Preview only show first 10 pages with watermark. For full document please download

Express5800/e110b Express5800/e110b-m System Configuration Guide Contents:

   EMBED


Share

Transcript

Express5800 Servers Express5800/E110b Express5800/E110b-M System Configuration Guide 4th Edition, April 2011 Contents: Introduction Specification External view Outline drawing / Images Tested operating system list Configuration diagram System configuration steps overview Quick configuration diagram System Configuration E110b-M servers 1. Basic system 2. Processor 3. Memory 4. Internal drive 5. Keyboard 6. Mouse 7. Optical disk drive 8. Floppy disk drive 9. System management Server chassis 1. Consolidated PSU 2. Server chassis 3. Cooling fan box 4. Blank Panel 5. Cable Management kit 6. DC power cable Consolidated PSU 1. Consolidated PSU 2. Power supply module 3. Unit Management Supplementary Notes System Configuration Guide Express5800/E110b-M Introduction The document contains product and configuration information that enable you to configure your system. The proper configuration of your system will be configured by following the step to select the components. The section to select the components mostly consists of two part, configuration information, selectable peripherals list. Then please select configuration firstly and select necessary peripherals. Sample of section to select component: 4. Internal drive(HDD / SSD) [std. 0 / max. 1] Configuration information  Integrated SATA controller  3Gb/s SATA Standard  Internal SAS/SATA cable [K410-XXXXXX] XXXXXX] (non hot plug) SATA HDD SATA SSD  NOTE  SAS hard drive is not supported in the system. Supported SATA HDD, SATA SSD Selectable peripherals list SATA HDD (2.5-inch, 3Gb/s)  XXX GB HDD 7,200rpm [NXXXX-XXX]  YYY GB HDD 7,200rpm [NXXXX-XXX] SATA SSD (2.5-inch, 3Gb/s)  XX GB SSD [NXXXX-XXX] About icons: • • The icons on the configuration chart stand for the supporting OS as showing in the following table. For the request to use Linux OS, please also refer to the website http://www.nec.com/global/prod/express/linux/index.html … Supported by NEC … Certified by Distributor 2003 : Windows Server 2003 (with SP1 or later) 2003x64 : Windows Server 2003, x64 Edition 2003R2 : Windows Server 2003 R2 2003 R2x64 : Windows Server 2003 R2, x64 Edition 2008 EL4x64 EL5 EL5x64 : Windows Server 2008 2008x64 : Windows Server 2008 (x64) 2008 R2 : Windows Server 2008 R2 (x64) ESXi4 : VMware ESXi 4 SL10 : SUSE Linux Enterprise Server 10 SL10x64 EL4 ML4 ML4x64 AXS3 AXS3x64 : Red Hat Enterprise Linux ES4/AS4 : Red Hat Enterprise Linux ES4(EM64T)/AS4(EM64T) : Red Hat Enterprise Linux 5/AP5 : Red Hat Enterprise Linux 5(EM64T)/AP5(EM64T) : MIRACLE LINUX V4.0 : MIRACLE LINUX V4.0(EM64T) : Asianux Server 3 : Asianux Server 3(EM64T) : SUSE Linux Enterprise Server 10(EM64T) NEC Corporation 4th Edition, April 2011 2 System Configuration Guide Express5800/E110b-M Specification (Express5800/E110b-M) (Express5800/E110b  Outline  The low-power 1-socket server optimized for high density mounting  Features    Achieves low power consumption with Intel® Atom™ Atom Processor N450. Supports one 2.5-inch SATA and SDD Equips EXPRESSSCOPE Engine 2 to enable superior system management Model Product Code Type Clock Speed Processor Number of processors (std./max.) L2 Cache (per core) Core and Thread (per processor) I/O Controller Hub (IOH) Capacity (std./max.) Supported Memory Native Speed (max.) Memory Error detection and correction Memory sparing Memory mirroing Capacity (std.) Hard Capacity (max.) drive Hot swap Storage Controller type and supported RAID level Expansion Graphics Optical disk drive Floppy disk drive Media bay Type Controller/Video RAM Color depth and Resolution Interface Dimensions (W x D x H) Weight(min./max.) *3 Power consumption (DC12V, Max. config, Idle) Power consumption (DC12V, Max. config, Operating) Power consumption (AC power supply, Operating) Temperature, Relative Humidity Included