Fc 79 - Control Interface Slave

   EMBED


Share

Transcript

Control Interface Slave Function Code 79 (7 9 ) N N+1 N+2 N+3 N+4 S10 Use the control interface slave function code to interface a Harmony controller to a control I/O module. Control I/O modules have four analog inputs, two analog outputs, three digital inputs, and four digital outputs. This function code defines the characteristics of that I/O module and how the system responds to an I/O module failure. N+5 S11 Outputs C IS I/O N+6 N+7 N+8 S15 Blk Type N R Analog input 1 S16 N+1 R Analog input 2 S17 S18 N+2 R Analog input 3 N+3 R Analog input 4 N+4 R Analog output 1 feedback N+5 R Analog output 2 feedback N+6 B Digital input 1 N+7 B Digital input 2 N+8 B Digital input 3 N+9 B I/O module status flag: 0 = good, 1 = bad N+9 Description The control system must be carefully evaluated to establish default values that will prevent personal injury and/or property damage in the case of module failure. WARNING Specifications Spec Tune Default Type Range S1 N 0 I 0 - 63 S2 N 0.000 R Full Analog input 1 zero in engineering units S3 N 0.000 R Full Analog input 1 span in engineering units S4 N 0.000 R Full Analog input 2 zero in engineering units S5 N 0.000 R Full Analog input 2 span in engineering units S6 N 0.000 R Full Analog input 3 zero in engineering units S7 N 0.000 R Full Analog input 3 span in engineering units WBPEEUI210504B0 Description Control interface I/O module address 79 - 1 Specifications (continued) Spec Tune Default Type Range S8 N 0.000 R Full Analog input 4 zero in engineering units Description S9 N 0.000 R Full Analog input 4 span in engineering units S10 N 2 I 0 - 2046 Block address of analog output 1 S11 N 2 I 0 - 2046 Block address of analog output 2 S12 N 2 I 0 or 1 Digital input 1 logic sense S13 N 2 I 0 or 1 Digital input 2 logic sense S14 N 2 I 0 or 1 Digital input 3 logic sense S15 N 2 I 0 - 2046 Block address of digital output 1 S16 N 2 I 0 - 2046 Block address of digital output 2 S17 N 2 I 0 - 2046 Block address of digital output 3 S18 N 2 I 0 - 2046 Block address of digital output 4 S19 N 0 I 0 or 1 Failure action (lack of I/O module response or bad analog input reference voltage): XX0 = trip module XX1 = continue to operate I/O module status flag (bad status indication): 0XX = set I/O module status flag output N+9 to bad when the CIS module fails or is in error mode 1XX = set I/O module status flag output N+9 to bad when the I/O module fails or there is a bad quality on one of the module's I/O points Explanation Outputs This block provides analog and digital I/O on the same board. The final output is an I/O module status flag, which shows the status of the control I/O module. 0 = good 1 = bad Analog output feedbacks (N+4 and N+5) provide feedback to M/A stations (function code 80) that have hardware stations with bypass capabilities. This feedback signal provides an alignment reference for the software logic, before establishing 79 - 2 WBPEEUI210504B0 control of the process when exiting from bypass or configure mode (bumpless transfer). NOTE: If S19 equals zero, and if there is a bad or unwired input, then the control module is tripped. Specifications S1 – IOSLV (Control I/O module address) I/O module address set by the address dipswitch on the I/O module. Available addresses are zero through 63. S2 to S9 (AIZn and AISPn) Set the zero and span values for four analog inputs. If an analog value goes below the zero value or exceeds the span by more than five percent, it will produce a bad quality output. A specified span other than zero (default) for an unused analog input produces a bad quality signal for that input. S10 – AO1 Block address of input for analog output one. S11 – AO2 Block address of input for analog output two. S12 to S14 - DIn Set the logic sense for three digital inputs. Digital inputs can be defined for direct or reverse acting logic operations. These are defined as follows: 0 = reverse acting (logic 0 = closed, logic 1 = open) 1 = direct acting (logic 0 = open, logic 1 = closed) 2 = unused input S15 to S18 - DOn S19 – FAIL WBPEEUI210504B0 Block addresses of the inputs for the four digital outputs. Value defines the module response in case of control I/O module failure. Lack of I/O module response or a bad analog input reference voltage will cause a transfer to error mode. 79 - 3 Specification S19 also determines which failure conditions cause the I/O module status flag output N+9 to go to logic 1 (bad). X X X Failure Action 0 = trip control module 1 = continue operation Reserved for Future Use I/O Module Status Flag 0 = selects the I/O module status flag output N+9 to equal logic 1 (bad quality) when the I/O module is failed or in error mode. 1 = selects the I/O module status flag output N+9 to equal logic 1 (bad quality) when the control I/O module is in error mode or a defined I/O point (AI, AO, DI or DO) is bad quality. 79 - 4 WBPEEUI210504B0