Transcript
Ex magnetic sensors Ex RC M14 1W - 2m Material number: 1189237 (Material number old: 21433201) Features/Options: • • • • •
• Switching distance up to 30 mm depending on the actuating
Ex zone 1 and 21 Brass enclosure, nickeled Long life 1 Reed contact Actuation from front
magnet • With pre-wired cable • 2 hexagon nuts are provided • N.B.: Please state required approvals for Russia and Brazil with your order!
Notes • 2 mounting nuts are included in delivery • The actuator is not included in the delivery of the switches
Dimensions
Technical data Standards
EN 60947-5-1; EN 60079-0; EN 60079-18
Enclosure
brass, nickeled
Actuator
series M permanent magnet
Degree of protection
IP 67 to IEC/EN 60529
Contact material
Rhodium
Switching system
reed contacts
Switching elements
change-over contact
Connection
pre-wired cable H05VV-F
Cable cross-section
4 x 0.75 mm²
Cable length
2m
Switching voltage
250 VAC
Switching current
1.5 A
Short-circuit current Ik
max. 2 A
Switching capacity
max. 50 W
Utilisation category
AC-12; DC-12
Bounce duration
0,3 … 0,6 ms
Ambient temperature
–20 °C … +70 °C
Mechanical life
> 1 million operations
Electrical life
106 … 109 operations
Vibration resistance
10 … 50 g
Impact energy
max. 4 J
Errors and omissions excepted. Printed: 21.10.2017
Page 1/3
steute Schaltgeräte GmbH & Co. KG
Brückenstraße 91 32584 Löhne, Deutschland
Telefon +49 (0) 5731 745-0
[email protected] Telefax +49 (0) 5731 745-200 www.steute.com
Ex magnetic sensors Ex RC M14 1W - 2m Material number: 1189237 (Material number old: 21433201) Technical data Note
Switch must be protected from mechanical damage!
Ex marking
L II 2G Ex mb IIC T6 Gb, L II 2D Ex mb IIIC T80 °C Db IECEx Ex mb IIC T6 Gb Ex mb IIIC T80 °C Db
Approvals
DMT 01 ATEX E 058 X IECEx BVS 07.0007 X
Ö Weight
f
318 g
Contact diagram
Errors and omissions excepted. Printed: 21.10.2017
Page 2/3
steute Schaltgeräte GmbH & Co. KG
Brückenstraße 91 32584 Löhne, Deutschland
Telefon +49 (0) 5731 745-0
[email protected] Telefax +49 (0) 5731 745-200 www.steute.com
Ex magnetic sensors Ex RC M14 1W - 2m Material number: 1189237 (Material number old: 21433201) Directive for the protection of reed contacts
With unknown input currents, input capacitances we recommend the interposing of an interface relais. When using Finderrelais series 49, in the following you will find some proposals to protect the reed contact against overload.
Inductive load:
Inductive load at DC voltage
Inductive load at AC voltage S1
S1 +
coil voltage 24 VDC 24 VAC 230 VAC
serial resistor Rs
24 - 230V AC
27 Ohm 39 Ohm 330 Ohm / 0.6 W
RS
62 KOhm Additionally Fa.Finder recommends a parallel resistor for the 230V-type
Recovery diode e.g. 1N4007
24 - 250V DC
-
Due to the cable capacitances it is necessary to place the series resistors as near as possible to the reed contact, in general the next terminal point (junction box). Finder interface relais series 49 with modul series 99.80
RC network according to operating voltage
R C
Capacitive load, cable length more than 5m or connenction to process control system with capacitive input:
Current limiting at capacitive load
Current limiting at electronic timing relay
e.g. PLC, PCS and cable length > 5 m S1
+
S1
Rs C1
Rs C1
230V AC
24V DC
PLC
Rs = 22 Ohm
Rs = 220 Ohm (230V AC)
C1 = internal capacity
C1 = internal capacity
It is to observe the electrical data (switching voltage, switching current, switching capacity)
Errors and omissions excepted. Printed: 21.10.2017
Page 3/3
steute Schaltgeräte GmbH & Co. KG
Brückenstraße 91 32584 Löhne, Deutschland
Telefon +49 (0) 5731 745-0
[email protected] Telefax +49 (0) 5731 745-200 www.steute.com