Preview only show first 10 pages with watermark. For full document please download

Fiber Optic Cable For The Nuclear Power Industry

   EMBED


Share

Transcript

2014 Fiber Optic Cable for the Nuclear Power Industry Partnership RSCC Wire & Cable LLC (Rockbestos Surprenant Cable Corporation) and AFL entered into a partnership for the development of fiber optic cables and releated components into the resurging nuclear power market in early 2010. Both companies have a long history of supplying specialty cables into utility and harsh environments where high levels of reliability are vital. Even prior to the agreement, the partnership was already impacting the nuclear cable market with new developments including specialty radiation resistant fiber, highly flame retardant cables, and the development of Thermoset Low Smoke Zero Halogen jacketed fiber optic cables for indoor/outdoor use. RSCC brings extensive knowledge of polymers specifically designed for utilization in radiation and harsh environments. As a world leader in the design and manufacture of insulated high performance control, power, instrumentation, and specialty cables to the nuclear marketplace, RSCC is unparalleled in their harsh environment test capabilities. RSCC has over 40 years of nuclear experience and an NUPICS audited 10CFR 50 Appendix B QA program. In addition, RSCC is a nuclear cable supplier with ISO 9001 and NQA-1 approvals. AFL is an industry leader in providing fiber optic products, engineering expertise and integrated services to the data, utilities, and specialty markets. Over 30 years of fiber optic cable experience enables AFL to provide effective fiber optic solutions and engineering support. AFL’s optical fiber capability and specialty cable manufacturing, combined with RSCC’s comprehensive knowledge of radiation and harsh environment resistant polymers, fills an essential need for the nuclear industry in the digital age. RSCC-AFL is committed to meeting our customers’ requirements through collaborative efforts in pursuit of innovation, manufacturing excellence, and unrivaled customer service. www.R-SCC.com or (860) 653-8300 © 2011, AFL, all rights reserved. Revision 0, 01.12.11 Specifications are subject to change without notice. Table of Contents Fiber Optic Cable Armored Harsh Environment Cable. . . . . . . . . . . . . . . . . . . . . . . . 2 Low Smoke Zero Halogen (LSZH), Indoor/Outdoor Loose Tube Cable with Thermoset Jacket. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Indoor/Outdoor, Low Smoke Zero Halogen (LSZH) Breakout Cable. . 5 Low Smoke Zero Halogen Distribution Cable. . . . . . . . . . . . . . . . . 7 PVDF Jacketed, Plenum Distribution Cable. . . . . . . . . . . . . . . . . . . 9 Deployable Cable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Fiber Optic Cable Assemblies . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Fusion Splicing FSM-60S Fusion Splicer Kit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Test and Inspection C860 QUAD OTDR and Certification Test Kit . . . . . . . . . . . . . . . . 16 OFS 300 Optical Microscope. . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 DFS1 Digital FiberScope. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 VFI2 and HiLite Visual Fault Identifiers. . . . . . . . . . . . . . . . . . . . . 25 SMLP5-5 Test Kit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 M210 Multifunction Micro OTDR . . . . . . . . . . . . . . . . . . . . . . . . 28 Cleaning Supplies One-Click Cleaner Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Cletop Cassette Cleaner Series. . . . . . . . . . . . . . . . . . . . . . . . . . 32 www.R-SCC.com or (860) 653-8300 1Q13 11 Armored Harsh Environment Cable Armored Harsh Environment cables utilize AFL’s patented, laser welded tube to technology which provide a hermetically sealed package for the optical fibers within. The armor wires provide improved crush and tensile performance while enabling cable flexibility. 316 stainless steel wires provide strong corrosion resistance. PVC free, flame retardant jackets are available to provide additional long term corrosion and chemical resistance. Users can select gel-filled or gel-free tubes. Gel is useful in preventing water migration for outdoor applications. For indoor applications, gel can be used, but is not required. Armored Harsh Environment cables can be used in a variety of applications including those which require survivability and signal integrity during significant harsh environment generating events. These cables can be designed and tested for Class 1E safety related functions under an Appendix B and NQA-1 quality assurance program. Cable Components Optional Outer Jacket Armor Wires Shown with optional outer jacket Stainless Steel Tube Features • Hermetic Stainless Steel Tube • High Strength Wire • Jacket Options • Gel Options • Flexible • Rugged Applications • Tamper Resistant Campus Communication Cable • In-Containment • MSIV and Piping Penetration rooms • High Pressure and Temperature • Flooded spaces • Hazardous chemical areas Environmental Performance • Available with a wide variety of jacketing materials including: – Thermoplastic LSZH – Thermoset LSZH – PVDF Optional Gel Fiber String Binders (2) Designed to Meet the Following Industry Standards • IEEE 383-1974 • IEEE 1202 • Plenum, riser requirements met dependent on jacket seletion • ICEA S-83-596 (premise- indoor) • ICEA S-104-696 (indoor/outdoor) • ICEA S-87-640 (outdoor) Temperature Performance JACKET TYPE None None FIBER COATING TYPE Acrylate High Temp. Acrylate None Polyimide Thermoset LSZH High Temp. Acrylate TEMP. RATING (°C) -40 to +85 -40 to +150 -40 to +300 -25 to +90 NOTE: Other jacket types and fiber coatings available. Mechanical Data JACKET TYPE None None None None Thermoset LSZH Thermoset LSZH Thermoset LSZH Thermoset LSZH FIBER COUNT 2,4 6, 8,12 24, 36 48, 72 2, 4 6, 8,12 24, 36 48, 72 www.R-SCC.com or (860) 653-8300 TUBE O.D. STRANDED CORE O.D. in (mm) in (mm) .051 (1.3) .083 (2.1) .094 (2.4) .142 (3.6) .125 (3.2) .205 (5.2) .150 (3.8) .230 (5.8) .051 (1.3) .083 (2.1) .094 (2.4) .142 (3.6) .125 (3.2) .205 (5.2) .150 (3.8) .230 (5.8) JACKET O.D. in (mm) ­— — — — .142 (3.6) .197(5.0) .285 (7.3) .315 (8.0) WEIGHT lbs/1000ft (kg/km) 11 (16) 30 (45) 68 (101) 81 (121) 88 (25) 198 (56) 427 (120) 510 (144) © 2011, AFL, all rights reserved. Revision 0, 01.12.2011 Specifications are subject to change without notice. 2 Low Smoke Zero Halogen (LSZH), Indoor/Outdoor Loose Tube Cable with Thermoset Jacket Features • Fiber counts up to 144 • Low smoke zero halogen, thermoset jacket • Optional rodent resistant armor available • Resistant to lubricating oil (Mil-L-23699), hydraulic fluid (Mil-H-5606), gasoline and deionized water • NEC OFNG-LS listed • NEC OFCG-LS listed (steel armor option) • Minimizes the use of PVC consistent with guidance of NRC Regulatory Guide 1.189 “Fire Protection for Operating Nuclear Power Plants” • Gel-filled tubes provide maximum water-blocking capabilities to protect fibers • Cross-linked, cable jacket melt resistance exceeds 200°C • Suitable for cable tray installation Utilizing a thermoset (XLPO) jacket, RSCC-AFL’s LX-series low-smoke zero-halogen (LSZH) loose tube cables are specifically designed for industrial environments. Ideal for indoor and outdoor applications, the cable design includes dry-core water blocking system, SZ-stranding for easy mid-span access to fibers, and a highly chemical resistant, cross-linked, UV-resistant outer jacket. For even greater mechanical strength, a corrugated steel armor version is available. In addition to compliance to IEEE 383 flame testing, the OFN-LS listing provides additional third party testing and assurance that the cable family meets the minimum flame and smoke generation guidelines for cable tray installation and other general purpose inside building applications. Cable Components FRP central member water blocking layer strength member XLPO flame retardant LSZH jacket buffer tube with gel or optional dry water-blocking elements optical fibers optional inner jacket and steel armor rip cord Maximum Lengths SINGLE-MODE feet meters 23,000 7,000 FIBER COUNT 2 - 144 MULTIMODE feet 23,000 meters 7,000 Longer lengths may be available upon request. Testing Standards Temperature Range ANSI/ICEA S-104-696 Operating . . . . . . . . - 40ºC to + 70ºC Telcordia GR-20 Storage . . . . . . . . . - 50ºC to + 75ºC IEEE 383-1974, 2003 IEEE 1202 Installation. . . . . . . - 20ºC to + 60ºC Crush* Armored . . . . . . 550 N/cm (375 lbs/in) Non-armored . . . 440 N/cm (250 lbs/in) * Standard loose tube cables are 220 N/cm (125 lbs/in) continued on next page –> © 2011, AFL, all rights reserved. Revision 1, 03.31.2014 Specifications are subject to change without notice. www.R-SCC.com or (860) 653-8300 3 Low Smoke Zero Halogen (LSZH), Indoor/Outdoor Loose Tube Cable with Thermoset Jacket Ordering Information ITEM NUMBER FIBER COUNT NOMINAL DIAMETER inches mm NUMBER OF TUBES/FIBERS NON-ARMORED (OFNG-LS) – (92 & 144 fiber Count OFN-LS) 6 1w/6 (4 fillers) 0.47 RSLX006C5101N1 12 1w/12 (4 fillers) 0.47 RSLX012C5101N1 24 2w/12 (3 fillers) 0.47 RSLX024C5101N1 36 3w/12 (2 fillers) 0.47 RSLX036C5101N1 48 4w/12 (1 filler) 0.47 RSLX048C5101N1 60 5w/12 (no fillers) 0.47 RSLX060C5101N1 72 6w/12 (no fillers) 0.53 RSLX072C6101N1 96 8w/12 (no fillers) 0.57 RSLX096C8101N1 144 12w/12(no fillers) 0.724 RSLX144CC101N1 ARMORED (OFCG-LS) 6 1w/6 (4 fillers) 0.60 RSLX006C5111S1 12 1w/12 (4 fillers) 0.60 RSLX012C5111S1 1w/12,1w/6 (3 18 0.60 RSLX018C5111S1 fillers) 24 2w/12 (3 fillers) 0.60 RSLX024C5111S1 2w/12,1w/6 (2 30 0.60 RSLX030C5111S1 fillers) 36 3w/12 (2 fillers) 0.60 RSLX036C5111S1 48 4w/12 (1 filler) 0.60 RSLX048C5111S1 60 5w/12 (no fillers) 0.60 RSLX060C5111S1 72 6w/12 (no fillers) 0.63 RSLX072C6111S1 NOMINAL WEIGHT lbs/1,000 ft kg/km MAX. TENSILE LOAD - lbs (N) Short Term Long Term MIN. BEND RADIUS - in (cm) Short Term Long Term 11.9 11.9 11.9 11.9 11.9 11.9 13.5 14.5 18.4 92 92 91 91 90 90 105 121 226 137 137 136 136 134 134 156 180 336 600 (2670) 600 (2670) 600 (2670) 600 (2670) 600 (2670) 600 (2670) 600 (2670) 600 (2670) 600 (2670) 180 (800) 180 (800) 180 (800) 180 (800) 180 (800) 180 (800) 180 (800) 180 (800) 180 (800) 9.4 (24) 9.4 (24) 9.4 (24) 9.4 (24) 9.4 (24) 9.4 (24) 10.6 (27) 11.4(29) 14.48(36) 4.7 (12) 4.7 (12) 4.7 (12) 4.7 (12) 4.7 (12) 4.7 (12) 5.3 (13.5) 5.7(14.5) 7.24(18) 15.2 15.2 129 131 192 194 600 (2670) 600 (2670) 200 (890) 200 (890) 12.4 (32) 12.4 (32) 6.2 (16) 6.2 (16) 15.2 132 196 600 (2670) 200 (890) 12.4 (32) 6.2 (16) 15.2 132 196 600 (2670) 200 (890) 12.4 (32) 6.2 (16) 15.2 132 196 600 (2670) 200 (890) 12.4 (32) 6.2 (16) 15.2 15.2 15.2 16.1 132 132 132 153 196 197 198 228 600 (2670) 600 (2670) 600 (2670) 600 (2670) 200 (890) 200 (890) 200 (890) 200 (890) 12.4 (32) 12.4 (32) 12.4 (32) 13.0 (33) 6.2 (16) 6.2 (16) 6.2 (16) 6.5 (17)  Fiber Types-Replace asterisk () in part number with number corresponding to desired fiber