Preview only show first 10 pages with watermark. For full document please download

Final Single-event-effects Test Report

   EMBED


Share

Transcript

Final Single-Event-Effects Test Report R6, 600V, Size-3, N-Channel, MR (Wafer Fab 5) March 2006 - T.A.M.U. International Rectifier Corp. SEE Test Report March 2006 – T.A.M.U. Table of Contents Introduction ................................................................................................ 1 Test Method ............................................................................................... 1 Test Plan ..................................................................................................... 1 Test Facility ................................................................................................ 2 Results ........................................................................................................ 2 SEE Data Run Number Index .................................................................... 4 Device Operating Area .............................................................................. 4 Conclusions ................................................................................................ 7 Appendix A - Log Sheets (SEE Run Data) .............................................. 9 Appendix B - T.A.M.U. Facility Data and Graphs ..........................…. 16 Appendix C - I.R. Test Plan and Procedure .…….................................. 25 Appendix D - Test Circuit Schematic Diagram .........................…....... 28 Appendix E - TAMU TVDG Ion Species, Surface LET & Range ....... 30 Appendix F - Post-SEE Electrical Measurements ….………………... 35 i International Rectifier Corp. SEE Test Report March 2006 – T.A.M.U. INTRODUCTION On December 7th 2005 and March 23rd 2006, International Rectifier Corp. (IR) tested several product types for Single Event Effects (SEE) hardness. The irradiation was performed at Texas A&M University, using the K500 Superconducting Cyclotron. Three ion species were used to characterize and verify the SEE hardness of each product type. The product types submitted for evaluation and this report are included in Table 1 below: Table 1 Product Types Tested Product Type BVDSS Rating Gen. / Channel / Process Wafer Lot IRH67C30 600 Volts R6 / Size-3 / N / 600V ER54631A IRH67C30 600 Volts R6 / Size-3 / N / 600V ER61055B IRH67C30 600 Volts R6 / Size-3 / N / 600V ER61055C IRH67C30 600 Volts R6 / Size-3 / N / 600V ER61055D The wafer lot noted above is the lot from which from which the test samples originated. For each product type, the results of testing herein are applicable to all other wafer lots having the same design and process. Additionally, Mr. Louis Jaquish of Defense Supply Center Columbus (DSCC-VQE) has performed an audit of IR for the purpose of assigning lab suitability and has granted IR a Letter of Lab Suitability for Test Method 1080 in June 1998. Similarly, Mr. Thomas Hood had grant IR a Letter of Lab Suitability for Test Method 1080 in April 2005 for Texas A&M Cyclotron Facility. TEST METHOD The test method used as a guide in developing the test plan is MIL-STD-750, Test Method 1080. The test method establishes the basic requirements for the performance of the test. Additionally, DSCC has established a minimum acceptance level of three (3) devices for each insitu bias condition. Test method 1080, in conjunction with DSCC requirements, was utilized to write the test plan. TEST PLAN and PROCEDURE The test plan is included in Appendix C. In summary, the testing occurred in the following manner: All devices / test samples were built and electrically tested in TO-3 packages. The lid was removed from each test sample at the test site or the samples were produced without the lid. Up to 18 test samples were loaded onto the test board and placed into the beam line, under specific air-gap conditions. The desired test sample was positioned into the beam line, and when ready the beam shutter was removed beginning the irradiation of the test sample. Once the desired fluence was achieved the beam was automatically shuttered and the bias removed. The biasing equipment then subjected the test samples to gate stresses up to 20V. The Ion with its LET, Range and Energy must be selected for the worst-case SEE Response of the Device-Under-Test technology. 1 International Rectifier Corp. SEE Test Report March 2006 – T.A.M.U. TEST FACILITY The K500 Superconducting Cyclotron is equipped with the necessary dosimetry to ensure the ion beam is meeting the customer expectation. A printout of the runs, included in Appendix B, also includes the beam parameters, i.e., LET, energy, Range, etc., for each run. Table 2 summarizes the beam criteria for the 3 ion species utilized. Table 2. Ion Beam Criteria Ion Kr Xe Au Air-Gap (cm) 1.43 1.43 1.43 LET MeV/(mg/cm2) 38.4-20.0 (32.4) 60.6-39.4 (56.2) 93.5-84.0 (89.5) Energy MeV 342-1958 (679) 683-2954 (1060) 965-2433 (1555) Range μm 42-305 (83.3) 56-259 (83.5) 56-128 (84.0) Range of values denotes ion beam conditions for penetration depth from First Epi to Substrate End. Values in ( ) denote ion beam conditions under worst-case SEE Response (at Epi-Buffer). The fluence and flux specified for this test was 3E5 ions/cm2 and 1E4 ions/cm2/sec, respectively. The beam diameter was set to 1.78 cm. The angle of incidence was set to zero (normal to the die surface). RESULTS The insitu bias conditions, where 0 failures occurred for each product type, are shown in Table 3. These results are shown graphically in Figure 1 as a plot of the Safe Operation Area (SOA). Each point on the graph, or insitu bias condition, has been verified by irradiating and subsequent electrical testing of a minimum of 3 devices, with no valid failures allowed. The devices were returned to IR and tested using production ATE. The results of the test were inspected and matched to the notes taken during the test, see Appendix F. The post-irradiation data correlates with the expected test results. It should be noted that acceptance is assumed for product types operating at conditions below those tested herein. For an example the IRH67C30 was not tested under VGS bias conditions of 0V through -15V with the Krypton ion. The test engineer made a calculated risk assessment based on SEE Process History and chose to begin characterization and verification at VGS = -20V. The insitu acceptance at the -20V was then extended to the lower VGS bias voltages. Furthermore the extension of more stressful conditions to less stressful conditions shall also apply to the LET conditions of the various ion species. For example successful operation using the Au ion (LET larger than that of Xe and Kr ions) shall also imply that the Krypton or Xenon or any other ion with a smaller LET, shall also be acceptable and not require verification. The different runs and respective test conditions are all tabulated in Appendices A and B. Table 4 may be used as an index to identify which runs apply to a specific product type with a specific ion. Unlisted Runs are not related to this report. 2 International Rectifier Corp. SEE Test Report March 2006 – T.A.M.U. Table 3 Device Insitu Bias Conditions (VDS vs. VGS) with Ion Species Device Type / Part No. IRH67C30 (R6, Size-3, 600V, N-channel) ER61055 B Device Type / Part No. IRH67C30 (R6, Size-3, 600V, N-channel) ER61055 B ER61055 C ER61055 D Device Type / Part No. IRH67C30 (R6, Size-3, 600V, N-channel) ER61055 B ER61055 C ER61055 D Ion Energy LET Range Kr 809 30.5 101 Xe 1279 53.7 101 Au 2433 84 128 Ion Energy LET Range Kr 679 32.4 83.3 Xe 1060 56.2 83.5 Au 1555 89.5 84 Kr 679 32.4 83.3 Xe 1060 56.2 83.5 Kr 679 32.4 83.3 Xe 1060 56.2 83.5 Ion Energ y LET Range VGS= 0V VGS= -3V VGS= -4V VGS= -5V VGS= -6V VGS= -12V VGS= -20V Kr 679 32.4 83.3 Qualified Qualified Qualified Qualified Qualified Qualified 600V Xe 1060 56.2 83.5 Qualified Qualified Qualified Qualified Qualified 600V Au 1555 89.5 84 Qualified 600V Kr 679 32.4 83.3 Qualified Qualified Qualified Qualified Qualified Qualified 600V Xe 1060 56.2 83.5 Qualified Qualified Qualified Qualified 600V Au 1555 89.5 84 Kr 679 32.4 83.3 Qualified Qualified Qualified Qualified Qualified Qualified 600V Xe 1060 56.2 83.5 Qualified Qualified Qualified Qualified Qualified 600V Au 1555 89.5 84 Qualified Qualified 600V VGS= 0V VGS= -5V VGS= -10V VGS= -15V 620V SEB@630V 620V SEB@630V 580V SEB@600V 610V SEB@620V 610V SEB@620V 590V SEB@600V 610V SEB@620V 620V SEB@630V 110V SEB@120V 610V SEB@620V 180V SEB@190V VGS= 0V VDS= 150V VDS= 300V VDS= 450V VDS= 600V -14V SEGR@-16V -28V SEGR@-30V -14V SEGR@-16V -28V SEGR@-30V -14V SEGR@-16V -28V SEGR@-30V -12V SEGR@-14V 590V SEB@600V -16V SEGR@-18V -29V SEGR@-30V -14V SEGR@-16V 605V SEB@610V -14V SEGR@-16V -14V SEGR@-16V -27V SEGR@-28V -14V SEGR@-16V -30V SEGR@-31V -14V SEGR@-16V -26V SEGR@-27V -12V SEGR@-14V -25V SEGR@-26V -12V SEGR@-14V 610V SEB@615V 600V SEB@610V VGS= -20V 600V Qualified Note: “Qualified” indicates part is qualified by extension of insitu bias testing at higher VGS/VDS level. See Concluding Tutorial for more details. 3 International Rectifier Corp. SEE Test Report March 2006 – T.A.M.U. Table 4 Run Number Index Device Type / Part Number Wafer Lot Number ER61055B (Worst-Case Characterization) ER61055B (Validation) IRH67C30 (R6, ER61055C (Validation) Size-3, 600Volts, ER61055D (Validation) Ion Specie Kr Xe Run Date 12-07-2005 12-07-2005 Au 12-07-2005 Kr 03-23-2006 Xe 03-23-2006 Au 03-23-2006 Kr 03-23-2006 Xe 03-23-2006 Kr 03-23-2006 Xe 03-23-2006 Au Kr Xe Au Kr Xe Kr Xe Au 03-23-2006 03-23-2006 03-23-2006 03-23-2006 03-23-2006 03-23-2006 03-23-2006 03-23-2006 03-23-2006 N-channel) ER61055B (Qualification) ER61055C (Qualification) ER61055D (Qualification) * two (2) out of three (3) samples passed insitu point. 4 Run Number 084 to 128 203 to 247 316 to 360, 386 to 442 1 thru 21, 72 thru 82 353 thru 382, 441 thru 450, 462 thru 463 678 thru 707 22 thru 48, 86 thru 97 383 thru 403 49 thru 68, 101 thru 115 404 thru 422, 436 thru 440, 451 thru 461 708 thru 715 69, 70, 71 423, 424, 425 705, 707 * 83, 84, 85 430, 431 * 98, 99, 100 433, 434, 435 711, 713, 714 International Rectifier Corp. SEE Test Report March 2006 – T.A.M.U. Figure 1a Device Safe Operating Area (Characterizations) ER54631A ER61055B R6 600VN ER54631A Bragg Peak and Threshold with Kr R6 600VN ER61055B Bragg Peak and Threshold with Kr 600 630 550 620 500 610 400 VGS=-5V 350 VGS=-10V 300 VGS=-15V 250 VGS=-20V VGS=-5V 600 Threshold VDS Bias Threshold VDS Bias VGS=0V VGS=0V 450 VGS=-10V 590 VGS=-15V 580 VGS=-20V 570 200 560 150 100 550 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 0 320 20 40 60 80 100 120 Penetration Range µm ) Penetration Range (µm) R6 600VN ER54631A Bragg Peak and Threshold with Xe R6 600VN ER61055B Bragg Peak and Threshold with Xe 600 640 550 630 500 VGS=0V 620 VGS=-5V 610 VGS=0V 400 Threshold VDS Bias Threshold VDS Bias 450 VGS=-10V 350 300 VGS=-15V 250 VGS=-20V VGS=-5V VGS=-10V 600 VGS=-15V 590 VGS=-20V 580 200 570 150 560 100 550 50 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 0 320 20 40 R6 600VN ER54631A Bragg Peak and Threshold with Au 80 100 120 R6 600VN ER61055B Bragg Peak and Threshold with Au 600 600 550 550 500 450 VGS=0V 500 VGS=-5V 450 400 350 VGS=-15V 300 VGS=-20V 250 VGS=0V VGS=-5V 400 VGS=-10V Threshold VDS Bias Threshold VDS Bias 60 Penetration Range µm ) Penetration Range (µm) VGS=-15V 300 VGS=-20V 250 200 200 150 150 100 100 50 VGS=-10V 350 50 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 0 20 40 60 80 Penetration Range µm ) Penetration Range (µm) 5 100 120 140 International Rectifier Corp. SEE Test Report March 2006 – T.A.M.U. Figure 1 Device Safe Operating Area R6 600VN ER61055B Bragg Peak and Threshold with Kr R6 600VN ER61055C Bragg Peak and Threshold with Kr 650 0 650 0 VGS=0V VGS=-10V VGS=-15V VGS=-20V 550 -20 VGS=-5V 600 VGS=-10V VGS=-15V VGS=-20V 550 500 80 100 120 140 160 180 200 220 240 260 280 300 500 -30 320 0 20 40 60 80 100 120 140 160 180 200 220 240 260 Penetration Range (µm ) 650 0 VGS=0V VGS=-10V VGS=-15V VGS=-20V 550 -20 Threshold VDS Bias -10 VGS=-5V Threshold VGS Bias Threshold VDS Bias 600 VGS=-5V 600 VGS=-15V VGS=-20V 550 80 100 120 140 160 180 200 220 240 260 280 300 500 -30 320 0 20 40 60 80 100 Penetration Range µm) 120 140 160 180 200 220 240 R6 600VN ER61055C Bragg Peak and Threshold with Xe VGS=-20V 550 Threshold VDS Bias -10 VGS=-15V Threshold VGS Bias Threshold VDS Bias VGS=-10V 0 VGS=-5V 600 VGS=-10V 500 100 120 140 160 180 200 220 240 260 280 300 VGS=-20V 550 VDS=600V 500 -20 320 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 -20 320 Penetration Range µm) Penetration Range µm) R6 600VN ER61055D Bragg Peak and Threshold with Au R6 600VN ER61055B Bragg Peak and Threshold with Au 650 650 0 0 VGS=0V 600 -2 VGS=-10V VGS=-15V VGS=-20V 550 -4 Threshold VGS Bias VGS=-5V Threshold VDS Bias VGS=0V Threshold VDS Bias -10 VGS=-15V VDS=600V 80 -30 320 VGS=0V VGS=-5V 60 300 R6 600VN ER61055D Bragg Peak and Threshold with Xe VGS=0V 600 40 280 650 0 20 260 Penetration Range (µm ) 650 0 -20 VDS=600V 500 60 -10 VGS=-10V VDS=600V 40 -30 320 0 VGS=0V 20 300 R6 600VN ER61055B Bragg Peak and Threshold with Xe R6 600VN ER61055D Bragg Peak and Threshold with Kr 650 0 280 Penetration Range µm) Threshold VGS Bias 60 Threshold VGS Bias 40 VGS=-5V 600 -2 VGS=-10V VGS=-15V VGS=-20V 550 -4 VDS=600V VDS=600V 500 500 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 0 -6 320 20 40 60 80 100 120 140 160 180 Penetration Range µm) Pe netration Range (µm ) 6 200 220 240 260 280 300 -6 320 Threshold VGS Bias 20 -20 VDS=600V VDS=600V 0 -10 Threshold VGS Bias -10 Threshold VDS Bias VGS=-5V Threshold VGS Bias Threshold VDS Bias VGS=0V 600 International Rectifier Corp. SEE Test Report March 2006 – T.A.M.U. CONCLUSION IRH67Cx0 LET=32.4; LET=56.2; Kr; 83.3µm; Xe; 83.5µm; 1060MeV 679MeV 600 600 600 600 600 600 600 LET=89.5; Au; 84µm; 1555MeV 600 600 LET=32.4; Kr; 83.3μm; 679MeV 700 Bias VDS (Volts) VGS Bias 0 -4 -12 -20 IRH67Cx0(R6,600V,N,MR) SEE-SOA 600 500 LET=56.2; Xe; 83.5μm; 1060MeV 400 300 LET=89.5; Au; 84μm; 1555MeV 200 100 March 28th 2006 TAMU: 1.43cm Air-Gap Xe @ Au @ Kr @ 15AMeV 15AMeV 15AMeV 0 0 -4 -8 -12 Bias VGS (Volts) -16 -20 The 600-Volt N-Channel R6 (IRHC67C30) had demonstrated very well in SEE Hardness: 1. SEE-hard to Krypton (Kr) ion at 100% Rated VDS (600V) & 100% Rated VGS (-20V) applied. 2. SEE-hard to Xenon (Xe) ion at 100% Rated VDS (600V) & -12V VGS applied. 3. SEE-hard to Gold (Au) ion at 100% Rated VDS (600V) & -4V VGS applied. 7 International Rectifier Corp. SEE Test Report March 2006 – T.A.M.U. CONCLUDING TUTORIAL The following is presented to help the reader understand the basis on which SEE Testing is extended to the other part numbers. Extending Single Event Effects Testing International Rectifier has designed Single Event Effects (SEE) experiments to maximize facility usage using four, industry accepted, assumptions as follows: I. Test results for one die size are representative of other die sizes, if the process and design rules are not changed. In other words the scaling of die size has no affect if all other variables are held constant. Please note that for a given voltage and technology, there are no differences in design and process for the various sizes of IR’s radiation hardened MOSFET die, thus the assumption is valid. In reality, IR will always test the largest available die size. We consider this a worst-case scenario. The industry standard for acceptance of a given in-situ bias condition, is the acceptable performance of three or more devices at the specified conditions. Presently a supplier could achieve this standard with size 1 die thru size 6 die. We believe that use of the smaller die reduces the probability of failure, and thus reduces the chance of a SEE problem being discovered. The size 1 die are about one-fourth the size of the size 6 die. Thus successfully testing three size 6 die is roughly equivalent to testing 12 size 1 die. This results in a savings of valuable test time at the SEE test facility, without degrading the final test result. II. Acceptable test results taken at given VGS and VDS conditions are applicable to lower VGS and VDS conditions. In other words an acceptable test result (>= 3 devices passing) at VGS = -15V and VDS = 200V, would also apply to VGS = -10, -5 or 0V at the same or lower VDS condition. In several cases parts have been tested at the worst-case in-situ bias condition of VGS = -20V and VDS = max rated BVDSS. With acceptable test results, the safe operation area, has been extended from VGS = 0 to –20V and VDS from 0 to the max rating. It is not necessary to verify every point below the accepted in-situ bias conditions. Again this saves valuable experiment time. III. Acceptable test results taken with a given LET, would also apply at other lower LETs. It is generally accepted that successful test results with Iodine, for example, implies the device would be hard against Bromine, Krypton, Nickel, etc., ion species with a lower LET. It is not necessary to test at each lower LET, again saving valuable test time. IV. The package used has no effect on the SEE hardness of a die. The die are characterized fully exposed to the ion beam. In other words the lid of the package is removed making the die visible. This removes the package as a variable when comparing test results. As a rule IR uses the common TO3 package for mounting die for SEE tests. Each of the assumptions above is generally accepted within the industry. IR has verified their validity over the last several years and makes appropriate use of them to maximize the benefit for our customers. 8 International Rectifier Corp. SEE Test Report March 2006 – T.A.M.U. Appendix A Log Sheets (SEE Run Data) 9 SEE Facility Run # Ion 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 LET Energy Range Flux 2 2 µm MeV.cm /mg MeV #/cm /sec 600V, Size-3, N, MR, R6-MidVoltage to Krypton 27.2 Kr 3/23/2006 TAMU 1 Kr 3/23/2006 TAMU 2 27.2 Kr 3/23/2006 TAMU 3 27.2 Kr 3/23/2006 TAMU 4 27.2 Kr 3/23/2006 TAMU 5 27.2 Kr 3/23/2006 TAMU 6 27.2 Kr 3/23/2006 TAMU 7 27.2 Kr 3/23/2006 TAMU 8 27.2 Kr 3/23/2006 TAMU 9 27.2 Kr 3/23/2006 TAMU 10 27.2 Kr 3/23/2006 TAMU 11 27.2 Kr 3/23/2006 TAMU 12 27.2 Kr 3/23/2006 TAMU 13 27.2 Kr 3/23/2006 TAMU 14 27.2 Kr 3/23/2006 TAMU 15 27.2 Kr 3/23/2006 TAMU 16 27.2 Kr 3/23/2006 TAMU 17 27.2 Kr 3/23/2006 TAMU 18 27.2 Kr 3/23/2006 TAMU 19 27.2 Kr 3/23/2006 TAMU 20 27.2 Kr 3/23/2006 TAMU 21 27.2 Kr 3/23/2006 TAMU 22 27.2 Kr 3/23/2006 TAMU 23 27.2 Kr 3/23/2006 TAMU 24 27.2 Kr 3/23/2006 TAMU 25 27.2 Kr 3/23/2006 TAMU 26 27.2 Kr 3/23/2006 TAMU 27 27.2 Kr 3/23/2006 TAMU 28 27.2 Kr 3/23/2006 TAMU 29 27.2 Kr 3/23/2006 TAMU 30 27.2 Kr 3/23/2006 TAMU 31 27.2 Kr 3/23/2006 TAMU 32 27.2 Kr 3/23/2006 TAMU 33 27.2 Kr 3/23/2006 TAMU 34 27.2 Kr 3/23/2006 TAMU 35 27.2 Kr 3/23/2006 TAMU 36 27.2 Kr 3/23/2006 TAMU 37 27.2 Kr 3/23/2006 TAMU 38 27.2 Kr 3/23/2006 TAMU 39 27.2 Kr 3/23/2006 TAMU 40 27.2 Kr 3/23/2006 TAMU 41 27.2 Kr 3/23/2006 TAMU 42 27.2 Kr 3/23/2006 TAMU 43 27.2 Kr 3/23/2006 TAMU 44 27.2 Kr 3/23/2006 TAMU 45 27.2 Kr 3/23/2006 TAMU 46 27.2 Kr 3/23/2006 TAMU 47 27.2 Test Date 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 Fluence 2 #/cm 10 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 Angle BeamDia. deg cm. Device Type Wafer Lot No. DUT ID 1 1 1 1 1 2 2 2 2 3 3 3 3 3 3 4 4 4 4 5 5 7 7 8 8 8 8 8 9 9 9 9 10 10 10 10 11 11 11 12 12 12 12 12 12 12 12 Socket # Wafer Lot ER61055, Split B, C & D A1 IRH67C30 ER61055B A1 IRH67C30 ER61055B A1 IRH67C30 ER61055B A1 IRH67C30 ER61055B A1 IRH67C30 ER61055B A2 IRH67C30 ER61055B A2 IRH67C30 ER61055B A2 IRH67C30 ER61055B A2 IRH67C30 ER61055B A3 IRH67C30 ER61055B A3 IRH67C30 ER61055B A3 IRH67C30 ER61055B A3 IRH67C30 ER61055B A3 IRH67C30 ER61055B A3 IRH67C30 ER61055B A4 IRH67C30 ER61055B A4 IRH67C30 ER61055B A4 IRH67C30 ER61055B A4 IRH67C30 ER61055B A5 IRH67C30 ER61055B A5 IRH67C30 ER61055B B1 IRH67C30 ER61055C B1 IRH67C30 ER61055C B2 IRH67C30 ER61055C B2 IRH67C30 ER61055C B2 IRH67C30 ER61055C B2 IRH67C30 ER61055C B2 IRH67C30 ER61055C B3 IRH67C30 ER61055C B3 IRH67C30 ER61055C B3 IRH67C30 ER61055C B3 IRH67C30 ER61055C B4 IRH67C30 ER61055C B4 IRH67C30 ER61055C B4 IRH67C30 ER61055C B4 IRH67C30 ER61055C B5 IRH67C30 ER61055C B5 IRH67C30 ER61055C B5 IRH67C30 ER61055C B6 IRH67C30 ER61055C B6 IRH67C30 ER61055C B6 IRH67C30 ER61055C B6 IRH67C30 ER61055C B6 IRH67C30 ER61055C B6 IRH67C30 ER61055C B6 IRH67C30 ER61055C B6 IRH67C30 ER61055C International Rectifier Corp. SEE Test Report March 2006 – T.A.M.U. 0 0 0 0 0 -5 -5 -5 -5 -10 -10 -10 -10 -10 -10 -15 -15 -15 -15 -20 -20 0 0 -5 -5 -5 -5 -5 -10 -10 -10 -10 -15 -15 -15 -15 -20 -20 -20 -15 -16 -17 -18 -19 -20 -21 -22 VGS Volts 580 590 600 610 620 580 590 600 610 580 590 600 610 620 630 580 590 600 610 590 600 600 610 580 590 600 610 620 580 590 600 610 580 590 600 610 590 600 610 600 600 600 600 600 600 600 600 VDS Volts F F F F F F F F F F Pass/Fail Blank=Pass SEE Facility Run # Ion 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 679 679 679 679 679 679 679 679 679 679 679 679 679 679 679 679 679 679 679 679 679 679 679 679 679 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 LET Energy Range Flux 2 2 µm MeV.cm /mg MeV #/cm /sec 600V, Size-3, N, MR, R6-MidVoltage to Krypton Kr 27.2 3/23/2006 TAMU 48 Kr 3/23/2006 TAMU 49 27.2 Kr 3/23/2006 TAMU 50 27.2 Kr 3/23/2006 TAMU 51 27.2 Kr 3/23/2006 TAMU 52 27.2 Kr 3/23/2006 TAMU 53 27.2 Kr 3/23/2006 TAMU 54 27.2 Kr 3/23/2006 TAMU 55 27.2 Kr 3/23/2006 TAMU 56 27.2 Kr 3/23/2006 TAMU 57 27.2 Kr 3/23/2006 TAMU 58 27.2 