Evolution NZ
FRE E-S TAND I NG PE LLE T S TOVE
TECHNICAL MANUAL
PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS PELLET BURNING ROOM HEATER. FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE, BODILY INJURY OR EVEN DEATH Contact your building or fire officials about restrictions and installation inspection requirements in your area.
50-1750
Table of Contents Safety Warnings & Recommendations...............................................................................................3 Installation.....................................................................................................................................6 Rating Label Location................................................................................................................6 Deciding Where to Locate your Pellet Appliance..........................................................................6 Removing Pellet Stove From Pallet.............................................................................................6 Dimensions..............................................................................................................................7 Clearances to Combustibles.......................................................................................................8 Alcove Clearances.....................................................................................................................8 Hearth Pad Pedestal Installation.................................................................................................9 Vent Termination Requirements................................................................................................10 Outside Fresh-Air Connection...................................................................................................11 Exhaust And Fresh Air Intake Locations....................................................................................11 Mobile Home Installation.........................................................................................................12 Corner Through Wall Installation..............................................................................................12 Horizontal Exhaust Through Wall Installation.............................................................................13 Through Wall With Vertical Rise and Horizontal Termination Installation- Recommended..............14 Through Concrete Wall With Vertical Rise Installations...............................................................14 Inside Vertical Installations......................................................................................................15 Outside Vertical Installations....................................................................................................15 Hearth Mount Installation........................................................................................................16 Exterior Mounted Exhaust Blower.............................................................................................17 Typical Through Wall With Exterior Blower Kit Installation - Horizontal Termination......................18 Typical Through Wall With Exterior Blower Kit Installation - Vertical Termination..........................19 Thermostat Installation............................................................................................................20 Optional Slider/Damper Installation..........................................................................................20 Slider/Damper Set-Up..............................................................................................................21 Troubleshooting............................................................................................................................22 Wiring Diagram.............................................................................................................................25 Parts List......................................................................................................................................26 Parts Diagram - Components..........................................................................................................28 Parts Diagram - Steel.....................................................................................................................29 Installation Data Sheet..................................................................................................................30
2
Safety Warnings & Recommendations * This manual is designed for the technician in conjunction with the owner’s manual. * Please read this entire Installation Manual before installing or operating your ENVIRO Pellet Stove. Failure to follow these instructions may result in property damage, bodily injury or even death. Any unauthorized modification of the appliance or use of replacement parts not recommended by the manufacturer is prohibited. All national and local regulations and European Standards shall be complied with when installing this appliance. Caution: Do not connect to any air distribution duct or system. Warning: Parts of the appliance, especially the external surfaces, will be hot to touch when in operation so use due care and the fire gloves provided. Never place wood, paper, furniture, drapes or other combustible materials within 80cm (31½”) of the front of the unit, 20cm (7⅞”) from each side, and 10cm (4”) from the back of the unit. Do not let children or pets touch it when it is hot. To prevent the possibility of a fire, ensure that the appliance is properly installed by adhering to the installation instructions. An ENVIRO dealer will be happy to assist you in obtaining information with regards to your local building codes and installation restrictions. FIRE EXTINGUISHER AND SMOKE DETECTION: All homes with a pellet burning stove should have at least one fire extinguisher in a central location known to all in the household. Smoke detectors should be installed and maintained in the room containing the stove when installing and operating a pellet burning appliance. If it sounds the alarm, correct the cause but do not deactivate. You may choose to relocate the smoke detection devise within the room; DO NOT REMOVE THE SMOKE DETECTOR FROM THE ROOM. CHIMNEY OR RUN AWAY FIRE: Call local fire department. Close the draft fully. Extinguish the fire in the burn pot liner with a cup of water and close the door. Examine the flue pipes, chimney, attic, and roof of the house, to see if any part has become hot enough to catch fire. If necessary, spray with fire extinguisher or water from the garden hose. IMPORTANT: Do not operate the stove again until you are certain the chimney and its lining have not been damaged. FUEL: This pellet stove is designed and approved to only burn wood pellet fuel with up to 3% ash content. Dirty fuel will adversely affect the operation and performance of the unit and may void the warranty. Check with your dealer for fuel recommendations. THE USE OF CORDWOOD IS PROHIBITED BY LAW. When filling fuel hopper, open lid on top of unit, check hopper for foreign objects, empty the bag into the hopper, DO NOT OVER FILL, and ensure hopper lid closes completely. DO NOT use this appliance as an incinerator. DO NOT use unsuitable and non recommended fuels, including liquid fuels. KEEP ASH PAN FREE OF RAW FUEL. DO NOT PLACE UNBURNED OR NEW PELLET FUEL IN ASH PAN. A fire in the ash pan may occur. SOOT: Operation of the stove with insufficient combustion air will result in the formation of soot which will collect on the glass, the heat exchanger, the exhaust vent system, and may stain the outside of the house. This is a dangerous situation and is inefficient. Frequently check your stove and adjust the slider/ damper as needed to ensure proper combustion. See: “Slider/Damper Setting”.
