FA 12-26 12V26Ah Front Access SLA Battery Range Summary By combining the newly developed paste formula with up-to-date AGM structures, BSB created the innovation FA range of batteries. The range features 12 years design life and front access connections for fast, easy installation and maintenance. This series is highly suited to telecom applications, UPS systems and other back up applications. Application · Telecom · Control Equipment · UPS · Communication Equipment · Medical Equipment · Emergency Power System General Features · Easy maintenance and installation · No need for extra (wrench space) above battery · Sealed and maintenance free operation · Non-Spillable construction design · ABS containers and covers(UL94 V0,optional) · Safety valve installation for explosion proof · Maximized energy density for installation in relay rack trays · High quality and high reliability · Exceptional deep discharge recovery performance · Flexible design for multiple installation positions 3mm (0.12inch) 15mm (0.59inch) M6mm (0.24inch) Construction 148.5mm(5.85inch) Lead dioxide Lead ABS ABS Epoxy Resin Safety valve Terminal Separator Electrolyte ...... ...... ...... ...... EPDR Copper AGM Sulfuric acid Terminal Dimensions 146.5mm(5.76inch) Positive ...... Negative ...... Container ...... ...... Cover Sealant ...... 250mm(9.84inch) 97mm(3.81inch) Battery Model FA12-26 Designed Floating Life Capacity(20oC) 12 Years 20HR(1.38A,1.80V) 10HR(2.60A,1.80V) 27.6Ah Dimensions 5HR(4.5A,1.75V) 1HR(16.3A,1.60V) 22.5Ah 16.3Ah 26Ah Length Width Height Total Height 250mm(9.84inch) 97mm(3.81inch) 146.5mm(5.76nch) 148.5mm(5.85inch) Approx. Weight 9.3Kg (20.5 lbs) Internal Resistance Full charged at 20oC: 0.0103 Ohm Self Discharge 3% of capacity declined per month at (20oC) Capacity Affected by Temp.(10HR) Charge Voltage(20oC) 40oC 109% 20oC 0oC -15oC 100% 85% 65% Cycle use Float use 14.1-14.4V(-30mV/ oC), max. Current: 6.5A 13.5-13.7V(-18mV/ oC) Page 1 of 2 FA 12-26 12V26Ah Charge Voltage (CA) (V/Cell) (%) 120 100 0.25 Constant Charge at 0.25CA-2.35V (20oC) Charge Capacity Charge Voltage 2.35 80 2.17 100%Discharge 0.20 60 2.00 50%Discharge 0.15 40 0.10 20 1.83 0.05 0 0 Discharge Characteristic (20oC) Charge Characteristic Charge Current 0 2 4 6 8 10 Discharge Voltage (V/Cell) Current Charge Charge Capacity Front Access SLA Battery 2.17 2.00 1.83 0.25CA 0.1CA 0.05CA 1.67 1.60 3CA 2CA 1CA 6 12 30 1.33 0 12 2 2.25 110 105 2.17 100 95 90 Capacity (%) Battery Voltage (V/Cell) 3 10 Hour 20 Self Discharge Characteristics Relationship of OCV and state of charge 2.00 60 Min Time(hour) 2.08 0.6CA 85 80 75 70 65 60 55 50 1.92 1.83 o 0 10 20 30 40 50 60 70 80 90 100 40 0 1 2 20oC o 40 C 45 30 C 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Storage time:months Remained Capacity(%) Constant current discharge ratings-amperes at 20oC F.V/T im e 1.60V 1.67V 1.70V 1.75V 1.80V 1.85V 5min 91.0 81.9 77.7 69.2 62.4 47.3 10m in 62.4 56.9 54.9 50.7 47.1 38.7 15min 45.5 44.2 42.6 40.3 38.5 33.3 30min 27.3 26.5 26.0 25.5 24.7 22.7 1h 16.3 16.2 16.1 16.0 15.9 15.7 3h 7.10 7.07 7.05 7.02 6.99 6.97 5h 4.56 4.53 4.52 4.50 4.45 4.42 10h 2.76 2.72 2.69 2.65 2.60 2.56 20h 1.45 1.43 1.42 1.40 1.38 1.29 1h 30.4 29.4 28.6 28.4 27.9 27.6 3h 13.0 12.9 12.8 12.7 12.6 12.5 5h 9.05 9.02 9.00 8.92 8.77 8.65 10h 5.40 5.32 5.28 5.19 5.10 5.01 20h 2.69 2.67 2.65 2.60 2.57 2.42 Constant power discharge ratings-watts at 20oC F.V/T im e 1.60V 1.67V 1.70V 1.75V 1.80V 1.85V 5min 150 142 133 124 111 88.9 10m in 103 102 100 93.1 86.6 71.8 15min 80.6 79.8 78.5 73.8 69.4 60.6 30min 51.5 50.4 49.1 47.8 46.5 42.6 ISO9001 COPYRIGHT BSB POWER COMPANY LIMITED Page 2 of 2 (Updated: 1-Nov-2010)