Transcript
User’s Manual and Operating Instructions Model Numbers: PT-18W-DDF-A, PT-20F-DDF-A, PT-20S-DDF, PT-24O-DDF, PT-24-DDF, PT-24-DDF-F, PT-30-DDF, PT-30P-DDF-A, PT-30P-DDF-AF
READ AND SAVE THESE INSTRUCTIONS IMPORTANT: Read and understand all of the instructions in this manual before assembling, starting, or servicing the fan. Improper use of this fan can cause serious injury. Keep this manual for future reference. For General Ventilating Use Only. Do Not Use To Exhaust Hazardous Or Explosive Materials And Vapors. Never use the fan in spaces which contain products such as gasoline, solvents, paint thinners, dust particles, volatile or airborne combustibles, or any unknown chemicals. CAUTION
This product meets and exceeds the requirements of OSHA 1910.212(a)(5), the standard which regulates electric fan blade safety, and is certified under UL# E355088. Please note the serial number of your fan, and write it on the back of this User’s Manual for future reference.
© 2013, Pinnacle Products International, Inc. 668 Stony Hill Road #302 Yardley, PA 19067 USA Toll Free: (800) 641-6996 Fax: (215) 891-8461 • Web: www.protemp.us • Email:
[email protected] 9500450290-13
User’s Manual and Operating Instructions Table of Contents
Safety Information................................................................................................................................. 3 Notes Page............................................................................................................................................4 Troubleshooting Guide........................................................................................................................19 Warranty................................................................................................................................Back Cover
5
18” Wall Fan PT-18W-DDF-A
6-7
20” Floor Fan PT-20F-DDF-A
8-10
20” Shop Fan PT-20S-DDF
11
24” Barrel Fan PT-24-DDF PT-24-DDF-F
17-18
30” Pedestal Fan
PT-30P-DDF-A PT-30P-DDF-AF
12-13
24” Omni Fan PT-24O-DDF
14-16
30” Floor Fan PT-30-DDF
© 2013, Pinnacle Products International, Inc.
2
HVF Air Circulator User’s Manual
NEVER LEAVE A FAN UNATTENDED WHILE OPERATING OR WHILE CONNECTED TO A POWER SOURCE
Safety Information IMPORTANT: READ ALL INSTRUCTIONS CAREFULLY BEFORE ASSEMBLY, SERVICE OR USE OF THIS FAN. FAILURE TO COMPLY WITH THESE INSTRUCTIONS COULD RESULT IN SERIOUS PERSONAL INJURY AND / OR PROPERTY DAMAGE. THIS IS A FAN - NOT A TOY! WARNING TO REDUCE THE RISK OF PERSONAL INJURY AND ELECTRIC SHOCK, FANS SHOULD NOT BE PLAYED WITH OR PLACED WHERE SMALL CHILDREN CAN REACH IT.
Installation work and electrical WARNING wiring must be done by qualified person (s) in accordance with all applicable codes and regulations. When servicing or replacing a WARNING component requires the removal or disconnection of a safety device, the safety device is to be reinstalled or remounted as previously installed before operating this fan.
To guard against electric shock WARNING while operating, do not allow fan to come in contact with other grounded objects such as pipes, radiators, etc.
Use this fan only in the manner WARNING intended by the manufacturer. If you have any questions, contact Customer Service at 800-641-6996.
Risk of fire, electric shock, or WARNING personal injury when performing service or maintenance. Unplug or disconnect the fan from the power supply before servicing.
- Before operating always check fan for loose or damaged parts. Inspect power cord for any damage. Never use fan if any parts are damaged or missing. Never use fan without safety guards attached. - Operate only on 120 volt 60 Hz (cycle) current with a minimum of a 15 amp circuit.
CAUTION Automatically WARNING Operated Device - To Reduce The Risk Of Injury Disconnect From Power Source Before Servicing To Reduce The Risk Of Fire WARNING Or Electric Shock, Do Not Use This Fan With Any Solid- State Speed Control Device.
