Preview only show first 10 pages with watermark. For full document please download

Fire Alarm Wires

   EMBED


Share

Transcript

Multi-Conductor, Unshielded, Non-Plenum Product Construction NEC Type FPLR CONDUCTOR: s Solid bare copper INSULATION: NO. OF COND. AWG. SIZE NOM. JACKET WALL s WEIGHT JACKET: s COND. STRAND INCHES MM INCHES MM INCHES POUNDS Solid Solid Solid Solid 0.010 0.010 0.010 0.010 0.25 0.25 0.25 0.25 0.015 0.015 0.015 0.015 0.38 0.38 0.38 0.38 0.150 0.175 0.210 0.230 16 lbs. 29 lbs. 41 lbs. 53 lbs. 18 AWG CONDUCTORS s W181P-1604 W184C-1602 W186C-1654 W188C-1667 2 4 6 8 18 18 18 18 s s Solid Solid 0.010 0.010 0.25 0.25 0.015 0.015 0.38 0.38 0.172 0.202 23 lbs. 42 lbs. 14 AWG CONDUCTORS W141P-1607 2 14 W144C-1651 4 14 Solid Solid 0.013 0.013 0.33 0.33 0.015 0.015 0.38 0.38 0.210 0.248 36 lbs. 66 lbs. s s s s s 0.013 0.013 0.33 0.33 0.015 0.015 0.38 0.38 0.244 0.288 53 lbs. 99 lbs. Wiring of fire alarms Smoke detectors Voice communications Burglar alarms Fire protective circuits Suggested voltage rating: 300 volts COMPLIANCES: s Solid Solid Premium grade, Red PVC, other jacket colors may be available – consult sales office Suitable for use from 20˚C to + 75˚C Round constructions have sequential footage markings to facilitate installation Includes ripcord on round constructions APPLICATIONS: s 16 AWG CONDUCTORS W161P-1601 2 16 W164C-1614 4 16 12 AWG CONDUCTORS W121P-1624 2 12 W124C-1656 4 12 Premium grade, color coded, S-R PVC NOMINAL O.D. FIRE ALARM/ LIFE SAFETY PART NUMBER NOM. INSUL. THICKNESS s s s UL Type FPLR (UL: 75˚C, 300V) NEC Article 760 California State Fire Marshall Approved Designed to meet UL 1666 Flame Test PACKAGING: Color Code Chart NO. OF COND. COLOR NO. OF COND. COLOR 1 2 3 Black Red Brown 5 6 7 Orange Yellow Violet 4 Blue 8 Gray s s 1000’ (305m) Reels Other put-ups available– consult Customer Service Multi-Conductor, Shielded, Non-Plenum Product Construction NEC Type FPLR CONDUCTOR: s Solid bare copper INSULATION: s Premium grade, color coded, S-R PVC SHIELD: PART NUMBER NO. OF COND. AWG. SIZE s COND. STRAND NOM. INSUL. THICKNESS INCHES MM NOM. JACKET WALL INCHES MM NOMINAL O.D. INCHES WEIGHT POUNDS Solid Solid 0.010 0.010 0.015 0.015 0.158 0.183 19 lbs. 32 lbs. JACKET: 18 AWG CONDUCTORS W181P-1603 W184C-1605 2 4 18 18 0.25 0.25 0.38 0.38 s s s 16 AWG CONDUCTORS W161P-1606 2 16 W164C-1628 4 16 Solid Solid 0.010 0.010 0.25 0.25 0.015 0.015 0.38 0.38 0.180 0.210 26 lbs. 42 lbs. 14 AWG CONDUCTORS W141P-1600 2 14 W144C-1650 4 14 Solid Solid 0.013 0.013 0.33 0.33 0.015 0.015 0.38 0.38 0.218 0.253 41 lbs. 76 lbs. 12 AWG CONDUCTORS W121P-1653 2 12 W124C-1659 4 12 s Overall Flexfoil® polyester supported aluminum foil Stranded tinned copper drain wire s APPLICATIONS: s s s s Solid Solid 0.013 0.013 0.33 0.33 0.015 0.015 0.38 0.38 0.252 0.293 56 lbs. 115 lbs. s s s NO. OF COND. COLOR NO. OF COND. COLOR s 1 2 3 4 Black Red Brown Blue 5 6 7 8 Orange Yellow Violet Gray s YOUR WIRE AND CABLE CONNECTION Wiring of fire alarms Smoke alarms Voice communications Burglar alarms Fire protective circuits Suggested voltage rating: 300 volts COMPLIANCES: s Color Code Chart Premium grade, Red PVC, other jacket colors may be available – consult sales office Suitable for use from 0°C to + 75°C Sequential footage markings to facilitate installation Includes ripcord UL Type FPLR (UL: 75°C, 300V) NEC Article 760 