Transcript
2016
F I E L D M e a s u r i n g I n s t r u me n t s short form catalog
test and measurement solutions for maintenance, repair and operation
DIGITAL CLAMP TESTERS
HIOKI’s Clamp On Meters = Quality, Safety, Durability and Reliability Ultra-thin clamps with independentopening doublelever design
3280-10 3288 3280-20 3288-20 True RMS
No metal exposure to ensure safety
›› Our most popular
clamp meter for all electrical applications
AC Current
Advanced core technology eliminates magnetization-induced heat and noise, even in heavy-current
›› 10μA resolution
for precise leak testing ›› Wide 5Hz to 15kHz bandwidth AC Current
10m/100m/1/ 10/20A
2
10/100A
100/1000A
10/100A
4.2 to 600V
4.2/42/420/600V
DC Voltage
420mV to 600V
420m/4.2/42/420/600V
Resistance
420 to 42 MΩ
Continuity
420 Ω
True RMS
›› -25℃ to 65℃ operating temperature; IP54 ›› CATIV 600V ›› Auto AC/DC detection 20/600 A 20/600 A
AC Voltage DC Voltage
600m/6/60/600/ 1500 V; 1700V peak
30 to 1000 Hz
100/1000A
AC Voltage
6/60/600/1000 V; 1000V peak
Frequency
True RMS
in UPS emergency / inverter energy-saving batteries and train motors equipment
DC Current
DC Current
Resistance
3287
›› Measure high currents ›› Ideal for cogenerator
42/420/1000 A
3283-20 CM4371 True RMS
True RMS
3282
True RMS
›› Tough and
durable body built for long use ›› CATIV 600V 30/300/1000 A; 1700A pk
3286-20
True RMS
CM4373 True RMS
›› Check for harmonics & power factor ›› High performance for single-phase to balanced 3-phase circuits
›› -25℃ to 65℃ operating temperature; IP54 ›› CATIV 600V ›› Auto AC/DC detection
20/200/1000A
600/2000 A
150/300/600 V
6/60/600/1000 V; 1000V peak
600/2000 A 300/600V; 750/1000V peak
600m/6/60/600/ 1500 V; 1700V peak
600.0 Ω to 600.0 kΩ
1k or 10kΩ
9.999 Hz to 999.9 Hz
30 to 1000 Hz
600.0 Ω to 600.0 kΩ 30 to 1000 Hz
9.999 Hz to 999.9 Hz
www.hioki.com
IP67 waterproof and dustproof 1st in the industry!
Earth Testing
›› 0 to 2000Ω measurement range ›› Innovative earthing rods and cable winder ›› Switchable between twoand three- electrode methods
Innovative sliding cover system lets you store test leads while connected
3490
üü Precise taut-band movement gives quick readings
Multi-range Analog
üü Constant battery check üü Luminous scale üü Optional lighted remote control test lead makes testing even faster
LED
o n FA IL S
fla s h
d w he n ins
a ti
1kV Digital
re
ul
IR4056/IR4057
es
üü Check for live circuits üü Bright red light warns of live voltage
Safety shutter prevents high voltage contact
üü Check for live circuits üü Digital reading at a glance üü Bright red light warns of
Insulation Testing
live voltage IR4057-20: üü 0.3s comparator response rate üü Digital bar graph
50V 125V 250V 500V 1000V 2500V 5000V
Analog 3490 100 MΩ 100 MΩ 4 GΩ
3455
5kV Insulation Tester
Step voltage testing, temperature compensation, temperature measurement, and leakage current
3455 250GΩ 500GΩ 1.00TΩ 2.50TΩ 5.00TΩ
Digital IR4056-20
IR4057-20
100 MΩ 250 MΩ 500MΩ 2000MΩ 4000MΩ
100 MΩ 250 MΩ 500MΩ 2000MΩ 4000MΩ
Rated Current/Short Circuit Current
1mA (Tolerance: 1 to 1.2 times of the rating value)
2mA
1.2mA
AC V Testing
0 to 600 V (50/60 Hz)
50 to 750V
420V/600V
±50V to 1.00kV
4.2V to 600V
±5% of maximum scale value
±5% rdg. ±5dgt.