3
Safety Warnings & Recommendations CLEANING: There will be some build up of fly ash and small amounts of creosote in the exhaust. This will vary due to the ash content of the fuel used and the operation of the stove. It is advisable to inspect and clean the exhaust vent semi-annually or every two tons of pellets. The appliance, flue gas connector and the chimney flue require regular cleaning. Check them for blockage prior to re-lighting after a prolonged shut down period. ASHES: Disposed ashes should be placed in a metal container with a tight fitting lid. The closed container of ashes should be on a non-combustible surface, well away from all combustible materials pending final disposal. If the ashes are disposed of by burial in soil or otherwise locally dispensed, they should be retained in the closed container until all cinders have been thoroughly cooled. IMPORTANT: The door and ash drawer cover must be kept closed except during ignition, refueling and removal of residue material to prevent fume spillage. GLASS: Do not abuse the glass by striking or slamming the door. Do not attempt to operate the stove with broken glass. The stove uses ceramic glass. Replacement glass must be purchased from an ENVIRO dealer. Do not attempt to open the door and clean the glass while the unit is in operation or if glass is hot. To clean the glass, use a soft cotton cloth and mild window cleaner, gas or wood stove glass cleaner, or take a damp paper towel and dip into the fly ash. This is a very mild abrasive and will not damage the glass. ELECTRICAL: The use of a surge protected power bar is recommended. The unit must be grounded. The grounded electrical cord should be connected to a standard 220-240 volts (2.0-2.3 Amps), 50 hertz electrical outlet and also must be accessible. If this power cord should become damaged, a replacement power cord must be purchased from the manufacturer or a qualified ENVIRO dealer. Be careful that the electrical cord is not trapped under the appliance and that it is clear of any hot surfaces or sharp edges. This unit’s maximum power requirement is 525 watts. OPERATION: The door and ash drawer cover must be kept closed securely when the unit is in operation to prevent fume spillage and for proper and safe operation of the pellet stove. Also ensure all gaskets on the door are checked and replaced when necessary. CAUTION: When operating during adverse weather, if the unit exhibits dramatic changes in combustion stop using the unit immediately. INSTALLATION: Contact your local building or fire official to obtain a permit and any information on installation restrictions and inspection requirements for your area. All local regulations, including those referring to national and European Standards need to be complied with when installing this appliance. Be sure to maintain the structural integrity of your home when passing a vent through walls, ceilings, or roofs. It is recommended that the unit be secured into its position in order to avoid any displacement. This appliance must be installed on a floor with an adequate load bearing capacity. If an existing construction doesn’t meet these prerequisite, suitable measures (e.g. load distributing plate) shall be taken to achieve it. DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT. DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
4
Safety Warnings & Recommendations FRESH AIR: Outside Fresh Air connection is optional. Fresh Air must be connected to all units installed in “Air Tight Homes” or where required by local codes. Consider all large air moving devices when installing your unit and provide room air accordingly. NOTE: Extractor fans when operating in the same room or space as the appliance, may cause problems. Limited air for combustion may result in poor performance, smoking and other side effects of poor combustion. The stove’s exhaust system works with negative combustion chamber pressure and a slightly positive chimney pressure. It is very important to ensure that the exhaust system be sealed and airtight. The ash pan and viewing door must be locked securely for proper and safe operation of the pellet stove. Do not burn with insufficient combustion air. A periodic check is recommended to ensure proper combustion air is admitted to the combustion chamber. Setting the proper combustion air is achieved by adjusting the slider damper located on the left side of the stove. Minor soot or creosote may accumulate when the stove is operated under incorrect conditions such as an extremely rich burn (black tipped, lazy orange flames). If you have any questions with regards to your stove or the above-mentioned information, please feel free to contact your local dealer for further clarification and comments. SINCE SHERWOOD INDUSTRIES LTD. HAS NO CONTROL OVER THE INSTALLATION OF YOUR STOVE, SHERWOOD INDUSTRIES LTD. GRANTS NO WARRANTY IMPLIED OR STATED FOR THE INSTALLATION OR MAINTENANCE OF YOUR STOVE. THEREFORE, SHERWOOD INDUSTRIES LTD. ASSUMES NO RESPONSIBILITY FOR ANY CONSEQUENTIAL DAMAGE(S).
SAVE THIS INSTRUCTION MANUAL FOR FUTURE REFERENCE
5
Specifications Dimensions:
Unit Dimensions Height: 871 mm (34 5/16”) Width: 565 mm (22 ¼”) Depth: 595 mm (23 7/16”) 28" (711 mm)
Hearth Pad: Width: 619 mm (24 ⅜”) Depth: 670 mm (26 ⅜”)
24 3/8" (619 mm) 22 1/4" (565 mm)
23 7/16" (595 mm)
5 5/8" (144 mm)
34 5/16" (871 mm)
26 3/8" (670 mm) Figure 1: Dimensions of Evolution.
IMPORTANT: When not installing the optional Hearth Pad on the unit, the minimum requirements for protection on combustibles floors are a width of 620mm (24⅜”) & depth of 670mm (26⅜”) under the unit. 6
2.0 - 2.3 Amps Unit with Full Hopper ~ 140kg (310lb) Mean Flue Gas Temperature - Medium 162°C (324°F) Fuel Consumption - Medium 1.5 kg/hr (3.31 lb/hr)* Heat/Power Output - Medium 6.3 kW (21516 BTU/hr) Average Emissions Rate 19 mg/MJ Fuel type
wood pellets - 6mm dia. - complying with draft standard AS/NZS 4014.6
220 - 240 V
Maximum Power Requirement
525W (1793 BTU/hr)
Mean Flue Gas Temperature - High
188°C (370°F)
Fuel Consumption - High
2.3 kg/hr (5.07 lb/hr)*
Heat/Power Output - High
9.7 kW (33127 BTU/hr)
Average Particular Emissions (dry weight)
0.3 g/kg
Gross Calorific value of Pellets (dry weight)
20.1 MJ/kg (8.64 BTU/lb)
*Note: Consumption will vary with the type of fuel used.
Current
Voltage
80%
Average Efficiency
3.9 kW (13319 BTU/hr)
Heat/Power Output - Low
0.9 kg/hr (1.98 lb/hr)*
Fuel Consumption - Low
121°C (250°F)
Mean Flue Gas Temperature - Low
~ 40kg (90lb)
Hopper Capacity
50 Hz
Frequency
Residential Wood Pellet Heater
AS/NZS 4012:1999, 4013:1999
Class I IP-20
Description
Testing Standard
Classification
Table 1: Evolution Specifications.
Specifications
Rating Label Location:
The rating label is located on the inside of the ash pan cover.