Accessories Supported operating Certified by ISV *4 system Tested operating system *4 Express5800/E110b-M N8100-1635F Intel® Atom™ Processor N450 1.66GHz 1/1 512KB 1C/2T Intel® 82801HBM chipset 0 GB/2GB (2x 1GB) DDR2-667 SO-DIMM 667MHz 2.5-inchHDD: SATA 1TB (1x 1TB) 2.5-inchSSD: SATA 100GB (1x 100GB) Not supported SATA 3Gb/s: No RAID feature External drive (Optional)*1 Optional: Flash FDD (1.44MB)*2 Integrated in Server Management Controller/32MB 16.7M color: 640x480, 800x600, 1, 024x768, 1, 280x1, 024 1x SUV (1x Seial B, 2x USB 2.0, 1x VGA) 22.1 x 453.5 x 119.4 mm 0.7kg/1.0kg 23.3 W 27.0 W 2091VA/2063W (System, max) Operating: 10 to 40°C/Non-Operating: -10 to 55°C, 20 to 80%(non condensation) Getting started Red Hat Enterprise Linux 4.8 or later, Red Hat Enterprise Linux 4.8 (EM64T) or later Red Hat Enterprise Linux 5.4 or later, Red Hat Enterprise Linux 5.4 (EM64T) or later Refer to "Linux on NEC Express5800" on NEC global site Note: *1 Arrange an External DVD for maintenance and OS installation purpose. *2 Arrange Flash FDD if needed. For intended uses, refer to the Flash FDD Supplementary Notes in this guide. *3 Minimum configuration: 1x 1GB DIMM and no HDD or SSD, Maximum configuration: 2x 2GB DIMM, 1x 500GB HDD *4 Refer to Linux on NEC Express5800 on NEC global site for the latest information. NEC Corporation 4th Edition, April 2011 3 System Configuration Guide Express5800/E110b-M Specification (Server chassis)  Outline  The server chassis employing up to 20 E110b-M M server  Features     Up to 20 E110b-M M servers can be installed in 3U height. Supports hot plug replacement for servers Supports hot plug-able able redundant fan to enable to replace it without interruption to the system Power supplying from consolidated power supply unit Product name Product code Number of sever slots Server chassis N8141-49F 20 40x 1000BASE-T LAN connector (1000BASE-T/100BASE-TX/10BASE-T, RJ-45, 40x Back, 2 port per server) 1x Management LAN connector (100BASE-TX/10BASE-T, RJ-45, 1x Back, shared w ith 20 server) Interface Cooling Fan Power connector Chassis formfactor Dimensions(W x D x H) Weight(min./max.) *1 Power consumption(12VDC, min./max.) *1 Power consumption(100VAC, Operating) Temperature , Relative Humidity Included Accessories Redundant Fan supported, Hot plug Up to 10 servers: standard / 11 to 20 servers : optional 1x Propriety 12VDC connector 3U rackmount 444.0 x 701.5 x 130.0 mm (Excluding inner rail), 466.0 x 724.5 x 130.0 mm (Including inner rail) 22kg / 42kg 52W / 610W 2091VA / 2063W Operating: 10 to 40°C/Non-Operating: -10 to 55°C, 20 to 80%(non condensation) EXPRESSBUILDER (NEC ESMPRO Manager, Users guide(PDF)), SUV cable(0.3m),Tool-less slide rail kit Note: *1 Minimum configuration: No servers and no optional fan box, Maximum configuration: 20 serves and 2 optional fan box included Specification (Consolidated Consolidated PSU) PSU  Outline  The power supply unit providing electrical power to many servers.  Features     Equips high efficient 80 PLUS® Gold power supply module. Supports up to 4 power module with hot plug and redundant feature Enables to supply electrical power for 80 servers per 1 consolidated power supply unit Enables to manage the consolidated power supply unit from remote site. Product name Product code Power bay N8142-36F 1x Serial(RS-232C, 9-pin mini-Dsub, Port B, 1x Front), 1x VGA (15-pin mini-Dsub, 1x Front) 2x USB2.0 (2x Front), 1x Management LAN connector (100BASE-TX/10BASE-T, RJ-45) Interface Power supply Input(AC) Number of Power module Redundant PSU Type Output(DC) Pow er connector Max. output Power consumption(100VAC, Operating) Cooling Fan Power connector Chassis formfactor Dimensions(W x D x H) Weight(min./max.) *1 Temperature , Relative Humidity Included Accessories Standard : 2 / Max : 4 Supported (needed more than 2 power modules, hot plug) 650W 80 PLUS® Gold Power supply (hot plug) 100-240 VAC±10%,50/60Hz±3Hz 4x Propriety 12VDC connector 1,700W *2 2091VA / 2063W