California State Fire Marshall Approved Designed to Meet UL 1666 Flame Test PACKAGING: s s 1000’ (305m) Reels Other put-ups available– consult Customer Service [email protected] Sales@Connectt-Ai Air. r.co com co m 11 Mid-Capacitance, Shielded, Non-Plenum Product Construction NEC Type FPL for Microprocessor Controlled Systems INSULATION: CONDUCTOR: s s s Solid bare copper Premium grade color coded polypropylene Color code: see chart below SHIELD: FIRE ALARM/ LIFE SAFETY s s 100% Flexfoil® aluminum/polyester, 25% overlap, minimum Stranded tinned copper drain wire JACKET: s PART NUMBER NOM. INSUL. THICKNESS NOM. JACKET WALL NOMINAL O.D. NO. OF COND. AWG. SIZE COND. STRAND INCHES MM INCHES MM INCHES 2 2 2 18 16 14 Solid Solid Solid 0.014 0.016 0.018 0.36 0.41 0.46 0.020 0.020 0.020 0.51 0.51 0.51 0.182 0.214 0.287 NOMINAL PF/FT A* B* WEIGHT POUNDS s APPLICATIONS: s W181P-1608 W161P-1609 W141P-1649 27.0 49.0 22 lbs. 29.0 52.0 30 lbs. 31.0 55.5 47 lbs. s s s s *A – Capacitance between conductors *B – Capacitance between one conductor and other conductors connected to shield Color Code Chart NO. OF COND. 1 2 3 4 COLOR Black Red Brown Blue PVC, red Temperature range: 0°C to + 60°C s Addressable fire alarm systems Fire alarm systems Voice communications Smoke detectors Pull boxes Suggested voltage rating: 300 volts COMPLIANCES: s s s s UL Type FPL (UL: 60°C, 300V) NEC Article 760 California State Fire Marshall Approved Passes UL 70,000 BTU Vertical Tray Flame Test PACKAGING: s 1000’ s Mid-Capacitance, Unshielded, Non-Plenum (30 m) reels Other put-ups available– consult Customer Service Product Construction CONDUCTOR: s NEC Type FPL for Microprocessor Controlled Systems 18 thru 12 AWG fully annealed solid bare copper per ASTM B3 INSULATION: s Premium grade color coded polypropylene s Color code: see chart below JACKET: s s PVC, red Temperature range: – 20°C to + 60°C APPLICATIONS: PART NUMBER W181P-1617 W161P-1647 W141P-1656 NOM. INSUL. THICKNESS NOM. JACKET WALL NO. OF COND. AWG. SIZE COND. STRAND INCHES MM INCHES MM 2 2 2 18 16 14 Solid Solid Solid 0.014 0.016 0.018 0.36 0.41 0.46 0.020 0.020 0.020 0.51 0.51 0.51 NOMINAL O.D. Addressable fire alarm systems Fire alarm systems s Voice communications s Smoke detectors s Pull boxes s Suggested voltage rating: 300 volts s INCHES NOM. C-C CAP. PF/FT* WEIGHT POUNDS 0.177 0.206 0.240 16.5 17.5 18.0 22 lbs. 30 lbs. 38 lbs. s COMPLIANCES: s UL Type FPL (UL: 60°C, 300V) NEC Article 760 s California State Fire Marshall Approved s Passes UL 70,000 BTU Vertical Tray Flame Test s Color Code Chart NO. OF COND. 1 2 3 4 12 CONNECT-AIR WIRE AND CABLE COLOR Black Red Brown Blue PACKAGING: 1000’ (305m) Reels 500’ (152m) Reels s Other put-ups available– consult Customer Service s s Multi-Conductor, Shielded, Direct Burial Product Construction NEC Type FPL / PLTC 300V INSULATION: CONDUCTOR: s s s Stranded copper per ASTM B3 PVC with nylon Color code: see chart below SHIELD: s JACKET: s s PART NUMBER W181P-1676 W161P-1661 W141P-1662 NO. OF COND. AWG. SIZE COND. STRAND 2 2 2 18 16 14 7/26 7/24 19/27 NOM. INSUL. THICKNESS INCHES MM NOM. JACKET WALL INCHES 0.015 0.005 0.040 0.015 0.005 0.040 0.015 0.005 0.040 NOMINAL O.D. MM INCHES WEIGHT POUNDS 1.02 1.02 1.02 0.310 0.328 0.350 48 lbs. 58 lbs. 75 lbs. s APPLICATIONS: s s s s s Color Code Chart NO. OF COND. PVC, Black Temperature range: – 20°C to + 105°C