COOPER CROUSE-HINDS ® EVI SERIES EXPLOSIONPROOF FACTORY SEALED INCANDESCENT LUMINAIRES 100-500 WATT MEDIUM AND MOGUL BASE CL. I, DIV. 1, GROUPS C & D • CL I, ZONE 1, GROUP IIB • ENCLOSURE TYPE 4X • MARINE & WET LOCATIONS 2 EVI Series Factory Sealed Incandescent Luminaires EVI301 Series - Medium Base EVI501 Series - Mogul Base Need it fast? ASK FOR LIGHTNING SERVICE™ DELIVERY. We’re ready to ship the EVI luminaires you need in 24 to 48 hours when you ask for Lightning Service™ delivery. Two ordering options are available - components or complete luminaire unit pack (complete luminaire with mounting module in a single carton). Complete luminaires must be made up of the components listed below: Same-day to 24-hour shipping: Components We'll ship these components the same day when the distributor's order requesting same-day Lightning Service is placed with us before 12:00 p.m. Eastern time. If placed after 12:00 p.m. EST, components will ship the next day. Luminaire Body & Globe Assembly with Guard: Medium Base EVI301 Mogul base EVI501 Mounting modules: EVMP2, EVMP3, EV22, EV33, EV87, EVMJ4, EVIJ2 Shipped within 48 hours: Complete Luminaire Unit Pack Complete luminaire with mounting module shipped in a single carton. Maximum line item quantity for Lightning Service delivery - 12. For larger quantities, typically 2-4 weeks. Lightning Service delivery is available for many of our most popular products, and we’re adding more all the time. Visit the Quick Ship area of our web site www.crouse-hinds.com to see the most up-to-date listing of Lightning Service products. Lightning Service products are also designated in the Cooper Crouse-Hinds Catalog 6000 and price list. Also available from Cooper Crouse-Hinds: • VaporGard™ Incandescent Luminaires Class I, Division 2 Groups A, B, C & D • Nonmetallic NDA Corro-gard™ Incandescent Luminaires Class I, Division 2 Groups A, B, C & D Cooper Crouse-Hinds offers a complete line of industrial luminaires including incandescent, HID, fluorescent and induction light sources to fulfill every application need. See Section L of Cooper Crouse-Hinds Catalog 6000 for the complete offering. Copyright© 2003 Cooper Industries, Inc. EVI Series Factory Sealed Incandescent Luminaires EVI301 Series - Medium Base EVI501 Series - Mogul Base • Cl. I, Div 1, Groups C & D • Marine & Wet Locations • Cl. I, Zone 1 & 2, Group IIB • 4X; IP66 • Cl. II, Groups E, F & G (Max 150W - Medium base) • Cl. III & Simultaneous Presence (Max 150W - Medium base) Application: Standard Finishes: EVI series incandescent luminaires are used: • for Type 4X, marine, wet location and hose down environments. • where a consistent light level relatively unaffected by extremes in ambient temperature (-40°C to +65°C) is required. • in areas that require lamps to reach full illumination immediately. • in areas that require lamps to be frequently turned on and off. • indoor & outdoor in locations which are hazardous due to the presence of flammable vapors or gases, ignitible dusts or ignitible fibers & flyings. • where a luminaire is required for tough environmental conditions involving corrosives, water, dust