EPS 7000 Three Phase UPS > High output power factor (0.9 pƒ) > Low kVAR input filter > No leading power factor > High energy efficiency > Reduced footprint > High power density > Fault tolerant architecture EPS 7000 EPS 7000 300kVA/270kW 400kVA/360kW 500kVA/450kW 300kVA/270kW 400kVA/360kW 500kVA/450kW Input/Output Voltage: 480/480V 480/480V 480/480V 600/600V 600/600V 600/600V Nominal Input Current: 371A 508A 656A 322A 441A 569A Maximum Input Current: 543A 688A 840A 466A 586A 711A Nominal Bypass Current: 361A 481A 601A 289A 385A 481A UPS Output Current: 361A 481A 601A 289A 385A 481A Input CB Trip/Frame Size: 1000/1200A 1000/1200A 1000/1200A 1000/1200A 1000/1200A 1000/1200A Maintenance Bypass Trip / Frame Size (A): 800/1200A 800/1200A 800/1200A 700/1200A 700/1200A 700/1200A DC Current (Max): 721 962 1195 721 962 1195 DC Breaker Trip/ Frame Size (A): 700/1200A 1000/1200A 1200/1200A 700/1200A 1000/1200A 1200/1200A System Efficiency: 94% 94% 93% 94% 94% 93% Full Load Heat Rejection (BTUs): 59400 78100 110750 65000 86000 112000 Input IGBT/PWM inverter, Low kVAR solid state input filter, K-20 output transformer, Redundant fans, Advanced battery management system, Detailed metering system, Fault current management circuitry, Two stage input current limit, Serial and dry contact interface, Local and remote E.P.O circuit, High capacity 100% rated static transfer switch DC Rating Nominal Voltage: 480Vdc Environmental Specifications Voltage: 480 or 600Vac, ±10%, 3 phase, 3 wire + ground Frequency: 60Hz + 5% Power Factor: 0.9 lagging with filter THDI: 7% THDI at full load Reactive Current (kVAR): <15% of nominal input current Inrush Current: up to 600% nominal current for less than one cycle Power Walk-in: 0 to 100% over a 10 second period Bypass Input Acoustical Noise Level: 75dBA at 5ft Operating Temperature: 0 to 40°C / 32 to 104°F Storage Temperature: -20 to 45°C / -4 to 113°F Humidity: 0 to 90% non-condensing Dimensions UPS Module (in/mm): 69 x 82 x 39 / 1752.6 x 2082.8 x 990.6 Voltage: 480 or 600Vac, ±3%, 3 Phase, 3 or 4 wire + ground Weight (lb/kg): 6900 / 3129.8 Power Factor: 0.9 at nominal kVA/up to unity at rated nominal kW Maintenance Bypass Cabinet (in/mm) (lb/kg): 22.75 x 82 x 39 / 557.9 x 2082.8 x 990.6 540 / 224.9 Frequency: 60Hz + 0.1% free running synchronized with bypass (selectable in 0.25Hz increments) Bottom Entry Cabinet (in/mm) (lb/kg): 14 x 82 x 39 / 355.6 x 2082.8 x 990.6 190 / 86.2 Voltage Regulation: ±0.5% steady state Voltage Recovery Time: ±1% of the steady state value within 1 cycle Transformer Cabinet (in/mm) (lb/kg): 44.75 x 82 x 39 / 1136.7 x 2082.8 x 990.6 3600 / 1632.9 Voltage Distortion: 2% L-L (4% L-N) THDI max Inverter Overload: 125% for 10min, 150% for 1min Unbalanced Load: Up to 100% 120° ±3% maximum angle displacement, ±3% maximum voltage deviation Options: input isolation transformer, output distribution, external maintenance bypass, bottom cable entry, remote alarm status panel, seismic anchors, battery monitoring, battery disconnect, SNMP/Network management card, critical bus synchronization module, graphical user interface with network connection, continuous duty and momentary duty static switch cabinets (SSC) Alpha Technologies Inc. Voltage: Must match rectifier input, ±10% UPS Output Voltage (3 phase, 3/4 wire + ground) Frequency: 60Hz (±0.25Hz up to 2Hz) Output www.alpha.com Three Phase UPS Standard Features 63