Preview only show first 10 pages with watermark. For full document please download

F M Din T Uji

   EMBED


Share

Transcript

Models: ST7P-2A15S-ADC, ST7P-2A13T-ADC, ST7P-2A16T-ADC, ST7P-2A11N-ADC ST7P-2A16N-ADC FUJI MINIATURE DIN TIMER MANUAL Safety Precautions To ensure safe and proper operation, read this manual before installation, wiring, operation, maintenance, and inspection. Manual should be furnished to the final user. Original Edition May 2003 WARNING: Incorrect installation or operation may cause death or serious injury, and damage to equipment. It may also be necessay to use fail-safe measures if controlling a critical process or safety application. • Remove input power before installation, wiring, maintenance or inspection to prevent electrical shock. • Do not use this device if damaged when unpacked. • Only qualified personnal should perform installation, maintenance or inspection of this device. • To prevent fire, accidents and malfunction of this device, do not install in environments with high temperature, high humidity, dust, corrosive gases, water, direct sunlight or excessive vibration. Do no expose the case to solvents or corrosive substances such as benzene, strong acids or alkaloids. • Use this device within the range of its rated voltage and current. • Fire may occur if the power supply and load are incorrectly connected. • To prevent poor contact operation, keep timer from exposure to dust, concrete chips, iron filings and similar materials. • To prevent terminal malfunction, tighten periodically. • Never disassemble, modify or repair this device. • If replacing this device, be sure to dispose of it properly. Operation • Set the time within the range of the timing scale divisions. To make timer output a signal as soon as power is turned on, turn timer dial fully counterclockwise. • The timer dial can be turned while the timer is operating, but the time for that operation will not be correct. • Do not try to turn the timer dial outside the timing range. Turn dial carefully and do not force. • Do not remove the timer case, or the operating characteristics will change. Dimensions (Timer and Socket Shown Attached) Control ON 4 6 2 8 0 10 860 ST7 32.4 85.6 Set t i ng Dial 69 UP P ower I ndi cat or 4.5 O u tput In d icator Fuji Miniature DIN Timer Manual 1 Specifications Approvals UL file no.: Body - E44592, Socket - E90265; CSA file no.: LR20479; TÜV license no: R9551799 Repeat Accuracy Reset Time Maximum Operating Cycle ±01% at maximum setting time 0.1 second or less 1800 cycles/hour Operating Voltage Range 85-132VAC 20.4-26.4VDC ST7P-2A15S-ADC ST7P-2A13T-ADC ST7P-2A16T-ADC ST7P-2A11N-ADC ST7P-2A16N-ADC ST7P-2DE5S-ADC ST7P-2DE3T-ADC ST7P-2DE6T-ADC ST7P-2DE1N-ADC ST7P-2DE6N-ADC Operating Temperature Range Humidity -10 to +50°C (14 to 122°F) Contact Ratings 3A @ 240VAC resistive load, 1A @120VAC inductive load; 3A @ 30VDC resistive load, 0.5A @ 30VDC inductive load Approx. 1.2VA at 100VAC, approx. 1.5VA at 200VAC, 1.1W at 24VDC. 35 to 85% (no condensation) Power Consumption Insulation Resistance Surge Voltage* 100M at 500VDC insulation tested 3000 Volts Dielectric Strength 2000VAC 1 min. between current carrying part and noncurrent carrying part 2000VAC 1 min. between output contact and control circuit 1000VAC 1 min. between open contacts Vibration Malfunction durability: 10 to 55Hz, 0.5mm double amplitude Mechanical durability: 10 to 55Hz, 0.7mm double amplitude Shock Malfunction durability: 50m/s2 Mechanical durability: 1000m/s2 Life Expectancy Mechanical: 50 million operations Electrical: 500,000 operations Weight 36.288g (1.28 oz.) Dimensions - ST7P Body 5.7 2.2 0.5 All dimensions in mm 4 18.5 1 5 8 9 12 13 14 27.8 UP ON X1 4 X10 1.8 52.6 21 Dimensions - TP88X2 Body 32.4 6.8 4 1 Approx. 56.6 5 12 9 69 59 8 Panel Drilling 29 22.6 10.5 24.5 14 13 10.6 Wiring Diagram (- ) 1 4 5 8 9 12 13 14 Timing Diagram Sockets/Screw Terminal and Rail Mounting 4 8 1 5 (+ ) INPUT 2 2- 4 (M3, M4) 34 Terminal M3.5x8 Fuji Miniature DIN Timer Manual 12 14 9 13 Power (13-14) Timed NO (9-5) (12-8) Timed NC (9-1) (12-4) t