and extreme temperatures. • manufacturing plants, heavy industrial facilities, industrial process facilities such as refineries, chemical, petrochemical, pharmaceutical and platforms. • for lighting of loading docks, tunnels, stairways, storage closets & task lighting. • Copper free aluminum - Corro-free™ epoxy powder coat • Stainless steel - Natural • Krydon® Reflectors - High reflectance white Features: • Ambient suitability to 65ºC. • Standard 90ºC rated building wire for 150W max 40ºC ambient application - represents more than 75% of all applications. • Type 4X, marine outdoor locations. • Factory sealed - no external seals required. • Quick connect - fixture threads onto the mounting module for easy installation. • One size luminaire for all medium base incandescent lamps through 300W. • One size luminaire for all mogul base incandescent lamps through 500W. • Small compact size - ceiling mount is 13¾” long. • Shock absorbing receptacle. • Easy to assemble & relamp. • Silicone gaskets seal out dirt and moisture. • Epoxy powder coat for corrosion resistance. • Same mounting modules as used with the EVM & EVLP series. Standard Materials: • Body, mounting modules and guard - copperfree aluminum • Globe - heat & impact resistant glass • Gaskets - silicone • External hardware - stainless steel • Reflectors - Krydon® fiberglass-reinforced polyester Electrical Ratings: Sources / Wattages • Medium Base - Maximum 300W (PS25) • Mogul Base - Maximum 500W (PS40) Voltages • Medium Base 120V (250V with suffix /250) • Mogul Base 277V Hub Size • ¾” or 1" NPT pendant, ceiling, wall mount • ¾" NPT bulkhead mount Certifications and Compliances: NEC & CEC: • Class I, Division 1, Groups C & D • Class I, Zone 1, Group IIB • Class II, Groups E, F & G • Marine Locations, Wet Locations, Enclosure Type 4X, IP66 • UL Listed • cUL Listed (Certified by UL to CSA Standards) NEC: • Class III; Simultaneous Presence UL Standards: • 844 Electric Fixture Hangers for Hazardous Locations • 1598 Luminaires • 1598A Luminaires for Installation on Marine Vessels CSA Standards: • C22.2 No. 137 Options: Description • 250V luminaire for export applications (medium base only) Suffix to be added to Cat. No. /250 Accessories: • Reflectors - See Ordering by Components on page 5. Copyright© 2003 Cooper Industries, Inc. 3 4 EVI Series Factory Sealed Incandescent Luminaires EVI301 Series - Medium Base EVI501 Series - Mogul Base • Cl. I, Div 1, Groups C & D • Marine & Wet Locations • Cl. I, Zone 1 & 2, Group IIB • 4X; IP66 • Cl. II, Groups E, F & G • Cl. III & Simultaneous Presence EVI301 SERIES EVI501 SERIES Mounting Style Hub Size Medium Base with EV505 Guard (Max. 300W PS25) Mogul Base with EV503 Guard (Max. 500W PS40) Pendant Mount ¾” 1” EVIA2301 EVIA3301 EVIA2501 EVIA3501 Ceiling Mount ¾” 1” EVICX2301 EVICX3301 EVICX2501 EVICX3501 Wall Mount ¾” 1” EVIBX2301 EVIBX3301 EVIBX2501 EVIBX3501 Bulkhead Mount ¾” 1” EVIBH2301 ------ ----------- Stanchion Mount 1¼” EVIJ4301 EVIJ4501 EVI301✔ EVI501✔ Luminaire with Guard Less Mounting Module Note: Medium base luminaires (EVI301 Series) - For A19 lamps up to 100W, use Leviton socket extension