Transcript
Titebond 991 PROvantage ®
ADVANCED SOLVENT FLOORING ADHESIVE
e g a t n a v O PR
991
k Street 2020 Bruc Ohio 43207 Columbus, 41 614-443-02
E G A T N A 991 PROV
onstruction c w e n in e s u r • Fo y lvent technolog • Advanced so ength • Superior str en grab • Excellent gre ily • Spreads eas nt • VOC-complia
T - VOC SOLVEN D E C N A ADV
ANT COMPLI
RING O O L F WOOD ESIVE ADH AD VA NC
EN T ED SO LV
VO C
AD HE SI VE
S
TM
NT CO M PL IA
uctivity, roved prod p im d n a , as ons d flooring k installati re ic e u e q in g g n e n with all ood Floori d flooring primarily solid woo vantage W d C n O a V ® 991 PRO o o Ovantage etary amb Titebond d 991 PR on propri well as b n o b d is e e h s it a T T b . y. k ic is p. The log to 5/8” th Adhesive y to cleanu ent techno s p lv a u o e s is h d it e d c n w n a ly ller and is adva els smooth es the insta resistant, compliant w id o v re tr ro tu p is r o n o o ri m pe binati highly to moisture rab and su unique com adhesive is y exposure ent green g y b ll ll e d ta c te x n c e e e f m ff o n a iro is proudly ely the benefits being env not advers ROvantage e P l il h 1 ra 9 w e 9 d , e d F th n ng with all ter. Titebo bond stre . complying for or wa l d a n e a id in the USA le is ib s nufactured respon ons. It a ti m la u g to re lf e VOC it lends its and State uction, as tr s n o c w use in ne
ts ion Produc Construct 669-4583 0TEL 1-80 879-4553 0FAX 1-80
Division
Why Professional Installers Prefer Titebond 991 PROvantage ®
PROvantage = Performance Without Compromise Titebond 991 PROvantage is a proprietary, advanced solvent technology that provides superior performance while complying with all Federal and State VOC regulations as well as the South Coast Air Quality Management District. It offers key benefits of conventional solvent-based adhesives without compromising adhesion attributes. It is environmentally responsible and is 100% compliant for sale throughout the USA.
991 PROvantage FEATURES AND BENEFITS
• Specifically designed for use in new construction • Up to 65 sq. ft./gallon for engineered flooring
New Construction Installation For efficient installation and maximum productivity in new construction flooring installations, 991 PROvantage is an excellent choice. The adhesive sets up quickly and minimizes board movement. Once cured, it allows for natural movement of wood flooring during seasonal environment changes.
Excellent Green Grab In addition to a rapid cure rate, Titebond 991 PROvantage builds rapid initial strength as well. The adhesive establishes aggressive green strength, providing the installer with confidence that the wood flooring will not slide once seated into the wet adhesive.
• Superior strength • Solvent-based performance • Easy clean-up – Wet and cured adhesive can be easily removed from surface with mineral spirits • High moisture resistance
No Flash Time Required Once the adhesive has been troweled, the wood flooring should be installed immediately into the wet adhesive. This allows the installer to begin laying the floor immediately, resulting in a shorter installation time.
• Ideal for installation of all engineered flooring, as well as bamboo and solid flooring up to 5/8” thick
Trowels Easily
• VOC-compliant
Titebond 991 PROvantage is a unique and proprietary formula that gives the professional installer an adhesive that trowels easily and smoothly, especially when compared to other adhesive technologies.
Minimizes Hollow and Popping Spots Hollow spots, popping spots and squeaks are related to unevenness. Titebond 991 PROvantage reduces hollow and popping spots. The adhesive does a superior job of bridging normal gaps between the wood and the subfloor. Titebond 991 PROvantage will greatly reduce the professional installer’s chances of running into this costly problem.
Made in USA As with all Titebond branded flooring adhesives from Franklin International, 991 PROvantage is proudly made in the USA.
