Preview only show first 10 pages with watermark. For full document please download

Fap Wall Thermostats

   EMBED


Share

Transcript

FAP WALL THERMOSTATS WALL THERMOSTATS ROUND SERIES STANDARD SERIES 24 VOLT HEATING/COOLING THERMOSTAT AND SUB- BASES... SINGLE STAGE 24 VOLT HEATING/COOLING THERMOSTAT... SINGLE STAGES P563 FOR USE ON: P564 GENERAL AUTO FAN USE OPERATION GAS/ELECTRIC COOLING ONLY SPLIT SYSTEMS EXTRA HTG. & CLG. HH07AT184 CARRIER AND TERMINALS: SELF-CONTAINED HEATING ONLY GAS/ELECTRIC COOLING ONLY SPLIT SYSTEMS EXTRA HTG. & CLG. HH07AT183 BDP AND TERMINALS: SELF-CONTAINED HEATING ONLY GAS/ELECTRIC COOLING ONLY SPLIT SYSTEMS EXTRA HTG. & CLG. HH641601 HONEYWELL AND TERMINALS: SELF-CONTAINED HEATING ONLY THERMOSTATS • • • • • P/N FOR HEATING ONLY WITHOUT SUB-BASE QUIET SPDT MERCURY SWITCH HEATING ANTICIPATOR: .1-1.2 AMP ADJ INCLUDES CONCEALED WALL PLATE AND THREE MOUNTING SCREWS 1H/1C WITH SUB-BASES LISTED BELOW P/N HH01AD060 HH621201 HH621401 LOGO HONEYWELL BRYANT PAYNE • • SUB-BASES • • • PROVIDE MOUNTING AND MANUAL SWITCHING FOR HH01AD060 FAN SWITCH: ON-AUTO COOLING ANTICIPATOR: FIXED GENERAL AUTO USE FAN GAS/ELECTRIC COOLING HH93AZ050 SPLIT SYSTEMS & ONLY SELF CONTAINED HP, COOLING HEATING & HH93AZ051 WITH ACCESSORY COOLING ELECTRIC HEAT P/N HH93AZ053 COOLING ONLY SYSTEM COOLING ONLY HH93AZ055 COOLING ONLY SYSTEM COOLING ONLY 476 SYSTEM SWITCH COOL OFF HEAT COOL OFF HEAT COOL OFF HEAT COOL OFF ONLY LOGO QUIET SPDT MERCURY BULB SWITCH HEATING ANTICIPATOR: .18-10 AMP FAP WALL THERMOSTATS WALL THERMOSTATS HEAT ONLY THERMOSTAT SPECIAL HEAT PUMP SERIES 24 VOLT HEATING/COOLING THERMOSTAT AND SUB-BASES... SINGLE STAGE 24 VOLT HEATING/COOLING THERMOSTATS AND SUB-BASES P567 THERMOSTAT • • P566 • • THERMOSTAT P/N: • • • • • • HH01AD040 FOR HEATING ONLY WITHOUT SUB-BASE 1H/1C WITH SUB-BASE LISTED BELOW QUIET SPDT MERCURY SWITCH HEATING ANTICIPATOR:.1-1.2 AMP ADJ. INCLUDES CONCEALED WALL PLATE AND THREE MOUNTING SCREWS SUB-BASE • • • • PROVIDES MOUNTING AND MANUAL SWITCHING FOR THERMOSTAT SYSTEM SWITCH: COOL - OFF - HEAT FAN SWITCH: ON - AUTO COOLING ANTICIPATOR: FIXED FOR USE ON: P/N HH93AZ040 GENERAL USE GAS ELECTRIC SPLIT SYSTEMS AND SELF-CONTAINED AUTO FAN OPERATION COOLING ONLY P/N USE ON SUB-BASE HH07AT171 HH93AZ175 338QT HEAT PUMPS ONLY HH93AZ171 SYSTEM H/C STAGES ANTICIPATORS 1H/1C 2H/2C FIXED SUB-BASES • • WITH CARRIER LOGO SILENT, DUST-FREE MERCURY SWITCHES SEPARATE TEMPERATURE SELECTOR ARMS FOR HEATING AND COOLING SUB-BASE REQUIRED FOR MOUNTING, AND FOR SYSTEM AND FAN SWITCHING PRE-WIRED TO MAKE ELECTRICAL CONTACT WHEN MOUNTED TO SUB-BASE COVER HAS TAPPED HOLES FOR LOCKING SCREWS • • FOR USE WITH SPECIAL HEAT PUMP THERMOSTAT PROVIDE WIRING TERMINALS, MOUNTING BASE AND SYSTEM/FAN SWITCHING EMERGENCY HEAT INDICATOR LIGHT MOUNT ON WALL OR HORIZONTAL OUTLET BOX HEAT PUMPS 38 AND MISC. 38SQ AND TECH 2000 50QT ONLY CHANGEOVER TYPE AUTO MAN AUTO MAN MAN SWITCH POSITIONS SYSTEM FAN ON,OFF SUPL HT HT, COOL SUPL HT, OFF SUPL HT, ON, OFF SUPL HT, HT, OFF, COOL HEAT,COOL SUPL HT, OFF ON, AUTO ON, AUTO, ON, AUTO ON, AUTO ON, AUTO P/N HH93AZ173 HH93AZ175 HH93AZ183 HH93AZ186 HH93AZ171 477 FAP WALL THERMOSTATS WALL THERMOSTATS (HONEYWELL) MULTI-STAGE SERIES THERMOSTATS • • • • • • • • 24 VOLT HEATING/COOLING THERMOSTAT SILENT, DUST FREE MERCURY SWITCHES SEPARATE TEMPERATURE SELECTOR ARMS FOR HEATING AND COOLING SUB-BASE REQUIRED FOR MOUNTING PRE-WIRED TO MAKE ELECTRICAL CONTACT WHEN MOUNTED TO SUB-BASE COVER HAS TAPPED HOLES FOR LOCKING SCREWS ANTICIPATORS:1ST AND 2ND STAGES HEAT:.1-1.2 AMP ADJUSTABLE COOL:FIXED GENERAL USE: LOW VOLTAGE CONTROL OF MULTI-STAGE HEATING, COOLING, AND HEATING-COOLING SYSTEMS INCLUDING HEAT PUMPS SYSTEM STAGES HEAT COOL 2 1 2 2 1 1 2 1 2 2 1 1 P/N HH07AT170 HH07AT172 HH07AT174 HH621603 HH621606 HH621602 LOGO CARRIER LOGO CARRIER LOGO CARRIER LOGO HONEYWELL LOGO HONEYWELL LOGO HONEYWELL LOGO P567 MATCHING SUB-BASES • • FOR MULTI-STAGE THERMOSTATS HH07AT170, 172, 174 PROVIDE WIRING TERMINALS, MOUNTING BASE, AND SYSTEM AND FAN SWITCHING MOUNT ON WALL OR HORIZONTAL OUTLET BOX AUTOMATIC MANUAL         NONE CHANGEOVER TYPE SWITCH POSITIONS SPECIAL FEATURES* SYSTEM FAN HEAT COOL AUTO OFF EMER-HEAT NONE ON, AUTO A, F                          *A = Fan circuit energized automatically during cooling cycle only. B = Fan circuit energized automatically during cooling and heating cycles. C = Removable jumper for use on two-transformer systems. D = Extra terminal provided for heating circuit. 