- When used with an extension cord, use only cord of proper size (Amp rating), UL listed, and with receptacle to accept three prong grounded plug furnished on the fan’s power cord. Always keep power cord and extension cords away from heat, oil, and sharp edges. Inspect cords periodically and replace if damaged.
To Reduce The Risk Of Electric WARNING Shock And Injury To Persons, Do Not Use In a Window. To Reduce The Risk Of Electric WARNING Shock, Do Not Expose To Water Or Rain. This unit is designed for indoor use only.
© 2013, Pinnacle Products International, Inc.
3
HVF Air Circulator User’s Manual
NEVER LEAVE A FAN UNATTENDED WHILE OPERATING OR WHILE CONNECTED TO A POWER SOURCE
NOTES __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ © 2013, Pinnacle Products International, Inc.
4
HVF Air Circulator User’s Manual
NEVER LEAVE A FAN UNATTENDED WHILE OPERATING OR WHILE CONNECTED TO A POWER SOURCE
Wall Mount Installation
18” WALL FAN: PT-18W-DDF-A WARNING The installer MUST be certain that the support bracket is mounted to a minimum of a 2x4” stud, and that it is able to support 50 pounds continuously.
1. Attach fan to wall or ceiling using Upper Bracket (Item #6). 2. Be sure Upper Bracket (Item #6) is attached to a suitable beam when hanging. Tools Needed: - 10mm Adjustable Wrench.
Exploded View 1
2
3
4
6
5
7
8
9
10 11
12
17 16 15
14
18
13
Figure 1: Exploded View of PT-18W-DDF-A
Replacement Parts Item # 1 2 3 4 5 6 7 8 9
Description
Part Number
Item #
Logo Plate Front Guard
95-043-0370 95-032-0150
Fan Blade Assembly
95-003-0606
Upper Bracket Rear Guard Motor Switch Holder
95-061-0100 95-032-0250 95-030-0515 95-031-0300
10 11 12 13 14 15 16 17 18
© 2013, Pinnacle Products International, Inc.
5
Description
Part Number
Switch Gasket Switch (Chain) Switch Cover Cord Bushing Pivot Washer Swivel Spacer Pivot Screw Capacitor Power Cord
95-031-0340 95-031-0110 95-031-0500 95-026-0160 95-024-0300 95-050-0185 95-024-0310 95-004-0215 95-026-0230
HVF Air Circulator User’s Manual
NEVER LEAVE A FAN UNATTENDED WHILE OPERATING OR WHILE CONNECTED TO A POWER SOURCE
20” FLOOR FAN: PT-20F-DDF-A Installation and Assembly 1. Remove 1 screw from each Frame Support L and R (Items #7* and #19*).
4. Place the fan on level ground in a safe, desired position then connect to an approved power source.
2. Slide Frame Support L and Frame Support R into Support Frame (Item #21*) and line up holes for screw.
Tools Needed: - Phillips head screwdriver. -10 mm adjustable wrench.
3. Re-attach screw to Frame Support L and Frame Support R.
20” FLOOR FAN - OPTIONAL WALL MOUNT Wall Mount Installation 1. Attach wall mount to stud (Item #24*)
The installer MUST be WARNING certain that the support bracket is mounted to a minimum of a 2x4” stud, and that it is able to support 50 pounds continuously.
2. Attach Lower Support Frame (Item #21*) to the Wall Mount (Item #24*) by replacing rear part of Lower Support Frame into hook of Wall Mount and resting front and rear feet of fan (Items #17* and #18*) onto the wall.
NOTE: Fan must be mounted to wall so that both feet are positioned against the wall surface. Mounting this fan to a bare stud without both fan feet positioned against a flat surface will result in damage to the fan.
* On Page 7
Figure 3: Wall Mount Installation - Close Up
Figure 2: Wall Mount Installation
© 2013, Pinnacle Products International, Inc.
