Preview only show first 10 pages with watermark. For full document please download

Explosion Proof Analog Telephones

   EMBED


Share

Transcript

G U A R D I A N T E L E C O M Product and Services Guide Explosion Proof Analog Telephones Explosion proof equipment is intended for use in the highest hazardous area classifications. These products are designed and constructed to contain explosions within the equipment. This prevents an explosion from igniting the hazardous atmosphere outside the unit. The ultimate in protection for your personnel, equipment and property. PSG-8.2.3D SECTION ISO-9001:2008 Certification Today's Quality Creates Our Future w w w.guardiante l e co m .co m 2 V isit industrial sites around the world and you can find telephones and communication systems designed, manufactured, distributed and commissioned by Guardian Telecom. From certified and ruggedized telephone and paging endpoints, to loudspeakers & ringers, cable, accessories, acoustic booths and much more. Our product line is extensive and our knowledge in-depth. Guardian manufactures and assembles at our modern, ISO certified, CSA, UL and ATEX approved facility located east of the Canadian Rockies in Calgary, Alberta, Canada. Working closely with our customers has always been a cornerstone in our work ethic. It keeps us up to date on their evolving needs and requirements as they operate in a demanding and uncompromising industrial world. Guardian Telecom has completed its initial VoIP telephone product launch. As the IP world continues to evolve and grow, we will continue to invest both time and resources in design and testing to meet the stringent requirements that clients demand. The in-house channel-partner sales and technical teams are here to work directly with you or through our network of distributors and representatives, locally, nationally and globally. Take advantage of their practical experience and product knowledge to make informed decisions based on your communication needs, environmental factors, regulatory requirements, budget considerations, growth and scheduling. From individual telephone units to complete systems, our focus on customers’ distinct needs is also addressed by customizing products whenever practical. From features to colors, finishes to labels, graphics, parts, enclosures and more. Guardian can help guide you through the product selection process no matter how complex it is. We invite you to contact us to discuss your needs and see if our products & services will be the right fit. Toll free (North America) 1 800 363-8010 Tel 403 258-3100 Fax 403 253-4967 E-mail [email protected] Guardian Telecom's Product and Services Guide Catalogue is a compilation of individual Category Sections. They include an in-depth selection of Product Data Sheets from our extensive product lines including Analog and VoIP Telephones, Page/Talk, Cable, Talk/Back, PA/GA equipment, Acoustic Booths, Loudspeakers & Ringers and Accessories at the date of publication. 