eZtrend® QXe X Series Advanced Graphic Recorder Specifications 43-TV-03-12 February 2011
Crystal Clear Display
5” Digital Colour LCD (TFT)
QVGA Resolution (320 x 240 pixels)
Clear and intuitive operation
Industrial rugged Touch Screen with rapid navigation
Comprehensive Connectivity
10/100 Ethernet (DHCP), OPC Server Web and Email
FTP and TCP/IP
Modbus Master and Slave (option)
RS485 Modbus Protocol (option)
Front USB port as standard for keyboard and mouse. Rear USB option.
Data Storage
On-board non-volatile memory - up to 400MB
Removable USB storage
No moving parts - all solid state Flash memory
Security Stringent - Total Data integrity
Plus..
Health Watch for preventative maintenance
Remote Access - Advanced Software Data Analysis at your PC and Remote Viewing
Independent Chart and Logging speeds
Global Language Support
Rapid review and replay of data at recorder
Approvals - CE, CSA, UL & NEMA 4X/IP66 (option)
Up to 10Hz (100 msec) Logging (including expansion
Password Protection - 21CFR Part 11
ESS - Extended Security System
Up to 12 Analogue Inputs
Password Network Synchronisation
4 Pulse Inputs via the Digital I/O card (option)
Reports - System generated
Concurrent Batch mode
AMS2750 Process Capabilities
card option)
eZtrend® QXe
Recorder Function
The eZtrend QXe uses a digital colour TFT LCD
Honeywell’s eZtrend QXe recorder provides
screen to provide easy to read displays with wide
flexible electronic data acquisition and recording in
viewing angles for the best all around data viewing.
a DIN standard 144mm format recorder.
2
The touch screen operator interface provides fast, easy
Up to 12 Analogue inputs with at least 70MB
access to the recorder menus making set up and data
standard on-board memory plus additional
analysis quick and efficient. Navigation through the
removable storage media.
menus and text entry are direct and intuitive.
eZtrend® QXe
3
Data Export - Removable USB flash storage device.
Features
Data is stored in a secure binary encrypted format, with
Display 5” Colour Active TFT - with more than 256,000 colours makes it easy to interpret process data and take action with the intuitive bar charts, digital values
the recorder’s configurations, providing added security of the data files. Removable USB flash storage devices
or trends displays. A screen saver function can be set from 1 to 720 minutes to extend the life of the backlight. Touch Screen - the heavy duty durable touch screen provides easy data entry and rapid navigation though the menus.
External USB Devices
Help Files - A complete contextual help system can
The recorder has two USB host ports, one at the front
be accessed and visualised on the screen of the
(standard) and one at the rear available on the
recorder.
Communications card (option). This is for attaching external USB devices such as a keyboard, mouse or a USB data storage key. The keyboard and mouse can be
Communications Ethernet Connectivity - the Ethernet (DHCP standard) connection, with support for various protocols, provides unlimited connectivity to local area networks (LANs). The standard Ethernet interface makes networking of the recorder to a LAN or the world wide web fast and convenient. Dynamic Host Configuration Protocol (DHCP) automatically acquires the settings (IP address) for network communications from a DHCP server.
used to navigate the recorder’s screen and enter text.
Remote Viewer Extends the user interface of the recorder onto the desktop PC. Providing remote viewing of the unit launched from a web browser. Full remote control is available as an option. Compatible with Microsoft™ Internet explorer 6 and higher.
Security
Simple Network Time Protocol (SNTP) - The
Total Data Integrity - data is stored in secure
recorder can be synchronised over the ethernet
encrypted files making it easy to retrieve the data
network via a SNTP client or synchronise other
dependent on process information. Data is automatically
recorders via a Server.
recognized without having to remember file names.
Web Server - with the recorder connected to a LAN,
Password Protection - Up to 4 levels of password
all process variables, alarm and messages can be
protection with up to 50 different users are available.
viewed from an internet browser; values are
Multiple levels f password protection and an audit
automatically refreshed.
trail of actions enhance the security of the data. Extended Security System (option) - ESS provides
Data Storage
extended features including entry of unique User ID’s
Internal Data Storage - 70MB to 400MB of expandable
and associated passwords, time-out of password
internal non-volatile flash memory is available for data
entry, password expiration, and traceability of user
storage and chart history.
actions. ESS is compatible with the requirements of
Example: Internal memory / Logging rate = 1 sec
21CFR part 11.
Pens
70MB
400MB
6
32days
182d
12
16d
91d
24
8d
45d
Password Network Synchronisation - Password can be synchronised over the network, a recorder can be designated as a master of a password group and other recorders can be added to that group as slaves, the master will ensure all passwords are synchronised with all recorders in it’s group.
eZtrend® QXe
4
Modbus Master/Slave
Concurrent Batch Mode (option)
The recorder can communicate with up to 32 slave
Batch enhances the management of data collected in
devices on both RS485 and/or Ethernet at a maximum
non-continuous process, known as batch processing,
poll rate of 1 second (slowest 1 hour), with each slave up
used in thermal treatment, sterilisation, food processing
to 8 “transactions” can be performed where a transaction
and chemical reactions. Batch mode has changed to
can be retrieving 1 or more registers from a slave or
allow concurrent batches, where each batch is associated
sending one or more Pens to a slave.
with a group, so all pens within Group 1 will belong to the batch that is controlled by Group 1. Batch features
Reports
include Pause chart when batch stopped, Batch Logging
Reports can be generated manually or on a periodical
control, List driven data fields, Automated batch counters,
basis using event system to show daily/weekly/monthly
Event driven batch control, Updated control and
totals, max mins, averages etc., the reports can be
feedback, Batch mode State and Count
printed, e-mailed as attachments or exported to external
inscripts/embedded variables.
media. The reports will be in RTF format for use in MS Word or other compatible word processors.
