F132 Batch Controller With 2 Stage Control And

   EMBED


Share

Transcript

BATCH CONTROLLER WITH TWO STAGE CONTROL DATASHEET F132 - BATCH CONTROLLER AND RECEIPT PRINTER DRIVER Features • Receipt printing function after each batch. • Large display shows preset value and running batch value simultaneously. • Easy operation to enter a batch value, print an extra receipt and to control the process. • Count-up and count-down function available. • Self-learning overrun correction. • No-flow monitoring. • Selectable on-screen engineering units; volumetric or mass. • Operational temperature -40°C up to +80°C (-40°F up to 176°F). • Very compact design for panel mount, wall mount or field mount applications. • Rugged aluminum field mount enclosure IP67/NEMA4X. • Intrinsically Safe - ATEX and IECEx approval for gas and dust applications. • Explosion/flame proof II 2 GD EEx d IIB T5. • Lithium battery powered, 8 - 24V AC/DC or 115 - 230V AC power supply. • Sensor supply 3.2 / 8.2 / 12 / 24V DC. Signal output • Two configurable control outputs: for two-stage or one-stage control. Signal input Flow • Reed-switch. • NAMUR. • NPN/PNP pulse. • Sine wave (coil). • Active pulse signals. Status • Remote control: start. • Remote control: pause / stop. Applications • Batching of small and /or large quantities, single or repeating batches where printed information is requested. Alternative basic model: F030 or more sophisticated models: F130, F131, F136 and 0300 series. icenta Controls Ltd - UK distribution partner for Fluidwell displays Tel: +44 (0)1722 741890 Email: [email protected] www.icenta.co.uk For remote control, two inputs are available to start, pause and stop the batch process. General information Introduction The F132 is a straight forward two stage batch controller with the unique function to send a “print receipt” command to a printer after every batch. The operator can easily enter a batch quantity, send an extra “print receipt” command or execute repeating batches. During the batch, the preset value is displayed as well as the batched (or remaining) quantity including the units of measurement. The automatic selflearning overrun correction ensures an accurate result after each batch. A wide selection of options further enhances the capabilities of this model, wich includes Intrinsic Safety. No-flow If there is a predefined time-out in the input signal, the no-flow alarm will be triggered. The F132 goes in pause-mode and the display will show: NO FLOW. Printer communication The “print receipt” command is processed through the ASCII data communication link (RS232 / RS485). Receipt printing functionality remains available for the Intrinsically Safe version (TTL). Display Hazardous areas The display has large 17mm (0.67”) and 8mm (0.31”) digits which show the batched quantity and the preset value simultaneously. On-screen engineering units are easily configured from a comprehensive menu. A seven digit resettable "day total" is available as well as an eleven digit non-resettable accumulated total. All values are backed-up in EEPROM memory every minute. This model has been ATEX and IECEx certified Intrinsically Safe for gas and dust applications, with an allowed operational temperature of -40°C to +70°C (-40°F to +158°F). A flame proof enclosure with ATEX certification offers the rating II 2 GD EEx d IIB T5. Enclosures All enclosures are ATEX and IECEx approved. As standard the F132 is supplied in an GRP panel mount enclosure, which can be converted to an IP67 / NEMA 4X GRP field mount enclosure by the addition of a back case. Most popular is our rugged aluminum field mount enclosure. Configuration All configuration settings are accessed