2-i Based on a policy of continuous improvement, Guardian is constantly evaluating and redesigning existing models, adding new features and introducing new products to the benefit of our customers. Additional information can be found on our website at www.guardiantelecom.com. Guardian Telecom Product and Services Guide www.guardiantelecom.com PSG-8.2.3D Explosion Proof Analog Telephones EXT-401 & EXT-401 Assembly with CE20 Ringer 2-1 Models with LINK & REDIAL Buttons and do not have Volume Control • P4011 Base Model † • P1011 CE20 Line Powered Ringer, Backplate • P4021 Ring Detect Relay (RDR) † • P1021 Ring Detect Relay (RDR), CE20 Line Powered Ringer, Backplate • P4022 Ring Detect Relay, Headset 1 • P4023 Headset (in lieu of Handset) 1 • P4036 Ring Detect Relay (RDR), Headset, CE20 Line Powered Ringer, Backplate • P4038 Headset, CE20 Line Powered Ringer, Backplate Models where Volume Control Buttons replace LINK & REDIAL Buttons • P4012 Base Model † • P4030 CE20 Line Powered Ringer, Backplate • P4031 Ring Detect Relay (RDR) † • P4032 Ring Detect Relay (RDR), CE20 Line Powered Ringer / Backplate • P4033 Headset (in lieu of Handset) † • P4034 Headset, CE20 Line Powered Ringer, Backplate • P4035 Headset, Ring Detect Relay (RDR) • P4037 Headset, Ring Detect Relay (RDR), CE20 Line Powered Ringer, Backplate † Telephone Requires External Signalling Device Recommended Products SR40/SR60 Explosion Proof 21-1 The EXT-401 Headset Kit is a field replacement for the standard handset on an EXT-401 phone. It provides clear communication in noisy environments and the 20’ (9.5m) cord allows mobility for user. Contact a qualified Guardian Telecom Channel Partner for details. CE20 Ringer 21-1 Guardian’s CE20 Explosion Proof Ringer is designed for use in hazardous areas where flammable gases, vapors or dust may be present. CE20 Ringer with Horn 21-1 With the addition of the horn the CE20 has a Type 4X weather rating and can produce up to 97dB of sound pressure level. HS-EXT-401 Intrinsically Safe EXT-401 Headset 25-11 The HS-EXT-401 Headset and the HSK-EXT-401 Headset Kit with hanger are field replacement for the standard handset on an EXT-401 phone. The rugged headset provides clear communication in noisy environments and the 20’ (9.5m) cord allows mobility for user. 2-ii Guardian Telecom Product and Services Guide — Explosion Proof Analog Telephones www.guardiantelecom.com 2-iii Guardian Telecom Product and Services Guide www.guardiantelecom.com PSG-8.2.3D EXT-401 Explosion Proof Telephone FEATURES and BENEFITS • Over-sized buttons for gloves-on operation • Corrosion and moisture resistant circuitry • Intrinsically safe handset with heavy duty cord • Field replaceable handset and fuse • Explosion proof, no isolation barrier required • Copper-free cast aluminum housing • Temperature range -40˚F to +140˚F (-40˚ to +60˚C) • Alternate models available with volume control in lieu of Link and Redial APPLICATIONS These telephones are designed for use in locations with the highest hazardous area classifications such as: EXT-401 Explosion Proof Telephone with CE20 Explosion Proof Ringer. • Chemical Plants • Petrochemical Plants • Offshore Drilling Rigs • Missile Silos • Gas Plants • Refineries • Fueling Stations • Bulk Loading Stations • Fertilizer Plants and more . . . • Defense & Aerospace Installations • Munitions Storage Depots • Land-based Drilling Rigs • Liquefied Natural Gas Terminals • Tankers and