478         P/N HH93AZ174 A, C, D HH93AZ176 A, C, G HH93AZ177 B, C, E, G HH93AZ179 A, C, E HH93AZ184 E = Extra terminal provided for heating and cooling circuits. F = Indicator light for emergency heat. G = Indicator for lock-out or lockout. FAP WALL THERMOSTATS WALL THERMOSTATS (HONEYWELL) CLOCK THERMOSTAT WALL HUMIDISTAT P/N: HL38MG026 • • RANGE 10-60% POSITIVE ON AND OFF POSITION ELECTRICAL RATING: 50 VA @ 24 VOLT NYLON SENSING ELEMENT P562 P/N: • • • • • • • • • HH10AD144 24 VOLT HEATING/COOLING CLOCK THERMOSTAT EQUIPPED WITH A RECHARGEABLE BATTERY TO POWER THE QUARTZ CLOCK PROVIDES COMPLETE AUTOMATIC HIGH AND LOW TEMPERATURE CONTROL WITH UP TO THREE SETBACK/SET-UP PERIODS HEAT ANTICIPATOR IS ADJUSTABLE FROM.1 TO 1.2 AMP FOSSIL FUEL HEATING WALL PLATE IS INCLUDED WITH EACH THERMOSTAT. THERMOSTAT WITH CARRIER LOGO P591 Humidistat has outdoor temperatures and corresponding recommended humidity settings on face plate for reference. ADAPTER PLATE P/N: HH92AZ001 SUB-BASES • MANUAL CHANGEOVER P/N FAN SWITCH HH93AZ160 ON-AUTO HH93AZ161 ON-AUTO • SYSTEM SWITCH SINGLE HEAT-OFF-COOL TRANSFORMER SYSTEMS INDEPENDENT HEAT-OFF-COOL HEAT-COOL SYSTEMS • • THIS ADAPTER PLATE IS USED WITH T87F THERMOSTAT COVERS OLD THERMOSTAT MOUNTING MARKS 5-1/2 IN. DIAMETER P565 WALL PLATE HH99AZ161 – for L.P. Gas 479 WHITE-RODGERS WALL THERMOSTATS COMFORT-SET 11 DIGITAL THERMOSTATS WITH AUTOMATIC CHANGEOVER . • • • • • P569 • • 1F90-071 SHOWN • • • • • • • • • • P569 • • 1F97-071 SHOWN • • AUTOMATIC HEAT/COOL CHANGEOVER ALLOWS YOU TO SET THE SYSTEM SWITCH IN ONE POSITION ALL YEAR SIMULTANEOUS HEATING AND COOLING PROGRAM STORAGE ELIMINATES THE NEED TO REPROGRAM AS THE SEASONS CHANGE PRE-PROGRAMMED TIME AND TEMPERATURE SETTINGS IN ALL FOUR PROGRAMMING PERIODS FOUR SEPARATE TIME/TEMPERATURE SETTINGS IN ALL FOUR PROGRAMMING PERIODS COMPUTED EMRTM (ENERGY MANAGEMENT RECOVERY) PROGRAM ALLOWS FOR A HEAD START ON RECOVERY FROM SETBACK OR SETUP PROGRAM TEMPERATURE IS REACHED WHEN DESIRED PROGRAMMABLE FAN CONTROL PERMITS CONTINUOUS FAN DURING ANY GIVEN PROGRAM PERIOD BACKLIT DISPLAY - ENERGIZES WHENEVER THE KEYPAD OR TEMPERATURE BUTTONS ARE PRESSED AUDIO PROGRAM PROMPTING - THERMOSTAT BEEPS TO SIGNAL THAT A CHANGE HAS BEEN MADE BATTERY BACKUP CAPABILITY - SUPPLIED WITH THREE “AA” EVEREADY ALKALINE BATTERIES KEYPAD LOCKOUT ELIMINATES NEED FOR ISOLATION RELAYS COMPATIBLE WITH 3-WIRE ZONE OR 750 MILLIVOLT SYSTEMS SUITABLE FOR USE ON CENTRAL ELECTRIC HEAT SYSTEMS WHERE BLOWER IS ENERGIZED BY FAN RELAY ON HEAT AND COOL REMOTE SENSING - WHEN USED WITH F145-1049 REMOTE SENSOR (ORDER SEPARATELY) “HOLD TEMP” KEY PROVIDES MANUAL OVERRIDE OF PROGRAM °F/ °C DISPLAY INDEPENDENTLY ADJUSTABLE ANTICIPATION FOR HEATING AND COOLING COMPRESSOR SHORT CYCLE PROTECTION TEMPERATURE SET-POINTS RESET AND HOLD AT 64° F IN HEATING OR 82° F COOLING IN CASE OF POWER FAILURE AND NO BATTERY BACKUP ARM-CHAIR PROGRAMMING RED LED INDICATOR LIGHT GLOWS WHENEVER THE HEATING, COOLING OR FAN IS IN OPERATION P/N: 1F90-071 1F97-071 COMFORT-SET 11 DIGITAL THERMOSTATS • • • • • • • • P569 1F90-051 SHOWN 480 DUAL PROGRAM STORAGE ON ALL HEAT AND COOL MODELS. BACKLIT DISPLAY WHEN ANY KEY IS IN USE. THREE “AA” EVEREADY ALKALINE BATTERIES INCLUDED. SYSTEM COMPATIBILITY ON 24 VOLT SYSTEMS INCLUDING SYSTEMS WITH INTERMITTENT IGNITION CONTROLS OR VENT DAMPERS (NO NEED FOR RELAYS FOR ISOLATING CIRCUITS) EMR (ENERGY MANAGEMENT RECOVERY) FOR AN EARLY START TEMPERATURE RECOVERY IN HEATING OR COOLING PROGRAMMABLE FAN FEATURE ON HEAT/COOL MODELS WIDER 40-99° F TEMPERATURE RANGE. ALSO SUITABLE FOR CENTRAL ELECTRIC HEAT SYSTEMS. NO NEED FOR A SPECIAL THERMOSTAT MODEL P/N.: 1F90-051 1F97-051 WHITE-RODGERS WALL THERMOSTATS DIGITAL MULTI-STORAGE COMFORT-SET THERMOSTATS • • • • • • • • P569 1F91-071 SHOWN • • • • • • • • SEPARATE SET-BACK PROGRAMMING FOR FIVE DAY WEEK AND TWO DAY WEEKEND FACTORY PRE-PROGRAMMED TIME AND TEMPERATURE SETTINGS FOUR SEPARATE TIME AND TEMPERATURE SETTINGS PER 24 HOUR PERIOD AUDIO/VISUAL PROGRAM PROMPTING LCD DISPLAYS CONTINUOUS SET POINT, TIME AND ROOM TEMPERATURE AND SYSTEM MODES. “HOLD TEMP” BUTTON PROVIDES MANUAL OVERRIDE OF PROGRAM. RED LED SHOWS SYSTEM IS OPERATING (lF91-1) EASILY ACCESSIBLE TEMPERATURE BUTTONS PROVIDE TEMPORARY 2-HOUR TEMPERATURE OVERRIDE. BATTERY BACKUP CAPABILITY (9v DC ALKALINE TYPE). °F/ °C DISPLAY OPTION. INDEPENDENTLY ADJUSTABLE ANTICIPATION FOR HEATING AND COOLING. COMPRESSOR SHORT CYCLE PROTECTION. COMPRESSOR PROTECTION AS WELL FOR EXTENDED POWER OUTAGES. BACK-LIT DISPLAY PROGRAMMABLE BLOWER CONTROL COMPUTED EMR (ENERGY MANAGEMENT RECOVERY) PROGRAM OPTIONAL AUTOMATIC OR MANUAL SYSTEM CHANGEOVER (INSTALLER ADJUSTABLE). P/N: 1F91-071 DIGITAL HEAT PUMP COMFORT-SET THERMOSTATS • • • • • • • P573 1F92-071 SHOWN • • • • • • • • • SEPARATE SET-BACK PROGRAMMING FOR FIVE DAY WEEK AND TWO DAY WEEKEND FACTORY PRE-PROGRAMMED TIME AND TEMPERATURE SETTINGS FOUR SEPARATE TIME AND TEMPERATURE SETTINGS PER 24 HOUR PERIOD AUDIO/VISUAL PROGRAM PROMPTING LCD DISPLAYS CONTINUOUS SET POINT, TIME AND ROOM TEMPERATURE AND SYSTEM MODES. “HOLD TEMP” BUTTON PROVIDES MANUAL OVERRIDE OF PROGRAM. EASILY ACCESSIBLE TEMPERATURE BUTTONS PROVIDE TEMPORARY 2-HOUR TEMPERATURE OVERRIDE. BATTERY BACKUP CAPABILITY (9v DC ALKALINE TYPE). °F/°C DISPLAY OPTION. INDEPENDENTLY ADJUSTABLE ANTICIPATION FOR