type below. Diameter and weight subject to change without notice. (D) at end of item number indicates gel-free, dry water-blocked buffer tubes. Example: RSLX0129C5101N1(D) Optical Performance Information FIBER TYPE Grade-index Multi-mode Fibers (6) 62.5 Giga-Link 300 (8) 62.5 Giga-Link 1000 (5) 50 Giga-Link 600 (L) 50 Laser-Link 300 (OM3) (1) 100/140 Graded Index MM Fiber Step-index Singlemode Fibers (9) Singlemode (K) Futureguide SR-15e Bend Insensitive (AL) Radiation Resistant Singlemode OVERFILLED LAUNCH MINIMUM BANDWIDTH (MHz•km) MAXIMUM ATTENUATION (dB/km) 1300 850 nm nm 1310 nm 1550 nm 1 GIGABIT ETHERNET MINIMUM LINK DISTANCE (meters) 850 nm 1300 nm 850 nm 1300 nm 10GIGABIT ETHERNET MINIMUM LINK DISTANCE (meters) 850 nm 1300 nm (serial) (serial) 3.2 3.2 2.9 2.9 5.0 1.2 1.2 0.9 0.9 4.0 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 200 350 500 1500* 100 600 600 500 500 100 300 500 600 900 N/A 550 1,000 600 550 N/A 32 65 82 300 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 0.35 0.35 0.25 0.25 N/A N/A N/A N/A N/A N/A 5,000 5,000 N/A N/A 10,000 10,000 N/A N/A 0.35 0.25 N/A N/A N/A 5,000 N/A 10,000 * 50/125 Laser-Link 300 Effective Modal Bandwidth = 2000 MHz/Km in 850nm window for 10 Gigabit Ethernet Links as measured by Differential Mode Delay (DMD). • Gigabit Ethernet Link Distance are based on modal dispersion constraints. Actual link distance limits may also be constrained by attenuation, depending on customer’s specific loss budget. • Available with specialty fibers (ex. 200/230, specialty coatings, radiation hardened options). Consult with our engineering specialists to select the best fiber for your application. © 2011, AFL, all rights reserved. Revision 1, 03.31.2014 Specifications are subject to change without notice. www.R-SCC.com or (860) 653-8300 4 Indoor/Outdoor, Low Smoke Zero Halogen (LSZH) Breakout Cable Features • Semi-pressure extruded, flame retardant, LSZH jacket resistant to fungus, water and UV • Minimizes use of PVC consistent with NRC Regulatory Guide 1.189 “Fire Protection for Operating Nuclear Power Plants” • Each fiber in 2.4 mm subcable for added mechanical protection and higher strength terminations • NEC OFNR-LS Listed • Aramid between subcables and outer jacket provides additional strength • Crush Resistance: 2200 N/cm (1500 lbs/in) (EIA-455-41A) • Impact Resistance: 1500 impacts at 2.94 N-m (EIA-455-25) • Flex Cycles: 400 Cycles (EIA-455-104) • Subcables numbered every 6 inches • Meets or exceeds: - ANSI/ICEA S-104-696 (Indoor/Outdoor) - Telcordia GR-409 (General Purpose, Horizontal Backbone Cable, Weatherized) - IEC 60794-2-21 (I/O Multi-Fiber Distribution) • Subcables meet Telcordia GR-409 interconnect requirements • Water blocked core & subunits meets water penetration requirements of IEC 60794-1-2 LSZH Breakout Cables are the product of choice for indoor and outdoor industrial applications where increased resistance to cyclic flex, compressive forces (crush), impact or higher tensile loads are desirable. In accordance with NRC regulatory guidance, this cable design features a complete absence of PVC and other halogenated polymers which have the potential to create an “acid rain” effect when sprinklers interact with smoke during a fire, thus undermining the potential reliability of other equipment throughout an affected power plant space. LSZH Breakout cables are highly flame retardant and meet nuclear, industrial and NEC general purpose flame and smoke test requirements. Each fiber is protected by 2.4 mm sub-cable which can be “broken-out” from the cable at key equipment junctures. Aramid yarn strength members in each sub-cable allow each fiber to be terminated in a way that protects the fiber from strain during mate-demate cycles, tension or bending at the back of the connector. This is highly desirable for long term connection assembly reliability. Additional aramid yarn strength members are coupled between sub-cables and the semi-pressure extruded outer jacket for better installation strength and for better strain relief when this rugged cable is used with round, military style, hermaphroditic connectors that are often specified for harsh environment connections. The resulting LSZH breakout cable provides the best blend of features for long term fiber optic link reliability within power plant environments. Cable Components 2-Fiber 6-Fiber Mechanical Data PART NUMBER RSBE002242##E RSBE004242##E RSBE006242##E RSBE008242##E RSBE012242##E RSBE018242##E RSBE024242##E FIBER COUNT NOMINAL DIAMETER Inches (mm) WEIGHT lbs/1000ft (kg/km) Installation Long Term Installation Long Term 2 4 6 8 12 18 24 0.34 (8.6) 0.34 (8.6) 0.4 (10.2) 0.46 (11.7) 0.58 (14.8) 0.59 (15) 0.66 (16.8) 50 (75) 50 (75) 73 (108) 95 (141) 153 (228) 138 (206) 183 (273) 300 (1350) 300 (1350) 600 (2700) 600 (2700) 600 (2700) 600 (2700) 600 (2700) 100 (450) 6.8 (17.2) 100 (450) 6.8 (17.2) 200 (900) 8.0 (20.4) 200 (900) 9.2 (23.4) 200 (900) 11.6 (29.6) 200 (900) 11.8 (30) 200 (900) 13.2 (33.60) 3.4 (8.6) 3.4 (8.6) 4.0 (10.2) 4.6 (11.7) 5.8 (14.8) 5.9 (15.0) 6.6 (16.8)  Please specify fiber type when ordering (see next page) TENSION lbs (N) BENDING RADIUS inches (cm) ## - Specify jacket coloring scheme when ordering: 22 = Orange outer jacket, Orange subunits 99 = Yellow outer jacket, yellow subunits. 82 = Black outer jacket, Orange subunits (standard for Multimode) 89 = Black outer jacket, Yellow subunits (standard for singlemode) 8C = Black outer jacket, aqua subunits (Standard for Laser-Link 300) Subunits are printed every 6” with unit number © 2011, AFL, all rights reserved. Revision 2, 6.6.2013 Specifications are subject to change without notice. www.R-SCC.com or (860) 653-8300 5 Indoor/Outdoor, Low Smoke Zero Halogen (LSZH) Breakout Cable Applications Testing Standards • Building Risers • Cable Trays • General Purpose Industrial • Tunnels • Nuclear Power Plants • Outdoor Buried (Duct Installation) IEEE 383 IEEE 1202 OFNR-LS UL-1666 Temperature Range IEC 60332-24 IEC 60754-1 & 2 IEC 61034-2 Operating . . . . . . . . . -40º to + 70ºC Storage . . . . . . . . . . -40º to + 70ºC Installation. . . . . . . . -20º to + 70ºC Optical Performance Information FIBER TYPE Grade-index Multi-mode Fibers (6) 62.5 Giga-Link 300 (5) 50 Giga-Link 600 (L) 50 Laser-Link 300 (OM3) (1) 100/140 Graded Index MM Fiber Step-index Singlemode Fibers (9) Singlemode (K) Futureguide SR-15e Bend Insensitive (AL) Radiation Resistant Singlemode OVERFILLED LAUNCH MINIMUM BANDWIDTH (MHz•km) MAXIMUM ATTENUATION (dB/km) 1300 850 nm nm 1310 nm 1550 nm 1 GIGABIT ETHERNET MINIMUM LINK DISTANCE (meters) 850 nm 1300 nm 850 nm 1300 nm 10GIGABIT ETHERNET MINIMUM LINK DISTANCE (meters) 850 nm 1300 nm (serial) (serial) 3.5 3.5 3.5 5.0 1.2 1.2 1.2 4.0 N/A N/A N/A N/A N/A N/A N/A N/A 200 500 1500* 100 600 500 500 100 300 600 900 N/A 550 600 550 N/A 32 82 300 N/A N/A N/A N/A N/A N/A N/A N/A N/A 0.5 0.5 0.5 0.5 N/A N/A N/A N/A N/A N/A 5,000 5,000 N/A N/A 10,000 10,000 N/A N/A 0.5 0.5 N/A N/A N/A 5,000 N/A 10,000 * 50/125 Laser-Link 300 Effective Modal Bandwidth = 2000 MHz/Km in 850nm window for 10 Gigabit Ethernet Links as measured by Differential Mode Delay (DMD). • Gigabit Ethernet Link Distance are based on modal dispersion constraints. Actual link distance limits may also be constrained by attenuation, depending on customer’s specific loss budget. • Available with specialty fibers also (ex. 200/230, specialty coatings, radiation hardened options). Consult with our engineering specialists to select the best fiber for your applications. Cable Length - Reel Size ITEM Reel Height (inches) Reel Outside Width (inches) Drum Diameter (inches) Reel Weight (lbs) CAPACITY: meters (feet) 2/4 Fiber Breakout 6 Fiber Breakout 8 Fiber Breakout 12 Fiber Breakout 24 Fiber Breakout REEL E 34 20 24 48 REEL F 42 36 23 148 1,300 (4,261) 1,000 (3,280) — 1,000 (3,280) ­ — 2,500 (8,200) 2,500 (8,200) 2,500 (8,200) 1,600 (5,250) 1,300 (4,261) © 2011, AFL, all rights reserved. Revision 1, 3.5.2013 Specifications are subject to change without notice. www.R-SCC.com or (860) 653-8300 6 Low Smoke Zero Halogen Distribution Cable LSZH Distribution cables are economical, multi-purpose cables for running fiber cable between communications closets and equipment rooms, where fibers are terminated in distribution enclosures. Use of flame retardant polyethylene eliminates the use of PVC and other halogenated compounds, consistent with the guidance of NRC Regulatory Guide 1.189. Additionally, this cable family’s OFNR-LS listing makes it suitable for installation in a wide variety of spaces including building risers. Generally this cable will be run in protected raceways and conduit, while more robust cables like the Indoor/ Outdoor Loose Tube cable and Breakout Cables are suited for industrial facility cable tray deployment. The cable offers nuclear facilities an affordable method for supporting in-building data communications links outside of the nuclear island, while using a cable which exceeds telecommunciations industry standards for indoor fiber optic cables and guidance from the NRC. Cable Components Features Applications • Flame Retardant, LSZH jacket • Minimizes use of PVC consistent with NRC Regulatory Guide 1.189 “Fire Protection for Operating Nuclear Power Plants” • OFNR-LS listed • ROHS/REACH SVHC compliant • Routing between communications closets and equipment rooms • Data Center Trunk cabling • LAN distribution / intrabuilding backbones Temperature Range Testing Standards Operating Storage Installation UL1666, UL1685 (OFNR-LS listed) IEEE 383 IEEE 1202 IEC 60332-24 IEC 60754-1&2 IEC 61034-2 -20 C to +70 C -40 C to +70 C -10 to to +60 C Mechanical Data CABLE TYPE QUAD-Link CPC PART NO. LSZH FIBER COUNT TENSION BENDING RADIUS LBS (N) INCHES (CM) NOMINAL DIAMETER WEIGHT INCHES (MM) LBS/ 1000 FT (KG/KM) INSTALLATION LONG TERM INSTALLATION LONG TERM RSUE004482#0E 4 0.189 (4.8) 14 (21) 200 (890) 45 (198) 3.8 (9.6) 1.9 (4.8) RSCE006522#0E 6 0.205 (5.2) 17 ( 26) 200 (890) 45 (198) 4.1 (10.4) 2.1 (5.2) RSCE008542#0E 8 0.213 (5.4) 19 (29) 200 (890) 45 (198) 4.3 (10.8) 2.2 (5.4) RSCE012602#0E 12 0.236 (6.0) 26 (38) 200 (890) 45 (198) 4.8 (12.0) 2.4 (6.0) RSCE018762#0E 18 0.299 (7.6) 39 (58) 300 (1320) 90 (396) 6.0 (15.2) 3.0 (7.6) RSCE024822#0E 24 0.331 (8.4) 50 (75) 300 (1320) 90 (396) 6.5 (16.4) 3.3 (8.2)  Please specify fiber type when ordering (see below) 5 = 50/125 µm multimode GIGA-Link™ 600 7 = 50/125 µm multimode GIGA-Link™ 2000 6 = 62.5/125 µm multimode GIGA-Link™ 300 8 = 62.5/125 µm multimode GIGA-Link™ 1000 9 = 9/125 µm single-mode L = 50/125 µm multimode Laser-Link 300 for 10 Gigabit Ethernet K = Single-mode Futureguide SR-15e Bend Insensitive Contact Customer Service for special fiber types/performance needs. www.R-SCC.com or (860) 653-8300 # Specify jacket color when ordering 2 = Orange (standard for multimode) 8 = Black 9 = Yellow (standard for singlemode) C = Aqua (standard for Laser-Link 300 © 2013, AFL, all rights reserved. PP-10-00001. Revision 0, 5.20.13 Specifications are subject to change without notice. 