Specifications:
7
Installation Deciding Where to Locate your Pellet Appliance: 1. Do not install the stove in a bedroom or room where people sleep in. 2. Locate the stove in a large and open room that is centrally located in the house. This will optimize heat circulation. 3. Check clearances to combustibles and for the least amount of interference to house framing, plumbing, wiring, et. 4. You can vent the stove with approved pipe through an exterior wall behind the unit or pass it through the ceiling and roof. The stove can connect to an existing masonry or metal chimney (must be lined if the chimney is over 6” (15 cm) diameter, or over 28 inches² (180 cm²) cross sectional area). 5. This unit must not be installed directly onto carpet. If it is to be installed on a carpeted area, a solid surface (wood, metal or approved hearth pad) must be installed between the unit and the carpet. 6. This unit uses large quantities of air for combustion; outside Fresh Air connection is strongly recommended. Fresh Air must be connected to all units installed in Mobile and “Air Tight Homes” (R2000) or where required by local codes. 7. Do not obtain combustion air from an attic, garage or any unventilated space. Combustion air may be obtained from a ventilated crawlspace. 8. The power cord is 8 feet (2.43 m) long and may require a grounded extension cord to reach the nearest electrical outlet.
Removing Pellet Stove From Pallet:
Remove the two (2) wood screws (one on either side of the unit) to remove the unit from the pallet.
1. Remove the right and left hand cabinet sides by loosening the three (3) T-20 Torx screws on the back of the each panel. 2. Remove the one (1) screw located on the front of the cabinet side, behind the top louvers and one (1) screw behind the ash door. 3. Remove the two (2) wood screws that are holding the bottom of the stove to the pallet. 4. Close the side panels.
Figure 1: Screws to take out to remove stove from pallet.
8
Installation Clearances to Combustibles: This unit can be installed on a combustible floor when installed with the optional hearth pad part EF5-103 (for example linoleum, hardwood flooring). If this unit is to be installed onto a carpeted surface, a hearth pad must be used for stability. Back Wall
4" (10cm) l al W nt ce ja Ad
Side Wall
4" (10cm)
77/8" (20cm)
These dimensions are minimum clearances but it is recommended that you ensure sufficient room for servicing, routine cleaning and maintenance. Side wall to unit Back wall to unit Corner to unit In Front of unit
200mm (8 inches) 100mm (4 inches) 100mm (4 inches) 800mm (31½” inches)
Figure 3: Evolution Clearance to Combustibles.
Alcove Clearances: 48" (122cm)
This unit may be installed in an alcove. Maintain these clearances to combustibles.
Minimum Alcove width 1220mm (48 inches) Minimum Alcove height 1220mm (48 inches) Maximum Alcove depth 1220mm (48 inches)
48" (122cm)
Install vent at clearances specified by the vent manufacturer. 48" (122cm)
Figure 4: Evolution Minimum Alcove Size.
9
Installation Hearth Pad Pedestal Installation: This unit can be installed on a combustible floor (e.g. linoleum, hardwood flooring) when the Optional Hearth Pad is installed. If this unit is to be installed onto a carpeted surface, a solid pad must be used underneath the Optional Hearth Pad for stability. Carefully place the the pellet appliance on its back, on the pallet (allow the exhaust tube to fit thru an opening in the pallet). Align the holes in the hearth pad and the unit and install the four (4) screws provided. Stand the unit back up. Adjust the leveling legs to below the Hearth Pad, to support the weight of the unit. When moving the unit - be careful not to damage the floor or the Hearth Pad.
Leveling Legs x4
Figure 5: Installing Hearth Pad Pedestal onto Evolution.
SEISMIC RESTRAINT: All installation scenarios for the Enviro Evolution EF5 require the use of hold-down anchors (one on each side) Fixing to Concrete Floor: Minimum M8 expansion anchors (M10 recommended) or min M8 epoxy- set anchors. Approved Anchors: Expansion Anchors-Ramset Dynabolt and Trubolt, Hilti HAS. Epoxy-set Anchors – Ramset Epcon, Ramset Chemset and Hilti HVU. Fixing to Timber Floor Framing: Minimum 14g x 60 screws (6.3mm diameter) or M10 X 90 coach-screws. These shall be fixed a minimum of 40mm into the centre-line of the existing floor joists. If screws cannot be installed directly into an existing floor joist, solid blocking between joists (min size 90x45) shall be provided. 10
Installation Vent Termination Requirements: IT IS RECOMMENDED THAT YOUR PELLET STOVE BE INSTALLED BY AN AUTHORIZED DEALER/INSTALLER. Table 2: Use in conjunction with Figure 6 for allowable exterior vent termination locations. Letter
Minimum Clearance
A
61cm (24 in)
B
Description Above grass, top of plants, wood, or any other combustible materials.
122 cm (48 in)
Beside/below any door or window that may be opened. (46 cm (18”) if outside fresh air install.)
30 cm (12 in)
Above any door or window that may be opened. (23 cm (9”) if outside fresh air install.)
61cm (24 in)
To any adjacent building, fences and protruding parts of the structure.
E
61cm (24 in)
Below any eave or roof overhang
F
30 cm (12 in)
To outside corner.
G
30 cm (12 in)
To inside corner, combustible wall (vertical and horizontal terminations).
H
91 cm (3 ft) within a height of 4.5 m (15 ft) above the meter/regulator assembly
I
91 cm (3 ft)
C D
J
To each side of center line extended above natural gas or propane meter/ regulator assembly or mechanical vent. From any forced air intake of other appliance
30 cm (12 in)
Clearance to non-mechanical air supply inlet to building, or the combustion air inlet to any appliance.
K
61cm (24 in)
Clearance above roof line for vertical terminations.
L
2.13 m (7 ft)
Clearance above paved sidewalk or paved driveway located on public property.
1. Do not terminate the vent in any enclosed or semi-enclosed areas such as a carport, garage, attic, crawlspace, narrow walkway, closely fenced area, under a sundeck or porch, or any location that can build up a concentration of fumes such as stairwells, covered breezeway, etc.
