Preview only show first 10 pages with watermark. For full document please download

Fcs Medical Control - Laboratorios Macrimasa

   EMBED


Share

Transcript

VITALFIC® E30 3-channel Electrocardiograph FCS MEDICAL CONTROL®       High resolution LCD screen, vivid wave form display Resolution: 320x240. Built-in rechargeable Li-ion battery, AC/DC power supply. Complete digital filtering, resisting baseline drift. Automatic baseline adjustment. Large patient data storage: 150 ECGs, USB for data transfer to PC. 1/2/3 channel ECG waveform and rhythm leads record out.       12 leads ECG simultaneous acquisition. Built-in high-resolution thermal printer. Anti-defibrillation and Pace-maker detection. Automatic ECG measurement and interpretation. Three printing formats (Auto, Manual and Rhythm) selectable. Lead status diagram display. E30 Electrocardiograph three-channel Compact, light weight and protable design. Simple interface display, easy opeation mode Automatic measurement report ECG lead status diagram map Technical Specifications VITALFIC® E30 Electrocardiograph three-channel ECG FCS MEDICAL CONTROL® Technical Specification VITALFIC® E30 Input Circuit Lead Acquisition Mode A/D converter Measurement range Time Constant Frequency Response Calibration voltage Sensitivity Input Impedance Input Circuit Current: Noise Level: Anti Baseline Drift Filter CMRR: Recording Mode: Rhythm Lead Power Supply Recorder Paper Style Record Pater Paper Speed Dimension Weight Display External input External output Communication Interface Defibrillation Production Built-in Standard 12 leads 12 lead ECG simultaneously 12bits ±5m Vpp ≥3.2s 0.05Hz-150Hz 1mV ± 2% 2.5mm/mV, 5mm/mV, 10mm/mV, 20mm/mV. ≥ 50 MΩ < 0.05mA <15µ Vp-p Automatic AC Filter: 50 Hz/ 60 Hz/ Off EMC Filter: 25 Hz/ 35Hz/ 45 Hz/ Off Drift Filter: 0.05 Hz/ 0.1 Hz/ 0.2 Hz/ 0.5 Hz Lowerpass Filter: 70 Hz/ 100 Hz/ 150 Hz ≥100dB Auto: 3CH, 3CH+1R, 1CH, 1CH+1R Manual:3CH, 1CH Rhythm: Single rhythm lead Any lead selectable DC and acpower supply, (100-150V/220-240V, 50/60Hz) Built-in rechargeable li-ion battery voltage=14.4V, at least 2 hours working time. Thermal printer Rolled or folded 80mm x 20m 5mm/s, 10mm/s, 25mm/s, 50mm/s 32mmx28mmx65mm 3kg (with battery) 320x240 pixels LCD ≥100KΩ, Sensitivity 10mm/V ±5% ≤100Ω, Sensitivity 1V/V ±5% Ethernet (option) Laboratorios Macrimasa-Pharma, S.A. complies with directive 93/42/CEE concerning medical devices and quality standards ISO 9001 and ISO 13485. LABORATORIOS MACRIMASA-PHARMA, S.A. C/ Marie Curie 3Parque Tecnológico de Andalucía 29590 - Campanillas - Málaga - España Tel. : + 34 - 902 366 106 Fax. : +34 - 902 366 108 [email protected] www.macrimasa.com LMP24/03/2014(E) 0086