7 Low Smoke Zero Halogen Distribution Cable (cont.) Specifications CORE SIZE/ FIBER TYPE MAXIMUM ATTENUATION (DB/KM) ISO/ IEC OVERFILL LAUNCH MIN. BANDWIDTH (MHZ•KM) EMBc (MHZ•KM) GIGABIT ETHERNET MIN. LINK DISTANCE (METERS) 850 NM 1300 NM 300 550 10 GIGABIT ETHERNET MIN. LINK DISTANCE (METERS) 850 NM 1300 NM 32 ­— 850 NM 3.5 1300 NM 1.2 1550 NM N/A 850 NM 200 1300 NM 600 N/A (8) 62.5 Giga-Link™ 1000 OM1 (5) 50 Giga-Link™ 600 OM2 3.5 1.2 N/A 350 600 N/A 500 1000 65 — 3.5 1.5 N/A 500 500 N/A 600 600 82 — (L) 50 Laser-Link 300 OM3 3.0 1.2 N/A 1500 500 2000 1000 550 300 — (K) SM Futureguide SR-15e Bend Insensitive (ITU G. 657.A) (9) SM OS2 N/A 0.5 0.5 N/A N/A N/A N/A 5000 N/A 10,000 OS2 N/A 0.5 0.5 N/A N/A N/A N/A 5,000 N/A 10,000 (6) 62.5 Giga-Link™ 300 OM1 Tested to meet or exceed EIA/TIA 568-B3 / Telcordia GR-409-CORE Maximum Cable Length - Reel Size ITEM REEL A REEL B REEL C Reel Height (inches) 16 24 30 REEL D 34 Reel Outside Width (inches) 15 17 15.25 21.25 Drum Diameter (inches) 8 12 12 12 Reel Weight (lbs) 10 23 34 44 4 Fiber Quad-Link 1,000 (3,281) 3,200 (10,500) 5,000 (16,404) — 6 Fiber CPC 1,200 (3,937) 3,800 (12,467) 5,000 (16,404) — 8 Fiber CPC 1,000 (3,281) 3,200 (10,500) 5,000 (16,404) — 12 Fiber CPC 800 (2,625) 2,400 (7,874) 4,000 (13,123) 5,000 (16,404) 18 Fiber CPC (single unit) — 1,300 (4,265) 2,100 ( 6,890) 3,350 (11,000) 24 Fiber CPC (single unit) — 1,000 (3,281) 1,700 ( 5,777) 3,150 (10,335) CAPACITY: METERS (FEET) www.R-SCC.com or (860) 653-8300 © 2013, AFL, all rights reserved. PP-10-00001. Revision 0, 5.20.13 Specifications are subject to change without notice. 8 PVDF Jacketed, Plenum Distribution Cable PVDF Jacketed Distribution Cables are economical, multi-purpose, robust cables for running longer lengths of fiber cable between distribution enclosures throughout an industrial facility. Use of PVDF (fluoropolymer) jacket minimizes the use of PVC, consistent with the guidance of NRC Regulatory Guide 1.189, while providing a high level of resistance to stretching, tear, abrasion, moisture and chemicals. Despite the rugged feel of the cable, it maintains a high degree of flexibility. The cable is plenum listed and can be used in any space requiring flame spread and limited smoke generation requirements including plenum spaces, building risers, cable trays and general purpose industrial installations. Waterblocking strength members and a UV/fungus/moisture resistant outer jacket make the cable suitable for installation in conduit betweeen buildings when the conduit depth or outdoor temperatures prevent cables exposure < -20 deg C. Cable Components Features Testing Standards NFPA 262 (OFNP listed) IEEE 383 IEEE 1202 Temperature Range Operating . . . . . . . . -20ºC to + 70ºC Storage . . . . . . . . . -40ºC to + 70ºC Installation. . . . . . . . 0ºC to + 70ºC • Heat, moisture, chemical resistant fluoropolymer jacket (PVDF) • Minimizes use of PVC consistent with NRC Reg Guide 1.189 “Fire Protecton for Operating Nuclear Power Plants” • Suitable for plenum, riser, cable tray, conduit, or general purpose spaces • Meets ANSI-S-104-696 and Telcordia GR-409 Weatherized Cable water penetration resistance requirements. • ANSI/ICEA S-83-596 (Premises) • Telcordia GR-409 (Plenum: Horizontal and Vertical Backbone) Mechanical Data NOMINAL DIAMETER PART NUMBER CABLE TYPE PVDF Jacketed, Plenum Distribution Cable PLENUM RSKP002482#01 RSKP004482#01 RSKP006552#01 RSKP008602#01 RSKP012702#01 RSKP018782#01 RSKP024852#01  Please specify fiber type when ordering (see below) WEIGHT TENSION LBS (N) FIBER COUNT INCHES (MM) LBS/1000FT (KG/KM) INSTALLATION 2 0.19 (4.8) 18 (27) 150 (660) 4 0.19 (4.8) 18 (27) 150 (660) 6 0.22 (5.5) 22 (33) 150 (660) 8 0.24 (6.0) 26 (38) 150 (660) 12 0.26 (7.0) 34 (50) 150 (660) 18 0.28 (7.8) 40 (60) 300 (1335) 24 0.33 (8.5) 54 (80) 300 (1335) LONG TERM 45 (200) 45 (200) 45 (200) 45 (200) 45 (200) 90 (400) 90 (400) BENDING RADIUS INCHES (CM) INSTALLATION LONG TERM 3.8 (9.6) 1.9 (4.8) 3.8 (96) 1.9 (4.8) 4.3 (11.0) 2.2 (5.5) 4.7 (12.0) 2.4 (6.0) 5.5 (14.0) 2.8 (7.0) 6.1 (15.6) 3.1 (7.8) 6.7 (17.0) 3.4 (8.5) # - Specify outer jacket color when ordering: 2 = Orange outer jacket (standard for multimode) 8 = Black outer jacket 9 = Yellow outer jacket (standard for singlemode) C = Aqua outer jacket (Standard for Laser-Link 300) © 2011, AFL, all rights reserved. Revision 2, 6.13.13 Specifications are subject to change without notice. www.R-SCC.com or (860) 653-8300 9 PVDF Jacketed Plenum Distribution Cable Optical Performance Information FIBER TYPE Grade-index Multi-mode Fibers (6) 62.5 Giga-Link 300 (8) 62.5 Giga-Link 1000 (5) 50 Giga-Link 600 (L) 50 Laser-Link 300 (OM3) (1) 100/140 Graded Index MM Fiber Step-index Singlemode Fibers (9) Singlemode (K) Futureguide SR-15e Bend Insensitive (AL) Radiation Resistant Singlemode MAXIMUM ATTENUATION (dB/km) 1300 850 nm nm 1310 nm 1550 nm OVERFILLED LAUNCH MINIMUM BANDWIDTH (MHz•km) 1 GIGABIT ETHERNET MINIMUM LINK DISTANCE (meters) 850 nm 1300 nm 850 nm 1300 nm 10GIGABIT ETHERNET MINIMUM LINK DISTANCE (meters) 850 nm 1300 nm (serial) (serial) 3.5 3.5 3.5 3.5 5.0 1.2 1.2 1.2 1.2 4.0 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 200 350 500 1500* 100 600 600 500 500 100 300 500 600 900 N/A 550 1,000 600 550 N/A 32 65 82 300 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 0.5 0.5 0.5 0.5 N/A N/A N/A N/A N/A N/A 5,000 5,000 N/A N/A 10,000 10,000 N/A N/A 0.5 0.5 N/A N/A N/A 5,000 N/A 10,000 * 50/125 Laser-Link 300 Effective Modal Bandwidth = 2000 MHz/Km in 850nm window for 10 Gigabit Ethernet Links as measured by Differential Mode Delay (DMD). • Gigabit Ethernet Link Distance are based on modal dispersion constraints. Actual link distance limits may also be constrained by attenuation, depending on customer’s specific loss budget. • Available with specialty fibers (ex. 200/230, specialty coatings, radiation hardened options). Consult with our engineering specialists to select the best fiber for your application. Maximum Cable Length - Reel Size ITEM Reel/Box Height (inches) Reel/Box Outside Width (inches) Drum Diameter (inches) Reel Weight (lbs) CAPACITY: METERS (FEET) 2 Fiber 4 Fiber 6 Fiber 8 Fiber 12 Fiber 18 Fiber 24 Fiber FIBER BOX* 15.13 13.0 8.0 6.0 REEL A 16 15 8 10 REEL B 24 17 12 23 305 (1,000) 305 (1,000) 305 (1,000) — — — — 1,000 (3,281) 1,000 (3,281) — — — — — 3,200 (10,500) 3,200 (10,500) 2,400 (7,874) 2,400 (7,874) 1,300 (4,265) — — REEL C 30 15.25 12 34 5,000 5,000 4,000 4,000 2,100 (16,404) (16,404) (13,123) (13,123) ( 6,890) — — REEL D 34 21.25 12 44 REEL E 34 20 24 48 — — 5,000 (16,404) 5,000 (16,404) 3,900 (12,795) — — — — — — — 1,500 (4,921) 1,500 (4,921) © 2011, AFL, all rights reserved. Revision 1, 7-6.11 Specifications are subject to change without notice. www.R-SCC.com or (860) 653-8300 10 Deployable Cable RSCC-AFL Deployable Cables are ideal for use in installations where extreme environmental conditions are present. Designed to be deployed and retrieved in the field, these cables are highly resistant to damage caused by repetitive impact or harsh conditions. Applications • Field deployment in abusive environments • High traffic areas • Security and sensing applications • Video camera deployments for ALARA purposes Features • Cut resistant, flame retardant polyurethane outer jacket • Highly flexible construction allows for multiple deployments • All aramid strength members • Performance in wide temperature range • High impact and crush resistance • Durable in high traffic areas • Water and UV resistant • Multiple jacket colors available • Harsh environments • Temporary installation of critical communications lines where quick retrieval and re-use is necessary Cable Components Specifications CHARACTERISTIC Cyclic flexing Crush resistance Impact Temperature cycling Temperature Range Operating - 46ºC to + 85ºC TEST PROCEDURE EIA/TIA-455-104 EIA/TIA-455-41 EIA/TIA-455-25 EIA/TIA-455-3 PERFORMANCE 2000 2000 N/cm 200 -46°C to 85°C Installation - 20ºC to + 85ºC Ordering Information NOMINAL DIAMETER PART NUMBER XU00130180G XU00258180G XU00458180G XU00661180G XU01270180G FIBER COUNT 1 2 4 6 12 INCHES (MM) .12 (2.9) .23 (5.8) .23 (5.8) .24 (6.1) .28 (7.0) WEIGHT LBS/1000FT (KG/ KM) 5.4 (8) 21.5 (32) 21.5 (32) 21.5 (33) 31.7 (47) Note: Diameter and weight subject to change without notice Special bandwidth and attenuation specification and/or radiation resistant optical fibers are available. Consult with our application specialists to select the correct fiber and specifications for your application. TENSION LBS (N) INSTALLATION LONG TERM 250 (1112) 66 (290) 325 (1450) 66 (290) 325 (1450) 66 (290) 325 (1450) 66 (290) 394 (1750) 79 (350) corresponding below. 5 = 50/125µm multimode GIGA-Link™ 600 6 = 62.5/125µm multimode GIGA-Link™ 300 * Other fiber types available. BENDING RADIUS INCHES (CM) 1.2 (3.0) 2.3 (5.8) 2.3 (5.8) 2.4 (6.1) 2.8 (7.0) TEMPERATURE RANGE INSTALLAOPERATING TION STORAGE -46°C to 85°C -20°C to 85°C -57°C to 85°C 9 = Single-mode K = SM Futureguide SR-15e Bend Insensitive © 2011, AFL, all rights reserved. Revision 0, 1.12.11 Specifications are subject to change without notice. www.R-SCC.com or (860) 653-8300 11 Fiber Optic Cable Assemblies Fiber Optic Cable Assemblies for the nuclear market utilize the most reliable brands of each connector style on nuclear suitable, LSZH or plenum cables. Zipcord or ruggedized, breakout style cables, can be selected for 2 fiber deployments, depending on the length of the assembly and where it will be routed. For routing of more than 2 fibers between locations, breakout style cables are typically specified to provide greater resistance to impact and crush forces that could be imparted in open trays and ladder racks. Use of pre-terminated assemblies eliminates labor-intensive field termination, yet provides assurance of reliable performance since terminations are performed by trained personnel using factory qualified processes and test procedures. Applications • Head-end termination to a fiber “backbone” • Termination of fiber rack systems • Multi-floor deployment where select fibers are used at each floor • Terminations between equipment racks • Cable trays • General purpose industrial • Nuclear power plants • Splicing “qualified” pigtails to “qualified” cables for safety related applications Features • 2-24 fibers. Each fiber has its own jacket and aramid yarn reinforcement for rugged protection • Flexible for ease of routing • RoHS compliant - Riser, Plenum and LSZH rated cables available • 1 meter standard breakout (other lengths are custom) • Cable type tested to meet or exceed ANSI/ICEA S-83-596/GR-409-CORE • Telcordia GR-326 and TIA 568-C3 compliant connector assemblies • Breakout cables offer superior resistance to crush and impact forces • Cable outer jacket and sub-unit jackets are PVC free • Minimizes use of PVC consistent with US NRC Regulatory Guideline 1.189 “Fire Protection for Operating Nuclear Power Plants” • Cables meet or exceed IEEE 383-1974 flame test requirements Ordering Information UST Connector End A Single-mode ASC = Angle SC AFC = Angle FC USC = Ultra SC UFC = Ultra FC UST = Ultra ST Multimode PSC = SC MM PFC = FC MM PST = ST MM UST Connector End B Single-mode ASC = Angle SC AFC = Angle FC USC = Ultra SC UFC = Ultra FC UST = Ultra ST XXX = No connector ZB 024 Fiber Count Cable Type 001 = 1 002 = 2 004 = 4 008 = 8 006 = 6 012 = 12 024 = 24 PB = Plenum Breakout ZB = LSZH Breakout PS = 3 mm Plenum Simplex LA = 24 mm LSZH Simplex PZ = 2 mm Plenum Zipcord L24Z = 2.4 mm LSZH Zipcord Multimode PSC = SC MM PFC = FC MM PST = ST MM XXX = No connector Q Fiber Type Q = Single-mode ITU-T G.652D X = Single-mode ITU-T G.657A BIF 2 = Multimode 62.5/125 µm OM1 R = Multimode 50/125 µm OM2 L = Multimode 50/125 µm OM3/10G 0015 Cable Length (meters) XXXX (specify length) 0010 = 10 meters Telcordia is a registered trademark of Telcordia Technologies, Inc. © 2013, AFL, all rights reserved. PP-1-00069. Revision 0, 10.8.13 Specifications are subject to change without notice. 