Transcript
4 0 0 A Dua l Input C la m p M e te rs + IR T he rm om e te r + NC V B uilt-in dual thermoc ouple inputs For T1, T2, and T1-T2 differential temperature measurement
C om m on F e a ture s :
• C omplete with C AT III-600V, double molded tes t leads , 9V battery, two Type K bead wire probes and cas e E X 6 2 2 a nd E X 6 2 3 A dditiona l F e a ture
• B uilt-in non-contact IR Thermometer with las er pointer for locating hot s pots • 8 to 1 dis tance to target ratio E X 6 1 3 a nd E X 6 2 3 A dditiona l F e a ture
• DC C urrent function ideal for automotive, heavy equipment and marine applications
Dual Type K Inputs for taking Built-in IR Thermometer for differential temperature readings quick and safe non-contact needed for superheat measurements. temperature measurements. Find hot spots fast!
S E R I E S
EX600
• True R MS meas urements for accurate AC Voltage and C urrent meas urements • Dual type K thermocouple input with Differential Temperature function (T1, T2, T1-T2) • B uilt-in non-contact Voltage detector with LE D alert • DC µA multimeter function for HVAC flame rod C urrent meas urements • Data Hold plus fas t P eak Hold of current s urges during motor s tartup • 40,000 count multimeter functions for DC Voltage, R es is tance, C apacitance, and Frequency for high res olution over wider ranges • Meas ures motor capacitors to 40,000µF • 1.25" (32mm) jaw opening for conductors up to 500MC M • R ugged double molded hous ing • Auto power off with audible alert and dis able function • Autoranging with manual override
Patented
Model Temperature (IR) AC Current DC Current Max resolution Basic ACA accuracy AC/DC Voltage (Max Res.) DC µA Current Resistance (Max Res.) Capacitance (Max Res.) Frequency (Max Res.) Temperature (Type K) Diode Test Duty Cycle Dimentions Weight
EX613 — 400.0A 400.0A 10mA ±1.5% 600V (0.1mV)/600V (0.01mV) 4000µA (0.01µA) 40.000MΩ (0.01) 10pF to 40,000µF (0.01nF) 40MHz (0.001Hz) -58 to 1832°F (-50 to 1000°C) < 2.8V 0.5 to 99.0% 9x3.1x1.9" (229x80x49mm) 10.7oz (303g)
EX622 -58 to 518°F (-50 to 270°C) 400.0A — 10mA ±1.5% 600V (0.1mV)/600V (0.01mV) 4000µA (0.01µA) 40.000MΩ (0.01) 10pF to 40,000µF (0.01nF) 40MHz (0.001Hz) -58 to 1832°F (-50 to 1000°C) < 2.8V 0.5 to 99.0% 9x3.1x1.9" (229x80x49mm) 10.7oz (303g)
EX623 -58 to 518°F (-50 to 270°C) 400.0A 400.0A 10mA ±1.5% 600V (0.1mV)/600V (0.01mV) 4000µA (0.01µA) 40.000MΩ (0.01Ω) 10pF to 40,000µF (0.01nF) 40MHz (0.001Hz) -58 to 1832°F (-50 to 1000°C) < 2.8V 0.5 to 99.0% 9x3.1x1.9" (229x80x49mm) 10.7oz (303g)
O rde r ing Infor m a tion: EX613 ....400A AC/DC Clamp Meter+Dual Type-K Inputs EX622 ....400A AC Clamp Meter+Dual Type-K Inputs+IR EX623 ....400A AC/DC Clamp Meter+Dual Type-K Inputs+IR
EX613-NIST ......EX613 with Calibration Traceable to NIST.
more infor for Extech EX613
Phone: 01235 838 555 Email:
[email protected] Web. www.airconcern.co.uk Air Concern Ltd, Building 173 Curie Avenue Harvell Didcot, Oxfordshire