- Platform for the NGCS - Improves bandwidth for advanced services - Fiber deep node - Innovative coast effective design - Compact size - Services for commercial and residential application The model N8702 is NetWave’s latest generation 870MHz optical node Platform. This platform allows a maximum value node for service provider who are looking for the fiber deeper into new and current HFC network. The N8702 offers the flexibility to function as a single output node in fiber deep architectures. The N8702 is the perfect solution for increasing bandwidth and revenues with limited capital expenditures. 1550nm region CWDM return transmitters allows system operators to maximize the benefit of reduced number of return path fiber cables. The standard features include 15Amps power passing capability, Crowbar surge protection and plus the deeper lid contain a fiber tray plus, option module of the Network Monitoring transponder.
9
Optical Transmitter
Optical operating wavelength : 1310 ± 10nm Laser type : FP / DFB LD Fiber Connector : SC / APC Optical power ( nominal ) : FP : 1mW, DFB : 3mW RF Operating bandwidth : 5 to 42MHz
9
Optical Receiver
Optical operating wavelength : 1310 ± 20nm or 1550 ± 20nm Photodiode type : Hybrid dynamic range PIN diode Fiber Connector : SC / APC type Optical input range : -3.0 to +2.0 dBm RF Operating bandwidth
9
RF Amplifier module
RF Operating bandwidth : 5 ~ 870MHz ( 5~42MHz, 54 ~ 870MHz) Impedance : Nominal 75 ohm Operating power voltage : +5,+12,+24VDC AC Power passing is capable the each port. Plug-in Equalizer and Attenuator. 40/90 or 110 Volt powering
Specifications Optical Section • Wavelength • Optical input Range • Indicators (Voltage) • Accuracy • Return Loss • Connector • Housing Pass Band
1310 and 1550 ±20nm -3 ~ +2 dBm 1V / mW 1dB ≥ 55 dB SC/APC Type 5 to 1002 MHz
RF Section
Forward
• Bandwidth • Frequency Response • Operation Gain(@870MHz) • Reference Out Level@
(Optical input 0dBm ) • Operation Slope • Attenuation by pads (level adjust) • Equalizer by pads • CTB (Composite Triple Beat) • CSO (Second Oder Beat) • X-MOD (Cross Modulation ) • CIN (Carrier-to-Intermodulation Noise) • HUM-MOD@15A • Noise Figure • Return Loss • Test Point, all Accuracy
Reverse
54MHz ~ 870MHz ± 0.75 dB >45 dB 870 / 550 / 55 MHz 48.5 / 35 / 26 dBmV 55 / 550 / 870 MHz 0 / 9 / 13.5 dB Plug-in type 0-20 dB Plug-in type -3 to 20 dB < -67 dBc (127dB㎶) < -65 dBc (125dB㎶) < -63 dBc (123dB㎶) 52 dBc < -65 dBc (125dB㎶) < 7 dB < - 16dB ± 0.1 dB
5MHz ~ 42MHz ± 0.75 dB >17 Flat dB 19.5 (@42/65MHz) dBmV Plug-in Type 0-20 dB Plug-in Type 0-12dB < -60 dBc (120dB㎶) < 6 dB < - 16dB ± 0.1 dB
Environmental • Operating Temperature Range • Storage Temperature Range • Humidity Range
- 40 ~ +65 ℃ / -40 ~ +149º F - 40 ~ +70 ℃ / -40 ~ +158º F 0 ~ 95 %
Power Requirements (with AGC) • Line Power AC Input Voltage • Power Consumption • DC Voltage • AC Bypass current • DC Current • AC Voltage, 60Hz
60 ~ 90 VAC 23 W + 24.0 ±0.25 V 15A 600mA @40 / @50 / @60 / @70 / @80 / @90 VAC 1.08 / 0.85 / 0.72 / 0.64 / 0.58 / 0.53 A
Mechanical • Weight • Housing Dimension
7.5 Kg 367× 229× 190 (W×H×D) mm
www.net-wave.co.kr
Specifications Optical Section Wavelength
1310 and 1550 ±20nm
Optical input Range
-3 ~ +2 dBm
Indicators (Voltage)
1V / mW
Accuracy
1dB
Return Loss
≥ 55 dB
Connector
SC/APC Type
Housing Pass Band
5 to 1002 MHz
RF Section
Forward
Reverse
Bandwidth
54MHz ~ 870MHz
5MHz ~ 42MHz
Frequency Response
± 0.75 dB
± 0.75 dB
Operation Gain(@870MHz)
>45 dB
>17 Flat dB
Reference Out Level@ (Optical input 0dBm)
870 / 550 / 55 MHz 48.5/ 35 / 26 dBmV
19.5 (@42/65MHz) dBmV
Operation Slope
870 / 550 / 55 MHz 13.5/ 9 / 0 dB
-
Attenuation by pads (level adjust) Plug-in type 0-20 dB(1.0dB Step)
Plug-in Type 0-20dB(1.0dB Step)
Equalizer by pads
Plug-in type -3 to 20 dB(1.5dB Step)
Plug-in Type 0-12dB(1.5dB Step)
CTB (Composite Triple Beat)
< -67 dBc (127dB㎶)
-
CSO (Second Oder Beat)
< -65 dBc (125dB㎶)
-
X-MOD (Cross Modulation )
< -63 dBc (123dB㎶)
-
CIN(Carrier-to-Intermodulation Noise) Opitcal Input 0dBm
52 dBc
-
HUM-MOD@15A
< -65 dBc (125dB㎶)
< -60 dBc (120dB㎶)
Noise Figure
< 7 dB
< 6 dB
Return Loss
< - 16dB
< - 16dB
Test Point, all Accuracy
± 0.1 dB
± 0.1 dB
www.net-wave.co.kr
Specifications & Block Diagrams Environmental Operating Temperature Range - 40 ~ +65 ℃ / -40 ~ +149º F Storage Temperature Range Humidity Range
- 40 ~ +70 ℃ / -40 ~ +158º F 0 ~ 95 %
Power Requirement Line Power AC Input Voltage 60 ~ 90 VAC Power Consumption
23 W
DC Voltage
+ 24.0 ±0.25 V
AC Bypass current
15A
DC Current
600mA
AC Voltage, 60Hz ,@VAC/A @40/1.08A , @50/0.85A , @60/0.72 , @70/0.64 , @80/0.58 , @90/0.53A
Mechanical Weight
7.5 Kg
Housing Dimension
367× 229× 190 (W×H×D) mm
Optical INPUT Photo Diode
Factory Trim
PAD #1
H
PAD #2
FWD Equalizer
AMP
L
AC Bypass
RF Output 1
AMP Optical Monitoring Alarm LED
Opt. Monitor (1V/ mW)
PAD #3
-20dB. RF Input Monitor
PAD #3
AC Fuse
-20 dB Fwd. RF Monitor Reverse Injection PAD #4
RF AMP 1310nm Laser Diode
AC Fuse Low Pass Filter
PAD #6
Optical Output
AMP
Optical Monitoring Alarm LED
Opt. Monitor (1V/ mW)
-20 dB Reverse. RF
L
PAD #5
AC Bypass
RF Output 2
Reverse Transmitter Shield Enclosure
+24 / +12 / +5 VDC
H
Power Supply
-20 dB Fwd. RF Monitor Reverse Injection