BATCH CONTROLLER WITH TWO STAGE CONTROL
DATASHEET F132 - BATCH CONTROLLER
AND RECEIPT PRINTER DRIVER
Features
• Receipt printing function after each batch. • Large display shows preset value and running batch value simultaneously. • Easy operation to enter a batch value, print an extra receipt and to control the process. • Count-up and count-down function available. • Self-learning overrun correction. • No-flow monitoring. • Selectable on-screen engineering units; volumetric or mass. • Operational temperature -40°C up to +80°C (-40°F up to 176°F). • Very compact design for panel mount, wall mount or field mount applications. • Rugged aluminum field mount enclosure IP67/NEMA4X. • Intrinsically Safe - ATEX and IECEx approval for gas and dust applications. • Explosion/flame proof II 2 GD EEx d IIB T5. • Lithium battery powered, 8 - 24V AC/DC or 115 - 230V AC power supply. • Sensor supply 3.2 / 8.2 / 12 / 24V DC.
Signal output
• Two configurable control outputs: for two-stage or one-stage control.
Signal input Flow • Reed-switch. • NAMUR. • NPN/PNP pulse. • Sine wave (coil). • Active pulse signals. Status • Remote control: start. • Remote control: pause / stop.
Applications
• Batching of small and /or large quantities, single or repeating batches where printed information is requested. Alternative basic model: F030 or more sophisticated models: F130, F131, F136 and 0300 series.
icenta Controls Ltd - UK distribution partner for Fluidwell displays Tel: +44 (0)1722 741890 Email:
[email protected]
www.icenta.co.uk
For remote control, two inputs are available to start, pause and stop the batch process.
General information Introduction The F132 is a straight forward two stage batch controller with the unique function to send a “print receipt” command to a printer after every batch. The operator can easily enter a batch quantity, send an extra “print receipt” command or execute repeating batches. During the batch, the preset value is displayed as well as the batched (or remaining) quantity including the units of measurement. The automatic selflearning overrun correction ensures an accurate result after each batch. A wide selection of options further enhances the capabilities of this model, wich includes Intrinsic Safety.
No-flow If there is a predefined time-out in the input signal, the no-flow alarm will be triggered. The F132 goes in pause-mode and the display will show: NO FLOW.
Printer communication The “print receipt” command is processed through the ASCII data communication link (RS232 / RS485). Receipt printing functionality remains available for the Intrinsically Safe version (TTL).
Display
Hazardous areas
The display has large 17mm (0.67”) and 8mm (0.31”) digits which show the batched quantity and the preset value simultaneously. On-screen engineering units are easily configured from a comprehensive menu. A seven digit resettable "day total" is available as well as an eleven digit non-resettable accumulated total. All values are backed-up in EEPROM memory every minute.
This model has been ATEX and IECEx certified Intrinsically Safe for gas and dust applications, with an allowed operational temperature of -40°C to +70°C (-40°F to +158°F). A flame proof enclosure with ATEX certification offers the rating II 2 GD EEx d IIB T5.
Enclosures All enclosures are ATEX and IECEx approved. As standard the F132 is supplied in an GRP panel mount enclosure, which can be converted to an IP67 / NEMA 4X GRP field mount enclosure by the addition of a back case. Most popular is our rugged aluminum field mount enclosure.
Configuration All configuration settings are accessed via a simple operator menu which can be pass-code protected. Each setting is clearly indicated with an alphanumerical description, which avoides confusing abbreviations and baffling codes. Once familiar with one F-series product, you will be able to program all models in the series without a manual. All settings are safely stored in EEPROM memory in the event of sudden power failure.
Overview application F132
RS232 / RS485 / TTL ASCII data to printer
Control outputs
External START External PAUSE / STOP
Two outputs are available which can be configured to operate as two stage control for large batch quantities or as one stage control for smaller batches. The output signals can be passive NPN, active PNP or isolated electromechanical relays.