HEATING AND COOLING. COMPRESSOR SHORT CYCLE PROTECTION. COMPRESSOR PROTECTION AS WELL FOR EXTENDED POWER OUTAGES. BACK-LIT DISPLAY PROGRAMMABLE BLOWER CONTROL COMPUTED EMR (ENERGY MANAGEMENT RECOVERY) PROGRAM OPTIONAL AUTOMATIC OR MANUAL SYSTEM CHANGEOVER (INSTALLER ADJUSTABLE). FOUR LED INDICATOR LIGHTS EMER (RED) - SYSTEM IN EMERGENCY MODE MALF (RED) - HEAT PUMP SYSTEM MALFUNCTIONING PUMP (GREEN) - COMPRESSOR OPERATION AUX (YELLOW) - AUXILIARY HEAT ACTIVITY P/N: 1F92-071 481 WHITE-RODGERS WALL THERMOSTATS HEATING/COOLING AND COOLING ONLY ASTRO* STATS WITH SELECTOR-SWITCHES • • • • • • DUSTPROOF SEALED MERCURY CELLS OR SNAP-ACTION CONTACTS WITH DUSTCOVER BEIGE CASE WITH GOLD TONE DIAL POSITIVE CONTACT SNAP-SWITCHES ON SUBBASE BIMETAL THERMOMETER CLEAR FACEPLATE - REMOVABLE FOR EASY CLEANING HEATING AND COOLING ANTICIPATORS PROVIDE NARROW DIFFERENTIAL CONTROL OF ROOM TEMPERATURE P/N: P574 P574 1D56-310 1F56-301 1F56-444 1E56-444 P574 1D56-301 SHOWN P577 1F56-444 SHOWN 1E56-444 SHOWN ASTROSTATS WITH SNAP ACTION SWITCH • • • • SNAP ACTION CONTACTS WITH DUST COVER NON-SUSCEPTIBLE TO SLIGHT JARS AND VIBRATIONS IDEAL FOR MOBILE HOME USE HEATING AND/OR COOLING ANTICIPATORS PROVIDE A NARROW DIFFERENTIAL CONTROL OF ROOM TEMPERATURE P/N: P578 1D30-316 SHOWN P577 482 1C30-302 1D30-316 1C30-302 WHITE-RODGERS WALL THERMOSTATS AUTOMATIC COMFORT-SET CLOCK THERMOSTATS • • • • • • ALLOWS INSTALLATION OF SET BACK THERMOSTAT WITHOUT ADDITIONAL WIRING. SOLID STATE QUARTZ TIMER POWERED BY STANDARD “AA:” ALKALINE BATTERY ELIMINATES SYSTEM COMPATIBILITY PROBLEMS BATTERY MAINTAINS CORRECT TIME IN EVENT OF POWER INTERRUPTION COLOR-CODES, SNAP ON INDICATORS MAY BE POSITIONED TO RAISE OR LOWER TEMPERATURE FOR ONE OR MORE PERIODS OF TIME FOR INTERVALS AS SHORT AS TWO HOURS EQUIPPED WITH ADJUSTABLE HEAT ANTICIPATOR FOR NARROW DIFFERENTIAL CONTROL OF ROOM TEMPERATURE. ANTICIPATOR IS FIELD REPLACEABLE SNAP-ON COVER HAS CLEAR, REMOVABLE FACEPLATE FOR CLEANING. P580 P/N: 1F72-360 1F76-357 P581 1F72-360 SHOWN P582 1F76-357 SHOWN HEAT PUMP THERMOSTAT • • • • MANUAL CHANGEOVER DUAL MERCURY CELL ARRANGEMENT ON A SINGLE BI-METAL PROVIDES CONTROL WITHOUT COMPLICATED GEAR AND LEVER ARRANGEMENTS THERMOSTAT MOUNTS TO SUBBASE WITH POSITIVE CAPTIVE SCREWS SUBBASE TERMINAL SCREWS SPACED AND IDENTIFIED FOR EASY INSTALLATION P/N: 1F58-058 P583 BASIC MODEL 1F78-144 Non-Programmable • • • • SELECTABLE ENERGY MANAGEMENT RECOVERY B & O TERMINALS 60% LARGER DISPLAY 4 TIME AND 4 TEMPERATURE SETTINGS (HEAT & COOL) STANDARD SERIES 1F80-261 Programmable 5/2 Day 1F86-244 Non-Programmable P4275 483 FAP WALL THERMOSTATS STANDARD WALL THERMOSTATS (ROBERTSHAW AND WHITE-RODGERS) 24 VOLT HEATING/COOLING THERMOSTAT AND SUB-BASE STANDARD SERIES P586 SINGLE STAGE P585 THERMOSTAT THERMOSTAT • P/N: • • • • • SINGLE STAGE - FOR HEATING OR COOLING ONLY WITHOUT SUB-BASE CONVERTS TO HEATING/COOLING WITH SUB-BASE BELOW SNAP ACTING SPDT SWITCH HEAT ANTICIPATOR: .18-1.0 AMP ADJUSTABLE COOLING ANTICIPATOR: FIXED MOUNTS DIRECTLY ON WALL P/N HH01YA092 CM-260 LOGO CARRIER ROBERTSHAW • • • FOR HEATING ONLY WITHOUT SUB-BASE CONVERTS TO SINGLE STAGE HEATING AND COOLING WITH SUB-BASE BELOW SNAP ACTION BI-METAL SWITCH HEATING ANTICIPATOR: .18-1.0 AMP INCLUDES CONCEALED WALL PLATE AND TWO MOUNTING SCREWS SUB-BASES • • • • SUB-BASE • • • • • HH01PD042 MANUAL CHANGEOVER SYSTEM SWITCH: HEAT-OFF-COOL FAN SWITCH: ON-AUTO MANUAL CHANGEOVER FOR THERMOSTAT SYSTEM SWITCH: COOL-OFF-HEAT FAN SWITCH: ON-AUTO COOLING ANTICIPATOR: FIXED FOR USE ON: FOR USE ON: P/N SB-4A-12 HH93YZ094 484 GENERAL USE GAS ELECTRIC SPLIT SYSTEMS AND SELF-CONTAINED HEAT PUMP, COOLING WITH ACCESSORY ELECTRIC HEAT P/N AUTO FAN OPERATION USE ON COOLING ONLY ONE OR TWO TRANSFORMER SYSTEMS HH93PZ094 HEATING AND COOLING SINGLE TRANSFORMER SYSTEMS ONLY HH93PZ096 GENERAL USE SPLIT SYSTEMS, SELF-CONTAINED AND GAS ELECTRIC COOLING WITH ACCESSORY ELECTRIC HEAT EXTRA AUTO TERMINAL FAN PROVIDED ON OPERATION HEATING SIDE USE ON COOLING ONLY COOLING AND HEATING ONE OR TWO TRANSFORMER SYSTEMS FAP WALL THERMOSTATS WALL THERMOSTATS (HONEYWELL) LINE VOLTAGE THERMOSTAT 7-DAY PROGRAMMABLE THERMOSTAT P589 THERMOSTAT P/N: T651A2028 • • • • • • • • SNAP ACTING SPDT DUAL BI-METAL SWITCH HEATING - CONTACTS OPEN ON TEMP. RISE COOLING - CONTACTS CLOSE ON TEMP. RISE FOR HEATING, COOLING AND HEAT/COOL SYSTEMS CONTROLS FAN COILS, FANS, MOTOR STARTERS, VALVES, CONTACTORS AND CIRCULATOR MOTORS FIXED COOLING ANTICIPATOR MOUNTS ON STANDARD VERTICAL OUTLET BOX ELECTRICAL RATING (A/C AMPS) SUB-BASE • • • P584 P/N: • • • • • • • • PROVIDES MANUAL SYSTEM SWITCHING SWITCH POSITIONS: HEAT-OFF-COOL MOUNTS ON STANDARD VERTICAL OUTLET BOX HH641103 WITH CARRIER LOGO 2 STAGE HEAT AND 2 STAGE COOL TIME OF DAY DISPLAY ROOM TEMPERATURE DISPLAY PROVIDES COMPLETE AUTOMATIC HIGH AND LOW TEMPERATURE CONTROL 7 DAY PROGRAMMING 4 HEAT AND 4 COOL TEMPERATURE SELECTIONS PER DAY AUTO-CHANGEOVER