Kr 3/23/2006 TAMU 59 27.2 Kr 3/23/2006 TAMU 60 27.2 Kr 3/23/2006 TAMU 61 27.2 Kr 3/23/2006 TAMU 62 27.2 Kr 3/23/2006 TAMU 63 27.2 Kr 3/23/2006 TAMU 64 27.2 Kr 3/23/2006 TAMU 65 27.2 Kr 3/23/2006 TAMU 66 27.2 Kr 3/23/2006 TAMU 67 27.2 Kr 3/23/2006 TAMU 68 27.2 600V, Size-3, N, MR, R6-MidVoltage to Krypton Kr 32.4 3/23/2006 TAMU 69 Kr 3/23/2006 TAMU 70 32.4 Kr 3/23/2006 TAMU 71 32.4 Kr 3/23/2006 TAMU 72 32.4 Kr 3/23/2006 TAMU 73 32.4 Kr 3/23/2006 TAMU 74 32.4 Kr 3/23/2006 TAMU 75 32.4 Kr 3/23/2006 TAMU 76 32.4 Kr 3/23/2006 TAMU 77 32.4 Kr 3/23/2006 TAMU 78 32.4 Kr 3/23/2006 TAMU 79 32.4 Kr 3/23/2006 TAMU 80 32.4 Kr 3/23/2006 TAMU 81 32.4 Kr 3/23/2006 TAMU 82 32.4 Kr 3/23/2006 TAMU 83 32.4 Kr 32.4 3/23/2006 TAMU 84 Kr 3/23/2006 TAMU 85 32.4 Kr 3/23/2006 TAMU 86 32.4 Kr 3/23/2006 TAMU 87 32.4 Kr 3/23/2006 TAMU 88 32.4 Kr 3/23/2006 TAMU 89 32.4 Kr 3/23/2006 TAMU 90 32.4 Kr 3/23/2006 TAMU 91 32.4 Kr 3/23/2006 TAMU 92 32.4 Kr 3/23/2006 TAMU 93 32.4 Test Date 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 Fluence 2 #/cm 11 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 Angle BeamDia. deg cm. Device Type Wafer Lot No. DUT ID 1 2 3 4 4 4 4 4 5 5 6 6 6 6 7 8 9 10 10 11 11 11 11 12 12 12 13 13 13 14 14 14 14 15 15 15 15 16 16 16 16 17 17 17 17 17 Socket # Wafer Lot ER61055, Split B, C & D B6 IRH67C30 ER61055C C1 IRH67C30 ER61055D C1 IRH67C30 ER61055D C1 IRH67C30 ER61055D C2 IRH67C30 ER61055D C2 IRH67C30 ER61055D C2 IRH67C30 ER61055D C2 IRH67C30 ER61055D C3 IRH67C30 ER61055D C3 IRH67C30 ER61055D C3 IRH67C30 ER61055D C3 IRH67C30 ER61055D C4 IRH67C30 ER61055D C4 IRH67C30 ER61055D C4 IRH67C30 ER61055D C4 IRH67C30 ER61055D C5 IRH67C30 ER61055D C5 IRH67C30 ER61055D C5 IRH67C30 ER61055D C5 IRH67C30 ER61055D C5 IRH67C30 ER61055D Wafer Lot ER61055, Split B, C & D IRH67C30 ER61055B A7 IRH67C30 ER61055B A8 IRH67C30 ER61055B A9 IRH67C30 ER61055B A10 IRH67C30 ER61055B A10 IRH67C30 ER61055B A10 IRH67C30 ER61055B A10 IRH67C30 ER61055B A10 IRH67C30 ER61055B A11 IRH67C30 ER61055B A11 IRH67C30 ER61055B A12 IRH67C30 ER61055B A12 IRH67C30 ER61055B A12 IRH67C30 ER61055B A12 IRH67C30 ER61055C B7 IRH67C30 ER61055C B8 IRH67C30 ER61055C B9 IRH67C30 ER61055C B10 IRH67C30 ER61055C B10 IRH67C30 ER61055C B11 IRH67C30 ER61055C B11 IRH67C30 ER61055C B11 IRH67C30 ER61055C B11 IRH67C30 ER61055C B12 IRH67C30 ER61055C B12 International Rectifier Corp. SEE Test Report March 2006 – T.A.M.U. -20 -20 -20 -22 -24 -26 -28 -30 -28 -30 -28 -29 -30 -31 -20 -20 -20 -26 -27 -25 -26 -27 -28 -25 -26 -23 0 0 0 -5 -5 -5 -5 -10 -10 -10 -10 -15 -15 -15 -15 -20 -20 -20 -20 -20 VGS Volts 600 600 600 600 600 600 600 600 450 450 300 300 300 300 600 600 600 600 600 450 450 450 450 300 300 600 600 610 620 600 610 620 630 600 610 620 630 590 600 610 620 590 600 610 620 630 VDS Volts F F F F F F Curve-Point Curve-Point Curve-Point Curve-Point Curve-Point Curve-Point Pass/Fail Blank=Pass SEE Facility Run # Ion 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 679 679 679 679 679 679 679 679 679 679 679 679 679 679 679 679 679 679 679 679 679 679 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 LET Energy Range Flux 2 2 µm MeV.cm /mg MeV #/cm /sec 600V, Size-3, N, MR, R6-MidVoltage to Krypton Kr 32.4 3/23/2006 TAMU 94 Kr 3/23/2006 TAMU 95 32.4 Kr 3/23/2006 TAMU 96 32.4 Kr 3/23/2006 TAMU 97 32.4 Kr 3/23/2006 TAMU 98 32.4 Kr 3/23/2006 TAMU 99 32.4 Kr 3/23/2006 TAMU 100 32.4 Kr 3/23/2006 TAMU 101 32.4 Kr 3/23/2006 TAMU 102 32.4 Kr 3/23/2006 TAMU 103 32.4 Kr 3/23/2006 TAMU 104 32.4 Kr 3/23/2006 TAMU 105 32.4 Kr 3/23/2006 TAMU 106 32.4 Kr 3/23/2006 TAMU 107 32.4 Kr 3/23/2006 TAMU 108 32.4 Kr 3/23/2006 TAMU 109 32.4 Kr 3/23/2006 TAMU 110 32.4 Kr 3/23/2006 TAMU 111 32.4 Kr 3/23/2006 TAMU 112 32.4 Kr 3/23/2006 TAMU 113 32.4 Kr 3/23/2006 TAMU 114 32.4 Kr 3/23/2006 TAMU 115 32.4 600V, Size-3, N, MR, R6-MidVoltage to Xenon Xe 56.2 3/23/2006 TAMU 353 Xe 3/23/2006 TAMU 354 56.2 Xe 3/23/2006 TAMU 355 56.2 Xe 3/23/2006 TAMU 356 56.2 Xe 3/23/2006 TAMU 357 56.2 Xe 3/23/2006 TAMU 358 56.2 Xe 3/23/2006 TAMU 359 56.2 Xe 3/23/2006 TAMU 360 56.2 Xe 3/23/2006 TAMU 361 56.2 Xe 3/23/2006 TAMU 362 56.2 Xe 3/23/2006 TAMU 363 56.2 Xe 3/23/2006 TAMU 364 56.2 Xe 3/23/2006 TAMU 365 56.2 Xe 3/23/2006 TAMU 366 56.2 Xe 3/23/2006 TAMU 367 56.2 Xe 3/23/2006 TAMU 368 56.2 Xe 3/23/2006 TAMU 369 56.2 Xe 3/23/2006 TAMU 370 56.2 Xe 3/23/2006 TAMU 371 56.2 Xe 3/23/2006 TAMU 372 56.2 Xe 3/23/2006 TAMU 373 56.2 Xe 3/23/2006 TAMU 374 56.2 Xe 3/23/2006 TAMU 375 56.2 Xe 3/23/2006 TAMU 376 56.2 Test Date 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 Fluence 2 #/cm 12 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 Angle BeamDia. deg cm. Device Type Wafer Lot No. DUT ID 1 1 1 2 2 2 2 3 3 3 4 4 4 5 5 5 5 5 5 5 5 5 5 5 12 12 12 12 13 14 15 16 16 17 17 17 17 17 17 17 18 18 18 18 18 18 Socket # Wafer Lot ER61055, Split B, C & D IRH67C30 ER61055C B12 IRH67C30 ER61055C B12 IRH67C30 ER61055C B12 IRH67C30 ER61055C B12 IRH67C30 ER61055D C6 IRH67C30 ER61055D C2 IRH67C30 ER61055D C3 C4 IRH67C30 ER61055D C4 IRH67C30 ER61055D C5 IRH67C30 ER61055D C5 IRH67C30 ER61055D C5 IRH67C30 ER61055D C5 IRH67C30 ER61055D C5 IRH67C30 ER61055D C5 IRH67C30 ER61055D C5 IRH67C30 ER61055D C6 IRH67C30 ER61055D C6 IRH67C30 ER61055D C6 IRH67C30 ER61055D C6 IRH67C30 ER61055D C6 IRH67C30 ER61055D C6 IRH67C30 ER61055D Wafer Lot ER61055, Split B, C & D IRH67C30 ER61055B A13 IRH67C30 ER61055B A13 IRH67C30 ER61055B A13 IRH67C30 ER61055B A14 IRH67C30 ER61055B A14 IRH67C30 ER61055B A14 IRH67C30 ER61055B A14 IRH67C30 ER61055B A15 IRH67C30 ER61055B A15 IRH67C30 ER61055B A15 IRH67C30 ER61055B A16 IRH67C30 ER61055B A16 IRH67C30 ER61055B A16 IRH67C30 ER61055B A17 IRH67C30 ER61055B A17 IRH67C30 ER61055B A17 IRH67C30 ER61055B A17 IRH67C30 ER61055B A17 IRH67C30 ER61055B A17 IRH67C30 ER61055B A17 IRH67C30 ER61055B A17 IRH67C30 ER61055B A17 IRH67C30 ER61055B A17 IRH67C30 ER61055B A17 International Rectifier Corp. SEE Test Report March 2006 – T.A.M.U. -10 -12 -14 -10 -12 -14 -16 -12 -14 -16 -12 -14 -16 -12 -14 -16 -18 -20 -22 -24 -20 -20 -20 -20 -27 -28 -29 -30 -20 -20 -20 -25 -26 -24 -26 -27 -28 -29 -30 -31 0 0 0 0 0 0 VGS Volts 600 600 600 450 450 450 450 300 300 300 150 150 150 0 0 0 0 0 0 0 50 60 70 80 300 300 300 300 600 600 600 600 600 450 450 450 450 450 450 450 600 605 610 615 620 625 VDS Volts F F F F F Curve-Point Curve-Point Curve-Point Pass/Fail Blank=Pass SEE Facility Run # Ion 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 LET Energy Range Flux 2 2 µm MeV.cm /mg MeV #/cm /sec 600V, Size-3, N, MR, R6-MidVoltage to Xenon Xe 3/23/2006 TAMU 377 56.2 Xe 3/23/2006 TAMU 378 56.2 Xe 3/23/2006 TAMU 379 56.2 Xe 3/23/2006 TAMU 380 56.2 Xe 3/23/2006 TAMU 381 56.2 Xe 3/23/2006 TAMU 382 56.2 Xe 3/23/2006 TAMU 383 56.2 Xe 3/23/2006 TAMU 384 56.2 Xe 3/23/2006 TAMU 385 56.2 Xe 3/23/2006 TAMU 386 56.2 Xe 3/23/2006 TAMU 387 56.2 Xe 3/23/2006 TAMU 388 56.2 Xe 3/23/2006 TAMU 389 56.2 Xe 3/23/2006 TAMU 390 56.2 Xe 3/23/2006 TAMU 391 56.2 Xe 3/23/2006 TAMU 392 56.2 Xe 3/23/2006 TAMU 393 56.2 Xe 3/23/2006 TAMU 394 56.2 Xe 3/23/2006 TAMU 395 56.2 Xe 3/23/2006 TAMU 396 56.2 Xe 3/23/2006 TAMU 397 56.2 Xe 3/23/2006 TAMU 398 56.2 Xe 3/23/2006 TAMU 399 56.2 Xe 3/23/2006 TAMU 400 56.2 Xe 3/23/2006 TAMU 401 56.2 Xe 3/23/2006 TAMU 402 56.2 Xe 3/23/2006 TAMU 403 56.2 Xe 3/23/2006 TAMU 404 56.2 Xe 3/23/2006 TAMU 405 56.2 Xe 3/23/2006 TAMU 406 56.2 Xe 3/23/2006 TAMU 407 56.2 Xe 3/23/2006 TAMU 408 56.2 Xe 3/23/2006 TAMU 409 56.2 Xe 3/23/2006 TAMU 410 56.2 Xe 3/23/2006 TAMU 411 56.2 Xe 3/23/2006 TAMU 412 56.2 Xe 3/23/2006 TAMU 413 56.2 Xe 3/23/2006 TAMU 414 56.2 Xe 3/23/2006 TAMU 415 56.2 Xe 3/23/2006 TAMU 416 56.2 Xe 3/23/2006 TAMU 417 56.2 Xe 3/23/2006 TAMU 418 56.2 Xe 3/23/2006 TAMU 419 56.2 Xe 3/23/2006 TAMU 420 56.2 Xe 3/23/2006 TAMU 421 56.2 Xe 3/23/2006 TAMU 422 56.2 Xe 3/23/2006 TAMU 423 56.2 Test Date 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 Fluence 2 #/cm 13 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 Angle BeamDia. deg cm. Device Type Wafer Lot No. DUT ID 5 5 6 6 6 6 7 7 7 7 7 8 8 8 9 9 9 9 10 10 10 11 12 12 12 12 12 13 13 13 14 14 14 15 15 15 16 16 16 17 17 17 18 18 18 18 1 Socket # Wafer Lot ER61055, Split B, C & D IRH67C30 ER61055B A17 IRH67C30 ER61055B A17 IRH67C30 ER61055B A18 IRH67C30 ER61055B A18 IRH67C30 ER61055B A18 IRH67C30 ER61055B A18 IRH67C30 ER61055C B13 IRH67C30 ER61055C B13 IRH67C30 ER61055C B13 IRH67C30 ER61055C B13 IRH67C30 ER61055C B13 IRH67C30 ER61055C B14 IRH67C30 ER61055C B14 IRH67C30 ER61055C B14 IRH67C30 ER61055C B15 IRH67C30 ER61055C B15 IRH67C30 ER61055C B15 IRH67C30 ER61055C B15 IRH67C30 ER61055C B16 IRH67C30 ER61055C B16 IRH67C30 ER61055C B16 IRH67C30 ER61055C B17 IRH67C30 ER61055C B18 IRH67C30 ER61055C B18 IRH67C30 ER61055C B18 IRH67C30 ER61055C B18 IRH67C30 ER61055C B18 IRH67C30 ER61055D C13 IRH67C30 ER61055D C13 IRH67C30 ER61055D C13 IRH67C30 ER61055D C14 IRH67C30 ER61055D C14 IRH67C30 ER61055D C14 IRH67C30 ER61055D C15 IRH67C30 ER61055D C15 IRH67C30 ER61055D C15 IRH67C30 ER61055D C16 IRH67C30 ER61055D C16 IRH67C30 ER61055D C16 IRH67C30 ER61055D C17 IRH67C30 ER61055D C17 IRH67C30 ER61055D C17 IRH67C30 ER61055D C18 IRH67C30 ER61055D C18 IRH67C30 ER61055D C18 IRH67C30 ER61055D C18 IRH67C30 ER61055B A19 International Rectifier Corp. SEE Test Report March 2006 – T.A.M.U. -20 -20 0 0 0 0 -10 -12 -14 -16 -18 -12 -14 -16 -10 -12 -14 -15 -10 -12 -14 0 -20 -20 -20 -20 -20 -12 -14 -16 -12 -14 -16 -12 -14 -15 -10 -12 -14 0 0 0 -20 -20 -20 -20 -12 VGS Volts 90 100 600 605 610 615 150 150 150 150 150 300 300 300 450 450 450 450 600 600 600 600 50 70 80 90 100 150 150 150 300 300 300 450 450 450 600 600 600 600 605 610 50 60 70 80 600 VDS Volts F F F F F F F F F F F F Curve-Point F (SEB) F Pass/Fail Blank=Pass SEE Facility Run # Ion 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 100.7 100.7 100.7 100.7 100.7 100.7 100.7 100.7 56.4 56.4 56.4 56.4 56.4 56.4 56.4 56.4 56.4 56.4 56.4 56.4 46.5 46.5 46.5 46.5 46.5 46.5 46.5 46.5 99 99 99 99 99 99 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1279 1279 1279 1279 1279 1279 1279 1279 693 693 693 693 693 693 693 693 693 693 693 693 553 553 553 553 553 553 553 553 1863 1863 1863 1863 1863 1863 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 LET Energy Range Flux 2 2 µm MeV.cm /mg MeV #/cm /sec 600V, Size-3, N, MR, R6-MidVoltage to Xenon Xe 3/23/2006 TAMU 424 56.2 Xe 3/23/2006 TAMU 425 56.2 Xe 3/23/2006 TAMU 426 56.2 Xe 3/23/2006 TAMU 427 56.2 Xe 3/23/2006 TAMU 428 56.2 Xe 3/23/2006 TAMU 429 56.2 Xe 3/23/2006 TAMU 430 56.2 Xe 3/23/2006 TAMU 431 56.2 Xe 3/23/2006 TAMU 432 56.2 Xe 3/23/2006 TAMU 433 56.2 Xe 3/23/2006 TAMU 434 56.2 Xe 3/23/2006 TAMU 435 56.2 Xe 3/23/2006 TAMU 436 53.7 Xe 3/23/2006 TAMU 437 53.7 Xe 3/23/2006 TAMU 438 53.7 Xe 3/23/2006 TAMU 439 53.7 Xe 3/23/2006 TAMU 440 53.7 Xe 3/23/2006 TAMU 441 53.7 Xe 3/23/2006 TAMU 442 53.7 Xe 3/23/2006 TAMU 443 53.7 Xe 60.5 3/23/2006 TAMU 444 Xe 3/23/2006 TAMU 445 60.5 Xe 3/23/2006 TAMU 446 60.5 Xe 3/23/2006 TAMU 447 60.5 Xe 3/23/2006 TAMU 448 60.5 Xe 3/23/2006 TAMU 449 60.5 Xe 3/23/2006 TAMU 450 60.5 Xe 3/23/2006 TAMU 451 60.5 Xe 3/23/2006 TAMU 452 60.5 Xe 3/23/2006 TAMU 453 60.5 Xe 3/23/2006 TAMU 454 60.5 Xe 3/23/2006 TAMU 455 60.5 Xe 62 3/23/2006 TAMU 456 Xe 3/23/2006 TAMU 457 62 Xe 3/23/2006 TAMU 458 62 Xe 3/23/2006 TAMU 459 62 Xe 3/23/2006 TAMU 460 62 Xe 3/23/2006 TAMU 461 62 Xe 3/23/2006 TAMU 462 62 Xe 3/23/2006 TAMU 463 62 600V, Size-3, N, MR, R6-MidVoltage to Gold Au 87.5 3/23/2006 TAMU 678 Au 3/23/2006 TAMU 679 87.5 Au 3/23/2006 TAMU 680 87.5 Au 3/23/2006 TAMU 681 87.5 Au 3/23/2006 TAMU 682 87.5 Au 3/23/2006 TAMU 683 87.5 Test Date 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 Fluence 2 #/cm 14 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 Angle BeamDia. deg cm. Device Type Wafer Lot No. DUT ID 1 1 1 1 1 1 2 3 7 8 8 9 10 11 12 13 14 15 16 16 16 16 16 4 4 4 5 5 5 5 5 5 5 17 17 17 17 17 18 18 18 18 18 18 6 6 Socket # Wafer Lot ER61055, Split B, C & D IRH67C30 ER61055B A20 IRH67C30 ER61055B A21 IRH67C30 ER61055C B19 IRH67C30 ER61055C B20 IRH67C30 ER61055C B20 IRH67C30 ER61055C B21 IRH67C30 ER61055C B22 IRH67C30 ER61055C B23 IRH67C30 ER61055C B24 IRH67C30 ER61055D C19 IRH67C30 ER61055D C20 IRH67C30 ER61055D C21 IRH67C30 ER61055D C22 IRH67C30 ER61055D C22 IRH67C30 ER61055D C22 IRH67C30 ER61055D C22 IRH67C30 ER61055D C22 IRH67C30 ER61055B A22 IRH67C30 ER61055B A22 IRH67C30 ER61055B A22 IRH67C30 ER61055B A23 IRH67C30 ER61055B A23 IRH67C30 ER61055B A23 IRH67C30 ER61055B A23 IRH67C30 ER61055B A23 IRH67C30 ER61055B A23 IRH67C30 ER61055B A23 IRH67C30 ER61055D C23 IRH67C30 ER61055D C23 IRH67C30 ER61055D C23 IRH67C30 ER61055D C23 IRH67C30 ER61055D C23 IRH67C30 ER61055D C24 IRH67C30 ER61055D C24 IRH67C30 ER61055D C24 IRH67C30 ER61055D C24 IRH67C30 ER61055D C24 IRH67C30 ER61055D C24 IRH67C30 ER61055B A24 IRH67C30 ER61055B A24 Wafer Lot ER61055, Split B, C & D IRH67C30 ER61055B A25 IRH67C30 ER61055B A25 IRH67C30 ER61055B A25 IRH67C30 ER61055B A25 IRH67C30 ER61055B A25 IRH67C30 ER61055B A25 International Rectifier Corp. SEE Test Report March 2006 – T.A.M.U. 0 0 0 0 0 0 -12 -12 -12 -10 -10 -8 -6 -6 -6 -12 -12 -12 -10 -12 -14 -15 -16 -10 -12 -14 -10 -11 -12 -13 -14 -15 -16 -12 -13 -14 -15 -16 -12 -13 -14 -15 -16 -17 -12 -13 VGS Volts 200 250 300 350 400 450 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 VDS Volts F F F F F F F F F F Curve-Point Curve-Point Curve-Point Curve-Point<-6V Curve-Point<-6V Curve-Point Curve-Point Pass/Fail Blank=Pass SEE Facility Run # Ion 1863 1863 1863 1863 1555 1555 1555 1555 1017 1017 1017 1017 1017 1017 1555 1555 1555 1555 1555 1555 1555 1555 1555 1555 1555 1555 1555 1555 1555 1555 1555 1555 1555 1555 99 99 99 99 84 84 84 84 58.6 58.6 58.6 58.6 58.6 58.6 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 2.00E+04 LET Energy Range Flux 2 2 µm #/cm /sec MeV.cm /mg MeV 600V, Size-3, N, MR, R6-MidVoltage to Gold Au 3/23/2006 TAMU 684 87.5 Au 3/23/2006 TAMU 685 87.5 Au 3/23/2006 TAMU 686 87.5 Au 3/23/2006 TAMU 687 87.5 Au 89.5 3/23/2006 TAMU 688 Au 3/23/2006 TAMU 689 89.5 Au 3/23/2006 TAMU 690 89.5 Au 3/23/2006 TAMU 691 89.5 Au 93.4 3/23/2006 TAMU 692 Au 3/23/2006 TAMU 693 93.4 Au 3/23/2006 TAMU 694 93.4 Au 3/23/2006 TAMU 695 93.4 Au 3/23/2006 TAMU 696 93.4 Au 3/23/2006 TAMU 697 93.4 Au 89.5 3/23/2006 TAMU 698 Au 3/23/2006 TAMU 699 89.5 Au 3/23/2006 TAMU 700 89.5 Au 3/23/2006 TAMU 701 89.5 Au 3/23/2006 TAMU 702 89.5 Au 3/23/2006 TAMU 703 89.5 Au 3/23/2006 TAMU 704 89.5 Au 3/23/2006 TAMU 705 89.5 Au 3/23/2006 TAMU 706 89.5 Au 3/23/2006 TAMU 707 89.5 Au 3/23/2006 TAMU 708 89.5 Au 3/23/2006 TAMU 709 89.5 Au 3/23/2006 TAMU 710 89.5 Au 3/23/2006 TAMU 711 89.5 Au 3/23/2006 TAMU 712 89.5 Au 3/23/2006 TAMU 713 89.5 Au 3/23/2006 TAMU 714 89.5 Au 3/23/2006 TAMU 715 89.5 Au 3/23/2006 TAMU 716 89.5 Au 3/23/2006 TAMU 717 89.5 Test Date 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 3.00E+05 Fluence 2 #/cm 15 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 2.0 x 2.0 Angle BeamDia. deg cm. Device Type Wafer Lot No. DUT ID 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 2 2 3 4 5 6 12 12 13 13 14 15 16 14 7 8 Socket # Wafer Lot ER61055, Split B, C & D IRH67C30 ER61055B A25 IRH67C30 ER61055B A25 IRH67C30 ER61055B A25 IRH67C30 ER61055B A25 IRH67C30 ER61055B A25 IRH67C30 ER61055B A25 IRH67C30 ER61055B A25 IRH67C30 ER61055B A25 IRH67C30 ER61055B A26 IRH67C30 ER61055B A26 IRH67C30 ER61055B A26 IRH67C30 ER61055B A26 IRH67C30 ER61055B A26 IRH67C30 ER61055B A26 IRH67C30 ER61055B A26 IRH67C30 ER61055B A26 IRH67C30 ER61055B A26 IRH67C30 ER61055B A26 IRH67C30 ER61055B A26 IRH67C30 ER61055B A26 IRH67C30 ER61055B A27 IRH67C30 ER61055B A28 IRH67C30 ER61055B A29 IRH67C30 ER61055B A30 IRH67C30 ER61055D C25 IRH67C30 ER61055D C25 IRH67C30 ER61055D C26 IRH67C30 ER61055D C26 IRH67C30 ER61055D C27 IRH67C30 ER61055D C28 IRH67C30 ER61055D C29 IRH67C30 ER61055D C27 IRH67C30 ER61055C B25 IRH67C30 ER61055C B26 International Rectifier Corp. SEE Test Report March 2006 – T.A.M.U. 0 0 0 0 0 0 0 0 0 0 0 0 -1 -2 -1 -2 -3 -4 -5 -6 -5 -4 -4 -3 -3 -4 -3 -4 -4 -5 -5 -5 -1 -5 VGS Volts 500 550 600 610 580 590 600 610 580 590 600 610 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 400 VDS Volts F F F F F F Curve-Point (-4V) Curve-Point (-4V) Curve-Point Curve-Point Invalid_GateStress Pass/Fail Blank=Pass International Rectifier Corp. SEE Test Report March 2006 – T.A.M.U. Appendix B TAMU Facility SEE Beam Data 16 Run FileName IR_March_2006.#00 IR_March_2006.#01 IR_March_2006.#02 IR_March_2006.#03 IR_March_2006.#04 IR_March_2006.#05 IR_March_2006.#06 IR_March_2006.#07 IR_March_2006.#08 IR_March_2006.#09 IR_March_2006.#0a IR_March_2006.#0b IR_March_2006.#0c IR_March_2006.#0d IR_March_2006.#0e IR_March_2006.#0f IR_March_2006.#0g IR_March_2006.#0h IR_March_2006.#0i IR_March_2006.#0j IR_March_2006.#0k IR_March_2006.#0l IR_March_2006.#0m IR_March_2006.#0n IR_March_2006.#0o IR_March_2006.#0p IR_March_2006.#0q IR_March_2006.#0r IR_March_2006.#0s IR_March_2006.#0t IR_March_2006.#0u IR_March_2006.#0v IR_March_2006.#0w IR_March_2006.#0x IR_March_2006.#0y IR_March_2006.#0z IR_March_2006.#10 IR_March_2006.#11 IR_March_2006.#12 IR_March_2006.#13 IR_March_2006.#14 IR_March_2006.#15 IR_March_2006.#16 IR_March_2006.#17 IR_March_2006.#18 IR_March_2006.#19 IR_March_2006.#1a IR_March_2006.#1b IR_March_2006.#1c IR_March_2006.#1d IR_March_2006.#1e IR_March_2006.#1f IR_March_2006.#1g IR_March_2006.#1h IR_March_2006.#1i IR_March_2006.#1j IR_March_2006.#1k IR_March_2006.#1l IR_March_2006.#1m IR_March_2006.#1n IR_March_2006.#1o IR_March_2006.#1p IR_March_2006.#1q IR_March_2006.#1r IR_March_2006.#1s IR_March_2006.#1t IR_March_2006.#1u IR_March_2006.#1v IR_March_2006.#1w IR_March_2006.#1x IR_March_2006.#1y IR_March_2006.#1z IR_March_2006.#20 IR_March_2006.#21 IR_March_2006.#22 IR_March_2006.#23 IR_March_2006.#24 IR_March_2006.#25 IR_March_2006.#26 IR_March_2006.#27 IR_March_2006.#28 IR_March_2006.#29 IR_March_2006.#2a IR_March_2006.#2b IR_March_2006.#2c IR_March_2006.#2d IR_March_2006.#2e IR_March_2006.#2f IR_March_2006.#2g IR_March_2006.#2h IR_March_2006.#2i IR_March_2006.#2j IR_March_2006.#2k IR_March_2006.#2l IR_March_2006.#2m IR_March_2006.#2n IR_March_2006.#2o IR_March_2006.#2p IR_March_2006.#2q IR_March_2006.#2r IR_March_2006.#2s IR_March_2006.#2t IR_March_2006.#2u IR_March_2006.#2v IR_March_2006.#2w Run # 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 70 71 72 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 100 101 102 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 Start Date 11:12:49 11:16:01 11:17:53 11:19:49 11:20:35 11:23:20 11:23:58 11:24:50 11:25:27 11:27:07 11:27:56 11:28:31 11:29:05 11:29:39 11:30:27 11:31:24 11:32:12 11:32:44 11:33:19 11:34:28 11:35:10 11:38:00 11:38:36 11:39:46 11:40:19 11:41:13 11:41:56 11:42:33 11:44:46 11:45:24 11:46:01 11:46:35 11:47:38 11:48:40 11:49:20 11:49:56 11:51:31 11:52:18 11:53:02 11:54:25 11:55:07 11:55:42 11:56:18 11:56:55 11:57:33 11:58:16 11:59:36 12:00:10 12:02:23 12:02:59 12:03:40 12:04:56 12:05:35 12:06:07 12:06:43 12:07:48 12:08:29 12:09:06 12:09:43 12:10:44 12:11:18 12:11:54 12:12:29 12:13:31 12:14:06 12:14:46 12:15:26 12:15:58 12:53:10 12:59:13 13:03:17 13:04:53 13:06:35 13:07:45 13:08:22 13:08:59 13:09:36 13:10:11 13:12:12 13:14:54 13:16:39 13:17:20 13:17:57 13:18:36 13:20:52 13:22:39 13:23:50 13:24:59 13:25:37 13:26:45 13:27:15 13:27:49 13:28:22 13:29:55 13:30:37 13:31:13 13:31:48 13:32:24 13:33:05 13:35:09 13:36:20 13:37:54 13:38:47 13:40:16 13:40:53 Start Time 00:00:24_(+_0_days) 00:00:19_(+_0_days) 00:00:16_(+_0_days) 00:00:19_(+_0_days) 00:00:08_(+_0_days) 00:00:19_(+_0_days) 00:00:20_(+_0_days) 00:00:18_(+_0_days) 00:00:08_(+_0_days) 00:00:17_(+_0_days) 00:00:19_(+_0_days) 00:00:17_(+_0_days) 00:00:18_(+_0_days) 00:00:18_(+_0_days) 00:00:08_(+_0_days) 00:00:26_(+_0_days) 00:00:17_(+_0_days) 00:00:22_(+_0_days) 00:00:09_(+_0_days) 00:00:19_(+_0_days) 00:00:10_(+_0_days) 00:00:17_(+_0_days) 00:00:07_(+_0_days) 00:00:18_(+_0_days) 00:00:24_(+_0_days) 00:00:17_(+_0_days) 00:00:18_(+_0_days) 00:00:06_(+_0_days) 00:00:18_(+_0_days) 00:00:19_(+_0_days) 00:00:21_(+_0_days) 00:00:07_(+_0_days) 00:00:17_(+_0_days) 00:00:20_(+_0_days) 00:00:19_(+_0_days) 00:00:16_(+_0_days) 00:00:19_(+_0_days) 00:00:30_(+_0_days) 00:00:07_(+_0_days) 00:00:19_(+_0_days) 00:00:19_(+_0_days) 00:00:18_(+_0_days) 00:00:19_(+_0_days) 00:00:18_(+_0_days) 00:00:19_(+_0_days) 00:00:19_(+_0_days) 00:00:18_(+_0_days) 00:00:18_(+_0_days) 00:00:24_(+_0_days) 00:00:19_(+_0_days) 00:00:13_(+_0_days) 00:00:22_(+_0_days) 00:00:19_(+_0_days) 00:00:19_(+_0_days) 00:00:07_(+_0_days) 00:00:18_(+_0_days) 00:00:23_(+_0_days) 00:00:18_(+_0_days) 00:00:07_(+_0_days) 00:00:18_(+_0_days) 00:00:19_(+_0_days) 00:00:18_(+_0_days) 00:00:07_(+_0_days) 00:00:18_(+_0_days) 00:00:19_(+_0_days) 00:00:21_(+_0_days) 00:00:18_(+_0_days) 00:00:07_(+_0_days) 00:00:20_(+_0_days) 00:00:30_(+_0_days) 00:00:19_(+_0_days) 00:00:19_(+_0_days) 00:00:19_(+_0_days) 00:00:20_(+_0_days) 00:00:18_(+_0_days) 00:00:18_(+_0_days) 00:00:17_(+_0_days) 00:00:08_(+_0_days) 00:00:19_(+_0_days) 00:00:09_(+_0_days) 00:00:18_(+_0_days) 00:00:19_(+_0_days) 00:00:19_(+_0_days) 00:00:07_(+_0_days) 00:00:18_(+_0_days) 00:00:18_(+_0_days) 00:00:18_(+_0_days) 00:00:19_(+_0_days) 00:00:08_(+_0_days) 00:00:18_(+_0_days) 00:00:19_(+_0_days) 00:00:18_(+_0_days) 00:00:07_(+_0_days) 00:00:20_(+_0_days) 00:00:19_(+_0_days) 00:00:21_(+_0_days) 00:00:18_(+_0_days) 00:00:19_(+_0_days) 00:00:20_(+_0_days) 00:00:21_(+_0_days) 00:00:40_(+_0_days) 00:00:22_(+_0_days) 00:00:19_(+_0_days) 00:00:19_(+_0_days) 00:00:18_(+_0_days) Run Duration 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Upset Events 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr Selected Beam 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2.111 2.111 2.111 2.111 2.111 2.111 2.111 2.111 2.111 2.111 2.111 2.111 2.111 2.111 2.111 2.111 2.111 2.111 2.111 2.111 2.111 2.111 2.111 2.111 2.111 2.111 2.111 2.111 2.111 2.111 2.111 2.111 2.111 2.111 2.111 2.111 2.111 ( µm ) Al Thk 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) # of Layers ( Filename ) 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 8.1 8.1 8.1 8.1 8.1 8.1 8.1 8.1 8.1 8.1 8.1 8.1 8.1 8.1 8.1 8.1 8.1 8.1 8.1 8.1 8.1 8.1 8.1 8.1 8.1 8.1 8.1 8.1 8.1 8.1 8.1 8.1 8.1 8.1 8.1 8.1 8.1 (MeV/amu) 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 679 679 679 679 679 679 679 679 679 679 679 679 679 679 679 679 679 679 679 679 679 679 679 679 679 679 679 679 679 679 679 679 679 679 679 679 679 (MeV) Beam Energy silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 32.4 32.4 32.4 32.4 32.4 32.4 32.4 32.4 32.4 32.4 32.4 32.4 32.4 32.4 32.4 32.4 32.4 32.4 32.4 32.4 32.4 32.4 32.4 32.4 32.4 32.4 32.4 32.4 32.4 32.4 32.4 32.4 32.4 32.4 32.4 32.4 32.