Condensing Unit & Air Handler System CXN1824-070BY Air Handler CXN1836-105BY Air Handler CXN1848-120BY Air Handler CXN1860-140BY Air Handler mm mm Kg Kg 24000 (11770-26500) 18.00 208-230V/1/60Hz 187/254 3.15 44 54 1200 Direct 570/460 0.059 0.52 Centrifugal 9.53-8.11 Aluminum Fin-Copper Tube 413×66×457.2 19.4-46.1 3/4 Wired Control 532×540×1105 572×597×1160 57.0 61.0 35000 (15200-39900) 17.50 208-230V/1/60Hz 187/254 3.15 52 62 1954 Direct 900 0.5 3.60 Centrifugal 10.24-9.69 Aluminum Fin-Copper Tube 413×66×588.8 19.4-46.1 3/4 Wired Control 532×540×1224 572×607×1280 63.0 69.0 41000 (17810-46400) 17.50 208-230V/1/60Hz 187/254 3.15 52 63 2209 Direct 1050 0.75 4.60 Centrifugal 10.87-11.26 Aluminum Fin-Copper Tube 413×88×609.6 19.4-46.1 3/4 Wired Control 621×540×1224 656×622×1280 74.0 81.0 48000 (25100-54500) 17.50 208-230V/1/60Hz 187/254 3.15 52 63 2400 Direct 1050 0.75 4.60 Centrifugal 10.87-11.26 Aluminum Fin-Copper Tube 413×88×609.6 19.4-46.1 3/4 Wired Control 621×540×1224 656×622×1280 74.0 81.0 Btu/h Btu/h.W V/Ph/Hz A V dB (A) dB (A) W A rpm HP A Inch sq.ft m2 Mpa Mpa ºC mm mm Kg Kg m g/m Inch Inch m m CVX1824-070BY 24000 (11770-26500) 18.00 208-230V/1/60Hz 16.9 187/254V 57 67 9.26 R410A 2200 9.7 Internal Direct 1015/790 1/9 0.65 B IP44 Axial-Flow 3 18.11 0.8 720×515×255 835×382×600 3.17 1.66 19.4-46.1 IP24 610×610×620 651×651×620 52 56 Brazing 7.5 30 3/8 5/8 15 30 CVX1836-105BY 35000 (15200-39900) 17.50 208-230V/1/60Hz 30.0 187/254V 62 72 13.67 R410A 3010 13.2 Internal Direct 845/690 1/7 0.74 B IP44 Axial-Flow 3 22.04 0.8 795×525×290 907×382×600 3.17 1.66 19.4-46.1 IP24 710×710×735 773×773×755 71 75 Brazing 7.5 30 3/8 3/4 15 30 CVX1848-120BY 41000 (17810-46400) 17.50 208-230V/1/60Hz 40.0 187/254V 63 73 16.36 R410A 3010 13.2 Internal Direct 1080/900 1/4 1.25 A IP44 Axial-Flow 3 22.04 0.8 890×670×320 1020×430×760 3.17 1.66 19.4-46.1 IP24 710×710×850 773×773×1005 77 81 Brazing 7.5 60 3/8 7/8 15 30 CVX1860-140BY 48000 (25100-54500) 17.50 208-230V/1/60Hz 40.0 187/254V 63 73 16.36 R410A 4580 21.0 Internal Direct 1080/900 1/4 1.25 A IP44 Axial-Flow 3 22.04 0.8 890×670×320 1020×430×760 3.17 1.66 19.4-46.1 IP24 750×750×850 773×773×1005 96 110 Brazing 7.5 60 1/2 7/8 15 30 Model Type Indoor Unit Total Capacity Cooling Nominal (Min-Max) SEER Power Supply Electrical Data Min/Max Voltage Fuse Sound Pressure Level (H/M/L)* Sound Power Level (H/M/L)* Air Flow Volume Drive Type Speed Fan Motor Power Output Full Load Amp(FLA) Type Fan Diameter-Height Material Evaporator Length×Height×Width Operation Temp Cooling Drain Connection Size System Operation Control Dimension Weight Total Capacity Electrical Data Refrigerant Outdoor Unit Compressor Fan Motor Fan Condenser Outline Dimension (W×D×H) Package Dimension (L×W×H) Net Weight Gross Weight Model Cooling Nominal (Min-Max) SEER Power Supply Max. Overcurrent Protection Min/Max Voltage Sound Pressure Level (H/M/L)* Sound Power Level (H/M/L)* Type Power Input Rated Load Amp (RLA) Thermal Protector Drive Type Speed (H/M/L)* Power Output Full Load Amp (FLA) Insulation Class Safe Class Type Quantity Diameter-Height Material Face Area Permissible Excessive Operating Pressure for Discharge Side Permissible Excessive Operating Pressure for Suction Side Operation Temp Cooling Moisture Protection Outline Dimension (W×D×H) Dimension Package Dimension (L×W×H) Net Weight Weight Gross Weight Valve Connection Type Length Gas Additional Charge Connection Liquid Pipe Pipe Outer Diameter Gas Pipe Height Max Distance Length Btu/h Btu/h.W V/Ph/Hz V A dB (A) dB (A) m3/h rpm W A Inch mm ºC Inch -