Transcript
FA 12-26
12V26Ah
Front Access SLA Battery Range Summary By combining the newly developed paste formula with up-to-date AGM structures, BSB created the innovation FA range of batteries. The range features 12 years design life and front access connections for fast, easy installation and maintenance. This series is highly suited to telecom applications, UPS systems and other back up applications.
Application · Telecom · Control Equipment · UPS
· Communication Equipment · Medical Equipment · Emergency Power System
General Features · Easy maintenance and installation · No need for extra (wrench space) above battery · Sealed and maintenance free operation · Non-Spillable construction design · ABS containers and covers(UL94 V0,optional) · Safety valve installation for explosion proof · Maximized energy density for installation in relay rack trays · High quality and high reliability · Exceptional deep discharge recovery performance · Flexible design for multiple installation positions
3mm (0.12inch)
15mm (0.59inch)
M6mm (0.24inch)
Construction
148.5mm(5.85inch)
Lead dioxide Lead ABS ABS Epoxy Resin
Safety valve Terminal Separator Electrolyte
...... ...... ...... ......
EPDR Copper AGM Sulfuric acid
Terminal Dimensions
146.5mm(5.76inch)
Positive ...... Negative ...... Container ...... ...... Cover Sealant ......
250mm(9.84inch)
97mm(3.81inch)
Battery Model
FA12-26
Designed Floating Life Capacity(20oC)
12 Years 20HR(1.38A,1.80V)
10HR(2.60A,1.80V)
27.6Ah Dimensions
5HR(4.5A,1.75V)
1HR(16.3A,1.60V)
22.5Ah
16.3Ah
26Ah
Length
Width
Height
Total Height
250mm(9.84inch)
97mm(3.81inch)
146.5mm(5.76nch)
148.5mm(5.85inch)
Approx. Weight
9.3Kg (20.5 lbs)
Internal Resistance
Full charged at 20oC: 0.0103 Ohm
Self Discharge
3% of capacity declined per month at (20oC)
Capacity Affected by Temp.(10HR) Charge Voltage(20oC)
40oC 109%
20oC
0oC
-15oC
100%
85%
65%
Cycle use
Float use
14.1-14.4V(-30mV/ oC), max. Current: 6.5A
13.5-13.7V(-18mV/ oC)
Page 1 of 2
FA 12-26
12V26Ah
Charge Voltage
(CA) (V/Cell)
(%) 120 100
0.25
Constant Charge at 0.25CA-2.35V (20oC) Charge Capacity
Charge Voltage
2.35 80
2.17 100%Discharge
0.20
60
2.00
50%Discharge
0.15
40
0.10 20
1.83
0.05
0
0
Discharge Characteristic (20oC)
Charge Characteristic
Charge Current
0
2
4
6
8
10
Discharge Voltage (V/Cell)
Current
Charge
Charge Capacity
Front Access SLA Battery
2.17 2.00 1.83 0.25CA 0.1CA 0.05CA
1.67 1.60
3CA
2CA
1CA
6
12
30
1.33 0
12
2
2.25
110 105
2.17
100 95 90
Capacity (%)
Battery Voltage (V/Cell)
3
10 Hour
20
Self Discharge Characteristics
Relationship of OCV and state of charge
2.00
60
Min
Time(hour)
2.08
0.6CA
85 80 75 70 65 60 55 50
1.92
1.83
o
0
10
20
30
40
50
60
70
80
90
100
40 0
1
2
20oC
o
40 C
45
30 C 3 4
5
6
7
8
9 10 11 12 13 14 15 16 17 18 19 20
Storage time:months
Remained Capacity(%)
Constant current discharge ratings-amperes at 20oC
F.V/T im e 1.60V 1.67V 1.70V 1.75V 1.80V 1.85V
5min 91.0 81.9 77.7 69.2 62.4 47.3
10m in 62.4 56.9 54.9 50.7 47.1 38.7
15min 45.5 44.2 42.6 40.3 38.5 33.3
30min 27.3 26.5 26.0 25.5 24.7 22.7
1h 16.3 16.2 16.1 16.0 15.9 15.7
3h 7.10 7.07 7.05 7.02 6.99 6.97
5h 4.56 4.53 4.52 4.50 4.45 4.42
10h 2.76 2.72 2.69 2.65 2.60 2.56
20h 1.45 1.43 1.42 1.40 1.38 1.29
1h 30.4 29.4 28.6 28.4 27.9 27.6
3h 13.0 12.9 12.8 12.7 12.6 12.5
5h 9.05 9.02 9.00 8.92 8.77 8.65
10h 5.40 5.32 5.28 5.19 5.10 5.01
20h 2.69 2.67 2.65 2.60 2.57 2.42
Constant power discharge ratings-watts at 20oC
F.V/T im e 1.60V 1.67V 1.70V 1.75V 1.80V 1.85V
5min 150 142 133 124 111 88.9
10m in 103 102 100 93.1 86.6 71.8
15min 80.6 79.8 78.5 73.8 69.4 60.6
30min 51.5 50.4 49.1 47.8 46.5 42.6
ISO9001
COPYRIGHT BSB POWER COMPANY LIMITED Page 2 of 2
(Updated: 1-Nov-2010)