Preview only show first 10 pages with watermark. For full document please download

Fbq-c Technical Data

   EMBED


Share

Transcript

Indoor Units FBQ-C7VEB air conditioning systems technical data Indoor Units FBQ-C7VEB air conditioning systems technical data • Indoor Units • R-410A • FBQ-C7VEB TABLE OF CONTENTS FBQ-C7VEB 1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 For indoor units only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 3 3 Safety device settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 4 Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 5 Dimensional drawing & centre of gravity . . . . . . . . . . . . . . . . . . . . . . . . 7 Dimensional drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Centre of gravity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 6 Piping diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 7 Wiring diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Wiring diagram 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Sound data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Sound pressure spectrum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Sound power spectrum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 9 Fan characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 10 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Installation method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Filter installation method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Switch box connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 • Split Sky Air • Indoor Units 13 21 22 1 • Indoor Units • R-410A • FBQ-C7VEB 1 t i y n k BU S E V r a7t o 0C i o 1- ld 4Q npB- RFS•I Features Reduction in power consumption thanks to DC inverter fans • Home leave operation saves energy during absence • Improved comfort thanks to 3-step airflow control • Whisper quiet operation: down to 26 dBA sound pressure level • Maximum external static pressure (ESP) is 100Pa • 1 • Possibility to change ESP through wired remote control allows optimisation of the supply air volume Standard air filter: removes airborne dust particles to ensure a steady supply of clean air • 1 • Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible Easy installation thanks to automatic air flow adjustment towards nominal air flow rate • • Energy efficient: up to class A energy labels Built-in drain pump as standard increases reliability of the drain system optional via wired remote control 2 standard 3 steps optional • Split Sky Air • Indoor Units • Indoor Units • R-410A • FBQ-C7VEB 2 Specifications 2-1 For indoor units only Nominal input (Indoor only) Dimensions FBQ71C7VEB FBQ100C7VEB FBQ125C7VEB FBQ140C7VEB 0.14 0.14 0.35 0.35 0.35 0.35 0.35 Heating kW 0.14 0.14 0.35 0.35 0.35 0.35 0.35 FBQ35C7VEB FBQ50C7VEB FBQ60C7VEB FBQ71C7VEB Colour Non painted Material Galvanised steel Packing FBQ100C7VEB FBQ125C7VEB FBQ140C7VEB Height mm 355 355 355 355 355 355 355 mm 920 920 1,220 1,220 1,620 1,620 1,620 Depth mm 900 900 900 900 900 900 900 Height mm 300 300 300 300 300 300 300 Width mm 700 700 1,000 1,000 1,400 1,400 1,400 Depth mm 700 700 700 700 700 700 700 Unit kg 25 25 34 34 45 45 45 Packed Unit kg 28 28 41 41 53 53 53 440 440 740 740 1,140 1,140 1,140 3 3 3 3 3 3 3 mm 1.75 1.75 1.75 1.75 1.75 1.75 1.75 4 4 7 7 11 11 11 m² 0.148 0.148 0.249 0.249 0.383 0.383 0.383 16 16 16 16 16 16 16 mm Dimensions Length mm Nr of Passes Face Area Nr of Stages Tube type Fin Hi-XSS (7) Type Symmetric waffle louvre Treatment Hydrophilic Fan Type Air Flow Rate Cooling Sirocco fan High Low m³/min 11 11 15 15 23 28 28 Heating High m³/min 16 16 18 18 32 39 41 