INCLUDES SUBBASE AND BATTERIES WITH HONEYWELL LOGO P/N: Q473A2006 FULL LOAD LOCKED ROTOR RESISTIVE RATING: 7.2 AMP PILOT DUTY RATING: 125VA 20V 8.0 48.0 208/240V 4.0 24.0 277V 4.0 4.0 WITH CARRIER LOGO 485 MISCELLANEOUS WALL THERMOSTATS RESIDENTIAL - HEATING - HEATING/COOLING LOGO Robertshaw Bryant, Day & Night, Payne Bryant, Day & Night, Payne VENDOR & VENDOR P/N Robertshaw CM 65 W/R IF56-427 W/R ID56-340 FUNCTION TEMP RANGE (°F) HEAT ANTIC. AMPS 50 - 90 0.18 to 1.0 50 - 90 0.15 to 1.2 50 - 90 0.15 to 1.2 HeatingCooling HeatingCooling HeatingCooling NOTES P/N Add Subbase SB-6A-12 for switching (Magnetic Contacts) Includes subbase isolated “G” circuit (Mercury Switch) Includes subbase isolated “G” circuit (Magnetic Contacts) CM-65 HH642501 HH642502 SUBBASES VENDOR & VENDOR P/N Robertshaw SB-6A-12 FAN FUNCTION SWITCH Heating-Off-Cooling Auto-On NOTES P/N Use with Thermostat CM-65 SB-6A-12 HEAT PUMP LOGO Bryant, Day & Night, Payne Bryant, Day & Night, Payne Bryant, Day & Night, Payne Bryant, Day & Night, Payne 486 VENDOR & VENDOR P/N FUNCTION GE Normal-EM-Heating 3AAT83Dl4Cl Heating-Auto-Cooling GE Auto-Heating3AAT83D20Hl Cooling-Off GE Heating-Off-Cooling 3AAT83D20Bl M/H Off-EM Y594G-1245 Ht-Hi-Auto-Cool TEMP RANGE (°F) 50 - 90 50 - 90 50 - 90 HEAT ANTIC. AMPS 0.15 to 0.70 0.15 to 0.70 0.15 to 0.70 0 to 1.0 .1 to 1.2 NOTES Heat pump Automatic changeover Heat pump Automatic changeover Heat pump Manual changeover Heat pump Automatic changeover P/N HH643503 HH07QW002 HH07QW001 HH641502 ROOM AIR CONDITIONER THERMOSTATS ROOM AIR CONDITIONER THERMOSTATS • BULB TYPE, CROSS- AMBIENT CHARGE • USED WITH THERMOTUBE • 51RQ500041 • ROTATION DIAGRAMS APPLY WHEN THERMOSTAT IS VIEWED AS SHOWN IN PICTURE P597 • CAPILLARY TYPE, VAPOR CHARGE • USED WITH THERMOTUBE • 51RA500131 • ROTATION DIAGRAMS APPLY WHEN THERMOSTAT IS VIEWED AS SHOWN IN PICTURE P598 SHAFT SHOWN IN WARM POSITION W SHAFT SHOWN IN WARM POSITION C W C #1 #2 W #3 W #5 C W W #5 C #9 OPER. CAP* RANGE LENGTH (F) (in.) KNOB TYPE 61-89 34 61-89 40 61-89 18 61-89 18 65-92 24 61-91 34 61-90 21 61-89 28 LEVER ACTUATED*** 61-92 24 67-87 18 67-87 27 #6 #10 W OPER. CAP* RANGE LENGTH (F) (in.) KNOB TYPE 25-63 36 59-92 18 61-83 18 61-89 18 61-90 18 61-90 18 61-90 22 61-90 24 66-89 12 60-85 24 LEVER ACTUATED*** 61-90 24 65-91 24 65-91 36 ARR. CONTACT FLA** ROT. SEE FIG.# SHAFT LENGTH (in.) SPDT SPDT SPDT SPDT SPDT SPDT SPDT SPDT 20 20 25 25 25 30 20 20 1 8 2 7 3 4 9 10 .8 1.1 .9 .6 .9 1.0 .8 .6 HH22UD063 HH22UC064 HH22AD061 51DV660002 HH22QD064 51HK660011 51QF660002† HH22LB065 SPDT SPDT SPDT 25 25 25 5 6 5 - HH22GD061 51SW660004 HH22QD067 P/N *Bulb length included **Contact Rating FLA @120/240 V ***Thermostats have overtravel at each end of rotation and there is no control in overtravel area. †Has compressor lockout feature at tend of warm rotation. #8 #9 C C #10 C C W W #8 C W #4 W C C W #7 C W W #6 W #3 #2 #4 C C C C C W C W #1 C W W W C #11 ARR. CONTACT FLA** ROT. SEE FIG.# SHAFT LENGTH (in.) SPDT SPST SPST SPST SPDT SPDT SPST SPST SPST SPST 20 20 20 20 25 25 20 23 20 25 5 1 2 11 3 4 6 4 8 10 .6 .5 .5 1.9 .6 .5 .9 .9 .6 .8 SPST SPDT SPST 23 25 30 9 9 9 - P/N HH22UC067 51KR680058 51KY130956 HH22YB063 51PC680090 51PH129256 51EH660003 HH22GB062 HH22QB062 51NT42302007 HH22GB060 HH22QD066 51YC660007 *Bulb Length included. **Contact Rating FLA @120/240 V ***Thermostats have overtravel at each end of rotation and there is no control in overtravel area. 487 ROOM AIR CONDITIONER THERMOSTATS CAC COMPONENTS BELLOWS HEATER • BELLOWS HEATERS FOR GENERAL ELECTRIC RAC THERMOSTATS • USED ON UNITS WHERE A COLD CONTROL BOX CAUSES THERMOSTAT TO CONTROL POORLY VOLTS 115 230 P597 • 5 INCH LEADS • HEATERS MOUNT WITH 51PG098675 CLIP • LEADS TERMINATE IN.25 DOUBLE QUICK -CONNECTS HEATER RATING (WATTS) 2.8 2.7 P/N 51PG098642 51PG098517 TEMPERATURE SWITCH... SNAP ACTION • OPENS ON TEMPERATURE RISE • SPST CONTACT ARRANGEMENT • DISC TYPE • QUICK CONNECT TERMINALS • AUTOMATIC RESET • 125 VA PILOT DUTY P598 OPEN TEMP. (°F) 40 50 70 110 110 115 115 120 125 130 130 140 150 150 160 160 160 160 160 165 170 175 180 180 180 185 185 190 195 200 200 215 220 275 290 325 350 CLOSE TEMP. (°F) 32 40 60 85 90 85 90 90 90 90 100 100 110 130 105 110 110 120 145 120 110 120 140 140 160 145 145 150 155 160 135 175 175 230 250 280 280 FLA 120 VAC FLA 240 VAC 13 23 5.8 13 10 10 10 10 10 10 10 10 10 10 4.4 10 13 10 4.4 4.4 10 10 10 10 10 10 4.4 10 10 7.2 10 10 10 7.2 10 7.2 10 10 23 2.9 10 5 5 5 5 5 5 5 5 5 5 2.2 5 10 5 2.2 2.2 5 5 5 5 5 5 2.2 5 5 3.6 5 5 5 3.6 5 3.6 5 *ENC. - Enclosed bimetal; EX. - Exposed bimetal **Manual reset †1DPST contact arrangement. Flush mount. 