12 Connector Specifications PARAMETER CONNECTOR SC Single-mode Assemblies Image Insertion loss (dB) Maximum Typical Return Loss (dB) Minimum Temp Range (°C) Durability Cycles FC ST Ultra Angle Ultra Angle Ultra Angle 0.25 0.2 0.25 0.2 0.25 0.2 0.25 0.2 0.4 0.2 — — -55 dB -65 dB -40 to +85 500 Multimode Assemblies Insertion loss (dB) Maximum 0.5 — Typical 0.25 — Return Loss (dB) Minimum -30 dB — Temp Range (°C) -40 to +85 Durability Cycles 500 Cable Options Simplex/Duplex 900 µm 2.4 mm 3.0 mm -55 dB -65 dB -40 to +85 500 -50 dB — -40 to +85 500 0.5 0.25 0.5 0.25 — — -30 dB — -40 to +85 500 Simplex/Duplex 900 µm 2.4 mm 3.0 mm — — -30 dB — -40 to +85 500 Simplex/Duplex 900 µm 2.4 mm 3.0 mm Telcordia is a registered trademark of Telcordia Technologies, Inc. © 2013, AFL, all rights reserved. PP-1-00069. Revision 0, 10.8.13 Specifications are subject to change without notice. 13 FSM-60S Fusion Splicer Kit The FSM-60S fusion splicer sets the standard for core alignment fusion splicing by incorporating a user-friendly interface with enhanced features to provide the most rugged and reliable fusion splicer in the market today. The new rugged construction adds improved reliability by resisting shock, dust, and rain, and can withstand a 30" drop test. The FSM-60S splices a fiber in 9 seconds and heats a 60mm splice sleeve in 30 seconds, for a total cycle time of only 39 seconds. Automatic tube heater operation, automated monitor image orientation, and battery charge capability during splicer operation provide the end user a productivity tool they can count on. FSM-60S Software included provides the ability to download splice data to a PC for splice data reporting, download splicer operating software via the internet to maintain peak performance, and download video images from the splicer to enhance technical support. Features Detachable Work Table •• Dual-axis core alignment provides the most controlled, most repeatable, lowest loss, permanent connection for optical fibers. •• Splice factory-terminated, singlemode APC pigtails or fusible connectors to fiber optic cables to achieve lowest connection and return losses (recommended for analog video transmission over fiber) •• Imaging algorithms provide time-tested estimate of loss as part of splice process •• Splicer design naturally applies equivalence of 23 kpsi proof test on 125µm clad fibers after splice completion to help ensure long-term mechanical reliability. •• Rugged construction providing shock, dust and moisture resistance •• Dual monitor position with automatic image orientation •• Automatic arc calibration and fiber identification •• User-selectable fiber clamping method – sheath clamp or fiber holders •• Auto-start tube heater feature •• Color LCD display with anti-reflective coating for excellent visibility in bright sunlight •• Simultaneous battery charge and splicer operation •• Long life battery (up to 160 splice/heat cycles per charge) •• Detachable work table incorporated into the transit case •• Data and video download software and splicer upgrade software included; software upgrades through PC application via the internet •• Green friendly – RoHS & WEEE compliant Ordering Information DESCRIPTION FSM-60S Fusion Splicer Kit (with cleaver, battery and cord) Includes: BTR-08 Battery, DCC-14 Battery Charge Cord, CT30A Cleaver, ADC-13 AC Adapter, ACC-14 AC Cord, Spare Electrodes (pair), S60A Sheath Clamp, USB Cable, Splicer Carrying Strap, Quick Reference Guide, Video Instruction Manual, JP-05 Splice Sleeve Cooling Tray, and Transit Case with Carrying Strap AFL NO. S014562 © 2008-2011, AFL, all rights reserved. Revision 3, 5.6.11 Specifications are subject to change without notice. 14 FSM-60S Fusion Splicer Kit Specifications PARAMETER Model Applicable Fibers Cladding Diameter Coating Diameter Fiber Cleave Length Typical Average Splice Loss Splicing Time Arc Calibration Method Splicing Modes Splice Loss Estimate Storage of Splice Result Fiber Display Magnification Viewing Method Operating Condition Mechanical Proof Test Tube Heater Tube Heating Time Protection Sleeve Length Splice/Heat Cycles with Battery Power Supply Terminals Wind Protection Dimensions Weight VALUE FSM-60S Fusion Splicer Single-mode (G.652 & G.657), Multimode (G.651), DS (G.653), NZDS (G.655) 80μm to150μm 100μm to 1,000μm 8 to 16mm with 250μm coating diameter, 16mm with 900μm coating diameter 0.02dB with SM, 0.01dB with MM, 0.04dB with DS, 0.04dB with NZDS, measured by cut-back method relevant to ITU-T and IEC standards Typical 9 seconds with standard single-mode fiber Automatic, real-time and by using results of previous splice when in AUTO mode, manual arc calibration function available 100 preset and user programmable modes Based upon dual camera core alignment data Last 2000 results to be stored in the internal memory X or Y, or both X and Y simultaneously. Front or rear monitor display options with automated image orientation 300X for single X or Y view, or 187X for X and Y view Dual cameras with 4.1 inch TFT color LCD monitor 0 to 5,000m above sea level, 0 to 95%RH and -10 to 50°C respectively 1.96 to 2.25N Built-in tube heater with 30 heating modes; auto-start function Typical 30 seconds with FP-03 sleeve, 35 seconds with FP3 (40), 35-55 seconds with Fujikura micro sleeves 60mm, 40mm, micro Typical 160 cycles with power save functions activated Auto voltage selection from 100 to 240V AC or 10 to 15V DC with ADC-11, 13.2V DC with BTR-08 battery USB 1.1 (USB-B type) for PC communication. Mini-DIN (6-pin) for HJS-02/03 and SH-8 tube heater Maximum wind velocity of 15m/s. (34 mph) 136W x 161D x 143H (mm) / 5.3W x 6.3D x 5.6H (inches) 2.3 kg (5.1 lbs) with AC adapter ADC-11; 2.7kg (5.9 lbs) with BTR-08 battery CT-30 Series Fiber Cleaver The 16-position blade yields 48,000 single-fiber cleaves before requiring replacement, and the built-in scrap collector conveniently stores fiber shards until they can be safely discarded. The CT-30 Cleaver is packaged with three scrap collection options that allow the user to tailor it to their cleaving preferences. Specifications Included with Cleaver: •• AD-30A Adapter Plate (CT30A only) •• FC-02 Fiber Collector •• FDB-02 Scrap Box (small) •• FDB-03 Scrap Box (large) •• SC-01 Side Cover (installed) •• CC-21 Carrying Case •• Hex Wrench (1.5mm) •• Instruction Manual PARAMETER Applicable Fiber Fiber Count Coating Diameter Cladding Diameter Cleave angle capability Blade lifetime Dimensions (W x D x H) Weight VALUE Conventional silica optical fiber Single and up to 12 fiber ribbon 250um to 900um 125um typically <0.5˚ 48,000 fiber cleaves (4,000 12-fiber cleaves) 69mm x 82mm x 41mm (2.7" x 3.2" x 1.6") 180g (0.4 lbs) Ordering Information FIBER HANDLING CLEAVE LENGTH AFL NO. SYSTEM Single Fibers: AD-30A Adapter Plate 900µm: 10-20mm S014080 250-900µm coating, 125µm cladding 250µm: 6-20mm DESCRIPTION APPLICATION CT-30A ACCESSORIES Replacement Blade for CT-30 Series Cleavers S012828 © 2008-2011, AFL, all rights reserved. Revision 3, 5.6.11 Specifications are subject to change without notice. 15 C860 QUAD OTDR and Certification Test Kit Features •• OTDR dynamic range: 22 dB (MM); 26 dB (SM) •• Inspection capable with the DFS1 Digital FiberScope •• Integrated OPM, OLS, and VFL (650 nm) •• OLS sources: LED - 850/1300 nm; Laser - 1310/1550 nm •• Full Auto, Expert, Real-Time OTDR test modes •• >8 hours battery life or AC power •• Touch and Test™ user interface; TRM® reporting software •• Automatic Pass/Fail analysis (TIA/ISO/EN) •• Internal (1000s tests) and USB storage •• Wave ID detect if used with NOYES Wave ID series light sources •• Available in Seven languages Applications •• Tier 1 and Tier 2 testing of premise networks •• Bi-directionally measure loss and length of fiber links •• Perform Pass/Fail Event and Link measurements using OTDR •• Measure loss and length of fiber links •• Certify SM and MM fibers using Pass/Fail criteria of industry standards, applications and user-defined thresholds •• Create professional certification reports C860 with DFS1 Digital FiberScope The NOYES C860 QUAD Certification and OTDR Test Kit from AFL includes one hand-held C840 QUAD OLTS Tester and one C850 QUAD OTDR/OLTS with built-in auto test functionality. With this kit, technicians can troubleshoot and perform both Tier 1 and Tier 2 certification tests of MM and SM fiber networks, store results and create professional test reports. The C850 is both a QUAD Certification Tester and full-featured QUAD OTDR in a compact case with a large transflective touch screen display suitable for both indoor and outdoor operation. The C850 features single-mode and multimode OTDR, Optical Light Sources (OLS), Visual Fault Locator (VFL, 650 nm), and an Optical Power Meter (OPM). As an OTDR, the C850 supports Full Auto, Expert (manual) and Real-Time test modes, simultaneous dual and single wavelength testing, and Event and Pass/Fail analysis based on default or user-defined thresholds. The C840 QUAD Certification Tester includes VFL, OPM, and both single-mode (1310/1550 nm) and multimode (850/1300 nm) OLS. The C840 may be used alone as a traditional power meter or light source to measure fiber loss or as a visual fault locator to find fiber breaks. The C860 kit combines ease of use (Touch and Test™) with multiple functionality and supports visual inspection per IEC 61300-3-35 using the DFS1 Digital FiberScope allowing users the ability to view and document connector end-face images with their OTDR traces and loss results. Thousands of test results may be stored internally or on the supplied USB drive. Test results are transferable via a USB cable or USB drive to a computer for viewing, printing, and analyzing with the supplied Windows® compatible software - TRM® (Test Results Manager). Acceptance reports generated using TRM can include OTDR traces with summary and event