Transcript
DTP T 3G-SDI 230/330 D • Setup Guide This setup guide provides instructions for an experienced installer to set up and operate the Extron DTP T 3G-SDI 230/330 D series of SDI extenders. The DTP T 3G-SDI 230 D and 330 D products can transmit video, control, and audio (if applicable) signals up to 230 feet (70 meters) and 330 feet (100 meters), respectively.
POWER 12V 1.0A MAX
I A
3G/SDI IN
+ –
L O O P
B
C
AUDIO IN
CONFIG
T H R U
RS-232
Tx Rx G Tx Rx
IR
OVER TP
F D
A B C D E F G H I
H E
OUT HDBT DTP
G
DTP T 3G-SDI 330 D
SDI Input connector SDI Loop Thru connector Audio Input connector Over TP RS-232 and IR connector USB Config port DTP Out connector (Step 4, page 2) HDBaseT/DTP mode switch Power connector (Step 6, page 2) Power LED (Operation, page 3)
Wall Stud
DTP T 3G-SDI 230/330 D Front Panel
DTP T 3G-SDI 230/330 D Rear Panel
Signal Output Cable
Installation Step 1 — Prepare the Mounting Surface
Screws or Nails
AU
-S
DIO
DI
IN
IN
T H R U
IR
OVER TP
RS-232
a.
3G
L O O P
Tx Rx G Tx Rx
NOTE: Use a wall box with a depth of at least 3.0 inches (7.6 cm). Alternatively, the included mud ring (MR 100) can be used. For more information, see the full product user guide at www.extron.com. The installation must comply with the National Electrical Code and all applicable local codes.
n tro
Ex
Extron DTP T 3G-SDI 330 D
Place the wall box against the installation surface and mark the opening guidelines.
Decora Faceplate
b. Cut out the material from the marked area. c.
Secure the wall box with 10-penny nails or #8 or #10 screws, leaving the front edge flush with the surface.
d. Run all required cables (see steps 4, 5, and 6) and secure them with cable clamps.
TIP: To ensure a proper fit the unit in the junction box, do not install boots on TP cables and RJ-45 connectors.
Step 2 — Disconnect Power Disconnect all equipment from power sources.
Step 3 — Connect Inputs to the Transmitter
A B C
SDI input connector — Connect a coaxial cable to the output port of the SDI or HD-SDI video source. Loop Thru SDI connector — Connect a display to this BNC loop-through connector for local monitoring. Audio input — Connect an unbalanced stereo audio source to this 3.5 mm mini stereo jack. NOTES:
• The DTP T 3G-SDI 230 D and 330 D products do not embed this audio onto the SDI signal. Audio is transported separately over the DTP connection.
• AES/EBU digital audio is passed through with the supported SDI format.
DTP T 3G-SDI 230/330 D • Setup Guide (Continued)
HDBaseT/DTP mode switch — Set this 2-position, recessed switch to configure the output between HDBaseT and DTP modes. When configured for HDBaseT, use an HDBaseT-compatible receiver. When configured for DTP, use a DTP-compatible receiver.
Tx Rx
G
Transmit pin on connected unit Receive pin on connected unit Ground Transmit pin on connected unit Receive pin on connected unit
Tx Rx G
USB Config port — Connect a PC to this mini USB-B port for device configuration and firmware updates.
IR
E
Connected RS-232 and IR Device Pins
Tx/Rx Pins OVER TP
Over TP connector — Plug an RS-232 or modulated IR device into this RS-232/IR pass-through port. Wire the cable as shown to the right.
RS-232
D
NOTE: Prior to setting the switch, ensure that the transmitter and receiver are both powered off and that the correct DTP or HDBaseT receiver is connected. SIG
LINK
SIG
LINK
Step 4 — Run Cables Between Units Connect the rear panel transmitter output (see F on page 1) to the rear panel receiver input using shielded twisted pair (STP) cable.
OUT
IN
Rear Panel TP Ports
ATTENTION: • Do not connect these outputs to a telecommunications or computer data network. • Ne connectez pas ces appareils à des données informatiques ou à un réseau de télécommunications. • Do not use Extron UTP23SF-4 Enhanced Skew-Free AV UTP cable or STP201 cable. • N’utilisez pas le câble AV Skew-Free UTP version améliorée UTP23SF d’Extron ou le câble STP201. For optimal performance, Extron highly recommends the following: zz
RJ-45 termination with STP cable must comply with TIA/EIA T 568B wiring standard for all connections. For more information on cable wiring and termination, see the full product user guide at www.extron.com.
zz
Use shielded twisted pair cable, 24 AWG solid conductor or better, with a minimum cable bandwidth of 400 MHz.
zz
Use shielded RJ-45 plugs to terminate the cable.
zz
Limit the use of RJ-45 patches. Overall transmission distance capabilities vary depending on the number of patches used. If possible, limit the number of patches to a maximum of 2.
zz
If RJ-45 patches must be used in the system, shielded CAT 6 (or better) patches are recommended.
Step 5 — Connect Outputs from the Receiver The DTP T 3G-SDI 230/330 D series is compatible with DTP 230 and DTP 330 receivers (sold separately). a.
Output connector — Connect a DP or HDMI cable between this port and the input port of the display. For complete instructions on connecting receivers or switchers to outputs, see the user guide for the appropriate product at www.extron.com.
b. Audio output — Connect a stereo audio device to this 3.5 mm mini stereo jack to receive the passed through
unbalanced audio. c.
RS-232/IR Over TP connector — Plug an RS-232 or modulated IR device into the RS-232/IR pass-through port. Wire the connector as shown in step 3 above.