Low m³/min 11 11 15 15 23 28 29 Max High Pa 100 100 100 100 100 100 100 Standard Pa 30 30 30 30 40 50 50 Motor Quantity 1 1 1 1 1 1 1 Quantity Fan m³/min 1 1 2 2 3 3 3 16 16 18 18 32 39 39 Model Brushless DC Number of steps Motor Fan Speed (cooling) High rpm 10 10 8 8 9 9 9 1,186 1,186 942 942 1,060 1,218 1,218 Low rpm 875 875 823 823 813 920 920 Speed (heating) High rpm 1,186 1,186 942 942 1,060 1,218 1,280 Low rpm 875 875 823 823 813 920 967 Motor Output (high) W 140 140 350 350 350 350 350 Drive Cooling Heating Direct drive Sound Power High dBA 63 63 57 57 61 66 66 Sound Pressure High dBA 37 37 37 37 38 40 40 Low dBA 29 29 29 29 32 33 33 High dBA 37 37 37 37 38 40 41 Low dBA 29 29 29 29 32 33 34 9.52 9.52 9.52 15.9 15.9 15.9 625 625 625 Sound Pressure Refrigerant Type Piping connections Liquid (OD) Type Gas Type R-410A Diameter (OD) Drain Flare connection mm 6.35 6.35 6.35 9.52 Flare connection Diameter (OD) mm Diameter (OD) mm 9.52 12.7 12.7 15.9 VP25 (O.D. 32 / I.D. 25) Heat Insulation Drain-up Height 1 >350 Nr of Rows Fin Pitch 3 2 Width Required Ceiling Void Heat Exchanger FBQ60C7VEB kW Unit Weight FBQ50C7VEB Cooling 2-2 Technical Specifications Casing FBQ35C7VEB Both liquid and gas pipes mm 625 • Split Sky Air • Indoor Units 625 625 625 3 • Indoor Units • R-410A • FBQ-C7VEB 2 Specifications 2-2 Technical Specifications FBQ35C7VEB FBQ50C7VEB FBQ60C7VEB FBQ71C7VEB Decoration Panel BYBS45DJW1 BYBS45DJW1 BYBS71DJW1 BYBS71DJW1 BYBS125DJW1 BYBS125DJW1 BYBS125DJW1 Model Colour Dimensions 1 2 Weight FBQ100C7VEB FBQ125C7VEB FBQ140C7VEB White (10Y9/0,5) H mm 55 55 55 55 55 55 55 W mm 800 800 1,100 1,100 1,500 1,500 1,500 D mm 500 500 500 500 500 500 500 kg 3.5 3.5 4.5 4.5 6.5 6.5 6.5 Air Filter Resin net with mold resistance Safety Devices PC board fuse PC board fuse (fan driver) Drain pump fuse Notes Nominal cooling capacities are based on : indoor temperature : 27°CDB, 19°CWB, outdoor temperature : 35°CDB, equivalent refrigerant piping : 7.5m, level difference : 0m. Nominal heating capacities are based on : indoor temperature : 20°CDB, outdoor temperature : 7°CDB, 6°CWB, equivalent refrigerant piping : 7.5m, level difference : 0m Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. The sound pressure values are mentioned for a unit installed with rear suction Remote Control 4 Wired BRC1D528 • Split Sky Air • Indoor Units • Indoor Units • R-410A • FBQ-C7VEB 3 Safety device settings Safety devices PC Board Fuse FBQ PC Board Fuse (Fan Driver) 35 50 60 71 100 125 140 250V 3.15A 250V 3.15A 250V 3.15A 250V 3.15A 250V 3.15A 250V 3.15A 250V 3.15A 250V 6.3A 250V 5A 250V 5A 250V 6.3A 250V 6.3A 250V 6.3A 250V 6.3A Fan Motor Thermal Protector °C — — — — — — — Drain Pump Fuse °C 145 145 145 145 145 145 145 3 1 3 4 Options FBQ35-140C Options Item Panel related Air inlet and air discharge outlet related Type FBQ35 Decoration panel Air discharge adapter for round duct FBQ50 BYBS45D KDAJ25K56A FBQ60,71 BYBS71D KDAJ25KA71A FBQ100,125,140 BYBS125D KDAJ25KA140A FBQ60,71 FBQ100,125,140 Operation Control Item Remote Control Wired Type Option BCB for external el. heater, humidifier and/or hour meter (*1), (*3) Adapter for wiring (interlock for fresh air intake fan) (*3) Wiring adapter for electrical appendices (*3) Central remote control Unified ON/OFF control Schedule timer Interface adapter for sky air series Remote ON/OFF and FORCED OFF kit Mounting plate for adapter PCB Type FBQ35 FBQ50 BRC1D528 EKRP1B2A KRP1BA54 KRP4A51 DCS302CA51 DCS301BA51 DST301BA51 DTA112BA51 EKRORO3 KRP4A96 NOTES (*1): Electrical heater and humidifier are field supply. These parts should not be installed inside the equipment (refer to