via a simple operator menu which can be pass-code protected. Each setting is clearly indicated with an alphanumerical description, which avoides confusing abbreviations and baffling codes. Once familiar with one F-series product, you will be able to program all models in the series without a manual. All settings are safely stored in EEPROM memory in the event of sudden power failure. Overview application F132 RS232 / RS485 / TTL ASCII data to printer Control outputs External START External PAUSE / STOP Two outputs are available which can be configured to operate as two stage control for large batch quantities or as one stage control for smaller batches. The output signals can be passive NPN, active PNP or isolated electromechanical relays. Control output R1 Control output R2 Flowmeter input Signal input The F132 accepts most pulse input signals for volumetric flow or mass flow measurement. 2 F132 0.9" 0.9" 1 2 / "NPT 15mm 38mm 1 2 / "NPT 15mm HT 1 /2"NPT HU 30mm (1.18") 30mm (1.18") 1 2 / "NPT HJ 1.18" 1.18" HK Flat bottom, no holes available. 4 x M20 x 1.5 HV HZ 3 + = = P: PNP - + Ø22 ( 7/8") Ø22 ( 7/8") Ø22 ( 7/8") Display example - 90 x 40mm (3.5” x 1.6”) PB / PC: battery powered Internal long life Lithium battery (terminals GND - 1 - 2 are not available) PM: 115 - 230V AC + - - + + + P: reed switch / NPN P: active signal = + OR: mech. relay + PF: 24V DC = OR: mech. relay OT: passive trans. - START 12 + 14 13 11 10 9 P: coil 8 7 PX: 8 - 30V DC P: namur Ø12 PF: 24V AC + 24mm 24mm 36mm 36mm + HH - 6 x M12 Ø20 + 12mm 12mm - Ø20 OT: passive trans. HG 6 25mm 25mm 5 Ø22 ( 7/8") OA: active 24V DC HF PD - XI: 16 - 30V DC HP Ø16 PD: 8 - 24V DC M20 x 1,5 Ø20 START INPUT 30mm 30mm FLOWMETER INPUT M20 x 1,5 PG9 4 Ø16 POWER SUPPLY STANDARD STOP 15 + 16 STOP INPUT GRP 3 HO 17 112 mm (4.40") OA: active 24V DC M20 x 1,5 18 19 20 21 22 Ø 7mm (0.27") 2 HN HE CONTROL OUTPUT R1 HM 22,50mm 60 mm (2.36") 23 Aluminum & GRP field / wall mount enclosures 1 24mm 24mm 36mm 36mm 24 panel cut-out GND 12mm 12mm 25 26 27 A A DTR +12V RXD CT: TTL Intrinsically Safe CI: RS485 - 4 wire 28 RXD CH: RS485 - 2 wire DTR +12V CB: RS232 TXD B B TXD 29 Y 30 PRINTER COMMUNICATION 98 (3.86") 115 (4.53") PD: 8 - 24V AC M20 x 1,5 M16 x 1,5 22,50mm (0.9") Aluminum CONTROL OUTPUT R2 25mm HA 22,50mm 30mm 30mm 22,50mm 75 mm (2.95") POWER SUPPLY OPTIONAL 25mm Ø 7mm (0.27") 17mm 30mm 30mm 22,50mm 130 mm (5.12") 14mm 22,50mm M20 x 1,5 22,50mm M16 x 1,5 17mm HB & HC enclosures 22,50mm (0.9") 14mm PG9 130 mm (5.12") + F132 29 mm (1.14") 15mm 120 mm (4.72") 31 mm (1.22") + 16mm 120 mm (4.72") Z 31 Dimensions enclosures Terminal connections Aluminum & GRP panel mount enclosure HD Typical wiring diagram F132-P-CH-OT-PB-(PX) TERMINAL CONNECTORS F100-series Typical wiring diagram F132-P-CH-OT-PX 8 - 24V AC / DC POWER SUPPLY (BASIC) TERMINAL CONNECTORS F100-series BATTERY POWERED ASCII data printer communication type CH: RS485 - 2 wire A 29 A 28 29 B Common ground Flowmeter input type: P pulse 9 16 15 14 13 11 Common ground Power supply PX: 8 - 30V DC Power supply type PX: 8 - 30V DC (not used in this example) e.g. relay or solenoid Main supply 8 Common ground Flowmeter input type: P pulse Signal Common ground 7 Main supply 8 Common ground 10 Signal Supply * 10 11 Circuit depends on type of signal Supply * Logic input: START 12 + 3.2V 1M low-pass filter Logic input: PAUSE / STOP 9 26 16 15 14 Logic input: START 7 Circuit depends on type of signal Common ground Common ground 13 + 3.2V 1M low-pass filter + 3.2V 1M low-pass filter 12 Common ground Logic input: PAUSE / STOP 8 - 30V DC e.g. relay or solenoid 6 6 + Control output R1 type OT: passive transistor 5 Control output R2 type OT: passive