catalog number 2005. Mogul base luminaires (EVI501 Series) - For PS30 medium base lamps, use Cooper Wiring Devices socket adapter catalog number 332. ✔ - Available with Lightning Service™ Delivery. See Page 2 for details. Copyright© 2003 Cooper Industries, Inc. EVI Series Factory Sealed Incandescent Luminaires • Ordering by Components EVI301 Series - Medium Base EVI501 Series - Mogul Base EVI Luminaires are available in components. A complete luminaire consists of: I. Mounting Module II. EVI Luminaire Body and Globe Assembly III. Guard, Reflector I. Mounting Module: Type Conduit Cat. No. Pendant ¾” 1” EVMP2✔ EVMP3✔ Ceiling and Wall Box ¾” 1” EV22✔ EV33✔ Wall Bracket Arm ¾” 1” EV22✔ & EV87✔ EV33✔ & EV87✔ Stanchion 1¼” EVMJ4✔ Bulk Head ¾” EVIJ2✔ II. Luminaire Body and Globe Assembly with Guard Type Cat. No. Medium Base EVI301✔ Mogul Base EVI501✔ III. Guards and Reflectors Type Cat. No. Guard - Fits EVI301 Series (medium base) EV505 Guard - Fits EVI501 Series (mogul base) EV503 Dome Reflector - Fits EVI301 Series (medium base) RD636 Angle Reflector - Fits EVI301 Series (medium base) RA636 Dome Reflector - Fits EVI501 Series (mogul base) RD739 Angle Reflector - Fits EVI501 Series (mogul base) RA739 ✔ - Available with Lightning Service™ Delivery. See Page 2 for details. Copyright© 2003 Cooper Industries, Inc. 5 EVI Series Factory Sealed Incandescent Luminaires 6 • Family Tree • Temperature Performance Data EVI301 Series - Medium Base EVI501 Series - Mogul Base Family Tree: STANCHION EVMJ4 1 1/4” HUB✔ CEILING EV22 3/4” HUB✔ EV33 1” HUB✔ PENDANT EVMP2 3/4” HUB✔ EVMP3 1” HUB✔ WALL EV22 & EV87 3/4” HUB✔ EV33 & EV87 1” HUB✔ BULKHEAD EVIJ2 3/4” HUB✔ EVI SERIES HOUSING AND GLOBE ASSEMBLY WITH GUARD MEDIUM BASE EVI301✔ MOGUL BASE EVI501✔ OPTIONAL ANGLE REFLECTOR RA636 EVI301 SERIES RA739 EVI501 SERIES OPTIONAL DOME REFLECTOR RD636 EVI301 SERIES RD739 EVI501 SERIES Temperature Performance Data: Type Watts / Lamp EVI301 Medium Base 100W 150W 200W 300W / A21 or A19* / A21 / A23 or A25 / PS25 EVI501 Mogul Base 200W / PS30* 300W / PS35 500W / PS40 Class I, Div 1 (Class I, Zone 1) Class II Simultaneous Presence Supply Wire Temp (ºC) Ambient Ambient Ambient 40ºC 55ºC 65ºC 40ºC 40ºC 40ºC 55ºC 65ºC T3C T3C T2C T2C T3C T3C --------- T3C T3C --------- 90ºC 90ºC 105ºC 105ºC 105ºC 105ºC 125ºC 125ºC 125ºC 125ºC 125ºC 125ºC T4 T4 T3C T3C T3 T3 T3A --------- T3A --------- 90ºC 90ºC 105ºC 90ºC 90ºC 105ºC 105ºC 125ºC 125ºC T4 T4 T3 T3 T4A T4 T3A T3C T3C T2D T2D Ambient * Note: Medium base luminaires (EVI301 Series) - For A19 lamps up to 100W, use Leviton socket extension catalog number 2005. Mogul base luminaires (EVI501 Series) - For PS30 medium base lamps, use Cooper Wiring Devices socket adapter catalog number 332. ✔ - Available with Lightning Service™ Delivery. See Page 2 for details. Copyright© 2003 Cooper Industries, Inc. EVI Series Factory Sealed Incandescent Luminaires • Medium Base Dimensions and Weights 7 EVI301 Series - Medium Base Medium Base EVI Luminaire Dimensions (Inches): Pendant Mount Ceiling Mount Stanchion Mount 6¾ 4 13¼ /16 4 5 1¼ 12 12¾ 12¾ 13½ 1 13 13¾ 1¼ Conduit 7¼ 25º 7¼ Bulkhead Mount Wall