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 32.4 32.4 32.4 32.4 32.4 32.4 32.4 32.4 32.4 32.4 32.4 32.4 32.4 32.4 32.4 32.4 32.4 32.4 32.4 32.4 32.4 32.4 32.4 32.4 32.4 32.4 32.4 32.4 32.4 32.4 32.4 32.4 32.4 32.4 32.4 32.4 32.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 17 In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air pos_01 pos_01 pos_01 pos_01 pos_01 pos_02 pos_02 pos_02 pos_02 pos_03 pos_03 pos_03 pos_03 pos_03 pos_03 pos_04 pos_04 pos_04 pos_04 pos_05 pos_05 pos_07 pos_07 pos_08 pos_08 pos_08 pos_08 pos_08 pos_09 pos_09 pos_09 pos_09 pos_10 pos_10 pos_10 pos_10 Current Current Current pos_12 pos_12 pos_12 pos_12 pos_12 pos_12 pos_12 pos_12 pos_12 pos_13 pos_13 pos_13 pos_14 pos_14 pos_14 pos_14 pos_15 pos_15 pos_15 pos_15 pos_16 pos_16 pos_16 pos_16 pos_17 pos_17 pos_17 pos_17 pos_17 Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current 3.04E+05 3.09E+05 3.05E+05 3.00E+05 9.22E+04 2.94E+05 2.96E+05 2.94E+05 1.17E+05 3.01E+05 2.94E+05 2.92E+05 3.02E+05 3.11E+05 9.51E+04 3.08E+05 2.94E+05 2.93E+05 1.20E+05 3.04E+05 1.62E+05 3.01E+05 6.79E+04 3.09E+05 3.08E+05 2.94E+05 3.01E+05 4.88E+04 3.06E+05 2.91E+05 2.96E+05 5.83E+04 2.91E+05 3.09E+05 2.88E+05 3.00E+05 3.09E+05 2.98E+05 6.53E+04 3.12E+05 3.10E+05 2.91E+05 2.97E+05 3.00E+05 3.00E+05 3.03E+05 2.91E+05 2.98E+05 3.05E+05 3.04E+05 1.97E+05 3.04E+05 3.03E+05 2.91E+05 6.24E+04 2.89E+05 2.93E+05 2.94E+05 5.50E+04 3.05E+05 3.04E+05 3.05E+05 5.82E+04 2.90E+05 2.98E+05 3.11E+05 2.94E+05 6.26E+04 3.01E+05 3.01E+05 2.88E+05 2.91E+05 3.08E+05 3.07E+05 2.95E+05 3.12E+05 2.99E+05 9.45E+04 3.06E+05 1.08E+05 3.05E+05 2.94E+05 3.05E+05 6.65E+04 3.02E+05 2.98E+05 2.96E+05 3.06E+05 1.11E+05 3.00E+05 2.93E+05 2.90E+05 5.69E+04 2.96E+05 3.01E+05 2.93E+05 2.95E+05 3.09E+05 3.06E+05 3.09E+05 3.04E+05 2.94E+05 3.00E+05 2.97E+05 2.82E+05 Nominal Nominal Effective Effective Effective Target LET Range LET Range DUT Position Fluence 2 (MeV.cm /mg) Material (MeV.cm2/mg) Location Name ( ions/cm2 ) ( µm ) ( µm ) 1.32E+02 1.35E+02 1.33E+02 1.31E+02 4.01E+01 1.28E+02 1.29E+02 1.28E+02 5.07E+01 1.31E+02 1.28E+02 1.27E+02 1.31E+02 1.35E+02 4.14E+01 1.34E+02 1.28E+02 1.28E+02 5.23E+01 1.32E+02 7.05E+01 1.31E+02 2.95E+01 1.35E+02 1.34E+02 1.28E+02 1.31E+02 2.12E+01 1.33E+02 1.26E+02 1.29E+02 2.54E+01 1.27E+02 1.34E+02 1.25E+02 1.31E+02 1.34E+02 1.30E+02 2.84E+01 1.36E+02 1.35E+02 1.27E+02 1.29E+02 1.31E+02 1.30E+02 1.32E+02 1.26E+02 1.29E+02 1.33E+02 1.32E+02 8.57E+01 1.32E+02 1.32E+02 1.27E+02 2.71E+01 1.26E+02 1.27E+02 1.28E+02 2.39E+01 1.33E+02 1.32E+02 1.33E+02 2.53E+01 1.26E+02 1.30E+02 1.35E+02 1.28E+02 2.72E+01 1.56E+02 1.56E+02 1.50E+02 1.51E+02 1.60E+02 1.59E+02 1.53E+02 1.62E+02 1.55E+02 4.90E+01 1.59E+02 5.59E+01 1.59E+02 1.53E+02 1.59E+02 3.45E+01 1.57E+02 1.55E+02 1.54E+02 1.59E+02 5.75E+01 1.56E+02 1.52E+02 1.51E+02 2.96E+01 1.53E+02 1.56E+02 1.52E+02 1.53E+02 1.60E+02 1.59E+02 1.61E+02 1.58E+02 1.53E+02 1.56E+02 1.54E+02 1.46E+02 ( rad ) Dose International Rectifier Corp. SEE Test Report March 2006 – T.A.M.U. Average Flux 0.57 0.57 0.57 0.58 1 0.58 0.58 0.58 0.93 0.58 0.58 0.59 0.58 0.57 1 0.57 0.58 0.58 0.91 0.57 0.79 0.58 1.2 0.57 0.57 0.58 0.58 1.4 0.57 0.59 0.58 1.3 0.59 0.57 0.59 0.58 0.57 0.58 1.2 0.57 0.57 0.59 0.58 0.58 0.58 0.57 0.59 0.58 0.57 0.57 0.71 0.57 0.57 0.59 1.3 0.59 0.58 0.58 1.3 0.57 0.57 0.57 1.3 0.59 0.58 0.57 0.58 1.3 0.58 0.58 0.59 0.59 0.57 0.57 0.58 0.57 0.58 1 0.57 0.96 0.57 0.58 0.57 1.2 0.58 0.58 0.58 0.57 0.95 0.58 0.58 0.59 1.3 0.58 0.58 0.58 0.58 0.57 0.57 0.57 0.57 0.58 0.58 0.58 0.6 76 79 79 79 81 77 79 80 80 82 82 79 79 79 79 82 81 80 81 77 80 84 82 82 83 82 81 80 81 81 73 74 79 83 83 82 80 76 80 81 79 80 78 81 81 82 81 80 78 80 79 79 79 80 80 82 81 82 82 81 80 82 82 83 82 81 81 80 81 81 81 81 81 81 81 81 81 80 80 80 81 81 81 80 81 81 81 81 80 81 81 80 81 80 80 81 81 81 80 80 81 81 81 80 80 20 17 16 16 14 18 17 15 15 13 14 16 17 16 16 13 15 15 14 18 15 12 13 13 12 13 14 16 14 14 23 22 17 12 12 13 16 19 15 15 16 16 17 15 14 13 14 15 17 15 16 16 16 16 14 13 13 13 12 14 15 13 12 12 13 15 14 14 12 13 12 12 12 12 12 12 12 12 13 13 12 12 12 12 12 13 13 12 10 12 12 13 12 13 13 12 13 13 13 13 12 11 12 13 13 1.31358 1.31537 1.25044 1.22304 1.19628 1.2592 1.2964 1.22916 1.24833 1.24493 1.19479 1.21512 1.24292 1.22674 1.2388 1.21977 1.23729 1.21145 1.21925 1.22893 1.30853 1.2641 1.18453 1.17807 1.16518 1.15762 1.16969 1.18962 1.18695 1.16813 1.24665 1.35116 1.27385 1.14979 1.13793 1.19769 1.21114 1.25917 1.21268 1.25025 1.22779 1.1961 1.23302 1.2309 1.19987 1.17247 1.20663 1.21212 1.22559 1.18791 1.27057 1.2255 1.22924 1.24555 1.2464 1.21256 1.23276 1.27803 1.23232 1.19522 1.24501 1.26166 1.24268 1.2494 1.22178 1.23665 1.23674 1.2242 1.21038 1.23197 1.21947 1.26367 1.2361 1.22703 1.24163 1.22952 1.25387 1.24174 1.27438 1.24471 1.25878 1.23819 1.25177 1.26266 1.23103 1.24853 1.27409 1.26283 1.2679 1.26671 1.2287 1.23093 1.24361 1.24859 1.25491 1.25608 1.24361 1.26026 1.23578 1.24277 1.25114 1.22855 1.26145 1.26136 1.24949 Overall AvgFlux Overall Central Error Uniformity Shift Calibration 2 (%) (%) (%) Factor ( sec.) ( ions/(cm s) ) Dead Time 12.6 0 2.41E+04 12.0667 0 2.56E+04 12.6 0 2.42E+04 12.4 0 2.42E+04 4.21667 0 2.19E+04 12.4833 0 2.35E+04 11.9 0 2.48E+04 12.2667 0 2.40E+04 5.18333 0 2.25E+04 12.45 0 2.42E+04 12.7333 0 2.31E+04 12.6333 0 2.31E+04 12.8333 0 2.35E+04 13.1167 0 2.37E+04 4.4 0 2.16E+04 12.8667 0 2.40E+04 12.4667 0 2.36E+04 14.4667 1 2.03E+04 5.26667 0 2.28E+04 13.65 0 2.23E+04 6.86667 0 2.36E+04 11.8167 0 2.54E+04 3.3 0 2.06E+04 13.2667 0 2.33E+04 13.2667 0 2.32E+04 12.85 0 2.29E+04 13.3333 0 2.26E+04 2.53333 0 1.92E+04 13.4 0 2.28E+04 12.95 0 2.24E+04 13.8167 0 2.14E+04 2.83333 0 2.06E+04 12.6167 0 2.31E+04 13.9167 0 2.22E+04 13 0 2.22E+04 12.8833 0 2.33E+04 13.7 0 2.25E+04 13.2 0 2.26E+04 3.23333 0 2.02E+04 13.15 0 2.37E+04 13.65 0 2.27E+04 13.1833 0 2.21E+04 13.3667 0 2.22E+04 13.1167 0 2.29E+04 13.25 0 2.26E+04 13.55 0 2.24E+04 12.9 0 2.25E+04 13.3 0 2.24E+04 16.1667 0.98333 1.89E+04 14.3833 0 2.11E+04 8.86667 0 2.22E+04 13.9667 0 2.18E+04 13.8333 0 2.19E+04 13 0 2.24E+04 3.16667 0 1.97E+04 13.4667 0 2.15E+04 13.2667 0 2.21E+04 13.1333 0 2.24E+04 2.8 0 1.97E+04 14.2833 0 2.14E+04 13.8 0 2.20E+04 13.5167 0 2.25E+04 2.96667 0 1.96E+04 12.8333 0 2.26E+04 13.9 0 2.15E+04 15.9333 1 1.95E+04 13.7167 0 2.14E+04 3.33333 0 1.88E+04 12.6167 0 2.39E+04 12.7 0 2.37E+04 12.7333 0 2.27E+04 12.3333 0 2.36E+04 13.4333 0 2.29E+04 13.5167 0 2.27E+04 13.0333 0 2.26E+04 13.5833 0 2.29E+04 12.7667 0 2.34E+04 4.38333 0 2.16E+04 13.4833 0 2.27E+04 5.03333 0 2.14E+04 13.4667 0 2.27E+04 13.3667 0 2.20E+04 13.5667 0 2.25E+04 3.28333 0 2.03E+04 13.6 0 2.22E+04 13.3667 0 2.23E+04 13.2 0 2.25E+04 13.5333 0 2.26E+04 5.05 0 2.20E+04 13.6667 0 2.20E+04 14.0333 0 2.09E+04 13.7667 0 2.11E+04 3.01667 0 1.89E+04 13.8333 0 2.14E+04 14.2167 0 2.11E+04 15.5333 1 1.88E+04 13.8833 0 2.13E+04 14.6667 0 2.11E+04 14.5 0 2.11E+04 14.9 0 2.08E+04 14.4167 0 2.11E+04 15.0167 2 1.96E+04 14.3833 0 2.09E+04 14.5333 0 2.04E+04 14.1333 0 2.00E+04 ( sec.) Live Time -3.844 -3.844 -3.844 -3.844 -3.844 -2.244 -2.244 -2.244 -2.244 -0.657 -0.657 -0.657 -0.657 -0.657 -0.657 0.955 0.955 0.955 0.955 2.543 2.543 -3.87 -3.87 -2.27 -2.27 -2.27 -2.27 -2.27 -0.683 -0.683 -0.683 -0.683 0.931 0.931 0.931 0.931 2.531 2.531 2.531 4.119 4.119 4.119 4.119 4.119 4.119 4.119 4.119 4.119 -3.894 -3.894 -3.894 -2.307 -2.307 -2.307 -2.307 -0.707 -0.707 -0.707 -0.707 0.881 0.881 0.881 0.881 2.494 2.494 2.494 2.494 2.494 -3.844 -3.844 -2.244 -0.657 0.955 0.955 0.955 0.955 0.955 0.955 2.543 2.543 4.142 4.142 4.142 4.142 -3.87 -2.27 -0.683 0.931 0.931 2.531 2.531 2.531 2.531 4.119 4.119 4.119 4.119 4.119 4.119 -3.894 -2.307 -0.707 -0.707 0.881 0.881 -2.443 -2.443 -2.443 -2.443 -2.443 -2.418 -2.418 -2.418 -2.418 -2.393 -2.393 -2.393 -2.393 -2.393 -2.393 -2.393 -2.393 -2.393 -2.393 -2.343 -2.343 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 0.046 0.046 0.046 0.072 0.072 0.072 0.072 0.072 0.072 0.072 0.072 0.072 2.384 2.384 2.384 2.384 2.384 2.384 2.384 2.433 2.433 2.433 2.433 2.433 2.433 2.433 2.433 2.483 2.483 2.483 2.483 2.483 -2.443 -2.443 -2.418 -2.393 -2.393 -2.393 -2.393 -2.393 -2.393 -2.393 -2.343 -2.343 -2.343 -2.343 -2.343 -2.343 -0.003 -0.003 -0.003 -0.003 -0.003 0.046 0.046 0.046 0.046 0.072 0.072 0.072 0.072 0.072 0.072 2.384 2.384 2.433 2.433 2.433 2.433 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 DUT Coordinates X (in) Y (in) Z (cm) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Degree DUT Tilt Angle 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Width 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Height Aperture (inch) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Step 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 18.7 18.7 18.7 18.7 18.7 18.7 18.7 18.7 18.7 18.7 18.7 18.7 18.7 18.7 18.7 18.7 18.7 18.7 18.7 18.7 18.7 18.7 18.7 18.7 18.7 18.7 18.7 18.7 18.7 18.7 18.7 18.7 18.7 18.7 18.7 18.7 18.7 Degree Al Degrader Degrader No. Angle Detector Bias (V) 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 621_581_641_714_530 671_471_451_424_590 671_471_451_424_590 671_471_451_424_590 671_471_451_424_590 671_471_451_424_590 671_471_451_424_590 671_471_451_424_590 671_471_451_424_590 671_471_451_424_590 671_471_451_424_590 671_471_451_424_590 671_471_451_424_590 671_471_451_424_590 671_471_451_424_590 671_471_451_424_590 671_471_451_424_590 671_471_451_424_590 671_471_451_424_590 671_471_451_424_590 671_471_451_424_590 671_471_451_424_590 671_471_451_424_590 671_471_451_424_590 671_471_451_424_590 671_471_451_424_590 671_471_451_424_590 671_471_451_424_590 671_471_451_424_590 671_471_451_424_590 671_471_451_424_590 671_471_451_424_590 671_471_451_424_590 671_471_451_424_590 671_471_451_424_590 671_471_451_424_590 671_471_451_424_590 Run FileName IR_March_2006.#2x IR_March_2006.#2y IR_March_2006.#2z IR_March_2006.#30 IR_March_2006.#31 IR_March_2006.#32 IR_March_2006.#33 IR_March_2006.#34 IR_March_2006.#35 IR_March_2006.#36 IR_March_2006.#37 IR_March_2006.#38 IR_March_2006.#39 IR_March_2006.#3a IR_March_2006.#3b IR_March_2006.#3c IR_March_2006.#3d IR_March_2006.#3e IR_March_2006.#3f IR_March_2006.#3g IR_March_2006.#3h IR_March_2006.#3i IR_March_2006.#3j IR_March_2006.#3k IR_March_2006.#3l IR_March_2006.#3m IR_March_2006.#3n IR_March_2006.#3o IR_March_2006.#3p IR_March_2006.#3q IR_March_2006.#3r IR_March_2006.#3s IR_March_2006.#3t IR_March_2006.#3u IR_March_2006.#3v IR_March_2006.#3w IR_March_2006.#3x IR_March_2006.#3y IR_March_2006.#3z IR_March_2006.#40 IR_March_2006.#41 IR_March_2006.#42 IR_March_2006.#43 IR_March_2006.#44 IR_March_2006.#45 IR_March_2006.#46 IR_March_2006.#47 IR_March_2006.#48 IR_March_2006.#49 IR_March_2006.#4a IR_March_2006.#4b IR_March_2006.#4c IR_March_2006.#4d IR_March_2006.#4e IR_March_2006.#4f IR_March_2006.#4g IR_March_2006.#4h IR_March_2006.#4i IR_March_2006.#4j IR_March_2006.#4k IR_March_2006.#4l IR_March_2006.#4m IR_March_2006.#4n IR_March_2006.#4o IR_March_2006.#4p IR_March_2006.#4q IR_March_2006.#4r IR_March_2006.#4s IR_March_2006.#4t IR_March_2006.#4u IR_March_2006.#4v IR_March_2006.#4w IR_March_2006.#4x IR_March_2006.#4y IR_March_2006.#4z IR_March_2006.#50 IR_March_2006.#51 IR_March_2006.#52 IR_March_2006.#53 IR_March_2006.#54 IR_March_2006.#55 IR_March_2006.#56 IR_March_2006.#57 IR_March_2006.#58 IR_March_2006.#59 IR_March_2006.#5a IR_March_2006.#5b IR_March_2006.#5c IR_March_2006.#5d IR_March_2006.#5e IR_March_2006.#5f IR_March_2006.#5g IR_March_2006.#5h IR_March_2006.#5i IR_March_2006.#5j IR_March_2006.#5k IR_March_2006.#5l IR_March_2006.#5m IR_March_2006.#5n IR_March_2006.#5o IR_March_2006.#5p IR_March_2006.#5q IR_March_2006.#5r IR_March_2006.#5s IR_March_2006.#5t Run # 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 Start Date 13:42:38 13:43:36 13:44:24 13:44:57 13:45:32 13:46:10 13:46:50 13:48:28 13:49:22 13:50:08 13:50:54 13:51:34 13:52:44 14:43:03 15:04:34 15:05:21 15:05:57 15:06:30 15:07:09 15:07:46 15:08:17 15:08:49 15:09:25 15:09:57 15:35:00 15:36:00 15:36:40 15:38:53 15:39:58 15:40:32 15:42:33 15:46:23 15:47:02 15:47:34 15:48:05 15:48:36 15:49:10 15:49:41 15:50:12 15:51:57 15:53:20 15:53:56 15:54:30 15:55:02 15:55:33 15:56:03 15:57:51 15:58:27 15:59:26 15:59:56 16:00:28 16:02:02 16:03:26 16:06:31 16:07:53 16:09:47 16:10:23 16:10:56 16:11:30 16:12:59 16:14:13 16:14:53 16:15:29 16:16:02 16:17:39 16:18:53 16:20:33 16:22:23 16:24:23 16:24:59 16:26:08 16:26:44 16:27:13 16:27:50 16:28:20 16:29:25 16:30:27 16:31:27 16:32:23 16:37:36 17:18:58 17:19:32 17:20:03 17:20:38 17:21:16 17:21:50 17:22:21 17:23:39 17:24:14 17:24:48 17:28:29 17:31:12 17:31:42 17:33:03 17:33:35 17:34:04 17:34:37 17:35:08 17:36:31 17:37:31 17:39:20 17:47:23 17:47:58 17:48:43 17:49:16 Start Time 00:00:22_(+_0_days) 00:00:20_(+_0_days) 00:00:19_(+_0_days) 00:00:20_(+_0_days) 00:00:20_(+_0_days) 00:00:21_(+_0_days) 00:00:09_(+_0_days) 00:00:21_(+_0_days) 00:00:21_(+_0_days) 00:00:20_(+_0_days) 00:00:32_(+_0_days) 00:00:47_(+_0_days) 00:00:11_(+_0_days) 00:00:28_(+_0_days) 00:00:22_(+_0_days) 00:00:20_(+_0_days) 00:00:19_(+_0_days) 00:00:20_(+_0_days) 00:00:20_(+_0_days) 00:00:21_(+_0_days) 00:00:21_(+_0_days) 00:00:22_(+_0_days) 00:00:22_(+_0_days) 00:00:23_(+_0_days) 00:00:23_(+_0_days) 00:00:22_(+_0_days) 00:00:22_(+_0_days) 00:00:21_(+_0_days) 00:00:20_(+_0_days) 00:00:20_(+_0_days) 00:00:19_(+_0_days) 00:00:20_(+_0_days) 00:00:19_(+_0_days) 00:00:19_(+_0_days) 00:00:19_(+_0_days) 00:00:21_(+_0_days) 00:00:18_(+_0_days) 00:00:19_(+_0_days) 00:00:10_(+_0_days) 00:00:21_(+_0_days) 00:00:21_(+_0_days) 00:00:19_(+_0_days) 00:00:19_(+_0_days) 00:00:21_(+_0_days) 00:00:19_(+_0_days) 00:00:23_(+_0_days) 00:00:24_(+_0_days) 00:00:46_(+_0_days) 00:00:19_(+_0_days) 00:00:19_(+_0_days) 00:00:09_(+_0_days) 00:00:20_(+_0_days) 00:00:21_(+_0_days) 00:00:24_(+_0_days) 00:00:21_(+_0_days) 00:00:22_(+_0_days) 00:00:22_(+_0_days) 00:00:21_(+_0_days) 00:00:22_(+_0_days) 00:00:23_(+_0_days) 00:00:20_(+_0_days) 00:00:20_(+_0_days) 00:00:19_(+_0_days) 00:00:09_(+_0_days) 00:00:22_(+_0_days) 00:00:21_(+_0_days) 00:00:20_(+_0_days) 00:00:22_(+_0_days) 00:00:20_(+_0_days) 00:00:20_(+_0_days) 00:00:18_(+_0_days) 00:00:19_(+_0_days) 00:00:20_(+_0_days) 00:00:19_(+_0_days) 00:00:13_(+_0_days) 00:00:20_(+_0_days) 00:00:22_(+_0_days) 00:00:20_(+_0_days) 00:00:20_(+_0_days) 00:00:11_(+_0_days) 00:00:20_(+_0_days) 00:00:20_(+_0_days) 00:00:21_(+_0_days) 00:00:27_(+_0_days) 00:00:18_(+_0_days) 00:00:19_(+_0_days) 00:00:19_(+_0_days) 00:00:21_(+_0_days) 00:00:20_(+_0_days) 00:00:20_(+_0_days) 00:00:09_(+_0_days) 00:00:19_(+_0_days) 00:00:20_(+_0_days) 00:00:19_(+_0_days) 00:00:18_(+_0_days) 00:00:20_(+_0_days) 00:00:18_(+_0_days) 00:00:09_(+_0_days) 00:00:19_(+_0_days) 00:00:19_(+_0_days) 00:00:19_(+_0_days) 00:00:19_(+_0_days) 00:00:20_(+_0_days) 00:00:20_(+_0_days) 00:00:20_(+_0_days) Run Duration 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Upset Events 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr Selected Beam 2.111 2.111 2.111 2.111 2.111 2.111 2.111 2.111 2.111 2.111 2.111 2.111 2.111 3.061 3.061 3.061 3.061 3.061 3.061 3.061 3.061 3.061 3.061 3.061 3.061 3.061 3.061 3.061 3.061 3.061 3.061 3.061 3.061 3.061 3.061 3.061 3.061 3.061 3.061 3.061 3.061 3.061 3.061 3.061 3.061 3.061 3.061 3.061 3.061 3.061 3.061 3.061 3.061 3.061 3.061 3.061 3.061 3.061 3.061 3.061 3.061 3.061 3.061 3.061 3.061 3.061 3.061 3.061 3.061 3.061 3.061 3.061 3.061 3.061 3.061 3.061 3.061 3.061 3.061 3.639 3.639 3.639 3.639 3.639 3.639 3.639 3.639 3.639 3.639 3.639 3.639 3.639 3.639 3.639 3.639 3.639 3.639 3.639 3.639 3.639 3.639 3.639 3.639 3.639 3.639 ( µm ) Al Thk 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) # of Layers ( Filename ) 8.1 8.1 8.1 8.1 8.1 8.1 8.1 8.1 8.1 8.1 8.1 8.1 8.1 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 (MeV/amu) 679 679 679 679 679 679 679 679 679 679 679 679 679 463 463 463 463 463 463 463 463 463 463 463 463 463 463 463 463 463 463 463 463 463 463 463 463 463 463 463 463 463 463 463 463 463 463 463 463 463 463 463 463 463 463 463 463 463 463 463 463 463 463 463 463 463 463 463 463 463 463 463 463 463 463 463 463 463 463 317 317 317 317 317 317 317 317 317 317 317 317 317 317 317 317 317 317 317 317 317 317 317 317 317 317 (MeV) Beam Energy silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon 32.4 32.4 32.4 32.4 32.4 32.4 32.4 32.4 32.4 32.4 32.4 32.4 32.4 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 38.9 38.9 38.9 38.9 38.9 38.9 38.9 38.9 38.9 38.9 38.9 38.9 38.9 38.9 38.9 38.9 38.9 38.9 38.9 38.9 38.9 38.9 38.9 38.9 38.9 38.9 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 39.2 39.2 39.2 39.2 39.2 39.2 39.2 39.2 39.2 39.2 39.2 39.2 39.2 39.2 39.2 39.2 39.2 39.2 39.2 39.2 39.2 39.2 39.2 39.2 39.2 39.2 32.4 32.4 32.4 32.4 32.4 32.4 32.4 32.4 32.4 32.4 32.4 32.4 32.4 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 36.1 38.9 38.9 38.9 38.9 38.9 38.9 38.9 38.9 38.9 38.9 38.9 38.9 38.9 38.9 38.9 38.9 38.9 38.9 38.9 38.9 38.9 38.9 38.9 38.9 38.9 38.9 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 39.2 39.2 39.2 39.2 39.2 39.2 39.2 39.2 39.2 39.2 39.2 39.2 39.2 39.2 39.2 39.2 39.2 39.2 39.2 39.2 39.2 39.2 39.2 39.2 39.2 39.2 18 In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current 2.95E+05 3.04E+05 3.09E+05 3.01E+05 3.01E+05 2.92E+05 7.77E+04 3.09E+05 3.02E+05 3.01E+05 3.09E+05 3.05E+05 1.26E+05 3.05E+05 2.97E+05 2.94E+05 2.94E+05 2.93E+05 2.98E+05 2.93E+05 3.00E+05 3.02E+05 2.98E+05 2.99E+05 3.04E+05 3.04E+05 2.92E+05 2.98E+05 3.04E+05 2.91E+05 3.11E+05 3.02E+05 3.04E+05 3.04E+05 2.95E+05 3.00E+05 2.92E+05 2.94E+05 7.39E+04 3.09E+05 3.03E+05 2.99E+05 2.98E+05 3.07E+05 3.01E+05 2.98E+05 3.06E+05 2.97E+05 2.97E+05 2.90E+05 4.92E+04 2.91E+05 3.09E+05 2.93E+05 2.98E+05 2.95E+05 2.96E+05 3.08E+05 2.98E+05 3.00E+05 3.07E+05 2.94E+05 3.01E+05 4.78E+04 2.96E+05 2.91E+05 3.00E+05 3.01E+05 3.01E+05 3.10E+05 2.97E+05 2.90E+05 3.02E+05 3.00E+05 2.36E+04 2.97E+05 3.09E+05 3.07E+05 3.08E+05 1.02E+05 3.03E+05 3.05E+05 3.10E+05 2.90E+05 2.90E+05 3.09E+05 2.93E+05 2.95E+05 3.07E+05 3.06E+05 6.96E+04 2.92E+05 2.99E+05 2.95E+05 3.03E+05 3.10E+05 3.04E+05 7.21E+04 3.10E+05 3.00E+05 3.01E+05 3.10E+05 3.09E+05 3.10E+05 3.09E+05 Nominal Nominal Effective Effective Effective Target LET Range LET Range DUT Position Fluence 2 (MeV.cm /mg) Material (MeV.cm2/mg) Location Name ( ions/cm2 ) ( µm ) ( µm ) 1.53E+02 1.58E+02 1.60E+02 1.56E+02 1.56E+02 1.52E+02 4.03E+01 1.60E+02 1.57E+02 1.56E+02 1.60E+02 1.59E+02 6.54E+01 1.77E+02 1.72E+02 1.70E+02 1.70E+02 1.69E+02 1.73E+02 1.69E+02 1.73E+02 1.75E+02 1.72E+02 1.73E+02 1.76E+02 1.76E+02 1.69E+02 1.72E+02 1.76E+02 1.69E+02 1.80E+02 1.75E+02 1.76E+02 1.76E+02 1.70E+02 1.74E+02 1.69E+02 1.70E+02 4.27E+01 1.79E+02 1.75E+02 1.73E+02 1.72E+02 1.78E+02 1.74E+02 1.72E+02 1.77E+02 1.72E+02 1.72E+02 1.68E+02 2.84E+01 1.68E+02 1.79E+02 1.69E+02 1.72E+02 1.71E+02 1.71E+02 1.78E+02 1.72E+02 1.74E+02 1.78E+02 1.70E+02 1.74E+02 2.76E+01 1.71E+02 1.68E+02 1.73E+02 1.74E+02 1.74E+02 1.79E+02 1.72E+02 1.68E+02 1.75E+02 1.74E+02 1.37E+01 1.72E+02 1.79E+02 1.78E+02 1.78E+02 6.34E+01 1.89E+02 1.90E+02 1.93E+02 1.81E+02 1.81E+02 1.93E+02 1.82E+02 1.84E+02 1.91E+02 1.91E+02 4.34E+01 1.82E+02 1.87E+02 1.84E+02 1.89E+02 1.93E+02 1.90E+02 4.50E+01 1.93E+02 1.87E+02 1.88E+02 1.93E+02 1.93E+02 1.93E+02 1.92E+02 ( rad ) Dose International Rectifier Corp. SEE Test Report March 2006 – T.A.M.U. 14.5833 15.2 15.3833 15.0167 15.3667 14.9167 4.23333 15.9 15.2333 15.7 15.65 15.6333 6.68333 21.1833 14.9167 15.3167 15.35 15.6333 15.7833 15.5333 16.8333 17.5833 17.4333 17.9667 17.65 17.7 17.25 15.5333 16 15.75 14.3667 14.6333 14.65 14.1667 14.3833 15.6667 13.7833 13.6667 3.71667 15.3 15.3667 14.4667 14.7833 15.4 15.3333 15.1667 14.7 14.75 15.2333 15.1 3.01667 15.8167 16.2 14.8167 16.1 16.7 16.75 17.1833 17.0833 17.75 15.2833 14.6 14.7833 2.66667 14.1167 15.2167 15.0833 14.5667 14.8667 14.7667 14.1667 13.9 14.8167 14.3333 1.8 14.9 15.6 15.4833 14.8167 5.65 14.8667 15.5333 15.9167 14.2833 13.8 14.8167 14.3167 14.55 14.9667 15.1833 3.73333 14.2167 14.5667 14.2333 14.25 14.8833 14.4833 3.9 14.85 14.3167 13.7833 14.6167 15.0167 15.0833 14.9167 ( sec.) Live Time 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2.02E+04 2.00E+04 2.01E+04 2.00E+04 1.96E+04 1.96E+04 1.83E+04 1.94E+04 1.98E+04 1.91E+04 1.97E+04 1.95E+04 1.89E+04 1.44E+04 1.99E+04 1.92E+04 1.92E+04 1.87E+04 1.89E+04 1.88E+04 1.78E+04 1.72E+04 1.71E+04 1.66E+04 1.72E+04 1.72E+04 1.69E+04 1.92E+04 1.90E+04 1.85E+04 2.16E+04 2.07E+04 2.07E+04 2.14E+04 2.05E+04 1.92E+04 