Transcript
Read this document carefully before using this device. The guarantee will be expired by damaging of the device if you don't attend to the directions in the user manual. Also we don't accept any compensations for personal injury, material damage or capital disadvantages.
ENDA EPDA1 / EPAA1 Panel Mountable Solid State Relays Thank you for choosing ENDA EPDA1 / EPAA1series Solid State Relays * 12-25-40-50-70-100-120A AC load current. * 280-480 AC load voltage. * 8-30V AC/DC or 90-240V AC input voltage. * LED status indicator for input voltage. * Zero-cross switching. * Applicable for three phase loads. * Built-in varistor protection. * Panel mountable. * CE marked according to European Norms .
ORDER CODE
2 AD A C LO-280VA
A 225Z ND 1 -
EEPDA
R SS
EP D A 1 - 2 25 Z
4
Product Basic Code Panel type SSR EP
Switching Zero crossing
Input voltage 8-30V AC/DC 90-240V AC
D A
Load voltage AC
A
Pole number Single-pole
Load current 12A AC 12 25A AC 25 40A AC 40 50A AC 50 70A AC 70 100A AC 100 120A AC 120
1 Load voltage 24-280V AC 50-480V AC
2x
25
24
1
4 :10 SN
Y LA RE
ON
xx
xx
3
T C PUC/D IN30V A 8-
Z
2 4
ENVIRONMENTAL CONDITIONS Ambient-storage temperature Relative humidity Pollution degree Overvoltage category Altitude Protection
-25... +60 °C / -30... +100 °C (In the environment icing and condensation should not be.) At +40° C %50, temperature was reduced at +20°C could be %90 . (Condensation should not be.) 2 II Max. 1000m IP20 According to EN60529
Do not use the device in locations subject to corrosive and flammable gases.
OUTPUT Order Code Load curent, AC51/25ºC (Arms) Load voltage (Vrms) Overload current t=1s/25°C (Arms) Non rep.surge current/25°C (Arms) On-state voltage drop (Vrms) Leakage current (mArms) I²t For fusing t=10ms (A²s) Frequency (Hz) Minimum operating current (mArms)
EPxA1-212Z EPxA1-225Z EPxA1-240Z EPxA1-425Z EPxA1-440Z EPxA1-450Z EPxA1-470Z EPxA1-4100Z EPxA1-4120Z 40 70 25 50 12 25 40 100 120 24 - 280 50 - 480 720 150 540 110 360 70 50 85 150 1350 1800 400 290 190 380 900 120 250 1,8 1,8 1,6 10 20 20 8 5 15 610 16200 9100 4000 78 340 880 265 720 50 - 60 50 - 60 50 - 60 500 160 300 500 200 400
THERMAL SPECIFICATIONS Tj Junction temperature (°C) Rth(j-c) Junction-case thermal resistance (°C/W) Rth(j-a) Junction-ambient thermal resistance (°C/W)
≤125 ≤1,2 ≤20
≤125 ≤0,7 ≤20
≤125 ≤1,2 ≤20
≤125 ≤1,0 ≤20
≤125 ≤0,6 ≤20
≤125 ≤0,4 ≤20
≤125 ≤0,3 ≤20
≤125 ≤0,25 ≤20
INPUT Order code Input voltage Pick-up voltage Drop-out voltage Input current Turn-on time Turn-off time LED indicator
EPDA1-xxxZ 8 - 30Vac/dc > 6Vac/dc < 2Vac/dc < 17mAac/10mAdc Maximum ½ Period Maximum ½ Period If the input voltage >6V ac/dc, LED lights up.
EPAA1-xxxZ 90 - 240Vac > 75Vac < 6Vac < 8mAac Maximum 1 Period Maximum 2 Period If the input voltage >75V ac, LED lights up.
