Preview only show first 10 pages with watermark. For full document please download

Exclusive: 6*60a Large Current

   EMBED


Share

Transcript

K60 Series Protection Relay Test Set Catalogue Exclusive: 6*60A large current 1.Use modularization switch power and self-RD hi-fi digital amplifier, with capacity efficient more than 85%, high output power, low weight and small heating value, to make sure for long time and reliable ×10A output. Strong ability for overloading for reliable quality hardware. 2.Internal high-capacity SSD solid state disk, to make sure the normal running in the status of high speed moving or even tilting, so that the data will not lose when collision and shock. 3.Internal dual core CPU industrial PC, 9.7 inch large LED display screen, 1024×768 resolution, embedded Windows XPE system, to provide friendly interface for use for the onsite calibration at smart substations.. Functions Characteristic 1. 13 pcs of channels simultaneous output, that is to output 7 phase voltage and 6 phase current with different amplitude, frequency, phase; 2. With wave form distortion test function, judgment of wrong wiring alarm, self-locking, housing grounding alarm. 3. Provide convenient and prompt all software calibration for amplitude and phase, no need to open the housing to calibrate the output precision; 4. 0~300V/0 .6A remote aux. DC power output; 5. To test by manual or automatic mode for various types of voltage, current, frequency, power, impedance, harmonic, differential, simultaneous relays, and can simulate various types of failure to perform the experiment of distance, zero sequence and reclose test. With GPS trigger function, to perform the test of reserve supply, prompt switch, etc. 6. Internal GPS function; 7. Optional function for standard meter, transducer, energy meter, etc. K60 Series Tester Model List Model K6066 K6063 K6030 Current 6×30A 6×30A 6×60A 6×30A 6×30A 3×30A 3×30A K6066 K6066i K6066S K6063 K6063i K6030 K6030i K6066 Main Technical Parameters AC Voltage Source Output range Output power Precision Resolution 7-phase AC(L-N) 3-phase AC(L-L) 7×130 V (L-N) 2×600 V (L-L) 7×0~130V 3×0~260V 1×70 VA max 1×110 VA max ±2 mV (0.2 V~2 V) ±0.1% (2 V~130 V) 1mV AC Current Source Output range Output power 6-phase AC(L-N) 1 phase AC(6L-N) 6×0~30 A 1×0~100 A 6×30A(L-N) 6×220 VA max 1×30A(L-N) 1×450 VA max 1×100A(LN) 1×1000 VA max Voltage 7×130V 7×300V 7×130V 4×130V 4×300V 4×130V 4×300V ±1 mA (0.2A~0.5A) Precision ±0.1% (0.5A~20A) ±0.1% (20A~Imax) Resolution 1mA Frequency Output Range 5~1000 Hz <0.001 Hz (5~65 Hz) Precision <0.01 Hz (65~450 Hz) <0.02 Hz (450~1000 Hz) Resolution Phase Output 0.001 Hz Range -360°~360° Precision <0.2° Resolution 0.1° Timing Function Timing range 0.1 ms~1.5×105 s Timing accuracy ±1ms(0.001s~1s)±0.1%(1s~1.50× 105 s) DC voltage、DC current Range DC voltage Accuracy Range DC current Aux.DC Accuracy 0~300V/180W ±10mV (0.5 V~5 V) ±0.5% (5 V~300 V) 0~30A/300W ±5mA (0.2 A~1 A) ±0.5% (1 A~30 A) Voltage Source Range 0~300V/0.6A Binary Input Number 8pairs Compatible voltage 0V~250V Binary Output Number 4pairs Capacity 250V/3A (AC/DC) DC Measurement Input(Optional) Voltage Range 0~±10V,1MΩ Current Range 0~±20mA,15Ω Precision <0.05% RG AC Measurement Input(Optional) Voltage Range 0~130V,<0.2% RG Current Range 0~5A (Clamp-shape CT Connection),<0.5% RG Frequency Range 45~65 Hz,< 0.01 Hz Phase 0~360°,< 0.5° Harmonic 2~20times,<0.5% RG Synchronization Synchronization mode GPS Harmonic Superimposed Numbers 2~20times Power supply Rated voltage 220V Power supply range 88~264VAC,125~350VDC Power 1500 VA Power supply frequency 47Hz~63Hz Working Condition Working temperature -20℃~70℃ Humidity ≤95%, No condensation Weight & Size Weight 17.5 kg Size 360×480×190(mm) Online interface RJ45