6
HVF Air Circulator User’s Manual
NEVER LEAVE A FAN UNATTENDED WHILE OPERATING OR WHILE CONNECTED TO A POWER SOURCE
20” FLOOR FAN CONTINUED Exploded View 1
2
3
4
5 6 7 8
10
9
11
14 15 16 12 13
24
21
19 18
20
23
22
17
Figure 4: Exploded View of PT-20F-DDF-A
Replacement Parts Item # 1 2 3 4 5 6 7 8 9 10 11 12
Description
Part Number
Item #
Description
Part Number
Logo Plate Front Guard
95-043-0405 95-032-0160
Fan Blade Assembly
95-003-0616
Frame Washer Frame-Support L Main Circle Tube Top Washer Rear Guard Motor Switch Holder
95-024-0250 95-024-0265 95-024-0280 95-024-0290 95-032-0260 95-030-0525 95-031-0310
13 14 15 16 17 18 19 20 21 22 23 24
Switch Switch Cover Cord Bushing Control Knob Front Foot Rear Foot Frame-Support R Swivel Spacer Lower Support Frame Power Cord Capacitor Wall Mount Kit
95-031-0120 95-031-0510 95-026-0165 95-027-0110 95-023-0220 95-023-0230 95-024-0275 95-050-0180 95-024-0245 95-026-0240 95-004-0225 95-078-0100
© 2013, Pinnacle Products International, Inc.
7
HVF Air Circulator User’s Manual
NEVER LEAVE A FAN UNATTENDED WHILE OPERATING OR WHILE CONNECTED TO A POWER SOURCE
20” SHOP FAN: PT-20S-DDF Installation and Assembly 1. Remove Knob Screw (Item #15*) and Wing Nut (Item #14*) from top of Post.
5. Place the fan on level ground in a safe, desired position then connect to an approved power source.
2. Slide Connector Bracket (Item #4*) onto top of post.
6. Set desired tripod stand height following “Tripod Operation Instructions” below.
3. Line up holes on the Post and Connector Bracket (Item #4*). 4. Re-insert the Knob Screw (Item #15) through the Post and Connector Bracket (Item #14*) and tighten firmly with the Wing Nut (Item #14*).
* On Page 10
Tripod Operation Instructions Tripod Leg Operation
TRIPOD CENTER POST OPERATION
1. Fold legs out and slide support bracket to center of leg.
1. To change the post height; rotate locking ring counter-clockwise to unlock post.
2. To adjust leg height; rotate locking ring clockwise to loosen.
NOTE: Be certain to keep a firm grip on post while unlocked! The fan will slide down to its lowest point if it is not held and slowly moved to desired position.
NOTE: Keep a firm grip on the tripod while leg is unlocked! The leg will collapse into itself unless held tightly.
2. Raise or lower post to desired position.
NOTE: Be certain to make all three legs the same height. Setting legs to different heights will make the fan unbalanced and COULD FALL OVER.
3. Rotate locking ring clockwise to lock post and tighten firmly.
3. Slide leg extension to desired height.
WARNING DO NOT MOVE OR ADJUST FAN WHILE IN OPERATION. THIS CAN CAUSE DAMAGE TO FAN AND INJURY TO THE OPERATOR.
4. Rotate locking ring counter-clockwise and tighten firmly. Be sure the leg is secure before moving to next leg. 5. Repeat steps 2-4 for remaining legs.
OPTIONAL CEILING MOUNT Installation and Assembly 2. Slide Connector Bracket (Item #4*) onto Ceiling Mounting Post. (See Figure 7**)
1. Attach Ceiling Mounting Kit (Item #16*) to 2x4” stud that is able to support 50 lbs continuously using M6x40mm screw. (See Figure 5**)
4. Rotate the entire fan so the safety pin locks into place and the holes on the Mounting Post line up with the holes on the Connector Bracket (Item #4*). (See Figure 8**)
The installer MUST be WARNING certain that the support bracket is mounted to a minimum of a 2x4” stud, and that it is able to support 50 pounds continuously.
