Preview only show first 10 pages with watermark. For full document please download

Eu V5x 01 Cover

   EMBED


Share

Transcript

1702-1V1702-EU Commercial Air Conditioners 2017/2018 VRF V5X Series 50Hz Commercial Air Conditioner Division Midea Group Add.: Midea Headquarters Building, 6 Midea Avenue, Shunde, Foshan, Guangdong, China Midea CAC After-service Application Midea CAC News Application Postal code: 528311 Tel: +86-757-26338346 Fax: +86-757-22390205 cac.midea.com global.midea.com Note: Product specifications change from time to time as product improvements and iOS Version Android Version iOS Version developments are released and may vary from those in this document. Midea CAC Midea CAC is a key division of the Midea Group, a leading producer of consumer appliances and provider There are three production bases: Shunde, Chongqing and Hefei. of heating, ventilation and air conditioning solutions. Midea CAC has continued with the tradition of MCAC Shunde: 38 product lines focusing on VRF, Split Products, Heat Pump Water Heaters, and AHU/FCU. innovation upon which it was founded, and emerged as a global leader in the HVAC industry. A strong MCAC Chongqing: 14 product lines focusing on Water Cooled Centrifugal/Screw/Scroll Chillers, Air Cooled drive for advancement has created a groundbreaking R&D department that has placed Midea CAC at the Screw/Scroll Chillers, and AHU/FCU. forefront of a competitive field. Through these independent efforts and joint cooperation with other MCAC Hefei: 11 product lines focusing on VRF, Chillers, and Heat Pump Water Heaters. global enterprises, Midea has supplied thousands of innovative solutions to customers worldwide. 2016 2014-2015 Acquired 80% stake in Clivet Win FIFA World Cup Stadiums project in Brazil Beira Rio, Olympic Games Stadiums project in Brazil Rio de Janeiro and Africa games Stadiums project in Congo Brazzaville successively 2014 Midea Company Introduction Midea CAC Introduction 2011-2014 Launched the All DC Inverter V5X globally, outstanding product performance helps Midea leading VRF market Launched the DC Inverter V4 Plus Series successively, complete product lines help Midea successfully enter 2011-2012 the mainstream VRF market 2009 J.V. with Carrier LA and Carrier India successively 2008 Launched the DC Inverter V4 globally 2000-2001 1999 Developed DC inverter technology with Toshiba Cooperated with Toshiba and Copeland, enter VRF field Technology Inspires Possibilities OUTDOOR UNIT LINEUP HP 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 Single unit Multi combination 03 04 88 Technology Inspires Possibilities OUTDOOR UNITS High Efficiency VRF V5 X SYSTEM High Reliability Wide Application Range V5X Introduction Enhanced Comfort Easy Installation and Service 05 06 Technology Inspires Possibilities High Efficiency High Efficiency Heat Exchanger Newly designed fins enlarge the heat exchange area and decrease air resistance, enhance heat exchange performance and save more energy. High EER and COP DC compressors and fan motors together with a high-efficiency heat exchanger combine to give the V5 X Series top-class energy efficiency in cooling and heating. Hydrophilic fins and internally threaded copper pipes optimize heat exchange efficiency. δ design increases the degree of liquefaction in the condenser and improves heat-exchange efficiency. 