Preview only show first 10 pages with watermark. For full document please download

Fastsmp For Network Operators

   EMBED


Share

Transcript

TM Infinera FastSMP More Reliable, Less Cost 1 | © 2013 Infinera The perfect storm – Are you ready? US fiber network Hurricane Sandy: Multiple cuts 5 cuts / day / region 100 nation-wide 17% of all fiber cuts 6 concurrent fiber cuts SP customers demand topology maps Google Earth KMZ files 2 | © 2013 Infinera Source: FCC / UC Davis Feb 2013, US SP data, Intermedia Journal Dec 2011 Planning for a resilient network 1 2 3 3 | © 2013 Infinera Multi-failure backups Single failure recovery no longer sufficient Fast Recovery Deterministic behavior, within 50 milliseconds Minimal Costs Intelligent sharing of backup resources without losing availability Recovery mechanisms for networks Multi-failure backups Fast Recovery Minimal Costs Optical SONET/SDH: 1+1 Protection Single failure scenario Sub 50ms recovery on failure Dedicated backup resource Packet IP/MPLS: MPLS Fast Re-Route (FRR) Multi-failure scenarios Sub 50ms for limited scenarios Shared bandwidth, Packet layer $$$ Digital OTN: Software Mesh Restoration Multi-failure scenarios Up to few seconds recovery on failure Shared bandwidth, Transport layer Digital OTN: FastSMP™ Hardware Shared Mesh Protection Multi-failure scenarios Sub 50ms recovery on failure Shared bandwidth, Transport layer More Reliable 4 | © 2013 Infinera Less Cost Introducing FastSMP™ Industry’s first hardware-accelerated fast shared mesh protection Deterministic Performance: Sub 50ms failure recovery via dedicated hardware Enhanced Availability: Automatic multi-failure network-wide backup via network intelligence Lower Capital Costs & Operations: Shared backups via cost-effective transport layer Controller Client Card Fabric Line-side Card DTN-X 5 | © 2013 Infinera All existing (and future) deployments are ready day 1 26% of all LH 100 WDM ports ever sold in the industry are on DTN-X FastSMP™ processor built into all shipped DTN-X boards Enabled via simple software upgrades 6 | © 2013 Infinera Source: Dell’Oro Research 2013 Pacnet selects DTN-X for mesh submarine network Now hardware-ready for FastSMP™ 46000 km of fiber 23 data centers 2012 winner for service excellence Andy Lumdsen, CTO, Pacnet Pacnet’s unique position is its ability to offer a true long haul submarine mesh architecture on its core network within the APAC region. Enabling hardware accelerated FastSMP will give Pacnet a clear advantage in offering fully protected services and restoration capability for our customers. 7 | © 2013 Infinera FastSMP™ solution components Network Planning System DTN-X w/FastSMP™ Processor Plan with Infinera NPS for multi-failures GMPLS Control Plane Pre-provisioned in hardware for <50ms activation A B Real-time backup path re-computation C SPs like Pacnet moving to mesh architectures to take advantage of new transport protection schemes D 8 | © 2013 Infinera E F G Slide show mode only FastSMP™ in action FastSMP™ Processor table Service 1 = Working Path AE Protection = 1+1 Failure 1 Backup ADE Failure 2 Backup ABFE  1+1 Failure 3 Backup ABCGFE Plan with Infinera NPS for multi-failures Online optimization w/GMPLS at Transport Hardware activation <50ms across network Service 2 = Working Path AD Failure 1 Backup AD A B C Service 2 High Priority Service 1 Low D 9 | © 2013 Infinera E F G Shared backup = 50% fewer line cards than 1+1 on AD Slide show mode only Vision: FastSMP™ with Instant Bandwidth ™ An Infinite Pool of Intelligent Bandwidth Dynamically activate in real-time on new demand / failure FastSMP™ Processor table Service 1 = Working Path AE Failure 1 Backup ADE Link CG = Running hot…..notify of possible use Activate 100G slice on CG with Instant Bandwidth Failure 2 Backup ABFE Failure 3 Backup ABCGFE A B C 1 2 Nov 12 launch Instant Bandwidth enabled Line Card 100G ACTIVE 100G ACTIVE 100G ACTIVE D 10 | © 2013 Infinera E F G 100G ACTIVE 100G Latent Enabling multi-tiered service levels Network Service Protection for Recovery in Pre-emptible Premier 3 failures < 50ms No Elite 2 failures < 50ms 2nd backup Protected 1 failure < 50ms 1st backup Restorable 2 failures Not defined Only backups Unprotected 0 failures NA No Best effort 0 failures NA Yes Service differentiation for higher revenues 11 | © 2013 Infinera SMP saves 30% over 1+1 Protection 10000 100G WDM Protection Interface Count 1+1 SMP 8750 8000 6000 4000 2000 6400 6270 4630 2660 3480 4540 3240 2320 1870 0 SMP Savings Year 1 Year 2 Year 3 Year 4 Year 5 30% 33% 30% 28% 27% While being more reliable than 1+1 protection 12 | © 2013 Infinera Source: ACG Research, 2013 Large network, 80+ nodes Industry impetus on Shared Mesh Protection ITU – Q9 / SG15 G.SMP G.808.3 G.ODUSMP Documents under “Last Call” Documents on Two current drafts Standards Track Requirements for SMP Supporting SMP in MPLS-TP 13 | © 2013 Infinera FastSMPTM: Helping build a more resilient Internet Industry’s first hardware-accelerated fast shared mesh protection Deterministic Performance: Sub 50ms failure recovery via dedicated hardware Enhanced Availability: Automatic multi-failure network-wide backup via network intelligence Lower Capital Costs & Operations: Shared backups via cost-effective transport layer 14 | © 2013 Infinera Deterministic Network Resilience without the Expense  www.infinera.com/go/fast Thank You www.infinera.com 15 | © 2013 Infinera FastSMP™ pre-emption and conflict resolution A Working Path AB, 300G B 1 Real-life networks Multiple backups ensure survivability, much better protection than 1+1 Multiple priority levels per service demand (not just link) 2 Working Path DC, 400G D C Failure 1 Action 1 Failure 2 Action 2 For backup paths 1+1 = 8 line cards SMP = 6 line cards Failure X Action X 25% savings w/SMP Service Demand N Hardware activation 16 | © 2013 Infinera Plan with Infinera NPS Extensible to controller for periodic optimization Thank You www.infinera.com 17 | © 2013 Infinera