Tanker Depots • Oil & Gas Metering Facilities • Paint & Varnish Manufacturing Plants • Grain Processing & Similar Industries • Breweries and Distilleries INSTALLATION and CONNECTABILITY To provide flexibility and potential for growth, Guardian telephones are easily and economically connected to any telephone network by standard wiring and components. Guardian’s EXT-401 Explosion Proof Telephone provides safe and reliable communication in Class I Division 1 and Class II Division 1 & 2 areas. Voice quality is unaffected when phones are connected within 15,000 feet (~ 4,600 metres) of a main telephone switch accepting single line telephones. Maintaining safety standards may require use of special wiring conduits or other considerations. The phone can be factory set for either tone or pulse operation. ACCESSORIES and OPTIONS • 20 ft. (6m) Handset Cord – Field Replaceable Low Temperature Polymer Jacket • 22” (0.6m) Armored Handset Cord • Headset (Replaces Handset) ISO-9001:2008 Certification Today's Quality Creates Our Future 2-1 OVERALL DIMENSIONS 10.2" [258mm] 10.1" [257mm] 5.7" [144mm] 4.9" [124mm] 8.5" [216mm] GUARDIAN TELECOM INC. TELEPHONE FOR USE IN HAZARDOUS LOCATIONS CLASS I GROUPS B, C, & D CLASS I ZONE 1, GROUPS IIB+H2 CLASS II GROUPS E, F, & G LISTED ENCLOSURE TYPE 4 RECEPTACLE PROVIDES INTRINSICALLY SAFE OUTPUT USE ONLY MODEL 301SC OR 301SCPB HANDSET WITH THIS TELEPHONE 13X8 [Exia] Associated equipment Appareillage Connexe 158194 RELAY CONTACTS 10A 1/3HP 240V AC 10A 1/3HP 120V AC 10A 30V DC FUSE: 0.25A 48VDC - TYPE 2AG, FAST-ACTING SER. NO. 1 CAT. NO.: 401 REFER TO USER GUIDE FOR INSTALLATION MADE IN CANADA 8 DEF GHI JKL 5 MNO TUV WXY 4 PRS 7 8  0 OPER LINK RLS 3 6 9 # REDIAL 4 ABC 8 DEF 5 JKL MNO TUV WXY 7 8  0 13.5" [342mm] 1 ABC GHI PRS OPER LINK RLS 3 6 9 # 24.0" [610mm] US C REDIAL WARNING FIELD REPAIR NOT POSSIBLE. FOR SERVICE RETURN TO FACTORY. TO PREVENT IGNITION OF HAZARDOUS ATMOSPHERE, DISCONNECT FROM THE SUPPLY CIRCUIT BEFORE OPENING OR REPLACING FUSE. KEEP TIGHTLY CLOSED WHEN CIRCUITS KEEP TIGHTLY CLOSED WHEN CIRCUITS ARE ALIVE. ALL CONDUIT RUNS MUST BE SEALED WITHIN 18 INCHES (450 mm) OF THIS ENCLOSURE. BREAKING OF REAR BOLT SEALS VOIDS MANUFACTURER’S WARRANTY. SUBSTITUTION OF COMPONENTS MAY IMPAIR INTRINSIC SAFETY. ATTENTION CET APPAREIL NE PEUT ETRE REPARE A PIED D’OEUVRE. NE PAS L’OUVRIR LES BOULONS DOIVENT ETRE BIEN SERRES; EN CAS DE REMPLACEMENT DE LE PLOMB, LE TELEPHONE FAUT EXT-401 Explosion Proof Telephone EXT-401  Explosion Proof Telephone ENGINEERING SPECIFICATIONS COMPLIANCE ELECTRICAL PERFORMANCE Audio Range Frequency Response Dialing method Transmit Objective Loudness Rating (TOLR) Receiver Objective Loudness Rating (ROLR) – receiver volume at maximum – receiver volume at minimum Side Tone Objective Loudness Rating (SOLR) – receiver volume at maximum – receiver volume at minimum Ringer Equivalence Number-REN Flash Redial CE20 Ringer Output Set Impedance Maximum Loop 300 - 3400 Hz DTMF or 40/60 Pulse @10 PPS Nominal -38 +/ - 3 dB Nominal 50 +/- 3 dB 41.9 +/- 3 dB 55.4 +/- 3 dB Nominal 8 +/- 4 dB 7 +/- 4 dB 14 +/-4 dB 0.4A w/o RDR, 0.8B c/w RDR 600 mSec Timed Disconnect Maximum 13 Digits ≥75 dB 600 Ohms Nominal 15Kft ( ~ 4,600m ) of 22 