5.60 5.30 4.70 4.90 4.50 4.30 4.30 4.10 3.90 3.86 4.80 4.60 4.25 3.74 4.12 4.03 Original design 8HP 10HP 12HP 14HP 16HP 18HP 20HP 22HP 8HP 10HP 12HP 14HP 16HP 18HP 20HP Gas 22HP Liquid New design EER 75°C 75°C COP Gas Liquid 37°C 43°C All DC Inverter Compressors At the heart of the V5 X Series outdoor unit lies a world-leading DC inverter scroll compressor. The compressor's innovative design and numerous high performance features reduce power consumption by 25%. Gas Gas Gas-Liquid Liquid Liquid δ design More compact, weight reduced by 50% New structure enhances mid-frequency performance Newly Designed Fan A new blade with sharp edges and a slight curve increases the airflow rate and lowers vibration and airflow resistance. Specially designed scroll profile for R410A Advanced permanent magnet DC motor improves low frequency band performance All DC Fan Motors Fan speed is controlled according to the system pressure and system load, minimizing energy consumption. Precise Control Multiple solenoid valves ensure precise temperature control, stable and efficient operation, and improved comfort. High 15-step vector control Dual EXVs Control Dual EXVs in one system, each EXV part achieves 480 Pulse rate to precisely adjust refrigerant flow. Low 07 08 Technology Inspires Possibilities Wide Application Range High Reliability Wide Capacity Range Duty Cycling The V5 X series has an extensive range of capacities, from 8HP to 88HP, meeting all customer requirements from small to large buildings. Duty cycling equalizes the running time of the outdoor units in a multiple-unit system and of the compressors in each unit, significantly extending compressor lifespan. 1 Wide Range of Indoor Units Midea provides 12 types and more than 100 models of VRF indoor units to meet varied customer requirements in a wide range of locations including shopping malls, hospitals, office buildings, hotels and airports. 2 3 4 4 1 2 3 3 4 1 2 2 3 4 1 Wide Operation Range V5X Series operates stably under extreme conditions, ranging from minus 20°C to 48°C. Backup In a multi-unit system, if one module fails, the other modules provide backup so that the system can continue operating. 50°C 48°C 40°C Precise Oil Control Technology 30°C 24°C 20°C Five stages of oil control technology ensure all outdoor compressor oil is always kept at a safe level, eliminating any compressor oil shortage problems. 10°C 0°C The 1st stage: Compressor internal oil separation. The 2nd stage:High-efficiency centrifugal oil separator (with separation efficiency of up to 99%) ensures that oil is -5°C COOLING MODE -10°C -20°C -20°C separated from the discharge gas and returned to the compressors in a timely fashion. The 3rd stage:Oil balance pipes between compressors ensure even oil distribution to keep compressors running normally. The 4th stage: Oil balance pipes among modules ensure even oil distribution among modules. The 5th stage: Auto oil return program monitors the running time and system status to ensure reliable oil return. HEATING MODE Long Piping Capability Largest height difference between indoor and outdoor units - ODU up (down) Largest height difference between indoor units 90m* 90m (110m) 30m *The longest length after first branch is 40m as standard but can be extended to up to 90m under certain conditions. Please contact your local Midea dealer for further information. 