Mount 129/16 97/16 9¼ 6¾ 4 1 15/16 4 4 /32 13 16 /16 13 /16 13 /16 5 161/8 153/8 161/16 Medium Base Net Luminaire Weights (lbs.): EVI301 with guard 11 lbs. Add mounting modules: Pendant Ceiling Wall Bulkhead Stanchion 1.0 2.0 4.5 2.2 2.5 lbs lbs lbs lbs lbs Add for Reflectors RD636 (Dome Reflector, Small) RA636 (Angle Reflector, Small) RD739 (Dome Reflector, Small) RA739 (Angle Reflector, Small) Copyright© 2003 Cooper Industries, Inc. 1.5 1.0 2.0 1.4 lbs lbs lbs lbs 8 EVI Series Factory Sealed Incandescent Luminaires • Mogul Base Dimensions and Weights EVI501 Series - Mogul Base Mogul Base EVI Luminaire Dimensions (Inches): Pendant Mount Ceiling Mount Stanchion Mount 6¾ 4 15 /16 4 5 1¼ 161/8 155/8 17¼ 175/8 1 165/8 18¼ 1¼ Conduit 10 25º 10 Wall Mount 1315/16 97/16 6¾ 4 1 4 215/16 /16 5 1911/16 Mogul Base Net Luminaire Weights (lbs.): EVI501 with guard 24 lbs. Add mounting modules: Pendant Ceiling Wall Bulkhead Stanchion 1.0 2.0 4.5 2.2 2.5 lbs lbs lbs lbs lbs Add for Reflectors RD636 (Dome Reflector, Small) RA636 (Angle Reflector, Small) RD739 (Dome Reflector, Small) RA739 (Angle Reflector, Small) Copyright© 2003 Cooper Industries, Inc. 1.5 1.0 2.0 1.4 lbs lbs lbs lbs EVI Series Factory Sealed Incandescent Luminaires • Photometric Data 9 EVI301 Series - Medium Base EVI501 Series - Mogul Base Medium Base Luminaire with Globe and Guard EVICX2301 Lamp: 300W/PS25 Incandescent CANDELAS CANDLEPOWER DISTRIBUTION (in Candelas) 125 Vertical Angle Front 0 259 5 259 15 326 25 417 35 426 45 434 55 471 65 529 75 555 85 524 90 505 95 487 105 376 115 143 125 22 135 6 145 2 155 0 165 0 175 0 180 1 ZONAL LUMENS Side 259 265 344 386 375 382 411 474 503 475 458 443 351 148 24 6 2 0 1 1 1 With Zone 0-10 10-20 20-30 30-40 40-50 50-60 60-70 70-80 80-90 90-100 100-110 110-120 120-130 130-140 140-150 150-160 160-170 170-180 Lumens 26 94 179 244 311 394 494 552 541 502 378 150 25 4 2 0 0 0 Total 3897 3 SIDE E Note: Photometric data was developed using a 300W incandescent lamp (6,360 lumens). For other lamp wattages, use the following conversion factors (multipliers) with both candlepower distribution and isofootcandle charts. Multipliers do not apply to Coefficients of Utilization. LAMP WATTS 100W 150W 200W COEFFICIENTS OF UTILIZATION Effective Floor Cavity Reflectance 20% ROOM CAVITY RATIO Eff. Ceil. Wall 3 4 7 8 9 10 80* 50* .561 30* .520 10* .483 .466 .408 .360 .395 .331 .281 .344 .279 .230 .301 .265 .236 .202 .188 .157 .235 .174 .132 .212 .153 .113 .191 .135 .098 .173 .120 .085 70* 50* .529 30* .492 10* .459 .438 .387 .343 .372 .314 .267 .324 .265 .219 .283 .250 .224 .191 .179 .149 .222 .165 .125 .200 .146 .108 .180 .128 .093 .164 .114 .081 50* 50* .470 30* .440 10* .413 .387 .345 .308 .327 .279 .240 .286 .236 .197 .250 .220 .200 .171 .161 .134 .196 .148 .112 .177 .130 .097 .160 .115 .083 .146 .102 .073 30* 50* .415 30* .391 10* .370 .340 .305 .276 .286 .247 .214 .250 .209 .176 .218 .193 .177 .151 .144 .120 .172 .131 .100 .155 .115 .086 .141 .102 .074 .129 .091 .064 10* 50* .365 30* .346 10* .329 .296 .269 .244 .248 .216 .189 .217 .183 .155 .189 .168 .155 .133 .127 .105 .149 .114 .088 .135 .101 .076 .123 .089 .065 .112 .080 .056 0* 0* .219 .166 .134 .107 .087 .071 .060 .051 .043 2 D C 250 FRONT 1 A B 0 CONVERSION FACTOR .275 .45 .63 1 .302 2 6 5 *Percent Reflectance ISOFOOTCANDLE CHART: 375 -1 Footcandle Values for Isofootcandle Lines -2 500 -3 -3 -2 -1 0 1 2 3 RATIO OF DISTANCE TO MOUNTING HEIGHT Mtg. Hgt. A B C D E 10' 12' 16' 20' 25' 2.00 1.39 0.78 0.50 0.32 1.00 0.69 0.39 0.25 0.16 0.50 0.35 0.20 0.13 0.08 0.20 0.14 0.08 0.05 0.03 0.10 0.07 0.04 0.03 0.02 Isofootcandle chart shows illuminance in footcandles at ground level. Medium Base Luminaire with Globe and Dome Reflector (Less Guard) EVICX2301 Lamp: 300W/PS25 Incandescent CANDELAS* CANDLEPOWER DISTRIBUTION (in Candelas) Vertical Angle 0 5 15 25 35 45 55 65 75 85 90 95 105 115 125 135 145 155 165 175 180 ZONAL LUMENS Candela 1022 1024 1097 1127 996 880 772 320 141 46 22 39 36 8 3 2 2 2 3 2 3 With Zone 0-10 10-20 20-30 30-40 40-50 50-60 60-70 70-80 80-90 90-100 100-110 110-120 120-130 130-140 140-150 150-160 160-170 170-180 Lumens 98 312 517 624 681 670 329 150 51 41 37 8 3 2 1 1 1 0 Total 3528 3 300 Note: Photometric data was developed using a 300W incandescent lamp (6,360 lumens). For other lamp wattages, use the following conversion factors (multipliers) with both candlepower distribution and isofootcandle charts. Multipliers do not apply to Coefficients of Utilization. COEFFICIENTS OF UTILIZATION Effective Floor Cavity Reflectance 20% ROOM CAVITY RATIO Eff. Ceil. Wall 3 4 7 8 9 10 80* 50* .598 30* .577 10* .557 .533 .498 .470 .473 .431 .398 .424 .378 .343 .378 .337 .330 .289 .295 .254 .300 .251 .217 .271 .223 .190 .244 .197 .166 .221 .176 .146 70* 50* .584 30* .565 10* .547 .521 .490 .463 .463 .425 .394 .415 .373 .340 .371 .331 .326 .286 .293 .252 .294 .248 .216 .266 .221 .189 .240 .195 .165 .218 .174 .145 50* 50* .558 30* .542 10* .527 .499 .473 .450 .445 .412 .385 .400 .363 .334 .358 .320 .318 .279 .288 .249 .284 .243 .213 .257 .216 .187 .232 .192 .163 .211 .171 .144 30* 50* .533 30* .520 10* .508 .478 .457 .438 .427 .400 .376 .385 .353 .328 .345 .309 .311 .273 .284 .246 .275 .238 .211 .249 .212 .185 .225 .188 .162 .205 .168 .142 10* 50* .511 30* .500 10* .491 .459 .442 .426 .412 .388 .368 .371 .344 .322 .333 .299 .304 .267 .280 .242 .266 .233 .208 .241 .208 .183 .218 .185 .160 .198 .165 .141 0* 0* .414 .356 .310 .268 .231 .197 .172 .149 .131 2 1 600 A B 0 C DE F CONVERSION FACTOR LESS GUARD WITH GUARD .275 .247 .45 .405 .63 .567 LAMP WATTS 100W 150W 200W 1 .478 2 5 6 *Percent Reflectance ISOFOOTCANDLE CHART: Footcandle Values for Isofootcandle Lines -1 900 -2 -3 -3 -2 -1 0 1 2 3 RATIO OF DISTANCE TO MOUNTING HEIGHT *For luminaires with guard, use .9 multiplier. Copyright© 2003 Cooper Industries, Inc. Mtg. Hgt. A B C D E F 10' 12' 16' 20' 25' 10.00 6.94 3.91 2.50 1.60 5.00 3.47 1.95 1.25 0.80 2.00 1.39 0.78 0.50 0.32 1.00 0.69 0.39 0.25 0.16 0.50 0.35 0.20 0.13 0.08 0.20 0.14 0.08 0.05 0.03 Isofootcandle chart shows illuminance in footcandles at ground level. 