GENERAL Order code Dimensions Weight Isolation voltage Connection Terminal screw torque
Product standard Mounting Enclosure material
EPxA1-xxxZ W45xH62xD31mm For EPxA1-2xx/4xxZ 95g , For EPxA1-550/570Z 110g , For EPxA1-5100/5120Z 115g (After packaging) 2500Vrms between I/O terminals for 1 min. For power line 16mm² (with cable terminal 25mm² ) cable, for signal line 4mm² cable can be connected. For power line max. 2,2Nm, for signal line max. 1,2Nm. EN 60947-4-3 With M4 screws is mounted to the panel. Self extinguishing plastics (. (According to EN 60695-11-10 V-O)
While cleaning the device, solvents (thinner, benzine, acid etc.) or corrosive materials must not be used.
1/2
EPxA1-xxxZ-E-02-R
CONNECTION DIAGRAM
DIMENSIONS 31 mm
51 mm
62 mm
RELAY ON
INPUT
3
8-30V AC/DC
3
4
2 x M3
2
SN:1042xxxxx
EPDA1-225Z SSR
LOAD
ENDA
24-280VAC 25A
SN:1042xxxxx
RELAY ON
2
INPUT
24-280VAC 25A
8-30V AC/DC
LOAD
1
1
4
EPDA1-225Z SSR
2 x M5
ENDA
11,6 5
3
2
VARISTOR
45 mm
ZERO CROSS CIRCUIT
INPUT AC/DC
OUTPUT AC
RELAY ON
4
1
high temperature
HEATSINKS ETS-46-62 HEATSINK
24V DC FAN
46 mm
40 mm
ETS-46-62 ETS-46-80 ETS-46-100 ETS-46-62 Fan ile ETS-46-80 Fan ile ETS-46-100 Fan ile
62 mm
39 mm
61mm
40 mm
Aluminium Heatsink
Dimensions Thermal (mm) Resistance (°C/W) 46x61x62 46x61x80 46x61x100 46x61x72 46x61x90 46x61x110
2,4 2,0 1,6 1,7 1,4 1,0
Supply : 24V DC Current: 100mA 10
The fan must be mounted to it so that the low part of the cooler.
Airflow must be to the cooler.
CONNECTION EXAMPLES Single Phase Load Application
Three Phase Load Application With The Two SSRs
R N
R S T
R S T N
Load 4 RELAY ON
LOAD
24-280VAC 25A
INPUT
8-30V AC/DC
Fuse
3
2 4 RELAY ON
LOAD
24-280VAC 25A
INPUT
2
3
SN:1042xxxxx
RELAY ON
LOAD
24-280VAC 25A
INPUT
8-30V AC/DC
Fuse
8-30V AC/DC
4
INPUT
1
EPDA1-225Z SSR
ENDA
INPUT
1
EPDA1-225Z SSR
ENDA
SN:1042xxxxx
2
3
SN:1042xxxxx
INPUT
Fuse
1
EPDA1-225Z SSR
RELAY ON
LOAD
24-280VAC 25A
INPUT
8-30V AC/DC
ENDA
4
1
EPDA1-225Z SSR
ENDA
INPUT
Three Phase Load Application With Three SSRs
Fuse
2
3
4 RELAY ON
LOAD
24-280VAC 25A
INPUT
8-30V AC/DC
2
3
SN:1042xxxxx
Fuse
4
1
RELAY ON
LOAD
INPUT
8-30V AC/DC
24-280VAC 25A
EPDA1-225Z SSR
ENDA
INPUT
1
EPDA1-225Z SSR
ENDA
SN:1042xxxxx
INPUT
2
3
SN:1042xxxxx
Fuse
SÝSEL MÜHENDÝSLÝK ELEKTRONÝK SAN. VE TÝC. A.Þ. Yukarý Dudullu Barbaros Cad. Kutup Sok. No:20 34775 - ÜMRANÝYE/ÝSTANBUL/TÜRKÝYE Tel : +90 216 499 46 64 Pbx. Fax : +90 216 365 74 01 url : www.enda.com.tr 2/2
EPxA1-xxxZ-E-02-R