09 2nd stage Level difference between IDU~IDU 30m Longest length after first branch 175m (200m) Level difference between IDU~ODU 110m Longest length - actual (equivalent) 1000m 90m Total piping length Capability Longest actual piping length 175m Piping length 4th stage 5th stage 1st stage 3rd stage 10 Technology Inspires Possibilities Easy Installation and Service Enhanced Comfort Night Silent Mode Simple Communication Wiring The night silent mode feature, which is easily configured on the outdoor unit's PBC, includes various scheduling options that can be used to reduce noise levels at times when low noise operation is required. Outside Indoor centralized controller can be connected to either the indoor or the outdoor units. A single set of wiring can be used for system and network communication, making installation quicker and easier. Inside X Y E X Y E P Q E P Q E P Q E P Q E P Q E Quiet 15 dB(A) reduction 5 Auto Addressing 6 4 Outdoor unit can distribute addresses to indoor units automatically. Intelligent Defrosting Technology 2 Remote and wired controllers can be used to query or modify each indoor unit's address. Intelligent defrosting Heating capacity The intelligent defrosting program calculates the time required for defrosting according to the actual system status, eliminating heat losses from unnecessary defrosting. A specialized defrosting valve reduces time required for defrosting to as little at four minutes. 7 3 8 1 9 Usual defrosting 10 Rotatable Electric Control Box t min ∆t The newly designed rotating control box can be rotated up to 150 degrees to provide access to the pipeline system for inspection and maintenance without the need to remove the control box. Time Max. 150o Rapid Cooling or Heating Fluctuation of room temperature Temp The DC inverter compressor reaches full capacity rapidly, providing quicker cooling or heating with lower levels of temperature fluctuation during the cooling/heating operation. 1 Time Cooling operation 11 Inverter Non-Inverter 2 Easy Maintainence Special features that increase ease of maintenance include a control box inspection window for viewing the system status, a self-diagnosis function that speeds fault analysis, and the positioning of the compressor adjacent to the casing, which simplifies inspection and enables valve or compressor parts to be replaced easily. 12 Technology Inspires Possibilities Anti-corrosion Protection Outdoor units are given anti-corrosion treatment for non-extreme conditions as standard and can also be customized with heavy anti-corrosion treatment on steel sheets, grills, coil fins, electric control box case and screws/bolts for surface protection against corrosive air, acid rain and saline air (for installations in coastal regions) to extend overall useful life. Copper Heat Exchanger Aluminum Foil Standard products: 72h of neutral salt mist Standard products: 24h of neutral salt mist Heavy anti-corrosion products: 1000h of neutral salt mist 140h of acid salt mist Heavy anti-corrosion products: 120h of neutral salt mist Outside The integrity of the anti-corrosion treatment is ensured by subjecting major components and parts to salt mist testing, moisture and heating testing and light aging testing. Motor Standard products: 72h of neutral salt mist Heavy anti-corrosion products: 240h of neutral salt mist Painted Sheet Metal Standard products: 500h of neutral salt mist 1000h of moisture and heating test 500h of light aging test Heavy anti-corrosion products: 1000h of neutral salt mist 2000h of moisture and heating test 720h of light aging test Electric Control Box Case Standard products: 96h of neutral salt mist Heavy anti-corrosion products: 240h of neutral salt mist Compressor / Motor Bolts Screws / Bolts / Gaskets Standard products: 300h of neutral salt mist Standard products: 72h of neutral salt mist Heavy anti-corrosion