installation manual EKRP1B2A) (*2): If installing an electrical heater, an option PCB for external heater (EKRP1B2) for each indoor unit is required. (*3): Mounting plate KRP4A96 is required for these options. Maximum 2 option PCB’s can be mounted. Contents of accessory bag Description Hexagon tapping screw (M5x16) Round plain washer for wood Installation and operation manual Hose band Insulation for joint (GAS) Insulation for joint (LIQUID) Drain hose Drain hose sealing material Sealing material Quantity FBQ35,50,60,71,100,125,140 16 8 1 1 1 1 1 1 2 3TW31279-3A • Split Sky Air • Indoor Units 5 • Indoor Units • R-410A • FBQ-C7VEB 4 Options EKRORO3 4 On Terminal X2M Screw to control box replacing the original terminal INPUT 1 Operating method Wire specifications Connector (White) T1,T2Switch Off Remote controller On Off unit connect to indoor PCB (X30A) Standard On setting: ’forced off’ Off Alternative setting: ’on/off’ On Off Input ’ON’ = closed contact. Forced off On/off operation Input ’on’ stops operation + disables control Input ’off’ enables control Input off→on: starts operation, remote control is still enabled. Input on→off: stops operation, remote control is still enabled. Selection of ’FORCED OFF’ and ’ON/OFF’ operation Setting Mode No. First code NO Forced off On/off operation 12 (22) 1 Second code NO 01 02 3TW31601-1 6 • Split Sky Air • Indoor Units • Indoor Units • R-410A • FBQ-C7VEB 5 Dimensional drawing & centre of gravity 5-1 Dimensional drawing 3 FBQ35C NOTES 1 2 View A-A 3 Detail B Refer to ‘outlook drawing for installing optional accessories’ when installing optional accessories. The required ceiling depth varies according to the configuration of the specific system. For maintenance of the air filter, it is necessary to provide a service access panel. Refer to the ‘filter installation method’ drawing 1 5 or more (service space) suspension bolt or more (service space) Detail B (suspension position) (suspension position) Item 1 2 3 4 5 6 7 8 9 10 Name Liquid pipe connection Gas pipe connection Drain pipe connection Remote control wiring connection Power supply connection Drain hole Air filter Air suction side Air discharge side Nameplate Description Ø6.35 flare connection Ø9.52 flare connection VP25 (OD Ø32, ID Ø25) VP25 (OD Ø32, ID Ø25) - 3TW31274-1 FBQ50C Detail B View A-A 350 or more (Service space) Suspension bolt or more (Service space) Detail B (Suspension position) (Suspension position) Nr Name Description 1 2 3 4 5 6 7 8 9 10 Liquid pipe connection Gas pipe connection Drain pipe connection Remote control wiring connection Power supply connection Drain hole Air filter Air suction side Air discharge side Nameplate ø 6.35 flare (connection) ø 12.70 (flare connection) VP25 (O.D. ø 32 /I.D. ø 25) NOTE 1 2 VP25 (OD ø 32 /I.D. ø 25) 3 Refer to ‘outlook drawing for installing optional accessories’ when installing optional accessories. The required ceiling depth varies according to the configuration of the specific system. For maintenance of the air filter, it is necessary to provide a service access panel. Refer to the ‘filter installation method’ drawing. 3TW31214-1 • Split Sky Air • Indoor Units 7 • Indoor Units • R-410A • FBQ-C7VEB 5 Dimensional drawing & centre of gravity 5-1 Dimensional drawing FBQ60C 1 5 View A-A Detail B 350 or more (Service space) Suspension bolt Detail B or more (Service space) (Suspension position) (Suspension position) Nr 1 2 3 4 5 6 7 8 9 10 Name Liquid pipe connection Gas pipe connection Drain pipe connection Remote control wiring connection Power supply connection Drain hole Air filter Air suction side Air discharge side Nameplate NOTE Description ø 6.35 flare (connection) ø 12.70 (flare connection) VP25 (O.D. ø 32 /I.D. ø 25) 1 VP25 (OD ø 32 /I.D. ø 25) 3 2 Refer to ‘outlook drawing for installing optional accessories’ when installing optional accessories. The required ceiling depth varies according to the configuration of the specific system. For maintenance of the air filter, it is necessary to provide a service access panel. Refer to the ‘filter installation method’ drawing. 