10 EVI Series Factory Sealed Incandescent Luminaires • Photometric Data EVI301 Series - Medium Base EVI501 Series - Mogul Base Medium Base Luminaire with Globe and 30˚ Angle Reflector (Less Guard) EVICX2301 Lamp: 300W/PS25 Incandescent 150˚ 160˚ 170˚ 180˚ 170˚ 160˚ 150˚ 140˚ 130˚ CANDLEPOWER DISTRIBUTION (in Candelas) 140˚ 130˚ 120˚ 110˚ 120˚ 100˚ 110˚ 100˚ 90˚ 90˚ 80˚ 70˚ 80˚ FRONT 60˚ 350 50˚ SIDE Zone 0-10 10-20 20-30 30-40 40-50 50-60 60-70 70-80 80-90 90-100 100-110 110-120 120-130 130-140 140-150 150-160 160-170 170-180 Total 60˚ BACK 1050 30˚ 50˚ 1400 1750 40˚ 20˚ 10˚ 2100 0˚ 10˚ 20˚ Back 891 812 700 573 256 124 33 4 7 15 32 59 83 24 5 5 2 3 2 3 5 Note: Photometric data was developed using a 300W incandescent lamp (6,360 lumens). For other lamp wattages, use the following conversion factors (multipliers) with both candlepower distribution and isofootcandle charts. 30˚ CONVERSION FACTOR LESS GUARD WITH GUARD .275 .247 .45 .405 .63 .567 LAMP WATTS 100W 150W 200W ISOFOOTCANDLE CHART: 3 2 1 A B CDE 0 ZONAL LUMENS 70˚ 700 40˚ CANDELAS* Front Side 891 891 977 895 1264 927 1434 907 1227 835 1207 758 1226 432 1128 197 1040 96 673 29 365 8 221 8 96 8 22 7 0 6 0 5 0 4 3 6 2 5 2 5 5 5 Degrees 0 5 15 25 35 45 55 65 75 85 90 95 105 115 125 135 145 155 165 175 180 F -1 Lumens 86 268 435 501 520 499 432 331 175 86 46 12 4 3 2 2 1 0 3403 -2 -3 -3 -2 -1 0 1 2 3 RATIO OF DISTANCE TO MOUNTING HEIGHT Footcandle Values for Isofootcandle Lines Mtg. Hgt. A B C D E F 10' 12' 16' 20' 25' 10.00 6.94 3.91 2.50 1.60 5.00 3.47 1.95 1.25 0.80 2.00 1.39 0.78 0.50 0.32 1.00 0.69 0.39 0.25 0.16 0.50 0.35 0.20 0.13 0.08 0.20 0.14 0.08 0.05 0.03 Isofootcandle chart shows illuminance in footcandles at ground level. *For luminaires with guard, use .9 multiplier. Mogul Base Luminaire with Globe and Guard EVIA2501 Lamp: 500W/PS40 Incandescent CANDELAS Vertical Angle Front 0 887 5 788 15 923 25 1044 35 850 45 832 55 670 65 627 75 757 85 578 90 472 95 556 105 553 115 58 125 23 135 11 145 3 155 3 165 1 175 1 180 1 275 ZONAL LUMENS Side 887 797 848 937 777 684 650 613 834 681 589 640 630 52 19 10 3 0 0 0 1 With Zone 0-10 10-20 20-30 30-40 40-50 50-60 60-70 70-80 80-90 90-100 100-110 110-120 120-130 130-140 140-150 150-160 160-170 170-180 Lumens 80 257 453 516 598 624 670 797 685 661 629 82 18 8 3 1 0 0 Total 6082 3 550 SIDE A 0 BC D CONVERSION FACTOR .375 .588 COEFFICIENTS OF UTILIZATION Effective Floor Cavity Reflectance 20% ROOM CAVITY RATIO Eff. Ceil. Wall 3 4 7 8 9 10 80* 50* .568 30* .531 10* .499 .480 .428 .384 .413 .354 .308 .364 .304 .258 .321 .286 .261 .227 .217 .185 .255 .198 .158 .231 .176 .138 .209 .156 .120 .190 .140 .106 70* 50* .539 30* .507 10* .477 .455 .408 .369 .392 .339 .296 .346 .291 .248 .306 .272 .250 .218 .209 .178 .243 .190 .152 .220 .169 .133 .199 .150 .116 .182 .134 .103 50* 50* .486 30* .460 10* .436 .410 .371 .338 .353 .308 .272 .312 .266 .229 .276 .246 .229 .200 .193 .165 .220 .175 .141 .200 .156 .124 .182 .138 .108 .166 .124 .096 30* 50* .438 30* .417 10* .397 .367 .336 .309 .316 .280 .250 .280 .242 .211 .249 .222 .209 .183 .178 .153 .199 .160 .131 .181 .143 .115 .165 .127 .100 .151 .114 .089 10* 50* .393 30* .376 10* .361 .328 .304 .282 .282 .253 .228 .251 .220 .193 .223 .200 .190 .166 .164 .140 .179 .146 .120 .164 .130 .106 .149 .116 .092 .137 .105 .082 0* 