Transcript
1
MULTI RF MANUAL CONTENT
Forest Multi remote – 5201.00.X64X
2
Forest Multi wall switch RF – 5201.00.1470
4
Forest Multi wall switch LED – 5201.00.1480
4
Forest Multi receiver click-on – 5201.00.1362
5
Forest Shuttle S / L receiver programming – 5232.00.0000/1
5
Forest Multi receiver / wall switch for Shuttle M – 5201001360/1361
6
Forest FMS/BCS Multi receiver – 5201.01.1500 - programming remote - wiring diagram
6 7
Tubular motor with build in receiver and electronic limit setting - wiring diagram - programming remote - setting end limits
8 9 10
BS double shaft motor 24V – 3648.00.0000 - programming remote - setting end limits
12 13
08/2014 WDOC MULTI REMOTE
www.forestgroup.nl
v1.91
2
FOREST MULTI REMOTE – 520100X46X TECHNICAL SPECIFICATION: ● 3V battery CR2430 ● battery life < 3 years ● frequency 433.92MHz ● transmit power max. 10mW
● transmit range indoors max. 30mtr ● working temperature -10°C - +50°C ● modes: manual, timer and dynamic timer (15 minutes + and -) ● each channel can control up to 20 receivers / motors
selected channel
manual/auto/dynamic mode open/up button
mode button
stop button close/down button
time button P2 (LEARN) button
channel +/battery slide (CR2430) SET TIME
press mode to set mode to manual ‘man’ on display
press time for ~7sec. press buttons to → 2 digits will blink change time
press time to toggle between hours/minutes
press time ~7sec. until all digits stop blinking
press time once more to finish and start clock
SET TIMER (EACH CHANNEL SEPARATE):
BEFORE SETTING THE TIMER(S), SET THE CLOCK!
press mode to set mode to auto or dynamic
select channel
press buttons to change close time
press time to toggle between hours/minutes
08/2014 WDOC MULTI REMOTE
press time for ~7sec. → hour digits will blink
NOTE: time between button presses max. 10 seconds
press buttons to change open time
press time to toggle between hours/minutes
press mode to switch to close time
press time for ~7sec. set to mode until digits stop auto or dynamic blinking → finished www.forestgroup.nl
v1.91
3
FOREST MULTI REMOTE – 520100X46X MODE EXPLANATION: Mode manual (man): remote can only be used manually. Timer function is switched off. Mode automatic (auto): timer is switched on, only for the selected channel. Select channel 00 (all channels) to engage on all timers. Mode dynamic ( ): same as automatic mode, open and close time will vary + and – 15 minutes.
FEATURES: When channel select is set to channel 00, all the channels 1 to 15 will respond to open and close. Default timer setting for every channel is: open 06:30AM, close 5:30PM. Dynamic mode: timer will vary open and close time between + and – 15 minutes. The first day dynamic mode is used the time will not vary.
FREQUENT ASKED QUESTIONS: ● Q: Clock doesn’t start running after setting the time. A: Press time button on the back once more. ● Q: I can’t succeed setting the time or the timer. A: The interval between pressing different button must be within 10 seconds. ● Q: When I set a timer, the display shows Er:01 A: Time between open-time and close-time must be more than 30 minutes apart. ● Q: Timer only works on one channel. A: Only the selected channel will work as a timer. Use channel 00 to turn on all timers (all channels). ● Q: I can’t succeed programming a remote / wall switch RF to a receiver A: During programming, keep the remote / wall switch RF close to the receiver (max 0,5 mtr)
COLOURS: 520100 1460 520100 1461 520100 1461-wl 520100 3461 520100 3461-wl 520100 6460 520100 6460-wl 520100 6461 520100 6461-wl
white gloss white mat white mat without logo grey mat grey mat without logo black gloss black gloss without logo black mat black mat without logo
BATTERY EMPTY: After changing the battery, only the time must be set. Programmed receivers and timers will stay in memory of remote. Please follow the local regulations for disposal of the empty battery.
08/2014 WDOC MULTI REMOTE
www.forestgroup.nl
v1.91
4
FOREST MULTI WALL SWITCH RF - 5201001470 TECHNICAL SPECIFICATION: ● 3V battery CR2032 ● battery life < 3 years ● frequency 433.92MHz ● transmit power max. 10mW
● transmit range indoor max. 30mtr ● working temperature -10°C - +50°C ● each channel can control up to 20 receivers
P2 buttons (for programming tubular motor)
OPEN/UP button STOP button CLOSE/DOWN button
channel A
channel B
battery CR2032
BATTERY EMPTY: After changing the battery, programmed receivers will stay in memory of remote. Please follow the local regulations for disposal of the empty battery.