information with or without pass/fail indication, Event maps, and end-face images. www.AFLglobal.com or 1-800-321-5298/1-603-528-7780 16 © 2008-2012, AFL, all rights reserved. C860-00-2000 Revision 1H, 2012-06-12 Specifications are subject to change without notice. C860 QUAD OTDR and Certification Test Kit Specifications a OTDR Emitter Type Safety Class Center Wavelengths Wavelength Tolerance Dynamic Range (SNR = 1) Event Dead Zone b Attenuation Dead Zone c Pulse Widths Range Settings Sampling Points Minimum Data Point Spacing Group Index of Refraction (GIR) Distance Uncertainty (m) d Linearity e MULTIMODE SINGLE-MODE POWER METER Laser Class I FDA 21 CFR 1040.10 and 1040.11, IEC 60825-1: 2007-03 850/1300 nm 1310/1550 nm ±20/30 nm ±20/30 nm 22 dB 26 dB 1.5 m 9m 10, 30, 100, 300 ns; 1, 3, 10 µs 250 m to 64 km 250 m to 208 km Calibrated Wavelengths Detector Type Measurement Range Accuracy h Measurement Units Wavelength ID j Set Reference Data Storage Tone Detection Up to 16,000 0.25 m 1.4000 to 1.6000 GENERAL C850 OTDR Test Modes ±(1 + 0.005 % x distance + data point spacing) Trace File Format ±0.05 dB/dB Loss Threshold 0.05 dB Length Measurement Range Loss Resolution 0.01 dB Data Storage Reflectance Accuracy f ±2 dB Wavelength Output Power (nominal) LIGHT SOURCE Available Wavelengths (nom.) Emitter Type Safety Class Output Power Stability (after 15 minutes warm up) Wave ID Transmit Tone Generation C840 TESTER OTDR (Full Auto, Expert, Auto Test, Real-Time), Auto Test, OPM, OLS, VFL, DFS OPM, OLS, VFL, DFS SR-4731 (GR-196-CORE N/A Appendix A, B; SR-4731) 5 km (MM); 200 km (SM) Internal flash memory USB flash drive (2.0) Downloadable from unit directly to PC VISUAL FAULT LOCATOR Emitter Type Safety Class 850, 1300 1310, 1490, 1550, 1625 nm InGaAs 2 mm +6 to -60 dBm ±0.25 dB, dBm, mW Yes (to -47 dBm) Yes Yes Yes (to -47 dBm) Data Storage Capacity Laser Class II FDA 21 CFR 1040.10 and 1040.11, IEC 60825-1: 2007-03 650 ±20 nm 0.8 mW USB Tool Free Adapters Modular cleanable SC/ST/LC Size Weight Operating Temperature Storage Temperature Power Battery Life k, m MM PORT SM PORT 850/1300 nm 1310/1550 nm LED Laser Class I FDA 21 CFR 1040.10 and 1040.11, IEC 60825-1: 2007-03 >-20 dBm, 62.5 µm MM g 0 dBm, 9 µm SM ±0.1 dB over 1 hour ±0.07 dB over 1 hour ±0.15 dB over 8 hours Yes 270 Hz, 330 Hz, 1 KHz, 2 kHz Recharge Time l, m Display Notes: a. All specifications valid at 25 °C unless otherwise specified. b. Typical distance between the two points 1.5 dB down each side of a reflective spike caused by a -45 dB event using 10 ns pulse width. c. Typical distance from event location to point where trace is within 0.5 dB of backscatter caused by a -45 dB event using 10 ns pulse width. d. Does not include GIR uncertainty. e. Typical. f. For a non-saturated event. Internal >1000 fibers Data Transfer to PC 27.4 x 19.3 x 7.1 cm 23 x 11 x 7 cm (10.8 x 7.6 x 2.8 in) (8.8 x 4.3 x 2.8 in) 2.3 kg ( 5 lb) 0.9 kg (2 lb) -10 °C to +50 °C, 0 to 90 % RH (non-condensing) -20 °C to +60 °C, 0 to 90 % RH (non-condensing) Rechargeable Li-Ion or AC power adapter >8 hours continuous testing 4 hours 16.51 cm (6.5 in), color, transflective 9.65 cm (3.8 in), color, transflective g. Output power will be approximately 3 dB less if a 50 µm mandrel-wrapped jumper is used instead of a 62.5 µm mandrel-wrapped jumper. h. Accuracy measured at 25 ºC and -10 dBm per N.I.S.T. standards. j. Automatic wavelength identification and switching when used with NOYES Wave ID Series Light Sources. k. Typical, depending on display brightness. l. Typical, from fully discharged to fully charged state, unit may be operating. m. External battery charger available. www.AFLglobal.com or 1-800-321-5298/1-603-528-7780 17 © 2008-2012, AFL, all rights reserved. C860-00-2000 Revision 1H, 2012-06-12 Specifications are subject to change without notice. C860 QUAD OTDR and Certification Test Kit The C840 and C850 can be used together to perform Tier 1 dual wavelength MM (850/1300 nm) and SM (1310/1550 nm) auto loss tests of one or two fibers in one or both directions as well as measure both loss and length of the fibers and compare to industry standards (TIA/ISO/EN), applications and userdefined thresholds values to certify the fibers. Either unit can be identified as the Main or Remote. The user may test two fibers at two wavelengths bi-directionally and store the results into the main unit. Featuring rich file naming, the Job setup wizard allows the user to define both the cable and fiber end locations, creating easily identifiable trace files, which are managed into Job and Cable folders. The C850 OTDR and C840 Certification tester work with the DFS1 Digital FiberScope. Ordering Information When placing an order, select options as follows: Model, Optical Configuration, Language, and Case. Example: C860 — 100 — LP1 — H1 C860 NNN LLL CC Case (CC) H1 = Hard and soft case with SC-LC cleaning accessories Model C860 Optical Configuration (NNN) 100 = QUAD 850/1300 nm MM and 1310/1550 nm SM Language (LLL) LP1 = Language: English, French, German, Italian, Polish, Portuguese, Spanish Specify Language when ordering a C860 Kit to indicate language preference of OTDR Quick Reference Guide. Specify power cord type (country) when ordering a C860 Kit. One power cord is included with each AC adapter at no charge. Additional power cords may be purchased separately. www.AFLglobal.com or 1-800-321-5298/1-603-528-7780 18 © 2008-2012, AFL, all rights reserved. C860-00-2000 Revision 1H, 2012-06-12 Specifications are subject to change without notice. C860 QUAD OTDR and Certification Test Kit Ordering Information (continued) Each kit includes one compact C850 QUAD OTDR/OLTS, one hand-held C840 QUAD Certification Tester, USB Flash drive, PC software for OTDR trace analysis and certification or OPM loss reporting, (2) AC adapters, switchable test ports adapters, and accessories (see below). The C860 hard carry case kit has room for up to 6 Fiber Rings, jumpers in a jumper carry case, and the DFS1 Digital FiberScope kit (accessory items must be ordered separately). CARRY CASE ADAPTERS CLEANING PRODUCTS OTDR/OLS OPM VFI SC, ST, LC SC, 2.5, 1.25 mm 2.5, 1.25 mm Soft (C850) and hard cases One-Click Cleaner SC/ST/FC, 2.5mm One-Click Cleaner LC, 1.25 mm Cletop - SB white tape AFL NO. C860-100-LP1-H1 Calibration Plans AFL recommends annual calibrations on NOYES Test and Inspection products. Prepaid Cal plans offer two annual calibrations at a discounted price, a convenient calibration expiration email service, express calibration services and access to the NOYES product knowledge base. Cal Plus plans offer the same services as the Cal plans with the addition of a two year extended warranty (three years total coverage). MODEL C860 2 YR CAL PLAN 2 YR CAL PLUS PLAN AFL NO. AFL NO. CAL2-00-C860 CAL2-01-C860 C860—100—LP1—H1 OTDR, Inspection, and Cleaning Accessories ITEM DESCRIPTION C850 QUAD OTDR/Auto Test Certification Tester C840 QUAD Auto Test Certification Tester Adapters OTDR and OLS ports — SC, ST, LC OPM ports — SC, 1.25 and 2.5 mm Universal VFI ports — 1.25 and 2.5 mm Universal Miscellaneous Accessories Mandrels (2) 62.5 µm, 3 mm jacket and (2) 50 µm, 3 mm jacket Stylus pens for touch screen. USB thumb drive, 1G. USB to mini-USB cable Small plastic parts box (2) to store adapter caps and mandrels AC adapter (2), specify country of use Cleaning Accessories Cases (2) One-Click Cleaner SC/ST/FC, 2.5 mm; One-Click Cleaner LC/ MU, 1.25 mm (H2 kit only); Cletop SB white tape Hard transit case — holds C850, C840, and above accessories Soft case for C850 Report Software PC software and user guide DESCRIPTION DFS1 Digital FiberScope PC/UPC Inspection Kit DFS1 Digital FiberScope APC Inspection Kit DFS1 USB Digital Fiber Inspection Kit without Adapters Fiber Ring, 1 fiber, 50/125 µm multimode, 150 m Fiber Ring, 1 fiber, Laser Optimized, 50 µm multimode, 150 m Fiber Ring, 1 fiber, 62.5/125 mm multimode, 150 m AFL NO. DFS1-00-04XU DFS1-00-04XA DFS1-00-04XN FR1-M5-150-x1-x2 a FR1-L5-150-x1-x2 a FR1-M6-150-x1-x2 a Fiber Ring, 1 fiber, single-mode, 150 m Wet Cleaning Kit (shown) for SC/FC/ST/LC connectors. Dry Cleaning Kit One-Click Cleaner SC, ST, FC (500+ cleans) One-Click Cleaner LC/MU (500+ cleans) One-Click Mini-100 SC, ST, FC (100+ cleans) One-Click Mini-100 LC/MU (100+ cleans) One-Click Cleaner Ultra 2.5 SC, ST, FC (enlarged cleaning) Zippered Jumper Carry Case FR1-SM-150-y1-y2 a 8500-20-0900 8500-20-0901 8500-05-0001MZ 8500-05-0002MZ 8500-05-0005MZ 8500-05-0006MZ 8500-05-0007MZ 1400-01-0086PZ Notes: a. When ordering Fiber Rings, specify connector types (x1, x2, y1,y2). FIBER SYSTEM YES S NO NOYES International Sales and Service Contact Information 9001 Available at www.AFLglobal.com/NOYES/Contacts ISO CERTIFIED www.AFLglobal.com or 1-800-321-5298/1-603-528-7780 19 © 2008-2012, AFL, all rights reserved. C860-00-2000 Revision 1H, 2012-06-12 Specifications are subject to change without notice. OFS 300 Optical Microscope Inspect patch cords with NOYES OFS 300 from AFL. Designed for field use, with lab quality optics, the OFS 300 scope delivers a high quality end-face image at 200x magnification. Quickly identify scratches, dirt or other problems normally associated with poor network performance. FACT: A large percentage of network failures are caused by dirty or damaged end-faces on fiber optic connectors. Inspecting jumper end-faces prior to connection is critical to network performance. The OFS 300 scope provides a quality optical inspection tool at an affordable price. Safety: A built-in laser safety filter provides >40 dB IR protection to reduce risk of injury to the eye if accidentally viewing an active fiber.