G
K E D
F
B
Opens
G
Opens
B
A Termination Cap Air Supply Inlet
G
C
I
G Gas Meter
Opens
Restriction Zone
L
H
(Termination not allowed)
Figure 6: Use in conjunction with Table 2 for allowable exterior vent termination
locations. 2. Vent surfaces can become hot enough to cause burns if touched by children. Non-combustible shielding or guards may be required.
3. Termination must exhaust above the inlet elevation. It is recommended that at least five feet of vertical pipe be installed outside when the appliance is vented directly through a wall, to create some natural draft to prevent the possibility of smoke or odor during appliance shut down or power failure. This will keep exhaust from causing a nuisance or hazard from exposing people or shrubs to high temperatures. In any case, the safest and preferred venting method is to extend the vent through the roof vertically. 4. Distance from the bottom of the termination and grade is 30 cm (12 in) minimum. This is conditional upon the plants and nature of grade surface. The exhaust gases are hot enough to ignite grass, plants and shrubs located in the vicinity of termination. The grade surface must not be lawn. 5. If the unit is incorrectly vented or the air to fuel mixture is out of balance, a slight discoloration of the exterior of the house might occur. Since these factors are beyond the control of Sherwood Industries Ltd, we grant no guarantee against such incidents. NOTE: Venting terminals shall not be recessed into walls or siding. 11
Installation Outside Fresh-Air Connection: This Heater must have adequate air for proper combustion in the room that it is installed. A Fresh-air intake is strongly recommended for all installations. Failure to install intake air may result in improper combustion as well as the unit smoking during power failures.
Outside Wall
The inlet to the intake must be below and a minimum of 305mm (12”) away from the unit exhaust outlet. Outside fresh air is mandatory when installing this unit in airtight homes and mobile homes. When connecting to an outside fresh air source, do not use plastic or combustible pipe. A 50mm minimum (2”) ID (inside diameter) steel, aluminum or copper pipe should be used. It is recommended, when you are installing a fresh air system, to keep the number of bends in the pipe to a minimum.
2" ID (51 mm)
Optional Elbow
Figure 7: Outside Air Connection.
Exhaust And Fresh Air Intake Locations: The Exhaust Starter Tube can be installed 2 ways: Angled towards the center - Use a Tee with vertical for a “centered” vertical installation. Straight out the back - For horizontal thru the wall and up installation EXHAUST Location: Base of unit to center of flue Center of unit to center of flue FRESH AIR INTAKE. Base of unit to center of intake Center of unit to center of intake
278mm (1015/16”) 35mm (1⅜”) 227mm (815/16”) 105mm (4⅛”)
10 15/16" (278 mm)
8 15/16" (227 mm)
4 1/8" (105 mm)
1 3/8" (35 mm)
Figure 8: Evolution Inlet and Outlet Location.
IMPORTANT: This unit must be connectect to an 75mm stainless steel vent pipe exhausting outside the building. 12
Installation Mobile Home Installation:
● Secure the heater to the floor using the two holes in the pedestal. ● Ensure the unit is electrically grounded to the chassis of your home (permanently). ● Do not install in a room people sleep in. ● Outside fresh air is mandatory. Secure outside air connections directly to fresh air intake pipe and secure with three (3) screws evenly spaced. CAUTION: THE STRUCTURAL INTEGRITY OF THE MANUFACTURED HOME FLOOR, WALL AND CEILING/ROOF MUST BE MAINTAINED.
ENVIRO EF5
Optional Hearth Pad Flooring Steel Frame 1/4” Lag Bolts Securely Fastened
Ground Wire Directly to Metal Chassis
Figure 9: Mobile home installation.
Corner Through Wall Installation:
Fresh Air Intake 4" (10 cm) Wall thimble manufactured by pellet vent manufacturer.
4" (10 cm)
Figure 10: Corner Installation.
13
Installation Horizontal Exhaust Through Wall Installation: Vent installation: install vent at clearances specified by the vent manufacturer. A chimney connector shall not pass through an attic or roof space, closet or similar concealed spaces, or a floor, or ceiling. Where passage through a wall or partition of combustible construction is desired, the installation must conform with all local regulations, including those referring to regional, national or European Standards. Use 75mm stainless steel vent pipe to exhaust the unit to the outside. 1. Choose a location for your stove that meets the requirements stated in this manual and allows installation with the least amount of interference to house framing, plumbing, wiring, etc. 2. Install a non-combustible hearth pad (where necessary). 3. Place the appliance 375 mm (15”) away from the wall. If the stove is to be set on a hearth pad, set the unit on it. 4. Locate the center of the exhaust pipe on the stove. Extend that line to the wall. Once you have located the center point on the wall, refer to pellet vent manufacturer installation instructions for correct hole size and clearance to combustibles. 5. Install the wall thimble as per the instructions written on the thimble. Maintain an effective vapour barrier in accordance with local building codes. 6. Install a length of 80mm (3”) vent pipe into the wall thimble. The pipe should install easily into the thimble. 7. Install the fresh air intake (see Outside Fresh Air Connection). 8. Connect the exhaust vent pipe to the exhaust pipe on the stove. Seal the connection with high temperature silicone. 9. Push the stove straight back, leaving a minimum of 100mm (4”) clearance from the back of the stove to the wall. Seal the vent pipe to the thimble with high temperature silicone. 10. The pipe must extend at least 30 cm (12”) away from the building. If necessary, bring another length of pipe to the outside of the home to connect to the first section. Do not forget to place high temperature silicone around the pipe that passes through the thimble. 11. Install a vertical pipe, or if all requirements for direct venting are met, install vent termination. The stainless steel cap termination manufactured by the vent manufacturer is recommended. However, when the vent terminates several feet above ground level and there are no trees, plants, etc. within several feet, a 45° elbow can be used as termination. The elbow must be Wall Framing turned down to prevent rain from entering. NOTE: • It is recommended that horizontal through wall installations have 3 to 5 feet (91 to 152 cm) of vertical pipe in the system to help naturally draft the unit in the event of extreme weather or a power outage. • Some horizontal through wall installations may require a “T” and 3 to 5 feet (91 to 152 cm) of vertical pipe outside the building to help draft the unit. This may be required if a proper burn cannot be maintained, after the stove has been tested and the airflow set. This is due to the back pressure in the exhaust caused by airflow around the structure. 14
Interior Wall Surface
Termination Cap Wall Thimble Vent Pipe EF 5
Figure 11: Straight through wall Installation.
