Transcript
NICD RECHARGEABLE CYLINDRICAL BATTERY SPECIFICATIONS Model Description Nominal Capacity Nominal Voltage Cut-Off Voltage End of Charge Voltage Approx. Weight Internal Impedance Life Duration Charge
: : : : : : : : : :
Temperature Environment
:
Permanent Charge Charge Retention Leakage Vibration Test (for cell)
: : : :
Shock Test (for cell)
:
N1500SC(HT) NiCd rechargeable battery, 'SC' size, flat cap, high temperature 1500 mAh at 300mA rate discharge(3 cycles allowed) 1.2 Volt (After charge) 1.0 Volt <= 1.6 Volt 45 gram <= 14mOhm per cell (1KHz AC test upon full charge) >= 50 cycles (Comply to IEC 61951-1 Ed. 2.1 2006) Trickle - 45-75 mA Standard - 150 mA x 14-16 hours Standard and Trickle charge - 0 degC to 70 degC Discharge - -20 degC to 70 degC Storage - -20 degC to 30 degC Comply to IEC 61951-1 Ed. 2.1 2006, Section 7.4.2.3 >60% for 28 days storage after standard charge No leakage, No explosion under standard operating condition Battery remain normal after vibration at Amp: 4mm; Freq.: 1000/min for 60 min. Battery remain normal after dropping from 450mm to an Oak board for 3 times
22.2+/-0.2mm
Battery : N1500SC(HT) Charge : 75mA (0.05C)x48hrs
1.8 1.7 1.6 1.5 1.4 1.3 1.2 1.1 1.0
0C o 20 C 55 oC 70 oC o
0
6
12
18 24 30 36 Charge Time (hours)
42
48
54
42+/-0.5mm
Voltage (V)
Typical Standard Charge Characteristics (Cylindrical Cell)
Voltage (V)
Typical Discharge Characteristics (Cylindrical Cell) 1.6 1.5 1.4 1.3 1.2 1.1 1.0 0.9 0.8
Battery : N1500SC(HT) Charge : 75mA (0.05C)x48hrs Discharge : 300mA (0.2C) to 1.0V
70 oC
0
20
40
0 oC 55 oC
22.2+/-0.2mm
20 oC
60 80 100 120 Discharge Capacity (%)
140
PVC Jacket Typical Discharge Capacity
110 100 90 80 70 60 50 40 30
Capacity (%)
Remaining Capacity (%)
Typical Charge Retention Characteristics (Cylindrical Cell)
Battery : N1500SC(HT) Charge : 150mA (0.1C)x15hrs Discharge : 300mA (0.2C) to 1.0V 0
1
2 Storage Time (weeks)
3
4
140 120 100 80 60 40 20 0
Battery : N1500SC(HT) Charge : 75mA (0.05C)x48hrs Discharge : 300mA (0.2C) to 1.0V
-10
0
10
20 30 40 50 60 Temperature (degreeC)
70
Information is for references only. Performance varies with time, usage and storage condition. 1 year limited guarantee against manufacturing defects. Other problem caused by misuse, mishandling of cell, or malfunction of equipment, is not under the warranty.
Model : N1500SC(HT) Version : 2.80
WELL LINK
INDUSTRIAL LIMITED
FC03K03