Preview only show first 10 pages with watermark. For full document please download

Fa6 200

   EMBED


Share

Transcript

FA 6-200 6V200Ah Front Access SLA Battery Range Summary By combining the newly developed paste formula with up-to-date AGM structures, BSB created the innovation FA range of batteries. The range features 12 years design life and front access connections for fast, easy installation and maintenance. This series is highly suited to telecom applications, UPS systems and other back up applications. Application · Communication Equipment · Medical Equipment · Emergency Power System · Telecom · Control Equipment · UPS General Features · Easy maintenance and installation · No need for extra (wrench space) above battery · Sealed and maintenance free operation · Non-Spillable construction design · ABS containers and covers(UL94 V0,optional) · Safety valve installation for explosion proof · Maximized energy density for installation in relay rack trays · High quality and high reliability · Exceptional deep discharge recovery performance · Flexible design for multiple installation positions 3mm ( 0.12 inch) 18 mm ( 0.71 inch) M 8 mm ( 0.31 inch) Construction Safety valve Terminal Separator Electrolyte Lead dioxide Lead ABS ABS Epoxy Resin ...... ...... ...... ...... EPDR Copper AGM Sulfuric acid Terminal Dimensions 250mm (9.84inch) Positive ...... Negative ...... Container ...... ...... Cover Sealant ...... 363mm (14.3inch) 125mm (4.92inch) Battery Model FA 6-200 Designed Floating Life Capacity(20oC) Dimensions 12 Years 20HR(10.6A,1.80V) 10HR(20A,1.80V) 212Ah 200Ah 5HR(35.4A,1.75V) 177Ah 135Ah Length Width Height Total Height 363mm(14.3inch) 125mm(4.92inch) 250mm(9.84nch) 250mm(9.84inch) Approx. Weight 34Kg (75.0 lbs) Internal Resistance Full charged at 20oC: 0.0017 Ohm Self Discharge 3% of capacity declined per month at (20oC) Capacity Affected by Temp.(10HR) Charge Voltage(20oC) 1HR(135A,1.60V) 40oC 109% 20oC 0oC 100% 85% Cycle use 7.1-7.2V(-15mV/ oC), max. Current: 50A Page 1 of 2 -15oC 65% Float use 6.8-6.9V(-9mV/ oC) FA 6-200 6V200Ah Charge Voltage Constant Charge at 0.25CA-2.35V (20oC) (CA) (V/Cell) (%) 120 100 0.25 Charge Capacity Charge Voltage 2.35 80 2.17 100%Discharge 0.20 60 2.00 50%Discharge 0.15 40 0.10 20 1.83 0.05 0 0 Discharge Characteristic (20oC) Charge Characteristic Charge Current 0 2 4 6 8 10 Discharge Voltage (V/Cell) Current Charge Charge Capacity Front Access SLA Battery 2.17 2.00 1.83 0.25CA 0.1CA 0.05CA 1.67 1.60 3CA 2CA 1CA 6 12 30 1.33 0 12 2 2.25 110 105 2.17 100 95 90 Capacity (%) Battery Voltage (V/Cell) 3 10 Hour 20 Self Discharge Characteristics Relationship of OCV and state of charge 2.00 60 Min Time(hour) 2.08 0.6CA 85 80 75 70 65 60 55 50 1.92 1.83 45 0 10 20 30 40 50 60 70 80 90 100 40 0 o 1 2 20oC o 40 C 30 C 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Storage time:months Remained Capacity(%) Constant current discharge ratings-amperes at 20oC F.V/Time 5min 10min 15min 30min 1h 3h 5h 10h 20h 1.60V 1.67V 707 636 485 442 396 384 212 206 135 133 54.9 54.7 36.2 36.0 21.3 21.0 11.2 11.1 1.70V 1.75V 604 537 426 394 371 350 202 198 132 131 54.5 54.3 35.8 35.4 20.8 20.5 11.0 10.8 1.80V 1.85V 485 368 366 301 334 289 192 177 129 128 54.1 53.9 35.0 34.5 20.0 19.8 10.6 10.1 Constant power discharge ratings-watts at 20oC F.V/Time 5min 10min 15min 30min 1h 3h 5h 10h 20h 1.60V 1.67V 1160 1099 800 790 623 617 398 390 239 231 108 106 68.1 67.9 40.7 40.1 21.3 21.1 1.70V 1.75V 1027 957 770 720 607 571 380 370 225 223 105 104 67.5 67.1 39.8 39.1 21.0 20.7 1.80V 1.85V 858 687 669 555 537 468 360 330 219 217 102 102 66.0 65.1 38.4 37.8 20.3 19.1 ISO9001 COPYRIGHT BSB POWER COMPANY LIMITED Page 2 of 2 (Updated: 1-Nov-2010)