Redundant Fan supported, Hot plug Up to 10 servers: standard / 11 to 20 servers : optional 4x Propriety 12VDC connector 1U rackmount 444.0 x 671.0 x 43.5 mm (Excluding inner rail), 465.6 x 718.0 x 43.5 mm (Including inner rail) 13kg / 15kg Operating: 10 to 40°C/Non-Operating: -10 to 55°C, 20 to 80%(non condensation) Getting started,Tool-less slide rail kit Note: *1 Minimum configuration: 2 power module, Maximum configuration: configuration 4 power module *2 The maximum output per 1 DC connector can not exceed 840W. 840 NEC Corporation 4th Edition, April 2011 4 System Configuration Guide Express5800/E110b-M External view (Express5800/E110b-M) (Express5800/E110b Front view Power On/ Standby switch Power LED HDD access LED DUMP(NMI) switch Status LED UID(Unit ID) LED UID(Unit ID) switch SUV connector Lever Pull-out tab NEC Corporation 4th Edition, April 2011 5 System Configuration Guide Express5800/E110b-M External view (Server chassis) Front view Server slots Pull-out tab Rear view Fax box slots Management LAN port DC 12V input connector LAN port A for servers LAN port B for servers NEC Corporation 4th Edition, April 2011 6 System Configuration Guide Express5800/E110b-M External view (Consolidated PSU) Front view Pull-out tab Serial connector (Port B) Power button UID(Unit ID) LED Power LED STATUS LED UID(Unit ID) button USB connector VGA connector Maintenance LED Maintenance button Rear view Power supply module bay UID(Unit ID) button DC output connector UID(Unit ID) LED Pull-out tab Management LAN connector DC output button DC output LED NEC Corporation 4th Edition, April 2011 7 System Configuration Guide Express5800/E110b-M Outline drawing / Images (E110b-M) (E110b Rear Front 119.4 mm Outline drawing 19.5 mm 22.1 mm 441.2 mm 453.5 mm Image (Interior view) NEC Corporation 4th Edition, April 2011 8 System Configuration Guide Express5800/E110b-M Outline drawing / Images (Server chassis) Rear 444.0 mm 466.0 mm Front Outline drawing 701.5 mm 130.0 mm 724.5 mm Images - Front view - Rear view NEC Corporation 4th Edition, April 2011 9 System Configuration Guide Express5800/E110b-M Outline drawing / Images (Consolidated PSU) Rear Front 465.6 mm 444.0 mm Outline drawing 671.0 mm 43.5 mm 718.0 mm Images - Front view - Rear view NEC Corporation 4th Edition, April 2011 10 System Configuration Guide Express5800/E110b-M Tested operating system list (as of January 2011) Operating system Red Hat Enterprise Linux 4.8 Red Hat Enterprise Linux 4.8 (EM64T) Red Hat Enterprise Linux 5.5 Red Hat Enterprise Linux 5.5 (EM64T) CentOS 4.8 (x86) CentOS 4.8 (x86_64) CentOS 5.5 (x86) CentOS 5.5 (x86_64) Debian GNU/Linux 5.0 (x86) Debian GNU/Linux 5.0 (AMD64) SUSE Linux Enterprise Server 10 SP3 (x86) SUSE Linux Enterprise Server 10 SP3 (x86_64) SUSE Linux Enterprise Server 11 (x86) SUSE Linux Enterprise Server 11 (x86_64) Vine Linux 5.1 (x86) Vine Linux 5.1 (x86_64) Turbolinux 11 Server SP1 (32-bit) FreeBSD 7.3 (i386) FreeBSD 7.3 (amd64) FreeBSD 8.0 (i386) FreeBSD 8.0 (amd64) Fedora 13 (x86) Fedora 13 (x86_64) Tested X X X X X X X X X X X X X X X X X X X X X X X Note: Refer to "Linux on NEC Express5800" on NEC global site for the latest information. http://www.nec.com/global/prod/express/linux/ NEC Corporation 4th Edition, April 2011 11 System Configuration Guide Express5800/E110b-M System configuration steps overview 2. Server chassis 1. Server 3. Power unit Power cords DC power cable Up to 20 servers Express5800/E110b-M [N8100-1635F]      Server chassis [N8141 [N8141-49] Consolidated PSU [N8142-36F] Up to 20 Express5800/E110b-M servers can be installed into one server chassis. Up to 240 servers can be installed into one 42U rack frame in the power loading of 6 kVA per rack. The power electricity for 80 or less servers can be supplied by one Consolidated PSU with 4 power supply modules. The number of the server that can be installed in one rack depends on the system configuration. Refer to the server installation guideline in the