Control output R1
Control output R2
Flowmeter input
Signal input The F132 accepts most pulse input signals for volumetric flow or mass flow measurement.
2
F132
0.9"
0.9"
1 2
/ "NPT
15mm
38mm
1 2
/ "NPT
15mm
HT
1
/2"NPT
HU
30mm (1.18") 30mm (1.18")
1 2
/ "NPT
HJ
1.18" 1.18"
HK
Flat bottom, no holes available.
4 x M20 x 1.5
HV
HZ
3 +
=
=
P: PNP
-
+
Ø22 ( 7/8") Ø22 ( 7/8") Ø22 ( 7/8")
Display example - 90 x 40mm (3.5” x 1.6”)
PB / PC: battery powered Internal long life Lithium battery (terminals GND - 1 - 2 are not available)
PM: 115 - 230V AC
+
-
-
+
+
+
P: reed switch / NPN
P: active signal
=
+ OR: mech. relay
+
PF: 24V DC
=
OR: mech. relay
OT: passive trans.
-
START
12
+
14
13
11
10
9 P: coil
8
7 PX: 8 - 30V DC
P: namur
Ø12
PF: 24V AC
+
24mm 24mm 36mm 36mm
+
HH
-
6 x M12 Ø20
+
12mm 12mm
-
Ø20
OT: passive trans.
HG 6
25mm 25mm
5
Ø22 ( 7/8")
OA: active 24V DC
HF
PD - XI: 16 - 30V DC
HP Ø16
PD: 8 - 24V DC
M20 x 1,5 Ø20 START INPUT
30mm 30mm
FLOWMETER INPUT
M20 x 1,5 PG9
4
Ø16
POWER SUPPLY STANDARD
STOP
15
+
16
STOP INPUT
GRP
3
HO 17
112 mm (4.40")
OA: active 24V DC
M20 x 1,5
18
19
20
21
22
Ø 7mm (0.27")
2
HN HE
CONTROL OUTPUT R1
HM 22,50mm
60 mm (2.36")
23
Aluminum & GRP field / wall mount enclosures
1
24mm 24mm 36mm 36mm
24
panel cut-out
GND
12mm 12mm
25
26
27
A
A
DTR +12V
RXD
CT: TTL Intrinsically Safe
CI: RS485 - 4 wire
28
RXD CH: RS485 - 2 wire
DTR +12V
CB: RS232
TXD
B
B
TXD
29
Y
30
PRINTER COMMUNICATION
98 (3.86")
115 (4.53")
PD: 8 - 24V AC
M20 x 1,5 M16 x 1,5 22,50mm (0.9")
Aluminum
CONTROL OUTPUT R2
25mm
HA
22,50mm
30mm 30mm 22,50mm
75 mm (2.95")
POWER SUPPLY OPTIONAL
25mm Ø 7mm (0.27")
17mm
30mm 30mm 22,50mm
130 mm (5.12")
14mm
22,50mm
M20 x 1,5
22,50mm
M16 x 1,5
17mm
HB & HC enclosures
22,50mm (0.9")
14mm
PG9 130 mm (5.12")
+
F132 29 mm (1.14")
15mm
120 mm (4.72")
31 mm (1.22")
+
16mm
120 mm (4.72")
Z
31
Dimensions enclosures Terminal connections
Aluminum & GRP panel mount enclosure
HD
Typical wiring diagram F132-P-CH-OT-PB-(PX) TERMINAL CONNECTORS F100-series
Typical wiring diagram F132-P-CH-OT-PX 8 - 24V AC / DC POWER SUPPLY (BASIC)
TERMINAL CONNECTORS F100-series
BATTERY POWERED
ASCII data printer communication type CH: RS485 - 2 wire
A
29
A
28
29
B
Common ground
Flowmeter input type: P pulse
9
16 15 14 13 11
Common ground
Power supply PX: 8 - 30V DC
Power supply type PX: 8 - 30V DC (not used in this example) e.g. relay or solenoid
Main supply
8
Common ground
Flowmeter input type: P pulse
Signal
Common ground
7
Main supply
8
Common ground
10
Signal
Supply *
10
11
Circuit depends on type of signal
Supply *
Logic input: START
12
+ 3.2V 1M low-pass filter
Logic input: PAUSE / STOP
9
26 16 15 14
Logic input: START
7
Circuit depends on type of signal
Common ground
Common ground
13
+ 3.2V 1M low-pass filter
+ 3.2V 1M low-pass filter
12
Common ground
Logic input: PAUSE / STOP
8 - 30V DC e.g. relay or solenoid
6
6
+
Control output R1 type OT: passive transistor
5
Control output R2 type OT: passive transistor
4
4
Common ground
3
Common ground
Common ground
Control outputs type OT: passive transistor
e.g. relay or solenoid