FOREST MULTI WALL SWITCH LED- 5201001480 TECHNICAL SPECIFICATION: ● 12V battery type 27A ● battery life < 3 years ● frequency 433.92MHz ● transmit power max. 10mW
● transmit range indoor max. 30mtr ● working temperature -10°C - +50°C ● each channel can control up to 20 receivers
OPEN/UP button STOP button CLOSE/DOWN button
+
channel A
channel B
P2 buttons (for programming tubular motor)
BATTERY EMPTY: After changing the battery, programmed receivers will stay in memory of remote. Please follow the local regulations for disposal of the empty battery. 08/2014 WDOC MULTI REMOTE
www.forestgroup.nl
v1.91
5
FOREST MULTI RECEIVER CLICK ON – 5201001362 TECHNICAL SPECIFICATION:
powered by Shuttle M connect to port 1 of the Forest Shuttle M working temperature -10°C - +50°C controlled by Forest Multi Remote and Forest Multi Wall Switch RF
control led PROGRAMMING REMOTE / WALL SWITCH TO RECEIVER:
press program button led will light up hold the remote within 0,5 mtr from receiver. Select channel (1-15) and press open button
program button
CANCEL ONE CHANNEL OF REMOTE / WALL SWITCH
DELETE ALL PREVIOUS PROGRAMMED REMOTES / WALL SWITCHES:
press program button led will light up
press and hold the program button for 10 seconds until led starts blinking
select channel and press close button
led blinks 3 times and will go off
led will blink and will go off
FOREST SHUTTLE S / L RECEIVER PROGRAMMING
To programming a RF remote to a Shuttle S / L, press configuration button 3 times. LED3 is ON. Keep the button pressed for 4 seconds, LED will start blinking for 10 seconds. In these 10 seconds press OPEN button on remote to program the channel to the Shuttle. Same procedure, but press CLOSE instead of OPEN, will erase the programmed channel.
configuration button 08/2014 WDOC MULTI REMOTE
www.forestgroup.nl
v1.91
6
5201001360 / 1361 5201011500 TECHNICAL SPECIFICATION SHUTTLE M RECEIVER: ● powered by Shuttle M ● can also be used as wall switch ● cable 0,5mtr → 5201001360 ● cable 3,5mtr → 5201001361 ● connect to port 1 of the Forest Shuttle M ● working temperature -10°C - +50°C ● controlled by Forest Multi Remote and Forest Multi Wall Switch RF
TECHNICAL SPECIFICATION FMS/BCS RECEIVER: ● power 230Vac – 500W ● controls one motor ● can also be used as wall switch ● terminal max 2,5mm² ● working temperature -10°C - +50°C
P2 program button
control led
OPEN/UP button STOP button CLOSE/DOWN button
PROGRAMMING REMOTE / WALL SWITCH TO RECEIVER:
CANCEL ONE CHANNEL OF REMOTE / WALL SWITCH
press program button, led will blink
press program button, led will blink
press stop button
press stop button
hold the remote within 0,5 mtr from receiver. Select channel (1-15) and press OPEN button:
select channel and press CLOSE button:
led blinks 3 times and will go off
led will blink and will go off
08/2014 WDOC MULTI REMOTE
www.forestgroup.nl
DELETE ALL PREVIOUS PROGRAMMED REMOTES / WALL SWITCHES:
press stop and close button of receiver for ~6 sec.
led will blink and will go off
v1.91
7
WIRING DIAGRAM FOREST FMS / TUBULAR MOTOR TO 5201011500
08/2014 WDOC MULTI REMOTE
www.forestgroup.nl
v1.91
8
TUBULAR MOTOR BUILD-IN RECEIVERAND ELECTRONIC LIMIT SETTING TECHNICAL SPECIFICATION: ● 3416600099 – 6Nm, 33rpm, build-in receiver, electronic limit setting (110V) ● 3416600110 – 3Nm, 28rpm, build-in receiver, mechanical limit setting (230V) ● 3416600112 – 6Nm, 28rpm, build-in receiver, electronic limit setting (230V) ● 3416600116 – 13Nm, 14rpm, build-in receiver, electronic limit setting (230V) ● 3416600117 – 6Nm, 20rpm, build-in receiver, electronic limit setting,QUIET (230V) ● max. running time 4 min. ● protection degree IP44 (230V), class B (110V) ● has to be used with Multi remote and/or Multi wall switch RF
IMPORTANT 230V: use only wires BROWN (phase), BLUE (neutral) and GREEN/YELLOW (earth). The additional two wires (black and red) are for connecting the optional obstruction sensor. Make sure these two wires are not connected together and do NOT make contact with the power wires. 110V: use only wires BLACK (phase), WHITE (neutral) and GREEN (earth).
