Preview only show first 10 pages with watermark. For full document please download

Esight-nms

   EMBED


Share

Transcript

Security Level: 2012/2/21 eSight V2R2C00 Enterprise Router & Switch Marketing www.huawei.com HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Contents 1 Challenges for Enterprise Management Systems 2 Huawei eSight O&M Solution for Enterprises 3 Configuration Introduction HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 2 Network Status and Challenges Server HUAWEI  HP Multi-Vendors IP IT Multi-Resource Multi-NMS Unified Management Platform   Printer CISCO Devices Fax machine How to manage too many devices from different vendors in a unified manner? How to decrease operation and maintenance costs and improve maintenance Efficiency efficiency for enterprises? HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 3 Network Status and Challenges Management scope of IT departments:  Devices  Network stability  Network services  Network quality HUAWEI TECHNOLOGIES CO., LTD. Smart Management Huawei Confidential Page 4 Contents 1 Challenges for Enterprise Management Systems 2 Huawei eSight O&M Solution for Enterprises Overview Basic Network Management SLA Management MPLS Network Management WLAN Network Management 3 Configuration Introduction HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 5 eSight O&M Solution for Enterprises Any Customer   Multiple editions suit different enterprise requirements.  The he open secondary development platform and APIs satisfy Any Customer enterprises' requirements for integrating and developing personalized tools. Visible management High efficiency Any Device   Management of IP and IT devices from multiple vendors in a unified manner, reducing expenses. eSight Any Service Low expenses  Any Device Batch deployment, improving O&M efficiency. Any Service   Service Service-oriented SLA management, implementing visual demonstration of service quality.  WLAN visual management, wizard-based service configuration.  Unified monitoring of MPLS VPN networks, one-click fault diagnosis. HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 6 Lightweight System Running on portable computers Performance Fault Configuration Security Minimum hardware configuration: CPU: dual-core 2.0 GHz Memory: 2 GB Hard disk: 20 GB Report eSight Suitable for any place Web 2.0 B/S Browsers: Internet Explorer, Firefox, and so on  HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 7 Multi-Editions Editions for Any Customer Edition Express Compact Standard (Recommended) Scale 0-40 0-60 Unlimited Target Market  Features Resource management Topology management Alarm management Topology management NE management Alarm management Performance management Configuration file management Data dumping and backup. All functions of the compact edition  SOHO (free)  Only simply monitoring  SOHO or SMB network  Only device management  Medium- and large-sized sized network  Service management   Report management  Smart configuration tool  User-defined device management  Enterprise service management (WLAN, MPLS, SLA, and IPSec) Professional Unlimited  Super-large network  Hierarchical network management HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential  Northbound function  All functions of the standard edition  Hierarchical network management  Secondary development Page 8 Contents 1 Challenges for Enterprise Management Systems 2 Huawei eSight O&M Solution for Enterprises Overview Basic Network Management SLA Management MPLS Network Management WLAN Network Management 3 Configuration Introduction HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 9 Unified Device Management IP: Router, switch, WLAN device, security device, third third-party device Reduce OPEX IT: Server, workstation, printer, fax machine Manage third-party SNMP devices and support standard MIBs (RFC1213-MIB, EntityMIB, IF-MIB, and SNMPv2-MIB) HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 10 User-Defined Defined Device Management Customize basic NE information Customize NE management capabilities Simple, quick, and trouble-free Users can customize device information to manage devices of new types and third-party party devices that are not pre-adapted. pre HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 11 Device Adaption Package What should I do if devices do not support standard MIBs or there are devices of new types or versions? Download new device adaption package Install or upgrade device package eSight does not need to be upgraded. You simply need to install or upgrade the device adaption package to manage devices of new types or versions. Manage devices of new types or versions HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 12 One-Stop Stop Device Management Portal One-stop stop device information monitoring: HUAWEI TECHNOLOGIES CO., LTD.  