3
e.g. relay or solenoid
-
5
8 - 24V DC Common ground
-
+ 3.2V 1M low-pass filter
Common ground
+
Common ground
26
27
B
28
ASCII data printer communication type CH: RS485 - 2 wire
Please note: PX may be used in combination with the battery! PX will power the unit; the battery will be disabled automatically untill power is disconnected).
*Supply voltage: 1.2 / 3.2V DC to sensor
*Supply voltage: 1.2 / 3.2V DC to sensor
4
F132
Typical wiring diagram F132-P-CB-OA-PD
Typical wiring diagram F132-P-CI-OR-PM
24V AC / DC POWER SUPPLY
29
29 28
Control output R1 type OA: active 24V DC pulse
+
4
Control output R2 type OA: active 24V DC pulse
16 15 2
2
3
3
e.g. relay or solenoid
Main supply
8 - 24V AC
0
L1 Power supply type PM: 115 - 230V AC
N
Earth
8 - 24V DC
-
Power supply type PD: 8 - 24V AC / DC
+
1
13
Control outputs type OR: mechanic relay
Common ground
Earth
*Supply voltage: 3.2 / 8.2 / 12 / 24V DC to sensor
F132
10
e.g. relay or solenoid
e.g. relay
Main supply
Common ground
Power supply PX: 8 - 30V DC (not used in this example)
6
7
Common ground
e.g. relay
5
Main supply
Power supply PX: 8 - 30V DC (not used in this example)
6
+
Common ground
11
Common ground
Flowmeter input type: P pulse
5
8
Common ground
Signal
4
Main supply
Supply *
9
Circuit depends on type of signal
Flowmeter input type: P pulse
Logic input: START
12
Common ground
Logic input: PAUSE / STOP
8
Logic input: START
11 10
Signal
Common ground
T:
+ 3.2V 1M low-pass filter
26
27 26
Common ground
Supply *
Common ground
T:
Logic input: PAUSE / STOP
9
Circuit depends on type of signal
Common ground
+ 3.2V 1M low-pass filter
7
+ 3.2V 1M low-pass filter
ASCII data printer communication type CI: RS485 - 4 wire
1
Common ground
115 - 230V AC POWER SUPPLY
0
+ 3.2V 1M low-pass filter
Common ground
16
Common ground
15
DTR 12V
A
13
RXD
B
12
TXD
Y
28
ASCII data printer communication type CB: RS232
Z
31
TERMINAL CONNECTORS F100-series
30
TERMINAL CONNECTORS F100-series
*Supply voltage: 3.2 / 8.2 / 12 / 24V DC to sensor
5
Hazardous area applications
Certificate of conformity KEMA 03ATEX1074 X • IECEx DEK 11.0042X
The F132-XI has been certified according ATEX and IECEx by DEKRA for use in Intrinsically Safe applications with an ambient temperature of -40°C to +70°C (-40°F to +158°F). • The ATEX markings for gas and dust applications are: II 1 G Ex ia IIB/IIC T4 Ga II 1 D Ex ia IIIC T100 ¡C Da IP6X. • The IECEx markings for gas and dust applications are: Ex ia IIC/IIB T4 Ga and Ex ia IIIC T100 ¡C Da IP6X. Besides the I.S. power supplies for the control outputs, it is allowed to connect up to two I.S. power supplies in IIB/IIIC applications or one in IIC applications. Consult the certificate for the maximum input and output values of the circuits. Full functionality of the F132 remains available, including two stage control and Modbus communication (type CT). Power supply type PD-XI offers a 8.2V sensor supply e.g. for one Namur sensor. A flame proof enclosure with rating ATEX II 2 GD EEx d IIB T5 is available as well. Please contact your supplier for further details.