• Helps minimize hollow spots • Can be transported safely – Follow local, state and federal DOT regulations • Approved for use with Titebond 531 Moisture Control System • Made in USA
SPECIFICATION GUIDE FOR TITEBOND® 991 PROvantage Type of Flooring/Flooring Thickness
Jobsite /Subfloor
• All parquets measuring less than 3/4” thick
• New, old or existing concrete, properly treated light weight concrete
• All engineered flooring
• Below-grade concrete
• Solid wood flooring measuring 5/8” or less in thickness
• Plywood
• Bamboo flooring
• OSB (Oriented Strand Board)
• 3/4” solid shorts (less than 24”)
• Radiant heated slabs
• 5/8” plywood (2’x 8 ’ or 4’x 4 ’)
• Clean and unwaxed vinyl • Cork
2
991 PROvantage HELPFUL HINTS Limitations
• Do not install solid wood below-grade • Do not use on concrete with curing agents or sealers (except for recommended Titebond or Franklin products) • Do not allow foot traffic for 8 hours after installation • Do not use as a subfloor leveler • Installations in dry or cool environments or over dry subfloors will take longer to cure • Temperature and humidity will affect the open time and cure time of the adhesive • Open time is 30-45 minutes depending on temperature and humidity
Storage/Shelf Life • Store in a clean, dry environment above 60˚F • Shelf life is 1 year from date of manufacture
Re-sealing Partial Pail 1. Scrape sides of pail (this will aid in removal of adhesive later) 2. Replace lid on pail and tightly seal
Gluing a Plywood Substrate Over Concrete 1. Use 5/8” CD Exposure 1 Plywood subfloor panels, 4’ x 8’ sheets; cut sheets into 2’ x 8’ or 4’ x 4’ sections 2. Score the back of the panels half the thickness of the panel on a 12” x 12” grid in order to relieve tension in plywood 3. Use a 1/4” x 1/4” square-notched trowel to apply adhesive to concrete 4. Lay sections in a staggered joint pattern in the adhesive, with 1/8” spacing between sheets, and 3/4” minimum expansion space at walls and all vertical obstructions 5. Add weight as necessary to ensure adhesive remains in contact with plywood as it cures 6. Allow adhesive to dry overnight before proceeding with flooring installation
How To Get The Best Results Using Titebond 991 PROvantage ®
Subfloor Preparation All substrates must be clean, dry, structurally sound, properly cured and free of dirt, oil, paint, old adhesive, wax, sealers and curing agents. General scouring with 20 grit or #3 1/2 opencoat sandpaper will remove most compounds. All loose materials must be vacuumed from the surface after scouring. The subfloor must be flat to a tolerance of 3/16” in a 10’ radius. Hollow spots, popping spots and squeaks are related to unevenness in the subfloor. Grinding concrete floors is preferred over the use of filling compounds. If filling/leveling compounds are used, they must be portland based cementitious materials and have a compressive strength equal to or greater than 3000 psi when cured. Use of adhesive over light weight concrete and all gypsum based materials requires the use of Titebond Concrete Primer or equivalent prior to application of adhesive. For further information on Titebond Concrete Primer, contact Franklin Technical Service at 1-800-347-4583. Remove all existing base, shoe molding and door thresholds prior to continuing the installation. All door casings must be undercut with either a jamb saw or a hand saw. Use a piece of the flooring as a guide to determine the thickness needed.
Subfloor Moisture Check Titebond 991 PROvantage may be used for above-, on- and below-grade applications and on all substrates. All applications are susceptible to moisture and should be tested for moisture prior to installation in several locations within the installation area. Acceptable conditions of concrete for above-, on- and below-grade applications are: • Less than 3 lbs./1000 sq.ft./24 hours on a Calcium Chloride Test (ASTM F1869) • Less than a reading of 4.5 on a Tramex Concrete Moisture Encounter • Relative humidity (RH) of 75% or less when tested with an in situ probe (ASTM F2170). Acceptable conditions of wood substrates are a moisture reading of less than 12% or be no more than 4% different from the flooring being installed when using a Tramex, Delmhorst or equivalent wood moisture meter. If subfloor moisture conditions do not meet above guidelines at the time of flooring installation or they could exceed them at any time after installation, then Titebond 531 Moisture Control System may be used. For more information concerning these products and moisture conditions, call Franklin Technical Service at 1-800-347-4583.
Flooring Installation Using Titebond 991 PROvantage Wood Flooring Adhesive USE THIS PRODUCT ONLY IF ADEQUATE VENTILATION CAN BE PROVIDED. Use a properly fitted, air-purifying respirator with organic vapor cartridge that complies with all applicable standards while troweling this product. If proper ventilation cannot be provided, a different Titebond adhesive should be used. Call Franklin Tech Service at 1-800-347-4583 for product recommendations. Open doors and windows for cross ventilation and use fans to accelerate ventilation. Temporarily block vents and air returns during the installation to prevent the drifting of solvent vapors. All pilot lights and flame sources must be extinguished prior to installation and until solvent has evaporated. Titebond 991 PROvantage should be installed using the “wet lay” installation method and installer should not work on top of the wood. Titebond 991 PROvantage SHOULD NOT BE FLASHED. Begin laying the wood flooring immediately after troweling the adhesive with the correct trowel. To reduce slippage, secure the first two starter rows with starting blocks fastened to the substrate or wedges against starting wall. Work in small sections to ensure proper transfer of the adhesive to the wood flooring, placing remaining planks firmly into adhesive. Proceed in this manner until the field is complete, making sure to allow for proper expansion space around the room. Refer to flooring manufacturer for expansion spaces. After completion, wedge the flooring so that it remains tight during the drying process. Planks which are not flat should be weighted for several hours. Before leaving for the day, walk the floor and look for any defects or other cosmetic blemishes. This will also ensure the wood flooring is properly seated into the adhesive. After the adhesive has dried, remove and discard the wedges. Maintain ventilation for 24 hours after installation to remove any solvent vapors.
