Fieldserver Data Sheet

   EMBED


Share

Transcript

ProtoNode for Square D LONWORKS®, BACnet® MS/TP & BACnet/IP® Multi-Protocol Gateway The ProtoNode for Square D is an external, high performance, low cost, Building Automation multi-protocol gateway preprogrammed for Square D’s Meters to instantly support Modbus RTU to BACnet MS/TP, BACnet/IP and LONWORKS. The ProtoNode has nine configurations which are preprogrammed and tested by Square D. These configurations are stored with in memory and selectable via DIP switches for each of the following meters to support BACnet or LonWorks: • PM800 (Series), PM1000, PM200, PM700, DM6000, ION6200, ION6200M, CM4000, ION7550, ION7650, ION8600 ProtoNode RER ProtoNode LER The ProtoNode RER and LER has been design for easy field installation. DIP switches are used to set a particular meter’s configuration to automatically load on power up and to set the field protocols settings (Baud Rate Node-ID, MAC address). Thus, the user simply sets the DIP switches, connect the cables, apply power and the unit is installed. Two ProtoNodes are available that fulfill the nine Square D configurations: ProtoNode RER • Supports Modbus RTU to BACnet MS/TP & BACnet/IP. • Includes two RS-485 and one Ethernet port • FieldServer Commercial ordering part number FPCN32-103-112-0502. • FieldServer Government ordering part number FPCN32-103-112-0502G. • BACnet BTL certified (B-ASC). ProtoNode LER • Supports Modbus RTU to LonWorks. • Includes one FTT-10 LonWorks port plus one 10/100 Ethernet and one RS485 port. • FieldServer ordering part number FPC-N33-103-4010501. • FieldServer ordering part number FPC-N33-103-4010501G. • LonMark Certified . Features/Benefits  All nine configurations are Square D tested and approved.  Configurations are pre-loaded and into each of the units so they instantly work with the meters.  No mapping of Modbus registers to BACnet or LonWorks are necessary. Saves time installing the product.  Set the DIP switches, connect the cable, and turn the power on. Plug and play install.  BACnet Testing Labs BTL marked for the ProtoNode RER and LonMark Certified for the ProtoNode LER. Best of Breed.  Can support multiple meters and other protocol on one ProtoNode, but must be configured by Square D. LONWORK® is a registered trademark of Echelon Corp. BACnet® is a registered trademark of ASHRAE. 09/11 FieldServer Technologies, 1991 Tarob Court, Milpitas, California 95035 USA Web: www.protocessor.com Tel: 408-964-4433, FAX: 408-262-9042, Toll-Free: 800-317-8319 Email: [email protected] Specifications Supported Electrical Connections: ProtoNode Serial (Model RER): • 1 - 6 pin Phoenix Connector Supported protocols: • LONWORKS (ProtoNode LER only) Serial (RS-485) Protocols (ProtoNode LER and RER)  1 RS-485 +/- Ground port • Allen Bradley DF1  Power +/- Frame Ground port • BACnet MS/TP • DNP 3.0 Serial • Metasys N2 by JCI • 1 - 3 pin Phoenix connector RS-485  1 RS-485 +/- Ground port • 1 Ethernet -10/100 Ethernet port ProtoNode LONWORKS (Model LER): • 1 - 6 pin Phoenix Connector Ethernet Protocols (ProtoNode LER and RER) • Allen Bradley EtherNet/IP  1 RS-485 +/- Ground port • Allen Bradley CSP/TCP  Power +/- Frame Ground port • BACnet/IP • 1 Ethernet -10/100 Ethernet port • BACnet Ethernet • 1 FTT-10 LONWORKS port • Modbus TCP/IP Operating Power Requirements: 9-30 VDC or VAC or 5 VDC Current draw @ 12V RER @ 12V = 150 mA LER @ 12V = 279 mA FieldServer Technologies has a full library of over 100 drivers so check with ProtoCessor sales to determine what additional protocols are available to meet specific application needs. Environmental Operating Temp.: -40oF to 187oF (-40oC to 85oC) Relative Humidity: 5-90% RH, non-condensing Enclosure Dimensions: 4.52 x 3.25 x 1.60 inches (L x W x H) (11.49 x 8.25 x 4.06 cm) Approvals BACnet Testing Labs (BTL) B-ASC on ProtoNode RER LonMark 3.4 Certified on ProtoNode LER CSA approved to UL 916 standard RoHS Compliant CE Mark FCC Part 15 OPC Self Certified to Compliance DNP3 Conformance Tested Warranty Warranty: Two years return to factory FieldServer Technologies offers a full range of OEM devices to enable manufacturers to easily provide the protocols their customers demand:  ProtoCessor - embedded protocol translator  ProtoCarrier - daughter cards to enable addition of ProtoCessor without hardware redesign  ProtoConnect - semi-custom protocol OEM solution  ProtoNode - external fully enclosed protocol OEM solution. In addition to the ProtoNode LER and RER. 09/11 FieldServer Technologies, 1991 Tarob Court, Milpitas, California 95035 USA Web: www.protocessor.com Tel: 408-964-4433, FAX: 408-262-9042, Toll-Free: 800-317-8319 Email: [email protected]