Preview only show first 10 pages with watermark. For full document please download

Ethernet Standard Plc C0-11dd1e-d $149.00 8 Dc Input/6 Sinking Dc Output Micro Plc

   EMBED


Share

Transcript

Prices as of October 15, 2015. Check Web site for most current prices. Ethernet Standard PLC C0-11DD1E-D $149.00 C0-11DD1E-D Built-in I/O Specifications - Inputs Inputs per Module Operating Voltage Range Input Voltage Range Input Current Maximum Input Current Input Impedance ON Voltage Level OFF Voltage Level Minimum ON Current Maximum OFF Current OFF to ON Response ON to OFF Response Status Indicators Commons 8 DC Input/6 Sinking DC Output Micro PLC Wiring Diagram C0-11DD1E-D C0-11D D1E--D D 24VDC C1 1 + X1 X2 2 RUN R UN X3 3 RUN + PWR X4 4 STOP S TOP ERR C2 2 X5 5 LNK/ACT ETHER NET 100MBIT X6 6 + X7 7 X8 8 RX2 RS-232 RS 232 RS-485 RS-485 485 5 L Y3 3 L Y4 4 L C0-11DD1E-D Built-in I/O Specifications - Outputs Outputs per Module Operating Voltage Range Output Voltage Range Maximum Output Current Minimum Output Current Maximum Leakage Current On Voltage Drop Maximum Inrush Current OFF to ON Response ON to OFF Response Status Indicators Commons External DC Power Required 5 - 27VDC L Y6 6 L +V V LG G + Y5 5 5 - 27VDC + RX X3 RX3 L Y2 2 C4 4 + _ TX3 TX X3 Y1 + C3 3 PORT2 TX2 PO ORT3 PORT3 + PORT1 24VDC NOTE: When using Ethernet Standard PLCs, you must use CLICK programming software version V2.00 or later. Equivalent Input Circuit Internal Module Circuitry + Optical Isolator INPUT X1-X4 Typical + 24 VDC Current Consumption at 24VDC Terminal Block Replacement Part No. Weight To X2-X4 commons + 6 5-27 VDC 4-30 VDC 0.1 A/point; C3: 0.4 A/common, C4: 0.2 A/common 0.2 mA 0.1 mA @ 30.0 VDC 0.5 VDC @ 0.1 A 150 mA for 10 ms Max. 0.5 ms Max. 0.5 ms Logic Side (6 points, red LED) 2 (4 points/com & 2 points/com) 20-28 VDC Maximum @ 60 mA (All Points On) General Specifications C1 COM Optical Isolator INPUT X5-X8 Typical + 8 (Sink/Source) 24 VDC 21.6 - 26.4 VDC Typ 6.5 mA @ 24 VDC 7.0 mA @ 26.4 VDC 3.9 kq @ 24 VDC > 19 VDC < 2 VDC 4.5 mA 0.5 mA Typ 5 µs Max 20 µs Typ 5 µs Max 20 µs Logic Side (8 points, green LED) 2 (4 points/common) Isolated 140 mA C0-16TB 5.0 oz (140 g) 24 VDC C2 COM C0-11DD1E-D Temperature Derating Chart To X6-X8 commons C0-11DD1E-D 8 Equivalent Output Circuit +V + + L Optical Isolator OUTPUT Y1 5 - 27 VDC * Points 24 VDC Inputs 6 Internal Module Circuitry Outputs 4 * 2 High response circuit ZIPLink Pre-Wired PLC Connection Cables and Modules ZL-RTB20 20-pin feed-through connector module 0 + L Optical Isolator OUTPUT Y2-Y4 5 - 27 VDC * High response circuit 0 32 10 50 20 68 30 85 40 45 50 55 °C 104 113 122 131 °F Surrounding Air Temperature (°C/°F) * Use every other input. C3 COM + L Optical Isolator OUTPUT Y5-Y6 5 - 27 VDC * High response circuit C4 COM 20-pin connector cable ZL-C0-CBL20 (0.5 m length) ZL-C0-CBL20-1 (1.0 m length) ZL-C0-CBL20-2 (2.0 m length) Note: C3 & C4 are not internally connected. * Zener Diode Power Dissipation: 200 mW Book 1 (14.3) eCL-68 CLICK PLCs 1-800-633-0405