6
F132
Configuration example IIB / IIIC and IIC - F132-P-(CT)-OT-PX-XI - Battery powered unit
HAZARDOUS AREA
TERMINAL CONNECTORS F100-series
SAFE AREA
RXD
Uo=max 30V
28
TXD
29
ASCII data communication type CT: TTL Please note: communciation type CT is not allowed in IIC applications.
+ 27
Po=max 850mW For example: MTL5051
26
Common ground
Printer
-
DTR +12V
Io=max 250mA
ISOLATOR: I.S. Certified Isolator TTL to RS232 / RS422 / TTL
Ci is negligibly small
Logic input: START
15
Logic input: PAUSE / STOP
11
Supply *
Flowmeter input type: P pulse
Main supply
8
Common ground
7
Common ground
10
Signal
Ci is negligibly small
9
Circuit depends on type of signal
Common ground
Ci is negligibly small
14
+ 3.2V 1M low-pass filter
13
Common ground
12
+ 3.2V 1M low-pass filter
16
* Note: Communication only allowed when configured as IIB / IIIC.
Power supply type PX: 8 - 30V DC (not used in this example)
Please note: type PX may be used in combination with the battery (type PC), but only in IIB applications! PX will power the unit; the battery will be disabled automatically till power is disconnected.
5 4 3
POWER SUPPLY Uo=max 30V e.g. MTL 5525 Io=max 100mA or SWITCH INTERFACE Po=max 750mW e.g. MTL 5511 e.g. relay Note: above values are safety values. Consult the technical specification for operational values.
7
-
Control output R2 type OT: passive transistor
* Note sensor supply voltage: 1.2V DC for coil sensors or 3.2V DC for other pulse sensors.
F132
Po=max 750mW
e.g. relay
Ci is negligibly small
POWER SUPPLY e.g. MTL 5525 or SWITCH INTERFACE e.g. MTL 5511
-
Common ground
Control output R1 type OT: passive transistor
Uo=max 30V Io=max 100mA
+
6
+ Common ground
e.g. relay
Ci is negligibly small
e.g. relay
Configuration example IIB / IIIC and IIC - F132-P-(CT)-OT-PX-XI - Basic power supply 8 - 30V DC
HAZARDOUS AREA
TERMINAL CONNECTORS F100-series
SAFE AREA
RXD
Uo=max 30V
28
TXD
29
ASCII data communication type CT: TTL Please note: communciation type CT is not allowed in IIC applications.
+ 27
Po=max 850mW For example: MTL5051
26
Common ground
Printer
-
DTR +12V
Io=max 250mA
ISOLATOR: I.S. Certified Isolator TTL to RS232 / RS422 / TTL
Ci is negligibly small
Logic input: START
15
Logic input: PAUSE / STOP
11
Supply *
Flowmeter input type: P pulse
Common ground
9
10
Signal
Main supply
8
Circuit depends on type of signal
Common ground
Ci is negligibly small
14
+ 3.2V 1M low-pass filter
13
Common ground
12
+ 3.2V 1M low-pass filter
16
* Note: Communication only allowed when configured as IIB / IIIC.
Ci is negligibly small
+ 7 5 4 3
POWER SUPPLY Uo=max 30V e.g. MTL 5525 Io=max 100mA or SWITCH INTERFACE Po=max 750mW e.g. MTL 5511 e.g. relay Note: above values are safety values. Consult the technical specification for operational values.
