Preview only show first 10 pages with watermark. For full document please download

Esp_ii_48_technical_specification_sheet

   EMBED


Share

Transcript

T E C H N I C A L ESPII48 S P E C I F I C A T I O N S H E E T 48/96 CHANNELS / 24 SCENE MASTERS MEMORY LIGHTING CONTROL CONSOLE DESCRIPTION Memory: Power supply: Consumption: Connector: 256 Kbytes Universal 100~240VAC ±10% , 47~63 Hz 40W typical IEC 3-pin with integral fuse, switch and mains filter Fuse: 2A M205/240V MIDI in: 5-pin DIN socket DMX out: USITT DMX-512/1990 protocol (RS-485 standard)/ AXR 5-pin socket Analogue out: 0 ~ +10V DC/ Socapex 337 socket (option) Desk lamp outputs: 2  12V current limited, AXR 3-pin socket; 10W max. Display: 32 character, 2 line LCD, green backlight Dimensions: 1180mm (W)  490mm (D)  108mm (H) Net/shipping weight: 15/18 kg The ESPII 48 console is primarily designed for the control of devices featuring DMX input circuitry such as dimmers racks and colour scrollers. Units requiring an analogue input (0 to +10 volts) can also be controlled if the console is fitted with optional analogue outputs. FEATURES * DMX 512 output to control dimmers, moving lights and colour scrollers * Wide mode doubles the number of channel faders to 96 channels * Add/solo functions on all channels and scene masters * Three proportional softpatches to 512 DMX channels * LCD window for operator feedback * Up to 498 memories * Up to 30 scene pages * Up to 30 chases * Live or blind editing SUPPLIED ACCESSORIES * Easy recording of scenes • 2m IEC to Clipsal 463 power cable (export models may vary) • Operating manual * Timed dipless crossfades ORDERING INFORMATION MODEL/PART * Console linking to JANDS STAGE / ESP II / EVENT / EVENT PLUS consoles • • • • • • • * CE approved: EN50081-1, EN50082-1, EN60950 * OVERALL SPECIFICATIONS Control channels: Scene masters: PART NO. • ESP II 48 48 (normal), 96 (wide) 24 JND-ESPII48 M-card module JND-OPM VDU interface/M-card module JND-OPVM-VGA M-card JND-MCARD Floppy disk drive module (DOS format) JND-OPFD-ESPII Analogue output module JND-OPA60 Desk lamp CAE-18XR/CAE-18XR-Hi Flightcase JND-FC-ESPII48 PRESET 1 10 10 10 8 8 8 6 6 6 4 4 4 2 2 2 0 0 0 PRESET 2 69 22 70 23 71 24 10 10 10 8 8 8 6 6 6 4 4 4 2 2 2 0 0 0 25 72 73 26 74 27 75 28 76 29 77 30 31 78 79 32 80 33 34 81 82 35 36 83 37 84 85 38 86 39 87 40 88 41 42 89 90 43 44 91 ADD D.B.O. LATCH SCENE MASTERS INHIBIT SOLO OFF OFF FLASH 10 8 10 CURSOR 6 4 2 D.B.O. OFF REVERSE SCENE 4 ON 2 0 0 MODE 10 10 8 8 6 6 4 4 2 2 SETUP RANDOM EXIT 4 15 16 17 18 19 20 21 22 23 24 RECORD FUNCTION 0 CHASE 45 93 46 94 47 95 48 96 6 VALUE EDIT ALL 8 RATE ASSIGN 92 48/96 CHANNELS / 24 SCENE MASTERS MEMORY LIGHTING CONTROL CONSOLE * 4  option ports (back panel) FX 0 XF P1 ESP II 48 console P2 FLASH MASTER ESPII24 48 * Effects (FX) section T E C H N I C A L ESPII48 S P E C I F I C A T I O N S H E E T 48/96 CHANNELS / 24 SCENE MASTERS MEMORY LIGHTING CONTROL CONSOLE ARCHITECTS & ENGINEERS SPECIFICATION Electronics The control surfaces shall be scratch-resistant 0.25mm Lexan with legends reverse silk-screened from behind. All operator controls and displays shall be provided on the top operating surface of the console. The chassis shall have sufficient ventilation holes to allow adequate convection cooling of the power supply, provided the ambient temperature does not exceed 40˚C (104˚F). The console shall provide control of up to 48 control channels (96 in wide mode) via the industry standard USITT DMX-512/1990 protocol. The DMX output socket on the back panel shall be a 5-pin AXR and the output voltages shall conform to standard RS-485 balanced serial data transmission. The console shall have a standard MIDI In 5-pin DIN connection. Four (4) rear panel option slots shall allow the fitting of optional modules including M card/ video