Basic information  Device availability statistics  Top N alarms  Device performance  User-defined defined device information Huawei Confidential Page 13 Multiple Resource Discovery Modes 1: Specified IP address 192.168.0.2 2: IP address segment 192.168.0.1 to 192.168.0.100 3: CSV Imported file  Devices must support SNMP.  All devices (IP or IT) require licenses. HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 14 Physical Topology Set the background image Link status Alarm severity and number of alarms, which are updated in real time The physical topology vividly shows the structure of all network devices and their running status. HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 15 IP Topology Hierarchical Monitoring The IP topology view displays the following information:  Subnets  Layer 3 devices  Side-by-Side links between devices and IP links between  Layer 2 devices on subnets  LLDP links (LLDP protocol) devices and subnets (calculation based on the IP address and mask) Learn about the real-time time Layer 2 and Layer 3 network status by monitoring the IP topology view. HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 16 Smart User Management Client A Rights  eSight Different permissions are allocated to different users, and operation logs are recorded. Domain  A domain restricts the Domain A user management range. Domain B Period  The specified time segment and validity period can be configured for users. HUAWEI TECHNOLOGIES CO., LTD. Domain: devices that can be operated  Rights: operation permissions  Logs: user operations  Huawei Confidential Page 17 Client B All-round round Fault Monitoring IP device alarms  IT device alarms  Service alarms     Rich statistics reports Real-time time fault monitoring Abundant fault types Alarm severity 24-7 continuous fault monitoring  Real-time fault notification  Immediate remote notification   Email Policy Query Process Notify  Device connection and disconnection Interface connection and disconnection Linkage connection and disconnection SMS Sound HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 18 Simple and Clear Fault Management GUI Abundant fault types  Alarms can be combined, reducing the number of alarms on the GUI.  Alarm indicators blink to notify users of new alarms. The probable cause, additional information, and additional text help users to locate and rectify faults.  HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 19 Quick Fault Diagnosis Jump to the topology quickly HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 20 Quick Fault Diagnosis Jump to the device panel quickly HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 21 Overall Performance Management Performance counters of various types Graphs of various types Performance monitoring view updated continuously Historical performance data User-defined defined performance counters for third-party third devices HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 22 Performance Counters of Various Types Pre Pre-defined performance templates for third-  party devices Different pre-defined counter groups for  different devices HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 23 User-Defined Defined Performance Counters Collects specified performance counters by default. CPU usage Memory usage Interface traffic Multi-level thresholds (alarm severity and alarm count)  HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 24 Graphs of Various Types HUAWEI TECHNOLOGIES CO., LTD. Bar chart Meter panel Speedometer Graph Huawei Confidential Page 25 Performance Monitoring View Performance counters for different devices are displayed dis at the same time and updated continuously, helping users to understand the device status. HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 26 Historical Performance Data Performance counters for different devices are displayed at the same time. Users can use historical data for analysis. HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 27 User-Defined Defined Performance Counters Define performance counters for third third-party devices Define performance counters in the performance monitoring template. HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 28 Smart Reports eSight Report types Report data Report generation period Report distribution E Rich report types (Excel, PDF, and Word)  Comprehensive report presentation modes  User-defined report fields  Report design preview   Manual report  Periodical report (Period: Automatic distribution  Email distribution  day, week, month, quarter, half of a year, and year) HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 29 Report Customization Process  1 Use the report design tool to design a file 2 Upload the design file 4 Report data 3 Configure task information During file design, users can select report fields and presentation modes. HUAWEI TECHNOLOGIES CO., LTD.  