3TW31294-1 FBQ71C View A-A Detail B 350 or more (Service space) Suspension bolt Detail B or more (Service space) (Suspension position) (Suspension position) Nr 1 2 3 4 5 6 7 8 9 10 Name Liquid pipe connection Gas pipe connection Drain pipe connection Remote control wiring connection Power supply connection Drain hole Air filter Air suction side Air discharge side Nameplate NOTE Description ø 9.52 flare (connection) ø 15.90 (flare connection) VP25 (O.D. ø 32 /I.D. ø 25) 1 VP25 (OD ø 32 /I.D. ø 25) 3 2 Refer to ‘outlook drawing for installing optional accessories’ when installing optional accessories. The required ceiling depth varies according to the configuration of the specific system. For maintenance of the air filter, it is necessary to provide a service access panel. Refer to the ‘filter installation method’ drawing. 3TW31234-1 8 • Split Sky Air • Indoor Units • Indoor Units • R-410A • FBQ-C7VEB 5 Dimensional drawing & centre of gravity 5-1 Dimensional drawing 3 FBQ100-140C 1 5 View A-A Detail B 350 or more (Service space) Suspension bolt Detail B or more (Service space) (Suspension position) (Suspension position) Nr Name Description 1 2 3 4 5 6 7 8 9 10 Liquid pipe connection Gas pipe connection Drain pipe connection Remote control wiring connection Power supply connection Drain hole Air filter Air suction side Air discharge side Nameplate ø 9.52 flare (connection) ø 15.90 (flare connection) VP25 (O.D. ø 32 /I.D. ø 25) NOTE 1 2 VP25 (OD ø 32 /I.D. ø 25) 3 Refer to ‘outlook drawing for installing optional accessories’ when installing optional accessories. The required ceiling depth varies according to the configuration of the specific system. For maintenance of the air filter, it is necessary to provide a service access panel. Refer to the ‘filter installation method’ drawing. 3TW31254-1 • Split Sky Air • Indoor Units 9 • Indoor Units • R-410A • FBQ-C7VEB 5 Dimensional drawing & centre of gravity 5-2 Centre of gravity FBQ35-140C 1 5 MODEL FBQ35,50 FBQ60,71 FBQ100~140 A 283 441 619 B 700 1000 1400 4TW31189-1A 10 • Split Sky Air • Indoor Units • Indoor Units • R-410A • FBQ-C7VEB 6 Piping diagram 3 FBQ35-140C Heat exchanger 1 Refrigerant flow Cooling Heating 6 Refrigerant pipe connection port diameters Model FBQ35C FBQ50C FBQ60C FBQ71C FBQ100C FBQ125C FBQ140C Gas 9.52 12.70 12.70 15.90 15.90 15.90 15.90 Liquid 6.35 6.35 6.35 9.52 9.52 9.52 9.52 Liquid pipe connection port Gas pipe connection port 3TW31275-1 • Split Sky Air • Indoor Units 11 • Indoor Units • R-410A • FBQ-C7VEB 7 Wiring diagram 7-1 Wiring diagram FBQ35-50C7VEB L N indoor 1 , : Connector : Wire clamp : Protective earth (screw) norm.emg 7 Transmission wiring central remote control note 2 1N~220-240V 50Hz 1N~220V 60Hz Colors BLK BLU BRN GRY ORG PNK RED WHT YLW GRN wired remote control (optional accessory) Common power supply note 4 Switch box (indoor) Indoor unit A1P A2P C1 F1U, F2U F4U HAP KPR, K1R L1R Printed circuit board Printed circuit board (fan) Capacitor Fuse (T, 5A, 250V) Fuse (T, 6.3A, 250V) Light emitting diode (Service monitor green) Magnetic relay Reactor M1F M1P PS Q1DI R1 R2 R1T R2T R3T Motor (fan) Motor (drain pump) Switching power supply Earth leak detector Resistor (current limiting) Current