5. Insert the Knob Screw (Item #15*) through the Mounting Post and Connector Bracket (Item #4*) and tighten firmly with the Wing Nut (Item #14*). (See Figure 8**)
3. Be Certain that the Safety Pin lines up with the groove on the Connector Bracket (Item #4). (See Figure 6**)
© 2013, Pinnacle Products International, Inc.
* On Page 10 ** On Page 9
8
HVF Air Circulator User’s Manual
NEVER LEAVE A FAN UNATTENDED WHILE OPERATING OR WHILE CONNECTED TO A POWER SOURCE
20” SHOP FAN CONTINUED - OPTIONAL CEILING MOUNT
Figure 5: Optional Ceiling Mount
Figure 6: Optional Ceiling Mount
Figure 7: Optional Ceiling Mount
Figure 8: Optional Ceiling Mount
© 2013, Pinnacle Products International, Inc.
9
HVF Air Circulator User’s Manual
NEVER LEAVE A FAN UNATTENDED WHILE OPERATING OR WHILE CONNECTED TO A POWER SOURCE
20” SHOP FAN CONTINUED Exploded View
1
2 3
4
5
14
6
7
15
8
9
10 11
13
12
16
Figure 9: Exploded View of PT-20S-DDF
Replacement Parts Item # Description 1 Logo Plate 2 Front Guard 3 Fan Blade Assembly 4 Frame 5 Rear Guard 6 Motor 7 Switch Holder 8 Power Cord
Part Number 95-043-0420 95-032-0185 95-003-0616 95-001-0500 95-032-0285 95-030-0525 95-031-0335 95-026-0270
© 2013, Pinnacle Products International, Inc.
Item # 9 10 11 12 13 14 15 16
10
Description Power Switch Capacitor Bushing Switch Cover Tripod Wing Nut Base Knob Ceiling Mount Kit
Part Number 95-025-0600 95-004-0250 95-026-0180 95-031-0540 95-040-0100 95-075-0400 95-015-0220 95-078-0300
HVF Air Circulator User’s Manual
NEVER LEAVE A FAN UNATTENDED WHILE OPERATING OR WHILE CONNECTED TO A POWER SOURCE
24” BARREL FAN: PT-24-DDF, PT-24-DDF-F Installation and Assembly 1. Fully expand Pipe Frame (Item #20) open, and tighten Frame Brackets (Items #21 and #22) with attached bolt.
Exploded View
2. Place the fan on level ground in a safe, desired position then connect to an approved power source.
NOTE: This model CAN NOT be wall mounted.
Figure 10: Exploded View of PT-24-DDF / PT-24-DDF-F
Replacement Parts Item # 1 2 3 4 5 6 7 8 9 10 11 12
Description Logo Plate Front Guard
Part Number 95-043-0410 95-032-0170
Fan Blade Assembly
95-003-0621
Rubber Washer A Rubber Washer B Barrel Handle Rear Guard Motor Switch Holder
95-077-0100 95-077-0110 95-001-0300 95-006-0210 95-032-0270 95-030-0530 95-031-0320
© 2013, Pinnacle Products International, Inc.
Item # 13 14 15 16 17 18 19 20 21 22 23 24 11
Description Switch Cord Bushing Switch Cover Control Knob Power Cord Capacitor Foot Pipe Frame L/R Frame Bracket A Frame Bracket B Wheel Bolt Wheel
Part Number 95-031-0130 95-026-0170 95-031-0520 95-027-0120 95-026-0250 95-004-0230 95-023-0210 95-009-0500 95-009-0510 95-009-0520 95-008-0310 95-008-0110
HVF Air Circulator User’s Manual
NEVER LEAVE A FAN UNATTENDED WHILE OPERATING OR WHILE CONNECTED TO A POWER SOURCE
24’’ OMNI DIRECTIONAL FAN: PT-24O-DDF Installation and Assembly 1. Place the fan on level ground in a safe, desired position then connect to an approved power source.