transistor 4 4 Common ground 3 Common ground Common ground Control outputs type OT: passive transistor e.g. relay or solenoid 3 e.g. relay or solenoid - 5 8 - 24V DC Common ground - + 3.2V 1M low-pass filter Common ground + Common ground 26 27 B 28 ASCII data printer communication type CH: RS485 - 2 wire Please note: PX may be used in combination with the battery! PX will power the unit; the battery will be disabled automatically untill power is disconnected). *Supply voltage: 1.2 / 3.2V DC to sensor *Supply voltage: 1.2 / 3.2V DC to sensor 4 F132 Typical wiring diagram F132-P-CB-OA-PD Typical wiring diagram F132-P-CI-OR-PM 24V AC / DC POWER SUPPLY 29 29 28 Control output R1 type OA: active 24V DC pulse + 4 Control output R2 type OA: active 24V DC pulse 16 15 2 2 3 3 e.g. relay or solenoid Main supply 8 - 24V AC 0 L1 Power supply type PM: 115 - 230V AC N Earth 8 - 24V DC - Power supply type PD: 8 - 24V AC / DC + 1 13 Control outputs type OR: mechanic relay Common ground Earth *Supply voltage: 3.2 / 8.2 / 12 / 24V DC to sensor F132 10 e.g. relay or solenoid e.g. relay Main supply Common ground Power supply PX: 8 - 30V DC (not used in this example) 6 7 Common ground e.g. relay 5 Main supply Power supply PX: 8 - 30V DC (not used in this example) 6 + Common ground 11 Common ground Flowmeter input type: P pulse 5 8 Common ground Signal 4 Main supply Supply * 9 Circuit depends on type of signal Flowmeter input type: P pulse Logic input: START 12 Common ground Logic input: PAUSE / STOP 8 Logic input: START 11 10 Signal Common ground T: + 3.2V 1M low-pass filter 26 27 26 Common ground Supply * Common ground T: Logic input: PAUSE / STOP 9 Circuit depends on type of signal Common ground + 3.2V 1M low-pass filter 7 + 3.2V 1M low-pass filter ASCII data printer communication type CI: RS485 - 4 wire 1 Common ground 115 - 230V AC POWER SUPPLY 0 + 3.2V 1M low-pass filter Common ground 16 Common ground 15 DTR 12V A 13 RXD B 12 TXD Y 28 ASCII data printer communication type CB: RS232 Z 31 TERMINAL CONNECTORS F100-series 30 TERMINAL CONNECTORS F100-series *Supply voltage: 3.2 / 8.2 / 12 / 24V DC to sensor 5 Hazardous area applications Certificate of conformity KEMA 03ATEX1074 X • IECEx DEK 11.0042X The F132-XI has been certified according ATEX and IECEx by DEKRA for use in Intrinsically Safe applications with an ambient temperature of -40°C to +70°C (-40°F to +158°F). • The ATEX markings for gas and dust applications are: II 1 G Ex ia IIB/IIC T4 Ga II 1 D Ex ia IIIC T100 ¡C Da IP6X. • The IECEx markings for gas and dust applications are: Ex ia IIC/IIB T4 Ga and Ex ia IIIC T100 ¡C Da IP6X. Besides the I.S. power supplies for the control outputs, it is allowed to connect up to two I.S. power supplies in IIB/IIIC applications or one in IIC applications. Consult the certificate for the maximum input and output values of the circuits. Full functionality of the F132 remains available, including two stage control and Modbus communication (type CT). Power supply type PD-XI offers a 8.2V sensor supply e.g. for one Namur sensor. A flame proof enclosure with rating ATEX II 2 GD EEx d IIB T5 is available as well. Please contact your supplier for further details. 