During report export, users can specify report types. Huawei Confidential Page 30 Configuration File Management Backup  Immediate backup  Periodical backup  Backup triggered by configuration change alarms Comparison  Different colors indicate added rows, deleted rows, and modified rows. Restore  Use the source file to restore device configurations. HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 31 Backup Triggered by Con onfiguration Change Alarms 1. Enable the alarm-triggered backup function  for a device. Enable data back up function if device configurations change.  The function is disabled by default.   2. eSight receives an alarm.  The command is , for example ,set saveconfiguration delay 6 interval 31 cpu-limit 51. The parameters are optional. The alarm name is NE-triggered configuration backup. The device version is VRP V5R7C06 or later. 3. eSight backs up configuration files. HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 32 Smart Configuration Tool 1 2 Batch configuration and high-efficient network management  Table mode  CLI template–based design  Differentiated batch deployment CLI-based verification   Reduce configuration errors CLI mode 3 Huawei IT engineers take two days to configure 300 switches. Using the smart configuration tool, they take only 2 hours to configure 300 switches. HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 33 Template-based based Batch Configuration eSight System-view 1. Set parameters. 2. Select devices and verify commands. 3. Deliver commands. vlan batch 1 to 2 System-view vlan batch 1 to 2 If a command fails to be verifyed, the error information is displayed. VLAN 1 Templates can be used repeatedly, which improves the O&M efficiency. HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 34 Plan File–based based Differentiated Batch Configuration eSight system-view 1. Export the plan file. 2. Fill in the plan file. 3. Import file and verify commands. vlan 1 system-view vlan 2 VLAN 1 VLAN 2 4. Deliver commands. Differentiated batch configuration improves the O&M efficiency. HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 35 Hierarchical NMS Architecture eSight (Professional)  Headquarters Each subserver can run independently or be managed as a 4 Mbit/s 4 Mbit/s distributed subsystem. eSight (Professional or Standard)  On the server, the server administrator can Branch Branch access each subserver transparently and monitor the running status of each subserver. HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 36 Contents 1 Challenges for Enterprise Management Systems 2 Huawei eSight O&M Solution for Enterprises Overview Basic Network Management SLA Management MPLS Network Management WLAN Network Management 3 Configuration Introduction HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 37 Service-Oriented Oriented SLA Management, Visual Demonstration of Service Quality 1 Pre-define define the SLA service and encapsulate NQA parameters ICMP Jitter UDP Echo Video SLA 2 UDP Jitter Create an SLA task based on the pre-defined defined SLA service and perform the SLA task to calculate the SLA compliance 3 Use the compliance to demonstrate the service quality Relieving users of complicate NQA parameters, service service-oriented SLA management reduces the required skills and training costs. HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 38 SLA Task Execution Principles Predefined test instances  Total 10 test instances: ICMP Echo, ICMP Jitter, UDP Echo, UDP Jitter, TCP Connect, SNMP, DNS, DHCP, HTTP, and FTP Predefined SLA services  Built-in NQA  probes More than 20 predefined SLA services including voice, video, web Source device page browsing, and FTP Target device applications. Execution principles  Huawei device with built-in NQA probes as source devices.  Periodically create test instance on source devices to evaluate the service quality. Compliance and task counter alarms are supported.  Quick diagnosis for non-SLA tasks HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 39 Historical Data Providing a Basis for Network Optimization    Compliance data  Counter data  HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Save the original data for one month. Archive data that longer than over a month. Archive regularly  Hourly, daily, weekly or monthly Storage time of archived data  Hourly data: one year  Daily data: one year  Weekly data: three years  Monthly data: unlimited Data source  Hour -> Day -> Week -> Month Page 40 Intelligent Interaction with Smart Reporter   HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Export and print SLA service quality reports Export and print SLA task counter reports Page 41 Contents 1 Challenges for Enterprise Management Systems 2 Huawei eSight O&M Solution for Enterprises Overview Basic Network Management SLA Management MPLS Network Management WLAN Network Management 3 Configuration Introduction HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 42 Unified Monitoring on MPLS VPN Networks, One-Click Click Fault Diagnosis eSight Automatic discovery of Layer 3 VPN services from devices One-Click Fault Diagnosis Diagnosis Diagnosis on the connectivity of various links, including PE PE-PE, PE-CE, CE-CE, and PE-Remote CE links.  