-
Control output R2 type OT: passive transistor
POWER SUPPLY e.g. MTL 5525 or SWITCH INTERFACE e.g. MTL 5511
Po=max 750mW
e.g. relay
Ci is negligibly small
Uo=max 30V Io=max 100mA
For example MTL 5525
-
Common ground
Control output R1 type OT: passive transistor
Po=max 750mW
POWER SUPPLY
+
6
+ Common ground
e.g. relay
Ci is negligibly small
Uo=max 30V Io=max 100mA
-
Common ground
Power supply type PX: 8 - 30V DC
e.g. relay
* Note sensor supply voltage: 1.2V DC for coil sensors or 3.2V DC for other pulse sensors.
8
F132
Configuration example IIB / IIIC and IIC - F132-P-(CT)-OT-PD-XI - Power supply 16 - 30V DC
HAZARDOUS AREA
TERMINAL CONNECTORS F100 - series
SAFE AREA
RXD
Uo=max 30V
28
TXD
29
ASCII data communication type CT: TTL Please note: communciation type CT is not allowed in IIC applications.
+ 27 26
Common ground
Po=max 850mW
Printer
For example: MTL5051
-
DTR +12V
Io=max 250mA
ISOLATOR: I.S. Certified Isolator TTL to RS232 / RS422 / TTL
Ci is negligibly small
Logic input: START
15
Logic input: PAUSE / STOP
11
Supply *
Common ground
10
Signal
Ci is negligibly small
Flowmeter input type: P pulse
9
Circuit depends on type of signal
Common ground
Ci is negligibly small
14
+ 3.2V 1M low-pass filter
13
Common ground
12
+ 3.2V 1M low-pass filter
16
* Note: Communication only allowed when configured as IIB / IIIC.
Control output R1 type OT: passive transistor
4
e.g. relay
POWER SUPPLY Uo=max 30V e.g. MTL 5525 or Io=max 100mA SWITCH INTERFACE Po=max 750mW e.g. MTL 5511
Control output R2 type OT: passive transistor
e.g. relay
2
3
Ci is negligibly small
-
6 5
e.g. relay
Common ground
POWER SUPPLY e.g. MTL 5525 or SWITCH INTERFACE Po=max 750mW e.g. MTL 5511 Uo=max 30V
Io=max 100mA
+
Common ground
+
e.g. relay Ci is negligibly small
Power supply type PD: 16 - 30V DC (please note: PD and battery supply (type PC) is NOT allowed in IIC applications).
0
Uo=max 30V Io=max 100mA
-
Common ground
1
+ Main supply
Po=max 750mW
POWER SUPPLY For example MTL 5525
Note: above values are safety values. Consult the technical specification for operational values. * Note power supply type PD: the supply voltage to pulse sensors is maximum 8.7V (Uo=max 8.7V Io=max 25mA Po=max 150mW).
F132
9
Technical specification
Casing General
General
Window Sealing Control keys
Display Type Dimensions Digits Refresh rate Option ZB Note ZB
High intensity reflective numeric and alphanumeric LCD, UV-resistant. 90 x 40mm (3.5” x 1.6”). Seven 17mm (0.67") and eleven 8mm (0.31") digits. Various symbols and measuring units. User definable: 8 times/sec. - 1 time/30 secs. Transflective LCD with green LED backlight. Good readings in full sunlight and darkness. Only available for safe area applications.
Aluminum wall / field mount enclosures General Dimensions Weight
Type HA Type HM Type HN Type HO Type HP Type HT Type HU Type HV Type HZ
Operating temperature Standard unit -40°C to +80°C (-40°F to +176°F). Intrinsically Safe -40°C to +70°C (-40°F to +158°F).