guide. Quick configuration diagram Server chassis 1x DC-in Conn. Server or Blank panel 1x Manage ment LAN DC power cable Server slots (max.20) 40x LAN (*1) Fan box 1 - 10 servers:: Standard 11 - 20 servers: Optional Server 1x HDD Bay Proc. (Atom) 2x DIMM slots *1 2 port / server Power unit 4x DC-out Conn. Power supply module Power supply module 2.5-inch HD bay 2.5-inchSATA HDD 2.5-inchSATA SSD NEC Corporation DIMM slots 1GB memory (DDR2-667) (max.2GB) Power supply module Power supply Std.2, Max.4 Power supply module 4th Edition, April 2011 12 System Configuration Guide Express5800/E110b-M System configuration (E110b-M) (E110b 1. Basic system Product Code N8100-1635F EL4 EL4x64 EL5 Product Name Basic Configuration Express5800/E110b-M (1C/N450) 1x Atom N450 (1.66GHz, 1 core/2 thread) no no-DIMM, no-HDD SUV cable EL5x64  NOTE  To connect input devices and optical drive with server, use the SUV(Serial/USB/Video) cable attached with server chassis. 2x USB2.0 1x Serial 1x VGA 2. Processor [std. 1]  Intel® Atom™ Processor N450, 1.66GHz, 1 core/ 2 thread Standard 3. Memory [std. 0 / max. 2] DDR2-667 (PC2-5300) non-ECC, Unbuffered  1GB memory(1x 1GB) [N8102-370]  NOTE  At least one DIMM is required to order to configure the system. 4. Internal drive(HDD / SSD) [std. 0 / max. 1] (non hot plug)  Integrated SATA controller  3Gb/s SATA Standard  Internal SAS/SATA cable [K410-223(00)] 223(00)] SATA HDD SATA SSD  NOTE  SAS hard drive is not supported in the system. Supported SATA HDD, SATA SSD SATA HDD (2.5-inch, 3Gb/s)  160GB HDD 7,200rpm  500GB HDD 7,200rpm  1TB HDD 7,200prm SATA SSD (2.5-inch, 3Gb/s)  100GB SSD NEC Corporation [N8150-316] [N8150-317] [N8150-335] [N8150-708] 4th Edition, April 2011 13 System Configuration Guide Express5800/E110b-M System configuration (E110b-M) (E110b 5. Keyboard  104 Keyboard  USB [N8170-25] 6. Mouse  USB Optical Mouse [N8170-22]  USB, 2-button, Optical with wheel 7. Optical disk drive  External DVD-ROM(USB) [N8160-85] 2003R2 2003 R2x64 2008 2008x64 EL4 EL4x64 EL5 EL5x64 2008 R2 NOTE:  Optical drive is required for installation of operating system and system maintenance. 8. Flash FDD (connect to USB port)  Flash FDD  Capacity:1.44MB [N8160-86] NOTE:  FDD is NOT included as standard. Arrange Flash FDD if needed. For intended uses, refer to the Flash FDD Supplementary Notes in this guide.  Flash FDD [N8160-86] can not be shipped to Taiwan/Korea. Taiwan/Korea NEC Corporation 4th Edition, April 2011 14 System Configuration Guide Express5800/E110b-M System configuration (E110b-M) (E110b 9. Server Management (BMC, EXPRESSSCOPE Engine 2)  EXPRESSSCOPE Engine 2  1x Management LAN (100BASE-TX, 10BASE-T) Standard Option  Remote KVM and Media License [N8115-03]  License for one server  Remote console and remote media are enabled regardless of OS status.  Remote console  Displays a graphics console on the web browser of remote terminal (PC/server)  Controls keyboard and mouse via the remote terminals' web browser  Remote media  Provides access to the CD/DVD/FD/Flash memory on the remote terminals (PC/server) as if the user were accessing the drives locally  Functions  The functions are enabled regardless of OS status and operating condition. (with some exceptions) Monitoring server Stall monitoring/ automatic reboot Alerting Remote console (via LAN) Remote control (via LAN) Maintenance Others Remote Wake Up Group management Industry Standard E110b-M EXPRESS SCOPE Engine 2 (Standard) EXPRESSSCOPE Engine 2 with Remote KVM and Media License Monitoring temperature /fan/voltage X X Collecting hardware event log X X POST/BIOSStall monitoring X X X X X X X X *1 X *1 X X X X X X X X X X 2.0 X X X X X X X X X X X X X X X 2.0 HW failure, Boot failure and OS panic (by SNMP,E-Mail via LAN) HW failure, Boot failure and OS panic (via COM port (modem)) POST/BIOS setup, DOS utility*2 Boot screen, Panic screen *2 CUI screen(OS console) *2 GUI screen(OS console) Remote reset /power on–off /dump *2 * OS shutdown Remote media (CD/DVD, FD, Flash)(via LAN) CLP (Command Line Protocol, DMTF compliant) Remote control via web browser(via LAN) Remote batch Scheduling Remote boot (PXE boot), maintenance utility Automatic IP address setting via DNS/DHCP Wake On LAN, Wake On Ring Monitoring/controlling by the group IPMI (version) *1 Linux uses serial console. The standard serial port bus is used when using via LAN. *2 Available to manage via serial port  NOTE  When using H/W remote KVM console function the display is in 65,536 colors with resolution of 1280x1024.  