Exploded View 3 1
2
4 5
10
8 6 7
15 16
11 12
13
17
14
9 18
19
20
31
29
30
27
Replacement Parts 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Description
Front Guard Fan Barrel Power Knob Power Knob Holder Capacitor Power Cord Motor Motor Mount Assembly Motor Cooling Fan Fan Blade Assembly Rear Guard Front Leg Horizontal Adj. Knob Spacer Outer Ring Frame
Item #
Part Number
16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31
95-032-0170 95-001-0400 95-027-0130 95-031-0325 95-004-0235 95-026-0255 95-030-0535 95-030-0555 95-030-0556 95-003-0621 95-032-0275 95-009-0600 95-015-0150 95-050-0200 95-024-0320
© 2013, Pinnacle Products International, Inc.
12
21
23 26
Figure 11: Exploded View of: PT-24O-DDF
Item #
22
28
Description
Vertical Adj. Knob Wall Mount Handle Pad Spacer Handle Arm Rear Leg Large Base Cap Large Base Foot Pad Wall Bracket - L Wall Bracket - R Small Base Small Base Cap Wheel Lower Mount Logo Plate
25
24
Part Number 95-015-0150 95-078-0200 95-007-0100 95-050-0200 95-006-0300 95-009-0610 95-024-0410 95-024-0400 95-023-0240 95-077-0100 95-077-0110 95-024-0500 95-024-0510 95-004-0155 95-024-0325 95-043-0331
HVF Air Circulator User’s Manual
NEVER LEAVE A FAN UNATTENDED WHILE OPERATING OR WHILE CONNECTED TO A POWER SOURCE
24” OMNI FAN - OPTIONAL WALL MOUNT Wall Mount Installation WARNING The installer MUST be 1. Attach Wall Mount (Item #17*) to wood stud as shown below. 2. Slide Wall Bracket L (Item #25*) and Wall Bracket R (Item #26*) on Large Base (Item #23*) onto Wall Mount.
certain that the support bracket is mounted to a minimum of a 2x4” stud, and that it is able to support 105 pounds continuously.
Tools Needed -Flat head Screw Driver.
* On Page 12
2”x4” STUD
Wall Mount (Item #17*)
Figure 12: Wall Mount installation Close Up
Handle Arm (Item #20*) Wall
Large Base (Item #23*) Wall Mount (Item #17*)
Figure 13: Wall Mount installation
© 2013, Pinnacle Products International, Inc.
13
HVF Air Circulator User’s Manual
NEVER LEAVE A FAN UNATTENDED WHILE OPERATING OR WHILE CONNECTED TO A POWER SOURCE
30” FLOOR FAN: PT-30-DDF Installation and Assembly
NOTE: This fan uses a folding wheel design. For quick assembly, simply swing the wheels out and snap to lock in place.
1. Place the fan on level ground in a safe, desired position then connect to an approved power source.
Exploded View
7 8 9
10 15
11
25 16
17
19
18
21
22
23
20
1
4
2 25
6
5
3 12
24
13
14
Figure 14: Exploded View of PT-30-DDF
Replacement Parts Item# Description 1 Front Guard 2 Front Swivel Bracket 3 Fan Blade Assy 4 Motor 5 Frame Foot 6 Cart Frame 7 Swivel Cover 8 Frame Swivel Bracket 9 Frame Upper Swivel Latch 10 Swivel Latch Pin 11 Frame Cap 12 Wheel
Part Number 95-032-0140 95-050-0100 95-003-0501 95-030-0500 95-023-0200 95-009-0400 95-050-0106 95-050-0111 95-050-0120 95-050-0131 95-011-0300 95-008-0165
© 2013, Pinnacle Products International, Inc.