AMS2750 Process Mode (option) Provides on-line monitoring in the process recorder to
Events/Counters (option)
alert the user to potential AMS2750D non-compliance
Certain conditions or operations can be set up and
issues. Monitors and alerts the user concerning - days
logged according to the time and date of the occurrence.
until next SAT, days until next TUS, days until next
Subsequently events can be reviewed in a list or
control T/C change out and days until the recorder
represented on a graph. Up to 16 User Counters are
requires calibration. The recorder also provides an
available and can be used as a part of the Events
overview of T/C usage for all survey T/C’s providing a
system. User Counters can be set up as a Cause or an
colour coded for early warning screen (5 day expiration).
Effect of an Event. Preset Markers can be configured and used when applying a Mark to the chart through the event system, the alert system or manually.
eZtrend® QXe
Standard features
prompts for English UK & US, French, German, Italian, Spanish, Brazilian, Polish, Hungarian,
Directive.
Slovakian, Czech, Turkish, Romanian, Russian,
Soft Alarms - 6 "software" alarms per pen are
Portuguese, Greek and Bulgarian.
added security to seal the front door and rear
or digital outputs to activate the user’s external
wiring when using optional rear cover to prevent
equipment.
undetected entry to these areas of the recorder.
Communications - the recorder supports FTP,
data and setup transfers or remote screen
over Ethernet (DHCP standard) communications
through this port. Front USB port is standard and
port and Modbus RTU (slave mode) via an
the rear USB port is available with the
RS485 port (option). USB ports allow the use of
Communications card option. Use these ports to
an ASCII barcode reader. Email sent to your
attach external devices (keyboard or mouse), for
network connected PC triggered by an Alarm or
direct interfacing with the recorder.
zoom-in on a specific area on the screen. The
Logging rates - logging rates can be
data can easily be replayed at the recorder with
programmed completely separate from the chart
the ability to “zoom”. The touch screen makes it
display speed, allowing the data to be displayed
fast to review and analyse historical data. A
and stored at the rates that best suits the
"jump" function allows you to go from any
application.
message list directly to the trend showing the
Logarithmic Scales - all displayed scales can
occurrence of the alarm.
Dual Cursors in Replay - Displays the time and date between two independently positioned cursors on a replay screen. Also provides digital readings and shows the max min between the cursors.
Alert System - Error messages can be
Enclosure rating - standard NEMA 3 / IP54
Pulse Inputs - The 8 Digital I/O option card has 4 channels that can be set as pulse inputs (first
displayed for serious errors such as a
4 channels). The operating frequency for pulse
connectivity problems or can be used as an
inputs on the Digital I/O card is 1kHz max.
early warning message system to notify the user
Rate up and rate down alarms - Users can
on potential memory storage space availability.
configure a rate of change in engineering units
Replay with Zoom - Select replay mode and
Independent Display Chart Speeds and
available as an option.
USB Ports - Front and rear USB host ports for
Modbus TCP/IP (slave mode), web and email
type front face protection. NEMA 4X / IP66
Security tag - “wire seal provision” that provides
of-limit conditions. These can be tied to the relay
be set as linear or logarithmic.
Language Support - standard language
Voltage Directive and 89/336/EEC EMC
an Event.
CE Mark - Conformity with 73/23/EEC, Low
easily set up to display and record selected out-
5
Sound Effects - Sound effects, Used as an
to be checked over a time period in seconds
event effect the user can pick from a list of 20
from 1 to 3600 (1 hour).
different sounds these can be configured to play
Fuzzy Logging - this standard feature provides
a single time or repeat continuously until a
a unique method to increase the storage
corresponding “stop” event is triggered for that
capacity of the recorder. The data is monitored
sound. The sounds themselves can be replaced
to determine changes in process data; if no
on the recorder with custom sounds.
changes are observed data is logged
User Variables - Provides the user with the
periodically. If data is changing rapidly, it is
ability to set values for up to 32 variables that
recorded normally at the programmed rate. By
can be used in the maths and scripts. Values
not logging data that is static, data compression
can be altered to effect calculations without
of up to 100:1 or more can be achieved saving
having to change the configuration. User
valuable memory.
variables are non-volatile.
eZtrend® QXe
Options – Hardware
6
available: 2 inputs on 8 channel Alarm card, 8
SPCO 240V, 8 Digital I/O - SPNO 24VDC.
inputs on Digital I/O card. The digital inputs allow
Programmable alarm set points can be
users to initiate, from a remote location via a dry
configured to activate up to 8 outputs.
contact closure, selected recorder functions.
RS485 Modbus - the RS485 connection allows
process data to be transferred to other devices, or to record data received in MODBUS RTU protocol (slave mode only).
Portable Recorders - Portable cases available as an accessory item.
Digital Input - Two digital input options are
Alarm Card - 4 or 8 outputs relay contacts
Approvals - CSA and UL
24VAC/DC Power Supply - 20 to 30VDC / 20 to 25VAC
24VDC Transmitter Power Supply - can supply up to 130mA to external transmitters.
Print Support - Network printing from status, message and replay screens. Plus screen capture facility of process screens instantly using a basic USB standard PCL printer.
eZtrend QXe Standard Screens Up to 10 screens displaying multiple combinations of Charts, Bars and Digitals can be configured, 6 examples below.
eZtrend® QXe
7
Firmware Credit System The credits system is a flexible way of adding to the recorder features without having to upgrade the firmware. Simply purchase a number of credits to cover your current and possible future requirements and the recorder will be delivered with the credits loaded. Credits can be applied as desired to the Firmware functions until the total number of credits purchased has been used up. Additional credits can be purchased later if new features are to be activated and not enough credits are available to support these additional functions. Firmware options are selected using the Model Selection Guide. Details of each firmware option are listed here.