AWG Wire ELECTRICAL REQUIREMENTS Ringer Sensitivity Line Voltage Loop Current Connection Method Fuse (Externally Accessible) 40 -100 V, 16 - 25 Hz 24 - 56 VDC 20 - 120 mA Sealed External Wire 0.25 Amp 2AG Fast Acting MECHANICAL SPECIFICATIONS Hook Switch ( Cradle Switch ) Life >1 000 000 Operations Body Construction Cast Copper Free Aluminum Finish Hybrid Powder Coat Finish Net Weight EXT-401 21.0 lbs ( 9.6 kg ) EXT-401 Assembly 32.0 lbs ( 14.5 kg ) Shipping Weight EXT-401 22.0 lbs ( 10 kg ) EXT-401 Assembly 33.0 lbs ( 15 kg ) Shipping Dimensions ( L x W x D ) EXT-401 16.0” x 10.5” x 9.5” ( 407 x 267 x 242 mm ) EXT-401 Assembly 15.0 “x 28.0” x 11.0” ( 381 x 711 x 280 mm ) Hand Set Construction High Impact ABS Hand Set Cord 10 ft ( 3m ) Field Replaceable Low Temperature Polymer Jacket Mounting Vertical Wall Microphone Dynamic Receiver Hearing Aid Compatible Hardware Material Stainless Steel 2-2 Models with Volume Control – 1012 6721 A CSA 158194 & UL E117495 Class I, Div. 1, Groups B, C and D; Class II, Div. 1 and 2, Groups E, F and G C22.2 No. 30 - M1986 / C22.2 No. 157 - 92 Intrinsically Safe and Non-incendive Equipment For Use in Hazardous Locations, Gaseous Mines, NRCan Certificate No. 976X ORDERING INFORMATION Warranty: One year parts and labor Order No. Description The following models have LINK & REDIAL Buttons, they do not have Volume Control P4011 Base Model* P1011 CE20 Line Powered Ringer / Backplate P4021 Ring Detect Relay (RDR)* P1021 Ring Detect Relay (RDR) / CE20 Line Powered Ringer / Backplate P4022 Ring Detect Relay / Headset P4023 Headset (in lieu of Handset) P4036 Ring Detect Relay (RDR) / Headset / CE20 Line Powered Ringer / Backplate P4038 Headset / CE20 Line Powered Ringer / Backplate On the following models Volume Control Buttons replace LINK & REDIAL P4012 Base Model* P4030 CE20 Line Powered Ringer / Backplate P4031 Ring Detect Relay (RDR)* P4032 Ring Detect Relay (RDR) / CE20 Line Powered Ringer / Backplate P4033 Headset (in lieu of Handset) P4034 Headset / CE20 Line Powered Ringer / Backplate P4035 Headset / Ring Detect Relay (RDR) P4037 Headset / Ring Detect Relay (RDR) / CE20 Line Powered Ringer / Backplate Options 22AC-401 22” (0.6m) Armored Handset Cord in Lieu of Standard Curly Cord 6m HC 20 ft (6m) Handset Cord - Field Replaceable Low Temperature Polymer Jacket P4042 Headset Kit (replaces handset) * Note: Telephone Requires External Signaling Device While the handset and fuse on the model EXT-401 is field replaceable, hazardous area equipment is not field serviceable. Please return equipment to the factory or an authorized depot for repairs. Distributed by: ENVIRONMENTAL Waterproof Enclosure Temperature Humidity Corrosion Resistant Industry Canada CSA & UL CSA Type 4 -40˚ to +140˚F ( -40˚ to +60˚C ) 0 - 95% RH Non-Condensing Epoxy Coated Circuit Boards ISO-9001:2008 Certification Today's Quality Creates Our Future Guardian pursues a policy of continuous improvement, therefore specifications are subject to change without notice. Calgary, Alberta, Canada Telephone: 403 258-3100 Facsimile: 403 253-4967 1-800-363-8010 (North America) [email protected] www.guardiantelecom.com EXT401 140918 Explosion Proof Ringers & Loudspeakers FEATURES and