Power requirements Type PB
Long life Lithium battery - life-time depends upon settings and configuration - up to 5 years. Type PC Intrinsically Safe long life lithium battery - life-time depends upon settings and configuration - up to 5 years. Type PD 8 - 24V AC / DC ± 10%. Power consumption max. 10 Watt. Intrinsically Safe: 16 - 30V DC; power consumption max. 0.75 Watt. Type PF 24V AC / DC ± 10%. Power consumption max. 15 Watt. Type PM 115 - 230V AC ± 10%. Power consumption max. 15 Watt. Type PX 8 - 30V DC. Power consumption max. 0.5 Watt. Type ZB Internally powered, only available with type PD / PF / PM. Power consumption max. 1 Watt. Note PB/PF/PM Not availble Intrinsically Safe. Note PF/PM The total consumption of the sensors and outputs may not exceed 400mA @ 24V. Note For Intrinsically Safe applications, consult the safety values in the certificate.
Note
Type PD Type PD-XI Type PF / PM
General Dimensions Weight
Type HD Type HE Type HF Type HG Type HH Type HJ Type HK
Dimensions Panel cut-out
Type HB
3.2V DC for pulse signals and 1.2V DC for coil pick-up. This is not a real sensor supply. Only suitable for sensors with a very low power consumption like coils (sine wave) and reed-switches. 1.2 / 3.2 / 8.2 / 12 / 24V DC - max. 50mA @ 24V DC. 1.2 / 3.2 / 8.2V DC - max. 7mA @ 8.2V DC and mains power supply voltage (as connected to terminal 1). 1.2 / 3.2 / 8.2 / 12 / 24V DC - max. 400mA @ 24V DC.
Weight
Type HC Weight
Removable plug-in terminal strip. Wire max. 1.5mm2 and 2.5mm2.
Dimensions Weight
Type HS
Data protection Pass-code
130 x 120 x 60mm (5.12" x 4.72" x 2.36") - W x H x D. 115 x 98mm (4.53" x 3.86") L x H. Die-cast aluminum panel mount enclosure IP65 / NEMA 4X. 600 gr. GRP panel mount enclosure IP65 / NEMA 4X, UV-resistant and flame retardant. 450 gr.
ABS wall / field mount enclosures General
Type
GRP wall/field mount enclosure IP67 / NEMA 4X, UV-resistant and flame retardant. 130 x 120 x 75mm (5.12" x 4.72" x 2.95") - W x H x D. 600 gr. Cable entry: no holes. Cable entry: 2 x Ø 16mm and 1 x Ø 20mm. Cable entry: 1 x Ø 22mm (7/8"). Cable entry: 2 x Ø 20mm. Cable entry: 6 x Ø 12mm. Cable entry: 3 x Ø 22mm (7/8"). Flat bottom, cable entry: no holes.
Panel mount enclosures
Terminal connections Type
Die-cast aluminum wall/field mount enclosure IP67 / NEMA 4X with 2-component UV-resistant coating. 130 x 120 x 75mm (5.12" x 4.72" x 2.95") - W x H x D. 1100 gr. Cable entry: 2 x PG9 and 1 x M20. Cable entry: 2 x M16 and 1 x M20. Cable entry: 1 x M20. Cable entry: 2 x M20. Cable entry: 6 x M12. Cable entry: 1 x 1/2" NPT. Cable entry: 3 x 1/2" NPT. Cable entry: 4 x M20. Cable entry: no holes.
GRP wall / field mount enclosures
Sensor excitation Type PB/PC/PX
Polycarbonate window. Silicone. Three industrial micro-switch keys. UV-resistant silicone keypad.
Silicone free ABS wall/field mount enclosure IP65 with EPDM and PE sealings. UV-resisitant polyester keypad (old HD enclosure). 130 x 114 x 71mm (5.1" x 4.5" x 2.8") - W x H x D. 450 gr. Cable entry: no holes.
EEPROM backup of all settings. Backup of running totals every minute. Data retention at least 10 years. Configuration settings can be pass-code protected.