Various diagnosis tools, including UDP ping, VRF ping, LSP ping, and ICMP traceroute.  HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 43 Intelligent Interaction with SLA Quickly evaluate the MPLS VPN service quality and improve the O&M management capabilities. HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 44 Contents 1 Challenges for Enterprise Management Systems 2 Huawei eSight O&M Solution for Enterprises Overview Basic Network Management SLA Management MPLS Network Management WLAN Network Management 3 Configuration Introduction HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 45 WLAN Visual Management, Wizard Wizard-based Service Configuration eSight Engineers familiar with the service take about 100 minutes to enable services for 100 APs. With the help of eSight, engineers take only 10 minutes. Wizard Wizard-based configuration Service topology Position topology     Quickly identify invalid APs and shorten the fault diagnosis time. HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 46 Colors indicate information channels. The color depth indicates the signal strength. Invalid APs can be identified. The conflicted areas are displayed. Quick WLAN Service Deployment eSight Plan personnel  Device The AC and LSW can be automatically automatic discovered to eSight. Plan file  The smart configuration tool establishes discovery AC service channels and management LSW channels between the AC and the LSW. Installation personnel Fill in AP information Import the plan file  Configure basic AC attributes  Import APs in batches through the plan file.  APs download configurations from the AC. AP IT personnel HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 47 AP AP AP Operations eSight AC LSW AP AP Restarting APs  After APs are upgraded or commissioned, eSight can remotely restart APs in batches. Restoring APs to factory settings  If errors occur during AP configuration or commissioning, eSight can remotely restore APs to factory settings in batches. Replacing APs  After the faulty AP is replaced, service configurations are not affected. Diagnosing links  An AP can ping an upstream device to check the connectivity of the upstream link.  The AC can ping an AP to check the connectivity of the link between the AC and the AP.  AP HUAWEI TECHNOLOGIES CO., LTD. Note: Only Huawei WLAN devices are supported, and fit APs are controlled by the AC. Huawei Confidential Page 48 Contents 1 Challenges for Enterprise Management Systems 2 Huawei eSight O&M Solution for Enterprises Overview Basic Network Management SLA Management MPLS Network Management WLAN Network Management 3 Configuration Introduction HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 49 Configuration Edition Hardware Configuration Recommended Server Operating System + Database 60 CPU: dual-core 2.0 GHz or above Memory: 2 GB Hard disk: 20 GB Desktop-I3 2100 or above - Windows 7 (32-bit) + MySQL 5.5 (delivered with the product) 0-200 CPU: dual-core 2.0 GHz or above Memory: 4 GB Hard disk: 40 GB Note: A PC server is recommended. Number of Managed NEs Express Compact 200-500 Standard IBM X3650M3-Xeo quar-core E5506 2.13 GHz or above4G(1 x 4G)-2 x 300 GB Windows Server 2008 R2 (64-bit) + MySQL 5.5 or Windows Server 2008 R2 (64-bit) + Microsoft SQL Professional 500-2000 2000-5000 Professional CPU: 2 x dual-core 2 GHz or above Memory: 4 GB Hard disk: 60 GB Note: A PC server is recommended. 2G-320G or above 5000-20000 CPU: 2 x quar-core 2 GHz or above Memory: 8 GB Hard disk:120 GB Note: A PC server is recommended. IBM X3650M3-2*Xeon quar- Server 2008 R2 Standard core E5506 2.13 GHz or above -8G(2 x 4G)-3 x 300 GB CPU: 2 x quar-core 2 GHz or above Memory: 16 GB Hard disk: 250 GB Note: A PC server is recommended. IBM X3650M3-2*Xeon quar- CPU: 4 x quar-core 2 GHz or above IBMX3850X5-4*eight core E7- Memory: 32 GB 4820 2.0 GHz or above - Hard disk: 320 GB 32G(8 x 4 G)-8 x 300 GB core E5620 2.4 GHz or above -16G(2 x 8 G)-3 x 300 GB SUSE Linux 11 SP1 (64-bit) + Oracle 11g 11.1.0.6.0 Standard edition Note: A PC server is recommended. HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 50 How to Get a Trial Version Express edition (free of charge): Trial version (Compact, standard, or professional edition): HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 51 Thank You www.huawei.com