products: 168h of neutral salt mist Heavy anti-corrosion products: 720h of neutral salt mist 13 14 Technology Inspires Possibilities Specifications Specifications HP Model V/Ph/Hz Power supply kW Cooling Capacity kW Power input EER ESEER kW Heating Capacity kW Power input COP Connectable Total capacity indoor unit Max. quantity Compressor Type Quantity Fan motor Type Quantity Pa Max Static Pressure Pa Refrigerant Type kg Factory charging ton TCO2eq Liquid pipe Pipe mm connections Gas pipe mm mm Oil balance pipe Air flow rate m3/h dB(A) Sound pressure level dB(A) Sound power level mm Net dimensions (W×H×D) mm Packed dimensions (W×H×D) kg Net weight kg Gross weight Operating temperature range °C 8 MV5-X252W/V2GN1 HP Model V/Ph/Hz Power supply kW Cooling Capacity kW Power input EER ESEER kW Heating Capacity kW Power input COP Connectable Total capacity indoor unit Max. quantity Compressor Type Quantity Fan motor Type Quantity Pa Max Static Pressure Pa Refrigerant Type kg Factory charging ton TCO2eq Liquid pipe Pipe mm connections Gas balance pipe mm mm Oil balance pipe Air flow rate m3/h dB(A) Sound pressure level dB(A) Sound power level mm Net dimensions (W×H×D) mm Packed dimensions (W×H×D) kg Net weight kg Gross weight Operating temperature range °C 16 MV5-X450W/V2GN1 10 MV5-X280W/V2GN1 12 MV5-X335W/V2GN1 14 MV5-X400W/V2GN1 380-415/3/50 25.2 5.36 4.70 8.25 27.0 4.82 5.60 13 1 1 9 18.79 Φ12.7 Φ25.4 12000 58 70 219 234 45.0 10.98 4.10 7.20 50.0 10.87 4.60 26 13 27.14 Φ15.9 Φ31.8 14000 62 74 297 315 28.0 33.5 6.22 7.79 4.50 4.30 7.90 7.54 31.5 37.5 5.94 7.65 5.30 4.90 50~130% of outdoor unit capacity 16 20 DC inverter 1 1 DC motor 1 1 20 (default) 60 (customized) R410A 9 11 18.79 22.97 Φ12.7 Φ15.9 Φ25.4 Φ28.6 Φ6.35 12000 12000 59 60 71 72 990×1635×790 1055×1805×855 219 237 234 252 Cooling: -5-48; Heating: -20-24 18 MV5-X500W/V2GN1 20 MV5-X560W/V2GN1 380-415/3/50 50.0 56.0 12.82 14.51 3.90 3.86 7.36 7.28 56.0 63.0 13.18 15.29 4.25 4.12 50~130% of outdoor unit capacity 29 33 DC inverter 2 DC motor 2 20 (default) 60 (customized) R410A 13 16 27.14 33.41 Φ19.1 Φ19.1 Φ31.8 Φ31.8 Φ6.35 16000 16000 63 63 75 75 1340×1635×790 1405×1805×855 305 340 323 358 Cooling: -5-48; Heating: -20-24 40.0 9.30 4.30 7.54 45.0 9.38 4.80 23 2 2 13 27.14 Φ15.9 Φ31.8 14000 62 74 1340×1635×790 1405×1805×855 297 315 22 MV5-X615W/V2GN1 61.5 16.44 3.74 7.04 69.0 17.12 4.03 36 16 33.41 Φ19.1 Φ31.8 16000 63 75 340 358 Notes: Capacities are based on the following conditions: Cooling: Indoor temperature 27oC DB/19oC WB; Outdoor temperature 35oC DB/24oC WB; Heating: Indoor temperature 20oC DB/15oC WB; Outdoor temperature 7oC DB/6oC WB. Piping length: Interconnecting piping length is 7.5m, level difference is zero. Connection piping diameter of single-unit is the stop valve diameter of the unit. Connection piping diameter of multi-unit is the main pipe connecting to the first indoor branch joint, is case of the total equivalent liquid length is less than 90m. If the total equivalent liquid length is more than 90m, please refer to technical manual to choose the connection piping diameter. Sound values are measured in a semi-anechoic room, at a position 1m in front of the unit and 1.3m above the floor. 