BENEFITS CE20 Ringer CE20 – Line Powered Explosion Proof Ringer • Sound pressure level at one meter, on axis – up to 75 dB without horn (Up to 90 dB with horn) • Threaded, weather proof enclosure • Projection horn • Copper-free aluminum body and cover • Sintered bronze flame arrestor SR40/SR60 – Explosion Proof Loudspeaker, Ringer, & Loudspeaker/Ringer CE20 Ringer with Horn • Mounting allows directional adjustments • Projection horn included • Powder coated cast aluminum enclosure • User selectable output power taps • Threaded end cap for easy installation APPLICATIONS These telephones are designed for use in locations with the highest hazardous area classifications such as: • Petroleum Refineries • Power Generation Facilities • Grain Handling Facilities • Bulk Fuel Loading Facilities • Paint or Solvent Manufacturing Plants • Munitions Storage and Production SR40/SR60 • Chemical Plants • Drilling Rigs • Gas Plants • Mines • Aerospace Sites and more . . . INSTALLATION and CONNECTABILITY CE20 – Line Powered Explosion Proof Ringer Guardian’s CE20 Explosion Proof Ringer is designed for use indoors and outdoors in hazardous areas where flammable gases, vapors or dust may be present. Guardian’s SR40 Explosion Proof unit can be set-up as a loudspeaker for paging applications, loud ringer to signal incoming phone calls, or both functions can be combined in one device. Guardian’s SR60 Explosion Proof unit is a high power paging loudspeaker. ISO-9001:2008 Certification Today's Quality Creates Our Future Guardian’s CE20 Explosion Proof Ringer utilizes telephone line power, and does not require a separate power source. Maintaining safety standards may require the use of special wiring conduits or other considerations. The CE20 can be ordered separately or as part of an integrated system. SR40/SR60 – Explosion Proof Loudspeaker, Ringer, & Loudspeaker/Ringer Guardian’s SR40 and SR60 Explosion Proof units generate up to 110 dB. The SR40 can be ordered in ringer configurations of 12/24 or 120/230 volts AC and as a combination ringer/loudspeaker. The SR60 is a 60 watt loudspeaker used in high powered applications. Maintaining safety standards may require the use of special wiring conduits or other considerations. 21-1 OVERALL DIMENSIONS & ENGINEERING SPECIFICATIONS  CE20  Line Powered Explosion Proof Ringer ENVIRONMENTAL 14.2” (360 mm) 6.1” (155 mm) 13.6” (345 mm) 5.4” (136 mm) Enclosure Type Temperature Humidity 5.0” (128 mm) 5.4” (136 mm) COMPLIANCE ELECTRICAL REQUIREMENTS - Line Powered Ringer Sensitivity Ringer Equivalence Number see "COMPLIANCE" below -40˚ to +140˚F ( -40˚ to +60˚C ) 0 - 95% RH Non-Condensing 40 -100 V, 16 - 25 Hz 04.A/0.8B ELECTRICAL PERFORMANCE CE20 Line Powered Ringer c/w Projection Horn CE20 Line Powered Ringer w/o Projection Horn CE20 c/w Projection Horn − P7021 CSA 158194 Class 1, Division 1 Groups B, C, & D; Class l, Zone 1, Group llB +H2; Type 4X Class ll Division 1, Groups E, F & G; Class lll; T5 CE20 w/o Projection Horn − P7020 CSA 158194 Class 1, Division 1 Groups B, C, & D; Class l, Zone 1, Group llB +H2; Class ll Division 2, Groups F & G; Class lll; T5 UL File #: E214408 Class 1, Division 1 Groups B, C, & D; Class l, Zone 1, Group llB +H2; Type 4X