Transcript
FEATURES CHECK LIST
Industrial Cameras
www.baslerweb.com
Mainstream Area Scan Cameras scout Series
A100
A600
n
scout Series
aviator
n
pilot Series
ace
n
aviator
ace
Basler Cameras
ace
www.baslerweb.com/products
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
Interface STANDARD FEATURES Configurable Input/Output Lines
n
Adjustable Camera Link Pixel Clock Speed
n
Selectable Camera Link Baud Rate Adjustable Gain All
n
n n
n
n
n
Individual Tap Gain Adjustment Adjustable Black Level All
n
n
n
Individual Tap Black Level Adjustment Manual White Balance*
n
Digital Shift*
n
Area of Interest
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
Prelines Automatic White Balance*
n
n
n
n
n
n
n
n
Automatic Gain Control*
n
n
n
n
n
n
n
n
Automatic Exposure Control*
n
n
n
n
n
n
n
n
Auto Function Profile*
n
n
n
n
n
n
n
n
Binning up to 4 x 4* (Mono)
n
n
n
n
n
n
n
n
Color Binning*
n
n
n
n
n
n
n
n
Decimation Vertical
n
n
Stacked Zone Imaging*
n
n
Reverse X (Horizontal Mirroring)
n
n
Reverse Y (Vertical Mirroring)
n
n
n
Lookup Table
n
n
n
n
n
n
n
n
Gamma Correction (User)
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
sRGB Gamma Correction*
n
Enhanced Color*
n
User Defined Values
n
n
n
n
n
Remove Parameter Limits
n
n
n
n
n
n
n
n
Debouncer
n
n
n
n
n
n
n
n
Minimum Output Pulse Width*
n
n
n
n
n
n
Trigger Delay
n
n
n
n
n
n
n
n
Acquisition Status
n
n
n
n
n
n
n
n
Event Reporting
n
n
n
n
n
n
Test Images
n
n
n
n
n
n
n
n
n
n
Device Information Parameters
n
n
n
n
n
n
n
n
n
n
Configuration Sets
n
n
n
n
n
n
n
Temperature Readout Flash Window Signal*
n
Trigger Wait / Trigger Ready Signal*
n
Exposure Active Signal
n
Sequencer
n
n
n
n
n
n
n
n
n
n
n
n n
n
Device Link Troughput Limitation
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
CHUNK FEATURES Time Stamp
n
Trigger Input Counter
n
I/O Line Status
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
DCAM Values
n
n
n
n
Gray Value Stamp*
n
CRC Checksum
n
n
Frame Counter
n
n
Sequence Set Index*
n
n
n
n
n
Exposure Time
n
n
n
n
n
Gain Value
n
n
*This feature may not be available on all camera versions
2
n
n
n
n
n
n
n
n
n
n
Mainstream Area Scan Cameras
ace
ace
aviator
aviator
pilot Series
scout Series
scout
A100
A600
Basler Cameras
ace
www.baslerweb.com/products
n
n
n
n
n
n
n
n
n
n
Interface SOFTWARE Software Triggering PIXEL DATA FORMATS Mono 8 Mono 10* Mono 12 Mono 16* Mono 12 Packed* YUV 4:2:2 Packed (Ylber 422) YUV 4:2:2 (YUYV) Packed Raw 8 RGB 8 Packed* RGB 8* Bayer GB 8* Bayer RG 8* Bayer BG 8* Bayer GR 8* Bayer GR 10* Bayer BG 12* Bayer GB 12* Bayer GR 12* Raw 16 Bayer GB 16* Bayer BG 16* Bayer GB 12 Packed* Bayer BG 12 Packed* HARDWARE 90° Head Housing Inputs Outputs General Purpose I/O CAMERA LINK TAP GEOMETRIES 1X-1Y 1X2-1Y 1X3-1Y 1X4-1Y 1X6-1Y 1X8-1Y 1X10-1Y 1X-2YE
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
4 4
4 4
n n n
n
n
n
n
n
n
n
n
n
n
n
n
n
n n n
n
n
n
n
n
n
n
n
n
n
n
n
n
n n
n n
n n
n n
n n n n
n
1 1 1
1 1 2
2 4
2 1
n n
n
n n n n n n
*This feature may not be available on all camera versions
3
n
n
n
n
n
n
n
2 4
2 4
n
2 4
Line Scan Cameras
n
L304kc
n
L301kc
runner
n
sprint
racer
Basler Cameras
racer
www.baslerweb.com/products
n
n
Interface STANDARD FEATURES Configurable Input/Output Lines Selectable Camera Link Pixel Clock Speed Selectable Camera Link Baud Rate Adjustable Gain Analog Gain Digital Gain Gain Red* Gain Green* Gain Blue* Gain Green 2* Offset Red Offset Green Offset Blue Individual Tap Gain Adjustment Adjustable Black Level All (Offset) Indivitual Tap Black Level Adjustment Digital Shift AOI (Area of Interest) Time Delayed Line Sum/Average Offset Shading (DSNU Shading Correction) Gain Shading (PRNU Shading Correction) Automatic Gain Control* Automatic Exposure Control* Automatic Function Profile* Manual White Balance* Binning Lookup Table Gamma Correction User Defined Values Remove Parameter Limits Rotary Encoder Module Frequency Converter Spatial Correction (Color) Debouncer* Trigger Delay Acquisition Status Event Reporting Test Images Device Information Configuration Sets Temperature Readout Trigger Wait/Trigger Ready Signal* Exposure Active Signal Stamp Features* Error Condition Detection Inversion of Direction* Exposure Time Control Dark Noise Cancellation Heat Dissipation (Optional) CHUNK FEATURES Frame Counter Time Stamp Input Status @ Line Trigger CRC Checksum Trigger Counters Encoder Counter