For details on OS support and recommended browser of Remote terminal, and other functions, refer to the "EXPRESSSCOPE Engine 2 Users Guide”. NEC Corporation 4th Edition, April 2011 15 System Configuration Guide Express5800/E110b-M System configuration (Server chassis) 1. Server chassis Product Code N8141-49F Product Name Server chassis Basic Configuration  2 power supply modules  2 cooling fan box as standard for cooling up to 10 serves  1 SUV cable  No DC power cables, No blank panel 2. Cooling fan box[std. 1 / max. 2]  Additional FAN Box [N8181-75]  NOTE  The fan boxes for cooling 10 E110b-M servers are installed as standard. .  1 additional FAN box need to be ordered if more than 11 servers are installed into one chassis. chassis.  Supports hot plug feature and redundant configuration 3. Blank panel  Blank Panel [N8141-50]  NOTE  No blank panel is included in server chassis.  Please be sure to order blank panels of the number of slots in which the server is not installed. 4. Cable Management Kit  Cable Management Kit for rear (600mm/700mm width rack)  Cable Management Kt for front (700mm width rack) [N8141-53] [N8141-54]  NOTE  The kit is used for the cable management of LAN cables and power cords connected to the rear of the server chassis. The kit includes tray and guide rail to fix the cables.  To order the kit is recommended for suitable cable management. management  The kit to be ordered depends on the width of 19-inch rack frame. Guide rail Tray 5. DC power cable  DC power cable (60cm)  DC power cable (90cm) [K410-213(0A)] [K410-213(0B)] DC power cable  NOTE  The power cable is used for connecting server chassis and Consolidated PSU.  Please be sure to order the cable of enough length to connect server chassis and Consolidated PSU. NEC Corporation 4th Edition, April 2011 16 System Configuration Guide Express5800/E110b-M System configuration (Consolidated PSU) 1. Consolidated PSU Product Code Product Name N8142-36F Consolidated PSU Description  Consolidated power supply unit(1U)  Equips high conversion efficiency power supply certified with 80 PLUS® Gold, and 2 power supply modules are standard for redundant configuration.(Max.4, hot plug supported)  Enables server management from remote site by server management controller.  Equips 4 DC output connectors and up to 4 server chassis can be connected in 1 server chassis. 2. Power supply modules [std. 2 / max. 4] 4  Power supply module [N8181-76F] 76F] Power cord Std. 2 Max.4  NOTE  2 power supply modules are standard for redundant configuration. Up to 4 power supply modules can be installed into 1 Consolidated PSU. Hot plug supported. supported  . The number of power supply modules required depends on the number of the servers and the number of the chassis installed. Refer the table of Total power consumption and weight estimation NEC Corporation 4th Edition, April 2011 17 System Configuration Guide Express5800/E110b-M System configuration (Consolidated PSU) 3. Unit management (BMC, EXPRESSSCOPE Engine 2)  EXPRESSSCOPE Engine 2  1x Management LAN (100BASE-TX, 10BASE-T) Standard  Functions  The functions are enabled regardless of operating condition. Consolidated PSU EXPRESSSCOPE Engine 2 (Standard) Managing unit Stall monitoring/ automatic reboot Alerting Monitoring temperature /fan/voltage/power consumption X Collecting hardware event log X POST/BIOS Stall monitoring X HW failure, Boot failure (by