Installation • Follow vent manufacturer’s guidelines for installation of venting. High temperature sealant must be used when connecting the vent pipe to the unit’s starter pipe. Improper seals at the vent joints may cause combustion byproducts to leak into the room where installed - seal as required.
Through Wall With Vertical Rise and Horizontal Termination Installation- Recommended:
A 45° down elbow with a screen may be used in place of the termination cap (or stainless steel termination hood).
Figure 12: Venting horizontally with rise.
Through Concrete Wall With Vertical Rise Installations: Horizontal frame for thimble
A 45° down elbow with a screen may be used in place of the termination cap (or stainless steel termination hood). Installation to use if there is a concrete or retaining wall in line with exhaust vent on pellet stove.
Termination cap
Wall thimble 90o elbow Wall framing Vertical section of vent pipe
The termination must be 305mm (12”) from the outside wall and 305mm (12”) above the ground.
Concrete Wall
EF 5
Clean out tee
Figure 13: Venting with concrete wall behind unit .
15
Installation Inside Vertical Installations: 1. Choose a stove location that is ideal. See the section “Deciding Where
to
Locate
your
Pellet Appliance.”
2. Place a non-combustible hearth pad where necessary. 3. Place the unit on the hearth pad (if installed on a carpeted surface) and space the unit in a manner so when the pellet vent is installed vertically, it will be 100mm (4”) away from a combustible wall. 4. Locate the center of the fresh air intake pipe on the unit. Match that center with the same point on the wall and cut a hole about 40mm (1⅝”) in diameter.
Rain Cap (ensure cap is at least 3ft (91cm) above the roof at the lowest point)
2 ft (61 cm)
Roof Flashing Roof Rafter Fire Stop with Support Collar Ceiling Joist
5. Install the fresh air intake pipe. 6. Install the tee with clean out. 7. Install the pellet vent upward from there. When you reach the ceiling, make sure that the vent goes through the ceiling fire stop. Maintain a 100mm (4”) distance to combustibles and keep attic insulation away from the vent pipe. Maintain an effective vapor barrier. 8. Finally, extend the pellet vent to go through the roof flashing. 9. Ensure that the rain cap is approximately 900 mm (36”) above the roof.
Vertical Vent Pipe
Clean Out Tee with Pipe Adapter EF 5
NOTE: All vent sections must maintain 3 inches (7.6 cm) clearances to combustibles.
Figure 14: Inside Vertical Installation.
Outside Vertical Installations: To accomplish a outside vertical pipe installation, follow steps 1 through 5 in the “Inside Vertical Installations - Freestanding” section and then finish it by performing the following (refer to Figure 15). 1. Install a tee with clean out on the outside of the house. 2. Install vent pipe upward from the tee. Make sure that you install support brackets to keep the vent straight and secure. 3. Install ceiling thimble and secure the flashing as you go through the roof. 4. Ensure that the rain cap is approximately 900 mm (36”) above the roof.
16
Installation Rain cap Flashing 24" (61 cm)
4" (10cm)
3" (7.5 cm) Clearance Support bracket Tee with cleanout
Type "L" vent Fresh air intake Figure 15: Outside Vertical Installation.
Hearth Mount Installation: Rain Cap
Seal Plate
Existing Masonary Flue Vent Pipe (single wall stainless flex pipe or PL vent)
Refer to Figures 16. 1. Lock fireplace damper in the open position. 2. Install a positive flue connector at the fireplace dampers. 3. Connect a tee or a 90° elbow to the exhaust pipe. 4. Install flexible stainless steel liner or listed pellet vent to the top of the chimney.
Flexible Vent Connector (Use this 5 ft section of pipe to vent past fireplace damper or smoke shelf) Fireplace Damper Location Clean Out Tee Existing Fireplace EF 5
Figure 16: Hearth mount installation.
17
Installation Exterior Mounted Exhaust Blower: The Evolution can be equipped with an externally mounted exhaust blower. This optional kit includes all components necessary to install the exhaust blower on any vertical wall surface. Choose a location for your stove that meets the requirements stated in your manual and allows installation with the least amount of interference with house framing, plumbing, wiring, etc. Included in the Exterior Mounted Exhaust Blower Kit are: 1 - Exhaust blower housing box. 1 - Blower cover plate. 1 - Hardware bag Figure 17: Exterior Blower Kit.
1. Remove the left hand cabinet side by removing the two (2) screws down the front. Loosen the three screws on the back of the cabinet side and remove panel. 2. Loosen the six (6) screws that hold the back grill in place. Lift the back grill off the screws. 3. Disconnect the Exhaust blower wires from the wire harness. Remove the exhaust blower motor from the housing; six (6) screws. Cover hole in housing with cover plate provided (see Figure 18). Figure 18: Exterior Blower Kit.
4. Remove the cover from the exhaust blower housing box. 5. Install the exhaust blower housing box into the pipe placed through the wall thimble, seal with high temperature silicone. Fasten the box to the wall with (4) four screws, seal edges of box to wall with clear silicone. 6. Drill a hole through the wall thimble plate for the electrical wires. Pass the armored cable through the wall thimble. Use the strain relief provided. Do not pass cable through vent hole. 7. Install the Exhaust Blower motor into the external exhaust blower housing box. Make the electrical connections to the wire harness and exhaust blower. 8. Replace the cover on the Exhaust Box and the back grill of the stove and ensure the screws are tightened down.