Item# Description 13 Wheel Axle 14 Wheel Frame 15 Upper Swivel Housing 16 Frame Lower Swivel Latch 17 Latch Spring 18 Lower Swivel Housing 19 Rear Guard 20 Rear Swivel Bracket 21 Capacitor 22 Power Switch 23 Rear Motor Cover 24 Power Cord 25 Guard Screw 14
Part Number 95-008-0260 95-008-0500 95-050-0141 95-050-0150 95-060-0155 95-050-0161 95-032-0240 95-050-0170 95-004-0200 95-025-0500 95-048-0100 95-026-0150 95-033-0225
HVF Air Circulator User’s Manual
NEVER LEAVE A FAN UNATTENDED WHILE OPERATING OR WHILE CONNECTED TO A POWER SOURCE
30” FLOOR FAN - OPTIONAL CEILING MOUNT Ceiling Mount Installation WARNING The installer MUST be MOUNTING BRACKET INSTALLATION: 1. Remove Wheel Frame (Item #15) 2. Attach Cart Frame to Ceiling beam using U-bolts (Item #5). 3. Assemble and attach Ceiling Mount Assembly as shown in Figure 15 below.
certain that the support bracket is mounted to a minimum of a 2x4” stud, and that it is able to support 105 pounds continuously. This 30” Floor Fan (PT-30-DDF) is approved for use with California’s BAR-97 Emissions Inspection System and meets all BAR-97(EIS) required specifications and standards
Tools Needed - Phillips and flat head screw driver. - 10 mm adjustable wrench.
Ceiling Kit Exploded View 3
2 4 1
5 6 7 8 9
Figure 15: Exploded View of PT-30-DDF (ceiling mount kit)
Ceiling Kit Replacement Parts Item# Description 1 Safety Cable Assy 2 Nut for Ceiling Swivel Pin 3 Nut 4 Upper Ceiling Bracket 5 U-Bolt
Part Number 95-060-0100 95-060-0180 95-060-0125 95-060-0110 95-060-0120
© 2013, Pinnacle Products International, Inc.
Item# Description 6 Top Washer 7 Lower Ceiling Bracket 8 Tapping Screw 5-15mm 9 Ceiling Swivel Pin 15
Part Number 95-060-0120 95-060-0160 95-060-0195 95-060-0170
HVF Air Circulator User’s Manual
NEVER LEAVE A FAN UNATTENDED WHILE OPERATING OR WHILE CONNECTED TO A POWER SOURCE
30” FLOOR FAN - OPTIONAL CEILING MOUNT CONTINUED Ceiling Mount Installation 1. 2. 3. 4. 5.
SAFETY CABLE INSTALLATION: After the fan is securely mounted, feed the safety cable between one of the swivel brackets as shown in Figure 15. Pull safety cable through and secure cable with safety cable U-bolt as shown in Figure 17. Take other end of cable and wrap around beam Secure cable loop as shown in step 2. Be sure there is approximately 2 inches of slack in the safety cable once both ends are secured. Repeat on other side of fan so there are two safety cables.
Tools Needed - Phillips and flat head screw driver. - 10 mm adjustable wrench
WARNING The installer MUST be certain that the support bracket is mounted to a minimum of a 2x4” stud, and that it is able to support 105 pounds continuously.
Figure 16: Safety Cable Installation
© 2013, Pinnacle Products International, Inc.
Figure 17: Safety Cable Installation - Close Up
16
HVF Air Circulator User’s Manual
NEVER LEAVE A FAN UNATTENDED WHILE OPERATING OR WHILE CONNECTED TO A POWER SOURCE
30” PEDESTAL FAN: PT-30P-DDF-A, PT-30P-DDF-AF 1. Attach Rubber Base Ring (Item #16*) to outer edge of Installation and Assembly
Base (Item # 5*). Be sure ribbed side of Base Ring is facing down.
Tools Needed: Pliers Phillips head screwdriver Flat head screwdriver 10mm / adjustable wrench 6mm hex wrench (included)
2. Remove 5 screws from Flange on bottom of Lower Support Pole (Item #13*). 3. Completely extend Upper Support Pole (Item #21*) from Lower Support Pole and insert Spring into bottom of Lower Support Pole.