6 F132 Configuration example IIB / IIIC and IIC - F132-P-(CT)-OT-PX-XI - Battery powered unit HAZARDOUS AREA TERMINAL CONNECTORS F100-series SAFE AREA RXD Uo=max 30V 28 TXD 29 ASCII data communication type CT: TTL Please note: communciation type CT is not allowed in IIC applications. + 27 Po=max 850mW For example: MTL5051 26 Common ground Printer - DTR +12V Io=max 250mA ISOLATOR: I.S. Certified Isolator TTL to RS232 / RS422 / TTL Ci is negligibly small Logic input: START 15 Logic input: PAUSE / STOP 11 Supply * Flowmeter input type: P pulse Main supply 8 Common ground 7 Common ground 10 Signal Ci is negligibly small 9 Circuit depends on type of signal Common ground Ci is negligibly small 14 + 3.2V 1M low-pass filter 13 Common ground 12 + 3.2V 1M low-pass filter 16 * Note: Communication only allowed when configured as IIB / IIIC. Power supply type PX: 8 - 30V DC (not used in this example) Please note: type PX may be used in combination with the battery (type PC), but only in IIB applications! PX will power the unit; the battery will be disabled automatically till power is disconnected. 5 4 3 POWER SUPPLY Uo=max 30V e.g. MTL 5525 Io=max 100mA or SWITCH INTERFACE Po=max 750mW e.g. MTL 5511 e.g. relay Note: above values are safety values. Consult the technical specification for operational values. 7 - Control output R2 type OT: passive transistor * Note sensor supply voltage: 1.2V DC for coil sensors or 3.2V DC for other pulse sensors. F132 Po=max 750mW e.g. relay Ci is negligibly small POWER SUPPLY e.g. MTL 5525 or SWITCH INTERFACE e.g. MTL 5511 - Common ground Control output R1 type OT: passive transistor Uo=max 30V Io=max 100mA + 6 + Common ground e.g. relay Ci is negligibly small e.g. relay Configuration example IIB / IIIC and IIC - F132-P-(CT)-OT-PX-XI - Basic power supply 8 - 30V DC HAZARDOUS AREA TERMINAL CONNECTORS F100-series SAFE AREA RXD Uo=max 30V 28 TXD 29 ASCII data communication type CT: TTL Please note: communciation type CT is not allowed in IIC applications. + 27 Po=max 850mW For example: MTL5051 26 Common ground Printer - DTR +12V Io=max 250mA ISOLATOR: I.S. Certified Isolator TTL to RS232 / RS422 / TTL Ci is negligibly small Logic input: START 15 Logic input: PAUSE / STOP 11 Supply * Flowmeter input type: P pulse Common ground 9 10 Signal Main supply 8 Circuit depends on type of signal Common ground Ci is negligibly small 14 + 3.2V 1M low-pass filter 13 Common ground 12 + 3.2V 1M low-pass filter 16 * Note: Communication only allowed when configured as IIB / IIIC. Ci is negligibly small + 7 5 4 3 POWER SUPPLY Uo=max 30V e.g. MTL 5525 Io=max 100mA or SWITCH INTERFACE Po=max 750mW e.g. MTL 5511 e.g. relay Note: above values are safety values. Consult the technical specification for operational values. - Control output R2 type OT: passive transistor POWER SUPPLY e.g. MTL 5525 or SWITCH INTERFACE e.g. MTL 5511 Po=max 750mW e.g. relay Ci is negligibly small Uo=max 30V Io=max 100mA For example MTL 5525 - Common ground Control output R1 type OT: passive transistor Po=max 750mW POWER SUPPLY + 6 + Common ground e.g. relay Ci is negligibly small Uo=max 30V Io=max 100mA - Common ground Power supply type PX: 8 - 30V DC e.g. relay * Note sensor supply voltage: 1.2V DC for coil sensors or 3.2V DC for other pulse sensors. 8 F132 Configuration example IIB / IIIC and IIC - F132-P-(CT)-OT-PD-XI - Power supply 16 - 30V DC HAZARDOUS AREA TERMINAL CONNECTORS F100 - series SAFE AREA RXD Uo=max 30V 28 TXD 29 ASCII data communication type CT: TTL Please note: communciation type CT is not allowed in IIC applications. + 27 26 Common ground Po=max 850mW Printer For example: MTL5051 - DTR +12V Io=max 250mA ISOLATOR: I.S. Certified Isolator TTL to RS232 / RS422 / TTL Ci is negligibly small Logic input: START 15 Logic input: PAUSE / STOP 11 Supply * Common ground 10 Signal Ci is negligibly small Flowmeter input type: P pulse 9 Circuit depends on type of signal Common ground Ci is negligibly small 14 + 3.2V 1M low-pass filter 13 Common ground 12 + 3.2V 1M low-pass filter 16 * Note: Communication only allowed when configured as IIB / IIIC. Control output R1 type OT: passive transistor 4 e.g. relay POWER SUPPLY Uo=max 30V e.g. MTL 5525 or Io=max 100mA SWITCH INTERFACE Po=max 750mW e.g. MTL 5511 Control output R2 type OT: passive transistor e.g. relay 2 3 Ci is negligibly small - 6 5 e.g. relay Common ground POWER SUPPLY e.g. MTL 5525 or SWITCH INTERFACE Po=max 750mW e.g. MTL 5511 Uo=max 30V Io=max 100mA + Common ground + e.g. relay Ci is negligibly small Power supply type PD: 16 - 30V DC (please note: PD and battery supply (type PC) is NOT allowed in IIC applications). 