SNMP,E-Mail via LAN) X HW failure, Boot failure (via COM port (modem)) X X *1 X *1 X *2 X Remote console (via LAN) POST/BIOS setup, DOS utility*3 Boot screen *3 Remote reset /power on–off off of manament controller*3 CLP (Command Line Protocol, DMTF compliant) Remote control (via LAN) Remote control via web browser(via LAN) X Remote batch X Scheduling - Maintenance Maintenance utility - Others Automatic IP address setting via DNS/DHCP X Group management Monitoring/controlling by the group X Industry Standard IPMI (version) 2.0 *1 The remote console feature is supported on the management controller installed in the Consolidated PSU. *2 The remote power on feature is for managing the power of management controller. The management controller need not always power on. To power on the management controller is required for setting or maintaining the Consolidated PSU. *3 Available to manage via serial port  NOTE  Remote KVM and Media License is not supported in EXPRESSSCOPE Engine 2 of Consolidated PSU. Management controller  Management controller  The Consolidated PSU equips the management controller as standard feature to monitoring the unit from remote site.  Most functions listed above can be supported if the management controller is powered off.  To power on the management controller is required for setting or maintaining the Consolidated PSU. Consolidated PSU NEC Corporation 4th Edition, April 2011 18 System Configuration Guide Express5800/E110b-M System configuration (Consolidated PSU) Total power consumption and weight estimation  Please consult our sales representative if another estimation is needed.  Total weigh indicates a total value of the weight of the following components: • E110b-M M server, Sever chassis(including rail kit), Consolidated PSU(including rail kit), blank panel, cable management kit(rear)) , fan box, power supply modules, power cords, DC power cords Total weight and power consumption based on 20 E110b--M servers, 1 server chassis and 1 Consolidated PSU: AtomN450 AtomN450 AtomN450 AtomN450 AtomN450 AtomN450 System configuration of 1GB memory 2GB memory 1GB memory 2GB memory 1GB memory 2GB memory E110b-M no-HDD SSD no-HDD SSD HDD HDD 53kg 53kg 53kg 53kg Total Weight 49kg 50kg Number of power 2 2 2 2 Supply module 2 2 (std.2/max.4) 597W 657W 508W 567W W 508W 567W Maximum power 609VA 670VA 519VA 579VA consumption VA 519VA 579VA (100 VAC) 6.1A 6.7A 5.2A 5.8A A 5.2A 5.8A Total weight and power consumption based on 40 E110b--M servers, 2 server chassis and 1 Consolidated PSU: AtomN450 AtomN450 AtomN450 AtomN450 AtomN450 AtomN450 System configuration of 1GB memory 2GB memory 1GB memory 2GB memory 1GB memory 2GB memory E110b-M no-HDD no-HDD HDD HDD SSD SSD Total Weight 88kg 88kg 96kg 96kg 96kg 96kg Number of power Supply module 3 3 3 3 3 3 (std.2/max.4) W 985W 1104W 1163W 1282W 985W 1104W Maximum power consumption VA 1005VA 1126VA 1187VA 1308VA 1005VA 1126VA (100 VAC) A 10.1A 11.3A 11.9A 13.1A 10.1A 11.3A Number of E110b-M M server that can be installed in one Consolidated PSU configuration: AtomN450 AtomN450 AtomN450 AtomN450 AtomN450 AtomN450 System configuration of 1GB memory 2GB memory 1GB memory 2GB memory 1GB memory 2GB memory E110b-M HDD HDD SSD SSD no-HDD no-HDD Number of servers 80 74 70 63 80 74 Total Weight Number of power Supply module (std.2/max.4) 163kg 161kg 170kg 165kg 179kg 175kg 4 4 4 4 4 4 1938W 1978VA 19.8A 2041W 2082VA 20.8A 2031W 2072VA 20.7A 2050W 2092VA 20.9A 1938W 1978VA 19.8A 2041W 2082VA 20.8A Maximum power consumption (100 VAC) NEC Corporation W VA A 4th Edition, April 2011 19 System Configuration Guide Express5800/E110b-M Supplementary Notes  Hard disk  Measurement units of the hard disk capacity are 1GB=10003B and 1TB=10004B. The capacity is less when compared with same capacity figures based on 1GB=10243B and 1TB=10244B.  System Clock  When stored at a low or high temperature, the system clock may largely deviate from the current time. Use NTP client service to keep computer clock accurate.  