Figure 19: Exterior Blower Kit cut-through.
18
9. Install vertical pipe as instructed in appropriate section.
Installation Typical Through Wall With Exterior Blower Kit Installation - Horizontal Termination:
EF 5
90° Elbow 45°Elbow with screen or stainless steel termination hood 2ft Riser Pipe Adaptor Electrical Cable
Exterior Blower and Housing
Figure 20: Through Wall Installation with Exterior Blower Kit.
NOTE: Ensure that all interior vent connections are sealed by placing a small bead of high temperature silicone around each chimney connection. Also ensure that all vertical vent sections are properly supported and that all clearances to combustibles are maintained in accordance with the vent manufacturer’s specifications.
Wall Strap
To supply power to the exhaust Figure 21: Through Wall Installation with Exterior Blower Kit; Side View.
Install an amour coated electrical cable from the exhaust blower housing, through the wall thimble plate and attach to the pre drilled hole in the left hand rear hopper pillar. Hook up to wires from the exhaust blower wiring harness. All electrical connections must be in accordance to local code requirements 19
Installation Typical Through Wall With Exterior Blower Kit Installation - Vertical Termination: Roof Sheathing
Rain Cap Roof Flashing
Roof Rafters
Follow the previous pages for through wall installations. Ensure that vent pipe is properly secured to wall using wall straps. Maintain clearances to combustibles on vent pipe as well as unit.
Ceiling Joists
Vent Pipe
Exterior Wall Sheathing
Outside Vent Termination
EF5
Figure 22: Through Wall Installation with Exterior Blower Kit; Vertical Termination.
Thermostat Installation: 1. Install the wall thermostat in a location that is not to close too the unit but will effectively heat the desired area. 2. Install a 12 or 24 Volt Thermostat using an 18 x 2 gauge wire from the unit to the thermostat.
Remove jumper wire and install thermostat wires here.
Figure 23: Thermostat wire placement.
20
If the unit has been placed in the HI / LOW mode, the unit will be taken to a low or idle setting when the thermostat is not calling for heat. When the thermostat calls for heat, the unit will go to the setting that is displayed on the control board Heat Indicator. If the heating load is not great enough when the stove is on low, the high limit switch will turn the stove off and the switch will have to be manually reset. To reset the high limit switch, remove the right cabinet side. The switch is found behind the control panel. Avoid setting off the high limit switch.
Installation Slider/Damper Set-Up: This is used to regulate the airflow through the pellet stove. The slider damper should be set by a trained technician using magnehelic. The slider damper is located behind the left side panel. To open the left side panel, undo the one screw located in the upper front corner of the cabinet side between the louvers. Also loosen three screws down the back of the side panel. The combustion exhaust blower is a variable speed blower controlled by the heat output button. This blower will decrease the vacuum pressure inside the stove and as the heat output button is turned down. The vacuum pressure inside the firebox will increase as the combustion exhaust blower increases in speed (higher heat output setting).
Air Intake Box Exhaust Channel Slider Damper Exhaust Blower
If the fire should happen to go out Figure 24: Slider/Damper Plate in Unit. and the heat output indicator has been set on the lowest setting, the Slider Damper should be pushed in slightly, decreasing the air in the firebox. If, after long periods of burning, the fire builds up and overflows the burn pot or there is a build up of clinkers, this would be a sign that the pellet quality is poor, this requires more primary air, the slider damper must be pulled out to compensate. Pulling the slider damper out gives the fire more air. The easiest way to make sure that an efficient flame is achieved is to understand the characteristics of the fire. • A tall, lazy flame with dark orange tips requires more air – Open slider (pull out) slightly. • A short, brisk flame, like a blowtorch, has too much air Figure 25: Efficient Flame. – Close slider (push in) slightly. • If the flame is in the middle of these two characteristics with a bright yellow/orange, active flame with no black tips then the air is set for proper operation (see Figure 25). SPECIAL NOTES: Pellet quality is a major factor in how the Pellet stove will operate. If the pellets have a high moisture content or ash content the fire will be less efficient and has a higher possibility of the fire building up and creating clinkers (hard ash build-up). IMPORTANT: Taking a reading of vacuum pressure inside the firebox with a magnehelic gauge should be used to set the slider for best combustion. The slider damper should be set only on a hot stove (operating for thirty (30) minutes or more) by using a Magnahelic Pressure Gauge to measuring the pressure in the firebox. The best settings are a reading of approximately 27.4 - 29.9 Pa (0.11 - 0.12 inches of water column) on the high fire setting. Some fuels may require higher or lower settings. The reading can be taken from the 3 mm (⅛”) hole located on the front of the unit below the ash shelf.