2.12E+04 2.15E+04 1.99E+04 2.02E+04 1.97E+04 2.07E+04 2.01E+04 1.99E+04 1.96E+04 1.96E+04 2.08E+04 2.02E+04 1.95E+04 1.92E+04 1.63E+04 1.84E+04 1.91E+04 1.97E+04 1.85E+04 1.77E+04 1.77E+04 1.79E+04 1.74E+04 1.69E+04 2.01E+04 2.02E+04 2.03E+04 1.79E+04 2.09E+04 1.91E+04 1.99E+04 2.07E+04 2.03E+04 2.10E+04 2.09E+04 2.08E+04 2.04E+04 2.09E+04 1.31E+04 2.00E+04 1.98E+04 1.98E+04 2.08E+04 1.80E+04 2.04E+04 1.97E+04 1.95E+04 2.03E+04 2.10E+04 2.09E+04 2.04E+04 2.03E+04 2.05E+04 2.02E+04 1.86E+04 2.05E+04 2.06E+04 2.07E+04 2.13E+04 2.09E+04 2.10E+04 1.85E+04 2.09E+04 2.09E+04 2.19E+04 2.12E+04 2.06E+04 2.06E+04 2.07E+04 Average Flux 0.58 0.57 0.57 0.58 0.58 0.58 1.1 0.57 0.58 0.58 0.57 0.57 0.89 0.57 0.58 0.58 0.58 0.58 0.58 0.58 0.58 0.58 0.58 0.58 0.57 0.57 0.59 0.58 0.57 0.59 0.57 0.58 0.57 0.57 0.58 0.58 0.58 0.58 1.2 0.57 0.57 0.58 0.58 0.57 0.58 0.58 0.57 0.58 0.58 0.59 1.4 0.59 0.57 0.58 0.58 0.58 0.58 0.57 0.58 0.58 0.57 0.58 0.58 1.4 0.58 0.59 0.58 0.58 0.58 0.57 0.58 0.59 0.58 0.58 2.1 0.58 0.57 0.57 0.57 0.99 0.57 0.57 0.57 0.59 0.59 0.57 0.58 0.58 0.57 0.57 1.2 0.59 0.58 0.58 0.57 0.57 0.57 1.2 0.57 0.58 0.58 0.57 0.57 0.57 0.57 80 80 80 81 80 80 80 80 81 80 81 80 80 81 81 80 80 81 81 82 81 81 81 81 93 92 93 87 87 88 87 87 88 87 87 88 88 87 88 88 88 87 88 87 88 88 88 87 87 88 88 87 87 87 86 86 86 87 87 86 87 87 87 88 87 87 86 88 87 88 88 87 88 87 88 87 85 87 88 88 87 88 88 88 90 89 89 88 88 89 90 89 89 86 86 87 87 89 89 90 90 91 90 90 90 13 13 13 13 14 14 13 14 13 13 13 13 14 13 14 13 14 13 13 12 13 13 13 13 5 5 4 8 8 7 8 8 8 8 8 7 8 8 8 8 8 8 7 8 8 7 7 8 8 8 8 8 8 8 9 8 9 8 8 8 9 8 9 9 8 9 9 8 9 8 8 8 8 8 9 9 10 9 8 8 9 8 8 8 7 7 8 8 8 7 7 8 7 9 10 9 9 8 7 7 7 6 7 7 7 1.25491 1.25447 1.25378 1.24458 1.23827 1.24915 1.26797 1.25022 1.26773 1.24081 1.27618 1.26572 1.29021 1.25321 1.21664 1.08859 1.10133 1.11913 1.13837 1.13476 1.12533 1.11549 1.13936 1.08023 1.23524 1.23321 1.22921 1.19684 1.21296 1.18411 1.209 1.21807 1.21183 1.2334 1.22052 1.22274 1.22177 1.24612 1.21501 1.19151 1.21511 1.22918 1.22285 1.23016 1.21198 1.21283 1.23436 1.21464 1.21147 1.22047 1.23157 1.21382 1.22719 1.22764 1.22418 1.2102 1.22611 1.23461 1.21423 1.20679 1.20822 1.21418 1.20204 1.23665 1.23944 1.20303 1.21875 1.20111 1.20012 1.23295 1.22529 1.25261 1.19074 1.22135 1.21002 1.21525 1.21525 1.20889 1.22528 1.3125 1.32895 1.32718 1.29525 1.33568 1.33042 1.31607 1.3264 1.32769 1.33297 1.33563 1.33883 1.3082 1.30372 1.30671 1.3476 1.29508 1.32615 1.31824 1.32181 1.31017 1.3467 1.34334 1.32607 1.34565 1.31216 Overall AvgFlux Overall Central Error Uniformity Shift Calibration 2 (%) (%) (%) Factor ( sec.) ( ions/(cm s) ) Dead Time 2.494 2.494 2.494 2.494 2.494 2.494 2.494 4.094 4.094 4.094 4.094 4.094 4.094 -3.844 -2.244 -2.244 -2.244 -2.244 -2.244 -2.244 -2.244 -2.244 -2.244 -2.244 -2.244 -2.244 -2.244 -2.244 -2.244 -2.244 -2.244 -0.657 -0.657 -0.657 -0.657 -0.657 -0.657 -0.657 -0.657 0.955 0.955 0.955 0.955 0.955 0.955 0.955 0.955 0.955 0.955 0.955 0.955 2.543 4.142 -3.87 -2.27 -0.683 -0.683 -0.683 -0.683 -0.683 -0.683 -0.683 -0.683 -0.683 0.931 2.531 4.119 -3.894 -2.307 -2.307 -2.307 -2.307 -2.307 -2.307 -2.307 -0.707 0.881 2.494 4.094 4.094 -3.844 -3.844 -3.844 -3.844 -3.844 -3.844 -3.844 -3.844 -3.844 -3.844 -2.244 0.955 0.955 0.955 0.955 0.955 0.955 0.955 2.543 4.142 -3.87 -0.683 -0.683 -0.683 -0.683 2.483 2.483 2.483 2.483 2.483 2.483 2.483 2.508 2.508 2.508 2.508 2.508 2.508 -2.443 -2.418 -2.418 -2.418 -2.418 -2.418 -2.418 -2.418 -2.418 -2.418 -2.418 -2.418 -2.418 -2.418 -2.418 -2.418 -2.418 -2.418 -2.393 -2.393 -2.393 -2.393 -2.393 -2.393 -2.393 -2.393 -2.393 -2.393 -2.393 -2.393 -2.393 -2.393 -2.393 -2.393 -2.393 -2.393 -2.393 -2.393 -2.343 -2.343 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 0.046 0.072 2.384 2.384 2.384 2.384 2.384 2.384 2.384 2.384 2.433 2.433 2.483 2.508 2.508 -2.443 -2.443 -2.443 -2.443 -2.443 -2.443 -2.443 -2.443 -2.443 -2.443 -2.418 -2.393 -2.393 -2.393 -2.393 -2.393 -2.393 -2.393 -2.343 -2.343 -0.003 -0.003 -0.003 -0.003 -0.003 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 DUT Coordinates X (in) Y (in) Z (cm) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Degree DUT Tilt Angle 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Width 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Height Aperture (inch) 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Step 18.7 18.7 18.7 18.7 18.7 18.7 18.7 18.7 18.7 18.7 18.7 18.7 18.7 49.2 49.2 49.2 49.2 49.2 49.2 49.2 49.2 49.2 49.2 49.2 49.2 49.2 49.2 49.2 49.2 49.2 49.2 49.2 49.2 49.2 49.2 49.2 49.2 49.2 49.2 49.2 49.2 49.2 49.2 49.2 49.2 49.2 49.2 49.2 49.2 49.2 49.2 49.2 49.2 49.2 49.2 49.2 49.2 49.2 49.2 49.2 49.2 49.2 49.2 49.2 49.2 49.2 49.2 49.2 49.2 49.2 49.2 49.2 49.2 49.2 49.2 49.2 49.2 49.2 49.2 56.663 56.663 56.663 56.663 56.663 56.663 56.663 56.663 56.663 56.663 56.663 56.663 56.663 56.663 56.663 56.663 56.663 56.663 56.663 56.663 56.663 56.663 56.663 56.663 56.663 56.663 Degree Al Degrader Degrader No. Angle Detector Bias (V) 671_471_451_424_590 671_471_451_424_590 671_471_451_424_590 671_471_451_424_590 671_471_451_424_590 671_471_451_424_590 671_471_451_424_590 671_471_451_424_590 671_471_451_424_590 671_471_451_424_590 671_471_451_424_590 671_471_451_424_590 671_471_451_424_590 694_506_476_444_648 704_506_476_444_648 704_506_476_444_648 704_506_476_444_648 704_506_476_444_648 704_506_476_444_648 704_506_476_444_648 704_506_476_444_648 704_506_476_444_648 704_506_476_444_648 704_506_476_444_648 704_506_476_444_648 704_506_476_444_648 704_506_476_444_648 704_506_476_444_648 704_506_476_444_648 704_506_476_444_648 704_506_476_444_648 704_476_496_474_648 704_476_496_474_648 704_476_496_474_648 704_476_496_474_648 704_476_496_474_648 704_476_496_474_648 704_476_496_474_648 704_476_496_474_648 704_476_496_474_648 704_476_496_474_648 704_476_496_474_648 704_476_496_474_648 704_476_496_474_648 704_476_496_474_648 704_476_496_474_648 704_476_496_474_648 704_476_496_474_648 704_476_496_474_648 704_476_496_474_648 704_476_496_474_648 704_476_496_474_648 704_476_496_474_648 704_476_496_474_648 704_476_496_474_648 704_476_496_474_648 704_476_496_474_648 704_476_496_474_648 704_476_496_474_648 704_476_496_474_648 704_476_496_474_648 704_476_496_474_648 704_476_496_474_648 704_476_496_474_648 704_476_496_474_648 704_476_496_474_648 704_476_496_474_648 704_476_496_474_648 704_476_496_474_648 704_476_496_474_648 704_476_496_474_648 704_476_496_474_648 704_476_496_474_648 704_476_496_474_648 704_476_496_474_648 704_476_496_474_648 704_476_496_474_648 704_476_496_474_648 704_476_496_474_648 727_495_526_504_700 727_495_526_504_700 727_495_526_504_700 727_495_526_504_700 727_495_526_504_700 727_495_526_504_700 727_495_526_504_700 727_495_526_504_700 727_495_526_504_700 727_495_526_504_700 727_495_526_504_700 727_495_526_504_700 727_495_526_504_700 727_495_526_504_700 727_495_526_504_700 727_495_526_504_700 727_495_526_504_700 727_495_526_504_700 727_495_526_504_700 727_495_526_504_700 727_495_526_504_700 727_495_526_504_700 727_495_526_504_700 727_495_526_504_700 727_495_526_504_700 727_495_526_504_700 Run FileName IR_March_2006.#5u IR_March_2006.#5v IR_March_2006.#5w IR_March_2006.#5x IR_March_2006.#5y IR_March_2006.#5z IR_March_2006.#60 IR_March_2006.#61 IR_March_2006.#62 IR_March_2006.#63 IR_March_2006.#64 IR_March_2006.#65 IR_March_2006.#66 IR_March_2006.#67 IR_March_2006.#68 IR_March_2006.#69 IR_March_2006.#6a IR_March_2006.#6b IR_March_2006.#6c IR_March_2006.#6d IR_March_2006.#6e IR_March_2006.#6f IR_March_2006.#6g IR_March_2006.#6h IR_March_2006.#6i IR_March_2006.#6j IR_March_2006.#6k IR_March_2006.#6l IR_March_2006.#6m IR_March_2006.#6n IR_March_2006.#6o IR_March_2006.#6p IR_March_2006.#6q IR_March_2006.#6r IR_March_2006.#6s IR_March_2006.#6t IR_March_2006.#6u IR_March_2006.#6v IR_March_2006.#6w IR_March_2006.#6x IR_March_2006.#6y IR_March_2006.#6z IR_March_2006.#70 IR_March_2006.#71 IR_March_2006.#72 IR_March_2006.#73 IR_March_2006.#74 IR_March_2006.#75 IR_March_2006.#76 IR_March_2006.#77 IR_March_2006.#78 IR_March_2006.#79 IR_March_2006.#7a IR_March_2006.#7b IR_March_2006.#7c IR_March_2006.#7d IR_March_2006.#7e IR_March_2006.#7f IR_March_2006.#7g IR_March_2006.#7h IR_March_2006.#7i IR_March_2006.#7j IR_March_2006.#7k IR_March_2006.#7l IR_March_2006.#7m IR_March_2006.#7n IR_March_2006.#7o IR_March_2006.#7p IR_March_2006.#7q IR_March_2006.#7r IR_March_2006.#7s IR_March_2006.#7t IR_March_2006.#7u IR_March_2006.#7v IR_March_2006.#7w IR_March_2006.#7x IR_March_2006.#7y IR_March_2006.#7z IR_March_2006.#80 IR_March_2006.#81 IR_March_2006.#82 IR_March_2006.#83 IR_March_2006.#84 IR_March_2006.#85 IR_March_2006.#86 IR_March_2006.#87 IR_March_2006.#88 IR_March_2006.#89 IR_March_2006.#8a IR_March_2006.#8b IR_March_2006.#8c IR_March_2006.#8d IR_March_2006.#8e IR_March_2006.#8f IR_March_2006.#8g IR_March_2006.#8h IR_March_2006.#8i IR_March_2006.#8j IR_March_2006.#8k IR_March_2006.#8l IR_March_2006.#8m IR_March_2006.#8n IR_March_2006.#8o IR_March_2006.#8p IR_March_2006.#8q Run # 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 Start Date 17:49:57 17:50:29 17:50:59 17:52:33 17:53:48 17:54:54 17:56:47 17:58:44 17:59:14 17:59:59 18:00:36 18:01:16 18:01:47 18:02:52 18:04:07 18:05:20 18:56:48 18:57:46 18:58:25 18:59:00 18:59:33 19:00:40 19:01:17 19:01:50 19:02:27 19:03:01 19:03:37 19:04:10 19:04:43 19:05:25 19:05:59 19:06:33 19:07:06 19:11:10 19:11:58 19:13:05 19:13:46 19:16:11 19:16:59 19:22:01 19:22:59 19:23:50 19:24:54 19:25:29 19:30:18 19:31:01 19:32:04 19:33:01 19:33:36 19:34:17 19:34:50 19:35:24 19:35:59 19:37:58 19:42:07 19:43:48 19:44:28 19:45:07 19:45:45 19:48:01 19:48:31 19:49:02 19:50:13 19:51:43 19:52:16 19:53:02 19:53:38 19:55:15 19:55:49 19:56:24 19:56:58 19:57:48 19:58:22 19:59:58 20:01:00 20:02:43 20:35:58 20:36:35 20:37:20 20:37:58 20:38:26 20:38:55 20:39:25 20:42:07 20:42:46 20:43:22 20:43:59 20:44:33 20:47:01 20:47:36 20:48:10 20:48:42 20:51:06 20:51:40 20:52:11 20:52:42 20:53:13 20:56:06 20:56:47 20:57:44 20:58:14 21:02:13 21:03:02 21:03:41 21:04:16 Start Time 00:00:18_(+_0_days) 00:00:19_(+_0_days) 00:00:16_(+_0_days) 00:00:19_(+_0_days) 00:00:11_(+_0_days) 00:00:24_(+_0_days) 00:00:23_(+_0_days) 00:00:20_(+_0_days) 00:00:20_(+_0_days) 00:00:21_(+_0_days) 00:00:25_(+_0_days) 00:00:19_(+_0_days) 00:00:14_(+_0_days) 00:00:24_(+_0_days) 00:00:19_(+_0_days) 00:00:21_(+_0_days) 00:00:21_(+_0_days) 00:00:22_(+_0_days) 00:00:21_(+_0_days) 00:00:20_(+_0_days) 00:00:20_(+_0_days) 00:00:20_(+_0_days) 00:00:19_(+_0_days) 00:00:19_(+_0_days) 00:00:20_(+_0_days) 00:00:19_(+_0_days) 00:00:19_(+_0_days) 00:00:19_(+_0_days) 00:00:19_(+_0_days) 00:00:18_(+_0_days) 00:00:18_(+_0_days) 00:00:19_(+_0_days) 00:00:19_(+_0_days) 00:00:21_(+_0_days) 00:00:24_(+_0_days) 00:00:20_(+_0_days) 00:00:19_(+_0_days) 00:00:19_(+_0_days) 00:00:20_(+_0_days) 00:00:24_(+_0_days) 00:00:20_(+_0_days) 00:00:27_(+_0_days) 00:00:21_(+_0_days) 00:00:11_(+_0_days) 00:00:24_(+_0_days) 00:00:22_(+_0_days) 00:00:25_(+_0_days) 00:00:21_(+_0_days) 00:00:19_(+_0_days) 00:00:19_(+_0_days) 00:00:20_(+_0_days) 00:00:21_(+_0_days) 00:00:15_(+_0_days) 00:00:20_(+_0_days) 00:00:14_(+_0_days) 00:00:19_(+_0_days) 00:00:20_(+_0_days) 00:00:19_(+_0_days) 00:00:16_(+_0_days) 00:00:18_(+_0_days) 00:00:19_(+_0_days) 00:00:18_(+_0_days) 00:00:18_(+_0_days) 00:00:24_(+_0_days) 00:00:21_(+_0_days) 00:00:20_(+_0_days) 00:00:18_(+_0_days) 00:00:19_(+_0_days) 00:00:19_(+_0_days) 00:00:18_(+_0_days) 00:00:18_(+_0_days) 00:00:19_(+_0_days) 00:00:21_(+_0_days) 00:00:19_(+_0_days) 00:00:19_(+_0_days) 00:00:27_(+_0_days) 00:00:17_(+_0_days) 00:00:18_(+_0_days) 00:00:18_(+_0_days) 00:00:18_(+_0_days) 00:00:18_(+_0_days) 00:00:17_(+_0_days) 00:00:17_(+_0_days) 00:00:19_(+_0_days) 00:00:19_(+_0_days) 00:00:19_(+_0_days) 00:00:18_(+_0_days) 00:00:07_(+_0_days) 00:00:20_(+_0_days) 00:00:19_(+_0_days) 00:00:18_(+_0_days) 00:00:13_(+_0_days) 00:00:18_(+_0_days) 00:00:20_(+_0_days) 00:00:20_(+_0_days) 00:00:18_(+_0_days) 00:00:08_(+_0_days) 00:00:22_(+_0_days) 00:00:22_(+_0_days) 00:00:20_(+_0_days) 00:00:09_(+_0_days) 00:00:20_(+_0_days) 00:00:20_(+_0_days) 00:00:21_(+_0_days) 00:00:22_(+_0_days) Run Duration 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Upset Events 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr Selected Beam 3.639 3.639 3.639 3.639 3.639 3.639 3.639 3.639 3.639 3.639 3.639 3.639 3.639 3.639 3.639 3.639 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3.254 3.254 3.254 3.254 3.254 3.254 3.254 3.254 3.254 3.254 3.254 3.254 3.254 3.254 3.254 3.254 3.254 3.254 3.254 3.254 3.254 3.254 3.254 3.254 3.254 3.254 3.254 3.254 3.254 3.254 3.254 3.254 3.254 3.254 3.254 3.254 3.254 1 1 1 1 1 1 1 2.111 2.111 2.111 2.111 2.111 3.038 3.038 3.038 3.038 3.542 3.542 3.542 3.542 3.542 3.944 3.944 3.944 3.944 3.944 3.944 3.944 3.944 ( µm ) Al Thk 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) # of Layers ( Filename ) 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 10.8 10.8 10.8 10.8 10.8 10.8 10.8 8.1 8.1 8.1 8.1 8.1 5.6 5.6 5.6 5.6 4.1 4.1 4.1 4.1 4.1 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 (MeV/amu) 317 317 317 317 317 317 317 317 317 317 317 317 317 317 317 317 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 1092 416 416 416 416 416 416 416 416 416 416 416 416 416 416 416 416 416 416 416 416 416 416 416 416 416 416 416 416 416 416 416 416 416 416 416 416 416 905 905 905 905 905 905 905 679 679 679 679 679 469 469 469 469 342 342 342 342 342 234 234 234 234 234 234 234 234 (MeV) Beam Energy silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon 38.9 38.9 38.9 38.9 38.9 38.9 38.9 38.9 38.9 38.9 38.9 38.9 38.9 38.9 38.9 38.9 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 29.4 29.4 29.4 29.4 29.4 29.4 29.4 32.4 32.4 32.4 32.4 32.4 36 36 36 36 38.4 38.4 38.4 38.4 38.4 40.5 40.5 40.5 40.5 40.5 40.5 40.5 40.5 39.2 39.2 39.2 39.2 39.2 39.2 39.2 39.2 39.2 39.2 39.2 39.2 39.2 39.2 39.2 39.2 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 115 115 115 115 115 115 115 83.3 83.3 83.3 83.3 83.3 56.7 56.7 56.7 56.7 42.1 42.1 42.1 42.1 42.1 30.3 30.3 30.3 30.3 30.3 30.3 30.3 30.3 38.9 38.9 38.9 38.9 38.9 38.9 38.9 38.9 38.9 38.9 38.9 38.9 38.9 38.9 38.9 38.9 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 27.2 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 29.4 29.4 29.4 29.4 29.4 29.4 29.4 32.4 32.4 32.4 32.4 32.4 36 36 36 36 38.4 38.4 38.4 38.4 38.4 40.5 40.5 40.5 40.5 40.5 40.5 40.5 40.5 39.2 39.2 39.2 39.2 39.2 39.2 39.2 39.2 39.2 39.2 39.2 39.2 39.2 39.2 39.2 39.2 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 143.4 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 115 115 115 115 115 115 115 83.3 83.3 83.3 83.3 83.3 56.7 56.7 56.7 56.7 42.1 42.1 42.1 42.1 42.1 30.3 30.3 30.3 30.3 30.3 30.3 30.3 30.3 19 In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current pos_01 pos_01 pos_01 pos_01 pos_01 pos_01 pos_01 pos_01 pos_01 pos_01 pos_01 pos_01 pos_01 pos_01 pos_01 pos_01 pos_01 Current Current pos_03 pos_03 pos_04 pos_04 Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current 2.99E+05 3.02E+05 2.29E+05 3.00E+05 1.07E+05 3.03E+05 3.07E+05 2.94E+05 3.00E+05 3.09E+05 3.09E+05 3.07E+05 1.87E+05 3.02E+05 2.99E+05 3.07E+05 2.94E+05 3.04E+05 3.01E+05 3.06E+05 3.05E+05 2.98E+05 3.03E+05 3.06E+05 3.06E+05 3.05E+05 3.10E+05 3.04E+05 3.02E+05 2.92E+05 2.92E+05 3.00E+05 3.10E+05 2.92E+05 3.05E+05 2.99E+05 3.08E+05 2.97E+05 3.04E+05 2.97E+05 2.96E+05 2.91E+05 2.92E+05 9.03E+04 2.92E+05 3.03E+05 2.98E+05 2.95E+05 2.92E+05 2.96E+05 2.99E+05 3.05E+05 1.80E+05 2.92E+05 1.74E+05 2.99E+05 2.99E+05 2.92E+05 1.58E+05 3.04E+05 3.08E+05 2.99E+05 2.92E+05 3.03E+05 3.02E+05 3.02E+05 2.90E+05 3.03E+05 3.04E+05 2.96E+05 2.95E+05 3.08E+05 3.02E+05 2.94E+05 3.07E+05 2.97E+05 2.90E+05 3.09E+05 3.05E+05 3.03E+05 2.95E+05 3.03E+05 2.32E+05 2.97E+05 3.08E+05 3.03E+05 3.08E+05 5.97E+04 2.97E+05 3.08E+05 2.96E+05 1.76E+05 3.02E+05 3.07E+05 2.91E+05 2.94E+05 3.84E+04 2.96E+05 3.08E+05 2.94E+05 6.12E+04 2.90E+05 2.99E+05 3.04E+05 2.90E+05 Nominal Nominal Effective Effective Effective Target LET Range LET Range DUT Position Fluence 2 (MeV.cm /mg) Material (MeV.cm2/mg) Location Name ( ions/cm2 ) ( µm ) ( µm ) 1.86E+02 1.88E+02 1.43E+02 1.87E+02 6.68E+01 1.89E+02 1.91E+02 1.83E+02 1.87E+02 1.93E+02 1.93E+02 1.91E+02 1.17E+02 1.88E+02 1.86E+02 1.91E+02 1.28E+02 1.32E+02 1.31E+02 1.33E+02 1.33E+02 1.30E+02 1.32E+02 1.33E+02 1.33E+02 1.33E+02 1.35E+02 1.32E+02 1.31E+02 1.27E+02 1.27E+02 1.30E+02 1.35E+02 1.27E+02 1.33E+02 1.30E+02 1.34E+02 1.29E+02 1.32E+02 1.76E+02 1.76E+02 1.73E+02 1.73E+02 5.35E+01 1.73E+02 1.80E+02 1.77E+02 1.75E+02 1.73E+02 1.75E+02 1.77E+02 1.81E+02 1.07E+02 1.73E+02 1.03E+02 1.77E+02 1.77E+02 1.73E+02 9.34E+01 1.80E+02 1.83E+02 1.77E+02 1.73E+02 1.80E+02 1.79E+02 1.79E+02 1.72E+02 1.80E+02 1.80E+02 1.76E+02 1.75E+02 1.82E+02 1.79E+02 1.74E+02 1.82E+02 1.76E+02 1.37E+02 1.45E+02 1.44E+02 1.43E+02 1.39E+02 1.43E+02 1.09E+02 1.54E+02 1.60E+02 1.57E+02 1.60E+02 3.10E+01 1.72E+02 1.78E+02 1.71E+02 1.02E+02 1.86E+02 1.89E+02 1.79E+02 1.81E+02 2.36E+01 1.92E+02 2.00E+02 1.91E+02 3.97E+01 1.88E+02 1.94E+02 1.97E+02 1.88E+02 ( rad ) Dose International Rectifier Corp. SEE Test Report March 2006 – T.A.M.U. 14.3833 14.3833 10.95 14.15 5.31667 14.25 14.4333 14.4333 14.6667 15.2833 15.4167 15.3167 9.48333 15.3667 14.6167 14.8833 15.6667 16.3 15.6667 15.9333 15.55 14.9667 14.7167 15.1167 15.4 14.7167 15.3 15.4333 14.5333 13.8833 14.1833 14.9 14.6167 15.0167 15.9 14.6167 15.2 14.1667 14.3833 16.2 16.35 16.5667 16.5333 5.53333 16.4667 16.9833 16.1667 15.85 15.15 15.2833 15.7 16.4833 9.86667 15.7833 7.91667 14.4667 13.95 13.8 7.75 13.9833 14.7833 14.1333 13.9833 15.7167 15.65 15.1167 14.1833 14.55 14.0833 14.0167 14.0667 15.05 14.5167 14.3 14.75 15.0833 12.8333 13.5167 13.7333 13.8 13.5 13.6333 10.5833 13.4667 14.4167 14.35 14.1333 3.18333 13.8333 14.5 13.4833 8.03333 14.5667 14.7167 13.9667 14 2.26667 14.65 15.6667 15.0333 3.51667 14.85 15.1333 15.2833 14.35 ( sec.) Live Time 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2.08E+04 2.10E+04 2.09E+04 2.12E+04 2.02E+04 2.13E+04 2.13E+04 2.03E+04 2.05E+04 2.02E+04 2.01E+04 2.00E+04 1.97E+04 1.97E+04 2.04E+04 2.06E+04 1.87E+04 1.87E+04 1.92E+04 1.92E+04 1.96E+04 1.99E+04 2.06E+04 2.02E+04 1.98E+04 2.07E+04 2.03E+04 1.97E+04 2.08E+04 2.10E+04 2.06E+04 2.01E+04 2.12E+04 1.94E+04 1.92E+04 2.04E+04 2.03E+04 2.10E+04 2.12E+04 1.84E+04 1.81E+04 1.76E+04 1.77E+04 1.63E+04 1.77E+04 1.79E+04 1.85E+04 1.86E+04 1.93E+04 1.93E+04 1.90E+04 1.85E+04 1.82E+04 1.85E+04 2.20E+04 2.07E+04 2.14E+04 2.12E+04 2.03E+04 2.18E+04 2.09E+04 2.11E+04 2.09E+04 1.93E+04 1.93E+04 2.00E+04 2.04E+04 2.08E+04 2.16E+04 2.11E+04 2.10E+04 2.05E+04 2.08E+04 2.06E+04 2.08E+04 1.97E+04 2.26E+04 2.28E+04 2.22E+04 2.20E+04 2.18E+04 2.23E+04 2.19E+04 2.21E+04 2.13E+04 2.11E+04 2.18E+04 1.88E+04 2.15E+04 2.13E+04 2.20E+04 2.19E+04 2.07E+04 2.09E+04 2.09E+04 2.10E+04 1.69E+04 2.02E+04 1.96E+04 1.95E+04 1.74E+04 1.95E+04 1.98E+04 1.99E+04 2.02E+04 Average Flux 0.58 0.58 0.66 0.58 0.97 0.57 0.57 0.58 0.58 0.57 0.57 0.57 0.73 0.58 0.58 0.57 0.58 0.57 0.58 0.57 0.57 0.58 0.57 0.57 0.57 0.57 0.57 0.57 0.58 0.59 0.59 0.58 0.57 0.59 0.57 0.58 0.57 0.58 0.57 0.58 0.58 0.59 0.59 1.1 0.59 0.57 0.58 0.58 0.59 0.58 0.58 0.57 0.75 0.59 0.76 0.58 0.58 0.58 0.8 0.57 0.57 0.58 0.59 0.57 0.58 0.58 0.59 0.57 0.57 0.58 0.58 0.57 0.58 0.58 0.57 0.58 0.59 0.57 0.57 0.57 0.58 0.57 0.66 0.58 0.57 0.57 0.57 1.3 0.58 0.57 0.58 0.75 0.58 0.57 0.59 0.58 1.6 0.58 0.57 0.58 1.3 0.59 0.58 0.57 0.59 90 90 90 90 91 90 90 89 89 89 89 88 90 90 89 89 85 86 85 85 86 85 84 83 83 84 84 83 83 83 84 83 83 84 84 84 84 83 83 78 78 78 79 78 78 78 78 78 78 78 79 79 79 79 90 89 89 90 90 92 91 92 91 90 90 92 91 91 91 90 90 90 90 88 88 87 91 92 92 92 91 92 92 91 91 92 91 93 90 89 89 90 88 89 89 89 90 90 90 90 89 90 91 89 90 7 7 7 6 6 6 7 7 8 8 7 8 7 7 8 7 9 9 9 10 9 9 10 11 10 10 10 10 10 11 10 10 11 10 10 10 10 10 10 17 17 18 17 18 17 17 17 18 17 17 16 17 16 16 6 7 7 7 7 5 6 5 6 7 7 5 6 6 6 6 7 7 6 8 8 9 6 5 6 6 6 5 6 6 7 6 6 5 6 7 8 7 8 7 7 7 7 6 7 6 8 6 5 6 6 1.31637 1.34388 1.31854 1.31854 1.34266 1.33278 1.32753 1.33854 1.34135 1.32744 1.34187 1.31172 1.32365 1.30062 1.3364 1.30348 0.989569 0.964933 0.974216 0.999111 1.00385 0.970475 0.957032 0.943231 0.923573 0.950122 0.925408 0.913672 0.956145 0.945956 0.934134 0.925352 0.944694 0.924977 0.907493 0.950168 0.935149 0.931793 0.938724 1.37691 1.38985 1.37143 1.3801 1.38313 1.34953 1.36683 1.3779 1.39253 1.38775 1.38588 1.37614 1.37752 1.38264 1.39219 1.30483 1.24999 1.30625 1.27256 1.30533 1.30533 1.3009 1.30744 1.34281 1.30374 1.31154 1.30367 1.30815 1.28215 1.32281 1.3335 1.31228 1.30457 1.30725 1.3142 1.32552 1.29454 1.03665 1.03765 1.01788 1.0257 1.02877 1.0467 1.04059 1.17914 1.15323 1.14489 1.17027 1.14399 1.28689 1.3016 1.29758 1.31807 1.34853 1.35924 1.34776 1.35609 1.34796 1.38504 1.37286 1.37878 1.37301 1.37075 1.37895 1.37242 1.397 Overall AvgFlux Overall Central Error Uniformity Shift Calibration 2 (%) (%) (%) Factor ( sec.) ( ions/(cm s) ) Dead Time -0.683 -0.683 -0.683 0.931 2.531 4.119 -3.894 -2.307 -2.307 -2.307 -2.307 -2.307 -2.307 -0.707 0.881 2.494 -3.844 -3.844 -3.844 -3.844 -3.844 -3.844 -3.844 -3.844 -3.844 -3.844 -3.844 -3.844 -3.844 -3.844 -3.844 -3.844 -3.844 -2.244 -2.244 -0.657 -0.657 0.955 0.955 2.543 2.543 2.543 2.543 2.543 4.142 4.142 4.142 4.142 4.142 4.142 4.142 4.142 4.142 -3.87 -2.27 -0.683 -0.683 -0.683 -0.683 0.931 0.931 0.931 0.931 0.931 0.931 0.931 0.931 0.931 0.931 0.931 0.931 0.931 0.931 2.531 4.119 -3.894 -3.844 -3.844 -3.844 -3.844 -3.844 -3.844 -3.844 -2.244 -2.244 -2.244 -2.244 -2.244 -0.657 -0.657 -0.657 -0.657 0.955 0.955 0.955 0.955 0.955 2.543 2.543 2.543 2.543 -3.87 -3.87 -3.87 -3.87 -0.003 -0.003 -0.003 -0.003 0.046 0.072 2.384 2.384 2.384 2.384 2.384 2.384 2.384 2.433 2.433 2.483 -2.443 -2.443 -2.443 -2.443 -2.443 -2.443 -2.443 -2.443 -2.443 -2.443 -2.443 -2.443 -2.443 -2.443 -2.443 -2.443 -2.443 -2.418 -2.418 -2.393 -2.393 -2.393 -2.393 -2.343 -2.343 -2.343 -2.343 -2.343 -2.343 -2.343 -2.343 -2.343 -2.343 -2.343 -2.343 -2.343 -2.343 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 0.046 0.072 2.384 -2.443 -2.443 -2.443 -2.443 -2.443 -2.443 -2.443 -2.418 -2.418 -2.418 -2.418 -2.418 -2.393 -2.393 -2.393 -2.393 -2.393 -2.393 -2.393 -2.393 -2.393 -2.343 -2.343 -2.343 -2.343 -0.003 -0.003 -0.003 -0.003 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 DUT Coordinates X (in) Y (in) Z (cm) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Degree DUT Tilt Angle 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Width 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Height Aperture (inch) 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Step 56.663 56.663 56.663 56.663 56.663 56.663 56.663 56.663 56.663 56.663 56.663 56.663 56.663 56.663 56.663 56.663 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 52.075 52.075 52.075 52.075 52.075 52.075 52.075 52.075 52.075 52.075 52.075 52.075 52.075 52.075 52.075 52.075 52.075 52.075 52.075 52.075 52.075 52.075 52.075 52.075 52.075 52.075 52.075 52.075 52.075 52.075 52.075 52.075 52.075 52.075 52.075 52.075 52.075 0 0 0 0 0 0 0 18.7 18.7 18.7 18.7 18.7 48.825 48.825 48.825 48.825 55.625 55.625 55.625 55.625 55.625 59.525 59.525 59.525 59.525 59.525 59.525 59.525 59.525 Degree Al Degrader Degrader No. Angle Detector Bias (V) 727_495_526_504_700 727_495_526_504_700 727_495_526_504_700 727_495_526_504_700 727_495_526_504_700 727_495_526_504_700 727_495_526_504_700 727_495_526_504_700 727_495_526_504_700 727_495_526_504_700 727_495_526_504_700 727_495_526_504_700 727_495_526_504_700 727_495_526_504_700 727_495_526_504_700 727_495_526_504_700 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 639_425_417_396_515 711_482_505_483_664 711_482_505_483_664 711_482_505_483_664 711_482_505_483_664 711_482_505_483_664 711_482_505_483_664 711_482_505_483_664 711_482_505_483_664 711_482_505_483_664 711_482_505_483_664 711_482_505_483_664 711_482_505_483_664 711_482_505_483_664 711_482_505_483_664 711_482_505_483_664 711_482_505_483_664 711_482_505_483_664 711_482_505_483_664 711_482_505_483_664 711_482_505_483_664 711_482_505_483_664 711_482_505_483_664 711_482_505_483_664 711_482_505_483_664 711_482_505_483_664 711_482_505_483_664 711_482_505_483_664 711_482_505_483_664 711_482_505_483_664 711_482_505_483_664 711_482_505_483_664 711_482_505_483_664 711_482_505_483_664 711_482_505_483_664 711_482_505_483_664 711_482_505_483_664 711_482_505_483_664 654_437_435_414_545 654_437_435_414_545 654_437_435_414_545 654_437_435_414_545 654_437_435_414_545 654_437_435_414_545 654_437_435_414_545 677_455_462_441_590 677_455_462_441_590 677_455_462_441_590 677_455_462_441_590 677_455_462_441_590 703_475_495_473_646 703_475_495_473_646 703_475_495_473_646 703_475_495_473_646 723_491_520_498_690 723_491_520_498_690 723_491_520_498_690 723_491_520_498_690 723_491_520_498_690 743_507_546_524_737 743_507_546_524_737 743_507_546_524_737 743_507_546_524_737 743_507_546_524_737 743_507_546_524_737 743_507_546_524_737 743_507_546_524_737 Run FileName IR_March_2006.#8r IR_March_2006.#8s IR_March_2006.#8t IR_March_2006.#8u IR_March_2006.#8v IR_March_2006.#8w IR_March_2006.#8x IR_March_2006.#8y IR_March_2006.#8z IR_March_2006.#90 IR_March_2006.#91 IR_March_2006.#92 IR_March_2006.#93 IR_March_2006.#94 IR_March_2006.#95 IR_March_2006.#96 IR_March_2006.#97 IR_March_2006.#98 IR_March_2006.#99 IR_March_2006.#9a IR_March_2006.#9b IR_March_2006.#9c IR_March_2006.#9d IR_March_2006.#9e IR_March_2006.#9f IR_March_2006.#9g IR_March_2006.#9h IR_March_2006.#9i IR_March_2006.#9j IR_March_2006.#9k IR_March_2006.#9l IR_March_2006.#9m IR_March_2006.#9n IR_March_2006.#9o IR_March_2006.#9p IR_March_2006.#9q IR_March_2006.#9r IR_March_2006.#9s IR_March_2006.#9t IR_March_2006.#9u IR_March_2006.#9v IR_March_2006.#9w IR_March_2006.#9x IR_March_2006.#9y IR_March_2006.#9z IR_March_2006.#a0 IR_March_2006.#a1 IR_March_2006.#a2 IR_March_2006.#a3 IR_March_2006.#a4 IR_March_2006.#a5 IR_March_2006.#a6 IR_March_2006.#a7 IR_March_2006.#a8 IR_March_2006.#a9 IR_March_2006.#aa IR_March_2006.#ab IR_March_2006.#ac IR_March_2006.#ad IR_March_2006.#ae IR_March_2006.#af IR_March_2006.#ag IR_March_2006.#ah IR_March_2006.#ai IR_March_2006.#aj IR_March_2006.#ak IR_March_2006.#al IR_March_2006.#am IR_March_2006.#an IR_March_2006.#ao IR_March_2006.#ap IR_March_2006.#aq IR_March_2006.#ar IR_March_2006.#as IR_March_2006.#at IR_March_2006.#au IR_March_2006.#av IR_March_2006.#aw IR_March_2006.#ax IR_March_2006.#ay IR_March_2006.#az IR_March_2006.#b0 IR_March_2006.#b1 IR_March_2006.#b2 IR_March_2006.#b3 IR_March_2006.#b4 IR_March_2006.#b5 IR_March_2006.#b6 IR_March_2006.#b7 IR_March_2006.#b8 IR_March_2006.#b9 IR_March_2006.#ba IR_March_2006.#bb IR_March_2006.#bc IR_March_2006.#bd IR_March_2006.#be IR_March_2006.#bf IR_March_2006.#bg IR_March_2006.#bh IR_March_2006.#bi IR_March_2006.#bj IR_March_2006.#bk IR_March_2006.#bl IR_March_2006.#bm IR_March_2006.#bn Run # 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 384 385 386 387 388 389 390 391 392 393 394 395 396 397 398 399 400 401 402 403 404 405 406 407 408 409 410 411 412 413 414 415 416 417 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2023 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 Start Date 21:04:56 21:07:01 21:07:36 21:08:15 21:08:45 21:13:44 21:14:21 21:16:30 21:17:04 21:17:37 21:19:59 21:20:31 21:21:02 21:21:30 21:22:00 21:22:34 21:28:44 21:32:14 21:32:51 21:33:23 21:36:57 21:37:40 21:38:19 21:39:06 21:39:36 21:40:15 21:40:50 21:41:33 21:42:38 21:45:08 21:46:24 21:47:19 21:47:59 21:48:32 21:50:01 21:52:08 21:53:35 21:54:29 21:55:31 21:56:37 23:51:36 23:52:19 23:52:57 23:55:09 23:55:45 23:56:22 23:56:54 23:58:00 23:58:30 23:59:02 0:00:33 0:01:08 0:01:39 0:03:13 0:03:47 0:04:20 0:04:53 0:05:32 0:06:10 0:06:46 0:09:25 0:10:00 0:10:32 0:11:05 0:11:40 0:12:11 0:14:54 0:15:59 0:16:38 0:17:20 0:20:24 0:21:11 0:21:48 0:22:24 0:23:18 0:24:24 0:24:59 0:25:32 0:26:49 0:27:25 0:28:07 0:28:42 0:29:35 0:30:09 0:30:44 0:31:38 0:32:41 0:33:36 0:34:09 0:34:42 0:35:23 0:37:15 0:37:48 0:38:21 0:39:16 0:39:54 0:40:27 0:41:24 0:42:01 0:42:34 0:43:19 0:43:55 0:44:31 0:45:24 0:46:15 Start Time 00:00:19_(+_0_days) 00:00:21_(+_0_days) 00:00:22_(+_0_days) 00:00:19_(+_0_days) 00:00:09_(+_0_days) 00:00:22_(+_0_days) 00:00:11_(+_0_days) 00:00:18_(+_0_days) 00:00:18_(+_0_days) 00:00:16_(+_0_days) 00:00:18_(+_0_days) 00:00:17_(+_0_days) 00:00:16_(+_0_days) 00:00:17_(+_0_days) 00:00:18_(+_0_days) 00:00:19_(+_0_days) 00:00:20_(+_0_days) 00:00:19_(+_0_days) 00:00:20_(+_0_days) 00:00:20_(+_0_days) 00:00:20_(+_0_days) 00:00:19_(+_0_days) 00:00:21_(+_0_days) 00:00:20_(+_0_days) 00:00:25_(+_0_days) 00:00:20_(+_0_days) 00:00:20_(+_0_days) 00:00:21_(+_0_days) 00:00:16_(+_0_days) 00:00:13_(+_0_days) 00:00:21_(+_0_days) 00:00:20_(+_0_days) 00:00:19_(+_0_days) 00:00:26_(+_0_days) 00:00:20_(+_0_days) 00:00:19_(+_0_days) 00:00:19_(+_0_days) 00:00:18_(+_0_days) 00:00:20_(+_0_days) 00:00:24_(+_0_days) 00:00:19_(+_0_days) 00:00:18_(+_0_days) 00:00:15_(+_0_days) 00:00:20_(+_0_days) 00:00:19_(+_0_days) 00:00:19_(+_0_days) 00:00:11_(+_0_days) 00:00:19_(+_0_days) 00:00:18_(+_0_days) 00:00:09_(+_0_days) 00:00:21_(+_0_days) 00:00:18_(+_0_days) 00:00:09_(+_0_days) 00:00:19_(+_0_days) 00:00:20_(+_0_days) 00:00:21_(+_0_days) 00:00:19_(+_0_days) 00:00:20_(+_0_days) 00:00:20_(+_0_days) 00:00:23_(+_0_days) 00:00:19_(+_0_days) 00:00:21_(+_0_days) 00:00:19_(+_0_days) 00:00:19_(+_0_days) 00:00:20_(+_0_days) 00:00:07_(+_0_days) 00:00:21_(+_0_days) 00:00:19_(+_0_days) 00:00:27_(+_0_days) 00:00:09_(+_0_days) 00:00:22_(+_0_days) 00:00:20_(+_0_days) 00:00:20_(+_0_days) 00:00:19_(+_0_days) 00:00:07_(+_0_days) 00:00:20_(+_0_days) 00:00:21_(+_0_days) 00:00:11_(+_0_days) 00:00:21_(+_0_days) 00:00:20_(+_0_days) 00:00:19_(+_0_days) 00:00:06_(+_0_days) 00:00:20_(+_0_days) 00:00:20_(+_0_days) 00:00:08_(+_0_days) 00:00:15_(+_0_days) 00:00:21_(+_0_days) 00:00:20_(+_0_days) 00:00:22_(+_0_days) 00:00:20_(+_0_days) 00:00:08_(+_0_days) 00:00:22_(+_0_days) 00:00:22_(+_0_days) 00:00:12_(+_0_days) 00:00:22_(+_0_days) 00:00:20_(+_0_days) 00:00:16_(+_0_days) 00:00:21_(+_0_days) 00:00:20_(+_0_days) 00:00:07_(+_0_days) 00:00:20_(+_0_days) 00:00:20_(+_0_days) 00:00:08_(+_0_days) 00:00:25_(+_0_days) 00:00:19_(+_0_days) Run Duration 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Upset Events 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Kr 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe Selected Beam 3.944 3.542 3.542 3.542 3.542 3.038 3.038 2.111 2.111 2.111 1.003 1.003 1.003 1.003 1.003 1.003 3.254 3.254 3.254 3.254 3.254 3.254 3.254 3.254 3.254 3.254 3.254 3.254 3.254 3.254 3.254 3.254 3.254 3.254 3.254 3.254 3.254 3.254 3.254 3.254 1.601 1.601 1.601 1.601 1.601 1.601 1.601 1.601 1.601 1.601 1.601 1.601 1.601 1.601 1.601 1.601 1.601 1.601 1.601 1.601 1.601 1.601 1.601 1.601 1.601 1.601 1.601 1.601 1.601 1.601 1.601 1.601 1.601 1.601 1.601 1.601 1.601 1.601 1.601 1.601 1.601 1.601 1.601 1.601 1.601 1.601 1.601 1.601 1.601 1.601 1.601 1.601 1.601 1.601 1.601 1.601 1.601 1.601 1.601 1.601 1.601 1.601 1.601 1.601 1.601 ( µm ) Al Thk 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) # of Layers ( Filename ) 2.8 4.1 4.1 4.1 4.1 5.6 5.6 8.1 8.1 8.1 10.8 10.8 10.8 10.8 10.8 10.8 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 8.2 8.2 8.2 8.2 8.2 8.2 8.2 8.2 8.2 8.2 8.2 8.2 8.2 8.2 8.2 8.2 8.2 8.2 8.2 8.2 8.2 8.2 8.2 8.2 8.2 8.2 8.2 8.2 8.2 8.2 8.2 8.2 8.2 8.2 8.2 8.2 8.2 8.2 8.2 8.2 8.2 8.2 8.2 8.2 8.2 8.2 8.2 8.2 8.2 8.2 8.2 8.2 8.2 8.2 8.2 8.2 8.2 8.2 8.2 8.2 8.2 8.2 8.2 8.2 8.2 (MeV/amu) 234 342 342 342 342 469 469 679 679 679 905 905 905 905 905 905 416 416 416 416 416 416 416 416 416 416 416 416 416 416 416 416 416 416 416 416 416 416 416 416 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 (MeV) Beam Energy silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon 40.5 38.4 38.4 38.4 38.4 36 36 32.4 32.4 32.4 29.4 29.4 29.4 29.4 29.4 29.4 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 30.3 42.1 42.1 42.1 42.1 56.7 56.7 83.3 83.3 83.3 114.9 114.9 114.9 114.9 114.9 114.9 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 40.5 38.4 38.4 38.4 38.4 36 36 32.4 32.4 32.4 29.4 29.4 29.4 29.4 29.4 29.4 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 30.3 42.1 42.1 42.1 42.1 56.7 56.7 83.3 83.3 83.3 114.9 114.9 114.9 114.9 114.9 114.9 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 50.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 20 In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current 2.95E+05 3.00E+05 2.98E+05 2.95E+05 8.36E+04 2.98E+05 1.10E+05 3.01E+05 2.98E+05 2.16E+05 3.04E+05 3.06E+05 2.92E+05 2.95E+05 2.98E+05 3.03E+05 2.90E+05 3.09E+05 2.97E+05 3.06E+05 2.98E+05 3.02E+05 3.04E+05 2.91E+05 2.97E+05 2.96E+05 3.01E+05 3.10E+05 2.10E+05 1.67E+05 3.10E+05 2.96E+05 3.05E+05 2.98E+05 3.11E+05 3.00E+05 2.90E+05 2.95E+05 3.02E+05 3.11E+05 3.10E+05 3.09E+05 2.44E+05 2.90E+05 2.90E+05 2.96E+05 4.42E+04 3.06E+05 2.96E+05 8.21E+04 3.08E+05 3.04E+05 8.81E+04 2.97E+05 3.08E+05 2.93E+05 3.02E+05 3.09E+05 2.93E+05 3.09E+05 2.94E+05 2.99E+05 2.97E+05 2.97E+05 2.98E+05 4.82E+04 2.93E+05 2.98E+05 3.02E+05 5.68E+04 2.96E+05 2.98E+05 2.98E+05 2.92E+05 6.42E+04 3.00E+05 2.93E+05 1.29E+05 3.08E+05 3.07E+05 2.94E+05 4.52E+04 3.05E+05 2.95E+05 6.79E+04 2.18E+05 2.91E+05 2.95E+05 3.08E+05 3.01E+05 5.06E+04 2.99E+05 3.01E+05 1.37E+05 3.10E+05 3.00E+05 1.95E+05 2.98E+05 3.05E+05 2.02E+04 3.05E+05 2.98E+05 6.27E+04 3.09E+05 3.02E+05 Nominal Nominal Effective Effective Effective Target LET Range LET Range DUT Position Fluence 2 (MeV.cm /mg) Material (MeV.cm2/mg) Location Name ( ions/cm2 ) ( µm ) ( µm ) 1.92E+02 1.85E+02 1.84E+02 1.82E+02 5.14E+01 1.72E+02 6.32E+01 1.56E+02 1.55E+02 1.12E+02 1.43E+02 1.44E+02 1.38E+02 1.39E+02 1.41E+02 1.43E+02 1.72E+02 1.83E+02 1.76E+02 1.82E+02 1.77E+02 1.79E+02 1.80E+02 1.73E+02 1.76E+02 1.76E+02 1.78E+02 1.84E+02 1.24E+02 9.93E+01 1.84E+02 1.76E+02 1.81E+02 1.76E+02 1.84E+02 1.78E+02 1.72E+02 1.75E+02 1.79E+02 1.84E+02 2.79E+02 2.78E+02 2.20E+02 2.61E+02 2.61E+02 2.67E+02 3.98E+01 2.76E+02 2.67E+02 7.39E+01 2.78E+02 2.74E+02 7.93E+01 2.67E+02 2.78E+02 2.63E+02 2.72E+02 2.78E+02 2.64E+02 2.78E+02 2.65E+02 2.69E+02 2.67E+02 2.67E+02 2.68E+02 4.34E+01 2.64E+02 2.69E+02 2.72E+02 5.11E+01 2.66E+02 2.68E+02 2.68E+02 2.63E+02 5.78E+01 2.70E+02 2.64E+02 1.16E+02 2.77E+02 2.77E+02 2.64E+02 4.07E+01 2.75E+02 2.66E+02 6.12E+01 1.96E+02 2.62E+02 2.66E+02 2.77E+02 2.71E+02 4.56E+01 2.69E+02 2.71E+02 1.23E+02 2.79E+02 2.70E+02 1.76E+02 2.69E+02 2.75E+02 1.82E+01 2.74E+02 2.69E+02 5.65E+01 2.79E+02 2.72E+02 ( rad ) Dose International Rectifier Corp. SEE Test Report March 2006 – T.A.M.U. 14.8 15.4667 15.3 14.7667 4.56667 16.2667 5.15 13.5 13.25 9.5 13.1833 13.3 12.5167 13 13.5667 14.4333 14.9833 15 15.0833 16.0667 13.85 14.3667 14.5 14.3667 16.5167 14.85 14.6833 15.0167 10.45 8.35 14.8333 14.45 14.4 14 14.35 14.5333 13.5333 13.7333 14.5833 14.8833 14 13.8333 11.5333 13.9167 13.5167 13.6 2.48333 14.6833 13.45 4.08333 15.35 14.2833 4.5 14.3333 14.7667 14.3167 14.3 14.8833 14.5667 15.3167 14.3667 15.15 14.8 14.7667 14.5333 2.68333 15.2167 14.5333 15.2667 3.3 14.85 14.95 14.95 15.0167 3.58333 15.6167 15.55 7.03333 16.3167 15.8167 14.95 2.63333 15.45 15.1333 3.93333 11.2833 16.2833 15.1167 16.4167 15.95 2.98333 15.5333 15.7833 7.43333 15.9667 15.8667 10.35 16.1 15.6 1.41667 15.6833 15.4333 3.53333 16.15 14.0667 ( sec.) Live Time 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2.00E+04 1.94E+04 1.95E+04 2.00E+04 1.83E+04 1.84E+04 2.13E+04 2.23E+04 2.25E+04 2.28E+04 2.31E+04 2.30E+04 2.34E+04 2.27E+04 2.20E+04 2.10E+04 1.94E+04 2.06E+04 1.97E+04 1.91E+04 2.15E+04 2.10E+04 2.10E+04 2.03E+04 1.80E+04 2.00E+04 2.05E+04 2.06E+04 2.01E+04 2.01E+04 2.09E+04 2.05E+04 2.12E+04 2.13E+04 2.17E+04 2.07E+04 2.14E+04 2.15E+04 2.07E+04 2.09E+04 2.22E+04 2.24E+04 2.12E+04 2.09E+04 2.15E+04 2.18E+04 1.78E+04 2.09E+04 2.20E+04 2.01E+04 2.01E+04 2.13E+04 1.96E+04 2.07E+04 2.09E+04 2.04E+04 2.11E+04 2.07E+04 2.01E+04 2.02E+04 2.05E+04 1.98E+04 2.01E+04 2.01E+04 2.05E+04 1.80E+04 1.93E+04 2.05E+04 1.98E+04 1.72E+04 1.99E+04 1.99E+04 1.99E+04 1.94E+04 1.79E+04 1.92E+04 1.89E+04 1.84E+04 1.89E+04 1.94E+04 1.97E+04 1.72E+04 1.98E+04 1.95E+04 1.73E+04 1.93E+04 1.79E+04 1.95E+04 1.87E+04 1.89E+04 1.70E+04 1.93E+04 1.91E+04 1.84E+04 1.94E+04 1.89E+04 1.88E+04 1.85E+04 1.96E+04 1.42E+04 1.94E+04 1.93E+04 1.78E+04 1.92E+04 2.15E+04 Average Flux 0.58 0.58 0.58 0.58 1.1 0.58 0.96 0.58 0.58 0.68 0.57 0.57 0.58 0.58 0.58 0.57 0.59 0.57 0.58 0.57 0.58 0.58 0.57 0.59 0.58 0.58 0.58 0.57 0.69 0.77 0.57 0.58 0.57 0.58 0.57 0.58 0.59 0.58 0.58 0.57 0.57 0.57 0.64 0.59 0.59 0.58 1.5 0.57 0.58 1.1 0.57 0.57 1.1 0.58 0.57 0.58 0.58 0.57 0.58 0.57 0.58 0.58 0.58 0.58 0.58 1.4 0.58 0.58 0.58 1.3 0.58 0.58 0.58 0.59 1.2 0.58 0.58 0.88 0.57 0.57 0.58 1.5 0.57 0.58 1.2 0.68 0.59 0.58 0.57 0.58 1.4 0.58 0.58 0.86 0.57 0.58 0.72 0.58 0.57 2.2 0.57 0.58 1.3 0.57 0.58 90 88 88 88 90 87 88 86 87 88 88 89 89 88 90 90 89 88 87 88 90 88 89 89 88 88 88 88 89 89 88 89 90 90 91 89 90 90 89 89 94 94 94 95 95 94 98 94 95 97 94 96 97 95 95 95 95 95 95 94 95 95 95 94 95 97 95 95 95 95 94 94 94 94 95 94 93 94 94 93 93 96 93 93 95 94 93 93 93 93 95 93 93 94 94 94 94 94 94 96 93 94 96 94 90 6 8 8 8 7 9 8 10 9 9 8 8 7 8 6 6 6 8 8 8 6 8 7 6 7 8 8 8 6 6 7 7 6 5 5 7 6 6 6 6 1 2 2 1 1 2 1 2 2 2 2 1 1 2 1 1 1 2 1 1 1 1 1 2 1 1 2 1 1 2 2 2 2 2 2 2 2 2 2 2 3 2 2 2 3 2 2 2 2 3 2 3 2 1 2 2 2 2 2 3 2 2 2 1 7 1.39964 1.34817 1.3674 1.37116 1.36902 1.07665 1.29684 1.20103 1.20133 1.20602 1.1109 1.10418 1.11093 1.09699 1.09277 1.06114 1.31558 1.33799 1.33919 1.33004 1.33575 1.3363 1.33921 1.32865 1.36191 1.31705 1.34228 1.33928 1.32282 1.32282 1.32695 1.33846 1.32544 1.32845 1.3447 1.33453 1.34387 1.32759 1.32751 1.31962 1.06646 1.06301 1.0783 1.06904 1.06618 1.06617 1.06589 1.07359 1.08264 1.06843 1.06462 1.09469 1.07993 1.07815 1.08083 1.05766 1.09933 1.08078 1.06732 1.08295 1.08824 1.0697 1.08927 1.0789 1.07137 1.09979 1.06681 1.077 1.06315 1.07849 1.05924 1.0425 1.07027 1.05422 1.07832 1.07124 1.0759 1.07012 1.07051 1.06738 1.07622 1.087 1.07765 1.07908 1.06055 1.07382 1.05795 1.07369 1.06628 1.0767 1.08361 1.07642 1.06723 1.07681 1.07866 1.05591 1.07021 1.0594 1.09109 1.08338 1.08338 1.0772 1.08263 1.0738 1.12768 Overall AvgFlux Overall Central Error Uniformity Shift Calibration 2 (%) (%) (%) Factor ( sec.) ( ions/(cm s) ) Dead Time -3.87 -2.596 -2.596 -2.596 -2.596 -0.683 -0.683 0.931 0.931 0.931 2.531 2.531 2.531 2.531 2.531 2.531 -3.894 -3.894 -3.894 -3.894 -3.894 -3.894 -3.894 -3.894 -3.894 -3.894 -3.894 -3.894 -3.894 -2.307 -0.707 -0.707 -0.707 -0.707 0.881 2.494 4.094 4.094 2.494 0.881 -3.844 -3.844 -3.844 -2.244 -2.244 -2.244 -2.244 -0.657 -0.657 -0.657 0.955 0.955 0.955 2.543 2.543 2.543 2.543 2.543 2.543 2.543 2.543 2.543 2.543 2.543 2.543 2.543 4.142 4.142 4.142 4.142 -3.87 -3.87 -3.87 -3.87 -3.87 -2.27 -2.27 -2.27 -0.683 -0.683 -0.683 -0.683 0.931 0.931 0.931 2.531 4.119 4.119 4.119 4.119 4.119 -3.894 -3.894 -3.894 -2.307 -2.307 -2.307 -0.707 -0.707 -0.707 0.881 0.881 0.881 2.494 2.494 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 0.046 0.046 0.046 0.046 0.046 0.046 2.384 2.384 2.384 2.384 2.384 2.384 2.384 2.384 2.384 2.384 2.384 2.384 2.384 2.384 2.433 2.433 2.433 2.433 2.433 2.483 2.508 2.508 2.483 2.433 -2.443 -2.443 -2.443 -2.418 -2.418 -2.418 -2.418 -2.393 -2.393 -2.393 -2.393 -2.393 -2.393 -2.343 -2.343 -2.343 -2.343 -2.343 -2.343 -2.343 -2.343 -2.343 -2.343 -2.343 -2.343 -2.343 -2.343 -2.343 -2.343 -2.343 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 0.046 0.072 0.072 0.072 0.072 0.072 2.384 2.384 2.384 2.384 2.384 2.384 2.433 2.433 2.433 2.433 2.433 2.433 2.483 2.483 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 DUT Coordinates X (in) Y (in) Z (cm) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Degree DUT Tilt Angle 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Width 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Height Aperture (inch) 2 2 2 2 2 2 2 2 2 2 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Step 59.525 55.625 55.625 55.625 55.625 48.825 48.825 18.7 18.7 18.7 4.2 4.2 4.2 4.2 4.2 4.2 52.075 52.075 52.075 52.075 52.075 52.075 52.075 52.075 52.075 52.075 52.075 52.075 52.075 52.075 52.075 52.075 52.075 52.075 52.075 52.075 52.075 52.075 52.075 52.075 51.338 51.338 51.338 51.338 51.338 51.338 51.338 51.338 51.338 51.338 51.338 51.338 51.338 51.338 51.338 51.338 51.338 51.338 51.338 51.338 51.338 51.338 51.338 51.338 51.338 51.338 51.338 51.338 51.338 51.338 51.338 51.338 51.338 51.338 51.338 51.338 51.338 51.338 51.338 51.338 51.338 51.338 51.338 51.338 51.338 51.338 51.338 51.338 51.338 51.338 51.338 51.338 51.338 51.338 51.338 51.338 51.338 51.338 51.338 51.338 51.338 51.338 51.338 51.338 51.338 Degree Al Degrader Degrader No. Angle Detector Bias (V) 743_507_546_524_737 723_491_520_498_690 723_491_520_498_690 723_491_520_498_690 723_491_520_498_690 703_475_495_473_646 703_475_495_473_646 677_455_462_441_590 677_455_462_441_590 677_455_462_441_590 654_437_435_414_545 654_437_435_414_545 654_437_435_414_545 654_437_435_414_545 654_437_435_414_545 654_437_435_414_545 711_482_505_483_664 711_482_505_483_664 711_482_505_483_664 711_482_505_483_664 711_482_505_483_664 711_482_505_483_664 711_482_505_483_664 711_482_505_483_664 711_482_505_483_664 711_482_505_483_664 711_482_505_483_664 711_482_505_483_664 711_482_505_483_664 711_482_505_483_664 711_482_505_483_664 711_482_505_483_664 711_482_505_483_664 711_482_505_483_664 711_482_505_483_664 711_482_505_483_664 711_482_505_483_664 711_482_505_483_664 711_482_505_483_664 711_482_505_483_664 599_545_642_666_419 599_545_642_666_419 599_545_642_666_419 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 Run FileName IR_March_2006.#bo IR_March_2006.#bp IR_March_2006.#bq IR_March_2006.#br IR_March_2006.#bs IR_March_2006.#bt IR_March_2006.#bu IR_March_2006.#bv IR_March_2006.#bw IR_March_2006.#bx IR_March_2006.#by IR_March_2006.#bz IR_March_2006.#c0 IR_March_2006.#c1 IR_March_2006.#c2 IR_March_2006.#c3 IR_March_2006.#c4 IR_March_2006.#c5 IR_March_2006.#c6 IR_March_2006.#c7 IR_March_2006.#c8 IR_March_2006.#c9 IR_March_2006.#ca IR_March_2006.#cb IR_March_2006.#cc IR_March_2006.#cd IR_March_2006.#ce IR_March_2006.#cf IR_March_2006.#cg IR_March_2006.#ch IR_March_2006.#ci IR_March_2006.#cj IR_March_2006.#ck IR_March_2006.#cl IR_March_2006.#cm IR_March_2006.#cn IR_March_2006.#co IR_March_2006.#cp IR_March_2006.#cq IR_March_2006.#cr IR_March_2006.#cs IR_March_2006.#ct IR_March_2006.#cu IR_March_2006.#cv IR_March_2006.#cw IR_March_2006.#cx IR_March_2006.#cy IR_March_2006.#cz IR_March_2006.#d0 IR_March_2006.#d1 IR_March_2006.#d2 IR_March_2006.#d3 IR_March_2006.#d4 IR_March_2006.#d5 IR_March_2006.#d6 IR_March_2006.#d7 IR_March_2006.#d8 IR_March_2006.#d9 IR_March_2006.#da IR_March_2006.#db IR_March_2006.#dc IR_March_2006.#dd IR_March_2006.#de IR_March_2006.#df IR_March_2006.#dg IR_March_2006.#dh IR_March_2006.#di IR_March_2006.#dj IR_March_2006.#dk IR_March_2006.#dl IR_March_2006.#dm IR_March_2006.#dn IR_March_2006.#do IR_March_2006.#dp IR_March_2006.#dq IR_March_2006.#dr IR_March_2006.#ds IR_March_2006.