488 INSERT DEPTH (in.) 3/8 3/8 3/16 3/8 3/8 11/32 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/16 5/32 3/8 3/8 3/8 3/8 3/8 3/8 3/16 3/8 3/8 13/32 HOLE SIZE (in.) 1-3/16 15/16 5/8 1-3/16 15/16 15/16 15/16 15/16 15/16 15/16 15/16 15/16 15/16 15/16 15/16 15/16 1-3/16 15/16 13/16 13/16 15/16 15/16 15/16 15/16 15/16 15/16 13/16 15/16 15/16 1-7/32 25/64 5/32 5/32 25/64 3/16 25/64 15/16 13/16 13/16 15/16 13/16 15/16 BIMETAL ENC. ENC. ENC. ENC. EXP. EXP. EXP. EXP. EXP. ENC. EXP. EXP. EXP. EXP. EXP. EXP. ENC. EXP. ENC. EXP. EXP. EXP. EXP. ENC. EXP. EXP. EXP. EXP. ENC. EXP. ENC. ENC. EXP. EXP. ENC. EXP. ENC. P/N HH17JB032 HH18HA050 HH18HA074 HH13HA210 HH18HA110 HH12HV115† HH18HA117 HH18HA120 HH18HA125 HH18HA127 HH18HA130 HH18HA141 HH18HA150 HH18HA129 HH12HA163** HH18HA161 HH12HA159 HH18HA160 HH12HA161 HH12HA120 HH18HA173 HH18HA176 HH18HA182 HH18HA194** HH18HA179 HH18HA186 HH12HA185 HH18HA191 HH18HA195** HH12HA199 HH18HA199** HH18HA215** HH12HA225 HH12HA275 HH18HA291** HH12HA325 HH18HA350** MISCELLANEOUS PARTS MISCELLANEOUS PARTS ROOM AIR CONDITIONER SERVICE CORDS • 1/4 IN. QUICK CONNECT TERMINALS ON POWER LEADS • RING TERMINAL ON GROUND WIRE • IVORY COLOR EXCEPT 51PC CORDS ARE GRAY P402 FIG. A FIGURE A B D FIG. B WIRE GAUGE 14 14 16 12 12 FIG. C FIG. D AMPS VOLTS 15 125 15 250 20 125 LENGTH (in.) 93 66 113 60 113 FIG. E FIG. F P/N 51SA400353 52BQ400424 60AA400084 51FA402483 60AA400094 FIG. G FIGURE E G WIRE GAGE 14 12 10 10 12 AMPS VOLTS 20 250 30 250 LENGTH (in.) 66 92 60 100 66 P/N 52BQ400434 51SW400063 51FL401524 51YA400593 52BO400444 ROOM AIR CONDITIONER FILTER The 51YA680001 polyurethane foam replacement room air conditioner filter measures 22-3/4 in. x 14-1/2 in. x 1/4 in. thick. It can be trimmed to fit most RAC’s in use today. P/N: 51YA680001 P729 489 TOTALINE® THERMOSTAT GUARDS THERMOSTAT GUARDS ® • Metal: beige • Plastic: beige or clear • Sizes fit most thermostats P593 • Solid and ring bases Metal • Have key lock • Virtually tamper proof P594 Plastic Metal WIDTH (in.) 3-7/8 5-1/4 5-1/4 6-3/8 6-3/8 6 6-1/4 7-1/4 6-3/4 HEIGHT (in.) 3-1/2 4-5/8 4-5/8 3-1/2 3-1/2 3-3/16 4-3/4 5-3/8 4-1/4 DEPTH (in.) 2-1/2 3 3-1/4 3 3-1/4 3-1/8 3 3-1/2 3-9/16 BASE Solid Solid Ring Solid Ring Ring Solid Solid Ring STYLE Beige Beige Beige Beige Beige Beige Beige Beige Beige P/N P269-0010 P269-0011 P269-0012 P269-0013 P269-0014 P269-0015 P269-0016 P269-0017 P269-0018 BASE Solid--Solid Solid Ring Solid Ring Solid Ring Solid Ring Ring Ring STYLE ClearBeige Clear Clear Beige Beige Clear Clear Beige Beige Clear Beige P/N P269-0001 P269-0002 Plastic WIDTH (in.) 3-7/8 3-7/8 5-1/4 5-1/4 5-1/4 5-1/4 6-3/8 6-3/8 6-3/8 6-3/8 8-1/4 8-1/4 490 HEIGTH (in.) 3-1/2 3-1/2 4-5/8 4-5/8 4-5/8 4-5/8 3-1/2 3-1/2 3-1/2 3-1/2 5-3/8 5-3/8 DEPTH (in.) 2-1/2 2-1/2 3 3-1/4 3 3-1/4 3 3-1/4 3 3-1/4 3-1/2 3-1/2 P269-0003 P269-0004 P269-0005 P269-0006 P269-0007 P269-0008 SWITCHES ROCKER SWITCHES P680 P679 FIG. A P682 P681 FIG. B FIG. C DESCRIPTION On-Off Action, SPST Contacts, 15 Amps @ 125 V, 10 Amps @ 250 V, 3/4 HP Rating @ 125/250 V, 1/4 In. Quick Connects, Indicator Light On-On Action, SPDT Contacts, 20 Amps @ 125 V/250 V, 1-1/2 HP Rating @ 125/250 V, 1/4 In. Quick Connects On-Off-Momentary On Action, SPDT Contacts, 15 Amps @ 125 V, 10 Amps @ 250 V 1/2 HP Rating @ 125/250 V, 1/4 In. Quick Connects On-Off Action, DPST Contacts, 15 Amps @ 125 V, 10 Amps @ 250 V, 3/4 HP Rating @ 250 V, 1/4 In. Quick Connects On-On Action, DPDT Contacts, 10 Amps @ 125 V, 5 Amps @ 250 V, 1/2 HP Rating @ 125/250 V, 1/4 In. Quick Connects On-Off Action, SPDT Contacts, 12 Amps @ 125 VAC, 6 Amps @ 250 VAC 3/16 In. Quick Connects On-Off Action, SPST Contacts, 6 Amps @ 125 V, 3 Amps @ 250 V, 1/4 HP Rating @ 125/250 V, 1/4 In. Quick Connects Lighted, On-Off Action, SPST Contacts, 16 Amps @ 125 V, 20 Amps @ 250 V, 1/4 In. Quick Connects FIG. D FIGURE A P/N HR51680001 51KX680007 HR54ZZ001 B HR54AF042 HR54ZJ001 HR54ZD001 C D HR51ZA130 (125 V) - HR54ZA001 (250 V) - HR54ZA002 ROTARY SWITCHES P683 FIG. E FIG. F P684 DESCRIPTION On-Off Action, SPST Contact, 6 Amps @ 125 V, 3 Amps @ 250 V, 1/4 In. Quick Connects On-On Action, SPDT Contacts, 6 Amps @ 125 V, 3 Amps @ 250 V, 1/10 HP Rating @ 125 V, 1/4 HP Rating @ 250 V, .25 Shaft, Push In Connections On-On Action, SPDT Contacts, 20 Amps @ 125/250 V, 1 HP Rating @ 125 V, 2 HP Rating @ 250 V, .25 Shaft, 1/4 In. Quick Connects Off-1 On-1 & 2 On Action, 35 Amps @ 125/250 V, 1 HP Rating @ 125 V, 2 HP Rating @ 250 V, .25 Shaft, Screw Connections Off-1 On-1 & 2 On-2 & 3 On Action, 20 Amps @ 125/250 V, 1-1/4 HP Rating @ 125 V, 2 HP Rating @ 250 V, .25 Shaft, 1/4 In. Quick Connects P685 FIG. G FIGURE P/N E HR56BZ030 F HR56KH277 HR56KE044 G HR56WL001 HR56ZZ010 491 SWITCHES PUSH BUTTON SWITCHES P687 FIG. A P686 P688 P689 FIG. C FIG. B P690 FIG. D DESCRIPTION Lighted, normally Off-Momentary On Action, SPST Contacts, 8.5 Amps @ 125 V, 1/4 In. Quick Connects, Indicator Light Lighted, On-Off Action, DPST Contacts, One Pole N.O. and One Pole N.C., 1/4 In. Quick Connects On-Off Action, SPST Contacts, 3 Amps @ 125 V, 1 Amp @ 250 V, Solder Terminals Normally Off-Momentary On Action, SPST Contacts, 3 Amps @ 125 V, 1 Amp @ 250 V, Leads Normally On-Momentary Off Action, SPST Contacts, 6 Amps @ 125 V, 3 Amps @ 250 V, 1/4 In. Quick Connects Normally On-Momentary Off Action, SPST Contacts, 10 Amps @ 125/250 V, Screw Connections On-Off Action, TPST Contacts, 10 Amps @ 125/250 V, Screw Connections On-Off Action, DPST Contacts, 16 Amps @ 125 V, 8 Amps @ 250 V, Screw Connections On-Off Action, SPST Contacts, 20 Amps @ 125 V, 10 Amps @ 250 V, 3/4 HP Rating @ 125 V/250 V, 1/4 In. Quick Connects (Door Switch) FIGURE FIG. E P/N HR54ZA020 A HR52ZD040 41CA680147 HR54BV001 B HR54BV010 HR54KX030 C HR54KY030 D HR54BC040 E HR54ZA003 TOGGLE SWITCHES FIGURE ACTION # CONTACT ARRANGEMENT F ON-OFF ON-ON ON-ON ON-ON ON-ON ON-OFF-ON ON-(M)ON (M)ON-OFF-(M)ON ON-OFF ON-ON ON-ON ON-OFF-ON ON-OFF-ON SPST SPDT SPDT SPDT SPDT SPDT SPDT SPDT DPST DPDT DPDT DPDT DPDT H ON-OFF DPST FIG. F P691 FIG. H P692 492 # (M) stands for momentary. *Rated 30A, 2HP @ 480V. CONTACT RATING AMPS HP 125V 250V 125V 250V 15 10 1/2 3/4 6 3 1/4 1/4 6 3 1/4 1/4 15 10 3/4 3/4 15 15 1/2 1 15 7.5 1/2 15 10 3/4 3/4 6 3 15 10 3/4 3/4 15 15 1/2 1 15 10 3/4 3/4 15 10 3/4 3/4 20 MA - x5 - 2 TERMINAL CONN. P/N 1/4″ Q.C. LEADS 1/4″ Q.C. SCREW SOLDER SCREW 3/16″ Q.C. 1/4″ Q.C. SCREW SOLDER 1/4″ Q.C. 1/4″ Q.C. 1/4″ Q.C. HR53ZA035 HR53ZE050 HR53AE070 HR53BE019 HR53ME040 HR53VR026 HR53ZE010 HR53ED010 HR53SF015 HR53MJ010 HR53VK121 HR53VK120 HR53ZK001 SCREW HR53KA040* SWITCHES MICRO SWITCHES P694 P697 FIG. B FIG. A P695 P698 FIG. C OPER. FORCE (OZ.) A 6-14 B 8 C 2.5 D 5 E 6 F 35 FIG. D P696 FIG. E FIG. P699 CONRELEASE ELECTRICAL TACT FORCE (OZ.) RATING ARR. 10A @ 4 SPDT 125/250V 5A @ 24V 2 SPDT 7A 120/240V 30A @ 125-460V 3/4 HP @ .5 SPDT 120V 1-1/2 HP @ 240V 10A @ 125V 1 SPDT 1 HP @ 125V 2 HP @ 250V 15A @ 1 SPDT 125-460V 8 SPDT 570 VA P/N HR54MA010 * HR54MA020 * HR64TE040 HR64TE010 ** HR64TE038 HR64TE020 *Miniature type. **Used in H-W S952 step controller. †Used in H-W S984 step controller. FIG. F MISCELLANEOUS SWITCHES • • • • SLIDE ACTION ON-OFF (SPST) SWITCH RATED 6 AMPS @ 125 V 3 AMPS @ 125V 6 IN. LEADS P/N: • • FURNACE DOOR INTERLOCK SWITCH SPST-NORMALLY OPEN 16 AMPS @ 125/250 V P/N: • 51TJ660012 10 AMPS @ 125/250 V P/N: P700 58SGB4310407 HR54ZA101 P701 INDICATOR LIGHTS FIG. G P702 FIG. G FIG. H P703 H I J VOLTAGE 24 24 120 120 240 240 115 230 24 24 24 12 LENS COLOR RED AMBER RED AMBER RED AMBER RED RED RED GREEN AMBER WHITE, HOLE SIZE (IN.) 1/2 1/2 1/2 1/2 1/2 1/2 1 1 1/2 1/2 1/2 1/2 TERM. CONN. 3/16″ Q.C 3/16″ Q.C 3/16″ Q.C 3/16″ Q.C 3/16″ Q.C 3/16″ Q.C 1/4″ Q.C 1/4″ Q.C 3/16″ Q.C 3/16″ Q.C 3/16″ Q.C LEADS P/N HY19AZ025 HY19AZ024 HY19AZ002 HY19AZ004 HY19AZ007 HY19AZ009 HY19UC018 HY19UC014 41CA680143 41CA680144 41CA680145 31TC113750 P705 P704 FIG. I FIG. J 493 TEMPERATURE ACTUATED SWITCHES TEMPERATURE SWITCH... SNAP ACTION • • • • P612 • • SPST INSERT DEPTH: 3/8 IN. OPENS ON TEMPERATURE RISE FLA: 10 @ 120 VAC 5 @ 230 VAC HOLE SIZE: 15/16 IN. HEIGHT MOUNTED: 11/16 IN. OPEN TEMP (°F) CLOSE TEMP (°F) P/N 100 120 125 130 135 140 145 150 155 155 165 170 175 175 180 180 190 195 195 200 220 165 195 205 210 200 330 340 85 90 90 95 95 100 105 110 105 115 125 130 135 130 140 150 155 130 150 155 165 170 160 250 300 HH19ZA100 HH19ZA120 HH19ZA125 HH19ZA130 HH19ZA135 HH19ZA140 HH19ZA145 HH19ZA150 HH19ZA156 HH19ZA155 HH19ZA165 HH19ZA170 HH19ZA175 HH19ZH175* HH19ZA181 HH19ZA180 HH19ZA190 HH19ZA195 HH19ZH195* HH19ZA201 HH19ZA220 HH680302 HH680305 HH680306 HH680307** HH680311 HH680313** HH680315 • • • SPDT SWITCHING 1-9/16 IN. MOUNTING HOLE SPACING AUTO RESET P613 TEMP (°F) 1-3 1-3 OPEN CLOSE 61 75 80 65 95 87 105 97 118 110 110 90 120 90 125 95 135 110 145 115 155 125 160 130 170 130 170 140 180 140 185 155 205 175 230 190 AMP.RTG. INSERT @ 240 V DEPTH (in.) FLA RES. 2.9 5 3/8 2.9 5 7/16 2.9 5 7/16 2.9 5 7/16 2.9 5 7/16 5 25 3/8 5 25 3/8 5 25 3/8 5 25 3/8 5 25 3/8 5 25 3/8 5 25 3/8 3.6 25 3/8 5 25 3/8 2.9 25 5/32 5 25 3/8 5 25 3/8 3.6 25 5/32 HOLE SIZE (in.) 1-1/16 1-1/16 1-1/16 1-1/16 1-1/16 15/16 15/16 15/16 15/16 15/16 15/16 15/16 1-7/32 15/16 13/16 15/16 15/16 13/16 P/N HH18HD075 HH18HD070 HH18HD117 HH18HD105 HH18HD118 HH18HV110 HH18HV120 HH18HV125 HH18HV135 HH18HV145 HH18HV155 HH18HV160 HH12HC171 HH18HV170 HH12JC180 HH18HV185 HH18HV205 HH12HC230 *FLA 14 @ 120 VAC and 240 VAC. **Enclosed Disk. TEMPERATURE SWITCH... SNAP ACTION, FLUSH MOUNT • • • • • CLOSES ON TEMPERATURE RISE SPST. CONTACT ARRANGEMENT DISC TYPE AUTOMATIC RESET • SPST. CONTACT ARRANGEMENT SWITCH RATING: 25 AMPS NON-INDUCTIVE, 25 VA PILOT DUTY @ 120-277 VAC P615 P613 TEMP (°F) OPEN CLOSE 95 110 116 190 125 135 175 210 FLA 120 VAC 13 1 10 7.2 FLA 240 VAC 10 1 5 3.6 *Flush mount over hole specified. **Flush mount on surface. INSERT DEPTH (in.) * ** 3/8 7/16 HOLE SIZE (in.) 1-1/32 15/16 1-7/32 TEMP (°F) P/N HH12HC009* HH17JA110** HH19ZB175 HH12HB210 RESET CAPIL. LENGTH (in.) ELEC. CONN. CLOSE 160 190 225 225 240 140 150 185 185 200 AUTO. AUTO. AUTO. MAN. AUTO. 24 48 48 30 66 QC QC QC QC SCREW HH22HA141 HH22HA191 HH22HA225 HH22HA231* HH22HA240 285 245 AUTO. 96 QC HH22HA284 *SPDT contact arrangement. 