±2.3% rdg. ±8 dgt. (ACV)
DCV Testing Best Accuracy
www.hioki.com
EARTH, DIGITAL & ANALOG INSULATION RESISTANCE TESTERS
FT6031
3
NON-CONTACT TESTING
Non-Metallic Contact Phase Detection CATIV 600V/ CATIII 1000V Safe
PD3129-10Phase Detector
Bright Red LED and clear buzzer
›› 70V to 1000V AC ›› Auto power off saves battery life
Green direction arrow makes it easy to identify normal phase
Extra-wide clips to clamp up to Ø 40mm thick conductors
FT3424 Lux Testing Test LED lighting
Analog output
Detachable sensor head w/ optional cord
›› DIN 5032-7:1985 class B, JIS C 1609-1: 2006 general AA class compliant ›› 0 to 200,000 lx ›› Timer hold function ›› Memory function
Ultra-sensitive sensor offers ±2%rdg. linearity
›› 8 to 14μm measurement wavelength of ›› Two-beam laser marker ›› FT3700-20: 12:1 long focus, φ 83mm at a 1m distance ›› FT3701-20: 30:1 precise focus, φ 100mm at a 3m distance
FT3700 Series Infrared Temperature 2-point laser marker clearly defines target
FT3405/3406
Ergonomic handle
Tacho Testing
Long noncontact distance of 500mm Dust-proof and drop-proof (IP 50) 4
Absolutely NO metal exposure ensures safety at the worksite
Signal output, (FT3406 only) analog output and pulse output
›› ›› ›› ››
Non-contact infrared sensor
-60°C to 760°C with 0.1°C resolution (FT3701-20)
500mm non-contact detection distance 0.5 r/sec to 99990 r/min Best sampling: 62.5 ms Best accuracy: ±1dgt.
www.hioki.com
CATIV 600V Safe, Accuracy and Repeatability
Zero adjustment not required
›› ›› ›› ›› ›› ››
Slim jaw for the narrowest spaces also minimizes dirt
Battery HiTESTER
Wide 60V range
600V circuit protection - no fuse required
Ultra-bright diode Bluetooth® light lets you find connectivity hard-to-reach spots for wireless in dark locations data transfer to AndroidTM phones (FT6381)
For multiple grounded systems 0.20Ω to 1600Ω, ±1.5% rdg. best accuracy 20mA to 60A current testing Measurements update every 1/2 second IP40 dust and moisture protection 35 hours of continuous use
3554
3246-60 Pencil HiTESTER
Store up to 4800 sets of test data
›› ›› ›› ››
Test probe fits neatly in the back
4.2V to 600V AC 420mV to 600V DC Resistance 150 hours of continuous use on a single battery
PD3259
Digital Phase Detector Check phase rotation and measure voltage with a single unit
Comparator function, auto data hold and auto data storage
Extra-strong test probes
›› Ideal for testing UPS batteries ›› 3mΩ to 3Ω over 4 resistance ranges ›› 1 μΩ best resolution ›› 6 or 60 DC V voltage testing with 1mV resolution ›› -10 to 60°C temperature testing with 0.1°C resolution ›› 1 time/sec sampling ›› Store 200 sets of comparator values ›› Download test results and upload comparator tables via USB interface and free software ›› Also available: Model 3555 for compact batteries covering 300mΩ to 30Ω and 3 or 30 DCV testing
www.hioki.com
Large display and IP54
GROUND CLAMP, BATTERY TESTER, DMM & PHASE DETECTOR
FT6380 Series Clamp On Earth Tester
Non-metallic contact voltage clips
›› Measure 3-phase AC V and frequency ›› Phase detection, open phase and prediction of ground phase, three phase 90.0 to 520.0 V AC ›› Use on covered cables and metal terminals 5
POWER LOGGING, DEMAND POWER & POWER QUALITY ANALYSIS
PW3360
PW3198
Clamp On Power Logger
Power Quality Analyzer
LAN and USB interfaces
3 types of power supplies
Store data in 2GB SD Card
Log 1 year of data at 30 second intervals ›› 3P4W from 0.5A to 5000A load, 0.05A to 5.0A leak ›› 300W to 9MW power ›› Measure up to 780V with a 1000V display range ›› Quick and easy set up ›› Log all power parameters continuously with no gaps ›› Calculate electricity cost ›› Optional 8 hour rechargeable battery ›› Optional advanced PC software Model PW3360-21: ›› Harmonic measurement to the 40th order
PW3365
›› ›› ›› ›› ›› ›› ›› ›› ›› ››
1P2W to 3P4W 50/60/400Hz measurement GPS clock synchronization (optional) Power factor, sags, swells, flicker, transients Harmonics to the 50th order Accurate high speed transient capture at 2MHz sampling Detection and waveform display Four current and four voltage channels Advanced PC software High harmonic
3197
Clamp On Power Logger