#dt IR_March_2006.#du IR_March_2006.#dv IR_March_2006.#dw IR_March_2006.#dx IR_March_2006.#dy IR_March_2006.#dz IR_March_2006.#e0 IR_March_2006.#e1 IR_March_2006.#e2 IR_March_2006.#e3 IR_March_2006.#e4 IR_March_2006.#e5 IR_March_2006.#e6 IR_March_2006.#e7 IR_March_2006.#e8 IR_March_2006.#e9 IR_March_2006.#ea IR_March_2006.#eb IR_March_2006.#ec IR_March_2006.#ed IR_March_2006.#ee IR_March_2006.#ef IR_March_2006.#eg IR_March_2006.#eh IR_March_2006.#ei IR_March_2006.#ej IR_March_2006.#ek Run # 418 419 420 421 422 423 424 425 426 427 428 429 430 431 432 433 434 435 436 437 438 439 440 441 442 443 444 445 446 447 448 449 450 451 452 453 454 455 456 457 458 459 460 461 462 463 464 465 466 467 468 469 470 471 472 473 474 475 476 477 478 479 480 481 482 483 484 485 486 487 488 489 490 491 492 493 494 495 496 497 498 499 500 501 502 503 504 505 506 507 508 510 511 512 514 515 516 517 518 519 520 521 522 523 524 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 Start Date 0:46:50 0:47:51 0:48:24 0:48:57 0:49:32 1:25:30 1:26:24 1:27:26 1:28:53 1:30:09 1:32:59 1:36:42 1:37:34 1:40:28 1:41:27 1:43:48 1:44:42 1:45:38 1:51:26 1:52:11 1:52:48 1:53:23 1:53:57 1:57:14 1:57:58 1:58:36 2:01:17 2:02:01 2:03:05 2:03:41 2:04:16 2:04:59 2:05:33 2:07:36 2:08:18 2:08:56 2:20:27 2:21:01 2:24:28 2:25:04 2:25:41 2:26:18 2:26:50 2:27:21 2:29:01 2:30:18 3:13:16 3:15:11 3:15:41 3:16:12 3:16:44 3:17:17 3:18:02 3:18:39 3:19:07 3:19:36 3:21:14 3:21:50 3:24:24 3:24:57 3:25:27 3:26:00 3:27:32 3:29:12 3:29:44 3:31:20 3:31:52 3:32:20 3:32:49 3:35:11 3:35:43 3:36:54 3:37:30 3:38:03 3:38:41 3:39:39 3:40:26 3:50:46 3:58:02 3:59:42 4:01:32 4:02:08 4:03:23 4:04:07 4:04:53 4:51:50 4:53:46 4:57:39 5:00:19 5:05:34 5:06:16 5:10:52 5:11:25 5:11:59 5:18:55 5:20:32 5:22:26 6:57:08 7:00:59 7:02:36 7:21:46 7:22:54 7:31:24 7:32:39 7:34:47 Start Time 00:00:16_(+_0_days) 00:00:19_(+_0_days) 00:00:18_(+_0_days) 00:00:18_(+_0_days) 00:00:09_(+_0_days) 00:00:21_(+_0_days) 00:00:21_(+_0_days) 00:00:20_(+_0_days) 00:00:17_(+_0_days) 00:00:22_(+_0_days) 00:00:31_(+_0_days) 00:00:10_(+_0_days) 00:00:22_(+_0_days) 00:00:20_(+_0_days) 00:00:12_(+_0_days) 00:00:22_(+_0_days) 00:00:22_(+_0_days) 00:00:20_(+_0_days) 00:00:21_(+_0_days) 00:00:22_(+_0_days) 00:00:22_(+_0_days) 00:00:21_(+_0_days) 00:00:08_(+_0_days) 00:00:22_(+_0_days) 00:00:23_(+_0_days) 00:00:11_(+_0_days) 00:00:23_(+_0_days) 00:00:23_(+_0_days) 00:00:20_(+_0_days) 00:00:20_(+_0_days) 00:00:19_(+_0_days) 00:00:17_(+_0_days) 00:00:08_(+_0_days) 00:00:22_(+_0_days) 00:00:19_(+_0_days) 00:00:23_(+_0_days) 00:00:20_(+_0_days) 00:00:12_(+_0_days) 00:00:23_(+_0_days) 00:00:22_(+_0_days) 00:00:20_(+_0_days) 00:00:19_(+_0_days) 00:00:18_(+_0_days) 00:00:14_(+_0_days) 00:00:20_(+_0_days) 00:00:13_(+_0_days) 00:00:20_(+_0_days) 00:00:19_(+_0_days) 00:00:20_(+_0_days) 00:00:19_(+_0_days) 00:00:20_(+_0_days) 00:00:19_(+_0_days) 00:00:19_(+_0_days) 00:00:19_(+_0_days) 00:00:19_(+_0_days) 00:00:17_(+_0_days) 00:00:21_(+_0_days) 00:00:11_(+_0_days) 00:00:18_(+_0_days) 00:00:17_(+_0_days) 00:00:18_(+_0_days) 00:00:18_(+_0_days) 00:00:08_(+_0_days) 00:00:18_(+_0_days) 00:00:19_(+_0_days) 00:00:18_(+_0_days) 00:00:19_(+_0_days) 00:00:18_(+_0_days) 00:00:10_(+_0_days) 00:00:20_(+_0_days) 00:00:23_(+_0_days) 00:00:21_(+_0_days) 00:00:22_(+_0_days) 00:00:23_(+_0_days) 00:00:23_(+_0_days) 00:00:37_(+_0_days) 00:00:23_(+_0_days) 00:00:19_(+_0_days) 00:00:26_(+_0_days) 00:00:20_(+_0_days) 00:00:22_(+_0_days) 00:00:21_(+_0_days) 00:00:21_(+_0_days) 00:00:31_(+_0_days) 00:00:20_(+_0_days) 00:00:11_(+_0_days) 00:00:18_(+_0_days) 00:00:19_(+_0_days) 00:00:19_(+_0_days) 00:00:20_(+_0_days) 00:00:20_(+_0_days) 00:00:19_(+_0_days) 00:00:20_(+_0_days) 00:00:17_(+_0_days) 00:00:19_(+_0_days) 00:00:20_(+_0_days) 00:00:18_(+_0_days) 00:00:53_(+_0_days) 00:00:59_(+_0_days) 00:01:00_(+_0_days) 00:00:20_(+_0_days) 00:00:29_(+_0_days) 00:00:22_(+_0_days) 00:00:21_(+_0_days) 00:00:20_(+_0_days) Run Duration 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Upset Events 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe Selected Beam 1.601 1.601 1.601 1.601 1.601 1.601 1.601 1.601 1.601 1.601 1.601 1.601 1.601 1.601 1.601 1.601 1.601 1.601 1 1 1 1 1 1 1 1 2.543 2.543 2.543 2.543 2.543 2.543 2.543 2.543 2.543 2.543 2.543 2.543 2.882 2.882 2.882 2.882 2.882 2.882 2.882 2.882 2.543 2.543 2.543 2.543 2.543 2.543 2.543 2.543 2.543 2.543 2.543 2.543 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 2.543 2.543 2.543 2.543 2.543 2.543 2.543 2.543 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 ( µm ) Al Thk 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) # of Layers ( Filename ) 8.2 8.2 8.2 8.2 8.2 8.2 8.2 8.2 8.2 8.2 8.2 8.2 8.2 8.2 8.2 8.2 8.2 8.2 9.9 9.9 9.9 9.9 9.9 9.9 9.9 9.9 5.4 5.4 5.4 5.4 5.4 5.4 5.4 5.4 5.4 5.4 5.4 5.4 4.3 4.3 4.3 4.3 4.3 4.3 4.3 4.3 5.4 5.4 5.4 5.4 5.4 5.4 5.4 5.4 5.4 5.4 5.4 5.4 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 5.4 5.4 5.4 5.4 5.4 5.4 5.4 5.4 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 (MeV/amu) 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1060 1279 1279 1279 1279 1279 1279 1279 1279 693 693 693 693 693 693 693 693 693 693 693 693 553 553 553 553 553 553 553 553 693 693 693 693 693 693 693 693 693 693 693 693 924 924 924 924 924 924 924 924 924 924 924 693 693 693 693 693 693 693 693 924 924 924 924 924 924 924 924 924 924 924 924 924 924 924 924 924 924 924 924 924 924 924 924 924 924 924 924 (MeV) Beam Energy silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 53.7 53.7 53.7 53.7 53.7 53.7 53.7 53.7 60.5 60.5 60.5 60.5 60.5 60.5 60.5 60.5 60.5 60.5 60.5 60.5 62 62 62 62 62 62 62 62 60.5 60.5 60.5 60.5 60.5 60.5 60.5 60.5 60.5 60.5 60.5 60.5 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 60.5 60.5 60.5 60.5 60.5 60.5 60.5 60.5 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 100.7 100.7 100.7 100.7 100.7 100.7 100.7 100.7 56.4 56.4 56.4 56.4 56.4 56.4 56.4 56.4 56.4 56.4 56.4 56.4 46.5 46.5 46.5 46.5 46.5 46.5 46.5 46.5 56.4 56.4 56.4 56.4 56.4 56.4 56.4 56.4 56.4 56.4 56.4 56.4 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 56.4 56.4 56.4 56.4 56.4 56.4 56.4 56.4 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 56.2 53.7 53.7 53.7 53.7 53.7 53.7 53.7 53.7 60.5 60.5 60.5 60.5 60.5 60.5 60.5 60.5 60.5 60.5 60.5 60.5 62 62 62 62 62 62 62 62 60.5 60.5 60.5 60.5 60.5 60.5 60.5 60.5 60.5 60.5 60.5 60.5 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 60.5 60.5 60.5 60.5 60.5 60.5 60.5 60.5 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 83.5 100.7 100.7 100.7 100.7 100.7 100.7 100.7 100.7 56.4 56.4 56.4 56.4 56.4 56.4 56.4 56.4 56.4 56.4 56.4 56.4 46.5 46.5 46.5 46.5 46.5 46.5 46.5 46.5 56.4 56.4 56.4 56.4 56.4 56.4 56.4 56.4 56.4 56.4 56.4 56.4 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 56.4 56.4 56.4 56.4 56.4 56.4 56.4 56.4 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 21 In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current 2.22E+05 3.09E+05 3.10E+05 3.03E+05 7.04E+04 2.96E+05 3.07E+05 2.93E+05 2.06E+05 2.92E+05 2.65E+05 8.77E+04 3.08E+05 3.06E+05 1.43E+05 3.06E+05 3.09E+05 2.91E+05 3.02E+05 2.98E+05 2.96E+05 2.96E+05 5.32E+04 3.05E+05 3.01E+05 1.08E+05 3.06E+05 3.07E+05 3.01E+05 3.04E+05 3.00E+05 2.96E+05 8.00E+04 2.93E+05 3.00E+05 3.08E+05 3.11E+05 1.14E+05 3.10E+05 3.00E+05 3.08E+05 3.01E+05 3.03E+05 2.04E+05 3.02E+05 1.15E+05 3.02E+05 2.99E+05 3.03E+05 2.98E+05 3.10E+05 2.96E+05 3.11E+05 2.94E+05 2.91E+05 3.04E+05 3.06E+05 1.42E+05 2.90E+05 2.89E+05 3.00E+05 3.02E+05 6.57E+04 2.90E+05 3.02E+05 3.05E+05 2.93E+05 2.94E+05 9.67E+04 3.08E+05 2.98E+05 2.94E+05 3.01E+05 3.05E+05 3.04E+05 3.00E+05 3.00E+05 3.01E+05 3.03E+05 2.93E+05 3.07E+05 3.02E+05 2.92E+05 2.93E+05 2.96E+05 7.91E+04 2.89E+05 3.01E+05 2.94E+05 2.96E+05 2.96E+05 2.92E+05 2.97E+05 2.91E+05 3.11E+05 2.96E+05 3.09E+05 3.00E+05 2.99E+05 3.01E+05 3.03E+05 3.06E+05 3.08E+05 3.03E+05 3.06E+05 Nominal Nominal Effective Effective Effective Target LET Range LET Range DUT Position Fluence 2 (MeV.cm /mg) Material (MeV.cm2/mg) Location Name ( ions/cm2 ) ( µm ) ( µm ) 2.00E+02 2.79E+02 2.79E+02 2.73E+02 6.34E+01 2.66E+02 2.76E+02 2.64E+02 1.85E+02 2.63E+02 2.38E+02 7.90E+01 2.77E+02 2.76E+02 1.29E+02 2.76E+02 2.78E+02 2.62E+02 2.60E+02 2.56E+02 2.55E+02 2.54E+02 4.58E+01 2.62E+02 2.59E+02 9.29E+01 2.97E+02 2.97E+02 2.92E+02 2.94E+02 2.91E+02 2.87E+02 7.76E+01 2.84E+02 2.90E+02 2.98E+02 3.01E+02 1.11E+02 3.08E+02 2.98E+02 3.05E+02 2.99E+02 3.01E+02 2.03E+02 3.00E+02 1.14E+02 2.92E+02 2.90E+02 2.94E+02 2.89E+02 3.00E+02 2.87E+02 3.02E+02 2.85E+02 2.82E+02 2.95E+02 2.97E+02 1.38E+02 2.69E+02 2.67E+02 2.78E+02 2.80E+02 6.09E+01 2.68E+02 2.80E+02 2.82E+02 2.72E+02 2.72E+02 8.96E+01 2.99E+02 2.89E+02 2.84E+02 2.92E+02 2.95E+02 2.95E+02 2.91E+02 2.90E+02 2.79E+02 2.80E+02 2.71E+02 2.84E+02 2.80E+02 2.71E+02 2.71E+02 2.74E+02 7.32E+01 2.68E+02 2.79E+02 2.73E+02 2.74E+02 2.74E+02 2.71E+02 2.75E+02 2.70E+02 2.88E+02 2.74E+02 2.86E+02 2.77E+02 2.77E+02 2.79E+02 2.81E+02 2.83E+02 2.85E+02 2.81E+02 2.83E+02 ( rad ) Dose International Rectifier Corp. SEE Test Report March 2006 – T.A.M.U. 10.3667 14.45 13.95 14.1 3.86667 15.7 16.1333 16 11.4333 16.2833 14.85 5.41667 18.45 15.85 7.46667 16.7167 16.9167 15.55 16.4167 16.5667 16.8 16.4833 3.33333 17.5167 17.8833 6.2 18.3333 18.85 14.5833 14.35 13.8333 13.8 4.03333 13.5333 13.9167 14.3667 14.05 5.56667 14.4833 14.0833 14.5167 13.8833 13.9 9.85 14.7333 6.35 14.8333 14.7 14.3 13.8833 14.25 13.7333 14.2833 13.2667 12.95 13.7333 13.35 6.38333 12.9667 12.7333 13.55 13.8167 3.26667 13.4667 14.6667 13.95 13.75 13.6667 4.75 15.4667 15.8167 16.2167 17.1167 18.1333 18.05 18 18.8 14.3333 18.3167 15.45 16 16.1167 14.9667 15.2333 14.9167 3.61667 12.5667 13.8167 13.2 13.3667 13.9167 13.6 14.2833 13.3833 13.6 13.2833 13.9333 41.1833 53.8667 54.6667 14.1667 14.45 15.3167 15.1833 15.5833 ( sec.) Live Time 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2.14E+04 2.14E+04 2.22E+04 2.15E+04 1.82E+04 1.89E+04 1.90E+04 1.83E+04 1.80E+04 1.79E+04 1.78E+04 1.62E+04 1.67E+04 1.93E+04 1.92E+04 1.83E+04 1.83E+04 1.87E+04 1.84E+04 1.80E+04 1.76E+04 1.79E+04 1.60E+04 1.74E+04 1.68E+04 1.74E+04 1.67E+04 1.63E+04 2.06E+04 2.12E+04 2.17E+04 2.14E+04 1.98E+04 2.16E+04 2.15E+04 2.14E+04 2.21E+04 2.05E+04 2.14E+04 2.13E+04 2.12E+04 2.17E+04 2.18E+04 2.07E+04 2.05E+04 1.81E+04 2.03E+04 2.04E+04 2.12E+04 2.15E+04 2.18E+04 2.15E+04 2.18E+04 2.22E+04 2.25E+04 2.21E+04 2.29E+04 2.22E+04 2.24E+04 2.27E+04 2.22E+04 2.18E+04 2.01E+04 2.15E+04 2.06E+04 2.19E+04 2.13E+04 2.15E+04 2.04E+04 1.99E+04 1.89E+04 1.81E+04 1.76E+04 1.68E+04 1.69E+04 1.67E+04 1.59E+04 2.10E+04 1.65E+04 1.90E+04 1.92E+04 1.88E+04 1.95E+04 1.92E+04 1.99E+04 2.19E+04 2.30E+04 2.18E+04 2.23E+04 2.22E+04 2.12E+04 2.15E+04 2.08E+04 2.18E+04 2.29E+04 2.23E+04 2.21E+04 7.27E+03 5.55E+03 5.51E+03 2.14E+04 2.12E+04 2.01E+04 2.00E+04 1.96E+04 Average Flux 0.67 0.57 0.57 0.57 1.2 0.58 0.57 0.58 0.7 0.59 0.61 1.1 0.57 0.57 0.84 0.57 0.57 0.59 0.58 0.58 0.58 0.58 1.4 0.57 0.58 0.96 0.57 0.57 0.58 0.57 0.58 0.58 1.1 0.58 0.58 0.57 0.57 0.94 0.57 0.58 0.57 0.58 0.57 0.7 0.58 0.93 0.58 0.58 0.57 0.58 0.57 0.58 0.57 0.58 0.59 0.57 0.57 0.84 0.59 0.59 0.58 0.58 1.2 0.59 0.58 0.57 0.58 0.58 1 0.57 0.58 0.58 0.58 0.57 0.57 0.58 0.58 0.58 0.57 0.58 0.57 0.58 0.58 0.58 0.58 1.1 0.59 0.58 0.58 0.58 0.58 0.58 0.58 0.59 0.57 0.58 0.57 0.58 0.58 0.58 0.57 0.57 0.57 0.57 0.57 89 89 89 88 89 88 89 89 88 89 88 89 90 92 92 92 92 92 92 92 92 93 92 91 92 92 92 92 93 93 93 93 93 93 93 93 93 94 93 93 93 93 92 93 93 93 85 86 85 85 84 85 85 84 85 85 85 86 86 86 86 86 86 87 86 87 87 87 87 86 87 88 88 88 88 89 88 95 95 97 96 97 96 95 95 95 96 97 96 97 97 97 97 97 94 95 94 90 88 89 87 87 86 87 87 8 8 8 9 9 9 8 8 9 8 9 8 7 6 6 6 6 6 5 5 6 5 6 6 6 6 4 4 4 4 4 4 4 4 4 4 4 3 3 3 3 3 3 3 3 3 3 2 2 3 3 2 3 2 2 2 2 2 4 5 5 5 5 4 5 5 5 5 6 4 3 4 4 4 3 3 2 3 4 3 3 3 3 4 4 2 2 2 2 2 2 2 2 2 2 2 2 6 7 6 8 9 9 9 9 1.11696 1.10135 1.11464 1.10982 1.10099 1.09987 1.0946 1.07599 1.09151 1.07712 1.08591 1.07488 1.06386 1.09271 1.0965 1.08134 1.08134 1.1221 1.08279 1.0783 1.07502 1.07618 1.0715 1.06843 1.06267 1.08164 1.22255 1.1942 1.20679 1.22389 1.21933 1.22349 1.21866 1.22167 1.20624 1.20582 1.21812 1.19752 1.25579 1.25389 1.23936 1.27542 1.27244 1.25049 1.25937 1.24947 1.2101 1.19354 1.19679 1.20759 1.20986 1.17886 1.18804 1.21013 1.22356 1.20222 1.19488 1.20899 1.12189 1.14224 1.13458 1.11281 1.13178 1.12469 1.10504 1.13355 1.12067 1.15819 1.09929 1.2005 1.18641 1.15702 1.17161 1.14501 1.1654 1.1358 1.1358 1.1105 1.12843 1.11092 1.12883 1.13553 1.12277 1.11193 1.12045 1.16545 1.16786 1.16224 1.15909 1.16341 1.16009 1.16853 1.1627 1.18617 1.15954 1.16373 1.15538 1.13025 1.12932 1.11109 1.13038 1.12517 1.11434 1.12599 1.11477 Overall AvgFlux Overall Central Error Uniformity Shift Calibration 2 (%) (%) (%) Factor ( sec.) ( ions/(cm s) ) Dead Time 2.494 4.094 4.094 4.094 4.094 -3.844 -2.244 -0.657 -3.87 -3.87 -2.27 -0.683 0.931 2.531 4.119 -3.894 -2.307 -0.707 0.881 0.881 0.881 0.881 0.881 0.955 0.955 0.955 2.543 2.543 2.543 2.543 2.543 2.543 2.543 2.494 2.494 2.494 2.494 2.494 4.094 4.094 4.094 4.094 4.094 4.094 4.142 4.142 -3.844 -2.244 -2.244 -2.244 -2.244 -2.244 -2.244 -2.244 -2.244 -2.244 -2.244 -2.244 -0.657 -0.657 -0.657 -0.657 -0.657 0.955 0.955 0.955 0.955 0.955 0.955 2.543 2.543 2.543 2.543 2.543 2.543 2.543 2.543 4.142 -3.87 -2.27 -0.683 -0.683 -0.683 -0.683 -0.683 0.931 2.531 4.119 -3.894 -2.307 -2.307 -0.707 -0.707 -0.707 0.881 2.494 4.094 -3.844 -2.244 -0.657 0.955 2.543 -3.844 -2.244 -0.657 2.483 2.508 2.508 2.508 2.508 -2.443 -2.418 -2.393 -0.003 -0.003 -0.003 -0.003 -0.003 0.046 0.072 2.384 2.384 2.433 2.433 2.433 2.433 2.433 2.433 -2.393 -2.393 -2.393 -2.343 -2.343 -2.343 -2.343 -2.343 -2.343 -2.343 2.483 2.483 2.483 2.483 2.483 2.508 2.508 2.508 2.508 2.508 2.508 -2.343 -2.343 -2.443 -2.418 -2.418 -2.418 -2.418 -2.418 -2.418 -2.418 -2.418 -2.418 -2.418 -2.418 -2.393 -2.393 -2.393 -2.393 -2.393 -2.393 -2.393 -2.393 -2.393 -2.393 -2.393 -2.343 -2.343 -2.343 -2.343 -2.343 -2.343 -2.343 -2.343 -2.343 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 0.046 0.072 2.384 2.384 2.384 2.433 2.433 2.433 2.433 2.483 2.508 -2.443 -2.418 -2.393 -2.393 -2.343 -2.443 -2.418 -2.393 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 DUT Coordinates X (in) Y (in) Z (cm) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Degree DUT Tilt Angle 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Width 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Height Aperture (inch) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Step 51.338 51.338 51.338 51.338 51.338 51.338 51.338 51.338 51.338 51.338 51.338 51.338 51.338 51.338 51.338 51.338 51.338 51.338 0 0 0 0 0 0 0 0 38.15 38.15 38.15 38.15 38.15 38.15 38.15 38.15 38.15 38.15 38.15 38.15 46.063 46.063 46.063 46.063 46.063 46.063 46.063 46.063 38.15 38.15 38.15 38.15 38.15 38.15 38.15 38.15 38.15 38.15 38.15 38.15 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 38.15 38.15 38.15 38.15 38.15 38.15 38.15 38.15 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 Degree Al Degrader Degrader No. Angle Detector Bias (V) 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 649_457_442_426_559 608_445_422_411_526 608_445_422_411_526 608_445_422_411_526 608_445_422_411_526 608_445_422_411_526 608_445_422_411_526 608_445_422_411_526 608_445_422_411_526 740_482_486_458_631 740_482_486_458_631 740_482_486_458_631 740_482_486_458_631 740_482_486_458_631 740_482_486_458_631 740_482_486_458_631 740_482_486_458_631 740_482_486_458_631 740_482_486_458_631 740_482_486_458_631 740_482_486_458_631 750_495_507_473_668 750_495_507_473_668 750_495_507_473_668 750_495_507_473_668 750_495_507_473_668 750_495_507_473_668 750_495_507_473_668 750_495_507_473_668 740_482_486_458_631 740_482_486_458_631 740_482_486_458_631 740_482_486_458_631 740_482_486_458_631 740_482_486_458_631 740_482_486_458_631 740_482_486_458_631 740_482_486_458_631 740_482_486_458_631 740_482_486_458_631 740_482_486_458_631 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 740_482_486_458_631 740_482_486_458_631 740_482_486_458_631 740_482_486_458_631 740_482_486_458_631 740_482_486_458_631 740_482_486_458_631 740_482_486_458_631 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 Run FileName IR_March_2006.#el IR_March_2006.#em IR_March_2006.#en IR_March_2006.#eo IR_March_2006.#ep IR_March_2006.#eq IR_March_2006.#er IR_March_2006.#es IR_March_2006.#et IR_March_2006.#eu IR_March_2006.#ev IR_March_2006.#ew IR_March_2006.#ex IR_March_2006.#ey IR_March_2006.#ez IR_March_2006.#f0 IR_March_2006.#f1 IR_March_2006.#f2 IR_March_2006.#f3 IR_March_2006.#f4 IR_March_2006.#f5 IR_March_2006.#f6 IR_March_2006.#f7 IR_March_2006.#f8 IR_March_2006.#f9 IR_March_2006.#fa IR_March_2006.#fb IR_March_2006.#fc IR_March_2006.#fd IR_March_2006.#fe IR_March_2006.#ff IR_March_2006.#fg IR_March_2006.#fh IR_March_2006.#fi IR_March_2006.#fj IR_March_2006.#fk IR_March_2006.#fl IR_March_2006.#fm IR_March_2006.#fn IR_March_2006.#fo IR_March_2006.#fp IR_March_2006.#fq IR_March_2006.#fr IR_March_2006.#fs IR_March_2006.#ft IR_March_2006.#fu IR_March_2006.#fv IR_March_2006.#fw IR_March_2006.#fx IR_March_2006.#fy IR_March_2006.#fz IR_March_2006.#g0 IR_March_2006.#g1 IR_March_2006.#g2 IR_March_2006.#g3 IR_March_2006.#g4 IR_March_2006.#g5 IR_March_2006.#g6 IR_March_2006.#g7 IR_March_2006.#g8 IR_March_2006.#g9 IR_March_2006.#ga IR_March_2006.#gb IR_March_2006.#gc IR_March_2006.#gd IR_March_2006.#ge IR_March_2006.#gf IR_March_2006.#gg IR_March_2006.#gh IR_March_2006.#gi IR_March_2006.#gj IR_March_2006.#gk IR_March_2006.#gl IR_March_2006.#gm IR_March_2006.#gn IR_March_2006.#go IR_March_2006.#gp IR_March_2006.#gq IR_March_2006.#gr IR_March_2006.#gs IR_March_2006.#gt IR_March_2006.#gu IR_March_2006.#gv IR_March_2006.#gw IR_March_2006.#gx IR_March_2006.#gy IR_March_2006.#gz IR_March_2006.#h0 IR_March_2006.#h1 IR_March_2006.#h2 IR_March_2006.#h3 IR_March_2006.#h4 IR_March_2006.#h5 IR_March_2006.#h6 IR_March_2006.#h7 IR_March_2006.#h8 IR_March_2006.#h9 IR_March_2006.#ha IR_March_2006.#hb IR_March_2006.#hc IR_March_2006.#hd IR_March_2006.#he IR_March_2006.#hf IR_March_2006.#hg IR_March_2006.#hh Run # 525 526 527 528 529 530 531 532 533 534 535 536 537 538 539 540 541 542 543 544 545 546 547 548 549 550 551 552 553 554 555 556 557 558 559 560 561 562 563 564 565 566 567 568 569 570 571 572 573 574 575 576 577 578 579 580 581 582 584 585 586 587 588 589 590 591 592 593 594 595 596 597 598 599 600 601 602 603 604 605 606 607 608 609 610 611 612 613 614 615 616 617 618 619 620 621 622 623 624 625 626 627 628 629 630 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 Start Date 8:44:17 8:45:06 8:46:19 8:47:23 8:48:01 8:48:35 8:49:28 8:50:13 8:52:04 8:54:35 8:55:47 8:57:40 8:58:16 8:58:56 9:01:52 9:02:43 9:03:28 9:04:00 9:04:52 9:06:45 9:07:16 9:07:53 9:10:30 9:11:07 9:38:51 9:39:57 9:40:32 9:41:21 9:42:23 9:42:59 9:43:42 9:44:33 9:46:52 9:49:09 9:50:15 9:51:29 9:52:17 9:53:33 9:55:34 9:57:04 9:57:50 10:06:25 10:06:59 10:07:42 10:11:01 10:12:28 10:14:52 10:15:51 10:16:45 10:17:25 10:18:52 10:20:03 10:22:07 12:01:52 12:14:28 12:24:38 12:25:23 12:30:52 12:36:14 12:37:27 12:38:09 12:38:47 12:39:43 12:40:28 12:41:04 12:43:44 12:44:22 12:46:31 12:55:23 12:56:36 12:57:17 12:57:58 12:58:48 13:00:25 13:13:47 13:14:35 13:15:17 13:15:57 13:16:47 13:19:36 13:20:21 13:21:10 14:49:16 14:49:56 14:50:34 14:51:44 14:52:59 14:53:33 14:54:06 14:54:36 14:55:10 14:56:21 14:56:56 14:57:32 14:58:10 14:59:18 14:59:55 15:00:26 15:02:09 15:02:43 15:03:40 15:04:20 15:05:26 15:06:06 15:07:56 Start Time 00:00:12_(+_0_days) 00:00:13_(+_0_days) 00:00:15_(+_0_days) 00:00:18_(+_0_days) 00:00:18_(+_0_days) 00:00:12_(+_0_days) 00:00:18_(+_0_days) 00:00:22_(+_0_days) 00:00:23_(+_0_days) 00:00:18_(+_0_days) 00:00:18_(+_0_days) 00:00:22_(+_0_days) 00:00:23_(+_0_days) 00:00:21_(+_0_days) 00:00:22_(+_0_days) 00:00:23_(+_0_days) 00:00:20_(+_0_days) 00:00:20_(+_0_days) 00:00:20_(+_0_days) 00:00:18_(+_0_days) 00:00:17_(+_0_days) 00:00:24_(+_0_days) 00:00:18_(+_0_days) 00:00:19_(+_0_days) 00:00:19_(+_0_days) 00:00:21_(+_0_days) 00:00:23_(+_0_days) 00:00:25_(+_0_days) 00:00:19_(+_0_days) 00:00:19_(+_0_days) 00:00:23_(+_0_days) 00:00:20_(+_0_days) 00:00:21_(+_0_days) 00:00:19_(+_0_days) 00:00:20_(+_0_days) 00:00:08_(+_0_days) 00:00:12_(+_0_days) 00:00:21_(+_0_days) 00:00:13_(+_0_days) 00:00:22_(+_0_days) 00:00:17_(+_0_days) 00:00:19_(+_0_days) 00:00:24_(+_0_days) 00:00:13_(+_0_days) 00:00:21_(+_0_days) 00:00:20_(+_0_days) 00:00:22_(+_0_days) 00:00:22_(+_0_days) 00:00:20_(+_0_days) 00:00:20_(+_0_days) 00:00:22_(+_0_days) 00:00:26_(+_0_days) 00:00:26_(+_0_days) 00:00:18_(+_0_days) 00:00:20_(+_0_days) 00:00:17_(+_0_days) 00:00:19_(+_0_days) 00:00:23_(+_0_days) 00:00:18_(+_0_days) 00:00:18_(+_0_days) 00:00:18_(+_0_days) 00:00:18_(+_0_days) 00:00:19_(+_0_days) 00:00:18_(+_0_days) 00:00:18_(+_0_days) 00:00:20_(+_0_days) 00:00:11_(+_0_days) 00:00:19_(+_0_days) 00:00:24_(+_0_days) 00:00:21_(+_0_days) 00:00:22_(+_0_days) 00:00:20_(+_0_days) 00:00:20_(+_0_days) 00:00:18_(+_0_days) 00:00:20_(+_0_days) 00:00:22_(+_0_days) 00:00:21_(+_0_days) 00:00:20_(+_0_days) 00:00:11_(+_0_days) 00:00:21_(+_0_days) 00:00:33_(+_0_days) 00:00:21_(+_0_days) 00:00:22_(+_0_days) 00:00:19_(+_0_days) 00:00:46_(+_0_days) 00:00:24_(+_0_days) 00:00:25_(+_0_days) 00:00:20_(+_0_days) 00:00:19_(+_0_days) 00:00:21_(+_0_days) 00:00:24_(+_0_days) 00:00:22_(+_0_days) 00:00:23_(+_0_days) 00:00:26_(+_0_days) 00:00:10_(+_0_days) 00:00:23_(+_0_days) 00:00:20_(+_0_days) 00:00:08_(+_0_days) 00:00:22_(+_0_days) 00:00:21_(+_0_days) 00:00:21_(+_0_days) 