* Features •• Laser safety filter installed •• 200x image size •• 2.5 mm Universal connector Included •• Low battery LED indicator •• Long battery life with 2 AA alkaline •• Rugged, hand-held, easy-to-use •• Tripod mount Applications •• Verify jumper ends are clean prior to connecting to network •• Inspect end-faces for scratches or pits •• Eliminate the most common network fault (bad connectors) The OFS 300 features a universal adapter cap mount that accepts a variety of NOYES thread-on style adapter caps (ordered separately) to ease inspection of many connector style. A momentary power switch located on the top panel keeps one hand free for focusing. Tri-pod mount: For stationary work, the tri-pod mount allows the OFS 300 to attach to any standard camera tri-pod. The OFS 300 offers 60 hours of continuous battery life from standard 2 AA batteries and features an LED indicator, which will flash when batteries require replacement. *Always follow your company’s laser safety procedures and never use an optical microscope to view live fiber optic connectors. Specifications a OPTICAL SPECIFICATIONS Nominal Magnification Adapter Mount Safety Filter 200X Universal, thread-on Schott KG3, >40 dB IR GENERAL SPECIFICATIONS Operating Temperature Storage Temperature Power Battery Life Weight in Use Size (H x W x D) 0°C to +50°C -20°C to +50°C 2 AA batteries >60 hours 0.67 kg (1.5 lb) 13 x 5 x 20 cm (5 x 2 x 8 in) Note: a. All specifications valid at 25°C unless otherwise specified. Ordering Information INCLUDES AFL NO. OFS 300 Inspection Scope, 2 AA batteries, neck strap, 2.5 mm universal adapter cap, and user’s guide OFS 300 NOYES International Sales and Service Contact Information Available at www.AFLglobal.com/NOYES/Contacts www.AFLglobal.com or (800) 321-5298, (603) 528-7780 20 © 2002-2011, AFL, all rights reserved. OFS1-00-2000 Revision U, 2011-07-27 Specifications are subject to change without notice. DFS1 Digital FiberScope The DFS1 Digital FiberScope supports magnified video inspection of optical fiber connector end-faces during fiber optic cable and connector installation and maintenance. The ergonomically designed hand-held unit illuminates fiber end-faces and delivers magnified images via USB port to AFL’s M-series OTDRs (M210, M200, M700) or C-series OTDRs and Certification Testers (C840, C850, C860, C880). FiberScope software displays, labels and stores captured images as part of connector installation and/or maintenance records. DFS1 Digital FiberScope A large adjustment knob permits easy focusing using real-time view. Once focused, a conveniently located trigger button signals the attached display device to capture the image for analysis and archiving. The scope’s ergonomic shape and control locations support comfortable, single-handed operation. Clean connector The DFS1 is powered through the USB port, eliminating the need for an additional battery or AC power supplies. Electronic video inspection eliminates all danger of eye damage from active (lit) fibers carrying either visible or infrared wavelengths. An extensive assortment of adapters supports inspection of a wide range of optical jumper cable connector ferrules and bulkhead adapters. Bulkhead adapter tips are available in multiple lengths as well as 60° angle. Connector adapters are available for PC, UPC or APC polished ferrules in 1.25 mm, 2.5 mm and other diameters. The DFS1 is available in three different kits which provide either PC/UPC adapters, APC adapters or no adapters. Dirty connector DFS1 Digital FiberScope with M210 OTDR Features •• Ergonomic, hand-held design •• Single-handed operation •• 400x magnification •• Fast, easy focus and display capture •• Video output via USB port to M210, M200, M700, C840, C850, C860, C880 or user PC •• Powered from USB; no batteries required •• Extensive assortment of interchangeable fiber connector and bulkhead adapter tips •• Adapter tips easily changed; no tools required •• Use AFL SimpleView PC software with DFS1 to inspect connectors using a laptop PC AFL SimpleView™ Fiber Inspection Software is an application, which permits the DFS1 Digital FiberScope to be used with Windows® XP or Windows® 7 computers. AFL SimpleView software displays a live, high-resolution video image of the endface of an optical fiber on the PC’s display. SimpleView software is a free download www.AFLglobal.com. Applications •• Ideal for telco, broadband and enterprise applications •• Optical connector and bulkhead adapter inspection •• Display and analyze fiber end-face quality on C- and M-series •• Visually inspect fiber end-faces for damage or contamination impairing optical transmission •• Generate installation inspection records, associating captured digital photo with fiber ID www.AFLglobal.com or (800) 321-5298, (603) 528-7780 21 © 2011-2012, AFL, all rights reserved. DFS1-00-2000 Revision 1C, 2012-01-30 Specifications are subject to change without notice. DFS1 Digital FiberScope Specifications DFS1 Digital FiberScope with M700 OTDR a PARAMETERS VALUE 400X Magnification ~400 µm x 300 µm Field of View 0.5 μm detectable Resolution 0°C to 50°C Operating Temperature -20°C to 70°C Storage Temperature Manual adjustment, 2 mm max travel Focus 35 mm diameter x 175 mm length (without tip) 200 g Dimensions Weight Blue LED USB port of M-series OTDRs or C-series OTDRS and Certification Testers Light Source Power Supply Note: a. All specifications valid at 23°C ±2°C (73.4°F ±3.6°F) unless otherwise specified. Ordering Information DFS1 Digital FiberScope Kit The DFS1 is available in three different kits which provide either PC/UPC adapters, APC adapters, or no adapters. All kits include soft carry case, a storage box to hold up to six adapter tips, FiberScope display software update for M-series OTDRs (M200, M700) or C-series OTDRs and Certification Testers (C840, C850, C860, C880), and a quick reference guide. DESCRIPTION DFS1 Digital FiberScope PC/UPC Inspection Kit includes: (1) DFS1-00-04X0MR DFS1 USB Digital FiberScope (1) DFS1-00-0001MR Universal 1.25 mm male PC adapter tip (1) DFS1-00-0002MR Universal 2.5 mm male PC adapter tip (1) DFS1-00-0003MR SC and FC female bulkhead adapter tip (1) DFS1-00-0004MR LC female bulkhead adapter tip (1) DFS1-04-0001MZ soft carry case for scope and adapters (1) 8500-05-0001MZ One-Click Cleaner SC, ST, FC (1) 8500-05-0002MZ One-Click Cleaner LC/MU (1) 1400-01-0093MZ 6-compartment adapter tip storage box (1) Digital FiberScope display software update for M200, M700, C840, C850, C860, or C880 DFS1 Digital FiberScope APC Inspection Kit includes: (1) DFS1-00-04X0MR DFS1 USB Digital FiberScope (1) DFS1-01-0002MR Universal 2.5 mm male APC adapter tip (1) DFS1-01-0003MR SC/APC and FC/APC bulkhead adapter tip (1) DFS1-01-0011MR SC/APC bulkhead adapter tip (1) DFS1-04-0001MZ soft carry case for scope and adapters (1) 8500-05-0001MZ One-Click Cleaner SC, ST, FC (1) 1400-01-0093MZ 6-compartment adapter tip storage box (1) Digital FiberScope display software update for M200, M700, C840, C850, C860, or C880 DFS1 USB Digital Fiber Inspection Kit without Adapters includes: (1) DFS1-00-004X0MR DFS1 USB Digital FiberScope (1) Soft carry case for scope and adapters (1) 6-compartment adapter tip box (1) Digital FiberScope display software update for M200, M700, C840, C850, C860, or C880 www.AFLglobal.com or (800) 321-5298, (603) 528-7780 22 AFL NO. DFS1-00-04XU DFS1-00-04XA DFS1-00-04XN © 2011-2012, AFL, all rights reserved. DFS1-00-2000 Revision 1C, 2012-01-30 Specifications are subject to change without notice. DFS1 Digital FiberScope Ordering Information (continued) DFS1 Accessories DFS1-00-0001MR DESCRIPTION Soft carry case for DFS1 Digital FiberScope and adapters AFL NO. DFS1-04-0001MZ 6-compartment adapter tip storage box 1400-01-0093MZ 11-compartment adapter tip storage box 1400-01-0094MZ One-Click Cleaner SC, ST, FC 8500-05-0001MZ One-Click Cleaner LC/MU 8500-05-0002MZ AFL SimpleView PC viewer software Free download from www.AFLglobal.com DFS1 Adapter Tips DFS1-00-0002MR DFS1-00-0004MR DFS1-00-0013MR The following table identifies commonly required adapter tips. Other adapter tips available. Please consult the factory for additional adapter tips and prices. DESCRIPTION PC FERRULE CONNECTOR ADAPTER TIPS AFL NO. Universal 1.25 mm tip for PC ferrule connector Universal 2.5 mm tip for PC ferrule connector Universal 2.0 mm tip for PC ferrule connector Slim 1.6 mm tip for PC ferrule (termini) Slim 1.25 mm probe tip for LuxCis and termini Slim 2.5 mm PC ferrule tip for ELIO and termini Tip for ELIO 1.25 mm ferrule connector SC/PC AND FC/PC BULKHEAD ADAPTER TIPS DFS1-00-0001MR DFS1-00-0002MR DFS1-00-0005MR DFS1-00-0006MR DFS1-00-0038MR DFS1-00-0039MR DFS1-00-0008MR Tip for SC/PC and FC/PC bulkhead adapter Short extended tip for SC/PC and FC/PC bulkhead adapter Medium extended tip for SC/PC and FC/PC bulkhead adapter Long extended tip for SC/PC and FC/PC bulkhead adapter 60° angled tip for SC/PC and FC/PC bulkhead adapter 60º angled tip for SC/PC bulkhead adapter ST/PC BULKHEAD ADAPTER TIPS DFS1-00-0003MR DFS1-00-0010MR DFS1-00-0011MR DFS1-00-0012MR DFS1-00-0013MR DFS1-00-0040MR Tip for ST/PC bulkhead adapter Short extended tip for ST/PC bulkhead adapter Medium extended tip for ST/PC bulkhead adapter Long extended tip for ST/PC bulkhead adapter 60° angled tip for ST/PC bulkhead adapter LC/PC BULKHEAD ADAPTER TIPS DFS1-00-0014MR DFS1-00-0015MR DFS1-00-0016MR DFS1-00-0017MR DFS1-00-0018MR Tip for LC/PC bulkhead adapter Short extended tip for LC/PC bulkhead adapter Medium extended tip for LC/PC bulkhead adapter Long extended tip for LC/PC bulkhead adapter 60° angled tip for LC/PC bulkhead adapter DFS1-00-0004MR DFS1-00-0019MR DFS1-00-0020MR DFS1-00-0021MR DFS1-00-0022MR www.AFLglobal.com or (800) 321-5298, (603) 528-7780 23 © 2011-2012, AFL, all rights reserved. DFS1-00-2000 Revision 1C, 2012-01-30 Specifications are subject to change without notice. DFS1 Digital FiberScope Ordering Information (continued) DESCRIPTION E2000/PC BULKHEAD ADAPTER TIPS AFL NO. Short extended tip for E2000/PC bulkhead adapter Medium extended tip for E2000/PC bulkhead adapter Long extended tip for E2000/PC bulkhead adapter MU/PC BULKHEAD ADAPTER TIPS DFS1-00-0023MR DFS1-00-0024MR DFS1-00-0025MR Tip for MU/PC bulkhead adapter Short extended tip for MU/PC bulkhead adapter Medium extended tip for MU/PC bulkhead adapter Long extended tip for MU/PC bulkhead adapter 60° angled tip for MU/PC bulkhead adapter MTP/PC MULTI-FIBER ADAPTER TIPS (FERRULE & BULKHEAD) DFS1-00-0026MR DFS1-00-0027MR DFS1-00-0028MR DFS1-00-0029MR DFS1-00-0030MR MTP/PC bulkhead adapter extended tip; includes base plus MTP/PC front end tip. Test ferrules using adapter tip with bulkhead adapter. Front end tip for MTP/PC ferrule and bulkhead adapter MTP/PC and MTP/APC bulkhead adapter extended tip kit; includes base plus MTP/PC and MTP/APC front end tips. Test ferrules using adapter tip with bulkhead adapter. MISCELLANEOUS PC BULKHEAD ADAPTER TIPS DFS1-00-0037MR Tip for LEMO 2.0 mm bulkhead adapter Tip for LX.5/PC bulkhead adapter Tip for 2.0 mm termini bulkhead adapter Tip for 1.6 mm termini bulkhead adapter Tip for ELIO 1.25 mm bulkhead adapter APC TIPS DFS1-00-0031MR DFS1-00-0032MR DFS1-00-0033MR DFS1-00-0034MR DFS1-00-0036MR Universal 1.25 mm tip for APC ferrule connector Universal 2.5 mm tip for APC ferrule connector Tip for SC/APC and FC/APC bulkhead adapter Tip for SC/APC bulkhead adapter Tip for LC/APC bulkhead adapter DFS1-01-0001MR DFS1-01-0002MR DFS1-01-0003MR DFS1-01-0011MR DFS1-01-0004MR Short extended tip for SC/APC bulkhead adapter 60° angled tip for SC/APC bulkhead adapter Tip for E2000/APC bulkhead adapter Tip for LX.5/APC bulkhead adapter MTP/APC bulkhead adapter extended tip kit; includes base plus MTP/APC front end tip. Test ferrules using adapter tip with bulkhead adapter. Front end tip for MTP/APC ferrule and bulkhead adapter DFS1-01-0005MR DFS1-01-0006MR DFS1-01-0008MR DFS1-01-0009MR DFS1-01-0010MR DFS1-00-0041MR DFS1-00-0042MR DFS1-01-0012MR NOYES International Sales and Service Contact Information Available at www.AFLglobal.com/NOYES/Contacts www.AFLglobal.com or (800) 321-5298, (603) 528-7780 24 © 2011-2012, AFL, all rights reserved. DFS1-00-2000 Revision 1C, 2012-01-30 Specifications are subject to change without