Firmware option
Credit value
Description
Full Maths
4
Full (Block) Math - this can handle math expressions that can consist of expressions up to 100-characters in length. (Note 1)
Totalisers/
4
Each pen can be associated with a totaliser. Using extra pens, the totalised values can be displayed and recorded; multiple totals can be calculated out of the same variable (weekly, monthly, etc.). The totaliser function can handle Fo and Po sterilisation calculation. (Note 1)
Reports
3
Generate reports manually or using the event system to show daily/weekly/monthly Totals, Max/ Mins, Averages, Current Value. Messages, Message Lists - Alarm, System, Diagnostic, Security & User, Counters, Digital Inputs, and Digital Outputs. Reports can be printed, e-mailed as an attachment or exported to external media in RTF format. Also batch report format to support batch operation.
Health Watch/ Maintenance
2
The recorder keeps track of important “life actions” for improved diagnostics and preventative maintenance notification. Including Powered On, Last powered On, Time On since power up, Total On time, Total Off time, Longest Off time, Lithium cell life, Backlight life left at 100% brightness, Compact Flash insertions, Hi/Lo CJC value (Hi & Lo temps), Analogue In last factory/user cal, Relay operations.
Print Support
2
Network printing from status, message and replay screens. Pluse screen capture facility of process screens instantly using a basic USB standard PCL printer.
Batch/Groups
5
The Batch function allows the user to segment portions of data for further analysis. The Batch function manages sections of data. Concurrent batches are now associated with a group of pens. The pens with in each group will belong to the batch that is controlled by that group. Batches can be controlled through the event system and batch markers are setup by the user and are used to identify and analyse batches of data. Supports up to 6 concurrent batches.
Counters
3
User Counters can be set up and used as a part of the Events system to count an occurrence. Other counters are available depending on hardware availability. Eg. Alarm, Event, Digital Input, Relay Output and Pulse counters.
Modbus Master
10
Modbus master enables the recorder to communicate with up to 32 Slave devices on both Ethernet and RS485. The recorder itself can also act as a slave device while also being a master. Mod-bus master can also be used in conjunction with OPC to enable the recorder to act as a communication bridge.
Sterilisation calculation
eZtrend® QXe
Firmware option Events
8
Description
Credit value
6
Events are certain conditions or operations that can be set up and logged according to the time and date of an occurrence. Subsequently events can be reviewed or displayed on a graph. The Event Causes include:
The Event Effects include:
Alarms - Into/Out of and Alarm Ack
Mark Chart - User Defined/Preset
Totals - Start/Stop/Reset/Reset and Start
Logging - Start/Stop
Digital Input - ON/OFF/State Change T/C Burnout
Totaliser - Start/Stop/Reset/Reset & Start,
Scheduled - Once/Interval/Specific Days/
Digital Output - ON/OFF
Month End
Alarm Acknowledge
User Counters
Emails, Screen Change, Print Screen,
Max/Mins - Reset System - Power ON/Setup Change/ Internal Memory Low/Export Memory Low/ FTP Memory Low User Action - Mark Chart, Batch - Start/Stop/Pause. TUS - Start/Stop AMS2750 Timer -TC Timers/Process Timers
Counters - Reset/Increment Max/Min (Reset) Chart ControlPause/Stop/Resume/Clear/Prefil Clear All Messages, Delayed Event Script Timers Start/Stop/Reset/Reset & Start Play Sound - Start/Stop Display Alert, Reports Batch - Start/Stop/Pause
Each event marker can be recorded for analysis using the Trend Manager Analysis Software Suite. (Note 2)
Update Tabular Readings
Remote Viewer
3
Extends the user interface of the recorder onto the desktop PC. Providing full remote control of the unit launched from a web browser.
Email
3
Setup email accounts to send the following: When an Alarm is triggered or an Email can be sent as a part of an Event occurring, such as: Alarms - In/Out/Ack , Totaliser – Start, Stop or Reset, Digital Inputs – On, Off or State change, TC Burnout – on a specific Analogue Input channel, Scheduled Events – Once, Interval, Specific days, Month End.
OPC Server
8
Pwd Net Sync
5
OPC (OLE for Process Control) - Software application for realtime interfacing between servers and clients. OPC is a software standard that defines common interfaces for data exchange between devices such as recorders, controllers, PLC’s and Windows™ based applications Password Network Synchronisation. Password can be synchronised over the network, a recorder can be designated as a master of a password group and other recorders can be added to that group as slaves, the master will ensure all passwords are synchronised with all recorders in its group. Maximum number of password slaves in one group is 31.
AMS2750 Process
5
AMS2750 Process activates the Process Mode screen and the AMS2750 process configuration menus for furnaces and sensors in accordance with AMS2750D specification, including Thermocouple tracking.
Extra Pens
2
4 extra pens to store and display totalised values, results of calculations, etc. Maximum is up to 16 extra pens for the QXe recorder.
eZtrend® QXe
9
Notes 1.
Additional pens (“Extra Pens”) can be used to display and store the results of calculations, totalisers, variables imported via communications, or to store values.
2.
Event markers are required to automatically reset the totalisers, for example on a periodic basis or on an external condition. (Not necessary if the totalisers are reset manually)
3.
Event markers are required to automatically reset the totalisers, for example on a periodic basis or on an external condition. (Not necessary if the totalisers are reset manually).
4.
Specification table for Sterilisation: The definition of Fo/Po is the sterilisation/pasteurisation time in minutes required to destroy a stated number of organisms with a known z at temperature T. For example, "F18/250" represents the time in minutes required to destroy a stated number of organisms at a temperature of 250°F (121.11°C) with a z = 18 degrees F. F values are used to compare the sterilizing values of different processes, however, F values cannot be compared unless the z values are the same. When temperature is not specified (for example, F = 8.6) it is understood that the temperature is 250°F (121.11°C); the subscript O (as in the term Fo = 7.4) is used to indicate that the z = 18 degrees F and the temperature is 250°F (121.11°C).
eZtrend® QXe
The TrendManager Software Suite
10
Modbus Profile Configuration Tool - this is a tool that comes as part of the TrendServer Pro software that allows
The TrendManager Pro Software Suite complements the
the user to set up Modbus Device Profiles for use by the
capabilities of the “X Series” recorders by providing the
Communications Server. It allows the user to set up other
benefits of viewing, configuration, network
Modbus devices other than the X Series recorders to get
communications, database management, data analysis
real time data into TrendServer Pro.
and report generation using a personal computer. It ties the process together, providing for real-time or FTP
Communications Server
communications with the recorders through a Local Area
The Communication Server is supplied with TrendServer
Network (LAN).