00:00:22_(+_0_days) 00:00:20_(+_0_days) 00:00:21_(+_0_days) 00:00:09_(+_0_days) Run Duration 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Upset Events 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe Selected Beam 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 1.959 2.543 2.543 2.543 2.543 2.543 2.543 2.882 2.882 2.882 2.882 2.882 2.882 2.882 2.882 2.434 2.434 2.434 2.434 2.434 2.434 2.434 2.434 2.434 2.434 2.434 2.434 2.434 2.434 2.434 2.434 2.434 2.434 2.434 2.434 2.434 2.434 2.434 ( µm ) Al Thk 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) # of Layers ( Filename ) 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 5.4 5.4 5.4 5.4 5.4 5.4 4.3 4.3 4.3 4.3 4.3 4.3 4.3 4.3 5.7 5.7 5.7 5.7 5.7 5.7 5.7 5.7 5.7 5.7 5.7 5.7 5.7 5.7 5.7 5.7 5.7 5.7 5.7 5.7 5.7 5.7 5.7 (MeV/amu) 924 924 924 924 924 924 924 924 924 924 924 924 924 924 924 924 924 924 924 924 924 924 924 924 924 924 924 924 924 924 924 924 924 924 924 924 924 924 924 924 924 924 924 924 924 924 924 924 924 924 924 924 924 924 924 924 924 924 924 924 924 924 924 924 924 924 924 924 693 693 693 693 693 693 553 553 553 553 553 553 553 553 737 737 737 737 737 737 737 737 737 737 737 737 737 737 737 737 737 737 737 737 737 737 737 (MeV) Beam Energy silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 60.5 60.5 60.5 60.5 60.5 60.5 62 62 62 62 62 62 62 62 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 56.4 56.4 56.4 56.4 56.4 56.4 46.5 46.5 46.5 46.5 46.5 46.5 46.5 46.5 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 60.5 60.5 60.5 60.5 60.5 60.5 62 62 62 62 62 62 62 62 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 73.2 56.4 56.4 56.4 56.4 56.4 56.4 46.5 46.5 46.5 46.5 46.5 46.5 46.5 46.5 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 22 In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current 9.40E+04 5.89E+04 1.90E+05 3.08E+05 2.98E+05 1.55E+05 3.07E+05 2.92E+05 2.89E+05 3.07E+05 2.95E+05 2.99E+05 3.08E+05 3.06E+05 3.08E+05 3.04E+05 2.93E+05 3.00E+05 2.23E+05 3.02E+05 2.96E+05 2.31E+05 2.98E+05 2.94E+05 3.07E+05 3.05E+05 3.08E+05 3.05E+05 3.02E+05 2.92E+05 3.05E+05 2.96E+05 2.91E+05 2.92E+05 3.04E+05 7.52E+04 1.12E+05 2.94E+05 1.22E+05 2.91E+05 2.30E+05 2.90E+05 3.09E+05 1.28E+05 3.06E+05 2.99E+05 2.91E+05 2.94E+05 2.92E+05 2.91E+05 2.98E+05 2.96E+05 2.97E+05 3.03E+05 3.00E+05 2.98E+05 2.99E+05 3.09E+05 2.92E+05 3.01E+05 2.94E+05 2.98E+05 3.02E+05 3.10E+05 3.01E+05 2.90E+05 1.21E+05 2.53E+05 3.02E+05 3.08E+05 2.93E+05 3.09E+05 3.08E+05 2.70E+05 2.92E+05 3.06E+05 2.99E+05 2.96E+05 1.21E+05 3.07E+05 3.09E+05 2.96E+05 2.98E+05 2.94E+05 2.99E+05 3.06E+05 3.07E+05 2.94E+05 2.92E+05 3.02E+05 3.00E+05 3.07E+05 3.01E+05 3.05E+05 7.06E+04 2.92E+05 2.95E+05 3.85E+04 3.01E+05 3.02E+05 2.99E+05 2.92E+05 3.08E+05 2.97E+05 5.59E+04 Nominal Nominal Effective Effective Effective Target LET Range LET Range DUT Position Fluence 2 (MeV.cm /mg) Material (MeV.cm2/mg) Location Name ( ions/cm2 ) ( µm ) ( µm ) 8.71E+01 5.45E+01 1.76E+02 2.85E+02 2.76E+02 1.43E+02 2.84E+02 2.70E+02 2.68E+02 2.84E+02 2.73E+02 2.77E+02 2.85E+02 2.83E+02 2.85E+02 2.82E+02 2.71E+02 2.77E+02 2.06E+02 2.80E+02 2.74E+02 2.14E+02 2.76E+02 2.72E+02 2.84E+02 2.82E+02 2.86E+02 2.82E+02 2.80E+02 2.70E+02 2.82E+02 2.74E+02 2.70E+02 2.70E+02 2.82E+02 6.96E+01 1.04E+02 2.72E+02 1.13E+02 2.69E+02 2.13E+02 2.69E+02 2.86E+02 1.19E+02 2.83E+02 2.77E+02 2.69E+02 2.73E+02 2.71E+02 2.69E+02 2.76E+02 2.74E+02 2.75E+02 2.81E+02 2.78E+02 2.76E+02 2.77E+02 2.86E+02 2.71E+02 2.79E+02 2.73E+02 2.76E+02 2.80E+02 2.87E+02 2.79E+02 2.69E+02 1.12E+02 2.34E+02 2.92E+02 2.99E+02 2.84E+02 2.99E+02 2.99E+02 2.62E+02 2.90E+02 3.04E+02 2.97E+02 2.94E+02 1.20E+02 3.05E+02 3.07E+02 2.94E+02 2.87E+02 2.83E+02 2.87E+02 2.94E+02 2.95E+02 2.83E+02 2.81E+02 2.90E+02 2.88E+02 2.95E+02 2.89E+02 2.93E+02 6.78E+01 2.80E+02 2.84E+02 3.70E+01 2.89E+02 2.90E+02 2.88E+02 2.80E+02 2.96E+02 2.85E+02 5.38E+01 ( rad ) Dose International Rectifier Corp. SEE Test Report March 2006 – T.A.M.U. 4.48333 3.08333 8.9 13.9833 13.8167 7.18333 13.9333 13.3167 13.6 13.5167 12.75 13.3667 13.8167 13.4167 13.8833 13.6833 13.1333 13.2167 10.0167 14.1 13.5833 11 14.25 14.4167 14.8333 14.7333 14.9 15.0833 15.1167 14.65 15.5333 14.9167 14.7 14.85 16.2167 4.23333 6.06667 15.6833 6.86667 15.2833 12.7 15.3333 17.0833 7.11667 16.5667 16.3167 15.9167 16.3333 15.3667 15.05 15.6833 15.8667 16.0667 14 14.0833 14.2167 14.5667 14.8667 14.2167 14.3833 14.2 13.9833 14.1 14.6167 14.2167 14.1833 6.13333 12.7833 16.05 15.9667 15.7667 14.9167 16.3667 14.2667 16.5833 16.5 16.4333 15.8333 6.75 17.2167 16.9167 16.3167 14.4333 14.6 15.2833 15.05 15.9833 15.3667 14.65 15.7833 17.2667 16.5167 18.7333 19.6 5.06667 18.9333 16.2667 2.51667 15.7667 16.3667 16.5 15.8 16.6167 15.6833 3.31667 ( sec.) Live Time 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2.10E+04 1.91E+04 2.13E+04 2.20E+04 2.15E+04 2.15E+04 2.20E+04 2.19E+04 2.13E+04 2.27E+04 2.31E+04 2.24E+04 2.23E+04 2.28E+04 2.22E+04 2.22E+04 2.23E+04 2.27E+04 2.23E+04 2.14E+04 2.18E+04 2.10E+04 2.09E+04 2.04E+04 2.07E+04 2.07E+04 2.07E+04 2.02E+04 2.00E+04 1.99E+04 1.96E+04 1.99E+04 1.98E+04 1.96E+04 1.88E+04 1.78E+04 1.85E+04 1.88E+04 1.78E+04 1.90E+04 1.81E+04 1.89E+04 1.81E+04 1.80E+04 1.84E+04 1.83E+04 1.83E+04 1.80E+04 1.90E+04 1.93E+04 1.90E+04 1.87E+04 1.85E+04 2.17E+04 2.13E+04 2.10E+04 2.05E+04 2.08E+04 2.06E+04 2.09E+04 2.07E+04 2.13E+04 2.14E+04 2.12E+04 2.12E+04 2.05E+04 1.97E+04 1.98E+04 1.88E+04 1.93E+04 1.86E+04 2.07E+04 1.88E+04 1.89E+04 1.76E+04 1.85E+04 1.82E+04 1.87E+04 1.79E+04 1.79E+04 1.83E+04 1.81E+04 2.07E+04 2.01E+04 1.96E+04 2.03E+04 1.92E+04 1.92E+04 1.99E+04 1.91E+04 1.74E+04 1.86E+04 1.61E+04 1.56E+04 1.39E+04 1.54E+04 1.81E+04 1.53E+04 1.91E+04 1.84E+04 1.81E+04 1.85E+04 1.86E+04 1.89E+04 1.69E+04 Average Flux 1 1.3 0.73 0.57 0.58 0.8 0.57 0.59 0.59 0.57 0.58 0.58 0.57 0.57 0.57 0.57 0.58 0.58 0.67 0.58 0.58 0.66 0.58 0.58 0.57 0.57 0.57 0.57 0.58 0.59 0.57 0.58 0.59 0.59 0.57 1.2 0.94 0.58 0.91 0.59 0.66 0.59 0.57 0.88 0.57 0.58 0.59 0.58 0.58 0.59 0.58 0.58 0.58 0.57 0.58 0.58 0.58 0.57 0.58 0.58 0.58 0.58 0.58 0.57 0.58 0.59 0.91 0.63 0.58 0.57 0.58 0.57 0.57 0.61 0.59 0.57 0.58 0.58 0.91 0.57 0.57 0.58 0.58 0.58 0.58 0.57 0.57 0.58 0.59 0.58 0.58 0.57 0.58 0.57 1.2 0.59 0.58 1.6 0.58 0.58 0.58 0.59 0.57 0.58 1.3 90 91 90 89 89 90 89 89 89 89 90 89 89 89 89 89 89 90 90 89 89 90 89 89 89 89 89 89 88 88 88 88 89 88 88 89 89 89 89 89 89 89 89 90 89 89 88 89 89 89 89 89 88 90 90 90 90 90 90 90 90 90 91 90 90 91 91 90 89 89 89 91 91 91 93 93 93 93 93 93 92 93 87 87 87 88 88 88 89 88 88 88 88 88 91 89 89 87 88 88 88 89 89 90 89 7 7 7 7 7 7 7 7 7 7 7 7 7 7 8 7 7 7 7 8 7 7 7 8 8 8 7 8 8 8 8 8 7 8 8 7 7 7 7 7 7 7 8 7 7 8 8 8 8 7 8 7 8 4 3 4 4 3 4 3 4 3 3 3 3 3 3 3 3 3 4 7 7 6 4 4 3 4 4 4 4 4 9 9 9 9 9 9 8 9 9 9 9 9 8 8 8 9 9 9 9 8 8 8 8 1.12399 1.10872 1.0937 1.10209 1.09971 1.10841 1.12663 1.11604 1.13178 1.10567 1.12756 1.11275 1.10055 1.11854 1.09421 1.11052 1.1096 1.12456 1.11774 1.09188 1.12001 1.10257 1.11692 1.10993 1.12428 1.11921 1.10725 1.09365 1.10961 1.10801 1.10699 1.10593 1.11786 1.11701 1.09192 1.12986 1.12986 1.10652 1.10491 1.11418 1.10584 1.10819 1.09033 1.09826 1.11308 1.09983 1.12247 1.09467 1.06812 1.10808 1.11126 1.11026 1.11155 1.12179 1.11355 1.12955 1.12768 1.14047 1.11231 1.12359 1.113 1.11441 1.12898 1.13677 1.12874 1.12149 1.13297 1.12371 1.15741 1.18004 1.16146 1.20433 1.07868 1.10461 1.10098 1.17989 1.17365 1.18177 1.1862 1.1737 1.16588 1.1915 1.09617 1.05992 1.06167 1.06681 1.06089 1.06903 1.07442 1.09077 1.10866 1.06573 1.07319 1.05956 1.04703 1.04703 1.05818 1.06428 1.08292 1.06019 1.06019 1.07323 1.06198 1.08439 1.08439 Overall AvgFlux Overall Central Error Uniformity Shift Calibration 2 (%) (%) (%) Factor ( sec.) ( ions/(cm s) ) Dead Time -3.844 -2.244 -0.657 0.955 0.955 0.955 2.543 2.543 4.142 4.142 4.142 4.142 4.142 4.142 -3.87 -3.87 -3.87 -3.87 -3.87 -2.27 -2.27 -2.27 -0.683 -0.683 0.931 0.931 0.931 0.931 0.931 0.931 0.931 0.931 0.931 0.931 0.931 0.931 2.531 4.119 -3.894 -2.307 -2.307 -0.707 -0.707 -0.707 0.881 0.881 0.881 2.494 2.494 2.494 4.094 4.094 4.094 -3.844 -3.844 -2.244 -2.244 4.142 -2.27 -2.27 -2.27 -2.27 -2.27 -2.27 -2.27 -3.87 -3.87 -2.27 -0.683 -0.683 -0.683 -0.683 -0.683 -0.683 0.931 0.931 0.931 0.931 0.931 4.119 4.119 4.119 -3.844 -3.844 -3.844 -3.844 -2.244 -2.244 -2.244 -2.244 -2.244 -2.244 -2.244 -2.244 -2.244 -0.657 -0.657 -0.657 0.955 0.955 2.543 2.543 4.142 4.142 -3.87 -2.443 -2.418 -2.393 -2.393 -2.393 -2.393 -2.343 -2.343 -2.343 -2.343 -2.343 -2.343 -2.343 -2.343 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 0.046 0.072 2.384 2.384 2.384 2.433 2.433 2.433 2.433 2.433 2.433 2.483 2.483 2.483 2.508 2.508 2.508 -2.443 -2.443 -2.418 -2.418 -2.343 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 0.072 0.072 0.072 -2.443 -2.443 -2.443 -2.443 -2.418 -2.418 -2.418 -2.418 -2.418 -2.418 -2.418 -2.418 -2.418 -2.393 -2.393 -2.393 -2.393 -2.393 -2.343 -2.343 -2.343 -2.343 -0.003 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 DUT Coordinates X (in) Y (in) Z (cm) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Degree DUT Tilt Angle 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Width 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Height Aperture (inch) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Step 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 59.3 38.15 38.15 38.15 38.15 38.15 38.15 46.063 46.063 46.063 46.063 46.063 46.063 46.063 46.063 34.737 34.737 34.737 34.737 34.737 34.737 34.737 34.737 34.737 34.737 34.737 34.737 34.737 34.737 34.737 34.737 34.737 34.737 34.737 34.737 34.737 34.737 34.737 Degree Al Degrader Degrader No. Angle Detector Bias (V) 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 679_466_457_437_583 740_482_486_458_631 740_482_486_458_631 740_482_486_458_631 740_482_486_458_631 740_482_486_458_631 740_482_486_458_631 750_495_507_473_668 750_495_507_473_668 750_495_507_473_668 750_495_507_473_668 750_495_507_473_668 750_495_507_473_668 750_495_507_473_668 750_495_507_473_668 727_479_480_453_621 727_479_480_453_621 727_479_480_453_621 727_479_480_453_621 727_479_480_453_621 727_479_480_453_621 727_479_480_453_621 727_479_480_453_621 727_479_480_453_621 727_479_480_453_621 727_479_480_453_621 727_479_480_453_621 727_479_480_453_621 727_479_480_453_621 727_479_480_453_621 727_479_480_453_621 727_479_480_453_621 727_479_480_453_621 727_479_480_453_621 727_479_480_453_621 727_479_480_453_621 727_479_480_453_621 727_479_480_453_621 Run FileName IR_March_2006.#hi IR_March_2006.#hj IR_March_2006.#hk IR_March_2006.#hl IR_March_2006.#hm IR_March_2006.#hn IR_March_2006.#ho IR_March_2006.#hp IR_March_2006.#hq IR_March_2006.#hr IR_March_2006.#hs IR_March_2006.#ht IR_March_2006.#hu IR_March_2006.#hv IR_March_2006.#hw IR_March_2006.#hx IR_March_2006.#hy IR_March_2006.#hz IR_March_2006.#i0 IR_March_2006.#i1 IR_March_2006.#i2 IR_March_2006.#i3 IR_March_2006.#i4 IR_March_2006.#i5 IR_March_2006.#i6 IR_March_2006.#i7 IR_March_2006.#i8 IR_March_2006.#i9 IR_March_2006.#ia IR_March_2006.#ib IR_March_2006.#ic IR_March_2006.#id IR_March_2006.#ie IR_March_2006.#if IR_March_2006.#ig IR_March_2006.#ih IR_March_2006.#ii IR_March_2006.#ij IR_March_2006.#ik IR_March_2006.#il IR_March_2006.#im IR_March_2006.#in IR_March_2006.#io IR_March_2006.#ip IR_March_2006.#iq IR_March_2006.#ir IR_March_2006.#is IR_March_2006.#it IR_March_2006.#iu IR_March_2006.#iv IR_March_2006.#iw IR_March_2006.#ix IR_March_2006.#iy IR_March_2006.#iz IR_March_2006.#j0 IR_March_2006.#j1 IR_March_2006.#j2 IR_March_2006.#j3 IR_March_2006.#j4 IR_March_2006.#j5 IR_March_2006.#j6 IR_March_2006.#j7 IR_March_2006.#j8 IR_March_2006.#j9 IR_March_2006.#ja IR_March_2006.#jb IR_March_2006.#jc IR_March_2006.#jd IR_March_2006.#je IR_March_2006.#jf IR_March_2006.#jg IR_March_2006.#jh IR_March_2006.#ji IR_March_2006.#jj IR_March_2006.#jk IR_March_2006.#jl IR_March_2006.#jm IR_March_2006.#jn IR_March_2006.#jo IR_March_2006.#jp IR_March_2006.#jq IR_March_2006.#jr IR_March_2006.#js IR_March_2006.#jt IR_March_2006.#ju IR_March_2006.#jv IR_March_2006.#jw IR_March_2006.#jx IR_March_2006.#jy IR_March_2006.#jz IR_March_2006.#k0 IR_March_2006.#k1 IR_March_2006.#k2 IR_March_2006.#k3 IR_March_2006.#k4 IR_March_2006.#k5 IR_March_2006.#k6 IR_March_2006.#k7 IR_March_2006.#k8 IR_March_2006.#k9 IR_March_2006.#ka IR_March_2006.#kb IR_March_2006.#kc IR_March_2006.#kd IR_March_2006.#ke Run # 631 632 633 634 635 636 637 638 639 640 641 642 643 644 645 646 647 648 649 650 651 652 653 654 655 656 657 658 659 660 661 662 663 664 665 666 667 668 669 670 671 672 673 674 675 676 677 678 679 680 681 682 683 684 685 686 687 688 689 690 691 692 693 694 695 696 697 698 699 700 701 702 703 704 705 706 707 708 709 710 711 712 713 714 715 716 717 718 719 720 721 722 723 724 725 726 727 728 729 730 731 732 733 734 735 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 Start Date 15:08:49 15:09:49 15:14:03 15:14:49 15:15:21 15:15:58 15:16:31 15:17:31 15:19:54 15:21:38 15:24:46 15:26:48 15:29:32 15:30:14 15:31:33 15:32:12 15:34:52 15:35:28 15:36:25 15:37:19 15:38:26 15:39:01 15:39:52 15:40:26 15:41:00 16:14:54 16:15:41 16:16:22 16:21:14 16:21:48 16:22:14 16:23:22 16:23:52 16:24:45 16:25:15 16:25:47 16:26:31 16:28:41 16:29:45 16:30:20 16:31:10 16:31:41 16:32:16 16:33:07 16:33:37 16:34:09 16:35:23 18:42:51 18:43:34 18:44:23 18:45:13 18:46:00 18:47:13 18:48:03 18:48:56 18:50:09 18:51:42 18:54:18 18:57:13 18:58:14 18:59:16 19:01:09 19:02:07 19:02:55 19:03:47 19:04:49 19:05:32 19:07:24 19:08:13 19:09:08 19:10:09 19:11:01 19:11:51 19:14:38 19:17:15 19:18:39 19:19:47 19:22:06 19:23:18 19:25:52 19:26:44 19:27:50 19:29:17 19:36:09 19:37:18 19:39:47 19:41:36 20:09:27 20:10:06 20:11:34 20:12:21 20:13:41 20:14:40 20:16:00 20:17:51 20:19:36 20:20:35 20:22:41 20:23:42 20:24:33 20:27:18 20:28:14 20:29:07 20:29:51 20:30:37 Start Time 00:00:21_(+_0_days) 00:00:28_(+_0_days) 00:00:20_(+_0_days) 00:00:20_(+_0_days) 00:00:20_(+_0_days) 00:00:19_(+_0_days) 00:00:20_(+_0_days) 00:00:24_(+_0_days) 00:00:23_(+_0_days) 00:00:21_(+_0_days) 00:00:17_(+_0_days) 00:00:19_(+_0_days) 00:00:22_(+_0_days) 00:00:18_(+_0_days) 00:00:17_(+_0_days) 00:00:23_(+_0_days) 00:00:19_(+_0_days) 00:00:18_(+_0_days) 00:00:18_(+_0_days) 00:00:10_(+_0_days) 00:00:15_(+_0_days) 00:00:12_(+_0_days) 00:00:22_(+_0_days) 00:00:19_(+_0_days) 00:00:16_(+_0_days) 00:00:15_(+_0_days) 00:00:14_(+_0_days) 00:00:14_(+_0_days) 00:00:22_(+_0_days) 00:00:13_(+_0_days) 00:00:14_(+_0_days) 00:00:13_(+_0_days) 00:00:18_(+_0_days) 00:00:13_(+_0_days) 00:00:14_(+_0_days) 00:00:13_(+_0_days) 00:00:24_(+_0_days) 00:00:15_(+_0_days) 00:00:24_(+_0_days) 00:00:13_(+_0_days) 00:00:13_(+_0_days) 00:00:14_(+_0_days) 00:00:14_(+_0_days) 00:00:17_(+_0_days) 00:00:16_(+_0_days) 00:00:14_(+_0_days) 00:00:13_(+_0_days) 00:00:25_(+_0_days) 00:00:26_(+_0_days) 00:00:33_(+_0_days) 00:00:34_(+_0_days) 00:00:42_(+_0_days) 00:00:37_(+_0_days) 00:00:37_(+_0_days) 00:00:37_(+_0_days) 00:00:49_(+_0_days) 00:00:44_(+_0_days) 00:01:00_(+_0_days) 00:00:45_(+_0_days) 00:00:47_(+_0_days) 00:00:16_(+_0_days) 00:00:44_(+_0_days) 00:00:33_(+_0_days) 00:00:36_(+_0_days) 00:00:35_(+_0_days) 00:00:30_(+_0_days) 00:00:32_(+_0_days) 00:00:35_(+_0_days) 00:00:36_(+_0_days) 00:00:40_(+_0_days) 00:00:36_(+_0_days) 00:00:37_(+_0_days) 00:00:23_(+_0_days) 00:00:34_(+_0_days) 00:00:28_(+_0_days) 00:00:35_(+_0_days) 00:00:38_(+_0_days) 00:00:52_(+_0_days) 00:00:38_(+_0_days) 00:00:38_(+_0_days) 00:00:33_(+_0_days) 00:00:39_(+_0_days) 00:00:32_(+_0_days) 00:00:22_(+_0_days) 00:00:21_(+_0_days) 00:00:08_(+_0_days) 00:00:19_(+_0_days) 00:00:25_(+_0_days) 00:00:28_(+_0_days) 00:00:33_(+_0_days) 00:00:28_(+_0_days) 00:00:43_(+_0_days) 00:00:50_(+_0_days) 00:00:48_(+_0_days) 00:00:45_(+_0_days) 00:00:42_(+_0_days) 00:00:45_(+_0_days) 00:00:53_(+_0_days) 00:00:38_(+_0_days) 00:00:34_(+_0_days) 00:00:34_(+_0_days) 00:00:34_(+_0_days) 00:00:32_(+_0_days) 00:00:31_(+_0_days) 00:00:32_(+_0_days) Run Duration 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Upset Events 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Xe 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au Selected Beam 2.434 2.434 2.434 2.434 2.434 2.434 2.434 2.434 2.434 2.434 2.434 2.434 2.434 2.434 2.434 2.434 2.434 2.434 2.434 2.434 2.434 2.434 2.434 2.434 2.434 2.434 2.434 2.434 2.434 2.434 2.434 2.434 2.434 2.434 2.434 2.434 2.434 2.434 2.434 2.434 2.434 2.434 2.434 2.434 2.434 2.434 2.434 1 1 1 1 1 1 1 1 1 1 1.525 1.525 1.525 1.525 2.405 2.405 2.405 2.405 2.405 2.405 1.525 1.525 1.525 1.525 1.525 1.525 1.525 1.525 1.525 1.525 1.525 1.525 1.525 1.525 1.525 1.525 1.525 1.525 1.525 1.525 1.187 1.187 1.187 1.187 1.187 1.187 1.187 1.187 1.187 1.187 1.187 1.187 1.187 1.187 1.187 1.187 1.187 1.187 ( µm ) Al Thk 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) # of Layers ( Filename ) 5.7 5.7 5.7 5.7 5.7 5.7 5.7 5.7 5.7 5.7 5.7 5.7 5.7 5.7 5.7 5.7 5.7 5.7 5.7 5.7 5.7 5.7 5.7 5.7 5.7 5.7 5.7 5.7 5.7 5.7 5.7 5.7 5.7 5.7 5.7 5.7 5.7 5.7 5.7 5.7 5.7 5.7 5.7 5.7 5.7 5.7 5.7 9.5 9.5 9.5 9.5 9.5 9.5 9.5 9.5 9.5 9.5 7.9 7.9 7.9 7.9 5.2 5.2 5.2 5.2 5.2 5.2 7.9 7.9 7.9 7.9 7.9 7.9 7.9 7.9 7.9 7.9 7.9 7.9 7.9 7.9 7.9 7.9 7.9 7.9 7.9 7.9 8.9 8.9 8.9 8.9 8.9 8.9 8.9 8.9 8.9 8.9 8.9 8.9 8.9 8.9 8.9 8.9 8.9 8.9 (MeV/amu) 737 737 737 737 737 737 737 737 737 737 737 737 737 737 737 737 737 737 737 737 737 737 737 737 737 737 737 737 737 737 737 737 737 737 737 737 737 737 737 737 737 737 737 737 737 737 737 1863 1863 1863 1863 1863 1863 1863 1863 1863 1863 1555 1555 1555 1555 1017 1017 1017 1017 1017 1017 1555 1555 1555 1555 1555 1555 1555 1555 1555 1555 1555 1555 1555 1555 1555 1555 1555 1555 1555 1555 1755 1755 1755 1755 1755 1755 1755 1755 1755 1755 1755 1755 1755 1755 1755 1755 1755 1755 (MeV) Beam Energy silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 87.5 87.5 87.5 87.5 87.5 87.5 87.5 87.5 87.5 87.5 89.5 89.5 89.5 89.5 93.4 93.4 93.4 93.4 93.4 93.4 89.5 89.5 89.5 89.5 89.5 89.5 89.5 89.5 89.5 89.5 89.5 89.5 89.5 89.5 89.5 89.5 89.5 89.5 89.5 89.5 88.2 88.2 88.2 88.2 88.2 88.2 88.2 88.2 88.2 88.2 88.2 88.2 88.2 88.2 88.2 88.2 88.2 88.2 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 99 99 99 99 99 99 99 99 99 99 84 84 84 84 58.6 58.6 58.6 58.6 58.6 58.6 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 93.7 93.7 93.7 93.7 93.7 93.7 93.7 93.7 93.7 93.7 93.7 93.7 93.7 93.7 93.7 93.7 93.7 93.7 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 87.5 87.5 87.5 87.5 87.5 87.5 87.5 87.5 87.5 87.5 89.5 89.5 89.5 89.5 93.4 93.4 93.4 93.4 93.4 93.4 89.5 89.5 89.5 89.5 89.5 89.5 89.5 89.5 89.5 89.5 89.5 89.5 89.5 89.5 89.5 89.5 89.5 89.5 89.5 89.5 88.2 88.2 88.2 88.2 88.2 88.2 88.2 88.2 88.2 88.2 88.2 88.2 88.2 88.2 88.2 88.2 88.2 88.2 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 59.6 99 99 99 99 99 99 99 99 99 99 84 84 84 84 58.6 58.6 58.6 58.6 58.6 58.6 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 84 93.7 93.7 93.7 93.7 93.7 93.7 93.7 93.7 93.7 93.7 93.7 93.7 93.7 93.7 93.7 93.7 93.7 93.7 23 In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current 2.94E+05 3.02E+05 3.02E+05 3.10E+05 3.04E+05 3.02E+05 3.04E+05 3.05E+05 2.95E+05 3.02E+05 3.02E+05 2.90E+05 2.91E+05 2.93E+05 2.91E+05 3.10E+05 3.01E+05 2.92E+05 2.37E+05 1.21E+05 3.05E+05 8.26E+04 3.14E+05 2.96E+05 3.02E+05 3.15E+05 2.98E+05 3.04E+05 3.01E+05 2.96E+05 3.18E+05 2.85E+05 3.08E+05 3.09E+05 2.91E+05 3.08E+05 3.14E+05 3.01E+05 2.93E+05 3.01E+05 2.89E+05 2.85E+05 3.04E+05 2.85E+05 3.03E+05 3.03E+05 2.89E+05 3.02E+05 2.96E+05 2.97E+05 3.05E+05 2.98E+05 3.01E+05 2.96E+05 3.05E+05 2.99E+05 2.98E+05 3.00E+05 2.98E+05 3.00E+05 7.03E+04 3.05E+05 2.97E+05 3.04E+05 2.98E+05 2.98E+05 3.01E+05 2.99E+05 3.00E+05 3.04E+05 2.97E+05 3.04E+05 2.05E+05 2.95E+05 3.01E+05 3.04E+05 3.03E+05 2.99E+05 2.98E+05 3.02E+05 2.97E+05 3.01E+05 2.97E+05 3.02E+05 3.00E+05 6.05E+04 2.90E+05 3.01E+05 2.64E+05 3.05E+05 2.56E+05 3.02E+05 2.99E+05 3.00E+05 3.00E+05 3.00E+05 3.01E+05 3.03E+05 3.01E+05 2.98E+05 2.95E+05 2.98E+05 2.97E+05 2.98E+05 2.97E+05 Nominal Nominal Effective Effective Effective Target LET Range LET Range DUT Position Fluence 2 (MeV.cm /mg) Material (MeV.cm2/mg) Location Name ( ions/cm2 ) ( µm ) ( µm ) 2.83E+02 2.90E+02 2.90E+02 2.98E+02 2.92E+02 2.91E+02 2.93E+02 2.93E+02 2.84E+02 2.90E+02 2.91E+02 2.79E+02 2.80E+02 2.82E+02 2.79E+02 2.98E+02 2.89E+02 2.81E+02 2.28E+02 1.16E+02 2.93E+02 7.94E+01 3.02E+02 2.85E+02 2.91E+02 3.03E+02 2.86E+02 2.92E+02 2.89E+02 2.84E+02 3.06E+02 2.74E+02 2.96E+02 2.97E+02 2.80E+02 2.96E+02 3.02E+02 2.89E+02 2.82E+02 2.90E+02 2.78E+02 2.74E+02 2.93E+02 2.74E+02 2.91E+02 2.91E+02 2.78E+02 4.23E+02 4.15E+02 4.17E+02 4.27E+02 4.18E+02 4.22E+02 4.16E+02 4.27E+02 4.18E+02 4.17E+02 4.30E+02 4.28E+02 4.31E+02 1.01E+02 4.56E+02 4.45E+02 4.55E+02 4.45E+02 4.46E+02 4.50E+02 4.28E+02 4.31E+02 4.36E+02 4.25E+02 4.36E+02 2.93E+02 4.24E+02 4.32E+02 4.36E+02 4.34E+02 4.29E+02 4.27E+02 4.33E+02 4.25E+02 4.31E+02 4.25E+02 4.33E+02 4.30E+02 8.68E+01 4.16E+02 4.25E+02 3.73E+02 4.31E+02 3.61E+02 4.27E+02 4.23E+02 4.24E+02 4.24E+02 4.24E+02 4.26E+02 4.28E+02 4.26E+02 4.21E+02 4.17E+02 4.21E+02 4.20E+02 4.21E+02 4.19E+02 ( rad ) Dose International Rectifier Corp. SEE Test Report March 2006 – T.A.M.U. 15.9167 16.6167 15.6333 15.6167 14.8 14.5 15 14.9 13.95 13.7833 13.8333 12.5333 12.05 12.25 12.2333 12.7833 11.2833 10.7333 8.55 4.75 10.8833 3.16667 11.2167 10 9.68333 9.25 8.71667 8.9 8.5 8.56667 8.73333 8.23333 8.86667 8.65 8.76667 8.48333 9.03333 8.25 8.15 8.43333 8.26667 8.28333 8.85 8.43333 8.93333 9.16667 8.8 20 21.6 28.8167 29.4333 28 31.35 32.2333 32 44.4333 38.5833 41.5 40.2333 42.2833 10.6833 