notice. VFI2 and HiLite Visual Fault Identifiers The NOYES VFI2 and HiLite visible red laser sources from AFL are designed to troubleshoot faults on fiber optic cables. Light generated by these units will escape from sharp bends and breaks in jacketed or bare fibers, as well as poorly-mated connectors. They can quickly identify faults in fiber optic jumper cables, distribution frames, patch panels, and splice trays. The HiLite and VFI2 are an excellent complement to an OTDR because they can locate faults inside the OTDR’s dead-zone. Other applications include end-to-end continuity checks, identifying connectors in patch panels and fibers during splicing operations. VFI2 Visual Fault Identifier Trace cables in messy or undocumented setups. A VFI unit provides a quick means of finding the “other end” from amongst cluttered cables. Simply connect the VFI to one end and look for the visual red light transmitted out the opposite connector. Fiber Coupled Lasers for Best Test Results: NOYES VFI2 units deliver 1 mW of output power into 9/125 single-mode fiber to ensure long range and exceptional brightness for locating defects in single-mode and multimode fibers. The VFI2 and HiLite units use a threaded connector adapter interface to support adapter removal for connector cleaning and field changing of adapter styles. The 2.5 mm adapter accepts PC and angled connectors FC, SC, ST, etc. and the 1.25 mm adapter accepts LC and MU connectors. A Visible Fault Indicator (VFI) is an essential tool for fiber technicians. VFI2 Visual Fault Identifier Features •• Visible red laser source, 650 nm •• High power, 1 mW into 9/125 single-mode fiber •• Compact size •• Universal connector interface for quick connection •• 2.5 mm Universal adapter included •• 1.25 mm Universal adapter available Applications •• Identify fiber faults inside OTDR deadzone •• Identify sharp bends or breaks in fibers •• Identify poorly mated connectors •• Verify AFL FAST Connector Installation Ordering Information VFI2 Models DESCRIPTION VFI2 visual fault identifier with 2.5 mm adapter AFL NO. VFI2-00-0900PR VFI2 visual fault identifier with 2.5 mm and 1.25 mm adapters VFI2-01-0900PR HiLite Models DESCRIPTION AFL NO. HiLite visual fault identifier with 2.5 mm adapter VFI3-00-0900PR HiLite visual fault identifier with 2.5 mm and 1.25 mm adapters VFI3-01-0900PR Adapters DESCRIPTION 2.5 mm Universal adapter b with captivated sleeve AFL NO. 2900-50-0007MR 1.25 mm Universal adapter c with captivated sleeve 2900-50-0010MR Notes: a. All specifications valid at 25°C unless otherwise specified. b. 2.5 mm Universal adapter accepts SC, FC, ST, E2000 ferrules. c. 1.25 mm Universal adapter accepts LC, MU ferrules. www.AFLglobal.com or (800) 321-5298, (603) 528-7780 25 © 2002-2012, AFL, all rights reserved. VFI3-00-2000 Revision N, 2012-01-27 Specifications are subject to change without notice. SMLP5-5 Test Kit The SMLP5-5 Test Kit with Wave ID, Set Reference, and Data Storage combines the OPM5-2D optical power meter and OLS4 integrated LED and laser light source and is ideally suited for testing fiber optic networks with hybrid (single-mode and multimode) cables. The OLS4 features 850/1300 nm LED output from a multimode output port and 1310/1550 nm laser output from a single-mode output port. Each wavelength may be transmitted individually at CW or with user selectable modulated Tone(SM output). Also, each wavelength may be transmitted with Wave ID. Both output ports are equipped with UCI based removable adapters to allow the output connectors to be inspected and cleaned. The OPM5-2D is a full-featured, hand-held optical power meter designed for measuring optical power in premise, telco, or broadband networks and for performing insertion loss measurements on multimode or single-mode fiber optic links. The standard Wave ID feature (when used with NOYES OLS series light sources) automatically detects and sets the wavelength(s), preventing setup and measurement errors. It significantly increases efficiency and reduces technician errors—and saves testing time—by eliminating the need to test each wavelength individually. The OPM5-2D stores optical references for each calibrated wavelength and offers multiple test tone detection for fiber identification. Features (SMLP5-5 Test Kit) •• Wave ID reduces test time •• Hand-held, rugged, lightweight •• Cost-effective, easy-to-use •• N.I.S.T traceable •• OLS4 Quad Light Source •• Dual or single Wave ID, CW, Tone •• Industry standard 2 kHz test Tone •• 50 µm and 62.5 µm mandrels •• OPM5-2D Optical Power Meter •• File management system organizes stored test data •• Storage capability >500 fibers •• USB port for download of stored data •• TRM™ PC Reporting Tool (Windows® compatible) •• Apply certification rules to test results •• Create professional test reports •• Archive test results Data Storage of Test Results The OPM5-2D File Management system allows technicians to organize test results into multiple files and transfer stored results via USB to a PC for analyzing, generating reports, and printing. The supplied powerful PC Analysis and Reporting Tool (TRM® - Test Results Management software) allows users to apply industry standards based rules to test results and create comprehensive certification reports. Users can generate network Pass/Fail results demonstrating compliance to industry standards and illustrate headroom. TRM is a Windows® compatible software. The SMLP5-5 test kit is fully N.I.S.T. traceable. Applications •• Certify multimode and single-mode links per TIA/EIA standards •• Fiber identification prior to splicing •• Passive Optical Networks (PON) testing •• Save test data for report generation with NOYES TRM Software www.AFLglobal.com or (800) 321-5298, (603) 528-7780 26 © 2002-2012, AFL, all rights reserved. SMLP-55-2001 Revision F, 2012-07-11 Specifications are subject to change without notice. SMLP5-5 Test Kit OLS4 Light Source Specifications OPTICAL Wavelength Emitter Type Spectral Width Output Power Output Stability GENERAL Power Battery Life Available Adapters Operating Temperature Storage Temperature Size (H x W x D) Weight MM OPTICAL PORT OPM5-2D Specifications a SM OPTICAL PORT 850 1300 1310 1550 ±30 nm -10/+50 nm ±20 nm ±20 nm LED Laser Class I FDA 21 CFR 1040.10 and 1040.11, IEC 60825-1: 2007-03 40 nm (typ) 120 nm (typ) 5 nm (max) 5 nm (max) >-20 dBm, 0 dBm, 62.5 µm multimode b 9 µm single-mode ±0.1 dB over 8 hours ±0.05 dB over 1 hour (after 5-minute warm-up) (after 15-minute warm-up) ±0.1 dB over 8 hours (after 15-minute warm-up) OPTICAL OPM5-2D Calibrated Wavelengths 850, 1300, 1310, 1490, 1550 nm Detector Type Germanium (Ge) Measurement Range +6 to -60 dBm Tone Detect Range +6 to -50 dBm +6 to -45 dBm for 850 nm +6 to -50 dBm +6 to -45 dBm for 850 nm ±0.25 dB 0.01 dB dB, dBm, μW Wavelength ID Range Accuracy c Resolution Measurement Units GENERAL Power Battery Life Operating Temperature Storage Temperature Size (H x W x D) Weight 2 AA batteries, optional AC adapter Typical 30 hours, Typical 72 hours, minimum 20 hours minimum 40 hours SC FC, ST, LC -10°C to 50°C, 90 % RH (non-condensing) -30°C to 60°C, 90 % RH (non-condensing) 14.0 x 8.1 x 3.8 cm (5.5 x 3.2 x 1.5 in) 0.29 kg (0.65 lb) a 2 AA batteries, optional AC adapter 300 hours -10°C to 50°C, 90 % RH (non-condensing) -30°C to 60°C, 90 % RH (non-condensing) 14.0 x 8.1 x 3.8 cm (5.5 x 3.2 x 1.5 in) 0.26 kg (0.58 lb) Notes: a. All specifications valid at 25°C unless otherwise specified. b. Output power will be approximately 3 dB less if a 50 µm mandrel-wrapped jumper is used instead of a 62.5 µm mandrel-wrapped jumper. c. Accuracy measured at 25ºC and -10 dBm per N.I.S.T. standards. Ordering Information Test jumpers and connector adapters are required for operation (purchased separately). Test jumpers with a variety of connector styles and fiber types and adapter caps for most common connectors may be purchased from AFL. INCLUDES OLS4 optical light source, OPM5-2D optical power meter, AA batteries, protective rubber boots, adapter cap, USB cable, PC reporting tool - TRM® (Windows® compatible), 50 and 62.5 µm mandrels, and carry case AFL NO. SMLP5-5 Calibration Plans AFL recommends annual calibrations on NOYES Test and Inspection products. Prepaid Cal plans offer two annual calibrations at a discounted price, a convenient calibration expiration email service, express calibration services and access to the NOYES product knowledge base. Cal Plus plans offer the same services as the Cal plans with the addition of a two year extended warranty (three years total coverage). MODEL SMLP5-5 2 YR CAL PLAN 2 YR CAL PLUS PLAN AFL NO. AFL NO. CAL2-00-SMLP5-5 CAL2-01-SMLP5-5 NOYES International Sales and Service Contact Information Available at www.AFLglobal.com/NOYES/Contacts www.AFLglobal.com or (800) 321-5298, (603) 528-7780 27 © 2002-2012, AFL, all rights reserved. SMLP-55-2001 Revision F, 2012-07-11 Specifications are subject to change without notice. M210 Multifunction Micro OTDR Test, Troubleshoot and Document Single-mode and Multimode Fiber Networks Features •• 30 dB dynamic range single-mode •• 16-hour battery life •• Remote display capable •• Touch and Test™ intuitive user interface •• New faster processor •• Crisp bright display for indoor/outdoor viewing •• Integrated OPM standard; integrated VFL standard •• Inspection capable with DFS1 Digital FiberScope •• Rugged, hand-held, lightweight (<1 kg) •• Prepaid Calibration plans, Cal and Cal Plus (see next page) Test Modes •• Full Auto OTDR – Normal (point-to-point) fiber cable construction M210 OTDR with DFS1 Digital FiberScope testing and fault location •• Expert OTDR – Full function OTDR for experienced users includes Auto and Auto-Once setup •• Real-Time OTDR – Fault location, splice verification •• Optical Power Meter – Measure optical power or fiber loss •• Visual Fault Locator – Red laser for fiber bend and break location Languages supported •• English •• French •• German •• Italian •• Spanish •• Polish •• Portuguese The NOYES M210 is the only inspection ready QUAD OTDR that combines OTDR, OPM and VFL capability with a proven, easy-to-use and easy-to-learn user interface. The M210 is the latest addition to the M200 family of OTDRs. Like other members of the M200 family, the M210 offers the intuitive Touch and Test user interface in a rugged, lightweight, easy-to-hold package ready for field use. The M210 features a more powerful processing engine, a higher resolution display and, for the first time in an OTDR of its size, an integrated Optical Power Meter. Touch and Test simplifies the M210 user experience, minimizes human errors and reduces training time by providing one-touch access to the Full-Auto, Expert and Real-Time OTDR test modes, OPM measurement mode as well as the Results Management and Job Creation menus. The M210 allows setting Pass/Fail thresholds to industry standard TIA/ISO or user-values and will automatically alert users of failing fibers. Touch and Test enables