230Vac: PHASE L NEUTRAL EARTH
brown blue yellow/green
08/2014 WDOC MULTI REMOTE
www.forestgroup.nl
v1.91
9
TUBULAR MOTOR BUILD-IN MULTI RECEIVER AND ELECTRONIC LIMIT SETTING NOTE: during programming, keep the remote or wireless wall switch within 2 mtr from the receiver/motor PROGRAMMING REMOTE / WALL SWITCH TO TUBULAR MOTOR:
ADD MORE REMOTES / WALL SWITCHES / CHANNELS TO TUBULAR MOTOR
CANCEL ALL REMOTES OR WALL SWITCHES
first select the desired channel
first select the desired channel
first select the programmed channel
press button on motor, motor will turn short to acknowledge
①st remote: press P2 button two times
press P2 button one time
2x P2
1x P2
①
within 6 seconds: press P2 button two times
②nd remote: press P2 button one time
2x P2
press STOP button one time
1x P2 1x STOP ②
press OPEN-button one time
motor will turn to acknowledge
press P2 button one time
1x P2 1x OPEN
motor will turn to acknowledge
motor will turn to acknowledge to add another channel on the same remote: 1.select the programmed channel, 2.press button P2 of remote two times, 3.select desired channel and press P2 button motor will turn to acknowledge
CHANGING DIRECTION OF ROTATION To change the direction of rotation, keep green button on motor pressed for 7 sec, until motor turns to acknowledge. 08/2014 WDOC MULTI REMOTE
www.forestgroup.nl
v1.91
10
TUBULAR MOTOR BUILD IN MULTI RECEIVER AND ELECTRONIC LIMIT SETTING ADJUSTING UPPER AND LOWER END LIMITS: IMPORTANT:
- when more motors are programmed to one channel, end limits of all motors will be adjusted - during programming, keep the remote or wireless wall switch within 2 mtr from the receiver/motor
press P2 button one time
press OPEN button one time
1x P2
press P2 button one time
1x P2 1x OPEN
motor will turn to acknowledge
adjust to UPPER position
press STOP button when required height is reached. Press STOP button 5 times slowly for 1 seconds to confirm
5x STOP (slowly)
motor will turn to acknowledge
adjust to LOWER limit
press STOP button when required height is reached. Press STOP button 5 times slowly for 1 seconds to confirm
5x STOP (slowly)
motor will turn to acknowledge, limits have been set successfully.
08/2014 WDOC MULTI REMOTE
www.forestgroup.nl
v1.91
11
TUBULAR MOTOR BUILD IN MULTI RECEIVER AND ELECTRONIC LIMIT SETTING CANCELLATION OF UPPER AND LOWER END LIMITS: IMPORTANT: When cancelling end limits, all motors programmed to that channel will be cancelled
press P2 button one time
press CLOSE button one time
press P2 button one time
1x P2
1x P2
motor will turn to acknowledge, limits has been set successfully.
REVERSE DIRECTION SETTING: When motor is not running, press button on motor for ~ 7 seconds, until motor turns to acknowledge.
08/2014 WDOC MULTI REMOTE
www.forestgroup.nl
v1.91
12
BS 24V DOUBLE SHAFT MOTOR - 36.4800.0000 BUILD-IN RECEIVER - ELECTRONIC LIMIT SETTING TECHNICAL SPECIFICATION: ● 24Vdc, 16Watt ● nom. 0.8Nm – max. 1.0Nm ● 34 rpm ● max. running time 7 min. ● max. curtain weight 4 kg ● max. 5 cord rolls ● has to be used with Multi remote and/or Multi wall switch RF ● only to be used in Forest BS system and with Forest power supply for BS motor IMPORTANT: WHEN USING THE QUICK LOCK CORD ROLL, BE SURE TO LOCK THE CORD BEFORE USING THE MOTOR PROGRAMMING REMOTE TO BS MOTOR:
REMOVE PROGRAMMED CHANNEL
CHANGE MOTOR DIRECTION
first select the desired channel
first select the desired channel
first select the desired channel
switch on power to the motor:
switch on power to the motor:
switch on power to the motor:
motor will jog to acknowledge:
motor will jog to acknowledge:
motor will jog to acknowledge:
within 10 seconds after jog, press OPEN button on remote
within 10 seconds after jog, press STOP button on remote
within 10 seconds after jog, press CLOSE button on remote
motor will jog to acknowledge:
motor will jog to acknowledge:
motor will jog to acknowledge:
NOTE: if you need to start over, switch off the power and wait at least 20 seconds before switching in the power 08/2014 WDOC MULTI REMOTE
www.forestgroup.nl
v1.91
13
BS 24V DOUBLE SHAFT MOTOR - 36.4800.0000 BUILD-IN RECEIVER - ELECTRONIC LIMIT SETTING SET UPPER END LIMIT
SET LOWER END LIMIT
DELETE LIMITS
press P2 button once, motor will jog to acknowledge:
press P2 button once, motor will jog to acknowledge:
press P2 button twice, motor will jog to acknowledge:
1xP2
1xP2
2xP2
press OPEN button on remote, motor will jog to acknowledge:
press CLOSE button on remote, motor will jog to acknowledge:
press OPEN button on remote, motor will jog to acknowledge:
1x
1x
1x press P2 button once, motor will jog to acknowledge:
press P2 button once, motor will jog to acknowledge: DELETE ALL MEMORY
1xP2
1xP2 press P2 button twice motor will jog to acknowledge: 2xP2
adjust desired upper end limit and press P2 to save the upper limit:
adjust desired lower end limit and press P2 to save the lower limit 1x P2
1x P2
press CLOSE button on remote, motor will jog twice to acknowledge
motor will jog to acknowledge:
motor will jog to acknowledge:
1x