Pro. It manages real-time communications, distributed access to the stored data, time synchronisation over RS-
TrendViewer
485 and Ethernet networks. It is also available with a V2
TrendViewer - is the standard software provided with the
compliant OPC Server to make it easier to interface third
recorder that displays and prints data imported from the
party HMI software packages that support an OPC Client.
storage media used by the recorder.
The Communication Server provides security for the transmission and storage of process data. A Comms
TrendManager Pro
option card and expansion card are required for the eZ-
TrendManager Pro is an advanced data
trend QXe recorder.
analysis/archiving software package, providing full configuration of the recorders. TrendManager Pro is a
Database Management Tool
stand-alone package that delivers to the user total
Database Management Tool - this software application
recorder configuration, allowing the user to archive,
works with TrendManager Pro and TrendServer Pro to
graph, print and export data. TMP also allows files to be
provide safe administration of data with tools to archive,
exported using comma separated variables (CSV) format
sort, move, copy and delete the data stored in local and
that can be imported in most computer software.
remote databases. The Database Management Tool software is supplied with TrendServer Pro.
TrendServer Pro TrendServer Pro is a fully network aware software
IQOQ Protocol Document (TrendServer Pro only.)
package for real-time viewing and archiving of data with
Custom built IQOQ reports can be generated based on
communications to the recorder. It supports all the
the configuration of the recorder. The configuration can
capabilities of TrendManager Pro plus real-time data
be validated as a process of confirming that a piece of
acquisition, FTP (File Transfer Protocol) and web browser
equipment or process meets the stated requirements to
access. TrendServer Pro provides secure multi-level,
produce a regulated product.
multi-user access to the recorder data by various departments with security. Standard features of
Report Generation Tool - AMS2750D
TrendServer Pro include data archive tools E-mail set up
PC software that uses a TUS data file generated by the
and alarming, graphing, print, import and export data
Multitrend SX recorder to generate a temperature
facilities.
uniformity survey report. It produces a report that documents the uniformity performance of a furnace
TrendServer Pro with OPC Server - provides the same
based on the AMS2750D specification. AMS2750D is the
functions as the TrendServer Pro tools, but includes the
specification that covers pyrometric requirements for
added function of an integrated OPC Server to allow easy
thermal processing equipment used for heat treatment.
interfacing to third party HMI software packages that support an OPC Client. This provides a real-time interface between servers and clients.
eZtrend® QXe
11
Minimum System requirements for TrendViewer, TrendManager Pro:·
Minimum System requirements for TrendServer Pro:
1GHz Pentium processor or higher
1GHz Pentium processor or higher
CD-ROM drive
CD-ROM drive
Monitor screen resolution 1024 x 768 recommended minimum, high colour
Monitor screen resolution 1024 x 768 recommended minimum, high colour
Windows™ 2000, XP, Vista and Windows 7 (32 bit – Professional and Ultimate edition)
Windows™ 2000, XP, Vista and Windows 7 (32 bit – Professional and Ultimate edition)
512 Mbyte of RAM (min 512 Mbyte recommended)
512 Mbyte of RAM (min 512 Mbyte recommended)
16 bit colour graphics, 24 bit recommended
TCP IP installed
50 Mbyte free hard disk space
2 Gbyte Hard-drive free disk space
A mouse
A mouse
Flash card reader or USB port
Flash card reader or USB port
Specification Digital indicators and Display
Design Attributes Display size and Type: 5” diagonal, Digital Colour LCD (TFT) with Touch Screen Industrial grade with brightness adjustment and wide viewing angle Resolution: QVGA (320 x 240 pixels). Screen Saver: Set in minutes from 1 to 720, can be set to dim the screen or to switch off. Automatic wake-up facility in the case of an alarm. Brightness adjustment: Adjustable between 10 and 100%, default set to 80% brightness. Backlight life time: 40,000 hours to half brightness when used at 100% (62,500hr if used at 80%). Maximum luminosity 450 cd/m2. Touch Screen life: 1,000,000 touches
Display Update Rate
Display values updated every second
Status Display
A status bar, at the top of the recorder’s screen, displays the real-time icons of the recorder status, such as recording time left and alarm active.
Communications
Ethernet 10/100 base - T with RJ45 connector supporting Modbus/TCP, FTP, Internet, DHCP or fixed IP address. RS485 Modbus RTU (up to 115200 Baud Rate). RS485 port is available as an option on the Comms card.
Mathematics
Basic maths include Add, Subtract, Multiply, Divide, Modulo and power. Full Maths (option) support up to 100 character free form math expression for each pen. For example: SINE, COS, TAN, Log, Parenthesis (eg. A1 + A2), comms variables, free memory, and access to any data item variable (A1, P1, D1 etc.).
Front (std) and Rear (option) USB Ports
USB host ports front (std) and rear (option) for data and setup transfers through these ports. External devices keyboard or mouse, Barcode reader, or external mass storage device. (USB 1.1 compliant)
Standard Screens
Fully programmable display values in engineering units. Time & date stamp on every division. Sets of Standard screens are available to display data on a chart, digital reading, bargraphs or numerous combinations thereof. Screen properties can be modified on the recorder and customised to suit. Digital values displayed include alarms on bars, engineering units, pen name, tag, time and date, 20 character description and totalised values.
eZtrend® QXe
Specification Power Requirements
12
Design Attributes Voltage (VRMS): 100VAC to 250VAC (auto select). Frequency: 50/60Hz Power Consumption: <40W. 24V Optional instrument power: 20 to 30VDC/20 to 25VAC. Power Consumption: < 40 watts
Battery
Battery backed up for clock, replaceable lithium battery Type 6032, 3.0V – 10 years life (Recorder powered), 4 years life, typical (Recorder un-powered).