sensing device Thermistor (suction air) Thermistor (liquid) Thermistor (gas) SS1 S1L V1R V2R X1M X2M Z1C Z1F RC Selector switch (emergency) Float switch Diode bridge Power module Terminal strip (power supply) Terminal strip (control) Noise filter (ferrite core) Noise filter Signal receiver circuit TC : Field wiring : Live : Neutral : Black : Blue : Brown : Gray : Orange : Pink : Red : White : Yellow : Green Signal transmission circuit Connector optional accessory X28A X33A X35A X85A X33A Connector (Power supply for wiring) Connector (for wiring) Connector (adapter) Connector (for multi zoning) Connector (for wiring) SS1 Selector switch (emergency) Wired remote control 2TW31276-1A NOTES 1 2 3 4 Use copper conductors only. When using the central remote controller, see manual for connection to the unit. The remote control model varies according to the combination system. See technical materials and catalogues, etc. before connecting. Refer to installation manual. FBQ60-140C7VEB only for 60 class only for 60 class L N , : Connector : Wire clamp : Protective earth (screw) NORM. EMG Transmission wiring central remote control note 2 1N~220-240V 50Hz 1N~220V 60Hz Wired remote control (optional accessory) Common power supply note 4 : Field wiring : Live : Neutral Colors BLK BLU BRN GRY ORG PNK RED WHT YLW GRN : Black : Blue : Brown : Gray : Orange : Pink : Red : White : Yellow : Green Switch box (indoor) A1P A2P A3P C1, C2, C3 F1U F3U HAP KPR, K1R Indoor unit Printed circuit board Printed circuit board (fan) Printed circuit board (capacitor) Capacitor Fuse (T, 5A, 250V) Fuse (T, 6.3A, 250V) Light emitting diode (service monitor green) Magnetic relay L1R M1F M1P PS Q1DI R2 R3, R4 R1T R2T Reactor Motor (fan) Motor (drain pump) Switching power supply Earth leak detector Current sensing device Resistor (electric discharge) Thermistor (suction air) Thermistor (liquid) R3T R5T SS1 S1L V1R V2R Z1C Z1F RC Thermistor (gas) Thermistor NTC (Current limiting) Selector switch (emergency) Float switch Diode bridge Power module Noise filter (ferrite core) Noise filter Terminal strip (power supply) TC Y1E X33A X35A X38A R1T SS1 Terminal strip (control) Electronic expansion valve Connector optional accessory Connector (for wiring) Connector (adapter) Connector (for wiring) Wired remote control Thermistor (air) Selector switch (main/sub) 2TW31296-1A NOTES 1 2 3 4 12 Use copper conductors only. When using the central remote controller, see manual for connection to the unit. The remote control model varies according to the combination system. See technical materials and catalogues, etc. before connecting. Refer to installation manual. • Split Sky Air • Indoor Units • Indoor Units • R-410A • FBQ-C7VEB 8 Sound data 8-1 Sound pressure spectrum FBQ35-50C 3 FBQ60C 8 Sound pressure level [dB] Sound pressure level [dB] 1 Octave band center frequency (Hz) Octave band center frequency (Hz) High-tap High-tap Medium-tap Medium-tap Low-tap Low-tap 3TW31217-2 3TW31297-2 NOTES 1 2 3 4 5 NOTES Data is valid at free field condition Data is valid at nominal operation condition dBA= A-weighted sound pressure level. (A-scale according to IEC) Reference acoustic pressures 0dB = 20μPa Location of microphone Unit Suction 1 2 3 4 5 Discharge Data is valid at free field condition Data is valid at nominal operation condition dBA= A-weighted sound pressure level. (A-scale according to IEC) Reference acoustic pressures 0dB = 20μPa Location of microphone Unit Suction Microphone Discharge Microphone Sound pressure level [dB] FBQ100C Sound pressure level [dB] FBQ71C Octave band center frequency [dB] Octave band center frequency [dB] High-tap