15 HP Model Combined type Power supply V/Ph/Hz Capacity Cooling kW Power input kW EER ESEER Capacity kW Heating Power input kW COP Connectable Total capacity Max. quantity indoor unit Compressor Type Quantity Type Fan motor Quantity Type Refrigerant Factory charging kg TCO2eq ton Liquid pipe mm Pipe mm connections Gas pipe m3/h Oil balance pipe Air flow rate m3/h Sound pressure level dB(A) Sound power level dB(A) Net dimensions (W×H×D) mm Packed dimensions (W×H×D) mm Net weight kg Gross weight kg Operating temperature range °C 24 MV5-X670W/V2GN1 12HP×2 26 MV5-X730W/V2GN1 10HP+16HP 67.0 15.58 4.30 7.54 75.0 15.31 4.90 73.0 17.20 4.24 7.47 81.5 16.81 4.85 39 43 2 3 2 3 11×2 22.97×2 Φ15.9 Φ28.6 9+13 18.79+27.14 Φ19.1 Φ31.8 24000 64 76 (990×1635×790)×2 (1055×1805×855)×2 237×2 252×2 26000 65 77 219+297 234+315 32 30 28 MV5-X780W/V2GN1 MV5-X840W/V2GN1 MV5-X895W/V2GN1 10HP+22HP 10HP+20HP 10HP+18HP 380-415/3/50 89.5 84.0 78.0 22.67 20.73 19.04 3.95 4.05 4.10 7.42 7.52 7.50 100.5 94.5 87.5 23.06 21.23 19.12 4.36 4.45 4.58 50~130% of outdoor unit capacity 53 50 46 DC inverter 3 3 3 DC motor 3 3 3 R410A 9+16 9+16 9+13 18.79+33.41 18.79+33.41 18.79+27.14 Φ19.1 Φ19.1 Φ19.1 Φ31.8 Φ31.8 Φ31.8 Φ6.35 28000 28000 28000 65 65 65 77 77 77 1055×1805×855+1405×1805×855 1055×1805×855+1405×1805×855 219+340 219+340 219+305 234+323 234+358 234+358 Cooling: -5-48; Heating: -20-24 34 MV5-X950W/V2GN1 12HP+22HP 95.0 24.23 3.92 7.38 106.5 24.77 4.30 56 3 3 11+16 18.79+33.41 Φ19.1 Φ31.8 28000 65 77 237+340 252+358 46 44 42 40 38 36 HP MV5-X1000W/V2GN1 MV5-X1065W/V2GN1 MV5-X1115W/V2GN1 MV5-X1175W/V2GN1 MV5-X1230W/V2GN1 MV5-X1285W/V2GN1 Model 12HP×2+22HP 22HP×2 20HP+22HP 18HP+22HP 16HP+22HP 18HP×2 Combined type Power supply V/Ph/Hz 380-415/3/50 128.5 123.0 117.5 111.5 106.5 Capacity Cooling kW 100.0 32.03 32.89 30.95 29.26 27.42 Power input kW 25.64 4.01 3.74 3.80 3.81 3.88 EER 3.90 7.49 7.04 7.08 7.10 7.32 ESEER 7.36 144.0 138.0 132.0 125.0 119.0 Capacity 112.0 kW Heating 32.43 34.24 32.41 30.30 27.99 Power input 26.35 kW 4.44 4.03 4.07 4.13 4.25 COP 4.25 Connectable Total capacity 50~130% of outdoor unit capacity 64 64 64 64 Max. quantity 63 59 indoor unit Compressor Type DC inverter Quantity 4 Type Fan motor DC motor Quantity 4 Type Refrigerant R410A 11×2+16 16×2 16×2 13+16 Factory charging 13+16 13×2 kg TCO2eq ton 27.14×2 27.14+33.41 27.14+33.41 33.41×2 33.41×2 22.97×2+33.41 Liquid pipe mm Pipe Φ19.1 mm connections Gas pipe Φ38.1 mm Φ6.35 Oil balance pipe m3/h Air flow rate 32000 30000 32000 32000 32000 40000 Sound pressure level dB(A) 66 78 Sound power level dB(A) (1340×1635×790)×2 Net dimensions (W×H×D) mm ((990×1635×790)×2+1340×1635×790 (1405×1805×855)×2 340×2 Packed dimensions (W×H×D) mm (1055×1805×855)×2+1405×1805×855 340×2 340×2 305+340 315+358 Net weight 305×2 kg 237×2+340 Gross weight kg 323×2 315+358 323+358 358×2 358×2 252×2+358 Operating temperature range °C Cooling: -5-48; Heating: -20-24 Notes: Capacities are based on the following conditions: Cooling: Indoor temperature 27oC DB/19oC WB; Outdoor temperature 35oC DB/24oC WB; Heating: Indoor temperature 20oC DB/15oC WB; Outdoor temperature 7oC DB/6oC WB. Piping length: Interconnecting piping length is 7.5m, level difference is zero. Connection piping diameter of single-unit is the stop valve diameter of the unit. Connection piping diameter of multi-unit is the main pipe connecting to the first indoor branch joint, is case of the total equivalent liquid length is less than 90m. If the total equivalent liquid length is more than 90m, please refer to technical manual to choose the connection piping diameter. Sound values are measured in a semi-anechoic room, at a position 1m in front of the unit and 1.3m above the floor. 