3
CAUTION STATEMENT
PHYSICAL PROPERTIES (TYPICAL) Type Advanced Solvent Color Beige Solids 67% Viscosity 125,000 cps @ 72˚F Weight/gallon 10.45 lbs.
Calculated VOC 6.3 g/L Flashpoint 7˚F (Pensky-Martens Closed Cup) Freeze/Thaw stability Not affected by freezing Storage life 1 year in tightly closed container
APPLICATION GUIDELINES Floor Type – Parquet & Engineered
Trowel Size
Coverage
• All parquets measuring less than 3/4” in thickness
1/8” x 1/8” x 1/8” Square-notch
Approximately 65 sq. ft. per gallon
• All engineered flooring Floor Type – Solid
3/16” x 1/4” x 11/16” c-c V-notch
Approximately 65 sq. ft. per gallon
• Solid flooring and bamboo with a width less than 3” and measuring 5/8” or less in thickness
3/16” x 1/4” x 1/2” c-c V-notch
Approximately 50 sq. ft. per gallon
• Solid flooring and bamboo with a width greater than 3” and measuring 5/8” or less in thickness, and 3/4” shorts
3/16” x 3/16” x 3/16” Square notch
Approximately 35 sq. ft. per gallon
CLEAN TROWEL OFTEN TO PREVENT ADHESIVE BUILD-UP Trowels: (not to scale)
Square-notch
V-notch
CLEANUP Wet and dried adhesive can be easily removed from surface with mineral spirits. Follow solvent vendor’s precautions. NOTE: Test solvent in an out-of-the-way area to make sure it will not mar or attack the surface. Call Franklin Technical Service at 1-800-347-4583 for specific cleaning instructions.
ORDERING INFORMATION Cat. No.
Size
8179
3.5 Gallon Metal Pail
Units/Case
Case Lbs.
Case/Pallet
1
40.53
36
WARRANTY INFORMATION Franklin International will honor the applicable terms of any wood floor manufacturer’s current published adhesive warranty or subfloor moisture warranty (where applicable) when the flooring was installed using Titebond 991 PROvantage Wood Flooring Adhesive in accordance with product instructions and the instructions of the wood floor manufacturer.* Franklin International will also warrant Titebond 991 PROvantage to be free from defects in materials and workmanship for a period of one year from the date of manufacture, if the product has been installed in accordance with the Franklin Specification Guide and the installation instructions furnished with the product. In the event of loss of adhesion of Titebond 991 PROvantage due to product defect, Franklin International will reimburse the customer for the cost of labor and materials necessary to repair or replace the affected area(s) of the installed wood flooring.
DANGER: EXTREMELY FLAMMABLE. VAPOR HARMFUL. Contains methyl acetate, oxydipropyl dibenzoate and residual vinyl acetate. Keep away from heat, sparks and flame. Wear appropriate personal protective equipment when handling and using. Use only with positive cross-ventilation. Avoid breathing vapors. Do not swallow. Do not allow eye contact or prolonged skin contact. Uncured product can cause eye or skin irritation. Prolonged or repeated overexposure to solvents in uncured product can cause central nervous system, peripheral nervous system, eye, skin, liver, kidney or respiratory system effects. First Aid: If dizziness or other adverse effects are experienced, move to fresh air; contact physician if discomfort persists. If eye contact occurs, flush eyes with water for 15 minutes; contact physician immediately. If swallowed, do not induce vomiting; contact physician immediately. Wash skin contact areas with soap and water; contact physician if irritation persists. Read Material Safety Data Sheet before using this product. KEEP OUT OF THE REACH OF CHILDREN. Important Notice: Our recommendations, if any, for the use of this product are based on tests believed to be reliable. Furthermore, nothing contained herein shall be construed as a recommendation to use any product in conflict with existing laws and/or patents covering any material or use.
*Any and all addendums or changes to the wood floor manufacturer’s warranties will be reflected in the execution of Franklin International’s warranty immediately upon release by the wood floor manufacturer. The effective date of said changes and addendums will dictate coverage by Franklin International in relation to the date of installation. As Franklin International is honoring the applicable terms of all wood floor manufacturers’ current published warranties, Franklin International will also require the same jobsite preparations and installation instructions that accompany each warranty in question. In the case of subfloor moisture warranties, Franklin International will cover cupping and buckling of the wood floor when the wood floor manufacturer names coverage of these phenomenon explicitly in their subfloor moisture warranty (where applicable), if all installation and subfloor preparation guidelines have been followed.
For more information on Titebond Flooring Products, please visit:
www.titebond.com
2020 Bruck Street, Columbus, Ohio 43207
Customer Service 1-800-669-4583 Technical Service 1-800-347-4583
Supersedes all previously published materials.
4