Preview only show first 10 pages with watermark. For full document please download

English Forest Multi Rf

   EMBED


Share

Transcript

1 MULTI RF MANUAL CONTENT Forest Multi remote – 5201.00.X64X 2 Forest Multi wall switch RF – 5201.00.1470 4 Forest Multi wall switch LED – 5201.00.1480 4 Forest Multi receiver click-on – 5201.00.1362 5 Forest Shuttle S / L receiver programming – 5232.00.0000/1 5 Forest Multi receiver / wall switch for Shuttle M – 5201001360/1361 6 Forest FMS/BCS Multi receiver – 5201.01.1500 - programming remote - wiring diagram 6 7 Tubular motor with build in receiver and electronic limit setting - wiring diagram - programming remote - setting end limits 8 9 10 BS double shaft motor 24V – 3648.00.0000 - programming remote - setting end limits 12 13 08/2014 WDOC MULTI REMOTE www.forestgroup.nl v1.91 2 FOREST MULTI REMOTE – 520100X46X TECHNICAL SPECIFICATION: ● 3V battery CR2430 ● battery life < 3 years ● frequency 433.92MHz ● transmit power max. 10mW ● transmit range indoors max. 30mtr ● working temperature -10°C - +50°C ● modes: manual, timer and dynamic timer (15 minutes + and -) ● each channel can control up to 20 receivers / motors selected channel manual/auto/dynamic mode open/up button mode button stop button close/down button time button P2 (LEARN) button channel +/battery slide (CR2430) SET TIME press mode to set mode to manual ‘man’ on display press time for ~7sec. press buttons to → 2 digits will blink change time press time to toggle between hours/minutes press time ~7sec. until all digits stop blinking press time once more to finish and start clock SET TIMER (EACH CHANNEL SEPARATE): BEFORE SETTING THE TIMER(S), SET THE CLOCK! press mode to set mode to auto or dynamic select channel press buttons to change close time press time to toggle between hours/minutes 08/2014 WDOC MULTI REMOTE press time for ~7sec. → hour digits will blink NOTE: time between button presses max. 10 seconds press buttons to change open time press time to toggle between hours/minutes press mode to switch to close time press time for ~7sec. set to mode until digits stop auto or dynamic blinking → finished www.forestgroup.nl v1.91 3 FOREST MULTI REMOTE – 520100X46X MODE EXPLANATION:  Mode manual (man): remote can only be used manually. Timer function is switched off.  Mode automatic (auto): timer is switched on, only for the selected channel. Select channel 00 (all channels) to engage on all timers.  Mode dynamic ( ): same as automatic mode, open and close time will vary + and – 15 minutes. FEATURES:  When channel select is set to channel 00, all the channels 1 to 15 will respond to open and close.  Default timer setting for every channel is: open 06:30AM, close 5:30PM.  Dynamic mode: timer will vary open and close time between + and – 15 minutes. The first day dynamic mode is used the time will not vary. FREQUENT ASKED QUESTIONS: ● Q: Clock doesn’t start running after setting the time. A: Press time button on the back once more. ● Q: I can’t succeed setting the time or the timer. A: The interval between pressing different button must be within 10 seconds. ● Q: When I set a timer, the display shows Er:01 A: Time between open-time and close-time must be more than 30 minutes apart. ● Q: Timer only works on one channel. A: Only the selected channel will work as a timer. Use channel 00 to turn on all timers (all channels). ● Q: I can’t succeed programming a remote / wall switch RF to a receiver A: During programming, keep the remote / wall switch RF close to the receiver (max 0,5 mtr) COLOURS: 520100 1460 520100 1461 520100 1461-wl 520100 3461 520100 3461-wl 520100 6460 520100 6460-wl 520100 6461 520100 6461-wl white gloss white mat white mat without logo grey mat grey mat without logo black gloss black gloss without logo black mat black mat without logo BATTERY EMPTY: After changing the battery, only the time must be set. Programmed receivers and timers will stay in memory of remote. Please follow the local regulations for disposal of the empty battery. 