Transcript
EWC485 Range Test
Stronger Signal Less Interference
1 The Elite Processor MUST have this sticker to use the wireless communicator. Firmware version 6.11 or later.
WIRELESS
communicator
Compatible
2 Screw antennas on TIGHT.
WIRE com
LESS
mu
Compnicator atible
Loose antennas will affect the signal strength!
3 Unlock the units and open doors. 4 Set both units to TEST MODE.
ONLY test 2 units at a time, turn ALL other units OFF!
5 Set one unit to LOCAL connection and the other to REMOTE connection. The “LOCAL
More Interference Weak Signal
connection” unit is near the telephone entry system.
6 Temporarily stick the supplied battery packs on the outside of each unit with the double stick tape. Feed the wires through an existing hole on back of the unit. It is VERY important that BOTH battery packs produce 12VDC, weak batteries will produce undependable test results.
If a continuous tone is NOT heard during the range test:
7 Both units must be set to the same FACILITY FREQUENCY. If they are not the same, follow Step 55 on the manual to set the frequencies on both units.
Make sure the antennas are screwed on tight.
8 Connect the battery wires to the removable power connector. When BOTH
Try moving the remote unit 15-20 feet in several directions, away from metal surfaces or any obstructions.
units have been powered up, a CONTINUOUS tone will be heard from both units indicating strong signals are being transmitted and received.
Try moving the local unit 15-20 feet in several directions. Try raising the units up, above the rooftops if necessary to clear any obstacles. The higher the units, the less interference they will encounter. Keep antenna clear from metal surfaces or any obstructions that can weaken the signal strength.
9 Close and lock the units placing the LOCAL unit in its final position near the telephone entry system. Recommend minimum 8 feet above ground.
10 Take the REMOTE unit to the desired remote access
Test the battery packs with a voltmeter for 12VDC. Weak batteries will produce undependable test results. Try changing the FACILITY FREQUENCY of the units. Follow Step 55 5
Part Number 41A6082
point and place it in its final position. A continuous tone should be heard indicating that the range is OK. The units can now be permanently installed in their current positions. Use the supplied transformer for permanent power. Discard battery pack.
on the manual. Both units MUST be
set to the same frequency.
If a continuous tone is not achieved after all previous suggestions have been tried, call for toll free technical support: 1-800-582-2806
11 Set the units back to OPERATING MODE.
4 5 ®
114A2969
© 2004 The Chamberlain Group, Inc. All Rights Reserved
™ 845 Larch Avenue Elmhurst, Illinois 60126-1196
EWC485 Installation Optional Antenna Cover Protects against vandalism. Part Number 41A6083
Daisy Chain RS485 Devices Together
To Next RS485 Device
Use Separate Transformer 12 Vac, 20VA
+ – Gnd
POWER INPUT SURGE SUPPRESSOR Elite Entry Phone
RS485
®
eliteentryphone.com
SURGE SUPPRESSOR
POWER INPUT SURGE SUPPRESSOR P/N: TAPISS
14“
OUT RS-485 (+)
IN BROWN: RS-485 (+)
RS-485 (-)
BLUE: RS-485 (-)
RS-485 GND
YELLOW: RS-485 GND GREEN: CHASSIS GND
7“
+ – Gnd 3.25“
Sample Mountings
12 AWG Wire
Use Provided Transformer 12 Vac, 20VA 1.8“ 4.25“
Wiring 1 RS485 Device
Back View Use Separate Transformer 12 Vac, 20VA
Suggestion: Seal holes of box with sealant when finished wiring.
Do not share transformer with any other devices.
POWER INPUT SURGE SUPPRESSOR Elite Entry Phone
RS485
22 AWG Shielded Wire
®
eliteentryphone.com
SURGE SUPPRESSOR
POWER INPUT SURGE SUPPRESSOR P/N: TAPISS
OUT
+ – Gnd
RS-485 (+)
IN BROWN: RS-485 (+)
RS-485 (-)
BLUE: RS-485 (-)
RS-485 GND
YELLOW: RS-485 GND GREEN: CHASSIS GND
Mounting Bolt Clearance
RS485 Wire Run
BUILT-IN SURGE PROTECTION
.66“
12 AWG Wire
3 Feet Max.
WIRELESS
communicator
Compatible WIRE com
LESS
mun
Com icator patible
12 AWG Wire Processor MUST have this sticker to use the wireless communicator. Firmware version 6.11 or later. 3“
Side View
The earth ground rod must be located within 3 feet from the wireless communicator.
Make sure the unit is set to OPERATING MODE. ®
114A2969
Call for toll free technical support: 1-800-582-2806
© 2004 The Chamberlain Group, Inc. All Rights Reserved
™ 845 Larch Avenue Elmhurst, Illinois 60126-1196