0 Uo=max 30V Io=max 100mA - Common ground 1 + Main supply Po=max 750mW POWER SUPPLY For example MTL 5525 Note: above values are safety values. Consult the technical specification for operational values. * Note power supply type PD: the supply voltage to pulse sensors is maximum 8.7V (Uo=max 8.7V Io=max 25mA Po=max 150mW). F132 9 Technical specification Casing General General Window Sealing Control keys Display Type Dimensions Digits Refresh rate Option ZB Note ZB High intensity reflective numeric and alphanumeric LCD, UV-resistant. 90 x 40mm (3.5” x 1.6”). Seven 17mm (0.67") and eleven 8mm (0.31") digits. Various symbols and measuring units. User definable: 8 times/sec. - 1 time/30 secs. Transflective LCD with green LED backlight. Good readings in full sunlight and darkness. Only available for safe area applications. Aluminum wall / field mount enclosures General Dimensions Weight Type HA Type HM Type HN Type HO Type HP Type HT Type HU Type HV Type HZ Operating temperature Standard unit -40°C to +80°C (-40°F to +176°F). Intrinsically Safe -40°C to +70°C (-40°F to +158°F). Power requirements Type PB Long life Lithium battery - life-time depends upon settings and configuration - up to 5 years. Type PC Intrinsically Safe long life lithium battery - life-time depends upon settings and configuration - up to 5 years. Type PD 8 - 24V AC / DC ± 10%. Power consumption max. 10 Watt. Intrinsically Safe: 16 - 30V DC; power consumption max. 0.75 Watt. Type PF 24V AC / DC ± 10%. Power consumption max. 15 Watt. Type PM 115 - 230V AC ± 10%. Power consumption max. 15 Watt. Type PX 8 - 30V DC. Power consumption max. 0.5 Watt. Type ZB Internally powered, only available with type PD / PF / PM. Power consumption max. 1 Watt. Note PB/PF/PM Not availble Intrinsically Safe. Note PF/PM The total consumption of the sensors and outputs may not exceed 400mA @ 24V. Note For Intrinsically Safe applications, consult the safety values in the certificate. Note Type PD Type PD-XI Type PF / PM General Dimensions Weight Type HD Type HE Type HF Type HG Type HH Type HJ Type HK Dimensions Panel cut-out Type HB 3.2V DC for pulse signals and 1.2V DC for coil pick-up. This is not a real sensor supply. Only suitable for sensors with a very low power consumption like coils (sine wave) and reed-switches. 1.2 / 3.2 / 8.2 / 12 / 24V DC - max. 50mA @ 24V DC. 1.2 / 3.2 / 8.2V DC - max. 7mA @ 8.2V DC and mains power supply voltage (as connected to terminal 1). 1.2 / 3.2 / 8.2 / 12 / 24V DC - max. 400mA @ 24V DC. Weight Type HC Weight Removable plug-in terminal strip. Wire max. 1.5mm2 and 2.5mm2. Dimensions Weight Type HS Data protection Pass-code 130 x 120 x 60mm (5.12" x 4.72" x 2.36") - W x H x D. 115 x 98mm (4.53" x 3.86") L x H. Die-cast aluminum panel mount enclosure IP65 / NEMA 4X. 600 gr. GRP panel mount enclosure IP65 / NEMA 4X, UV-resistant and flame retardant. 450 gr. ABS wall / field mount enclosures General Type GRP wall/field mount enclosure IP67 / NEMA 4X, UV-resistant and flame retardant. 130 x 120 x 75mm (5.12" x 4.72" x 2.95") - W x H x D. 600 gr. Cable entry: no holes. Cable entry: 2 x Ø 16mm and 1 x Ø 20mm. Cable entry: 1 x Ø 22mm (7/8"). Cable entry: 2 x Ø 20mm. Cable entry: 6 x Ø 12mm. Cable entry: 3 x Ø 22mm (7/8"). Flat bottom, cable entry: no holes. Panel mount enclosures Terminal connections Type Die-cast aluminum wall/field mount enclosure IP67 / NEMA 4X with 2-component UV-resistant coating. 