UL File #: E214408 Class 1, Division 1 Groups B, C, & D; Class l, Zone 1, Group llB +H2; 90 +/- 3 dB 75 +/- 3 dB MECHANICAL SPECIFICATIONS Body Construction Copper Free Cast Aluminum Cover and Base With Epoxy Powder Coat Flame Arrestor Sintered Bronze W/O Projection Horn Net Weight 3.5 lbs ( 1.6 kg ) Shipping Weight 4.0 lbs ( 1.68 kg ) Shipping Dimensions ( L x W x D ) 9.0” x 6.0” x 5.5“ ( 229 x 153 x 140 mm ) C/W Projection Horn Net Weight 6.0 lbs ( 2.7 kg ) Shipping Weight 7.5 lbs ( 3.4 kg ) Shipping Dimensions ( L x W x D ) 16.0” x 10.5” x 9.5“ ( 407 x 267 x 242 mm ) ORDERING INFORMATION Warranty: One year parts and labor Order No. Description P7020 CE20 Line Powered Ringer P7021 CE20 Line Powered Ringer c/w Projection Horn OVERALL DIMENSIONS & ENGINEERING SPECIFICATIONS  SR40/60 Explosion Proof Speaker, Ringer, Speaker/Ringer 6.1” (155 mm) 14.2” (360 mm) ELECTRICAL Input Voltage/fuse Rating Duty Cycle 8.3” (210 mm) 17.7” (448 mm) Enclosure Type Temperature Humidity Dust Resistant 20.2” (513 mm) 8.9” (226 mm) ENVIRONMENTAL 8.3” (210 mm) PERFORMANCE AS A SPEAKER 250 - 7500 Hz SR40 70V 30 W max SR40 70V and ringer 15 W max SR40 16 Ohm 40 W max SR60 70V 60 W max SR60 16 Ohm 60 W max 110 dB at 1.0 meter max MECHANICAL SPECIFICATIONS Body Construction Flame Arrestor Projection Horn Net Weight Shipping Weight Shipping Dimensions ( L x W x D ) 21-2 see "COMPLIANCE" below -40˚ to +140˚F ( -40˚ to +60˚C ) 0 - 95% RH Non-Condensing Gasketted & Threaded Joints COMPLIANCE 10.2” (258 mm) Frequency Response Power Rating Sound pressure level (SPL) 12VAC/1A, 24VAC/.75A, 120VAC/.5A or 230VAC/.25A 50% Copper Free Cast Aluminum And Powder Coated Sintered Bronze ABS 20.0 lbs ( 9.0 kg ) 22.0 lbs ( 10.0 kg ) 12.0” x 12.0” x 16.0“ ( 305 x 305 x 407 mm ) ISO-9001:2008 Certification Today's Quality Creates Our Future CSA LR 65547-27 Class 1, Division 1 Groups B, C, & D; Class l, Zone 1, Group llB +H2; Type 3R Class ll Division 1, Groups E, F & G; Class lll Temp Code: T5 for SR40 Models Temp Code: T3C for SR60 Models ORDERING INFORMATION Order No. P7240 P7241 P7243 P7244 P7245 P7246 P7247 P7248 P7249 P7250 P7251 P7260 P7262 UL E165888 Class 1, Division 1 Groups B, C, & D; Class l, Zone 1, Group llB +H2; Type 4X T6 (Exception T4 on 120 VAC & 230 VAC Models) TAMB: -40˚ to +104˚F ( -40˚ to +40˚C ) Warranty: One year parts and labor Description SR40, 24 VAC, Ringer SR40, 24 VAC, 15 Watt Paging Loudspeaker/Ringer SR40, 230 VAC, Ringer SR40, 230 VAC, 15 Watt Paging Loudspeaker/Ringer SR40, 30 Watt 70V Paging Loudspeaker SR40, 30 Watt, 70V Paging Loudspeaker with DC Filter Circuit for monitoring line integrity SR40, 30 Watt, 16 Ohm Paging Loudspeaker SR40, 12 VAC, Ringer SR40, 12 VAC, 15 Watt Paging Loudspeaker/Ringer SR40, 120 VAC, Ringer SR40, 120 VAC, 15 Watt Paging Loudspeaker/Ringer SR60, 60 watt, 70V Paging Loudspeaker SR60, 60 watt, 16 Ohm Paging Loudspeaker Distributed by: Calgary, Alberta, Canada 1-800-363-8010 (North America) Tel: 403 258-3100 Fax: 403 253-4967 [email protected] www.guardiantelecom.com Guardian pursues a policy of continuous improvement, therefore specifications are subject to change without notice. ExpRS 140919 HSK-EXT-401 Intrinsically Safe EXT-401 Headset Kit