Preview only show first 10 pages with watermark. For full document please download

Ex Magnetic Sensors Ex Rc M14 1w

   EMBED


Share

Transcript

Ex magnetic sensors Ex RC M14 1W - 2m Material number: 1189237 (Material number old: 21433201) Features/Options: • • • • • • Switching distance up to 30 mm depending on the actuating Ex zone 1 and 21 Brass enclosure, nickeled Long life 1 Reed contact Actuation from front magnet • With pre-wired cable • 2 hexagon nuts are provided • N.B.: Please state required approvals for Russia and Brazil with your order! Notes • 2 mounting nuts are included in delivery • The actuator is not included in the delivery of the switches Dimensions Technical data Standards EN 60947-5-1; EN 60079-0; EN 60079-18 Enclosure brass, nickeled Actuator series M permanent magnet Degree of protection IP 67 to IEC/EN 60529 Contact material Rhodium Switching system reed contacts Switching elements change-over contact Connection pre-wired cable H05VV-F Cable cross-section 4 x 0.75 mm² Cable length 2m Switching voltage 250 VAC Switching current 1.5 A Short-circuit current Ik max. 2 A Switching capacity max. 50 W Utilisation category AC-12; DC-12 Bounce duration 0,3 … 0,6 ms Ambient temperature –20 °C … +70 °C Mechanical life > 1 million operations Electrical life 106 … 109 operations Vibration resistance 10 … 50 g Impact energy max. 4 J Errors and omissions excepted. Printed: 21.10.2017 Page 1/3 steute Schaltgeräte GmbH & Co. KG Brückenstraße 91 32584 Löhne, Deutschland Telefon +49 (0) 5731 745-0 [email protected] Telefax +49 (0) 5731 745-200 www.steute.com Ex magnetic sensors Ex RC M14 1W - 2m Material number: 1189237 (Material number old: 21433201) Technical data Note Switch must be protected from mechanical damage! Ex marking L II 2G Ex mb IIC T6 Gb, L II 2D Ex mb IIIC T80 °C Db IECEx Ex mb IIC T6 Gb Ex mb IIIC T80 °C Db Approvals DMT 01 ATEX E 058 X IECEx BVS 07.0007 X Ö Weight f 318 g Contact diagram Errors and omissions excepted. Printed: 21.10.2017 Page 2/3 steute Schaltgeräte GmbH & Co. KG Brückenstraße 91 32584 Löhne, Deutschland Telefon +49 (0) 5731 745-0 [email protected] Telefax +49 (0) 5731 745-200 www.steute.com Ex magnetic sensors Ex RC M14 1W - 2m Material number: 1189237 (Material number old: 21433201) Directive for the protection of reed contacts With unknown input currents, input capacitances we recommend the interposing of an interface relais. When using Finderrelais series 49, in the following you will find some proposals to protect the reed contact against overload. Inductive load: Inductive load at DC voltage Inductive load at AC voltage S1 S1 + coil voltage 24 VDC 24 VAC 230 VAC serial resistor Rs 24 - 230V AC 27 Ohm 39 Ohm 330 Ohm / 0.6 W RS 62 KOhm Additionally Fa.Finder recommends a parallel resistor for the 230V-type Recovery diode e.g. 1N4007 24 - 250V DC - Due to the cable capacitances it is necessary to place the series resistors as near as possible to the reed contact, in general the next terminal point (junction box). Finder interface relais series 49 with modul series 99.80 RC network according to operating voltage R C Capacitive load, cable length more than 5m or connenction to process control system with capacitive input: Current limiting at capacitive load Current limiting at electronic timing relay e.g. PLC, PCS and cable length > 5 m S1 + S1 Rs C1 Rs C1 230V AC 24V DC PLC Rs = 22 Ohm Rs = 220 Ohm (230V AC) C1 = internal capacity C1 = internal capacity It is to observe the electrical data (switching voltage, switching current, switching capacity) Errors and omissions excepted. Printed: 21.10.2017 Page 3/3 steute Schaltgeräte GmbH & Co. KG Brückenstraße 91 32584 Löhne, Deutschland Telefon +49 (0) 5731 745-0 [email protected] Telefax +49 (0) 5731 745-200 www.steute.com