16 Technology Inspires Possibilities Specifications HP Model Combined type V/Ph/Hz Power supply Capacity kW Cooling Power input kW EER ESEER Capacity kW Heating Power input kW COP Connectable Total capacity Max. quantity indoor unit Compressor Type Quantity Type Fan motor Quantity Type Refrigerant Factory charging kg TCO2eq ton Liquid pipe mm Pipe mm connections Gas pipe mm Oil balance pipe m3/h Air flow rate Sound pressure level dB(A) Sound power level dB(A) Net dimensions (W×H×D) mm Packed dimensions (W×H×D) mm Net weight kg Gross weight kg Operating temperature range °C Specifications 48 MV5-X1345W/V2GN1 10HP+16HP+22HP 134.5 33.64 4.00 7.48 150.5 33.93 4.44 9+13+16 18.79+27.14+33.41 Φ19.1 Φ38.1 42000 219+297+340 234+315+358 54 52 MV5-X1510W/V2GN1 MV5-X1455W/V2GN1 10HP+22HP×2 10HP+20HP+22HP 380-415/3/50 151.0 145.5 139.5 39.11 37.17 35.49 3.86 3.91 3.93 7.28 7.37 7.40 169.5 163.5 156.5 40.19 38.36 36.24 4.22 4.26 4.32 50~130% of outdoor unit capacity 64 DC inverter 5 DC motor 5 R410A 9+16×2 9+16×2 9+13+16 18.79+33.41×2 18.79+33.41×2 18.79+27.14+33.41 Φ22.2 Φ22.2 Φ19.1 Φ41.3 Φ38.1 Φ41.3 Φ6.35 44000 44000 44000 67 79 990×1635×790+(1340×1635×790)×2 1055×1805×855+(1405×1805×855)×2 219+340×2 219+340×2 219+305+340 234+323+358 234+358×2 234+358×2 Cooling: -5-48; Heating: -20-24 50 MV5-X1395W/V2GN1 10HP+18HP+22HP 56 MV5-X1565W/V2GN1 12HP+22HP×2 156.5 40.68 3.85 7.18 175.5 41.90 4.19 11+16×2 22.97+33.41×2 Φ22.2 Φ41.3 44000 237+340×2 252+358×2 HP Model Combined type Power supply V/Ph/Hz Capacity Cooling kW Power input kW EER ESEER Capacity kW Heating Power input kW COP Connectable Total capacity Max. quantity indoor unit Compressor Type Quantity Type Fan motor Quantity Type Refrigerant Factory charging kg TCO2eq ton Liquid pipe mm Pipe mm connections Gas pipe mm Oil balance pipe m3/h Air flow rate Sound pressure level dB(A) Sound power level dB(A) Net dimensions (W×H×D) mm Packed dimensions (W×H×D) mm Net weight kg Gross weight kg °C Operating temperature range 70 MV5-X1960W/V2GN1 10HP+16HP+22HP×2 196.0 50.09 3.91 7.37 219.5 51.06 4.30 9+13+16×2 18.79+27.14+33.41×2 58000 219+297+340×2 234+315+358×2 76 74 MV5-X2125W/V2GN1 MV5-X2070W/V2GN1 10HP+22HP×3 10HP+20HP+22HP×2 380-415/3/50 212.5 207.0 201.0 55.55 53.62 51.93 3.83 3.86 3.87 7.12 7.28 7.30 238.5 232.5 225.5 57.31 55.48 53.36 4.16 4.19 4.23 50~130% of outdoor unit capacity 64 DC inverter 7 DC motor 7 R410A 9+16×3 9+16×3 9+13+16×2 18.79+33.41×3 18.79+27.14+33.41×2 18.79+33.41×3 Φ25.4 Φ44.5 Φ6.35 60000 60000 60000 69 81 (990×1635×790)+(1340×1635×790)×3 (1055×1805×855)+(1405×1805×855)×3 219+340×3 219+340×3 219+305+340×2 234+323+358×2 234+358×3 234+358×3 Cooling: -5-48; Heating: -20-24 78 MV5-X2180W/V2GN1 12HP+22HP×3 86 84 MV5-X2405W/V2GN1 MV5-X2345W/V2GN1 20HP+22HP×3 18HP+22HP×3 380-415/3/50 240.5 234.5 63.84 62.15 3.77 3.77 7.05 7.05 270.0 263.0 66.66 64.54 4.05 4.07 50~130% of outdoor unit capacity 64 DC inverter 8 DC motor 8 R410A 16×4 13+16×3 27.14+33.41×3 33.41×4 Φ25.4 Φ44.5 Φ6.35 64000 64000 70 82 (1340×1635×790)×4 (1405×1805×855)×4 340×4 305+340×3 323+358×3 358×4 Cooling: -5-48; Heating: -20-24 88 MV5-X2460W/V2GN1 22HP×4 72 MV5-X2010W/V2GN1 10HP+18HP+22HP×2 218.0 57.12 3.82 7.11 244.5 59.02 4.14 11+16×3 22.97+33.41×3 60000 237+340×3 237+340×3 252+358×3 68 66 64 62 60 58 HP MV5-X1615W/V2GN1 MV5-X1680W/V2GN1 MV5-X1730W/V2GN1 MV5-X1790W/V2GN1 MV5-X1845W/V2GN1 MV5-X1900W/V2GN1 Model 12HP×2+22HP×2 22HP×3 20HP+22HP×2 18HP+22HP×2 16HP+22HP×2 18HP×2+22HP Combined type Power supply V/Ph/Hz 380-415/3/50 190.0 184.5 179.0 173.0 168.0 Capacity Cooling kW 161.5 48.47 49.33 47.40 45.71 43.86 Power input kW 42.08 3.92 3.74 3.78 3.78 3.83 EER 3.84 7.38 7.04 7.06 7.06 7.12 ESEER 