08/2014 WDOC MULTI REMOTE www.forestgroup.nl v1.91 4 FOREST MULTI WALL SWITCH RF - 5201001470 TECHNICAL SPECIFICATION: ● 3V battery CR2032 ● battery life < 3 years ● frequency 433.92MHz ● transmit power max. 10mW ● transmit range indoor max. 30mtr ● working temperature -10°C - +50°C ● each channel can control up to 20 receivers P2 buttons (for programming tubular motor) OPEN/UP button STOP button CLOSE/DOWN button channel A channel B battery CR2032 BATTERY EMPTY: After changing the battery, programmed receivers will stay in memory of remote. Please follow the local regulations for disposal of the empty battery. FOREST MULTI WALL SWITCH LED- 5201001480 TECHNICAL SPECIFICATION: ● 12V battery type 27A ● battery life < 3 years ● frequency 433.92MHz ● transmit power max. 10mW ● transmit range indoor max. 30mtr ● working temperature -10°C - +50°C ● each channel can control up to 20 receivers OPEN/UP button STOP button CLOSE/DOWN button + channel A channel B P2 buttons (for programming tubular motor) BATTERY EMPTY: After changing the battery, programmed receivers will stay in memory of remote. Please follow the local regulations for disposal of the empty battery. 08/2014 WDOC MULTI REMOTE www.forestgroup.nl v1.91 5 FOREST MULTI RECEIVER CLICK ON – 5201001362 TECHNICAL SPECIFICATION:     powered by Shuttle M connect to port 1 of the Forest Shuttle M working temperature -10°C - +50°C controlled by Forest Multi Remote and Forest Multi Wall Switch RF control led PROGRAMMING REMOTE / WALL SWITCH TO RECEIVER: press program button led will light up hold the remote within 0,5 mtr from receiver. Select channel (1-15) and press open button program button CANCEL ONE CHANNEL OF REMOTE / WALL SWITCH DELETE ALL PREVIOUS PROGRAMMED REMOTES / WALL SWITCHES: press program button led will light up press and hold the program button for 10 seconds until led starts blinking select channel and press close button led blinks 3 times and will go off led will blink and will go off FOREST SHUTTLE S / L RECEIVER PROGRAMMING To programming a RF remote to a Shuttle S / L, press configuration button 3 times. LED3 is ON. Keep the button pressed for 4 seconds, LED will start blinking for 10 seconds. In these 10 seconds press OPEN button on remote to program the channel to the Shuttle. Same procedure, but press CLOSE instead of OPEN, will erase the programmed channel. configuration button 08/2014 WDOC MULTI REMOTE www.forestgroup.nl v1.91 6 5201001360 / 1361 5201011500 TECHNICAL SPECIFICATION SHUTTLE M RECEIVER: ● powered by Shuttle M ● can also be used as wall switch ● cable 0,5mtr → 5201001360 ● cable 3,5mtr → 5201001361 ● connect to port 1 of the Forest Shuttle M ● working temperature -10°C - +50°C ● controlled by Forest Multi Remote and Forest Multi Wall Switch RF TECHNICAL SPECIFICATION FMS/BCS RECEIVER: ● power 230Vac – 500W ● controls one motor ● can also be used as wall switch ● terminal max 2,5mm² ● working temperature -10°C - +50°C P2 program button control led OPEN/UP button STOP button CLOSE/DOWN button PROGRAMMING REMOTE / WALL SWITCH TO RECEIVER: CANCEL ONE CHANNEL OF REMOTE / WALL SWITCH press program button, led will blink press program button, led will blink press stop button press stop button hold the remote within 0,5 mtr from receiver. Select channel (1-15) and press OPEN button: select channel and press CLOSE button: led blinks 3 times and will go off led will blink and will go off 08/2014 WDOC MULTI REMOTE www.forestgroup.nl DELETE ALL PREVIOUS PROGRAMMED REMOTES / WALL SWITCHES: press stop and close button of receiver for ~6 sec. led will blink and will go off v1.91 7 WIRING DIAGRAM FOREST FMS / TUBULAR MOTOR TO 5201011500 08/2014 WDOC MULTI REMOTE www.forestgroup.nl v1.91 8 TUBULAR MOTOR BUILD-IN RECEIVERAND ELECTRONIC LIMIT SETTING TECHNICAL SPECIFICATION: ● 3416600099 – 6Nm, 33rpm, build-in receiver, electronic limit setting (110V) ● 3416600110 – 3Nm, 28rpm, build-in receiver, mechanical limit setting (230V) ● 3416600112 – 6Nm, 28rpm, build-in receiver, electronic limit setting (230V) ● 3416600116 – 13Nm, 14rpm, build-in receiver, electronic limit setting (230V) ● 3416600117 – 6Nm, 20rpm, build-in receiver, electronic limit setting,QUIET (230V) ● max. running time 4 min. ● protection degree IP44 (230V), class B (110V) ● has to be used with Multi remote and/or Multi wall switch RF IMPORTANT 230V: use only wires BROWN (phase), BLUE (neutral) and GREEN/YELLOW (earth). The additional two wires (black and red) are for connecting the optional obstruction sensor. Make sure these two wires are not connected together and do NOT make contact with the power wires. 110V: use only wires BLACK (phase), WHITE (neutral) and GREEN (earth). 