental approach, Warmhaus combi boilers focus on less energy consumption, by its latest technology. Easy to Understand ErP Label Enerwa 24 ErP DIRECTIVE (2009/125 / CE) ErP (Energy-related Products) Directive, regulated by the European Union after the first successful step ErP in 2009, includes all the products consuming energy. Addressing to this directive, all the products sold in the EU after 26th September 2015, must have ErP sticker which shows these products are manufactured under the new technology, less consuming energy processes. In the heating system, all the air conditioning, refrigeration products have to be manufactured with the energy - related pumps and fans as of 1st August 2015. XL A++ A+ A B C D E F G A A B C D E F G A 24 kW 52 dB 2015 811/2013 The main points of ErP Directives until 2020 are; 20% reduced CO2 emissions on the atmosphere, 20% increase saving energy by the consumers, 20% increase on the efficiency of the all energy related products. The new sticker system of the European Union allows the consumers to see if the products are manufactured on the basis of ErP directives. Regarding to the ErP directives, these stickers has to show the energy consumptions, voice decibel and all the other performances of the products by its degrees. EnerwaPlus 24 XL A++ A+ A B C D E F G 52 dB 2015 A B C D E F G A A 24 kW 811/2013 11 118 208 Dimensions & Technical Specifications Connections 118 208 118 208 725 208 A B C D E F G H I J K 725 118 WARM CENTRAL HEATING FLOW DOMESTIC HOT WATER OUTLET C INLET B GAS D E 420 DOMESTIC HOT WATER INLET CENTRAL HEATING RETURN FILLING VALVE MANOMETER PRESSURE RELIEF VALVEFOUTLET DRAIN POINT G WARM CONDANSATE DRAIN H 230V 50HZ AC 74 A B 100 C I 65 148 65 65 D E F G PUMP FLOW H PRESSURE GRAPHIC I J External control via PWM 1 K 725 K J 40 30 C B 420 D E KEY 65 148 65 30 P/kPa Wilo-Yonos PARA KSL 15/7.0 I 8 4660/5 PWM1 A 7 80 n=1/min/%PWM 1 C B 420 D E 70 4210/15 PWM1 6 60 PWM1 5 3730/25 50 F G H 4 3240/35 PWM1 3 2750/45 PWM1 K 2 2260/55PWM1 J 1770/65 PWM1 1 0 0 PWM1 1290/75PWM1 800/85 100 0,40 65 136 100 288 65 40 K 230V 50HZ AC 74 94 Central Heating Flow Domestic Hot Water Outlet J Gas Inlet Domestic Hot Water Inlet Central Heating Return Filling Valve Manometer Pressure Relief Valve Outlet Drain Poınt Condensate Drain 136 : : : : : : : : : : F G H K 40 A B C D E F G H I J 725 A 725 288 74 ,8 148 1,21 ,6 65 65 2,02 40 30 20 10 94 118 136 A B AC D E208 F G H I J K 30 288 725 WARMHAUS PRIWA / ENERWA 94 118 208 ,4 I 0 13 TECHNICAL DATA UNIT Warmhaus CE certification Enerwa-ErP 24/31 & EnerwaPlus-ErP 24/31 Enerwa-ErP 28/35 & EnerwaPlus-ErP 28/35 CE-1015CR0544 :16 CE Gas Circuit Gas type Gas supply pressure mbar Inlet pressure (min÷max) mbar Gas Consumption at Maximum m³/h Gas Consumption at Minimum m³/h G20 G25 G31 G20 20 37 37 20 2,35* 2,81 0,90 2,97* 0,37* 0,43 0,10 0,39* *(Natural Gas G20) Heat Load (Hu=10,56 kWh/m3) Premix System Gas Adaptive Modulation Range Heat Exchanger Material Gas Adaptive 