Parts Included In Box: (1) Rubber Base Ring (1) Base (1) Front Guard (1) Rear Guard (1) Motor Assembly (1) Fan Blade Assembly (1) Spring (1) Support Pole Assembly
4. Attach Support Pole Assembly to Base. Tighten hardware using star pattern to insure a tight, uniform fit. 5. Stand assembly on Base, and press down Upper Support Pole and then tighten Height Adjustment Knob (Item #3*). 6. Attach Motor Support Assembly to Motor Assembly (see Figure 18). Motor Assembly
Tilt Adjustment Knob
- Insert Pivot Bolt and tighten. - Insert Tilt Adjustment Knob and tighten.
8. Remove 4 screws on motor, and attach the Rear Guard. Tighten screws only after all 4 screws are reattached to the motor.
Machine Screw
Pivot Bolt
7. Place Motor Support into Upper Support Pole.
Motor Support Assembly Wing Nut
9. Remove the screws on the Motor and attach the Rear Guard onto groove in motor shaft, and replace screws (See Figure 19). 10. Loosen the set screw on the back of the Fan Blade Assembly and slide onto the motor shaft. 11. Position set screw over flat groove on motor shaft an tighten set screw using 6mm hex wrench (included). Be
NOT slide fan blade screw CAUTION Do beyond the groove on the shaft!
Nut Upper Support Pole
This will cause the fan blade to not spin properly and can cause damage to your fan! Be sure that fan shaft is flush with front of fan blade assembly. sure set screw is on the groove, and the front of Fan Blade Assembly is flush with front of shaft before tightening.
Figure 18: Attaching Motor to Motor Support Assembly
Rear Guard
Motor
12. Attach Front Guard by first aligning the top hooks of the Front Guard onto the top of the Rear Guard edge. Work your way around the Guard, placing the Front Guard hooks over the Rear Guard edge. If necessary, use a flat head screwdriver to help pry the Front Guard hooks over the Rear Guard edge. Continue until all hooks are completely attached to the Rear Guard edge. NOTE: This model CAN NOT be wall mounted * On Page 18
Figure 19: Attaching Rear Guard to Motor
© 2013, Pinnacle Products International, Inc.
17
HVF Air Circulator User’s Manual
NEVER LEAVE A FAN UNATTENDED WHILE OPERATING OR WHILE CONNECTED TO A POWER SOURCE
30” PEDESTAL FAN Exploded View 5
4
9
6
8 23
2
7
1
22
11
3
10
13
17
12
19
14 15 Figure 20: Exploded View of PT-30P-DDF-A / PT-30P-DDF-AF
18 16
20 21
Replacement Parts Item # 1 2 3 4 5 6 7 8 9 10 11 12
Description Part Number Logo Plate 95-043-0340 Front Guard 95-032-0181 Height Adjustment Knob 95-015-0205 Fan Blade Assembly
95-003-0631
Power Switch (Chain) Motor Assembly Rear Guard Height Adjust. Knob Nut Pipe Ring Pipe Support
95-031-0140 95-030-0545 95-032-0281 95-015-0215 95-017-0215 95-017-0220
© 2013, Pinnacle Products International, Inc.
Item # Description 13 Lower Support Pole 14 Latch Spring 15 Upper Base Lower Base (Rubber 16 Base Ring) 17 Motor Support 18 Left Support 19 Right Support 20 Tilt Adjustment Knob 21 Upper Support Pole 22 Power Cord 23 Capacitor 18
Part Number 95-017-0205 95-060-0210 95-024-0225 95-024-0235 95-030-0560 95-030-0570 95-030-0575 95-015-0210 95-010-0305 95-026-0260 95-004-0240
HVF Air Circulator User’s Manual
NEVER LEAVE A FAN UNATTENDED WHILE OPERATING OR WHILE CONNECTED TO A POWER SOURCE
Troubleshooting Guide Problem Fan does not operate
Reduced Air Flow Humming sound but no operation
Possible Cause
Corrective Action
1. No power
Inspect power cord for damage. Be sure unit is plugged in and turned on.
2. Bad motor
Replace motor
1. Obstruction
Turn off and unplug fan. Remove guard and make sure nothing is obstructing the fan blades.
