Preview only show first 10 pages with watermark. For full document please download

Fiamm Fg Battery - Blue Box Batteries

   EMBED


Share

Transcript

SSLA SSLA Battery Range FIAMM.COM T HE SSLA BATTERY RANGE HAS BEEN DESIGNED TO MAIN APPLICATIONS: COVER A WIDE RANGE OF APPLICATIONS. THE FOOTPRINT OF BATTERIES IS ALSO IDEAL FOR CRITICAL INSTALLATIONS. CONNECTION IS SIMPLE ON SMALLER MODELS SIZES THANKS TO THE EASY ‘FAST-ON’ TERMINALS. THE FIAMM SSLA RANGE HAS FOUR DIFFERENT PRODUCT FAMILIES. EACH ONE IS SPECIFICALLY DESIGNED TO OPTIMISE U PS THE BEST SOLUTION FOR THE APPLICATION. FG DESIGNED TO MEET MEDIUM TO LONG DISCHARGE RATES AND WITH A DESIGN LIFE OF 5 YEARS. THE RANGE IS AVAILABLE IN 6V OR 12V BLOCKS WITH A CAPACITY RANGE OF 1.2 - 70AH. FGH DESIGNED FOR MAXIMUM PERFORMANCE IN CRITICAL POWER APPLICATIONS SUCH AS UPS. THE RANGE IS AVAILABLE IN 12V BLOCKS WITH A CAPACITY RANGE OF 5 - 18AH. FGHL CLASSIFIED “LONG LIFE” ACCORDING EUROBAT INDUSTRY SECURITY SYSTEMS AND EMERGENCY LIGHTING STANDARD, WHICH MEANS 10 YEARS DESIGN LIFE. THE RANGE IS AVAILABLE WITH A CAPACITY RANGE OF 5AH TO 12AH. FGC AN IDEAL SOLUTION FOR CYCLIC APPLICATIONS WITH A DESIGN LIFE OF 5 YEARS. RANGE IS AVAILABLE FROM 12 – 42AH. THESE PRODUCTS ARE DESIGNED TO GIVE A WIDE RANGE OF SOLUTIONS TO ALL APPLICATIONS AND OFFER UNSURPASSED PROVEN RELIABILITY, RECOGNISED COMPLIANT INTERNATIONAL WITH STANDARDS. THE HIGHEST SSLA USES LI GHT T RAC T ION VRLA TECHNOLOGY WITH 99% INTERNAL RECOMBINATION EFFICIENCY, IS NON-SPILLABLE AND MAINTENANCE FREE THEREFORE REQUIRES NO TOPPING UP OF ELECTROLYTE DURING ITS FLOAT-LIFE. SSLA RANGE IS NON-HAZARDOUS FOR AIR/SEA/RAIL/ROAD TRANSPORTATION AND IS 100% RECYCLABLE. SLA HAS A SELF-DISCHARGE RATE LESS THAN 2% PER MONTH, GUARANTEEING LONG SHELF-LIFE. LEISURE *SSLA (SMALL SEALED LEAD ACID) ARE BATTERIES WITH CAPACITY (AH) TILL MAX 24AH. THE FIAMM SSLA FIAMM RANGE CONTAINS SOME SIZES THAT EXCEED THIS LIMIT. HOWEVER SOME SIZES ARE OF A LARGER CAPACITY DUE TO APPLICATIONS. SPECIFICATIONS High purity lead calcium tin grid plates, designed to resist corrosion and provide short recharge time VRLA AGM technology using low resistance high microporous fiberglass separators Leak resistant post seal, faston, flag and threaded female, terminals with high conductivity and maximum torque resistance One-way safety relief valves allow gas to escape and prevent the ingress of oxygen ABS plastic (for FGHL range flame retardant ABS plastic to IEC 707 FV0 and UL94 FV0 - LOI greater than 28%) Installation in any orientation (excluding permanently inverted) TERMINALS TYPE Faston 4.8 4.75 Faston 6.3 6.35 Flag Ø 5.5 Ø5.5 Flag Ø 6.5 Ø6.5 Round M5 M5 Round M6 M6 