130 x 120 x 75mm (5.12" x 4.72" x 2.95") - W x H x D. 1100 gr. Cable entry: 2 x PG9 and 1 x M20. Cable entry: 2 x M16 and 1 x M20. Cable entry: 1 x M20. Cable entry: 2 x M20. Cable entry: 6 x M12. Cable entry: 1 x 1/2" NPT. Cable entry: 3 x 1/2" NPT. Cable entry: 4 x M20. Cable entry: no holes. GRP wall / field mount enclosures Sensor excitation Type PB/PC/PX Polycarbonate window. Silicone. Three industrial micro-switch keys. UV-resistant silicone keypad. Silicone free ABS wall/field mount enclosure IP65 with EPDM and PE sealings. UV-resisitant polyester keypad (old HD enclosure). 130 x 114 x 71mm (5.1" x 4.5" x 2.8") - W x H x D. 450 gr. Cable entry: no holes. EEPROM backup of all settings. Backup of running totals every minute. Data retention at least 10 years. Configuration settings can be pass-code protected. 10 F132 Hazardous area Intrinsically Safe (Type XI) ATEX certification IECEx certification Ambient Ta Operational Operator functions II 1 G Ex ia IIB/IIC T4 Ga. II 1 D Ex ia IIIC T100 °C Da IP6X. Ex ia IIC/IIB T4 Ga. Ex ia IIIC T100 °C Da IP6X. -40°C to +70°C (-40°F to +158°F). Displayed functions Explosion proof (Type XF) ATEX certification Dimensions Weight Preset and total II 2 GD EEx d IIB T5. 300 x 250 x 200mm (11.8" x 9.9" x 7.9") L x H x D. Appr. 15kg. Digits Units Decimals Note Environment Electromagnetic Compliant ref: EN 61326 (1997), EN 61010-1 (1993). compatibility Digits 11 digits. Units / decimals According to selection for total. Note Can not be reset to zero. Signal inputs Frequency K-Factor Low-pass filter Option ZF Coil / sine wave (minimum 20mVpp or 80mVpp sensitivity selectable), NPN/PNP, open collector, reedswitch, Namur, active pulse signals 8 - 12 and 24V DC. Minimum 0Hz - maximum 7kHz for total and flow rate. Maximum frequency depends on signal type and internal low-pass filter. E.g. reed switch with low-pass filter: max. frequency 120Hz. 0.000010 - 9,999,999 with variable decimal position. Available for all pulse signals. coil sensitivity 10mVpp. Accessories Mounting accessories ACF02 ACF05 ACF06 ACF07 ACF08 ACF09 ACF10 Logic inputs Function Type Duration Two terminal inputs to start, pause and stop the batch process. Internally pulled-up switch contact - NPN. Minimum pulse duration 100msec. Type OR Type OT Stainless steel wall mounting kit. Stainless steel pipe mounting kit (worm gear clamps not included). Two stainless steel worm gear clamps Ø 44 - 56mm. Two stainless steel worm gear clamps Ø 58 - 75mm. Two stainless steel worm gear clamps Ø 77 - 95mm. Two stainless steel worm gear clamps Ø 106 - 138mm. Customized Grevopal tagplates for ACF02 and ACF05, including stainless steel screws. Dimension: 95mm x 12.5mm (3.75” x 0.50”). Cable gland accessories ACF20 ACF25 ACF26 ACF27 ACF28 ACF29 ACF32 ACF33 ACF34 ACF35 ACF39 ACF40 Signal outputs Control / pulse output Function Type OA 7 digits. L, m3, GAL, USGAL, kg, lb, bbl, no unit. 0 - 1 - 2 or 3. Total can be reset to zero. Accumulated total Flowmeter Type P • Preset value - can be entered by the operator. • Batched quantity or remaining quantity. • Total and accumulated total. • Nr. of batches. • Reprint the last receipt. • No-flow alarm. User defined: batch process one or two stage control. Two active 24V DC transistor outputs (PNP); max. 50mA per output (requires PD, PF or PM). Two electro-mechanical relay outputs (N.O.) - isolated; max. switch power 230V AC - 0.5A per relay (requires PF or PM). Two passive transistor outputs (NPN) - not isolated. Max. 50V DC - 300mA per