Fieldbus Segment Protector
*-JBSC-* Fieldbus junction box with integrated short-circuit current limitation Type code see overleaf
Connection
Shielding variations Main cable Trunk IN Trunk OUT
• Fieldbus distributor with individually short-circuit current limited outputs • 4, 6 or 8 outputs, certified in accordance with EEx nL IIC, for connection of spurs for one field device each • For PROFIBUS PA and FOUNDATION Fieldbus H1 • Inbuild surge protection for trunk and spurs • Fault signal via LED • Switchable integrated fieldbus terminator • Different versions of shielding are possible • Installation permissible in zone 2 • Variants for cabinet installation on DIN mounting rail • Different housing and cable connection variants for installation in the field • Cabinet variants with removable screw terminals
PA
Ti+ Ti- Tis To+ To- Tos
T
S
PA PA
Fieldbus terminator S1
I
1+
I
1- 1s 2+
Spur 1
I
2- 2s 3+
Spur 2
I
3- 3s 4+
Spur 3
I
I
4- 4s 5+ 5- 5s 6+
Spur 4
Spur 5
I
I
6- 6s 7+ - 7- 7s 8+ 8- 8s
Spur 6
Spur 7
Spur 8
Outputs S1: Fieldbus terminator, switchable
Function
Release date 2006-03-16 10:34 Date of issue 2006-03-16 T17250_ENG.xml
The *-JBSC-* Fieldbus Segment Protectors are used in signal transfer topologies based on PROFIBUS PA or FOUNDATION Fieldbus H1 fieldbus according to IEC 61158-2. They allow the distribution of the fieldbus trunk to a number of branch lines (spurs) for the connection of fieldbus devices.
Composition
Each spur is individually monitored for short circuits. Thus a fault at one spur does not have any negative feedback on the remaining segment. Each spur is designed for the connection of one field device. The trunk can be looped through. The versions R-JBSC-* are designed for cabinet installation on DIN mounting rails. For installation in the field several housing types with different cable glands as well as plug connections are available. A switchable fieldbus terminator is integrated. Several shielding variants are possible.
Subject to reasonable modifications due to technical advances.
Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
1
*-JBSC-*
Technical data
Fieldbus interface Main cable (Trunk) Connection
see table 1
Rated voltage
9 ... 31 V DC
Rated current
≤6A
Screening option
looped through direct to earth potential, trunk and outputs
Outputs Connection
see table 1
Rated voltage
≤ 31 V
Rated current
≤ 40 mA
Short-circuit current
≤ 45 mA
Screening option
looped through direct to earth potential, trunk and outputs
Self current consumption
max. 9 mA
Voltage drop main cable/outputs
≤ 1.3 V
Terminator
switchable 100 Ω integrated
Surge protection
trunk, spurs overvoltage protected if voltage exceeds typ. 39 V, max. 41 V
Indicators/operating means LED voltage Fieldbus
green: Fieldbus voltage > 10V
LED status Fieldbus
yellow: bus activity
LED state outputs
red flashing: short-circuit
Directive conformity Electromagnetic compatibility Directive 89/336/EC
standards EN 61326
Standard conformity Electromagnetic compatibility
NE 21
Protection degree
IEC 60529
Fieldbus standard
IEC 61158-2
Climatic conditions
IEC 60721
Ambient conditions Ambient temperature
see table 2
Storage temperature
-40 ... 85 °C (233 ... 358 K)
Shock resistance
15 g , 11 ms
Vibration resistance
5 g , 10 ... 150 Hz
Mechanical specifications Connection type
see table 2
Core cross-section
up to 2.5 mm2
Cable diameter
see table 3
Cable gland
see table 2
Housing
see figures 1 ... 3
Housing material R... DIN rail housing
PA 6.6
F2... aluminium housing
ALSI12 (Cu) DIN1725 (Si 1,2%), anodised
F6... stainless steel housing
1.4404 (S316L)
Protection degree
Release date 2006-03-16 10:34 Date of issue 2006-03-16 T17250_ENG.xml
R... DIN rail housing
IP20
F2... aluminium housing
IP67
F6... stainless steel housing
IP66
Mass R... DIN rail housing
380 g
F2... aluminium housing
1800 g
F6... stainless steel housing
2450 g
Mounting
panel or DIN rail mounting
Data for application in conjunction with hazardous areas Main cable (Trunk) ≤ 2.5 A
Rated current Outputs Voltage
Uo
32 V
Current
Io
45 mA
Inductance
Lo
0.25 mH
Capacitance
Co
100 nF
Statement of conformity Group, category, type of protection, temperature classification
TÜV 04 ATEX 2465 X ¬ II 3 G EEx nA [L] IIC T4
Directive conformity Subject to reasonable modifications due to technical advances.
Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
2
*-JBSC-*
Technical data EN 50021
Release date 2006-03-16 10:34 Date of issue 2006-03-16 T17250_ENG.xml
Directive 94/9 EC
Subject to reasonable modifications due to technical advances.
Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
3
*-JBSC-*
Technical data
Type code/order designation Type of housing F2
Field housing with 4, 6 or 8 outputs, aluminium
F6
Field housing with 4, 6 or 8 outputs, stainless steel
R
without field housing, for mounting in cabinet on DIN rail Type of device JBSC
Segment Protector with short-circuit power limitation Explosion protection method leave blank for general purpose applications in non-hazardous areas and Zone 2/Class I, Div. 2 Number of outputs 4 6 8 Type of cable connection Fieldbus-independent: variants with field housing and cable glands or without field housing FF
Field housing with plug connection for FOUNDATION Fieldbus
PA
Field housing with plug connection for PROFIBUS PA Connection of trunk cable similar to output cable resp. variant without field housing CG
Cable gland, plastic, M20
CGB
Cable gland, nickel plated brass, M20
CGS
Cable gland, stainless steel, M20
CGAB 7/8S
Cable gland for armoured cables, nickel plated brass, M20 Plug connection 7/8", stainless steel
M12B
Plug connection M12 x 1, nickel plated brass
M12S
Plug connection M12 x 1, stainless steel Connection of output cable (spur) Variant without field housing COM CG
Cable gland, nickel plated brass, M16
CGS
Cable gland, stainless steel, M16
CG2 CGS2 7/8S
-
JBSC
-
-
B
-
. C
D
.
. E
.
Cable gland, plastic, M16
CGB CGAB
A
Variant without field housing, plug-in terminals
Cable gland for armoured cables, nickel plated brass, M20 Cable gland, plastic, M20 Cable gland, stainless steel, M20 Plug connection, stainless steel, 7/8"
M12B
Plug connection, nickel plated brass, M12 x 1
M12S
Plug connection, stainless steel, M12 x 1
. F
.
G
Identification for assignment of the type code to the following tables
Release date 2006-03-16 10:34 Date of issue 2006-03-16 T17250_ENG.xml
Example: Segment Protector for cabinet installation on standard DIN rail, 8 outputs for FOUNDATION Fieldbus H1 and PROFIBUS PA, plug-in screw terminals: R-JBSC-8.COM Example: Segment Protector in field housing aluminium, trunk cable glands stainless steel, 6 outputs plug connection 7/8" stainless steel, pin assignment for FOUNDATION Fieldbus H1: F2-JBSC-6.FF.CGS.7/8S Note: Not all variants are available. For available variants please refer to the electronic configuration tool or contact your Pepperl+Fuchs representative.
Subject to reasonable modifications due to technical advances.
Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
4
*-JBSC-*
Technical data
Dimensions Connections Trunk
LED Connections Spurs
Fieldbus terminator, switchable DIN mounting rail
Shield brigdes 217
SPUR 2
SPUR 3
SPUR 4
SPUR 5
SPUR 6
SPUR 7
SPUR 8
TRUNK IN TRUNK OUT
100
SPUR 1
64
Cable fixing with cable tie
Mounting on DIN rail
Figure 1: R-JBSC-* for cabinet installation on DIN rail, terminal connections see table 1 258
9,5
84
228
240
for fixing with screws M6
114
x
(57)
Function unit similar R-JBSC-* see above
Release date 2006-03-16 10:34 Date of issue 2006-03-16 T17250_ENG.xml
Earthing point
SW
Spurs
Trunk OUT
Trunk IN
Figure 2: F2-JBSC-* with aluminium housing, connection variants and dimensions see table 2 ... 4
Subject to reasonable modifications due to technical advances.
Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
5
*-JBSC-*
Technical data
Function unit similar R-JBSC-* see above 320 300 280
Y
170
For mounting with screws M6
Earthing point
SW
Spurs
Trunk IN
Trunk OUT
Height of F6 housing: 86 mm
Figure 3: F6-JBSC-* with stainless steel housing, connection variants and dimensions see tables 2 ... 4
Electrical connection
Release date 2006-03-16 10:34 Date of issue 2006-03-16 T17250_ENG.xml
Table 1: Connection of terminals Terminals
Function
1+, 2+, 3+, 4+, 5+, 6+, 7+, 8+
Output (spur) +
1-, 2-, 3-, 4-, 5-, 6-, 7-, 8-
Output (spur) -
1s, 2s, 3s, 4s, 5s, 6s, 7s, 8s
Output (spur) shield
Ti +
Trunk IN +
Ti -
Trunk IN -
Tis
Trunk IN shield
To+
Trunk OUT +
To-
Trunk OUT -
Tos
Trunk OUT shield
T
Trunk, shield bridge
S
Outputs, shield bridge
PA
Potential equalization
The terminals Tis and Tos are connected internally with terminal T. The terminals 1s ... 8s are connected internally with terminal S. The terminals PA are connected with the external earthing point (versions with field housing only). Different connections of the terminals T, S and PA allow to choose different shielding concepts. Variants R-JBSC-*.COM have plug-in terminals.
Subject to reasonable modifications due to technical advances.
Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
6
*-JBSC-*
Technical data Table 2: Variations of cable connections, housing types and temperature ranges Type of connection, identification F, G
Type of cable connection
Number of outputs (spurs) identification D 4
6
8
CG
Terminals, cable glands plastic
X
X
X
CGB
Terminals, cable glands nickel plated brass
X
X
X
CGS
Terminals, cable glands stainless steel
X
X
–
CGAB
Terminals, cable glands nickel plated brass for armoured cable
X
–
CG2
Terminals, cable glands plastic
X
–
CGS2
Terminals, cable glands stainless steel
X
M12B
Plug connection M12 x 1, nickel plated brass
M12S
Plug connection M12 x 1, stainless steel
7/8S
Plug connection 7/8", stainless steel
without field housing (R-JBSC-*)
Terminals
F2 housing, outside dimension "X" (mm)
F6 housing, outside dimension "Y" (mm)
SW (mm)
Temperature range (°C)
140
200
20
-30 ... 70
140
n.a.
20
-40 ... 70
140
200
22
-40 ... 70
–
160
220
24
-40 ... 70
–
140
200
24
-30 ... 70
–
–
140
200
24
-40 ... 70
X
X
X
135
195
n.a.
-25 ... 70
X
X
X
135
195
n.a.
-25 ... 70
X
X
X
135
195
n.a.
-40 ... 70
X
X
X
n.a.
n.a.
n.a.
-50 ... 70
Table 3: Cable diameter depending on cable gland Type of connection identification F, G
Cable diameter (mm)
CG
5 ... 10
CGB
5 ... 10
CGS
5 ... 10
CGAB
8.5 ... 16 outside 6 ... 12 inside 0 ... 1.25 armour
CG2
7 ... 12
CGS2
7 ... 12
Table 4: Pin assignment of plug connections
Outputs Trunk OUT
Outputs Trunk OUT
Trunk IN
Trunk IN
3
4
4
3
3
1
1
3
2
1
1
2
4
2
2
4
Plug connection 7/8"
Plug connection M12 x 1 Pin
PROFIBUS PA
1
PA+
FOUNDATION Fieldbus Data-
2
n.c. (GND)
Data+
3
PA-
Shield
4
Shield
n.c. (GND)
Release date 2006-03-16 10:34 Date of issue 2006-03-16 T17250_ENG.xml
Note for connector variants: Outputs (spur, trunk Out) are always sockets (female). Trunk IN is always plug (male).
Installation note see manual
Accessories Socket M12 x 1:
blind plug
VAZ-V1-B
Socket M20:
bind plug
CG EX PLUG MT 20X
Socket 7/8":
blind plug
V9-R-F-COV
Subject to reasonable modifications due to technical advances.
Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
7