HS-EXT-401 Intrinsically Safe EXT-401 Headset FEATURES and BENEFITS • Field replacement for standard handset on EXT-401 telephone • UL listed − for use with EXT-401 Explosion proof telephone only • 20’ (9.5m) cord allows mobility for the user • Provides clear communication in noisy environments • Noise canceling microphone • Behind-the-head dual ear for use with a safety cap or helmet microphone boom • Adjustable Velcro strap HS-EXT-401 Headset (P7221) with Talk/Mute control and belt clip on the cord APPLICATIONS The HSK-EXT-401 Headset and Headset Kit are designed for use with Guardian’s EXT-401 in locations with the highest hazardous area classifications such as: GUARDIAN TELECOM INC. TELEPHONE FOR USE IN HAZARDOUS LOCATIONS CLASS I GROUPS B, C, & D CLASS I ZONE 1, GROUPS IIB+H2 CLASS II GROUPS E, F, & G ENCLOSURE TYPE 4 RECEPTACLE PROVIDES INTRINSICALLY SAFE OUTPUT USE ONLY MODEL 301SC OR 301SCPB HANDSET WITH THIS TELEPHONE [Exia] Associated equipment Appareillage Connexe LISTED US C 158194 13X8 RELAY CONTACTS 10A 1/3HP 240V AC 10A 1/3HP 120V AC 10A 30V DC FUSE: 0.25A 48VDC - TYPE 2AG, FAST-ACTING SER. NO. CAT. NO.: 401 (TA LK ) REFER TO USER GUIDE FOR INSTALLATION MADE IN CANADA (M UT E) The rugged and reliable HS-EXT-401 Headset and the HSK-EXT-401 Headset Kit (P4042) are field replacement for the standard handset on an EXT-401 phone providing clear communication in noisy and hazardous area environments. The 20’ (9.5m) cord allows mobility for user. The kit includes headset assembly, hanger complete with hook switch magnet and headset hanger bracket. 1 ABC 8 DEF GHI 4 5 JKL MNO PRS TUV WXY 7 8  0 OPER LINK RLS 3 6 9 # REDIAL WARNING FIELD REPAIR NOT POSSIBLE. FOR SERVICE RETURN TO FACTORY. TO PREVENT IGNITION OF HAZARDOUS ATMOSPHERE, DISCONNECT FROM THE SUPPLY CIRCUIT BEFORE OPENING OR REPLACING FUSE. KEEP TIGHTLY CLOSED WHEN CIRCUITS KEEP TIGHTLY CLOSED WHEN CIRCUITS ARE ALIVE. ALL CONDUIT RUNS MUST BE SEALED WITHIN 18 INCHES (450 mm) OF THIS ENCLOSURE. BREAKING OF REAR BOLT SEALS VOIDS MANUFACTURER'S WARRANTY. SUBSTITUTION OF COMPONENTS M AY IMPAIR INTRINSIC SAFETY. ATTENTION CET APPAREIL NE PEUT ETRE REPARE A PIED D'OEUVRE. NE PAS L'OUVRIR LES BOULONS DOIVENT ETRE BIEN SERRES; EN CAS DE REMPLACEMENT DE LE PLOMB, LE TELEPHONE FAUT ETRE DEBRANCHE; RETOURNER L'APPAREIL A L'USINE POUR LE DEPANNAGE; FAIT DE BRISER LE SCEAU DU FABRICANT A L'ARRIERE DE L'APPAREIL ANNUELE LA GUARANTIE DU FABRICANT. • Chemical Plants • Petrochemical Plants • Offshore Drilling Rigs • Missile Silos • Gas Plants • Refineries • Fueling Stations • Bulk Loading Stations • Fertilizer Plants and more . . . • Defense & Aero-Space Installations • Munitions Storage Depots • Land-based Drilling Rigs • Liquefied Natural Gas Terminals • Tankers and Tanker Depots • Oil & Gas Metering Facilities • Paint & Varnish Manufacturing Plants • Grain Processing & Similar Industries • Breweries and Distilleries Industry Canada Industrie Canada 1012 4339 A INSTALLATION and CONNECTABILITY Comes with an adapter to connect to the EXT-401 or other compatible devices. Instructions for removing the original handset and installing the Headset Kit are included. ORDERING INFORMATION Warranty: One year parts and labor Order