0* .259 .207 .174 .146 .124 .105 .092 .079 .069 2 1 1 .337 2 5 6 *Percent Reflectance ISOFOOTCANDLE CHART: Footcandle Values for Isofootcandle Lines -1 -2 -3 -3 1100 LAMP WATTS 200W 300W E FRONT 825 Note: Photometric data was developed using a 500W incandescent lamp (9,900 lumens). For other lamp wattages, use the following conversion factors (multipliers) with both candlepower distribution and isofootcandle charts. Multipliers are not used with Coefficients of Utilization table. -2 -1 0 1 2 3 RATIO OF DISTANCE TO MOUNTING HEIGHT Copyright© 2003 Cooper Industries, Inc. Mtg. Hgt. A B C D E 10' 12' 16' 20' 25' 5.00 3.47 1.95 1.25 0.80 2.00 1.39 0.78 0.50 0.32 1.00 0.69 0.39 0.25 0.16 0.50 0.35 0.20 0.13 0.08 0.20 0.14 0.08 0.05 0.03 Isofootcandle chart shows illuminance in footcandles at ground level. EVI Series Factory Sealed Incandescent Luminaires • Photometric Data 11 EVI301 Series - Medium Base EVI501 Series - Mogul Base Mogul Base Luminaire with Globe and Dome Reflector (Less Guard) EVIA2500 Lamp: 500W/PS40 Incandescent CANDELAS* Vertical Angle 0 5 15 25 35 45 55 65 75 85 90 95 105 115 125 135 145 155 165 175 180 525 ZONAL LUMENS Candela 2017 1923 1786 1947 1497 1298 1092 841 177 52 7 6 73 6 5 4 3 3 3 2 3 With Zone 0-10 10-20 20-30 30-40 40-50 50-60 60-70 70-80 80-90 90-100 100-110 110-120 120-130 130-140 140-150 150-160 160-170 170-180 Lumens 182 516 876 934 998 978 762 195 57 8 52 7 5 3 2 1 1 0 Total 5578 3 1050 Note: Photometric data was developed using a 500W incandescent lamp (9,900 lumens). For other lamp wattages, use the following conversion factors (multipliers) with both candlepower distribution and isofootcandle charts. Multipliers are not used with Coefficients of Utilization table. COEFFICIENTS OF UTILIZATION Effective Floor Cavity Reflectance 20% ROOM CAVITY RATIO Eff. Ceil. Wall 3 4 7 8 9 10 80* 50* .595 30* .574 10* .555 .530 .496 .468 .470 .429 .396 .420 .375 .340 .374 .335 .327 .287 .292 .253 .300 .252 .218 .272 .225 .193 .246 .200 .169 .225 .180 .151 70* 50* .582 30* .563 10* .546 .519 .488 .461 .461 .423 .392 .413 .370 .338 .368 .329 .323 .284 .290 .251 .295 .249 .217 .268 .223 .192 .242 .199 .169 .221 .179 .150 50* 50* .557 30* .541 10* .527 .498 .472 .450 .443 .411 .384 .398 .361 .332 .355 .319 .316 .278 .286 .248 .285 .244 .215 .260 .219 .190 .235 .195 .167 .215 .176 .149 30* 50* .534 30* .521 10* .510 .479 .457 .439 .427 .400 .376 .384 .353 .327 .344 .309 .309 .273 .282 .246 .277 .240 .213 .252 .215 .188 .229 .192 .166 .209 .174 .148 10* 50* .513 30* .503 10* .493 .461 .443 .428 .412 .389 .369 .371 .344 .322 .333 .299 .303 .268 .279 .243 .268 .236 .211 .245 .212 .187 .223 .189 .165 .204 .171 .147 0* 0* .416 .357 .310 .267 .232 .200 .176 .155 .137 2 1 BC D E F 0 CONVERSION FACTOR LESS GUARD WITH GUARD .375 .338 .588 .529 LAMP WATTS 200W 300W 1 .482 2 5 6 *Percent Reflectance ISOFOOTCANDLE CHART: 1575 Footcandle Values for Isofootcandle Lines -1 -2 -3 -3 -2 -1 0 1 2 3 RATIO OF DISTANCE TO MOUNTING HEIGHT Mtg. Hgt. A B C D E F 10' 12' 16' 20' 25' 20.00 13.89 7.81 5.00 3.20 10.00 6.94 3.91 2.50 1.60 5.00 3.47 1.95 1.25 0.80 2.00 1.39 0.78 0.50 0.32 1.00 0.69 0.39 