EXPRESSBUILDER   EXPRESSBUILDER (DVD media) includes the following:  Server Management Software : NEC ESMPRO Manager (Windows), NEC ESMPRO Agent  User’s Guide for server, chassis, and Consolidated PSU The express setup installation is not supported in the server.  Operating system  For details as specifications and connections limited by OS, refer to this guide and hardware list“.  Processor  The features of the Intel ® Atom™ processors supported in the server are as follows: Category 64 bit Official Name Feature Overview Intel® 64 64 bit function Performance Enhanced Intel® SpeedStep® Technology, (Intel® Demand-Base Switching) Intel® Turbo Boost Technology Performance Intel® Hyper-Threading Technology Virtualization Intel® Virtualization Technology Security Intel® Execute Disable Bit Power conservation technology that changes voltage and frequency according to processor load. Technology that boosts processor frequency. A function that delivers thread-level thread parallelism on each processor core. Hardware (CPU)-assisted (CPU) virtualization technology. Technology that helps prevent malicious attacks abusing buffer overflow errors. Energy consumption Legend: X: Supported NEC Corporation Processor Atom N450 X X X X -: Not supported 4th Edition, April 2011 20 System Configuration Guide Express5800/E110b-M Supplementary Notes Flash FDD Flash FDD is an alternative device of FDD using USB flash drive. This device can be used as boot device without additional driver. Also, automatically recognized by OS as a Floppy disk drive after connecting to USB port since this device supports Plug and Play.*1 *1: Support OS only  Flash FDD (N8160-86) overview  USB2.0 compliant FDD emulation feature equipped in the USB Flash drive.  Stick type. FD icon/capacity is printed for easy recognition.  Capacity: 1.44MB (FAT formatted) *Same as one FD(2HD)  Strap hole, Write protect switch.  Intended uses of FDD substituted by Flash FDD  Flash FDD can be used instead of FDD for the following uses. Arrange Flash FDD if needed for your system. Description Notes Installation of Microsoft Windows Server 2003 R2 or previous Windows Server OS Create Windows OS OEM-Disk Not required for Windows Server 2008 or later Linux OS installation Depends on the distribution BIOS/FW update Off line update of BIOS or some firmware Not required for the current models, because those support update by CD/DVD and online update. Express report service registration Required when the set up of Express Report Service Backup software When using disaster recovery option of CA ARCserve Backup on Microsoft Windows Server 2008 or later. Not required on Windows Server 2003/2003 R2 When additional driver is needed for Backup Exec Intelligent Disaster Recovery option or disaster recovery of NetVault. Not required when there is no additional driver Replacement/repair of Hardware Backup/restore of HW information (Serial Number, etc.) when replacement or repair of Hardware. Not required for the current models Log collection, etc. System event log/System information collection when offline When online, ESMPRO tool can collect System Event Log (SEL). Intended use Manual installation Install Maintenance NEC Corporation 4th Edition, April 2011 21 NEC Express5800 http://www.nec.com/express/ Copyright © NEC Corporation 2010. All rights reserved. • Microsoft and Windows Server are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or a other countries. • Intel and Intel Atom are registered trademarks or trademarks of Intel Corporation or its subsidiaries in the United States and other countries. countries • Linux is a trademark of Linus Torvalds. • Red Hat is a registered trademark of Red Hat, Inc. in the U.S and other countries. • All other products, brands, or trade names used in this document are trademarks or registered trademarks of their respective holders. • Specifications and technical data are subject to change without notice.