Number Description P4042 HSK-EXT-401 Intrinsically Safe EXT-401 Headset & Hanger Kit P7221 HS-EXT-401 Intrinsically Safe EXT-401 Headset Distributed by: ISO-9001:2008 Certification Today's Quality Creates Our Future ISO-9001:2008 Certification Today's Quality Creates Our Future Guardian pursues a policy of continuous improvement, therefore specifications are subject to change without notice. Calgary, Alberta, Canada Telephone: 403 258-3100 Facsimile: 403 253-4967 1-800-363-8010 (North America) [email protected] www.guardiantelecom.com HSKEXT401 140919 25-11 25-12 Sections Guardian Telecom’s Product and Services Guide Catalogue is a compilation of individual Category Section Publications Guardian 1  About Guardian Telecom • Building on a Legacy of Design and Service • Communications: Easy, Reliable and Safe • More Choices, Selections and Services • Standard Features • Options & Accessories • Product and Project Consultation • Commissioning Services • Sound Studies • Training • Maintenance, Cleaning, Trouble Shooting & Refurbishment • Custom Design • Page/Talk, Telephone, PA/GA and Talk/Back Systems • Standards and Classifications  Knowledge Base  Glossary Page/Talk Explosion Proof 13 Stations 14 System Cable 15 System Components 16 Page Station Module Replacements Products Page/Party®  Module Replacements 1 17 Page/Talk Module Replacements 17 Talk/Back Analog Telephones Explosion Proof 2 Explosion Proof Amplifier 18 ATEX-IEC Multi-Channel Amplifiers 18 3 Hazardous Area 4 Outdoor Industrial 5 PA/GA Indoor Industrial System Components 19 Acoustic Booths Aluminum & GRP 6 Emergency/Help Point 7 Correctional 8 20 Loudspeakers/Ringers Explosion Proof 21 Hazardous Area 22 ATEX-IEC 23 General Area 24 VoIP Telephones Hazardous Area VoIP 9 Outdoor Industrial VoIP 10 Indoor Industrial VoIP 11 Emergency/ Help Point VoIP 12 Guardian represents DNH, E2S, Federal Signal, MEDC and TOA, and has access to an extensive range of other world class leading manufacturers. Visit www.guardiantelecom.com for additional information on Explosion Proof, Hazardous Area, ATEX-IEC and General Area Loudspeakers & Ringers. Accessories & Enclosures Telephone Accessories & Enclosures 25 Page/Talk Accessories 26 Product Index 1 Page/Party® is a registered trademark of GAI-Tronics Inc. Use does not imply endorsement. Guardian Telecom Part No., Description, Product Section & Product Data Sheet Product and Services Guide — Table of Contents www.guardiantelecom.com 27 PSG-8.2.3D Calgary, Alberta, Canada Telephone: 403 258-3100 Facsimile: 403 253-4967 1-800-363-8010 (North America) [email protected] All content including the "Guardian Telecom" logo, images, graphics and descriptions are not to be used without the expressed written authorization of Guardian Telecom Inc., Calgary, Alberta, Canada. All other names and logos are the trademarks or registered trademarks of their respective companies. Guardian pursues a policy of continuous improvement, therefore product, content and specifications are subject to change without notice. Design, specifications and release dates are subject t o change without notice. Canada USA Middle East Guardian Telecom Product and Services Guide www.guardiantelecom.com PSG-8.2.3D