10
F132
Hazardous area Intrinsically Safe (Type XI) ATEX certification IECEx certification Ambient Ta
Operational Operator functions
II 1 G Ex ia IIB/IIC T4 Ga. II 1 D Ex ia IIIC T100 °C Da IP6X. Ex ia IIC/IIB T4 Ga. Ex ia IIIC T100 °C Da IP6X. -40°C to +70°C (-40°F to +158°F).
Displayed functions
Explosion proof (Type XF) ATEX certification Dimensions Weight
Preset and total
II 2 GD EEx d IIB T5. 300 x 250 x 200mm (11.8" x 9.9" x 7.9") L x H x D. Appr. 15kg.
Digits Units Decimals Note
Environment Electromagnetic Compliant ref: EN 61326 (1997), EN 61010-1 (1993). compatibility
Digits 11 digits. Units / decimals According to selection for total. Note Can not be reset to zero.
Signal inputs
Frequency
K-Factor Low-pass filter Option ZF
Coil / sine wave (minimum 20mVpp or 80mVpp sensitivity selectable), NPN/PNP, open collector, reedswitch, Namur, active pulse signals 8 - 12 and 24V DC. Minimum 0Hz - maximum 7kHz for total and flow rate. Maximum frequency depends on signal type and internal low-pass filter. E.g. reed switch with low-pass filter: max. frequency 120Hz. 0.000010 - 9,999,999 with variable decimal position. Available for all pulse signals. coil sensitivity 10mVpp.
Accessories Mounting accessories ACF02 ACF05 ACF06 ACF07 ACF08 ACF09 ACF10
Logic inputs Function Type Duration
Two terminal inputs to start, pause and stop the batch process. Internally pulled-up switch contact - NPN. Minimum pulse duration 100msec.
Type OR
Type OT
Stainless steel wall mounting kit. Stainless steel pipe mounting kit (worm gear clamps not included). Two stainless steel worm gear clamps Ø 44 - 56mm. Two stainless steel worm gear clamps Ø 58 - 75mm. Two stainless steel worm gear clamps Ø 77 - 95mm. Two stainless steel worm gear clamps Ø 106 - 138mm. Customized Grevopal tagplates for ACF02 and ACF05, including stainless steel screws. Dimension: 95mm x 12.5mm (3.75” x 0.50”).
Cable gland accessories ACF20 ACF25 ACF26 ACF27 ACF28 ACF29 ACF32 ACF33 ACF34 ACF35 ACF39 ACF40
Signal outputs Control / pulse output Function Type OA
7 digits. L, m3, GAL, USGAL, kg, lb, bbl, no unit. 0 - 1 - 2 or 3. Total can be reset to zero.
Accumulated total
Flowmeter Type P
• Preset value - can be entered by the operator. • Batched quantity or remaining quantity. • Total and accumulated total. • Nr. of batches. • Reprint the last receipt. • No-flow alarm.
User defined: batch process one or two stage control. Two active 24V DC transistor outputs (PNP); max. 50mA per output (requires PD, PF or PM). Two electro-mechanical relay outputs (N.O.) - isolated; max. switch power 230V AC - 0.5A per relay (requires PF or PM). Two passive transistor outputs (NPN) - not isolated. Max. 50V DC - 300mA per output.
For HA enclosure, includes O-rings. For HE enclosure, includes locknuts and O-rings. For HF enclosure, includes locknuts and O-rings. For HG enclosure, includes locknuts and O-rings. For HH enclosure, includes locknuts and O-rings. For HJ enclosure, includes locknuts and O-rings. For HM enclosure, includes O-rings. For HN enclosure, includes O-rings. For HO enclosure, includes O-rings. For HP enclosure, includes O-rings. For HT enclosure, includes O-rings. For HU enclosure, includes O-rings.