n
n
n n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n n
n
n
n
n
n
n
n
n n
n
n
n
n n n
n
n
n n
n
n
n n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n n
n n
n n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n n
n n
n
n
n
n
n n
n
n
n
n
n
n
n n
n
n
n
n
n
n
n
n
n
n
n
n
n
* This feature may not be available on all camera versions
4
n
n
Line Scan Cameras
n
L304kc
n
L301kc
runner
n
sprint
racer
Basler Cameras
racer
www.baslerweb.com/products
n
n
Interface SOFTWARE Software Triggering PIXEL DATA FORMATS Mono 8 Mono 12 Mono 16 Mono12 Packed YUV 4:2:2 Packed YUV 4:2:2 (YUYV) Packed 8 Bit Output 10 Bit Output 12 Bit Output 16 Bit Output (12 Bits Effective) HARDWARE Inputs Outputs CAMERA LINK TAP GEOMETRIES 1X 1X2 1X3* 1X4* 1X6* 1X8 1X10 1X16* 4X2*
n
n
n n n
n
n
n
n
3 2
n n
n
n
n
n
n
n
n
n
n
2 1
2 4
1 1
n
n
n
n
n
n
n
n
n
n
n
n
4** 1***
3 2
n n
n
n n n
* This feature may not be available on all camera versions ** CC1 to CCF4 *** via Camera Link spare bit Note: The terminology used here to describe the features on GigE cameras complies with the GigE Vision standard. Accordingly, the terminology used to describe DCAM compliant cameras may differ. Specifications are subject to change without prior notice.
5
FEATURES CHECK LIST
www.baslerweb.com
What Makes Basler Camera Quality So Special? EMVA 1288 Compliance Basler is a leading company in the push for standardizing the measurement and presentation of machine vision sensor and camera specifications. All measurements performed by Basler will be 100% compliant with EMVA standard 1288 (Standard for Measurement and Presentation of Specifications for Machine Vision Sensors and Cameras). Basler has given this standard its strongest support. Basler helped to develop the unified method used to measure, compute, and present the specification parameters for cameras and image sensors used in machine vision applications. The EMVA 1288 standard includes a well defined method for measuring most common noise sources. It also includes a mandatory and detailed description of the measurement setup, environmental conditions, and test requirements.
As a first step, only the standardization process for monochrome area scan cameras is covered. An expansion covering the standards for color area scan and line scan cameras is expected to follow. The signal-to-noise ratio chart provides information on the image quality and sensitivity for a tested camera. The chart describes the development of the signal-tonoise ratio from a low level, where noise overlays the signal, up to the point of saturation. It also embeds camera parameters, such as full well, dynamic range, and the signal-to-noise ratio, for selected points on the curve that are relevant to a specific application. The EMVA 1288 standard is available at www.emva.org. A detailed technical white paper describing the measurement methods used in the standard can be downloaded from www.baslerweb.com.
Accessories for Basler Cameras Basler offers a wide variety of accessories designed to help you get the most out of your camera. To ensure full compatibility, all accessories are tested with our cameras. Cables and power supplies are all EMC proven by our support team for industrial conditions. Our portfolio includes several accessories in each of the following categories: Cables
Optics
Connectors
Power Supplies
Frame Grabbers and Cards
Tripod Mounts
Lens Mounts
Others
You can view the entire accessories portfolio, including order numbers and data sheets, at our website: www.baslerweb.com/accessories.
© Basler AG, 01/2014
For information on Disclaimer of Liability & Privacy Statement please see www.baslerweb.com/disclaimer Basler AG Germany, Headquarters
USA
Singapore
Taiwan
Tel. +49 4102 463 500
Tel. +1 610 280 0171
Tel. +65 6367 1355
Tel. +886 3 558 3955
Fax +49 4102 463 599
Fax +1 610 280 7608
Fax +65 6367 1255
Fax +886 3 558 3956
[email protected]
[email protected]
[email protected]
[email protected]
China (Shanghai)
China (Shenzhen)
Korea
Tel. +86 21 6230 2160
Tel. +86 181 2395 6667
Tel. +82 70 7136 3114
Fax +86 21 6230 0251
Fax +86 21 6230 0251
Fax +82 70 7016 2705
[email protected]
[email protected]
[email protected]
www.baslerweb.com