21
Troubleshooting DO NOT: ● Service the stove with wet hands. The stove is an electrical appliance, which may pose a shock hazard if handled improperly. Only qualified technicians should deal with possible internal electrical failures. ● Do not remove from the firebox any screws without penetrating oil lubrication. WHAT TO DO IF: 1. The stove will not start. 2. The stove will not operate when hot. 3. The exhaust blower will not function normally. 4. Light # 2 on Heat output bar flashing. 5. Auger light flashes but auger motor does not turn at all 6. The 93°C (200°F) high limit temperature sensor has tripped. 7. The convection blower will not function normally. 8. Ignitor - the pellets will not light. 9. Control settings (Heat Level) has no effect on the fire. 10. The stove keeps going out. *NOTE: All troubleshooting procedures should be carried out by qualified technicians or installers. 1. The stove will not start. Make sure the stove is plugged in and the wall outlet is supplying power.. If the Control Board has been placed in the AUTO /OFF thermostat mode, then turn the thermostat up or timer ON to call for heat. Ensure the burn pot liner is correctly placed in the burn pot Check the Heat Level Indicator. - If the # 2 light is flashing (see the # 2 light is flashing) Check the fuse on the circuit board. If the unit still does not start, contact your local service dealer for service. 2. The stove will not operate when hot. Check the Heat Level Indicator if a fire is not detected, or if the fire has gone out the #3 light will flash because the Exhaust Temperature Sensor’s contacts have opened. Check the hopper for fuel. Incorrect air damper setting. - Excessive air may consume the fire too quickly before the next drop of fuel, leaving completely unburned fuel in the burn pot liner. - Insufficient air will cause build up, further restricting the air flow through the Burn Pot Liner. This in turn will cause the fuel to burn cold and very slowly. Fuel may build up and smother the fire. In this case clean the burn pot. (NOTE: unit may require a change to the vent system or installation of fresh air to correct Air to Fuel ratio problems). Combustion Blower failure. - The Combustion Blower is not turning fast enough to generate the proper vacuum in the fire box. Visual Check – is the blower motor turning. Check the Exhaust Blower voltage across the blower wires (>=220V on #5 setting and >= 165V on #1 setting). – Replace the Circuit Board if the Voltage reading is less than 165 V. with a line voltage >220 V AC. Check Vacuum levels in the exhaust channel by bypassing the Vacuum Switch, then remove the Vacuum hose from Vacuum Switch. Check exhaust vacuum readings by placing the open end of the Vacuum Hose on a Magnahelic Gauge (readings must be above 24.9 Pa (.10” W.C.) on low fire). If the motor fails to reach a 24.9 Pa (.10” W.C.) readings, then replace the Combustion Blower. 22
Troubleshooting Poor Quality Fuel – Insufficient energy in the fuel to produce enough heat to keep the stove burning or operational. Exhaust Temperature Sensor failure. – Bypass sensor located on Exhaust Blower if stove now operates properly, the unit may require cleaning or a new sensor. Contact your local dealer for service. Check the fuse on the circuit board. 3. The exhaust motor will not function normally. Open the left side access panel; check all connections against the wiring diagram. See “2. The stove will not operate when hot.” section. 4. Light # 2 on Heat output bar flashing (The Vacuum Switch contacts have opened for more than 15 sec.) Pinch, break or blockage in Vacuum Hose - Check hose for pinch points or damage, replace or re-route as required. Blow out Vacuum Hose Blocked Hose Barb on Exhaust Channel - Use a paper clip to clean out Hose Barb or remove the Vacuum Hose from the Vacuum Switch and blow into the hose to remove blockage. Blocked exhaust / venting system - Have stove and venting cleaned and inspected. Severe negative pressure in area where unit is installed - Check the operation by opening a window, does this solve the problem? If it does, install fresh air intake to unit or room. Venting system may require vertical section to move termination into a low pressure zone. Vacuum Switch failure - Bypass the vacuum switch, if this corrects the problem check for above problems before replacing the Vacuum Switch. Damage to gray wires between Circuit Board and Vacuum Switch - Inspect wires and connectors Combustion Blower failure - The Combustion Blower is not turning fast enough to generate the proper vacuum in the Exhaust Channel. Visual Check; is the blower motor turning? Check the Exhaust Blower voltage across the blower wires (>=220V on #5 setting and >= 165V on #1 setting). – Replace the Circuit Board if the Voltage reading is less than 165 V. with a line voltage >220 V AC. Check Vacuum levels in the exhaust channel by bypassing the vacuum switch, then remove the Vacuum hose from Vacuum Switch. Check exhaust vacuum readings by placing the open end of the Vacuum Hose on a Magnahelic Gauge. (readings must be above 24.9 Pa (.10” W.C.) on low fire). If the motor fails to reach a 24.9 Pa (.10” W.C.) readings, then replace the Combustion Blower To reset Circuit Board after a trouble code - push the ON/OFF button 5. Auger light flashes but auger motor does not turn at all. If the Auger gear box does not turn but the motor’s armature does try to spin then the auger is jammed. – Try to break apart jam by poking at the jam through the drop tube. If this fails then empty the hopper and remove the Auger Cover **Remember to re-seal the cover after installation** Check the fuse on the circuit board. 6. The 93°C (200°F) high limit temperature sensor has tripped. Reset sensor and determine cause – was it Convection Blower failure or 71°C (160°F) Temperature Sensor failure? Bypass the 71°C (160°F) sensor, does the Convection blower come on high if not replace the blower? If yes, replace sensor (located on the left side of the firewall). Check the fuse on the circuit board.
23
Troubleshooting 7. The convection blower will not function normally. Clean all grill openings at the back and below unit . Press the fan button; does the fan come on? Press again to verify that the blower turns on; if, not contact your local dealer for service. 8. Ignitor- the pellets will not light. Everything else in the stove operates but the ignitor will not light the pellets. Make sure the burn pot liner is up tight and square to the ignitor tube by pushing the burn pot back against the ignitor tube. Check to see if the exhaust blower is operating. If not, contact your local dealer for service. Check the fuse on the circuit board. NOTE: The ignitor should be bright orange in color. If not replace the ignitor. 9. Control settings (Heat Level) has no effect on the fire. NOTE: If the system light is flashing the Control Board has complete control of the unit. When the units system light becomes solid then control of the unit is given back to the operator. If there is no control of the Heat Level button make sure the Thermostat/Timer is calling for heat. Call your local dealer for service. 10. The stove keeps going out. If the stove goes out and leaves fresh unburned pellets or cigarette-like ashes in the burn pot liner, the fire is going out before the stove shuts off. Check to see that the Slider / Damper is in the correct position. Turn the Heat Level up slightly (poor quality pellets will require slightly higher settings). Set the auger trim till the #1 and #5 lights are illuminated. If the stove goes out and there are partially burned pellets left in the burn pot liner, the stove has shut down due to a lack of air, exhaust temperature, or power failure. Adjust the Slider / Damper. Check to see if the stove needs a more complete cleaning. Turn the Heat Level up slightly (poor quality pellets will require slightly higher settings). Did the power go out? Contact your local Dealer for service.