494 P/N OPEN TEMPERATURE ACTUATED SWITCHES TEMPERATURE SWITCH ... FLUSH MOUNT • FLUSH SWITCH SURFACE • FLUSH SWITCH SURFACE • SNAP ACTION • SNAP ACTION • EXPOSED BIMETAL DISC • SEALED CONTACTS • WITH LEADS P618 P616 CONTACT RTG. (FLA) @ OPEN CLOSE 120 V 240 V CONTACT ARR 40 45 55 60 52 35 65 70 *** 25* 10 10 *** 25* 5 5 SPST SPST SPST SPST 36 20 60 60 HH18HB040 HH22HB078 HH22HB075† HH22HB076† 65 70 80 90 85 28 80 65 120 65 6 10 5.8 6 5.8 3.6 5 2.9 3.6 2.9 SPST SPST SPST SPST SPDT 48 60 45 48 27 HH18JA066 HH22HB077† HH18HA080S HH18JB086**† HH18HC071 105 115 278 290 43 100 178 210 6 *** 13 25* 3.6 *** 10 25* SPST SPST SPST SPST 36 36 30 72 HH18JA105 HH18HA116 HH18HB278 HH18HA210 TEMP (°F) LEAD LENGTH (in.) *Non-inductive rating. **Clip mounted. ***Contacts rated for electromechanical & electronic defrost control. †Contacts make on temperature rise. CONTACT RTG. (FLA) @ OPEN CLOSE 120 V 240 V CONTACT ARR. 45 47 130 140 150 35 57 100 110 110 10 10 10 5 5 35 35 5 SPST SPST SPST SPST SPST QC QC SCREW SCREW QC HH22HB078 HH18HB052† HH18HA132 HHI8HA139 HHI8HA149 150 155 175 190 140 110 110 120 140 125 - 35 35 35 35 - SPST SPST SPST SPST SPST SCREW SCREW SCREW SCREW HH18HA152 HH18HA155 HH18HA178 HH18HA192 HH680101 170 160 190 130 145 150 - - SPST SPST SPST TEMP (°F) P/N ELEC. CONN. P/N HH680102 HH680103 HH680104 †Contacts make on temperature rise. TEMPERATURE SWITCH ... TUBE MOUNTED • TUBE MOUNTED • SNAP ACTION • SEALED CONTACTS P617 TEMP (°F)) CONTACT RTG. (FLA) TUBE DIA. (in.) CONTACT ARR. LEAD LENGTH (in.) OP. CL. @ 120 V @ 240 V 3/8 3/8 3/8 3/8 3/8 25 30 65 80 80 53 45 35 27 27 5.8 5.8 13 ** ** 2.9 2.9 10 ** ** SPDT SPST SPST SPST SPST 36 48 48 95 95 HH18HC025† HH18HB030 HH18HA036 HH18HA094 HH18HA098‡ 3/8 3/8 3/8 3/8 3/8 80 85 90 100 140 40 65 80 135 125 ** 5.8 5.8 5.8 5.8 ** 2.9 2.9 2.9 2.9 SPST SPST SPST SPST SPST 48 45 35 24 24 HH18HH091 HH18HA086 HH18HA080 HH18HA100† HH18HA142 3/8 1/2 1/2 1/2 1/2 50 5 25 60 61 27 45 53 40 35 SPST SPST SPDT SPST SPST QC QC 102 75 36 HH18HA081 HH18JA004† HH18HC102† HH18HA047 HH18JA062 1/2 1/2 1/2 1/2 1/2 65 65 65 80 85 28 35 45 27 65 SPST SPST SPDT SPST SPST 48 36 36 55 19 HH18JA067 HH18HA035 HH18HC065 HH18HA095‡ HH18HA054 ** ** 125VA 125VA 5.8 2.9 5.8 2.9 6 3.6 6 13 5.8 ** 1.5 3.6 10 2.9 ** 1.5 P/N TUBE TEMP (°F) DIA. (in.) OR CL. 5/8 5/8 5/8 5/8 5/8 5/8 5/8 5 45 28 48 65 35 65 45 85 65 85 65 1265 1651 CONTACT RTG. (FLA) @ @ 120 V 240 V 125VA 125VA 13 10 5.8 2.9 5.8 2.9 5.8 2.9 5.8 2.9 13 10 CONTACT ARR. LEAD LENGTH (in.) SPST SPST SPST SPST SPDT SPDT SPST QC 43 48 36 63 18 36 P/N HH18JA005t† HH18HA028† HH18HA059 HH18HA069 HH19HC263* HH18HA085 HH18HA265 *Clip mounted. **Contacts rated for electromechanical & electronic defrost control. †Contacts make on temperature rise. ‡Used on aluminum tube. 495 TEMPERATURE ACTUATED SWITCHES NON-ADJUSTABLE TEMPERATURE ACTUATED SWITCHES • VAPOR FILLED • REMOTE BULB NON-ADJUSTABLE THERMOSTAT • CONTACTS RATED 20 FLA @ 240 VOLTS • SPST CONTACTS OPEN ON TEMPERATURE RISE • FIXED DIFFERENTIAL P619 CONTACTS (°F) OPEN CLOSE 26 35 72.5 55 39 67.5 DIFFERENTIAL (°F ) 29 4 5 CAPIL. LENGTH (in.) 36 35 18 P/N P623 50BB660001 HH22UA035 HH22UA070 CONTACTS CONTACT RTG. CAPIL. BULB (°F) (FLA) @ LENGTH SIZE P/N (ft) (in.) OPEN CLOSE 120V 240V 275 200 16 8 3 3/8 x 3 HH22YC275 SPDT SWITCHING 3 2 1 • DPST SWITCHING ACTION WITH ONE SIDE COMMON TEMP.SETTINGS (°F) 2-1 MAKE 2-3 MAKE 15 20 36 40 87 35 45 42 44 91 DIFFERENTIAL (°F) 20 25 6 4 4 CAPIL. LENGTH (in.) 42 27 24 27 18 • 24 VOLT MAXIMUM AC ROSS TERMINALS P/N HH22UC034 HH22UC020 HH22UC038 HH22UC040 HH22UC090 • Tl CONTACTS CLOSE @ 50 ° F T2 CONTACTS CLOSE @ 54 ° F P/N: P339-2 HH21PD055 ADJUSTABLE REMOTE BULB THERMOSTATS P622 P621 FIG. B FIG. C P627 P626 P624 FIG. D FIG. F FIGURE CAPILLARY LENGTH (ft) BULB SIZE (in.) RANGE (°F) DIFFERENTIAL (°F) CONTACT ARR. B C D G G E 6 10 4 4 3 2 3/8 x 5.5 3/8 x 5 3/8 x 3.7 3/8 x 7.2 3/8 x 7 3/8 x 5 -20 to 70 -10 to 55 0 to 50 50 to 70 58 to 85 60 to 96 6 5 6 2 3 3 SPST* SPST* SPST* SPDT SPDT SPDT *Opens on temperature rise. **Close on temperature rise. 496 FIG. G CONTACT RATING. (FLA) @ 120 V @ 240 V 25 30 6 20 20 20 20 20 P/N HH22YA070 HH22VA040 HH22PA050 HH22UA078 HH22UZ101 50BQ580-07 TEMPERATURE ACTUATED SWITCHES ADJUSTABLE REMOTE BULB THERMOSTATS 3 2 1 P628 P630 P629 FIG. A • • • • FIG. B STAGED REMOTE BULB THERMOSTATS 2, 3 AND 4 -SPDT TYPES AVAILABLE 140° F MAX. BULB TEMPERATURE 15 FT CAPILLARY FIGURE RANGE (°F) A 20 to 80 10 to 80 10 to 80 B 55 to 105 C -15 to 45 25 to 61 35 to 62 SWITCH DIFFERENTIAL (°F) 3.5 3 3 5 8 4 4 • • • • • FIG. C TWO STAGE REMOTE BULB THERMOSTATS TWO SPST SWITCHES OPEN ON A DROP IN TEMPERATURE 7-1/2 FT CAPILLARY 160° F MAX. BULB TEMPERATURE CONTACT RATING: 8A @ 120/240 V INTERSTAGE DIFFERENTIAL (°F) 