output/ analogue outputs and floppy disc drive. The console shall have two (2) banks of preset faders and a flash button with an integral light emitting diode (LED) per channel to allow direct manual control of stage lighting intensity. In addition a liquid crystal display (LCD) shall be provided to enable the operator to view operating parameters and to edit in formation. The console shall be the JANDS ESP II 48. A memory capacity of no less than 256 Kbytes is required. The memory shall be battery-backed to prevent memory loss when switched off. The battery shall have a life of at least four (4) years. 108 mm 490 mm 0 2 4 6 0 8 2 10 4 6 8 10 The console shall incorporate design techniques and electronic filters to comply with Australian and European Union directives on electrical safety and electromagnetic compatibility (EMC). 0 2 MASTER 6 4 8 10 6 SCENE ALL 8 D.B.O. OFF REVERSE FLASH OFF SOLO LATCH 0 2 4 XF 0 10 4 6 8 10 2 87 39 86 38 85 FX 37 CHASE RANDOM MODE RECORD EXIT FUNCTION SETUP EDIT VALUE CURSOR OFF 81 33 0 2 4 6 8 30 24 78 10 31 79 32 80 An error message shall be displayed to the operator should the software malfunction or be corrupted. ON 34 82 35 83 RATE ASSIGN 36 84 0 2 4 6 8 10 PRESET 2 0 2 4 6 8 10 PRESET 1 The operating software of the console shall incorporate diagnostic test routines that exercise the different systems on the CPU card. These test routines shall indicate to the operator (using LEDs and/or displays) the result (pass/fail) of the tests. P1 40 88 P2 41 89 Operation ADD 42 FLASH 90 43 91 D.B.O. INHIBIT 44 92 Three (3) proportional DMX soft-patches shall be available. DESKLAMP 45 93 46 94 47 95 48 96 The console shall be factory tested and cyclically burned-in for a minimum of 24 hours. 16 23 15 70 22 14 69 21 13 68 0 2 4 6 8 10 20 67 19 66 18 10 8 6 4 2 0 10 8 6 4 2 0 65 17 4 9 DMX-512 OUT DESKLAMP 7 1 54 6 53 Specifications subject to change without notice. Manufactured by Jands Electronics Pty Ltd ACN 001 187 837. Note: While all due care has been taken in the preparation of this document, Jands Electronics shall not be liable for any inaccuracies or omissions which may occur herein. TSS-ESPII48-0108-05 POWER Jands Electronics Pty Ltd 40 Kent Road Mascot NSW 2020 Australia Phone: +61 2 9582 0999 Fax: +61 2 9582 0909 Internet: [email protected] ESPII48 100~240VAC 50~60Hz 0.5A FUSE: 2A M205/240V 5 52 4 51 3 50 2 49 1 The console shall be a free standing device and be 1180mm wide, 490mm deep and 108mm high. The console shall be constructed of 1.2mm steel, and shall be provided with a removable 1.2mm aluminium base for access to internal electronics. All metal surfaces shall be properly treated and finished in powdercoat or zinc dichromate passivating. 2 55 8 3 56 Mechanical Manufactured in Australia by: JANDS Electronics Pty Ltd ACN 001 187 837 11 10 9 8 7 6 5 12 59 11 58 57 10 SCENE MASTERS 0 0 The console shall feature a desk linking function. MIDI IN 12 64 16 63 15 62 14 61 2 2 13 4 4 60 6 6 0 0 8 2 2 8 4 4 10 6 PRESET 2 8 6 10 10 8 PRESET 1 10 A 12V current limited supply terminated on a 3-pin AXR socket shall be provided on the back panel to power a pair of optional desk lamps. 1180 mm 17 18 19 SCENE MASTERS 71 24 72 0 2 4 6 8 10 0 2 4 6 8 10 25 73 26 20 74 27 21 75 The console shall operate from a single-phase supply of 100 to 240 volts AC ±10% with a supply frequency of 47 to 63 Hz and shall not draw more than 50 watts of power from a normal power outlet. The power inlet shall be a switched and filtered IEC mains socket with integral fuse, located on the back panel of the console. The power supply shall be a universal-type switched mode supply requiring no changing of internal links to accommodate different supply voltages. 48/96CHANNELS / 24 SCENE MASTERS MEMORY LIGHTING CONTROL CONSOLE 28 22 76 29 23 77 Electrical