1:10 1:07 Stainless steel Stainless steel Efficiency (80/60 oC) Efficiency at Maximum Heat Output % 98,03 97,84 97,76 (50/30 oC) Efficiency at Maximum Heat Output % 105.11 105,34 103,63 97,88 105.0 Efficiency at 30% load at 36/30 °C % 108,29 108,38 108,29 107,54 Maximum heat input Qn kW 24,25 24,25 24,25 28,70 Minimum heat input Qn kW 3,5 3,5 2,8 3,75 Maximum Heat Output Pn (80/60 °C) kW 23,7 23,7 23,7 28 Minimum Heat Output Pn (80/60 °C) kW 3 3 2,5 3,5 Maximum Heat Output Pn (50/30 °C) kW 25 25 25 30 Minimum Heat Output Pn (50/30 °C) kW 3,6 3,6 2,9 3,90 Temperature selection range (min÷max) high temperature ºC 25÷80 25÷80 Temperature selection range (min÷max) low temperature ºC 25÷47 25÷47 Operating Pressure (Maximum) bar 3 3 Operating Pressure (Minimum) bar 0,5 0,5 Radiator Circuit Expansion tank useful volume bar 8 10 Pump pressure (at 1000 l/h flow rate) H2O 5,5 5,5 Pump pressure (at 500 l/h flow rate) H2O 7,8 7,8 Max. Pump Flow Rate ℓ/h 2400 2400 Maximum DHW Heat Input kW 31.15 35 Minimum DHW Heat Output kW 3,3 3,75 Max. Domestic Hot Water flow rate (Δt: 30 °C) ℓ/min. 14,8 16,30 Min. Domestic Hot Water flow rate (for the DHW function activation) ℓ/min. 1,5 1,5 Maximum water pressure bar 10 10 Minimum water pressure bar 0,5 1,1 Temperature adjustment range ºC 35 - 60 35 - 60 V AC–50 Hz 230 V +%10; -%15 230 V +%10; -%15 Watt 82 82 IP IPX5D IPX5D Domestic Hot Water Circuit Electricity Circuit Electricity Supply Electricity Consumption Protection Index Exhaust Gas Circuit Flue temperature (Qn) °C (80/60 °C) Exhaust gas temperature (Min. / Max.) ºC 69,3 /70,5 64,6 / 70,2 59,9 / 69,7 60,8 / 66,1 (50/30 °C) Exhaust gas temperature (Min. / Max.) ºC 48,5 / 50,5 47,7 / 49,4 47,0 / 50,5 44,5 / 44,5 ºC 70 70 70 70 Maximum exhaust gas temperature [Maximum DHW mode] NOx Weighted value of Nox (GCV) Class 5 5 mg/kWh 20 19 31 Flue mass flow rate (60/80°C - Qn) Nominal/Minimum g/s 11,13 /1,6 13,23 / 1,72 Flue mass flow rate (60/80°C - Qn) [Maximum DHW mode] g/s 14,3 15,82 General Dimensions (H x W X D) mm Hydraulic Group Material 725 x 420 x 288 Brass Brass Net Weight kg 31,4 32 Packed Device Weight kg 34,6 35,2 Type Category 14 725 x 420 x 288 C 13, C 33, C53, C83 C 13, C 33, C53, C83 I2H (G20=20 mbar), I3P (G31=37 mbar) I2H (G20=20 mbar), I3P (G31=37 mbar) Optional Remote Controls Wired Remote Controls Wireless Remote Controls External Sensor TA1 E20 RC07 RC08 KIT RFRC03 Combi boilers remote controls with room thermostat Model RC07 RC08 KIT RFRC03 External Sensor Model Code Connection Type Weekly Programmable Control Type Features WT-07 Wired P Modulated (Entry model) 4 button, small display WT-08 Wired P Modulated (Mid model) 10 button, wide display WT-03 Wireless P Modulated (Mid model) 10 button, wide display Modulation according to outdoor air temperature Automatic operation with combi-boiler connection and replacement with parameter WDHS-01 Wired 15 24/31 - 28/35 - 32/40 kW Premix System Condensing - ErP Combi Gas Boilers Enerwa / EnerwaPlus