TECHNOLOGY Terminal Pillar Internal Strap Separators Negative Flat Plate The image is for illustrative purposes only. F I A M M S S L A R A N G E U S E A G M ( A B S O R B E D G L A S S M AT ) T E C H N O L O G Y. T H E E L E C T R O LY T E I S A B S O R B E D I N F I B E R G L A S S S E PA R AT O R S W I T H 9 9 % I N T E R N A L G A S R E C O M B I N AT I O N E F F I C I E N C Y. BLOCS ARE GRANTS NON-SPILLABLE AND MAINTENANCE FREE THEREFORE REQUIRES NO T O P P I N G U P O F E L E C T R O LY T E D U R I N G I T S W H O L E L I F E . L O W S E L F - D I S C H A R G E A L L O W S 6 MONTHS SHELF LIFE. FG BATTERY TYPE VDS* CAPACITY (Ah) NOMINAL DIMENSIONS (mm) 20 H to 1.75 VPC at 25°C Length Width Height Tot. Height** TYPICAL WEIGHT (kg) 6 1.2 97 24 51 58 0.28 Faston 4.8 6 3.0 134 33 60 66 0.60 Faston 4.8 FG 10381 6 3.8 66 33 119 125 0.61 Faston 4.8 FG 10451 6 4.5 70 47 101 106 0.72 Faston 4.8 FG 10721 6 7.2 150 34 94 100 1.2 Faston 4.8 FG 10121 t FG 10301 NOMINAL VOLTAGE (V) TERMINAL TYPE FG 11201 t 6 12 151 50 93 99 1.8 Faston 4.8 FG 11202 t 6 12 151 50 93 99 1.8 Faston 6.3 FG 20121 t 12 1.2 97 48 51 57 0.54 Faston 4.8 12 1.2 97 43 51 58 0.52 Faston 4.8 12 2.0 178 35 60 65 0.80 Faston 4.8 FG 20271 12 2.7 79 56 99 105 1.1 Faston 4.8 FG 20341 12 3.4 134 65 60 66 1.3 Faston 4.8 FG 20451 12 4.5 90 70 101 107 1.5 Faston 4.8 FG 20121A t FG 20201 FG 20721 t 12 7.2 151 65 95 101 2.3 Faston 4.8 FG 20722 t 12 7.2 151 65 95 101 2.3 Faston 6.3 FG 21201 t 12 12 151 98 95 100 3.8 Faston 4.8 FG 21202 t 12 12 151 98 95 100 3.8 Faston 6.3 FG 21803 t 12 18 181 76 167 167 5.5 Flag Ø5.5 FG 22703 t 12 27 166 175 125 125 8.7 Flag Ø5.5 FG 24204 t 12 42 197 165 170 170 13.5 Flag Ø5.5 FG 27004 t 12 70 350 166 174 174 23.3 Flag Ø6.5 * Model available also with VDS **Tot. Height = total height including terminals FGC BATTERY TYPE NOMINAL VOLTAGE (V) CAPACITY (Ah) INTERNAL RESISTANCE (mOhm)  NOMINAL DIMENSIONS (mm) 20 H to 1.75 VPC at 25°C IEC 60896 21-22 Length Width Height Tot. Height* TYPICAL WEIGHT (kg) TERMINAL TYPE FGC 21202 12 12 13 151 98 95 100 4.0 Faston 6.3 FGC 21803 12 18 12 181 76 167 167 6.3 Flag Ø5.5 FGC 22705 12 27 11 166 175 125 125 9.2 Round M5 FGC 23505 12 35 6.5 197 132 170 170 12.2 Round M5 FGC 24207 12 42 7.5 196 165 169 169 13.2 Round M6 *Tot. Height = total height including terminals FIAMM reserves the right to change or revise without notice any information or detail given in this publication SSLA Battery Range_2016_06_15 FGH BATTERY TYPE NOMINAL VOLTAGE (V) CAPACITY (Ah) INTERNAL RESISTANCE (mOhm)  NOMINAL DIMENSIONS (mm) 20 H to 1.75 VPC at 25°C IEC 60896 21-22 Length Width Height Tot. Height* TYPICAL WEIGHT (kg) TERMINAL TYPE 12 FGH 23 slim 