output. For HA enclosure, includes O-rings. For HE enclosure, includes locknuts and O-rings. For HF enclosure, includes locknuts and O-rings. For HG enclosure, includes locknuts and O-rings. For HH enclosure, includes locknuts and O-rings. For HJ enclosure, includes locknuts and O-rings. For HM enclosure, includes O-rings. For HN enclosure, includes O-rings. For HO enclosure, includes O-rings. For HP enclosure, includes O-rings. For HT enclosure, includes O-rings. For HU enclosure, includes O-rings. Blind plug accessories ACF50 ACF55 ACF56 ACF57 ACF58 ACF59 ACF62 ACF63 ACF64 ACF65 ACF69 ACF70 Printer communication option Function Protocol Speed Type CB H Type C Type CI Type CT F132 Send a “print receipt” command after every batch. ASCII data. 1200 - 2400 - 4800 - 9600 baud. RS232 RS485 2-wire RS485 4-wire TTL Intrinsically Safe. 11 For HA enclosure, includes O-rings. For HE enclosure, includes locknuts and O-rings. For HF enclosure, includes locknuts and O-rings. For HG enclosure, includes locknuts and O-rings. For HH enclosure, includes locknuts and O-rings. For HJ enclosure, includes locknuts and O-rings. For HM enclosure, includes O-rings. For HN enclosure, includes O-rings. For HO enclosure, includes O-rings. For HP enclosure, includes O-rings. For HT enclosure, includes O-rings. For HU enclosure, includes O-rings. Ordering information Standard configuration: F132-P-AX-CX-EX-HC-IX-OT-PX-TX-XX-ZX. Ordering information: F132 -_ -AX -C _ Flowmeter input signal P -EX -H _ -IX -O _ -P _ -TX -X _ Pulse input: coil, npn, pnp, namur, reed-switch. Analog output signal AX No analog output. Printer communication CB H C CI CT CX Communication RS232 - ASCII data. Communication RS485 - 2-wire - ASCII data. Communication RS485 - 4-wire - ASCII data. Intrinsically Safe TTL - ASCII data. No printer communication. Flow equations EX No flow equations. Panel mount enclosures - IP65 / NEMA4X HB HC Aluminum enclosure. GRP enclosure. GRP field / wall mount enclosures - IP67 / NEMA4X HD HE HF HG HH HJ HK Cable entry: no holes. Cable entry: 2 x Ø 16mm & 1 x Ø 20mm. Cable entry: 1 x Ø 22mm (7/8”). Cable entry: 2 x Ø 20mm. Cable entry: 6 x Ø 12mm. Cable entry: 3 x Ø 22mm (7/8”). Flat bottom, cable entry: no holes. Aluminum field / wall mount enclosures - IP67 / NEMA4X HA HM HN HO HP HT HU HV HZ Cable entry: 2 x PG9 + 1 x M20. Cable entry: 2 x M16 + 1 x M20. Cable entry: 1 x M20. Cable entry: 2 x M20. Cable entry: 6 x M12. Cable entry: 1 x 1/2”NPT. Cable entry: 3 x 1/2”NPT. Cable entry: 4 x M20. Cable entry: no holes. ABS field / wall mount enclosures - IP65 HS Silicone free ABS field enclosure – Cable entry: no holes (old HD enclosure). Additional inputs IX No additional input. Outputs OA OR OT Two active transistor outputs - requires PD, PF or PM. Two mechanical relay outputs - requires PF or PM. Two passive transistor outputs - standard configuration. Power supply PB PC PD PF PM PX Lithium battery powered. Lithium battery powered - Intrinsically Safe. 8 - 24V AC/DC + sensor supply - with XI: 16 - 30V DC. 24V AC/DC + sensor supply. 115 - 230V AC + sensor supply. Basic power supply 8 - 30V DC (no real sensor supply). Temperature input signal TX No temperature input signal. Hazardous area XI XF XX Intrinsically Safe, according ATEX and IECEx. EExd enclosure - 3 keys. Safe area only. Other options ZB ZF ZX Backlight - requires PD, PF or PM. Coil input 10mVpp. No options. The bold marked text contains the standard configuration. Available Intrinsically Safe. icenta Controls Ltd, North Station Yard, Warminster Road, Wilton, Salisbury, SP2 0AT, UK Tel: +44 (0)1722 741890 Lo-Call: 0845 895 1020 Fax: +44 (0)1722 742031 Email: [email protected] www.icenta.co.uk -Z _