Power Quality Analyzer
4MB of internal memory SD Card slot
Non-metallic contact power meter with completely covered voltage clips ›› Dedicated voltage sensor delivers the world’s first no-metal-contact measurement. ›› Measure between 90V to 520V in a single 400V range ›› Even measure leakage current as low as 50 mA with optional clamp-on leakage sensor ›› Store months of data on SD cards ›› QUICK SET function guides you in making the right connections
6
High performance Class A PQA to manage all power quality problems
Multilingual display
USB interface for data download
Large, brilliant LCD screen lets you view event list and waveforms in a single window ›› 1P2W to 3P4W ›› Monitor inrush current, voltage swell, voltage dips, transient over-voltage, interruptions ›› Measure and record power and power factor, active/ reactive energy, demand, load fluctuation (with graph display), voltage and current ›› PC software bundled ›› Measure kWh
www.hioki.com
Data Loggers
h-
Rear kickstand
p ro
of c o n st
Sp
io n
LR5001: 2ch Temperature and humidity
Backup function preserves important data
ru
ct
la s
Easy-to-read dual display
Record up to 60,000 data points per channel
COMPACT DATA LOGGERS
LR5000 Series
Compact data loggers with docking station to capture temperature, humidity, voltage, current or instrumentation signals
›› 7 models to choose from ›› Long 2-year battery life ›› -20°C to 70°C operating temperature range ›› Transfer data to Communication Adapter even during recording ›› Bundled utility software for quick and easy data analysis LR5031: 2ch Instrumentation 4-20mA DC
LR5011: 1 channel temperature
Record pressure sensor output and monitor fluctuations in air or oil pressure
Visually monitor temperature changes in the warehouse LR5041/LR5042/ LR5043: 3 models w/1ch 50mV/5V/50V DC
Record pyranometer output to evaluate solar panel insulation
Record and monitor leakage trends LR5051: 2ch AC Current with separate clamp sensors 500.0 mA to 1000A
Transfer Data to PC with Simple Adapter or More Advanced Data Collector
LR5091 LR5092-20
www.hioki.com
7
DIGITAL MULTIMETERS
DT4200 Series Digital Multimeters Hioki’s proprietary ASIC delivers the world’s fastest measurement response of 0.6s
High-End
DT4281
Standard
DT4282
›› 630 Hz low-pass filter
cuts harmonics ›› Red display warns of over-voltage ›› Internal memory for 400 data points ›› Clamp sensor or direct current input models ›› DT4900 Optional PC Management Software
DT4252
DT4253
DT4254
Pocket
DT4255
DT4256
›› Max 1700 V voltage-dedicated model ›› Fuse-protected model harsh Work environments ›› Super noise suppression with 100/500 Hz low-pass
filter gets faster readings
›› Red LED over-voltage warning also aids in continuity
checks ›› Clamp sensor or direct current input ›› HVAC, instrumentation and temperature testing model ›› DT4900 Optional PC Management Software
Supporting Clamp On Probes
DT4221
DT4222
›› Effortless operation
with test lead storage clips behind the DMM ›› Runs on one AAA battery, for simple replacement ›› No current terminals for ultimate safety
DT4900 Convert from female BNC to male banana-plug to connect
9010-50
9018-50
››500A AC ››6 ranges ››± 2% accuracy
››500A AC ››6 ranges ››± 1.5% accuracy
9132-50
››1000A AC ››6 ranges ››± 3% accuracy
9704
All of the products appearing in this catalog are CE marked unless otherwise indicated. HIOKI products labeled with the CE marking are designed for fulfillment of these over-voltage category requirements. In order to ensure safe use of this instrument, please use a device showing the CAT marking that is appropriate for the place of use. Note: Company names and Product names appearing in this catalog are trademarks or registered trademarks of various companies.
DISTRIBUTED BY
HEADQUARTERS: 81 Koizumi, Ueda, Nagano, 386-1192, Japan TEL +81-268-28-0562 FAX +81-268-28-0568 http://www.hioki.com / E-mail:
[email protected] HIOKI USA CORPORATION: TEL +1-609-409-9109 FAX +1-609-409-9108 http://www.hiokiusa.com / E-mail:
[email protected] All information correct as of December 1, 2015. All specifications are subject to change without notice.
0003E5-husa-s-2015-12B