Data Storage
Local Mass Storage Options (Removable Media): USB memory key - no size restrictions but must be formatted (FAT, FAT16, TFAT, FAT32). USB hard drive - up to 120Gb, Internal Data Buffer: Non-volatile. 70MB (16 million acquisition values) and 400MB (up to 90 million points) Setup and screens: Stored internally on non-volatile memory Manual Saving: Data saving by inserting USB memory stick Data Saving Period: Related to log rate, number of pens, totals and alarms. Each pen is capable of its own independent storage rate. (200ms to 60 h). Data Format: Honeywell binary encoded format Recycling Mode: Internal memory has FIFO (First In First Out) capability where the newest data over-writes the oldest data.
Password Protection
Multiple Administrator control of password setup and management with four levels of password protection for – Engineer, Supervisor, Technician, and Operator. Up to 50 different users are available. Password protection restricts user entry to the recorder set up and specific screens. Engineer – Highest access to all levels, Supervisor, Technician and Operator. Supervisor – 2nd highest level including Technician and Operator access Technician – 3rd level including Operator access Operator – 4th and lowest level of access.
Languages
English UK & US, French, German, Italian, Spanish, Brazilian, Polish, Hungarian, Slovakian, Czech, Turkish, Romanian, Russian, Portuguese, Greek and Bulgarian.
Temperature Units
°C, °F, °K
Recorder Identification
Status bar: Alternately displays Recorder ID and Recorder Screen Name. Displays Time and Date.
Clock
Accuracy: ±29ppm (±1 minute/month) @ 25°C. Summer/Winter manual or automatic time adjustment or via communications. SNTP Client and/or Server included for synchronising over Ethernet.
Alarm Set Points
6 per pen integral “soft” alarm set points easily set by user to announce selected out of limit conditions; user can select if an alarm triggers a change in the chart background colour. Alarm triggers can be set for Hi, Lo, Deviation. Latched alarms require acknowledgement from the operator. Alarm Damping - 1 sec to 24 Hours; Hysteresis - +/- 100% of pen scale. An alarm can change the log rate on the affected pen.
Data Replay Mode
Data replay facility on chart displays at normal, fast or slow speeds with zoom and cursor. Jump facility from the alarm history list directly to the occurrence on the chart.
Display Chart Speeds
Chart rates: 1 mm/hour, 5 mm/hour, 10 mm/hour, 20 mm/hour, 30 mm/hour, 60 mm/hour, 120 mm/ hour, 600 mm/hour, 1200 mm/hour, 6000 mm/hour. Combinations of rates can be mixed and chart speeds can be set independently for each chart. Display speeds are independent of logging rate
Messages Screen
The message screen displays system information and records any setup activity that has been changed. It also provides warning and error message updates, lists alarm activity and will display user defined marks on a chart.
eZtrend® QXe
Specification
13
Design Attributes
CE Conformity (CE Mark)
This product conforms with the protection requirements of the following European Council Directives: 73/23/EEC, the Low Voltage Directive, and 89/336/EEC, the EMC Directive. Conformity of this product with any other “CE Mark” Directive(s) shall not be assumed.
Immunity Product Classification
Complies with EN61326 Class I: Cord Connected, Panel Mounted Industrial Control Equipment with protective earthing (grounding). (EN 61010-1)
Enclosure Rating
Front panel designed to NEMA3 / IP54 (Optional NEMA 4X / IP66)
Installation Requirements
Category II: Overvoltage (EN 61010-1) Pollution Degree 2
EMC Standards
Emissions - EN61326 Class A Immunity - EN61326 Industrial Levels
Safety
Complies with EN61010-1: 2001. Panel Mounted Equipment, Terminals must be enclosed within the panel.
Specification
Analogue Inputs
Number of Inputs
3, 6, 9 or 12 input channels
Input Types
mV, V, mA with external shunt (provided as standard), Thermocouple, RTD and ohms
Minimum Input Span
Range is fully configurable with span limitation of the operating range selected with 4% under range to 4% over-range capability (50V Range 2%)
Burnout (T/C)
Active (High or Low), Passive and Health watch/maintenance (option).
Cold Junction Compensation
Internal compensation with the ability to manually adjust values, External Input for compensation, External CJC value specified
Input Resolution
0.0015% (16 Bit ADC)
Input Impedance
Current loop resistance: 10 ohms, use ±0.1% external resistor. Volts >1MΩ, all other
Source Impedance
T/C and RTD: 100 ohms per lead maximum. (A single point cal on Slot A will improve accuracy for a lead resistance above 10 ohms).
Square Root Extraction
Available as standard on Volts and mA input types
Sensor Compensation
Single point and Dual point for every input type
Input Sampling Rate
Recorder has 2 available slots with up to 6 analog inputs each; first slot fixed. Analogue Input card (std): 200mS (5Hz), 500mS (2Hz) Analogue Input expansion card (option): 100mS (10Hz), 200mS (5Hz), 500mS (2Hz)
Scales, Linear & Logarithmic
Normal and Scientific notation. Decimal Point automatic or programmable
Input Isolation
300VAC channel-to-channel, channel-to-ground. (Resistance thermometers are not isolated for initial card, expansion card option RTs are isolated)
Noise Rejection (at 50/60Hz) +/-2%
Analogue Input card (std)
Engineering units, user definable (10 characters). Logarithmic Decade limits: -38 min, to +38 max, (recommend up to 20 decades on one screen to ensure clarity)
Common mode: 2Hz = -120dB, 5Hz = -120dB Normal Mode: 2Hz = -80dB, 5Hz = -25dB Analogue Input expansion card (option) Common mode: 2Hz = -120dB, 5Hz = -120dB, 10Hz = -120dB Normal Mode: 2Hz = -85dB, 5Hz = -80dB, 10Hz = -48dB
eZtrend® QXe
Specification
14
Logging
Logging Method
Sample, Average, Min/Max - can be set independently per pen
Logging Types
Continuous, Fuzzy
Logging Rate
From 100msec. to 60 hours per pen
Fuzzy Logging
A secure data storage technique which delivers data compression ratio of 100:1 or more; self teaching, storing the data at a variable rate to match the process
Specification Enclosure/Bezel
Mounting Panel
Physical Parameters Zinc plated steel case with high impact resistant polycarbonate bezel; scratch resistant lens (Polyethylene Terephthalate). NEMA 3 / IP54 protection rating standard. Optional NEMA 4X / IP66 (Front face only) Unlimited mounting angle. For the best view of the display the viewing angle should not exceed 45° from the left or right, 10° looking down and 30° looking up at the recorder display. Mounting adjustable for panel thickness of 2mm to 20mm. Adapter kits available for covering existing panel cutouts.
