Preview only show first 10 pages with watermark. For full document please download

Ewb 1000 Installation Guide

   EMBED


Share

Transcript

NTc:om for RTxA n. es O o r P t IM w.e 000 Seri g EWB 1000 • Installation Guide w LP 1 tin T nnec ce. r to w Refe ompleteefore co er sour w the cr guide b the po use oduct to r the p Overview The Extron EWB 1000 wall box is an optional accessory for mounting the TLP 1000MV touchpanel onto the surface of various wall types (such as drywall, wood, or masonry) where it is not possible to embed the touchpanel in the wall. The EWB 1000 has knockouts that accept raceways or conduit for running cables over the surface of the wall to the touchpanel. Planning The following items are required for installation, but are not supplied: Extron EWB 1000 Wall Box zz Extron TLP 1000MV Extron TLP 1000MV zz Four mounting screws (Extron recommends a minimum length of 1 inch) zz Power drill zz Drill bit that is appropriate for Extron TLP 1000MV Faceplate wall type zz Conduit or surface raceway to carry cables zz Screwdriver zz Level Mounting Suggestions for Different Wall Types Choose a type of screw or bolt that is appropriate for the wall on which you are mounting the EWB 1000 (see table below). The mounting holes in the back of the EWB 1000 accommodate screws up to ¼ inch in diameter. Wall Type Fasteners Min. Size Fastener Quantity Drill Bit Size Notes Drywall Toggle bolts 3/16 inch 4 1/2 inch Min. 3/8 inch wall thickness Wood (solid wall or stud) Wood screws #10 screw with a washer 4 1/16 inch wood bit Min. 3/8 inch wall thickness Masonry Masonry screws 1/4 inch 4 3/16 inch masonry bit Do not mount to masonry joints EWB 1000 • Installation Guide (Continued) Mounting the EWB 1000 1. Decide where to mount the EWB 1000. If mounting to standard wood wall studs, locate the center of the studs. 2. Place the EWB 1000 against the wall at the mounting location. Use a level to ensure the box is horizontal and mark the position of the four holes. 4 3. If required, drill four holes into the wall. 4. Insert four screws (see the table on the previous page) and attach the EWB 1000 to the wall. Mounting Screws (4) 5. Remove the required knockout and run conduit or raceway to the EWB 1000. 6. Run cables through the conduit and the EWB 1000 knockout. Mounting the TLP 1000MV 1. Remove the faceplate from the TouchLink panel. 2. Attach the cables to the back of the TLP 1000MV (see the TLP 1000MV and TLP 1000TV User Guide). 3. Secure the TLP 1000MV to the EWB 10000 using the four 6-32 screws provided. 2 5 4. Configure the TouchPanel as described in the TLP 1000MV and TLP 1000TV User Guide. 5. Snap the faceplate into position (four clips on each side). 3 Extron USA - West Headquarters Extron USA - East Extron Europe Extron Asia Extron Japan +800.633.9876 Inside USA and Canada Only +800.633.9876 Inside USA and Canada Only +800.3987.6673 Inside Europe Only +800.7339.8766 Inside Asia Only +81.3.3511.7655 +400.883.1568 +81.3.3511.7656 FAX Inside China Only +65.6383.4400 +1.714.491.1500 +1.919.863.1794 +31.33.453.4040 +65.6383.4664 FAX +1.714.491.1517 FAX +1.919.863.1797 FAX +31.33.453.4050 FAX Extron China Extron Middle East +971.4.2991800 +971.4.2991880 FAX +86.21.3760.1568 +86.21.3760.1566 FAX © 2011 Extron Electronics All rights reserved. www.extron.com 68-2096-01 Rev. A 04 11