24
Wiring Diagram Armor Cable Supplied
Optional Exterior Exhaust Blower
Grey Grey
Black
Combustion Blower
Vacuum Switch
White
White Blue
Brown Exhaust Temperature Sensor
Power Cord
Brown Ground
Thermostat
5 Amp Fuse
Black White Orange Orange Purple Blue Yellow Red Grey Grey Brown Brown Red Red
115V White 220V Blue
115V Black 220V Brown
Connect Thermostat Here
Hot
Red White
Black Black
Common Ignitor
Purple White
Yellow White Orange Orange
Convection Blower
Auger Motor High Limit Temperature Sensor
25
Parts List Reference # 1 2
Description
Part #
120°F (49°C) Ceramic Fan Temperature Sensor
EC-001
Window Channel Tape - 1.8m (72”)
EC-058
Auger Motor - 220V Combustion Blower Mounting Gasket
EF-011
Combustion Blower Housing Gasket (Circular)
EF-012
3
High Limit Temp Sensor 200°F (93°C) Manual Reset
4
Vacuum Switch - 220V
5
EF-016 EF-017-220V
Silicone Hose
EF-018
Aluminum Hose Barb
EF-019
Shoulder Bolt, Hardened Bush & Nut (SET of 2)
EF-124
Ash Pan Latch
50-2588
Pedestal & Ash Pan Gasket - 10’ (305 cm)
EF-208
Both Side Panels With Hopper Lid - Stainless Steel
-
6
Burn Pot
EF5-128
7
Ash Pan
EF5-129
8
Ash Pan Cover
EF5-131
9
Glass Retainer Set
EF5-133
10
Door Handle
EF5-134
11
Door Hinge Bracket
EF5-135
12
Door Only - Painted
EF5-136
13
Heat Exchange Rod
EF5-138
14
Hopper Lid - Painted
EF5-140
14
Hopper Lid - Stainless Steel
15
External Exhaust Back
EF5-143
16
External Exhaust Box
EF5-144
17
External Exhaust Bottom
EF5-145
18
NZ Power Cord - 220V
20-011
18
IEC Power Cord - 220V
-
19
Door Assembly Complete
20-014
Hardened Bushing
20-020
20
Glass With Gasket (356 mm x 356 mm)
20-023
21
Cabinet Side Left - Stainless Steel
21
Cabinet Side Left - Painted
22
Cabinet Side Right - Stainless Steel
22
Cabinet Side Right - Painted
20-032
23
Cast Top
20-038
Door Gasket - 7ft (213 m)
50-088
Top Louver Set - Nickel
50-097
24
26
EF-001-220V
-
20-031 -
Parts List Reference # 25
Description
Part #
Ash Shelf Louver
50-162
Slider Damper Rod & Knob
50-293
Top Glass Retainer
50-294
Control Panel Touch Latch
50-323
Circuit Board Wire Harness
50-332
Hopper Guard
50-333
26
Convection Blower - 220V
50-513
27
Convection Blower Mount & Hardware
50-585
28
External Exhaust Kit (80mm Pipe)
50-492
29
300 Watt Ignitor - 220V
50-3293
30
IEC Power Cord Inlet Socket
31
-
Circuit Board 5 Amp Fuse - 220V (Pair)
50-834
Auger Plate With Bushing
50-899
Exhaust Blower Assembly - 220V
50-900
Auger Motor Mount
50-1370
32
Burn Pot Liner - High Ash
33
Auger with paddles
50-1085
34
Back Grill
50-1222
Burnpot Scrapper Tool
50-1254
End Cap with ½” Bushing
-
-
35
Levelling Legs (Set of 4)
50-1342
36
Hopper Lid Hinge (4 Piece Set)
50-1376
37
Firebox Brick Liner - Square Drop Tube
50-1411
38
Firebox Panel Set With Inslulation - Square Drop Tube
50-1474
39
Control Panel Recessed
50-2405
40
Control Panel Decal
50-1967
41
Circuit Board with Thermostat Switch 3sec On Time 230V
50-1964
Gloves
50-1525
42
Exhaust Starter Tube 80mm x 2½” Long x 15°
50-1566
42
Exhaust Starter Tube 3” x 2½” Long x 15°
50-1368
Exhaust Starter Tube Gasket
50-1448
Hearth Pad
EF5-103
Owner’s Manual - NZ
50-1749
Technical Manual - NZ
50-1750
44
Slider Damper Plate
50-1579
45
EMI Filter [Electrical]
50-1584
43
27
Parts Diagram - Components
33
1
31
3
39
41 4
40
29 2
30
27
45 26
EF5 EVOLUTION NZ - Components September 2009
28
18
17
34
21
42
44
35
September 2009
EF5 EVOLUTION NZ - Steel Components
15
28
16
36
43
23
13
14
7
22
5
8
38
25 11
37
12
24 32 6
19
9 20
10
Parts Diagram - Steel
29
Installation Data Sheet The following information must be recorded by the installer for warranty purposes and future reference. NAME OF OWNER:
NAME OF DEALER:
_________________________________________
_________________________________________
ADDRESS:
ADDRESS:
_________________________________________
_________________________________________
_________________________________________
_________________________________________
_________________________________________
_________________________________________
PHONE:___________________________________
PHONE:___________________________________
MODEL:___________________________________
NAME OF INSTALLER:
SERIAL NUMBER:___________________________ DATE OF PURCHASE: _____________
_________________________________________
(dd/mm/yyyy)
DATE OF INSTALLATION:___________(dd/mm/yyyy)
ADDRESS:
MAGNEHELIC AT INSTALL:___________________
_________________________________________
INSTALLER’S SIGNATURE:
_________________________________________
_________________________________________
_________________________________________ PHONE:___________________________________
WARRANTY: If you have any concerns with your unit please contact the dealer where you purchased the stove. MANUFACTURED BY: SHERWOOD INDUSTRIES LTD.
6782 OLDFIELD RD. SAANICHTON, BC, CANADA V8M 2A3
September 8, 2016 C-14987
30