Dimensions
W: 144mm (5.67”), H: 144mm (5.67”), D: 200mm (7.87”). Additional 80mm (3.15”) clearance recommended for a straight type power cable and signal connectors. Cutout 138 x 138mm (5.43 x 5.43”)
Weight
2.4 Kg (5.3lb) max.
Colour
Bezel: Black
Wiring Connections
IEC Power Plug. Removable terminal strip for input and alarm connections
eZtrend® QXe
15
Input Range Performance and Accuracy For Analogue Input standard and expansion cards
Input Actuation (Linear) Millivolts DC
Volts DC
Range
Accuracy
Temp. Stability +/-
-5 to 5, -10 to 10,
+/- 0.2% F.S.
0.01%/ °C
-25 to 25, -50 to 50, -100 to 100,
+/- 0.1% F.S.
0.01%/ °C
-250 to 250, -500 to 500, -1000 to 1000
+/- 0.1% F.S.
0.01%/ °C
-0.3 to 0.3, -0.6 to 0.6, -1.5 to 1.5, -25 to 25, -50 to 50
+/- 0.1% F.S. +/- 0.1% F.S. +/- 0.1% F.S.
0.01%/ °C 0.01%/ °C 0.01%/ °C
-3 to 3, -6 to 6, -12 to 12, Milliamps **
Input Impedance
>10M ohms >10M ohms >10M ohms >1M ohms >1M ohms >1M ohms
4 to 20, 0 to 20
+/- 0.2% F.S.
0.01%/ °C
Ohms, 200
0 to 200
+/- 0.1% F.S.
0.01%/ °C
Ohms, 500
0 to 500
+/- 0.1% F.S.
0.01%/ °C
Ohms, 1000
0 to 1000
+/- 0.1% F.S.
0.01%/ °C
Ohms, 4000
0 to 4000
+/- 0.1% F.S.
0.01%/ °C
Input Actuation (Thermocouples)
Range
Reference Accuracy
Temp. Stability +/-
°F
°C
+/- °F
+/- °C
B*
500 to 1000 1000 to 3300
260 to 538 538 to 1816
8.1 4.0
4.5 2.2
0.01%/ °C
E*
-454 to -328 -328 to -94 -94 to 1832
-270 to -200 -200 to -70 -70 to 1000
21.6 3.1 1.3
12 1.7 0.7
0.01%/ °C
J*
-346 to 32 32 to 2192
-210 to 0 0 to 1200
3.1 1.2
1.7 0.7
0.01%/ °C
K*
-454 to -94 -94 to 2502
-270 to -70 -70 to 1372
36 1.8
20 1
0.01%/ °C
R*
-58 to 500 500 to 1202 1202 to 3214
-50 to 260 260 to 650 650 to 1768
9.0 3.6 2.7
5.0
0.01%/ °C
S*
-58 to 500 500 to 1832 1832 to 3214
-50 to 260 260 to 1000 1000 to 1768
6.3 3.2 2.7
1.5 3.5 1.8 1.5
T*
-454 to -346 -346 to 752
-270 to -210 -210 to 400
9.7 1.8
5.4 1
0.01%/ °C
L*
-328 to 32 32 to 1652 32 to 212
-200 to 0 0 to 900 0 to 100
212 to 600
100 to 316 316 to 830
1.2 0.7 25 6.2 2.8 1.7 2.8
0.01%/ °C
600 to 1526
2.2 1.3 45 11.2 5.0 3.1 5.0
G* (W_W26)
1526 to 2759
830 to 1515
2759 to 4199
1515 to 2315
2 0.01%/ °C
0.01%/ °C
eZtrend® QXe
16
Input Actuation (Thermocouples)
Range
Reference Accuracy
Temp. Stability +/-
°F
°C
+/- °F
+/- °C
32 to 356 356 to 2228 2228 to 4199
0 to 180 180 to 1220 1220 to 2315
4.5
2.5
3.6 6.7
2 3.7
M* (NiMo-NiCo) (NNM90)
-58 to 698 698 to 2570
-50 to 370 370 to 1410
2.0 1.4
1.1 0.8
0.01%/ °C
N* (Nicosil Nisil)
-328 to 212 212 to 2372
-200 to 100 100 to 1300
5.8 2.0
3.2 1.1
0.01%/ °C
Chromel/Copel*
-58 to 1112
-50 to 600
1.1
0.6
0.01%/ °C
P* (Platinel)
32 to 2534
0 to 1390
2.5
1.4
0.01%/ °C
32 to 356 356 to 3344 3344 to 4515
0 to 180 180 to 1840 1840 to 2490
6.3
3.5 2.2 6.5
0.01%/ °C
C* (W5, W26)
D*
Input Actuation (Linear)
Range
4 11.7
Accuracy
0.01%/ °C
Temp . Stability +/-
PT100 α = 0.00385
-328 to 1562
-200 to 850
1.1
0.6
0.01%/ °C
PT200 α = 0.00385
-328 to 1562
-200 to 850
1.1
0.6
0.01%/ °C
PT500 α = 0.00385
-328 to 1562
-200 to 850
1.1
0.6
0.01%/ °C
PT1000 α = 0.00385
-328 to 1562
-200 to 850
1.1
0.6
0.01%/ °C
100 ohm Nickel
-76 to 356
-60 to 180
0.9
0.5
0.01%/ °C
120 ohm Nickel
-112 to 500
-80 to 260
0.5
0.3
0.01%/ °C
Reference Temperature: 22°C
Reference Sample Rate: 2Hz (500msec)
Reference Humidity:
Long term stability:
65% RH +/-15%
Input Impedance