Medium-tap Low-tap High-tap Medium-tap Low-tap 3TW31297-2 3TW31257-2 Notes Data is valid at free field condition Data is valid at nominal operation condition dBA = A-weighted sound power level. (A-scale according to IEC) Reference acoustic pressures 0dB = 20μPa Location of microphine 1.5m Suction Unit 2m 1.5m 2m Discharge Microphone 1m 1 2 3 4 5 Data is valid at free field condition Data is valid at nominal operation condition dBA = A-weighted sound power level. (A-scale according to IEC) Reference acoustic pressures 0dB = 20μPa Location of microphine Suction 1.5m Notes 1 2 3 4 5 Unit 2m 1.5m 2m Discharge Microphone 1m • Split Sky Air • Indoor Units 13 • Indoor Units • R-410A • FBQ-C7VEB 8 Sound data 8-1 Sound pressure spectrum FBQ125C FBQ140C Sound pressure level [dB] 8 Sound pressure level [dB] 1 Octave band center frequency [dB] Octave band center frequency [dB] High-tap Medium-tap Low-tap High-tap Medium-tap Low-tap 3TW31267-2 3TW31337-2 Notes Data is valid at free field condition Data is valid at nominal operation condition dBA = A-weighted sound power level. (A-scale according to IEC) Reference acoustic pressures 0dB = 20μPa Location of microphine 1.5m Suction Unit 2m 1.5m 2m Discharge Microphone 1m 14 1 2 3 4 5 Data is valid at free field condition Data is valid at nominal operation condition dBA = A-weighted sound power level. (A-scale according to IEC) Reference acoustic pressures 0dB = 20μPa Location of microphine Suction 1.5m Notes 1 2 3 4 5 Unit 2m 1.5m Discharge Microphone 1m • Split Sky Air • Indoor Units 2m • Indoor Units • R-410A • FBQ-C7VEB 8 Sound data 8-2 Sound power spectrum FBQ35-50C 3 FBQ60C 8 Sound power level [dB] Sound power level [dB] 1 Octave band center frequency (Hz) Octave band center frequency (Hz) High-tap High-tap Medium-tap Medium-tap Low-tap Low-tap 3TW31217-1 3TW31297-1 NOTES 1 2 3 NOTES dBA= A-weighted sound power level. (A-scale according to IEC) Reference acoustic intensity 0dB = 10E-6μW/m2 Measured according to ISO 3744 1 2 3 Sound pressure level [dB] FBQ100C Sound pressure level [dB] FBQ71C dBA= A-weighted sound power level. (A-scale according to IEC) Reference acoustic intensity 0dB = 10E-6μW/m2 Measured according to ISO 3744 Octave band center frequency [dB] Octave band center frequency [dB] High-tap Medium-tap Low-tap High-tap Medium-tap Low-tap 3TW31297-1 3TW31257-1 Notes 1 2 3 Notes dBA = A-weighted sound power level. (A-scale according to IEC) Reference acoustic intensity 0dB = 10E-6μW/m2 Measured according to ISO 3744 • Split Sky Air • Indoor Units 1 2 3 dBA = A-weighted sound power level. (A-scale according to IEC) Reference acoustic intensity 0dB = 10E-6μW/m2 Measured according to ISO 3744 15 • Indoor Units • R-410A • FBQ-C7VEB 8 Sound data 8-2 Sound power spectrum FBQ125-140C 8 Sound pressure level [dB] 1 Octave band center frequency [dB] High-tap Medium-tap Low-tap 3TW31267-1 Notes 1 2 3 16 dBA = A-weighted sound power level. (A-scale according to IEC) Reference acoustic intensity 0dB = 10E-6μW/m2 Measured according to ISO 3744 • Split Sky Air • Indoor Units • Indoor Units • R-410A • FBQ-C7VEB 9 Fan characteristics 3 FBQ35-50C Fan characteristics (3) (airflow auto adjustment) 1 H (max ESP) Upper limint of ESP (max ESP ) External static pressure [Pa] External static pressure [Pa] Fan characteristics (1) Lower limit of ESP (max ESP) M (max ESP) L (max ESP) Upper limint of ESP (std ESP ) H (std ESP) M (std ESP) 9 Upper limint of ESP Upper limint of ESP by airflow auto adjustment H M Upper limint of ESP by airflow auto adjustment L Lower limit of ESP (std ESP) L (std ESP) Lower limit of ESP Airflow [m3/min] Airflow [m3/min] Fan characteristics (2) (Field setting with remote control) External static pressure [Pa] Range of available air flow rate (H) NOTES 1 2 Airflow [m3/min] Fan characteristics as shown are in “fan only” mode. ESP: External static pressure 3TW31218-1 FBQ60C Fan characteristics (3) (airflow auto adjustment) Upper limint of ESP (max ESP ) External static pressure [Pa] External static pressure [Pa] Fan characteristics (1) H (max ESP) M (max ESP) L (max ESP) Lower limit of ESP (max ESP) Upper limint of ESP (std ESP ) H (std ESP) M (std ESP) L (std ESP) Upper limint of ESP Upper limint of ESP by airflow auto adjustment H M L Upper limint of ESP by airflow auto adjustment Lower limit of ESP (std ESP) Lower limit of ESP Airflow [m3/min] Airflow [m3/min] Fan characteristics (2) (Field setting with remote control) External static pressure [Pa] Range of available air flow rate (H) NOTES 3/min] Airflow [m 1 2 Fan characteristics as shown are in “fan only” mode. ESP: External static pressure 3TW31298-1 • Split Sky Air • Indoor Units 17 • Indoor Units • R-410A • FBQ-C7VEB 9 Fan characteristics FBQ71C 9 Fan characteristics (3) (Airflow auto adjustment) External static pressure [Pa] 1 External static pressure [Pa] Fan characteristics (1) H (max. ESP) Upper limit of ESP (max. ESP) M (max. ESP) Lower limit of ESP (max. ESP) L (max. ESP) Upper limit of ESP (std. ESP) H (std ESP) M (std ESP) L (std ESP) Upper limit of ESP Upper limit of ESP by airflow auto adjustment H M L Lower limit of ESP by airflow auto adjustment Lower limit of ESP (std. ESP) Lower limit of ESP Airflow [m³/min] Airflow [m³/min] Fan characteristics (2) (Field setting with remote control) External static pressure [Pa] Range of available air flow rate (H) NOTES 1 2 Airflow [m³/min] Fan characteristics as shown ar in “fan only” mode. ESP: External static pressure 3TW31298-1 FBQ100C Fan characteristics (1) Fan characteristics (3) (Airflow auto adjustment) Lower limit of ESP (max. ESP) M (max. ESP) L (max. ESP) Upper limit of ESP (std. ESP) L (std ESP) H (std ESP) M (std ESP) Upper limit of ESP by airflow auto adjustment Upper limit of ESP External static pressure [Pa] External static pressure [Pa] H (max. ESP) Upper limit of ESP (max. ESP) H M L Lower limit of ESP by airflow auto adjustment Lower limit of ESP Lower limit of ESP (std. ESP) Airflow [m³/min] Airflow [m³/min] Fan characteristics (2) (Field setting with remote control) External static pressure [Pa] Range of available air flow rate (H) NOTES 1 2 Fan characteristics as shown ar in “fan only” mode. ESP: External static pressure Airflow [m³/min] 3TW31258-1 18 • Split Sky Air • Indoor Units • Indoor Units • R-410A • FBQ-C7VEB 9 Fan characteristics 3 FBQ125C Fan characteristics (1) Fan characteristics (3) (Airflow auto adjustment) 1 Upper limit of ESP External static pressure [Pa] External static pressure [Pa] H (max. ESP) Upper limit of ESP (max. ESP) M (max. ESP) Lower limit of ESP (max. ESP) L (max. ESP) H (std ESP) Upper limit of ESP (std. ESP) M (std ESP) Lower limit of ESP (std. ESP) L (std ESP) 9 Upper limit of ESP by airflow auto adjustment H M L Lower limit of ESP by airflow auto adjustment Lower limit of ESP Airflow [m³/min] Airflow [m³/min] Fan characteristics (2) (Field setting with remote control) External static pressure [Pa] Range of available air flow rate (H) NOTES 1 2 Airflow [m³/min] Fan characteristics as shown ar in “fan only” mode. ESP: External static pressure 3TW31268-1 FBQ140C Fan characteristics (3) (airflow auto adjustment) H (max ESP) Upper limint of ESP (max ESP ) External static pressure [Pa] External static pressure [Pa] Fan characteristics (1) Lower limit of ESP (max ESP) M (max ESP) H (std ESP) Upper limint of ESP L (max ESP) (std ESP ) Lower limit of ESP (std ESP) M (std ESP) Upper limint of ESP Upper limint of ESP by airflow auto adjustment H M L Upper limint of ESP by airflow auto adjustment Lower limit of ESP L (std ESP) Airflow [m3/min] Airflow [m3/min] Fan characteristics (2) (Field setting with remote control) External static pressure [Pa] Range of available air flow rate (H) NOTES Airflow [m3/min] 1 2 Fan characteristics as shown are in “fan only” mode. ESP: External static pressure 3TW31268-1 • Split Sky Air • Indoor Units 19 • Indoor Units • R-410A • FBQ-C7VEB 10 Installation 10 - 1 Installation method FBQ35-140C 1 Rear Suction Bottom Suction Ceiling return Ceiling return 10 Drain pump up height Direct installation of inlet panel Installation with duct Wide variety of installation methods Number 1 2 3 4 5 Description Main body Air outlet duct Inlet panel Acces panel Air inlet duct Field supply Optional accessory optional accessory Field supply Easy modification from rear to bottom suction 3TW31183-1 20 • Split Sky Air • Indoor Units • Indoor Units • R-410A • FBQ-C7VEB 10 Installation 10 - 2 Filter installation method 3 FBQ35-140C (or less) 1 10 Installation without air inlet duct Installation with air inlet duct NOTES Nr. 1 2 3 4 5 6 Description Suspended Ceiling Ceiling opening Service access panel (optimal) Air filter Air inlet duct Duct service opening 1 2 When installing the unit with rear suction, a service opening is necessary for the maintenance of the air filters. When installing the unit with a suction duct. A service opening must be provided in the duct. 3TW31184-4 • Split Sky Air • Indoor Units 21 • Indoor Units • R-410A • FBQ-C7VEB 10 Installation 10 - 3 Switch box connection FBQ35-140C 1 10 Emerg. Norm. Common power supply 3TW31184-5 22 • Split Sky Air • Indoor Units Daikin Europe N.V. is approved by LRQA for its Quality Management System in accordance with the ISO9001 standard. ISO9001 pertains to quality assurance regarding design, development, manufacturing as well as to services related to the product. ISO14001 assures an effective environmental management system in order to help protect human health and the environment from the potential impact of our activities, products and services and to assist in maintaining and improving the quality of the environment. Daikin units comply with the European regulations that guarantee the safety of the product. Naamloze Vennootschap Zandvoordestraat 300 B-8400 Oostende, Belgium www.daikin.eu BTW: BE 0412 120 336 RPR Oostende Daikin Europe N.V. is participating in the EUROVENT Certification Programme. Products are as listed in the EUROVENT Directory of Certified Products. The present publication is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V. has compiled the content of this publication to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from or related to the use and/or interpretation of this publication. All content is copyrighted by Daikin Europe N.V.. Prepared in Belgium by Lannoo (www.lannooprint.be), a company whose concern for the environmont is set in the EMAS and ISO 14001 systems. Responsible Editor: Daikin Europe N.V., Zandvoordestraat 300, B- 8400 Oostende Daikin’s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants has led to its close involvement in environmental issues. For several years Daikin has had the intension to become a leader in the provision of products that have limited impact on the environment. This challenge demands the eco design and development of a wide range of products and an energy management system, resulting in energy conservation and a reduction of waste.