Everest 6000l Vario-therm

   EMBED


Share

Transcript

EVEREST 6000L VARIO-THERM The 6000L Vario-Therm is a revolutionary fully self contained low temperature infrared temperature sensor that is extremely small. The Vario-Therm measures temperatures from -40°C to 100°C with ± 0.5° of accuracy. The TTL/SLR Intra-Optical Light Sighting provides a visible light emitting diode that illuminates the EXACT target AREA being measured. The pattern of the detector in the infrared thermometer is projected on the target, providing a three dimensional reading of the target. The field of view is variable from 2mm to 4 degrees using the new Vario-Zooom focusing feature. The standard output for the Vario-Therm is Analog Milivolt. The digital output is PWM format. The optional outputs are 4-20 mA, 0-5 volts and Type J or Type K Thermocouple. The response time of the instruments is less than 1 second. The instruments dimensions are 22.2mm diameter and 68mm in length. Enabling better global research outcomes in soil, plant & environmental monitoring. www.ictinternational.com : [email protected] : +612 6772 6770 EVEREST 6000L VARIO-THERM Specifications MODEL 6000L TEMPERATURE MEASUREMENT SCALE RANGE: -40°C TO 100°C RESOLUTION: 0.1°C ACCURACY: ±0.5°C REPEATABILITY: ±0.1°C TEMPERATURE: ALL FUNCTIONS IN °C NOISE EFFECTIVE TEMPERATURE: ±0.2°C OPTICAL CONSIDERATIONS OPTICAL CONFIGURATION: ROBUST, AEROSPACE-QUALITY,DOUBLE-COATED ZINC SELENIDE OPTICS PER MILITARY SPECIFICATION MILC-13508 SPECTRAL PASS BAND: 8 < WAVELENGTHS < 14 MICRONS SIGHTING: TTL/SLR INTRA-OPTICAL LIGHT SIGHTING (U.S. PATENT NO. 4,494,881) FOCUS: FIELD FOCUSABLE, CONVERGING OPTICS FROM 2MM TO 4° USING VARIO-ZOOOM™(U.S. PATENT NO. 7,355,187) OPERATING CONDITIONS OPERATING ENVIRONMENT: -10°C TO 70°C, UP TO 99% RELATIVE HUMIDITY, NONCONDENSING STORAGE TEMPERATURE: SAME AS OPERATING ENVIRONMENT TEMPERATURE ELECTRICAL INTERFACE POWER REQUIREMENTS: 5V TO 26V DC (CURRENT DRAW: 1.0); 110 VAC 60Hz OUTPUT SIGNAL: STANDARD: ANALOG: MILIVOLT (10mV/°C) DIGITAL: PWM (PULSE WITH MODULATION) FORMAT OPTIONAL: 4-20 mA; O-5 VOLT AND TYPE J OR TYPE K THERMOCOUPLE GENERAL RESPONSE TIME: .10 SECOND EMISSIVITY COMPENSATION: PRESET TO 0.97 (DEFAULT)/CUSTOMER’S SPECIFICATION OPERATING DISTANCE: 2 CM TO 300 METERS DIMENSIONS: 7/8 INCH DIAMETER BY 2-2/3 INCH LENGTH WARRANTY: ONE-YEAR LIMITED WARRANTY ON PARTS AND LABOR Enabling better global research outcomes in soil, plant & environmental monitoring. www.ictinternational.com : [email protected] : +612 6772 6770 Powered by TCPDF (www.tcpdf.org)