7.13 213.0 207.0 201.0 194.0 188.0 Capacity 181.0 kW Heating 46.13 51.36 49.53 47.42 45.11 Power input 43.47 kW 4.62 4.03 4.06 4.09 4.17 COP 4.16 Connectable Total capacity 50~130% of outdoor unit capacity Max. quantity indoor unit 64 Compressor Type DC inverter Quantity 6 Type Fan motor DC motor Quantity 6 Type Refrigerant R410A 11×2+16×2 16×3 16×3 13+16×2 Factory charging 13+16×2 13×2+16 kg TCO2eq 22.97×2+33.41×2 33.41×3 33.41×3 27.14+33.41×2 27.14+33.41×2 27.14×2+33.41 ton Liquid pipe Φ25.4 Φ22.2 Φ22.2 Φ22.2 Φ22.2 Φ22.2 mm Pipe mm connections Gas pipe Φ41.3 Φ41.3 Φ41.3 Φ41.3 Φ41.3 Φ44.5 mm Oil balance pipe Φ6.35 48000 46000 48000 48000 48000 56000 m3/h Air flow rate Sound pressure level dB(A) 68 80 Sound power level dB(A) (1340×1635×790)×3 Net dimensions (W×H×D) mm (990×1635×790)×2+(1340×1635×790)×2 (1405×1805×855)×3 Packed dimensions (W×H×D) mm (1055×1805×855)×2+(1405×1805×855)×2 340×3 340×3 305+340×2 297+340×2 305×2+340 Net weight kg 237×2+340×2 Gross weight kg 323×2+358 315+358×2 323+358×2 358×3 358×3 252×2+358×2 Operating temperature range °C Cooling: -5-48; Heating: -20-24 HP Model Combined type Power supply V/Ph/Hz Capacity Cooling kW Power input kW EER ESEER Capacity kW Heating Power input kW COP Connectable Total capacity Max. quantity indoor unit Compressor Type Quantity Type Fan motor Quantity Type Refrigerant Factory charging kg TCO2eq ton Liquid pipe mm Pipe mm connections Gas pipe mm Oil balance pipe m3/h Air flow rate Sound pressure level dB(A) Sound power level dB(A) Net dimensions (W×H×D) mm Packed dimensions (W×H×D) mm Net weight kg Gross weight kg Operating temperature range °C Notes: Capacities are based on the following conditions: Cooling: Indoor temperature 27oC DB/19oC WB; Outdoor temperature 35oC DB/24oC WB; Heating: Indoor temperature 20oC DB/15oC WB; Outdoor temperature 7oC DB/6oC WB. Piping length: Interconnecting piping length is 7.5m, level difference is zero. Connection piping diameter of single-unit is the stop valve diameter of the unit. Connection piping diameter of multi-unit is the main pipe connecting to the first indoor branch joint, is case of the total equivalent liquid length is less than 90m. If the total equivalent liquid length is more than 90m, please refer to technical manual to choose the connection piping diameter. Sound values are measured in a semi-anechoic room, at a position 1m in front of the unit and 1.3m above the floor. Notes: Capacities are based on the following conditions: Cooling: Indoor temperature 27oC DB/19oC WB; Outdoor temperature 35oC DB/24oC WB; Heating: Indoor temperature 20oC DB/15oC WB; Outdoor temperature 7oC DB/6oC WB. Piping length: Interconnecting piping length is 7.5m, level difference is zero. Connection piping diameter of single-unit is the stop valve diameter of the unit. Connection piping diameter of multi-unit is the main pipe connecting to the first indoor branch joint, is case of the total equivalent liquid length is less than 90m. If the total equivalent liquid length is more than 90m, please refer to technical manual to choose the connection piping diameter. Sound values are measured in a semi-anechoic room, at a position 1m in front of the unit and 1.3m above the floor. 17 80 MV5-X2230W/V2GN1 18HP×2+22HP×2 82 MV5-X2295W/V2GN1 16HP+22HP×3 223.0 58.53 3.81 7.10 250.0 60.60 4.13 229.5 60.31 3.81 7.10 257.0 62.23 4.13 13×2+16×2 27.14×2+33.41×2 13+16×3 27.14+33.41×3 64000 62000 305×2+340×2 323×2+358×2 297+340×3 315+358×3 246.0 65.78 3.74 7.04 276.0 68.49 4.03 16×4 33.41×4 64000 340×4 358×4 18