0.25 0.16 0.50 0.35 0.20 0.13 0.08 Isofootcandle chart shows illuminance in footcandles at ground level. *For luminaires with guard, use .9 multiplier. Mogul Base Luminaire with Globe and Angle Reflector (Less Guard) EVIA2500 Lamp: 500W/PS40 Incandescent 140º 150º 160º 170º 180º 170º 160º 150º 140º 130º 130º 120º 120º 110º 110º 100º 100º 90º 90º 80º 80º 70º 70º 525 60º 60º 50º 40º 1050 50º 1575 40º 2100 30º 30º 20º 10º 2625 0º 10º 20º Vertical Angle 0 5 15 25 35 45 55 65 75 85 90 95 105 115 125 135 145 155 165 175 180 CANDELAS* Front Side 1938 1938 1904 1829 1967 1721 1858 1754 1671 1424 1564 1270 1477 1027 1153 524 1285 138 870 34 750 5 328 6 139 7 35 7 0 7 0 7 1 7 0 6 2 6 2 5 5 5 Back 1938 1783 1601 1391 1030 229 44 3 3 7 7 7 114 8 7 4 4 3 3 2 5 ZONAL LUMENS With Zone 0-10 10-20 20-30 30-40 40-50 50-60 60-70 70-80 80-90 90-100 100-110 110-120 120-130 130-140 140-150 150-160 160-170 170-180 Total Lumens 175 496 772 860 859 728 593 497 288 100 56 11 5 4 3 2 1 0 5452 *For luminaires with guard, use .9 multiplier. Copyright© 2003 Cooper Industries, Inc. Note: Photometric data was developed using a 500W incandescent lamp (9,900 lumens). For other lamp wattages, use the following conversion factors (multipliers) with both candlepower distribution and isofootcandle charts. CONVERSION FACTOR LESS GUARD WITH GUARD .375 .338 .588 .529 LAMP WATTS 200W 300W 3 2 1 A B 0 C DE F -1 -2 -3 -3 -2 -1 0 1 2 3 RATIO OF DISTANCE TO MOUNTING HEIGHT ISOFOOTCANDLE CHART: Footcandle Values for Isofootcandle Lines Mtg. Hgt. A B C D E F 10' 12' 16' 20' 25' 10.00 6.94 3.91 2.50 1.60 5.00 3.47 1.95 1.25 0.80 2.00 1.39 0.78 0.50 0.32 1.00 0.69 0.39 0.25 0.16 0.50 0.35 0.20 0.13 0.08 0.20 0.14 0.08 0.05 0.03 Isofootcandle chart shows illuminance in footcandles at ground level. C O O P E R C ROU S E - H I N DS® EVI SERIES EXPLOSIONPROOF FACTORY SEALED INCANDESCENT LUMINAIRES 100-500 WATT MEDIUM AND MOGUL BASE Distributed by: For more information: If further assistance is required, please contact an authorized Cooper Crouse-Hinds Distributor, Sales Office or Customer Service Department: In the U.S.: In Australia: Cooper Crouse-Hinds P.O. Box 4999 Syracuse, NY 13221 (315) 477-5531 FAX: (315) 477-5179 Cooper Electrical Australia 61-29-743-7000 FAX: 61-29-743-7069 [email protected] [email protected] In Asia (Singapore): In Canada: Cooper Crouse-Hinds Canada (905) 507-4187 FAX: (905) 568-7048 CEAG Crouse-Hinds Asia Pacific Pte. Ltd. 65-6297-4849 FAX: 65-6297-4819 [email protected] In Middle East (Dubai): In Mexico: Crouse-Hinds Domex, S.A. de C.V. 52-555-804-4000 FAX: 52-555-804-4078 CEAG Middle East LLC 971-4-324-1519 FAX: 971-4-324-1640 In India: In Latin America/Caribbean: Cooper Crouse-Hinds (954) 764-3853 FAX: (954) 764-3854 In Europe (Germany): CEAG Sicherheitsstechnik GmbH 49-6271-81524 FAX: 49-6271-81329 CEAG Flameproof Control Gears Private Ltd. 91-22-2493-1854 FAX: 91-22-2496-0313 For the latest in new products & services, visit our website at: www.crouse-hinds.com Solutions.Worldwide. TM 4824-0803 Crouse-Hinds is a registered trademark of Cooper Industries, Inc. © 2003 Cooper Industries, Inc. Printed in U.S.A.