Transcript
EPD-240 240W. POWER AMPLIFIER - Class-D
POWER PROT
POWER AMPLIFIER
CLIP
CLASS-D
ON
INPUT
OFF
OUTPUT
CH1
CAUTION
AVISO
RISK OF ELECTRIC SHOCK DO NOT OPEN RIESGO DE CHOQUE ELECTRICO NO ABRIR EN TENSION
24VDC IN 110-230VAC 50/60Hz
VOLUME MASTER
LINE INPUT
CONFIG SELECTION
CH1
EPD-240 Amplificador de Potencia Power Amplifier
OFF
SPEAKER OUTPUT
1 2 3 4
ON
STANDBY: ON Shut down 1-2 OFF Auto standby ON
20-20KHz
3-4 OFF 80-20KHz HIGH PASS FILTER
DESCRIPTION 240W RMS power amplifier focused on applications for public address systems and professional audio. The use of digital signal processors as well as Class-D power amplifiers represent a technological advancement and a substantial increase in its performance. The equipment includes two power supply inputs: the main one for 110-230 VAC and an input for batteries (24 VDC). This enables the possibility of keeping the equipment operative during power cuts of the main AC input. It includes an electronic protection system against overcharge, short circuits and excessive heating. Besides, it includes an energy savings system (STANDBY mode) that automatically activates two minutes after detecting a lack of an input signal. Both its mechanic and electronic design are based on functionality, robustness and reliability criteria required for any sound application. Thanks to its standard dimensions (19'' standard, 1U), the equipment can be associated with UDE equipment and other elements such as audio sources, preamplifiers; among others. As a result we obtain a compact and uniform set with an important space-saving design. Its forced horizontal ventilation system allows it to be assembled in a rack by using its integrated mounting brackets.
FEATURES - Rated power output (L100V) - Rated power output (8 ): - Outputs: - Distortion (1kHz/-3dBu,100W): - Selectable frequency response:
240W RMS 210W RMS 8 / L100V. Lower than 0,1%. 20 Hz. to 20 KHz. 80 Hz. to 20 KHz. 0,775 V. (0 dBu). - Input sensitivity: - Input impedance: 10 k . - S/N ratio: >80dB 0 - 100%. - Master volume: - Maximum power consumption: 300 W. - Main power supply: 110 - 230 VAC (50/60 Hz). - Battery power supply: 24 VDC - max. 24 A. - Weight: 4,5 Kg.
UNION DESARROLLOS ELECTRONICOS Barcelona Avda. BARCELONA, 24 08970 - SANT JOAN DESPÍ BARCELONA - ESPAÑA
1U - Rack 19”
DIMENSIONS IN MILLIMETRES
482 44
FRONT PANEL
400 SIDE PANEL
UDE reserves the right to modify the technical characteristics of its products without previous notice Tel: +34 93 477 28 54 Fax: +34 93 261 17 52
[email protected]
Madrid C/ LUIS I, 88, 3ª planta 28031 - MADRID ESPAÑA
PUBLIC ADDRESS Tel: +34 91 311 60 76 Fax: +34 91 450 19 97
[email protected]
Systems Rev. 0
610.498A
1
2
EPD-240 FRONT PANEL
POWER PROT
POWER AMPLIFIER
CLIP
CLASS-D
ON OFF
INPUT OUTPUT
3
7
6
5
4
3
2
1
1
ON/OFF Switch button.
4
PROT. Light: It is activated either when detecting an overcharge, short circuit or open circuit on the output as well as an excess of the internal temperature.
2
POWER light.
5
CLIP Light: Indicates excessive modulation.
6
INPUT Light: Indicates when a valid signal is detected on the input.
3
Ventilation’s front grid. 7
OUTPUT Light: Indicates when a valid signal is detected on the output.
REAR PANEL
CAUTION
AVISO
RISK OF ELECTRIC SHOCK DO NOT OPEN RIESGO DE CHOQUE ELECTRICO NO ABRIR EN TENSION
S
CH1
VOLUME MASTER
OFF
Amplificador de Potencia Power Amplifier
13
CONFIG SELECTION
CH1 SPEAKER OUTPUT
110-230VAC 50/60Hz
14
12
LINE INPUT
EPD-240
24VDC IN
11
9
1
10
2
3
4
Selector for STANDBY and HIGH PASS FILTER
11 Line Input (balanced / unbalanced)
9
Ventilation’s front grid.
12 Master Volume
/ L100V.)
ON
20-20KHz
3-4 OFF 80-20KHz HIGH PASS FILTER
8
9
8
10 Speaker output (8
ON
STANDBY: ON Shut down 1-2 OFF Auto standby
13 Power Supply DC Input (24 VDC) 14 Main Power Supply Cable (110-230 VAC)
LINE SPEAKERS CONNECTION
STANDBY AND HIGH PASS FILTER CONFIGURATION
OFF
1 2 3 4
ON
STANDBY: 1-2 ON Shut down
COM
L100V
OFF Auto standby
8
COM
8 ohms
ON 20-20KHz 3-4 OFF 80-20KHz
HIGH PASS FILTER: STANDBY: ON Mode: The amplifier never enters Standby mode. It is always operative. OFF Mode: The amplifier enters Standby mode when it is switched on and exits once an input signal is detected. If during two minutes no signal is detected on the input, the amplifier enters Standby mode.
INPUTS CONNECTION
s
s
Unbalanced
Balanced s
HIGH PASS FILTER: ON Mode: Filter disabled. OFF Mode: Filter enabled.
Rev. 0
610.498A
2
2