both experts and novices alike to complete jobs more accurately and in less time. www.AFLglobal.com or (800) 321-5298, (603) 528-7780 28 © 2012, AFL, all rights reserved. M210-00-2000 Revision 1B, 2012-06-18 Specifications are subject to change without notice. M210 Multifunction Micro OTDR M210 Models and Included Adapters WAVELENGTHS (nm) 850 1300 1310 OPM PORT ADAPTERS AFL BASE MODEL NO. SC, FC SC, 2.5 mm Universal M210-20 26/26 SC, ST SC, 2.5 mm Universal M210-22 26/26/30/30 SC, FC, ST SC, 2.5 mm Universal M210-25 DYNAMIC OTDR PORT RANGE (dB) ADAPTERS 1550 30/30 All M210 OTDRs include a USB flash drive, an AC adapter, UCI switchable adapters for OTDR and OPM ports, trace analysis and documentation software and a quick reference guide. Ordering Information DESCRIPTION M210 QUAD Certification Kit (Tier 1 and 2): M210 QUAD, OLS4, DFS1* in hard case M210 QUAD Test and Inspection Kit (Tier 2): M210 QUAD, DFS1* in hard case AFL NO. M210-25K-01-HC2 M210-25K-01-HC1 * When ordering, specify DFS1 model. The DFS1 FiberScope kit is available as either PC/UPC inspection kit (DFS1-00-04XU model) or APC inspection kit (DFS1-004XA model). M210 OTDR, SM (1310/1550), OPM, VFL in hard case M210 OTDR, MM (850/1300) OPM, VFL in hard case M210-20U-01-HC M210-22U-01-HC M210 OTDR, QUAD (850/1300/1310/1550), OPM, VFL in hard case M210 OTDR, SM (1310/1550) OPM, VFL in soft case M210 OTDR, MM (850/1300) OPM, VFL in soft case M210 OTDR, QUAD (850/1300/1310/1550), OPM, VFL in soft case M210-25U-01-HC M210-20U-01 M210-22U-01 M210-25U-01 M210 NN U LL When ordering, select options as follows: Optical Configuration (NN), (U) for UPC connection and Language (LL). Add (HC) only if ordering the hard case option. Example: M210-25U-01-HC -> This model number indicates M210 QUAD with the English/European language pack in the optional hard case. HC Hard Case option (HC) Optical Configuration (NN) 20 = 1310/1550 nm SM 22 = 850/1300 nm MM 25 = 850/1300 nm MM and 1310/1550 nm SM (Select (HC) only if ordering hard case option) Language (LL) 01 = English, French, German, Italian, Polish, Portuguese, Spanish OTDR port ferrule (U = UPC) *Specify Language for OTDR Quick Reference Guide Calibration Plans M210 OTDR AND/OR KIT MODEL M210-25K-01-HC1 M210-25K-01-HC2 M210-20U-01-HC M210-22U-01-HC M210-25U-01-HC M210-20U-01 M210-22U-01 M210-25U-01 2 YR CAL PLAN AFL NO. CAL2-00-M210-25K-HC1 CAL2-00-M210-25K-HC2 CAL2-00-M210-20 CAL2-00-M210-22 CAL2-00-M210-25 CAL2-00-M210-20 CAL2-00-M210-22 CAL2-00-M210-25 2 YR CAL PLUS PLAN AFL NO. CAL2-01-M210-25K-HC1 CAL2-01-M210-25K-HC2 CAL2-01-M210-20 CAL2-01-M210-22 CAL2-01-M210-25 CAL2-01-M210-20 CAL2-01-M210-22 CAL2-01-M210-25 AFL recommends annual calibrations on NOYES Test and Inspection products. Prepaid Cal plans offer two annual calibrations at a discounted price, a convenient calibration expiration email service, express calibration services and access to the NOYES product knowledge base. Cal Plus plans offer the same services as the Cal plans with the addition of a two year extended warranty (three years total coverage). NOYES International Sales and Service Contact Information Available at www.AFLglobal.com/NOYES/Contacts www.AFLglobal.com or (800) 321-5298, (603) 528-7780 29 © 2012, AFL, all rights reserved. M210-00-2000 Revision 1B, 2012-06-18 Specifications are subject to change without notice. One-Click Cleaner Series With Innovative Push-to-Clean Design The One-Click Cleaner is an easy-to-use option for cleaning connectors on jumpers and in adapters. Simply insert the One-Click Cleaner into an adapter and push until an audible “click” is heard. The One-Click Cleaner uses the mechanical push action to advance an optical grade cleaning tape while the cleaning tip is rotated to ensure the fiber end-face is effectively, but gently cleaned. The One-Click Cleaner is a must-have for field technicians. Small enough to fit in a shirt pocket and a great addition to cleaning kits. Save your wrist – no more twist! MU/LC Mini-100 SC/ST/FC ODC Mini-500 Compact One-Click Cleaner Mini: Offering the same technology and performance as the original, the One-Click Cleaner is now available in a smaller, more compact size, which allows for cleaning of connectors in tighter places. Its smaller size also makes it a great addition to test kits and cleaning kits. The One-Click Mini that is offered by AFL as a low cost solution with 100+ cleans per unit is now also available with same 500+ cleans per unit as the standard One-Click. The One-Click Mini is an effective, easy-to-use cleaning solution for SC, ST, FC, LC, MU and TFOCA connectors. Rugged ODC® Version: With the increasing demand of Outdoor Connector (ODC) plug and socket styles, the ODC One-Click Cleaner, which cleans the ferrules in ODC plug, socket and 1.25 mm ferrules, is an essential cleaning tool for WiMax Base Station, Fiber-to-the-Antenna, Broadcasting and Surveillance Video technicians. One-Click Ultra Cleaner 2.5: The new One-Click Ultra Cleaner 2.5 has an enlarged cleaning area to clean more of the connector end-face. The One-Click Ultra Cleaner 2.5 cleans up to a 2 mm diameter area of the connector end-face. The One-Click Ultra Cleaner is a superior cleaner for SC, ST, and FC connectors. One-Click Cleaner D-LC (Duplex LC): Reduce cleaning time with the new One-Click Cleaner D-LC. Offering the same performance and easy-to-use one-click technology as the original, the One-Click Cleaner D-LC cuts cleaning time in half by effectively cleaning both LC connectors of a duplex LC at one time. 500+ duplex LC cleans per cleaner (1000+ LC connector cleans). Features D-LC 2.5 Ultra •• Cleans connectors on jumpers and in adapters; low cost per clean •• Effective on a variety of contaminates including dust and oils •• Ergonomic, comfortable design with single action cleaning •• Automatic advance ensures each clean is performed with fresh cleaning tape •• Compliant with EU/95/2002/EC Directive (RoHS) •• Available with enlarged cleaning area up to 2 mm •• Duplex LC version available www.AFLglobal.com or (800) 321-5298, (603) 528-7780 30 © 2008-2012, AFL, all rights reserved. 8500-05-2000 Revision 1F, 2.16.12 Specifications are subject to change without notice. One-Click Cleaner Series Illustration of cleaning procedure for SC connectors SC Adapter Clean End-face One-Click Cleaner SC Cleaning of Dust (single-mode 10/125 fiber) Cleaning of Oil (single-mode 10/125 fiber) Before Cleaning After Cleaning Before Cleaning After Cleaning Ordering Information MODEL One-Click SC, ST, FC DESCRIPTION One-Click Cleaner SC, ST, FC (500 cleans) LENGTH 172 mm (6.88 in) AFL NO. BASE 17.5 x 17.5 mm (0.7 x 0.7 in) 8500-05-0001MZ One-Click LC/MU One-Click Cleaner LC/MU (500 cleans) 172 mm (6.88 in) 17.5 x 17.5 mm (0.7 x 0.7 in) 8500-05-0002MZ One-Click ODC One-Click Mini-100 SC, ST, FC One-Click Cleaner ODC (outdoor connector, 500 cleans) One-Click Cleaner Mini-100 SC, ST, FC (100 cleans) 172 mm (6.88 in) 17.5 x 17.5 mm (0.7 x 0.7 in) 8500-05-0004MZ 120.65 mm (4.75 in) 17.5 x 30.2 mm(0.7 x 1.2 in) 8500-05-0005MZ One-Click Mini-100 LC/MU One-Click Cleaner Mini-100 LC/MU (100 cleans) 120.65 mm (4.75 in) 17.5 x 30.2 mm(0.7 x 1.2 in) 8500-05-0006MZ 120.65 mm (4.75 in) 17.5 x 30.2 mm(0.7 x 1.2 in) 8500-05-0009MZ 120.65 mm (4.75 in) 17.5 x 30.2 mm(0.7 x 1.2 in) 8500-05-0010MZ One-Click Mini-500 SC, ST, FC One-Click Cleaner Mini-500 SC, ST, FC (500 cleans) One-Click Cleaner Mini-500 LC/MU (500 cleans) One-Click Mini-500 LC/MU One-Click Ultra Cleaner 2.5 One-Click D-LC One-Click Ultra Cleaner 2.5 SC, ST, FC 203.2 mm (8 in) (enlarged cleaning area, 500 cleans) One-Click Ultra Cleaner D-LC (Duplex LC, 500 cleans x 2) 195 mm (7.7 in) 22.2 x 33.3 mm (0.8 x 1.3 in) 8500-05-0007MZ 18 x 30 mm (0.7 x 1.2 in) 8500-05-0008MZ NOYES International Sales and Service Contact Information Available at www.AFLglobal.com/NOYES/Contacts www.AFLglobal.com or (800) 321-5298, (603) 528-7780 31 © 2008-2012, AFL, all rights reserved. 8500-05-2000 Revision 1F, 2.16.12 Specifications are subject to change without notice. Cletop Cassette Cleaner Series The Cletop connector cleaner is a rugged palm-sized cleaner that offers exceptional performance with a proven track record. The choice of many leading manufacturers and telecom carries worldwide for nearly 20 years – Cletop is a name you can rely on. Why Clean Fiber Connectors? Cletop -S Series •• Pits and scratches are often caused by dirt •• Dust, dirt, oils, etc. ,are everywhere and will migrate to exposed connector end-faces •• Dirty connectors attenuate signal levels and can increase digital bit error rates •• Always clean both connectors when mating / unmating to avoid contamination transfer Cletop Cassette Cleaner Options Cletop Series •• Cletop Series – Original version (proven reliability) •• Cletop -S Series – Second generation cleaner offering the same Cletop cleaning performance with “Drop-in” replacement tape cartridge and ergonomic design that works equally well for left or right handed operators •• Type A and -SA – Designed for single 2.5 mm ferrules (SC, FC, ST, & D4) •• Type B and -SB – Cleans SC, SC2, FC, ST, DIN, D4, MU, LC, MT, MPO/MTP® without pins, MT-RJ without pins •• Type MPO – Accepts MPO/MTP connectors with pins •• Type MT-RJ – Accepts MT-RJ connectors with pins Features •• Compact and lightweight design is ideal for use in laboratories, assembly lines, or in the field •• Consistent cleaning results without IPA alcohol, which is toxic, flammable, and leaves a residue on fiber ends (white haze) •• Excellent anti-static properties for static sensitive applications and to minimize reattachment of dust to ferrule after cleaning •• Simple push button shutter operation exposes cleaning tape only when in use – minimizing unwanted dust •• Replaceable and cost effective cleaning tape •• Over 400 wipes per tape MTP is a registered trademark of US Conec. © 2007-2012, AFL, all rights reserved. 8500-00-2000 Revision 1D, 2.16.12 Specifications are subject to change without notice. 32 Cletop Cassette Cleaner Series Specifications PARAMETER Size Weight VALUE 130 x 75 x 40 mm (5.1 x 3.0 x 1.6 in) 160 g/0.35 lb Ordering Information DESCRIPTION CLETOP – S SERIES Cletop - SA with Blue Tape AFL NO. Cletop - SB with Blue Tape 8500-10-0029MZ Cletop - SB with White Tape Replacement Tape Type S - Blue Replacement Tape Type S - White CLETOP ORIGINAL SERIES Cletop Type A with Blue Tape Cletop Type A with White Tape Cletop Type B with Blue Tape Cletop Type B with White tape 8500-10-0016MZ 8500-10-0021MZ 8500-10-0017MZ Cletop for MT-RJ with pins (White Tape) 8500-10-0032MZ Cletop for MPO/MTP with pins (White Tape) 8500-10-0033MZ Replacement Tape Blue 8500-10-0012MZ Replacement Tape White 8500-10-0015MZ 8500-10-0020MZ 8500-10-0027MZ 8500-10-0011MZ 8500-10-0028MZ 8500-10-0014MZ © 2007-2012, AFL, all rights reserved. 8500-00-2000 Revision 1D, 2.16.12 Specifications are subject to change without notice. 33 NOTES NOTES © 2011, all rights reserved. BRO-03338 03.31.2014