0.2%/year
* Does not includes reference junction calibration of ±1.0 º C using the standard “ice bath” method of calibration. Factory accuracy can be improved by performing a field calibration. Also does not include any error on the sensor. ** Tolerance for these input types includes that of the external shunt resistors (0.1% tolerance)
eZtrend® QXe
17
Specification Alarm Outputs (optional)
Options Programmable alarm set points (6 per pen) can be configured to activate up to 8 outputs. Update rate: 200 ms for all alarms. Number/Type:
4 or 8 relay contacts SPDT, 3A 240VAC, 3A 24VAC/DC, 0.2A 240VDC (noninductive, internally suppressed)
8 I/O - SPNO 1A 24VDC (non-inductive, internally suppressed)
Activation: Fully programmable internal alarm levels. Assignable to any relay output. Digital Input/Output (optional)
8 I/O: all channels may be selected freely as either digital inputs or outputs. Inputs: voltage free, isolated. The Digital I/O card also has 4 channels that can be set as pulse inputs (channels 1 to 4). The operating frequency for pulse inputs on the Digital I/O card is 1kHz max. 4 relay outputs: all four channels are relay outputs only. 8 relays/ 2 DI card: two outputs can be configured for use as digital inputs: A digital input is provided by a volt free contact between the normally open (NO) and the common (C) terminals of an output relay. If the 2 Digital inputs are used only 6 relay outputs are available. Closed <500 ohms, Open >300 kohms.
Agency Approval (optional)
CSA (Optional) CSA22.2-No.1010.1-2004 Certificate Number L211230. UL (Optional) ANSI/UL61010-1-2004 File # 201698.
Transmitter Power ( ti l) Miscellaneous
130mA @ 24VDC ± 3VDC.
Firmware credit options
Maths (Basics, Full, Scripting), Events, Totals, Reports, Health Watch/Maintenance, Printing, Batch, Counters, Modbus Master, Remote View, Email, OPC, Password Net Sync, AMS2750 Process, Extra Pens. Firmware Credit System on page 7
Optional customer ID Tagging (3 lines of up to 22 characters each line)
eZtrend® QXe
18
Specification Parameter
Environmental and Operating Conditions Reference
Rated
Extreme
Transport & Storage
67 °F to 77 °F 19 °C to 25 °C
32 °F to 122 °F 0 °C to 50 °C
32 °F to 122 °F 0 °C to 50 °C
14 °F to 140 °F –10 °C to 60 °C
50 to 65*
10 to 90*
5 to 90*
5 to 95*
Frequency (Hz)
0
0 to 70
0 to 100
0 to 100
Acceleration (g)
0
0.1
0.2
0.5
Acceleration (g)
0
1
5
20
Duration (ms)
0
30
30
30
Tilted Forward
5°
40°
40°
Any
Tilted Backward
5°
65°
65°
Any
Tilted to Side (+/-)
5°
65°
65°
Any
220 to 240
100 to 250
90 to 264
N/A
Low Voltage AC (Vrms)
24 +/- 2
20 to 25
20 to 25
N/A
DC Voltages
24 +/- 2
20 to 30
20 to 30
N/A
49.8 to 50.2
47 to 63
47 to 63
N/A
Ambient Temperature Relative Humidity (%RH) Vibration
Mechanical Shock
Mounting Position from Vertical
Power Requirements Mains Voltage (Vrms)
Frequency (Hz) Power Consumption
AC: <40W (max), DC: <40W (max). Typical 20W
Warm Up
30 minutes minimum
The maximum rating only applies up to 104°F (40°C). For higher temperatures, the RH spec is de-rated to maintain constant moisture content.
eZtrend® QXe
Connections
19
eZtrend® QXe
Installation
20
eZtrend® QXe
21
Sales and Service For application assistance, current specifications, pricing, or name of the nearest Authorized Distributor, contact one of the offices below.