6 3.5 2.5 13 - CONTACT ARR. 2-SPDT 3-SPDT 4-SPDT SPST SPDT SPDT CONTACT RATING. (FLA) @ @ 120 V @ 240 V 16 8 10 5 10 5 5 20 20 • • SINGLE STAGE REMOTE BULB THERMOSTATS SCREWDRIVER ADJUSTABLE FOR LIMITED ACCESS APPLICATIONS BULB SIZE (in.) 3/8 x 5.6 3/8 x 4 3/8 x 4 1/2 x 3 - CAPIL. LENGTH (in.) 36 30 33 P/N HH24CZ020 HH24CZ021 HH24CZ022 HH29AA080 HH22QA040* HH22UC063** HH22UC062* *Closes on temperature drop. **See contact arrangement diagram by photo, Figure C. 497 TEMPERATURE ACTUATED SWITCHES REMOTE BULB THERMOSTATS P631 • • FIGURE D E F FIG. E • ACCURATELY REGULATES TEMP. OF AIR OR LIQUIDS IN DUCTS, PIPES OR TANKS WHERE CONTROLLER MUST BE PLACED OUTSIDE THE SENSING AREA HH22AN100 AND HH22AL090 ARE TWO STEP CONTROLS. HH22AN100 HAS AN ADJUSTABLE INTERSTAGE DIFFERENTIAL OF 3 TO 10 DEGREES. HH22AL090 HAS A FIXED INTERSTAGE DIFFERENTIAL OF 2-1/2 DEGREES. RANGE ( °F) DIFFERENTIAL ( °F) CONTACT ARR. -30 to 90 0 to 100 0 to 100 55 to 90 55 to 90 -20 to 50 20 to 75 33 to 55 Adj. 5 to 40 Adj. 3 to 10 Non-Adj.3 Non-Adj. 2 Non-Adj. 2 Adj.3 to 20 - SPDT SPDT 2-SPDT SPDT 2-SPDT SPST SPST SPST 50 to 200 Adj. 6 to 24 SPDT *HH22AL090, HH22AC090 do not have an enclosure. 498 P633 P632 FIG. D FIG. F REMOTE BULB TEMPERATURE CONTROLS WITH SPST CONTACTS THAT CLOSE ON TEMPERATURE RISE • REMOTE BULB TEMPERATURE CONTROL • BULB WELL IS SUPPLIED WITH CONTROL • HH22PB030 AND HH22PB036 ARE MANUAL RESET DEVICES • MAY BE MOUNTED IN ANY POSITION • REQUIRED WELL IS PART NO. HL79PZ001 CONTACT RATING. (FLA) @120 V @240 V 7.4 3.7 8 5.1 8 5.1 3.2 1.6 8 5.1 7.4 3.7 13 6.5 7.4 3.7 16 8 CAPILLARY LENGTH (ft) BULB SIZE (in.) MAX. TEMP ( °F) 8 20 20 5 5 10 8 20 3/8 x 5.0 1/2 x 4.5 1/2 x 4.5 5/16 x 11.7 1/2 x 11.7 3/8 x 5.7 3/8 x 7.2 5/16 x 11 155 125 125 135 135 120 120 120 HH22PC020 HH22AG106 HH22AN100 HH22AC090* HH22AL090* HH22PB030 HH22PB032 HH22PB036 20 3/8 x 4 290 HH680-608 P/N TEMPERATURE ACTUATED SWITCHES REMOTE BULB PROPORTIONAL TEMPERATURE CONTROLLER • • • • • PROVIDES CONTROL OF LOW VOLTAGE VALVE OR DAMPER MOTORS USED IN 24 VOLT CIRCUIT AMBIENT COMPENSATED 135 OHM POTENTIOMETER HONEYWELL TYPE T991A • • • • • P635 PROVIDES CONTROL OF LOW VOLTAGE VALVE OR DAMPER MOTORS USED IN 24 VOLT CIRCUIT AMBIENT COMPENSATED 135 OHM POTENTIOMETER HONEYWELL TYPE T915, PENN TYPE A80 P631 FIG. B FIG. A SET POINT ADJ. RANGE ( °F) 0 to 100 0 to 100 10 to 90 15 to 90 FIGURE A B THROTTLING RANGE (°F) 3 to 30 3 to 30 7 to 38 7 to 38 MAX.BULB TEMP ( °F) 125 125 130 200 CAPILLARY LENGTH (ft) 20 9.6 11 20 SIZE OF BULB (in.) 1/2 x 4 1/2 x 76 11/16 x 7 1/2 x 4 P/N HH23AG045 HH22AG103* HH23AG030 HH23AG085 *Control has 76 inch sensing element. CONTROL BULB • • D C CONTROL BULB WELLS FOR USE WITH TEMPERATURE CONTROLLERS BUSHING INCLUDED B A FOR BULB DIA. (in.) 5/16 3/8 3/8 1/2 1/2 1/2 A 13.0 6.3 7.6 8.7 8.7 5.7 DIMENSIONS (in.) B C 11.5 1.2 5.0 .7 5.8 1.4 4.2 3.7 4.2 3.7 4.2 .7 D .4 .4 .4 .7 .7 .7 THREAD SIZE NPT 1/2-14 1/2-14 1/2-14 1/2-14 3/4-14 1/2-14 P/N HL79PZ001 30HH406102 HL79ZZ002 HL79MZ001 HL79MZ005 HL79MZ007 499 TEMPERATURE ACTUATED SWITCHES AQUASTAT CONTROLLERS P/N P672-L4006 P/N P672-L6006C • • TOTALLY ENCLOSED MICRO SWITCH SNAP-ACTING SWITCHES OPERATE ON TEMPERATURE RISE TO SET POINT. VISIBLE CONTROL POINT SCALE AND EXTERNAL ADJUSTMENT SCREW PERMIT EASY SETTING. HORIZONTAL OR VERTICAL INSERTION AND DIRECT OR WELL IMMERSION OF SENSING ELEMENT. • • • • • • OPERATE IN RESPONSE TO TEMPERATURE CHANGES IN HYDRONIC HEATING SYSTEMS. PROVIDES SPDT SWITCHING FOR THREE-WIRE APPLICATIONS. COMBINES CIRCULATOR CONTROL WITH HIGH AND LOW LIMITS. HORIZONTAL OR VERTICAL SURFACE MOUNTING. VISIBLE CONTROL POINT SCALE AND EXTERNAL ADJUSTMENT SCREW PERMIT EASY SETTING. P4320 P/N P672-L7124U UNIVERSAL OIL ELECTRONIC AQUASTAT CONTROLLER • • • • PROVIDES ELECTRONIC TEMPERATURE SENSING IN A UL LIMIT-RATED CONTROL WITH A SINGLE SENSING PROBE. CONTROLS CIRCULATOR, OIL BURNER, AND BOILER TEMPERATURE. REPLACES THE L8124A, L8124C, L8148A CONTROLLERS. THE L7124U HAS A CASE THAT CAN BE CONVERTED FOR EITHER HORIZONTAL OR VERTICAL MOUNTING. PART NUMBER P672-L4006A P672-L4006B P672-L6006C P672-L7124U HONEYWELL PART NUMBER L4006A1009 L4006B1007 L6006C1018 L7124U1003 P4321 SWITCHING RELAYS P/N P673-RA889A SWITCHING RELAY (HYDRONIC) P/N P673-R8845A UNIVERSAL SWITCHING RELAY (HYDRONIC) • • • • • • • • • • HIGH LOAD SWITCHING RELAY. TROUBLESHOOTING LED. REPLACEABLE TRANSFORMER FUSE. LONG LIFE DC RELAY DRIVE CONTROL TECHNOLOGY. RELAY FOR USE WITH EXTERNAL 24 VAC OR 24 VDC SUPPLY, WITH LINE-VOLTAGE CONTROL, OR WITH INTERNAL 24-V TRANSFORMER SUPPLY. • REPLACEABLE, SOCKETED RELAY. TWO TROUBLESHOOTING LED’S. PUSH-TO-TEST BUTTON. REPLACEABLE TRANSFORMER FUSE. LOW VOLTAGE CONTACTS FOR POWERPILE APPLICATIONS. RELAYS CAN BE USED WITH EXTERNAL 24-VAC OR 24-VDC SUPPLY, LINE-VOLTAGE CONTROL, OR WITH INTERNAL 24-V TRANSFORMER. P4325 PART NUMBER P673-RA889A P673-R8845A 500 HONEYWELL PART NUMBER RA889A1001 R8845U1003