Preview only show first 10 pages with watermark. For full document please download

Fa12 85

   EMBED


Share

Transcript

FA 12-85 12V85Ah Front Access SLA Battery Range Summary By combining the newly developed paste formula with up-to-date AGM structures, BSB created the innovation FA range of batteries. The range features 12 years design life and front access connections for fast, easy installation and maintenance. This series is highly suited to telecom applications, UPS systems and other back up applications. Application · Telecom · Control Equipment · UPS · Communication Equipment · Medical Equipment · Emergency Power System General Features · Easy maintenance and installation · No need for extra (wrench space) above battery · Sealed and maintenance free operation · Non-Spillable construction design · ABS containers and covers(UL94 V0,optional) · Safety valve installation for explosion proof · Maximized energy density for installation in relay rack trays · High quality and high reliability · Exceptional deep discharge recovery performance · Flexible design for multiple installation positions 3mm ( 0.12 inch) 18mm (0.71inch) M6mm (0.24inch) Construction Positive ...... Negative ...... Container ...... ...... Cover Sealant ...... Lead dioxide Lead ABS ABS Epoxy Resin Safety valve Terminal Separator Electrolyte ...... ...... ...... ...... EPDR Copper AGM Sulfuric acid Terminal Dimensions 105mm(4.13inch) 270mm(10.6inch) 390mm(15.4inch) Battery Model FA 12-85 Designed Floating Life Capacity(20oC) Dimensions 12 Years 20HR(4.5A,1.80V) 10HR(8.5A,1.80V) 5HR(14.7A,1.75V) 90AH 85AH 73.5AH Length Width Height Total Height 390mm(15.4inch) 105mm(4.13inch) 270mm(10.6inch) 270mm(10.6inch) Approx. Weight 53.3AH 31Kg (68.4 lbs) Internal Resistance Full charged at 20oC: 0.0065 Ohm Self Discharge 3% of capacity declined per month at (20oC) Capacity Affected by Temp.(10HR) Charge Voltage(20oC) 1HR(53.3A,1.60V) 40oC 20oC 0oC -15oC 109% 100% 85% 65% Cycle use 14.1-14.4V(-30mV/ oC), max. Current: 21.25A Page 1 of 2 Float use 13.5-13.7V(-18mV/ oC) FA 12-85 12V85Ah Charge Voltage (CA) (V/Cell) (%) 120 100 80 0.25 Constant Charge at 0.25CA-2.35V (20oC) Charge Capacity Charge Voltage 2.35 2.17 100%Discharge 0.20 60 2.00 50%Discharge 0.15 40 0.10 20 1.83 0.05 0 0 Discharge Characteristic (20oC) Charge Characteristic Charge Current 0 2 4 6 8 10 Discharge Voltage (V/Cell) Current Charge Charge Capacity Front Access SLA Battery 2.17 2.00 1.83 0.25CA 0.1CA 0.05CA 1.67 1.60 3CA 2CA 1CA 6 12 30 1.33 0 12 2 60 3 Min Time(hour) 10 Hour 20 Self Discharge Characteristics Relationship of OCV and state of charge 2.25 110 105 2.17 100 95 90 Capacity (%) Battery Voltage (V/Cell) 0.6CA 2.08 2.00 85 80 75 70 65 60 55 50 1.92 1.83 o 0 10 20 30 40 50 60 70 80 90 100 40 0 1 2 20oC o 40 C 45 30 C 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Storage time:months Remained Capacity(%) Constant current discharge ratings-amperes at 20oC F.V/ Time 1.60V 1.67V 1.70V 1.75V 1.80V 1.85V 5min 298 268 254 226 204 155 10min 204 186 179 166 154 127 15min 149 145 139 132 126 109 30min 89.3 86.7 85.0 83.3 80.8 74.3 1h 53.3 53.2 53.1 52.5 51.8 51.3 3h 23.3 23.2 23.1 23.0 22.9 22.8 5h 15.0 14.9 14.8 14.7 14.6 14.4 10h 9.01 8.85 8.81 8.66 8.50 8.36 20h 4.70 4.64 4.60 4.55 4.50 4.23 30min 168 165 161 156 152 139 1h 105 102 98.8 97.9 96.3 95.4 3h 44.5 44.3 44.2 43.9 43.3 43.1 5h 28.5 28.3 28.2 28.0 27.8 27.4 10h 18.0 17.8 17.6 17.3 17.0 16.7 20h 9.41 9.37 9.35 9.33 9.00 8.46 Constant power discharge ratings-watts at 20oC F.V/ Time 1.60V 1.67V 1.70V 1.75V 1.80V 1.85V 5min 490 465 434 405 363 291 10min 338 334 326 304 283 235 15min 264 261 257 241 227 198 ISO9001 COPYRIGHT BSB POWER COMPANY LIMITED Page 2 of 2 (Updated: 1-Nov-2010)