230Vac: PHASE L NEUTRAL EARTH brown blue yellow/green 08/2014 WDOC MULTI REMOTE www.forestgroup.nl v1.91 9 TUBULAR MOTOR BUILD-IN MULTI RECEIVER AND ELECTRONIC LIMIT SETTING NOTE: during programming, keep the remote or wireless wall switch within 2 mtr from the receiver/motor PROGRAMMING REMOTE / WALL SWITCH TO TUBULAR MOTOR: ADD MORE REMOTES / WALL SWITCHES / CHANNELS TO TUBULAR MOTOR CANCEL ALL REMOTES OR WALL SWITCHES first select the desired channel first select the desired channel first select the programmed channel press button on motor, motor will turn short to acknowledge ①st remote: press P2 button two times press P2 button one time 2x P2 1x P2 ① within 6 seconds: press P2 button two times ②nd remote: press P2 button one time 2x P2 press STOP button one time 1x P2 1x STOP ② press OPEN-button one time motor will turn to acknowledge press P2 button one time 1x P2 1x OPEN motor will turn to acknowledge motor will turn to acknowledge to add another channel on the same remote: 1.select the programmed channel, 2.press button P2 of remote two times, 3.select desired channel and press P2 button motor will turn to acknowledge CHANGING DIRECTION OF ROTATION To change the direction of rotation, keep green button on motor pressed for 7 sec, until motor turns to acknowledge. 08/2014 WDOC MULTI REMOTE www.forestgroup.nl v1.91 10 TUBULAR MOTOR BUILD IN MULTI RECEIVER AND ELECTRONIC LIMIT SETTING ADJUSTING UPPER AND LOWER END LIMITS: IMPORTANT: - when more motors are programmed to one channel, end limits of all motors will be adjusted - during programming, keep the remote or wireless wall switch within 2 mtr from the receiver/motor press P2 button one time press OPEN button one time 1x P2 press P2 button one time 1x P2 1x OPEN motor will turn to acknowledge adjust to UPPER position press STOP button when required height is reached. Press STOP button 5 times slowly for 1 seconds to confirm 5x STOP (slowly) motor will turn to acknowledge adjust to LOWER limit press STOP button when required height is reached. Press STOP button 5 times slowly for 1 seconds to confirm 5x STOP (slowly) motor will turn to acknowledge, limits have been set successfully. 08/2014 WDOC MULTI REMOTE www.forestgroup.nl v1.91 11 TUBULAR MOTOR BUILD IN MULTI RECEIVER AND ELECTRONIC LIMIT SETTING CANCELLATION OF UPPER AND LOWER END LIMITS: IMPORTANT: When cancelling end limits, all motors programmed to that channel will be cancelled press P2 button one time press CLOSE button one time press P2 button one time 1x P2 1x P2 motor will turn to acknowledge, limits has been set successfully. REVERSE DIRECTION SETTING: When motor is not running, press button on motor for ~ 7 seconds, until motor turns to acknowledge. 08/2014 WDOC MULTI REMOTE www.forestgroup.nl v1.91 12 BS 24V DOUBLE SHAFT MOTOR - 36.4800.0000 BUILD-IN RECEIVER - ELECTRONIC LIMIT SETTING TECHNICAL SPECIFICATION: ● 24Vdc, 16Watt ● nom. 0.8Nm – max. 1.0Nm ● 34 rpm ● max. running time 7 min. ● max. curtain weight 4 kg ● max. 5 cord rolls ● has to be used with Multi remote and/or Multi wall switch RF ● only to be used in Forest BS system and with Forest power supply for BS motor IMPORTANT: WHEN USING THE QUICK LOCK CORD ROLL, BE SURE TO LOCK THE CORD BEFORE USING THE MOTOR PROGRAMMING REMOTE TO BS MOTOR: REMOVE PROGRAMMED CHANNEL CHANGE MOTOR DIRECTION first select the desired channel first select the desired channel first select the desired channel switch on power to the motor: switch on power to the motor: switch on power to the motor: motor will jog to acknowledge: motor will jog to acknowledge: motor will jog to acknowledge: within 10 seconds after jog, press OPEN button on remote within 10 seconds after jog, press STOP button on remote within 10 seconds after jog, press CLOSE button on remote motor will jog to acknowledge: motor will jog to acknowledge: motor will jog to acknowledge: NOTE: if you need to start over, switch off the power and wait at least 20 seconds before switching in the power 08/2014 WDOC MULTI REMOTE www.forestgroup.nl v1.91 13 BS 24V DOUBLE SHAFT MOTOR - 36.4800.0000 BUILD-IN RECEIVER - ELECTRONIC LIMIT SETTING SET UPPER END LIMIT SET LOWER END LIMIT DELETE LIMITS press P2 button once, motor will jog to acknowledge: press P2 button once, motor will jog to acknowledge: press P2 button twice, motor will jog to acknowledge: 1xP2 1xP2 2xP2 press OPEN button on remote, motor will jog to acknowledge: press CLOSE button on remote, motor will jog to acknowledge: press OPEN button on remote, motor will jog to acknowledge: 1x 1x 1x press P2 button once, motor will jog to acknowledge: press P2 button once, motor will jog to acknowledge: DELETE ALL MEMORY 1xP2 1xP2 press P2 button twice motor will jog to acknowledge: 2xP2 adjust desired upper end limit and press P2 to save the upper limit: adjust desired lower end limit and press P2 to save the lower limit 1x P2 1x P2 press CLOSE button on remote, motor will jog twice to acknowledge motor will jog to acknowledge: motor will jog to acknowledge: 1x 08/2014 WDOC MULTI REMOTE www.forestgroup.nl v1.91