Blind plug accessories ACF50 ACF55 ACF56 ACF57 ACF58 ACF59 ACF62 ACF63 ACF64 ACF65 ACF69 ACF70
Printer communication option Function Protocol Speed Type CB H Type C Type CI Type CT
F132
Send a “print receipt” command after every batch. ASCII data. 1200 - 2400 - 4800 - 9600 baud. RS232 RS485 2-wire RS485 4-wire TTL Intrinsically Safe.
11
For HA enclosure, includes O-rings. For HE enclosure, includes locknuts and O-rings. For HF enclosure, includes locknuts and O-rings. For HG enclosure, includes locknuts and O-rings. For HH enclosure, includes locknuts and O-rings. For HJ enclosure, includes locknuts and O-rings. For HM enclosure, includes O-rings. For HN enclosure, includes O-rings. For HO enclosure, includes O-rings. For HP enclosure, includes O-rings. For HT enclosure, includes O-rings. For HU enclosure, includes O-rings.
Ordering information Standard configuration: F132-P-AX-CX-EX-HC-IX-OT-PX-TX-XX-ZX. Ordering information: F132 -_ -AX -C _ Flowmeter input signal P
-EX
-H _
-IX
-O _
-P _
-TX
-X _
Pulse input: coil, npn, pnp, namur, reed-switch.
Analog output signal AX
No analog output.
Printer communication
CB H C CI CT CX
Communication RS232 - ASCII data. Communication RS485 - 2-wire - ASCII data. Communication RS485 - 4-wire - ASCII data. Intrinsically Safe TTL - ASCII data. No printer communication.
Flow equations EX
No flow equations.
Panel mount enclosures - IP65 / NEMA4X HB HC
Aluminum enclosure. GRP enclosure.
GRP field / wall mount enclosures - IP67 / NEMA4X HD HE HF HG HH HJ HK
Cable entry: no holes. Cable entry: 2 x Ø 16mm & 1 x Ø 20mm. Cable entry: 1 x Ø 22mm (7/8”). Cable entry: 2 x Ø 20mm. Cable entry: 6 x Ø 12mm. Cable entry: 3 x Ø 22mm (7/8”). Flat bottom, cable entry: no holes.
Aluminum field / wall mount enclosures - IP67 / NEMA4X HA HM HN HO HP HT HU HV HZ
Cable entry: 2 x PG9 + 1 x M20. Cable entry: 2 x M16 + 1 x M20. Cable entry: 1 x M20. Cable entry: 2 x M20. Cable entry: 6 x M12. Cable entry: 1 x 1/2”NPT. Cable entry: 3 x 1/2”NPT. Cable entry: 4 x M20. Cable entry: no holes.
ABS field / wall mount enclosures - IP65 HS
Silicone free ABS field enclosure – Cable entry: no holes (old HD enclosure).
Additional inputs IX
No additional input.
Outputs OA OR OT
Two active transistor outputs - requires PD, PF or PM. Two mechanical relay outputs - requires PF or PM. Two passive transistor outputs - standard configuration.
Power supply PB PC PD PF PM PX
Lithium battery powered. Lithium battery powered - Intrinsically Safe. 8 - 24V AC/DC + sensor supply - with XI: 16 - 30V DC. 24V AC/DC + sensor supply. 115 - 230V AC + sensor supply. Basic power supply 8 - 30V DC (no real sensor supply).
Temperature input signal TX
No temperature input signal.
Hazardous area XI XF XX
Intrinsically Safe, according ATEX and IECEx. EExd enclosure - 3 keys. Safe area only.
Other options ZB ZF ZX
Backlight - requires PD, PF or PM. Coil input 10mVpp. No options.
The bold marked text contains the standard configuration. Available Intrinsically Safe.
icenta Controls Ltd, North Station Yard, Warminster Road, Wilton, Salisbury, SP2 0AT, UK Tel: +44 (0)1722 741890 Lo-Call: 0845 895 1020 Fax: +44 (0)1722 742031 Email:
[email protected] www.icenta.co.uk
-Z _