Preview only show first 10 pages with watermark. For full document please download

Fa12 160

   EMBED


Share

Transcript

FA 12-160 12V160Ah Front Access SLA Battery Range Summary By combining the newly developed paste formula with up-to-date AGM structures, BSB created the innovation FA range of batteries. The range features 12 years design life and front access connections for fast, easy installation and maintenance. This series is highly suited to telecom applications, UPS systems and other back up applications. Application · Telecom · Control Equipment · UPS · Communication Equipment · Medical Equipment · Emergency Power System General Features · Easy maintenance and installation · No need for extra (wrench space) above battery · Sealed and maintenance free operation · Non-Spillable construction design · ABS containers and covers(UL94 V0,optional) · Safety valve installation for explosion proof · Maximized energy density for installation in relay rack trays · High quality and high reliability · Exceptional deep discharge recovery performance · Flexible design for multiple installation positions 3mm (0.12inch) 16mm (0.63inch) M8mm (0.31inch) Construction Lead dioxide Lead ABS ABS Epoxy Resin Safety valve Terminal Separator Electrolyte ...... ...... ...... ...... EPDM Copper AGM Sulfuric acid Terminal Dimensions 315mm(12.4inch) Positive ...... Negative ...... Container ...... ...... Cover Sealant ...... 546mm(21.5inch) 125mm(4.92inch) Battery Model FA12-160 Designed Floating Life Capacity(20oC) Dimensions 12 Years 20HR(8.5A,1.80V) 10HR(16.0A,1.80V) 5HR(28.0A,1.75V) 170Ah 160Ah 140Ah 100Ah Length Width Height Total Height 546mm(21.5inch) 125mm(4.92inch) 315mm(12.4inch) 315mm(12.4inch) Approx. Weight 51Kg (112 lbs) Internal Resistance Full charged at 20oC: 0.004 Ohm Self Discharge 3% of capacity declined per month at (20oC) Capacity Affected by Temp.(10HR) Charge Voltage(20oC) 1HR(100A,1.60V) 40oC 20oC 0oC -15oC 109% 100% 85% 65% Cycle use o 14.1-14.4V(-30mV/ C), max. Current: 40A Page 1 of 2 Float use 13.5-13.7V(-18mV/ oC) FA 12-160 12V160Ah Charge Voltage (CA) (V/Cell) (%) 120 100 0.25 Charge Capacity 2.17 100%Discharge 0.20 60 2.00 50%Discharge 0.15 40 0.10 20 1.83 0.05 0 0 Discharge Characteristic (20 C) Constant Charge at 0.25CA-2.35V (20oC) Charge Voltage 2.35 80 o Charge Characteristic Charge Current 0 2 4 6 8 10 Discharge Voltage (V/Cell) Current Charge Charge Capacity Front Access SLA Battery 2.17 2.00 1.83 0.25CA 0.1CA 0.05CA 1.67 1.60 3CA 2CA 1CA 6 12 30 1.33 0 12 2 2.25 110 105 2.17 100 95 90 Capacity (%) Battery Voltage (V/Cell) 3 10 Hour 20 Self Discharge Characteristics Relationship of OCV and state of charge 2.00 60 Min Time(hour) 2.08 0.6CA 85 80 75 70 65 60 55 50 1.92 1.83 40oC 45 0 10 20 30 40 50 60 70 80 90 100 40 0 1 2 20oC 30oC 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Storage time:months Remained Capacity(%) Constant current discharge ratings-amperes at 20oC F.V/T im e 1 .60 V 1 .67 V 1 .70 V 1 .75 V 1 .80 V 1 .85 V 5 m in 56 0 50 4 47 8 42 6 38 4 29 1 10 m in 384 350 338 312 290 238 1 5 m in 2 80 2 72 2 62 2 48 2 37 2 05 3 0m in 16 8 16 3 16 0 15 7 15 2 14 0 1h 100 9 9.5 9 9.0 9 8.5 9 8.0 9 7.2 3h 43 .7 43 .5 43 .4 43 .2 43 .0 42 .9 5h 2 8 .6 2 8 .4 2 8 .2 2 8 .0 2 7 .9 2 7 .7 10h 1 7.0 1 6.7 1 6.6 1 6.3 1 6.0 1 5.7 2 0h 8.8 5 8.8 2 8.8 0 8.7 8 8.5 0 7.9 6 1h 208 201 196 194 191 189 3h 83 .8 83 .5 83 .0 82 .6 81 .4 81 .1 5h 5 4 .8 5 4 .6 5 4 .4 5 4 .2 5 3 .3 5 2 .5 10h 3 3.9 3 3.4 3 3.2 3 2.6 3 2.0 3 1.5 2 0h 17 .7 17 .5 17 .3 17 .1 16 .9 15 .9 Constant power discharge ratings-watts at 20oC F.V/T im e 1 .60 V 1 .67 V 1 .70 V 1 .75 V 1 .80 V 1 .85 V 5 m in 92 3 87 5 81 8 76 2 68 3 54 7 10 m in 637 629 613 573 533 442 1 5 m in 4 96 4 91 4 83 4 54 4 27 3 73 3 0m in 31 7 31 0 30 2 29 4 28 6 26 2 ISO9001 COPYRIGHT BSB POWER COMPANY LIMITED Page 2 of 2 (Updated: 1-May-2011)