Step 6 — Power the Units ATTENTION: • Extron recommends installing the DTP T 3G-SDI into a grounded, UL Listed electrical junction box. • Extron recommande d’installer le DTP T 3G-SDI dans un boîtier d’encastrement électrique mis à la terre, listé UL. When configured for DTP mode via the rear panel switch (see G on page 1), the unit can be powered either locally, with the included external 12 VDC power supply, or over the DTP line by a locally powered receiver or switcher. When configured for HDBaseT mode, remote power capability is disabled and the unit must be powered locally. 2
DTP T 3G-SDI 230/330 D • Setup Guide (Continued) To power the unit locally in either mode, wire the 2-pole captive screw connector for the included external 12 VDC power supply as shown at right. Plug the power supply captive screw connector into H.
Smooth
Ridges
A
Step 7 — Final Installation a.
3/16" (5 mm) Max.
A
Make all connections and test the system for satisfactory operation.
b. At the power outlet, unplug the power supply. c.
Mount the transmitter into the wall box and attach the supplied Decora® faceplate to the unit.
d. At the power outlet, reconnect the power supply. This can power up both the transmitter
and receiver, unless in HDBaseT mode.
Power Supply Output Cord
I A
3G/SDI IN
L O O P
Operation After all devices are powered up, the system is fully operational. See the definitions of the power indications below.
B
T H R U
RS-232
F D
Tx Rx G Tx Rx
IR
Power LED — This two-color front panel LED on both DTP T 3G-SDI 230 and 330 model transmitters lights to indicate signal and power status as follows:
C
AUDIO IN
OVER TP
Transmitter Power Indicator
I
Captive Screw Connector
SECTION A–A
I
Amber — The unit is receiving power but no signal on the SDI input. Green — The unit is receiving power and a signal is present on the SDI input.
DTP T 3G-SDI 230/330 D FrontDVI-D Panel
Application Diagrams
DDC ROUTE REMOTE
The following figures show typical applications for the DTP T 3G-SDI 230/330 D transmitters.
AUDIO
ON 1 2 LOCAL
Audio
Local Monitor
3G-SDI
3G-SDI
HDBT
100-240V ~ 2.0 A MAX
OUT
LINK
XTP
IR
DTP
OUT
Tx Rx G Tx Rx
4 S/PDIF OUT
REMOTE
RESET
3
5
4
7
6
INPUTS
2
SIG
IN
COM 2
COM 3
Tx Rx G
Tx Rx G
IR/SERIAL 1 2
1
RELAYS 2 C 3 4 C
S G
DIGITAL I/O
1 2
3
LAN 1
PWR OUT = 6W
LAN 2
8 SIG
LINK
XTP
IR
Tx Rx G Tx Rx
IN
DTP
L
1 2
R
L
R
L
3 4
R
L
R
L
5 6
R
EXP
OVER DTP IR
Tx Rx G Tx Rx
POWER 12V 0.7A MAX
SIG
LINK
DTP HDMI 330 Rx
OUTPUTS L
DTP IN
Extron DTP HDMI 330 Rx Receiver
AUDIO
R
HDMI
Flat Panel Display
Figure 1. A Typical DTP T 3G-SDI 230/330 D Application
1 2
R
Scaling Presentation Matrix
RS-232
L
/4
1
R
CLASS 2 WIRING
LAN 3
+48V L
Extron DTP CrossPoint 84 IPCP SA CATx Cable up to 230' (70 m)
8
4 G
eBUS +V +S -S G
IR
OVER TP
RS-232
DTP
50-60 Hz
COM 1
Tx Rx G RTS CTS
S G
Tx Rx G Tx Rx LINK
XTP
R
HDBT RS-232
1
Tx Rx G
AMP OUTPUT
4 SIG
OVER TP
RS-232
DTP
IR
Tx Rx G Tx Rx LINK
DTP OUT
3 4
1 2
MIC/LINE
3 4
AUDIO OUTPUTS
3 SIG
XTP
AUDIO INPUTS
OUTPUTS
DTP CROSSPOINT 84
2
CONTROL
RS-232
RS-232 1
L
L
1 2
IR
Tx Rx G Tx Rx
Receiver
CATx Cable up to 330' (100 m)
Transmitter
OVER DTP RS-232
Extron DTP HDMI 330 Tx
PC
LINK
IR
OVER TP
Tx Rx G Tx Rx
RS-232 / IR
LINK
AUDIO
HDMI
Extron DTP T 3G-SDI 330 D
3
SIG
INPUTS
POWER 12V 0.7A MAX
AUDIO IN
DMP EXPANSION
T H R U
3G-SDI Camera
DTP HDMI 330 Tx
3G/SDI IN
L O O P
R
L
R
L
3 4
R
R
R
DTP T 3G-SDI 230/330 D • Setup Guide (Continued)
Extron Headquarters +800.633.9876 Inside USA/Canada Only Extron USA - West Extron USA - East +1.714.491.1500 +1.919.850.1000 +1.714.491.1517 FAX +1.919.850.1001 FAX
Extron Europe +800.3987.6673 Inside Europe Only +31.33.453.4040 +31.33.453.4050 FAX
Extron Asia
Extron Japan
Extron China
+65.6383.4400 +65.6383.4664 FAX
+81.3.3511.7655 +81.3.3511.7656 FAX
+86.21.3760.1568 +86.21.3760.1566 FAX
Extron Middle East +971.4.299.1800 +971.4.299.1880 FAX
© 2015 Extron Electronics All rights reserved. www.extron.com
Extron Korea +82.2.3444.1571 +82.2.3444.1575 FAX
Extron India 1800.3070.3777 Inside India Only +91.80.3055.3777 +91.80.3055 3737 FAX
68-2683-50 Rev. A 03 15