Asia Pacific Global Technical Support Field Instruments Phone: +65 6580 3156 Fax: +65 6445-3033 Australia Honeywell Limited Phone: +(61) 7-3846 1255 FAX: +(61) 7-3840 6481 Toll Free 1300-36-39-36 Toll Free Fax: 1300-36-04-70 China – PRC - Beijing Honeywell China Inc. Phone: +(86-10) 84583280 Fax: +(86-10) 8458-4650 China – PRC - Shanghai Honeywell China Inc. Phone: (86-21) 5257-4568 Fax: (86-21) 6237-2826 China – PRC - Chengdu Honeywell China Inc. Phone: +(86-28) 66135078 Fax: +(86-28) 8678-7061 China – PRC - Xi’an Honeywell China Ltd Xi’an. Phone: +(86-29) 88337490 Fax: +(86-29) 8833-7489 China – PRC - ShenzhenHoneywell China Inc. Phone: +(86) 755-25181226 Fax: +(86) 755-2518-1221
New Zealand Honeywell Limited Phone: +(64-9) 623-5050 Fax: +(64-9) 623-5060 Toll Free (0800) 202-088 Singapore Honeywell Pte Ltd. Phone: +(65) 6580 3278 Fax: +(65) 6445-3033 South Korea Honeywell Korea Co Ltd Phone: +(822) 799 6114 Fax: +(822) 792 9015 Thailand Honeywell Systems (Thailand) Ltd. Phone: +(662) 693-3099 FAX: +(662) 693-3089 Taiwan R.O.C. Honeywell Taiwan Ltd. Phone: +(886-2) 22451000 FAX: +(886-2) 2245-3243
SE Asia Countries see Honeywell Pte Ltd (Singapore) for: Philippines, Pakistan, Cambodia, Guam, Laos, Myanmar, Vietnam, East Timor
SE Asia Countries see Honeywell Automation India Ltd for: Bangladesh Nepal Sri Lanka
EUROPE
Indonesia PT Honeywell Indonesia Phone: +(62) 21-535-8833 FAX: +(62) 21-5367 1008
Austria Honeywell Austria GmbH Phone: +43 (316)400123 FAX: +43 (316)40017
Honeywell Automation India Ltd. Honeywell Ltd. Phone:+(91) 6603-9400 Fax: +(91) 6603-9600
Belgium Honeywell SA/NV Phone:+32 (0)2728 24 07 FAX: +32 (0)2728 22 45
Denmark Honeywell A/S Phone: +(45) 39 55 55 55 FAX: +(45) 39 55 55 58
Spain Honeywell S.A. Phone: +34 (0)91313 61 00 FAX: +34 (0)91313 61 30
Finland Honeywell OY Phone: +358 (0)20752 2753 FAX: +358 (0) 20752 2751
Sweden Honeywell AB Phone: +(46) 8 775 55 00 FAX: +(46) 8 775 56 00
France Honeywell SA Phone: +33 (0)1 60198075 FAX: +33 (0)1 60198201
Switzerland Honeywell AG Phone: +41 18552448 FAX: +(41) 1 855 24 45
Germany Honeywell AG Phone: +49 (69)8064-299 FAX: +49 (69)806497336
Turkey Honeywell Turkey A.S. Phone: +90 216 578 71 00 FAX: +90 216 575 66 35
Hungary Honeywell Kft. Phone: +36-1-451 4300 FAX: +36-1-451 4343
Ukraine Honeywell Tel: +380-44-201 44 74 Fax: +380-44-201-44-75
Italy Honeywell S.p.A. Phone:+390292146307 FAX: +39 0292146377
United Kingdom Honeywell Control Systems Ltd. Phone: +44 (0)1344 655251 FAX: +44 (0) 1344 655554
The Netherlands Honeywell B.V. Phone: +31 (0) 20 5656200 FAX: +31 (0) 20 5656210 Norway Honeywell A/S Phone: (45) 39 55 55 55 Poland Honeywell Sp. zo.o Phone: +48-22-6060900 FAX: +48-22-6060901 Portugal Honeywell Portugal Lda Phone: +351 21 424 5000 FAX: +351 21 424 50 99 Romania Honeywell Bucharest Phone: +40 (0) 21 2316437 FAX: +40 (0) 21 2316439
Japan Honeywell Inc. Phone: +(81) 3 6730 7197 Fax: +(81) 3 6730 7228
Bulgaria Honeywell EOOD Phone: +(359) 2 40 20 900 FAX: +(359) 2 40 20 990
Russian Federation (RF), Honeywell Field Solutions Kievskaya str., 7, Moscow 121059, Russia Phone +7 (495) 796 98 60 Fax +7 (495) 797 99 64
Malaysia Honeywell Engineering Sdn Bhd Phone: +(603) 7958-4788 Fax: +(603) 7958-8922
Czech Republic Honeywell spol. s.r.o. Phone:+420 242 442 232 FAX: +420 242 442 131
Slovak Republic Honeywell s.r.o. Phone: +421-2-58247 410 FAX: +421-2-58247 415
MIDDLE EAST Abu Dhabi U A E Middle East Headquarters Honeywell Middle East Ltd. Phone: +971 2 4041246 FAX: +971 2 4432536 Sultanate of Oman Honeywell & Co Oman LLC Phone: +968 24 701153/ Ext.33 FAX +968 24 787351 Saudia Arabia Honeywell Turki Arabia Ltd Jubail Office Phone: +966-3-341-0140 Fax: +966-3-341-0216 Honeywell - ATCO Dammam Office Phone: 0096638304584 Fax: 0096638338059 Kuwait Honeywell Kuwait KSC Phone: +965 242 1327 to 30 Fax: +965 242 8315 And Phone: +965 326 2934/1821Fax: +965 326 1714
eZtrend QXe is a registered trademark of Honeywell International Inc. Specifications are subject to change without notice.
AFRICA Mediterranean & African Distributors Honeywell SpA Phone: +39 (02) 250 10 604 FAX: +39 (02) 250 10 659 South Africa (Republic of) and sub saharan Honeywell Southern Africa Honeywell S.A. Pty. Ltd. Phone: +27 11 6958000 FAX +27 118051504
NORTH AMERICA Canada Honeywell LTD Phone: 1-800-737-3360 FAX: 1-800-565-4130 USA Honeywell Process Solutions, Phone: 1-800-423-9883 Or 1-800-343-0228 Email:
[email protected]
SOUTH AMERICA Argentina Honeywell S.A.I.C. Phone: +(54-11) 4383-3637 FAX: +(54-11) 4325-6470 Brazil Honeywell do Brasil & Cia Phone: +(55-11) 7266-1900 FAX: +(55-11) 7266-1905 Chile Honeywell Chile, S.A. Phone: +(56-2) 233-0688 FAX: +(56-2) 231-6679 Mexico Honeywell S.A. de C.V. Phone: +(52) 55 5259-1966 FAX: +(52) 55 5570-2985 Puerto Rico Honeywell Inc. Phone: +(809) 792-7075 FAX: +(809) 792-0053 Trinidad Honeywell Inc. Phone: +(868) 624-3964 FAX: +(868) 624-3969 Venezuela Honeywell CA Phone: +(58-2) 238-0211 FAX: +(58-2) 238-3391
eZtrend® QXe
22
For More Information Learn more about how Honeywell’s eZtrend® QXe can provide flexible electronic data acquisition, visit our website www.honeywell.com/ps/hfs or contact your Honeywell account manager. Honeywell Process Solutions 1860 West Rose Garden Lane Phoenix, Arizona 85027 Tel: 1-800-423-9883 or 1-800-343-0228 www.honeywell.com/ps
43-TV-03-12 February 2011 © 2010-11 Honeywell International Inc.