Transcript
EO-YMeKaszh OV 2.0
Generated on 10/17/2017
Product specification
EO-YMeKaszh OV 2.0 Article group 10205
ELDTRAFFIC EO-YMeKaszh OV 2.0 is a halogen-free power cable for public lighting. The conductors are either bare, solid, electrolytic copper conforming to IEC 60228 class 1, or bare, stranded electrolytic copper conforming to IEC 60228 class 2, depending on their cross sectional area size. ELDTRAFFIC EO-YMeKaszh OV 2.0 cables have a braid of galvanized steel wires with an underlying protective earth of tinned copper that provides mechanical protection and excellent flexibility, which is beneficial during installation. ELDTRAFFIC EO-YMeKaszh OV 2.0 is waterproof and chemical resistant. This makes the cable suitable for almost any soil type. Eldra has further improved the stripability of the cable and as a result, substantially less force is required to remove the outer jacket and the cable can therefore be installed more quickly.
Extra information Available as standard with grey outer jacket with four green stripes. This makes it easily recognizable in the installation. PE Conductor With conductor cross sections of up to 16 mm² the cross sectional area of the protective earth matches that of the conductors. With a conductor cross section of 25 mm² the cross section of the protective earth is 16 mm².
Properties - halogen-free - suitable for continuous conductor temperature of 90°C - mechanical protection provided by steel wire braiding - largely chemical resistant - no water penetration - easy to strip - KEMA-KEUR quality mark Product specifications Protective conductor
no
Halogen free (acc. EN 60754-1/2)
yes
Flame retardant
No
Low smoke (acc. EN 61034-2)
yes
Circuit integrity
No
Insulation integrity
No
Standardization
K162-4
Standardization conductor material
IEC 60228
Conductor material
Cu, bare
Shape of conductor
Round
Number of cores
4
Core insulation
XLPE (VPE)
Product specifications Core identification
HD 308 S2
Material inner sheath
PE (polyethylene)
Inner sheath thickness (mm)
0.8
Concentric conductor
None
Earthscreen construction
Braiding + stranded wire
Armouring
yes
Armouring/reinforcement
Braiding + fleece tape
Lead sheath
no
Material outer sheath
Polyolefin
Outer sheath thickness (mm)
1.8
Colour outer sheath
Grey with four green stripes
Nominal voltage U0 (kV)
0.6
Nominal voltage U (kV)
1.0
Test voltage (kV)
3.5
Max. conductor temperature (°C)
90
Permitted cable outer temperature, in movement (°C)
-20 / 70
Permitted cable outer temperature, fixed (°C)
-40 / 80
max. short-circuit temperature conductor (°C)
250
Screen
yes
Drain wire
yes
Part nr.
Cable
Weight (kg/m) Ø (mm)
14196-1
4 x 2,5 mm2 Grey with four green stripes
0,3166
15,4
14197-1
4 x 4 mm2 Grey with four green stripes
0,4139
16,8
14198-1
4 x 6 mm2 Grey with four green stripes
0,5409
18,0
14199-1
4 x 10 mm2 Grey with four green stripes
0,8351
21,3