2. Bad switch or capacitor
Replace switch or capacitor (Note: To prolong life of fan, operate fan first in 1(LOW) for 5-10 seconds before switching to higher speed.
1. Bad capacitor
Replace capacitor
Excess Noise (vibration, 1. Fan is not on level ground squealing) 2. Guard is not secure
© 2013, Pinnacle Products International, Inc.
19
Turn off fan, and move unit to smooth level surface. Check guard screws to be sure all are tight.
HVF Air Circulator User’s Manual
NEVER LEAVE A FAN UNATTENDED WHILE OPERATING OR WHILE CONNECTED TO A POWER SOURCE 1 YEAR LIMITED WARRANTY Pinnacle Products International, Inc. warrants this product to the original retail purchaser only, to be free from defects in material and workmanship for a period of one (1) year from the date of initial purchase. This product must be properly installed, maintained and operated in accordance with the instructions provided. Pinnacle Products International, Inc. requires reasonable proof of your date of purchase from an authorized retailer or distributor. Therefore, you should keep your sales slip, invoice, or cancelled check from the original purchase. This Limited Warranty shall be limited to the repair or replacement of parts, which prove defective under normal use and service within the warranty period, and which Pinnacle Products International, Inc. shall determine at its reasonable discretion. This warranty does not apply to products purchased for rental use. This Limited Warranty does not cover replacement of belts or tightening of belts, or any failures or operating difficulties due to normal wear and tear, accident, abuse, misuse, alteration, misapplication, improper installation or improper maintenance and service by you or any third party. Failure to perform normal and routine maintenance on the fan, shipping damage, damage related to insects, birds, or animals of any kind, and damage due to weather conditions are also not covered. In addition, the Limited Warranty does not cover damage to the finish, such as scratches, dents, discoloration, rust or other weather damage, after purchase. All transportation costs for the return of the damaged product or parts will be the responsibility of the purchaser. Upon receipt of damaged item, Pinnacle Products International, Inc. will examine the item and determine if defective.
Pinnacle Products International, Inc. will repair or replace and return the item, freight pre-paid. If Pinnacle Products International, Inc. finds the item to be in normal operating condition, or not defective, the item will be returned freight collect. This Limited Warranty is in lieu of all other express warranties. Pinnacle Products International, Inc. disclaims all warranties for products that are purchased from sellers other than authorized retailers or distributors. AFTER THE PERIOD OF THE ONE (1) YEAR LIMITED WARRANTY EXPIRES, Pinnacle Products International, Inc. DISCLAIMS ANY AND ALL IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR APPLICATION. FURTHER, Pinnacle Products International, Inc. SHALL HAVE NO LIABILITY WHATSOEVER TO PURCHASER OR ANY THIRD PARTY FOR ANY SPECIAL, INDIRECT, PUNITIVE, INCIDENTAL, OR CONSEQUENTIAL DAMAGES. Pinnacle Products International, Inc. assumes no responsibility for any defects caused by third parties. This Limited Warranty gives the purchaser specific legal rights; a purchaser may have other rights depending upon where he or she lives. Some states do not allow the exclusion or limitation of special, incidental or consequential damages, or limitations on how long a warranty lasts, so the above exclusion and limitations may not apply to you. Pinnacle Products International, Inc. does not authorize any person or company to assume for it any other obligation or liability in connection with the sale, installation, use, removal, return, or replacement of its equipment, and no such representations are binding on Pinnacle Products International, Inc.
Register Online at: www.protemp.us/Product_Registration.php Always be sure to specify model number and serial number when making any claim with Pinnacle Products International, Inc. For your convenience use the space provided below to list this information:
Model #: ____________________ Date of Purchase: _________________
Serial #: ______________________
© Pinnacle Products International, Inc. 668 Stony Hill Road #302 Yardley, PA 19067 USA Toll Free: (800) 641-6996 Fax: (215) 891-8461 • Web: www.protemp.us • Email:
[email protected]