12 5.0 37 151 51 95 102 2.2 Faston 4.8 12 FGH 23 12 5.0 37 90 70 101 107 2.1 Faston 6.3 12 FGH 36 12 9.0 23.6 151 65 95 101 2.7 Faston 6.3 12 FGH 50 12 12 14.8 151 98 95 100 4.2 Faston 6.3 12 FGH 65 12 18 9.8 181 76 167 167 6.2 Flag Ø5.5 TYPICAL WEIGHT (kg) TERMINAL TYPE *Tot. Height = total height including terminals FGHL BATTERY TYPE NOMINAL VOLTAGE (V) CAPACITY (Ah) INTERNAL RESISTANCE (mOhm)  NOMINAL DIMENSIONS (mm) 20 H to 1.75 VPC at 25°C IEC 60896 21-22 Length Width Height Tot. Height* 12 FGHL 22 12 5.0 37 90 70 101 107 2.1 Faston 6.3 12 FGHL 28 12 7.2 24.6 151 65 95 101 2.7 Faston 6.3 12 FGHL 34 12 9.0 23.6 151 65 95 101 2.8 Faston 6.3 12 FGHL 48 12 12 24.8 151 98 95 100 4.2 Faston 6.3 *Tot. Height = total height including terminals ELECTRICAL CHARACTERISTICS STANDARDS Float Voltage: 2.25-2.30 V/cell at 25°C Boost Voltage for cyclic use: 2.40-2.50 V/cell at 25°C Float Voltage Compensation with Temperature: -2.5 mV/cell/°C Self-Discharge at 25°C: <2%/month IEC 60896 Part 21 - VRLA methods of testing IEC 60896 Part 22 - VRLA requirements BS 6290 Part 4 - specifications for VRLA classification Eurobat “3-5 years standard commercial” for FG FGH FGC and “10-12 years long life” for FGHL UL Recognized CERTIFICATIONS ISO 9001 Quality Management System ISO 14001 Environmental Management System OHSAS 18001 Workplace Safety & Health DISCHARGE CURVES at different current / final voltage (at 25°C) 2.2 Battery Voltage (V/cell) 2.1 2.0 1.9 1.8 0.05 C 1.7 0.10 C 0.26 C 1.6 2.60 C 2 C 1.22 C 0.68 C 1.5 10 100 10.000 1.000 Discharge time (min) The above discharge curves are typical. For more detailed information please see the specific product sheets. STORAGE Battery Voltage and Charge Time for Standby Use (at 25°C) Capacity loss during storage at various temperatures 120 100 80 15 0.10 C10 60 40 0.05 C10 13 12 11 0 0 10 0 0 5 10 15 20 5°C 60 Refreshing charge of 2.4 Vpc may be insufficient to recover the battery capacity. It is important to avoid this area Charging Current (A) Discharge 100% 50% 80 Refreshing charge at 2.4 Vpc for 24 hours (at 20-25°C) must be applied as soon as possible. Recharged Capacity (%) 20 100 The battery can be used without refreshing charge Battery Voltage (V) 14 Charging Voltage (V) Recharged Capacity (%) 140 Charging Current (A) TYPICAL CHARGE CURVES Charging time (h) 2 4 6 8 10 12 14 Storage Time (months) FIAMM S.p.A. V i a l e E u r o p a , 7 5 - 3 6 0 7 5 M o n t e c c h i o M a g g i o r e ( V I ) - I TA LY TEL +39 0444 709311 25°C 40 0 25 30°C 40°C - Fax +39 0444 694178 e-mail: [email protected] w w w. f i a m m . c o m fiamm.batteries fiammbatteries youtube.com/user/FIAMMvideo 16 18 20 Remaining Capacity (%) 1