40.4667 28.8667 32.25 30.6167 25.4333 27 30.85 32.35 35.3167 32.15 30.25 17.4833 24.35 23.3167 26.1333 32.9333 47.25 34.8667 34.1667 28.6 28.0333 24.7167 18.0167 16.1833 3.95 14.5 20.3 22.0833 28.65 23.55 35.9167 45.75 42.5 40.95 37.15 37.3667 36.75 32.2833 30.1833 27.8167 28.3 27.1667 27.2667 25.9333 ( sec.) Live Time 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1.85E+04 1.82E+04 1.93E+04 1.98E+04 2.05E+04 2.08E+04 2.03E+04 2.05E+04 2.11E+04 2.19E+04 2.19E+04 2.31E+04 2.41E+04 2.39E+04 2.38E+04 2.42E+04 2.66E+04 2.72E+04 2.77E+04 2.54E+04 2.80E+04 2.61E+04 2.80E+04 2.96E+04 3.12E+04 3.41E+04 3.42E+04 3.42E+04 3.54E+04 3.45E+04 3.65E+04 3.46E+04 3.47E+04 3.57E+04 3.32E+04 3.63E+04 3.47E+04 3.64E+04 3.60E+04 3.57E+04 3.50E+04 3.44E+04 3.44E+04 3.39E+04 3.39E+04 3.30E+04 3.28E+04 1.51E+04 1.37E+04 1.03E+04 1.04E+04 1.07E+04 9.61E+03 9.19E+03 9.52E+03 6.72E+03 7.72E+03 7.23E+03 7.42E+03 7.10E+03 6.58E+03 7.52E+03 1.03E+04 9.43E+03 9.72E+03 1.17E+04 1.12E+04 9.68E+03 9.28E+03 8.61E+03 9.23E+03 1.01E+04 1.17E+04 1.21E+04 1.29E+04 1.16E+04 9.19E+03 6.33E+03 8.55E+03 8.84E+03 1.04E+04 1.07E+04 1.20E+04 1.68E+04 1.85E+04 1.53E+04 2.00E+04 1.48E+04 1.19E+04 1.06E+04 1.09E+04 8.42E+03 6.54E+03 7.06E+03 7.33E+03 8.07E+03 8.06E+03 8.24E+03 9.33E+03 9.88E+03 1.06E+04 1.05E+04 1.09E+04 1.09E+04 1.14E+04 Average Flux 0.58 0.58 0.58 0.57 0.57 0.58 0.57 0.57 0.58 0.58 0.58 0.59 0.59 0.58 0.59 0.57 0.58 0.59 0.65 0.91 0.57 1.1 0.56 0.58 0.58 0.56 0.58 0.57 0.58 0.58 0.56 0.59 0.57 0.57 0.59 0.57 0.56 0.58 0.58 0.58 0.59 0.59 0.57 0.59 0.57 0.57 0.59 0.58 0.58 0.58 0.57 0.58 0.58 0.58 0.57 0.58 0.58 0.58 0.58 0.58 1.2 0.57 0.58 0.57 0.58 0.58 0.58 0.58 0.58 0.57 0.58 0.57 0.7 0.58 0.58 0.57 0.57 0.58 0.58 0.58 0.58 0.58 0.58 0.58 0.58 1.3 0.59 0.58 0.62 0.57 0.63 0.58 0.58 0.58 0.58 0.58 0.58 0.57 0.58 0.58 0.58 0.58 0.58 0.58 0.58 89 89 89 89 89 89 89 89 89 89 89 90 90 90 90 90 90 91 91 91 91 91 91 91 92 92 92 91 92 91 91 91 91 91 91 91 92 91 92 92 91 93 91 92 92 92 92 71 71 71 71 72 70 70 70 69 65 65 88 88 87 89 89 89 89 89 89 88 88 88 88 89 88 88 88 88 88 89 88 88 89 89 89 89 89 88 90 95 96 95 96 94 90 89 88 88 89 88 88 88 88 88 88 89 89 8 8 8 8 8 8 8 8 8 8 8 8 7 7 7 7 7 7 6 6 7 6 7 7 6 6 6 7 6 6 6 7 7 7 7 6 6 6 6 6 6 5 6 6 6 6 6 21 22 22 21 21 22 22 22 23 28 28 8 8 9 8 8 8 8 8 8 9 9 8 8 8 8 8 8 8 8 8 8 8 8 7 7 7 7 7 7 4 3 3 3 4 7 8 9 9 8 9 9 8 8 8 8 8 8 1.05275 1.05852 1.06677 1.06769 1.07632 1.0758 1.05573 1.05561 1.07438 1.08096 1.06254 1.07806 1.07118 1.07185 1.08718 1.08101 1.08271 1.08344 1.09675 1.09675 1.09692 1.12553 1.10131 1.10612 1.12925 1.12658 1.1622 1.15408 1.16143 1.1706 1.19826 1.16734 1.16534 1.17805 1.15512 1.1885 1.14999 1.17028 1.15788 1.16533 1.14967 1.15579 1.16981 1.15682 1.17239 1.15944 1.1527 0.835141 0.838511 0.841407 0.821965 0.822425 0.835158 0.835069 0.821166 0.827159 0.814035 0.784493 1.04119 1.0116 1.04776 1.04776 1.11204 1.12363 1.11295 1.12825 1.12825 1.13595 1.02986 1.02738 1.023 1.0322 1.04317 1.04021 1.04472 1.05917 1.02829 1.02486 1.05553 1.04247 1.04247 1.05323 1.03189 1.04761 1.05575 1.06632 1.04069 1.06824 1.05889 1.02946 1.04946 1.04946 1.01472 1.01679 1.01456 1.02349 1.0281 1.02631 1.02631 1.00934 1.02987 1.03348 1.01822 1.01243 1.03573 Overall AvgFlux Overall Central Error Uniformity Shift Calibration 2 (%) (%) (%) Factor ( sec.) ( ions/(cm s) ) Dead Time -2.27 -0.683 0.931 0.931 0.931 0.931 0.931 0.931 2.531 4.119 -3.894 -2.307 -0.707 -0.707 -0.707 -0.707 -0.707 -0.707 -0.707 0.881 2.494 2.494 4.094 4.094 4.094 -3.844 -3.844 -3.844 -3.844 -3.844 -3.844 -2.244 -2.244 -0.657 -0.657 -0.657 0.955 0.955 0.955 0.955 2.543 2.543 2.543 4.142 4.142 4.142 2.531 -3.844 -3.844 -3.844 -3.844 -3.844 -3.844 -3.844 -3.844 -3.844 -3.844 -3.844 -3.844 -3.844 -3.844 -2.244 -2.244 -2.244 -2.244 -2.244 -2.244 -2.244 -2.244 -2.244 -2.244 -2.244 -2.244 -0.657 0.955 2.543 4.142 4.119 4.119 -3.894 -3.894 -2.307 -0.707 0.881 -2.307 -3.87 -2.27 -3.844 -3.844 -2.244 -2.244 0.955 0.955 0.955 0.955 0.955 0.955 -0.683 -0.683 -0.683 -0.683 -0.683 -0.683 -0.683 -0.683 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 0.046 0.072 2.384 2.384 2.433 2.433 2.433 2.433 2.433 2.433 2.433 2.433 2.483 2.483 2.508 2.508 2.508 -2.443 -2.443 -2.443 -2.443 -2.443 -2.443 -2.418 -2.418 -2.393 -2.393 -2.393 -2.393 -2.393 -2.393 -2.393 -2.343 -2.343 -2.343 -2.343 -2.343 -2.343 0.046 -2.443 -2.443 -2.443 -2.443 -2.443 -2.443 -2.443 -2.443 -2.443 -2.443 -2.443 -2.443 -2.443 -2.443 -2.418 -2.418 -2.418 -2.418 -2.418 -2.418 -2.418 -2.418 -2.418 -2.418 -2.418 -2.418 -2.393 -2.393 -2.343 -2.343 0.072 0.072 2.384 2.384 2.384 2.433 2.433 2.384 -0.003 -0.003 -2.443 -2.443 -2.418 -2.418 -2.393 -2.393 -2.393 -2.393 -2.393 -2.393 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -0.003 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 DUT Coordinates X (in) Y (in) Z (cm) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Degree DUT Tilt Angle 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Width 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Height Aperture (inch) 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Step 34.737 34.737 34.737 34.737 34.737 34.737 34.737 34.737 34.737 34.737 34.737 34.737 34.737 34.737 34.737 34.737 34.737 34.737 34.737 34.737 34.737 34.737 34.737 34.737 34.737 34.737 34.737 34.737 34.737 34.737 34.737 34.737 34.737 34.737 34.737 34.737 34.737 34.737 34.737 34.737 34.737 34.737 34.737 34.737 34.737 34.737 34.737 0 0 0 0 0 0 0 0 0 0 49.038 49.038 49.038 49.038 33.75 33.75 33.75 33.75 33.75 33.75 49.038 49.038 49.038 49.038 49.038 49.038 49.038 49.038 49.038 49.038 49.038 49.038 49.038 49.038 49.038 49.038 49.038 49.038 49.038 49.038 32.563 32.563 32.563 32.563 32.563 32.563 32.563 32.563 32.563 32.563 32.563 32.563 32.563 32.563 32.563 32.563 32.563 32.563 Degree Al Degrader Degrader No. Angle Detector Bias (V) 727_479_480_453_621 727_479_480_453_621 727_479_480_453_621 727_479_480_453_621 727_479_480_453_621 727_479_480_453_621 727_479_480_453_621 727_479_480_453_621 727_479_480_453_621 727_479_480_453_621 727_479_480_453_621 727_479_480_453_621 727_479_480_453_621 727_479_480_453_621 727_479_480_453_621 727_479_480_453_621 727_479_480_453_621 727_479_480_453_621 727_479_480_453_621 727_479_480_453_621 727_479_480_453_621 727_479_480_453_621 727_479_480_453_621 727_479_480_453_621 727_479_480_453_621 727_479_480_453_621 727_479_480_453_621 727_479_480_453_621 727_479_480_453_621 727_479_480_453_621 727_479_480_453_621 727_479_480_453_621 727_479_480_453_621 727_479_480_453_621 727_479_480_453_621 727_479_480_453_621 727_479_480_453_621 727_479_480_453_621 727_479_480_453_621 727_479_480_453_621 727_479_480_453_621 727_479_480_453_621 727_479_480_453_621 727_479_480_453_621 727_479_480_453_621 727_479_480_453_621 727_479_480_453_621 570_494_560_568_491 570_494_560_568_491 570_494_560_568_491 570_494_560_568_491 570_494_560_568_491 570_494_560_568_491 570_494_560_568_491 570_494_560_568_491 570_494_560_568_491 570_494_560_568_491 605_627_722_750_514 605_627_722_750_514 605_627_722_750_514 605_627_722_750_514 613_393_443_410_567 613_393_443_410_567 613_393_443_410_567 613_393_443_410_567 613_393_443_410_567 613_393_443_410_567 569_368_412_386_514 569_368_412_386_514 569_368_412_386_514 569_368_412_386_514 569_368_412_386_514 569_368_412_386_514 569_368_412_386_514 569_368_412_386_514 569_368_412_386_514 569_368_412_386_514 569_368_412_386_514 569_368_412_386_514 569_368_412_386_514 569_368_412_386_514 569_368_412_386_514 569_368_412_386_514 569_368_412_386_514 569_368_412_386_514 569_368_412_386_514 569_368_412_386_514 556_361_403_379_498 556_361_403_379_498 556_361_403_379_498 556_361_403_379_498 556_361_403_379_498 556_361_403_379_498 556_361_403_379_498 556_361_403_379_498 556_361_403_379_498 556_361_403_379_498 556_361_403_379_498 556_361_403_379_498 556_361_403_379_498 556_361_403_379_498 556_361_403_379_498 556_361_403_379_498 556_361_403_379_498 556_361_403_379_498 Run FileName IR_March_2006.#kf IR_March_2006.#kg IR_March_2006.#kh IR_March_2006.#ki IR_March_2006.#kj IR_March_2006.#kk IR_March_2006.#kl IR_March_2006.#km IR_March_2006.#kn IR_March_2006.#ko IR_March_2006.#kp IR_March_2006.#kq IR_March_2006.#kr IR_March_2006.#ks IR_March_2006.#kt IR_March_2006.#ku IR_March_2006.#kv IR_March_2006.#kw IR_March_2006.#kx IR_March_2006.#ky IR_March_2006.#kz IR_March_2006.#l0 IR_March_2006.#l1 IR_March_2006.#l2 IR_March_2006.#l3 IR_March_2006.#l4 IR_March_2006.#l5 IR_March_2006.#l6 IR_March_2006.#l7 IR_March_2006.#l8 IR_March_2006.#l9 IR_March_2006.#la IR_March_2006.#lb Run # 736 737 738 739 740 741 742 743 744 745 746 747 748 749 750 751 752 753 754 755 756 757 758 759 760 761 762 763 764 765 766 767 768 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 6/3/2024 Start Date 20:31:28 20:32:29 20:35:56 20:38:27 20:39:43 20:41:26 20:42:38 20:43:15 20:43:53 20:44:30 20:45:03 20:45:38 20:46:17 20:46:46 20:47:20 20:49:15 20:50:47 20:51:49 20:52:50 21:06:59 21:07:32 21:08:11 21:09:14 21:09:55 21:10:33 21:11:09 21:13:19 21:14:14 21:15:19 21:16:01 21:17:14 21:18:40 21:19:34 Start Time 00:00:28_(+_0_days) 00:00:28_(+_0_days) 00:00:34_(+_0_days) 00:00:25_(+_0_days) 00:00:25_(+_0_days) 00:00:23_(+_0_days) 00:00:27_(+_0_days) 00:00:21_(+_0_days) 00:00:20_(+_0_days) 00:00:21_(+_0_days) 00:00:20_(+_0_days) 00:00:20_(+_0_days) 00:00:19_(+_0_days) 00:00:19_(+_0_days) 00:00:18_(+_0_days) 00:00:30_(+_0_days) 00:00:22_(+_0_days) 00:00:22_(+_0_days) 00:00:20_(+_0_days) 00:00:20_(+_0_days) 00:00:22_(+_0_days) 00:00:15_(+_0_days) 00:00:23_(+_0_days) 00:00:23_(+_0_days) 00:00:23_(+_0_days) 00:00:21_(+_0_days) 00:00:46_(+_0_days) 00:00:31_(+_0_days) 00:00:27_(+_0_days) 00:00:29_(+_0_days) 00:00:29_(+_0_days) 00:00:37_(+_0_days) 00:00:38_(+_0_days) Run Duration 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Upset Events 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au 15.0_MeV/u__Au Selected Beam 1.187 1.187 1.187 1.187 1.187 1.187 1.187 1.187 1.187 1.187 1.187 1.187 1.187 1.187 1.187 1.187 1.187 1.187 1.187 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 ( µm ) Al Thk 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) 3_(IR_March_2006) # of Layers ( Filename ) 8.9 8.9 8.9 8.9 8.9 8.9 8.9 8.9 8.9 8.9 8.9 8.9 8.9 8.9 8.9 8.9 8.9 8.9 8.9 7.7 7.7 7.7 7.7 7.7 7.7 7.7 7.7 7.7 7.7 7.7 7.7 7.7 7.7 (MeV/amu) 1755 1755 1755 1755 1755 1755 1755 1755 1755 1755 1755 1755 1755 1755 1755 1755 1755 1755 1755 1510 1510 1510 1510 1510 1510 1510 1510 1510 1510 1510 1510 1510 1510 (MeV) Beam Energy silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon silicon 88.2 88.2 88.2 88.2 88.2 88.2 88.2 88.2 88.2 88.2 88.2 88.2 88.2 88.2 88.2 88.2 88.2 88.2 88.2 89.8 89.8 89.8 89.8 89.8 89.8 89.8 89.8 89.8 89.8 89.8 89.8 89.8 89.8 93.7 93.7 93.7 93.7 93.7 93.7 93.7 93.7 93.7 93.7 93.7 93.7 93.7 93.7 93.7 93.7 93.7 93.7 93.7 81.9 81.9 81.9 81.9 81.9 81.9 81.9 81.9 81.9 81.9 81.9 81.9 81.9 81.9 88.2 88.2 88.2 88.2 88.2 88.2 88.2 88.2 88.2 88.2 88.2 88.2 88.2 88.2 88.2 88.2 88.2 88.2 88.2 89.8 89.8 89.8 89.8 89.8 89.8 89.8 89.8 89.8 89.8 89.8 89.8 89.8 89.8 93.7 93.7 93.7 93.7 93.7 93.7 93.7 93.7 93.7 93.7 93.7 93.7 93.7 93.7 93.7 93.7 93.7 93.7 93.7 81.9 81.9 81.9 81.9 81.9 81.9 81.9 81.9 81.9 81.9 81.9 81.9 81.9 81.9 24 In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air In-air Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current Current 2.94E+05 2.97E+05 3.03E+05 3.04E+05 2.98E+05 2.95E+05 3.03E+05 3.08E+05 2.94E+05 2.97E+05 3.00E+05 3.00E+05 3.02E+05 3.00E+05 2.89E+05 2.98E+05 3.01E+05 3.02E+05 3.11E+05 2.93E+05 3.03E+05 1.75E+05 3.00E+05 2.97E+05 2.93E+05 2.94E+05 2.99E+05 2.96E+05 2.99E+05 2.97E+05 3.04E+05 3.04E+05 3.01E+05 Nominal Nominal Effective Effective Effective Target LET Range LET Range DUT Position Fluence 2 (MeV.cm /mg) Material (MeV.cm2/mg) Location Name ( ions/cm2 ) ( µm ) ( µm ) 4.16E+02 4.19E+02 4.29E+02 4.30E+02 4.21E+02 4.17E+02 4.27E+02 4.35E+02 4.15E+02 4.20E+02 4.24E+02 4.23E+02 4.27E+02 4.24E+02 4.09E+02 4.21E+02 4.25E+02 4.26E+02 4.40E+02 4.22E+02 4.36E+02 2.52E+02 4.31E+02 4.28E+02 4.21E+02 4.23E+02 4.31E+02 4.27E+02 4.30E+02 4.28E+02 4.37E+02 4.37E+02 4.33E+02 ( rad ) Dose International Rectifier Corp. SEE Test Report March 2006 – T.A.M.U. 24.15 23.75 21.4667 19.7167 18.7 17.0833 16.8167 16.4333 15.2333 15.55 15.6333 15.3667 14.85 14.4333 13.9167 13.45 15.55 13.85 14.3833 15.8333 17.35 10.4167 17.9333 18.3333 18.2667 17.5 23.0667 22.65 22.3833 23.8667 25.3333 31.4333 33.4667 ( sec.) Live Time 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1.22E+04 1.25E+04 1.41E+04 1.54E+04 1.59E+04 1.73E+04 1.80E+04 1.87E+04 1.93E+04 1.91E+04 1.92E+04 1.95E+04 2.03E+04 2.08E+04 2.08E+04 2.21E+04 1.94E+04 2.18E+04 2.17E+04 1.85E+04 1.75E+04 1.68E+04 1.67E+04 1.62E+04 1.60E+04 1.68E+04 1.30E+04 1.31E+04 1.34E+04 1.25E+04 1.20E+04 9.67E+03 9.00E+03 Average Flux 0.58 0.58 0.57 0.57 0.58 0.58 0.57 0.57 0.58 0.58 0.58 0.58 0.58 0.58 0.59 0.58 0.58 0.58 0.57 0.58 0.57 0.76 0.58 0.58 0.58 0.58 0.58 0.58 0.58 0.58 0.57 0.57 0.58 89 89 89 90 90 90 91 90 91 91 91 91 92 92 91 92 91 92 92 96 96 96 96 96 96 96 95 97 96 96 96 95 94 8 8 8 7 7 7 6 7 6 6 6 6 6 6 6 6 6 6 5 3 3 3 3 3 3 3 3 2 2 3 3 3 4 1.04155 1.02558 1.04706 1.0259 1.03076 1.0367 1.04364 1.03364 1.05944 1.04743 1.03987 1.04248 1.05719 1.02572 1.03425 1.02719 1.04181 1.02968 1.05257 1.08813 1.06413 1.05877 1.06683 1.06713 1.02355 1.07586 1.06515 1.07566 1.07566 1.06312 1.0454 1.07424 1.0659 Overall AvgFlux Overall Central Error Uniformity Shift Calibration 2 Factor (%) (%) (%) ( sec.) ( ions/(cm s) ) Dead Time -0.683 -0.683 0.931 2.531 4.119 -3.894 -2.307 -2.307 -2.307 -2.307 -2.307 -2.307 -2.307 -2.307 -2.307 -0.707 0.881 2.494 4.094 -3.844 -3.844 -3.844 -2.244 -2.244 -2.244 -2.244 -0.657 -0.657 0.955 0.955 2.543 4.142 4.142 -0.003 -0.003 -0.003 0.046 0.072 2.384 2.384 2.384 2.384 2.384 2.384 2.384 2.384 2.384 2.384 2.433 2.433 2.483 2.508 -2.443 -2.443 -2.443 -2.418 -2.418 -2.418 -2.418 -2.393 -2.393 -2.393 -2.393 -2.343 -2.343 -2.343 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 -6.02 DUT Coordinates X (in) Y (in) Z (cm) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Degree DUT Tilt Angle 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Width 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Height Aperture (inch) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Step 32.563 32.563 32.563 32.563 32.563 32.563 32.563 32.563 32.563 32.563 32.563 32.563 32.563 32.563 32.563 32.563 32.563 32.563 32.563 51.313 51.313 51.313 51.313 51.313 51.313 51.313 51.313 51.313 51.313 51.313 51.313 51.313 51.313 Degree Al Degrader Degrader No. Angle Detector Bias (V) 556_361_403_379_498 556_361_403_379_498 556_361_403_379_498 556_361_403_379_498 556_361_403_379_498 556_361_403_379_498 556_361_403_379_498 556_361_403_379_498 556_361_403_379_498 556_361_403_379_498 556_361_403_379_498 556_361_403_379_498 556_361_403_379_498 556_361_403_379_498 556_361_403_379_498 556_361_403_379_498 556_361_403_379_498 556_361_403_379_498 556_361_403_379_498 572_370_414_388_518 572_370_414_388_518 572_370_414_388_518 572_370_414_388_518 572_370_414_388_518 572_370_414_388_518 572_370_414_388_518 572_370_414_388_518 572_370_414_388_518 572_370_414_388_518 572_370_414_388_518 572_370_414_388_518 572_370_414_388_518 572_370_414_388_518 International Rectifier Corp. SEE Test Report March 2006 – T.A.M.U. Appendix C International Rectifier Test Plan and Procedure 25 International Rectifier Corp. SEE Test Report March 2006 – T.A.M.U. March 2006 Test Plan, Single Event Effects (TAMU, K500 Superconducting Cyclotron) 1.0 Purpose The purpose of this test is to characterize and establish Single Event Effects (SEE) Safe-Operating-Area (SOA) curves for several International Rectifier Corp. (IR) Power MOSFET devices. The data resulting from the tests shall be used for qualification to several US Government military slash sheets and shall be incorporated in the IR data sheets. 2.0 Test Responsibility IR shall be responsible for conducting the tests, which shall be performed at the Texas A & M University (TAMU), Cyclotron Institute. IR shall be responsible for the SEE testing of devices-under-test (DUT) and final Test Report. 3.0 Test Facility 3.1 Accelerator The Texas A&M University, Tandem K500 Superconducting Cyclotron shall be used to provide the necessary ion species and energy. TAMU Cyclotron Institute shall provide adequate dosimeter for verification of the ion beam parameters. 3.2 Test Equipment The necessary test equipment including the test interface board, cables, power supplies, etc. shall be provided by IR. IR shall provide the equipment needed to de-lid and handle the individual test devices. 4.0 Test Devices 4.1 The following device types are planned for characterization / qualification: IRH67C30 (Size-3, 600V, N-channel, R6, MR Process) IRHL77214 (Size-1, 250V, N-channel, R7, LOGIC Process) IRH7360SE (Size-6, 400V, N-channel, G4, MR Process) IRH67230 (Size-3, 200V, N-channel, R6, MR Process) IRHL77110 (Size-1, 100V, N-channel, R7, LOGIC Process) IRHL770Z4 (Size-Z, 60V, N-channel, R7, LOGIC Process) IRHL7970Z4 (Size-Z, 60V, P-channel, R7, LOGIC Process) 4.2 All devices shall be built in TO-3 packages. The devices shall be properly sealed and packed for transportation to TAMU Cyclotron Institute. 4.3 All devices shall be verified for correct electrical performance prior to arrival at TAMU. 5.0 Test Method The MIL-STD-750, Method 1080 shall be used to set procedure for all testing described herein. 6.0 Ion Specie and Energy There are three (3) available ion specie chosen, each with different energy level, at TAMU 15AMeV SetUp. All parts will be first tested with one specie of lowest energy (LET) level before the Cyclotron is switched to the next ion specie with higher energy level. Energy = 1259 MeV max, LET = 25.4-41.4 MeV/(mg/cm2), Range = 21-170 µm a. Krypton 36Kr84 b. Xenon 54Xe 129 Energy = 1934 MeV max, LET = 47.3-63.4 MeV/(mg/cm2), Range = 31-156 µm c. Gold 79Au 197 Energy = 2955 MeV max, LET = 80.2-93.5 MeV/(mg/cm2), Range = 53-155 µm (Refer to 15AMeV Air-Gap Table for Available Energy, LET and Range with 1.50cm air gap testing) 26 International Rectifier Corp. SEE Test Report March 2006 – T.A.M.U. 7.0 Record Keeping Each irradiation shall be assigned a run number. This number will be used to correlate data from different sources. 7.1 Cyclotron Accelerator Output The K500 Cyclotron Institute shall provide a hardcopy summary of all test runs showing key parameters such as run, date, time, flux, fluence, ion, energy, LET, and range. A separate output of beam diagnostics shall also be provided. 7.2 IR Output IR shall also keep a written log of each run including run, ion, device tested, VDS and VGS biases. IR shall also record comments regarding the test including observations or deviations from test plan. 8.0 Characterizations and Verification Characterization and Verification may be accomplished simultaneously. Characterization implies that the SOA curve is set using at least one (1) device at each insitu bias. Verification is simply an extension of the characterization, demonstrating two (2) additional devices passing at each insitu bias, for a total of three (3) devices per insitu bias condition. 9.0 Test Procedure The IR Product Engineer assigned to this test shall control the following test procedure based on Test Method 1080. IR shall be responsible to direct the ion specie, beam characteristics, insitu bias conditions and device selection. 9.1 Nominal Beam Characteristics are : Flux = 1x104 (1E4) ions/cm2/sec. Fluence = 3x105 (3E5) ions/cm2. Beam Aperture = 2 in x 2 in. (or large enough to cover the whole die-attachment area) 9.2 Initial Starting Point : typically at VDS =Rated VDS and VGS = 0. 9.3 Irradiate the device at the selected flux and fluence. 9.4 Post irradiation, test IDSS & IGSS at VDS=80% Rated VDS and VGS up to 20 V (5 V increment). 9.5 Based on apparent pass or fail, select next operating conditions. 9.6 Repeat with new device. 10. Test Report The Test Report shall include the following information : a. Device Type(s), serial numbers, wafer lot identification, date code (if applicable). b. Test dates and personnel names. c. Facility, accelerator type. d. Ion specie, energy, LET, range, flux and fluence. e. Schematic of test circuit used. f. Dosimeter for each ion beam used. g. Insitu bias conditions. h. Comments and observations. i. Pre and post electrical test results. j. Summary description including curves. 27 International Rectifier Corp. SEE Test Report March 2006 – T.A.M.U. Appendix D Test Circuit Schematic Diagram 28 International Rectifier Corp. SEE Test Report March 2006 – T.A.M.U. Reference: MIL-STD-750, Method 1080 Details of Test Method can be reviewed from DSCC Website: www.dscc.dla.Downloads/MilSpec/Docs/MIL-STD-750/std750_1000.pdf Test Circuit Schematic Diagram 29 International Rectifier Corp. SEE Test Report March 2006 – T.A.M.U. Appendix E TAMU K500 Cyclotron Ion Species, Surface LET and Range 30 International Rectifier Corp. SEE Test Report March 2006 – T.A.M.U. 31 International Rectifier Corp. SEE Test Report March 2006 – T.A.M.U. 32 International Rectifier Corp. SEE Test Report March 2006 – T.A.M.U. 33 International Rectifier Corp. SEE Test Report March 2006 – T.A.M.U. 34 International Rectifier Corp. SEE Test Report March 2006 – T.A.M.U. Appendix F Post-SEE Electrical Measurements 35 International Rectifier Corp. SEE Test Report March 2006 – T.A.M.U. 36 International Rectifier Corp. SEE Test Report March 2006 – T.A.M.U. 37 International Rectifier Corp. SEE Test Report March 2006 – T.A.M.U. 38