dry locations, 75°C wet locations Includes ripcord FIRE ALARM/ LIFE SAFETY s 100% Flexfoil® aluminum/polyester foil, 25% overlap, minimum Stranded tinned copper drain wire COLOR 1 2 3 Black Red Brown 4 Blue Fire alarm systems Smoke detectors Fire protective circuits Burglar alarms Suggested voltage rating: 300 volts COMPLIANCES: s s s UL Type PLTC/FPLR (UL: 105°C, 300V) NEC Article 760 California State Fire Marshall Approved FEATURES: s s s Sunlight and moisture resistant jacket Sequentially footage marked Water blocked construction PACKAGING: s s 1000’ (305m) Reels Other put-ups available– consult Customer Service Product Construction Multi-Conductor, Unshielded, Direct Burial CONDUCTOR: s Stranded bare copper INSULATION: NEC Type FPL / PLTC 300V s s PVC with nylon Color code: see chart below JACKET: s s s PVC, Black Temperature range: – 20°C to + 105°C dry locations, 75°C wet locations Includes ripcord APPLICATIONS: s PART NUMBER NOM. INSUL. THICKNESS NOM. JACKET WALL NOMINAL O.D. s NO. OF COND. AWG. SIZE COND. STRAND INCHES MM INCHES MM INCHES WEIGHT POUNDS 2 4 2 2 4 18 18 16 14 14 7/26 7/26 7/24 19/27 19/27 0.015 0.015 0.015 0.015 0.015 0.005 0.005 0.005 0.005 0.005 0.040 0.040 0.040 0.040 0.040 1.02 1.02 1.02 1.02 1.02 0.270 0.327 0.295 0.310 0.395 37 lbs. 59 lbs. 48 lbs. 59 lbs. 98 lbs. s s s W181P-1679 W184C-1693 W161P-1657 W141P-1663 W144C-1699 Fire alarm systems Voice communications Smoke detectors Burglar Alarms Suggested voltage rating: 300 volts COMPLIANCES: s s s UL Type PLTC/FPLR (UL: 105°C, 300V) NEC Article 760 California State Fire Marshall Approved FEATURES: s Color Code Chart s Sunlight and moisture resistant jacket Sequentially footage marked Water blocked construction COLOR s 1 2 3 Black Red Brown PACKAGING: 4 Blue NO. OF COND. YOUR WIRE AND CABLE CONNECTION s s 1000’ (305m) Reels Other put-ups available– consult Customer Service [email protected] Sales@Connectt-Ai Air. r.co com co m 13 Multi-Conductor, Type MC FPLP/MC 300V/600V Product Construction Red Fire Alarm/Control Cable™ ARMOR: s Galvanized interlocking Steel Strip (red-striped) CONDUCTORS: FIRE ALARM/ LIFE SAFETY s Solid copper CONDUCTOR INSULATION: s AFC Cable Systems ASSEMBLY: Multi-Conductor, Unshielded, Type MC PART NUMBER NO. OF COND. s 2 4 COND. STRAND NOMINAL O.D. WEIGHT 18 18 Solid Solid 0.410 0.430 115 lbs. 130 lbs. s Solid Solid 0.420 0.440 130 lbs. 155 lbs. 14 AWG CONDUCTORS W141P-1607MC 2 14 W144C-1651MC 4 14 Solid Solid 0.470 0.510 175 lbs. 230 lbs. s s s s Multi-Conductor, Type CI COND. STRAND NOMINAL O.D. NO. OF AWG. COND. SIZE COND. STRAND NOMINAL O.D. CONDUCTOR: s WEIGHT 18 18 Solid Solid 0.390 0.445 82 lbs. 127 lbs. W181P-1603CI W184C-1605CI 2 4 18 18 Solid Solid 0.310 0.355 s 54 lbs. 77 lbs. 14 AWG CONDUCTORS W141P-1607CI 2 14 W144C-1651CI 4 14 Solid Solid Solid* Solid* 0.350 0.400 0.390 0.445 64 lbs. 96 lbs. 16 AWG CONDUCTORS W161P-1606CI 2 16 W164C-1628CI 4 16 Solid Solid 0.330 0.375 82 lbs. 127 lbs. 14 AWG CONDUCTORS W141P-1600CI 2 14 W144C-1650CI 4 14 Solid* Solid* 0.370 81 lbs. 0.425 126 lbs. 2-hour fire rated – FPLR-CI COMPLIANCES: s 16 AWG CONDUCTORS W161P-1601CI 2 16 W164C-1614CI 4 16 Solid copper APPLICATIONS: 18 AWG CONDUCTORS 18 AWG CONDUCTORS 2 4 PART NUMBER 300V (FPLP) 600V (MC) CI Product Construction Multi-Conductor, Shielded, Type CI WEIGHT FPLP: 105° (dry) MC: 90° (dry) MAXIMUM VOLTAGE RATING: s NO. OF AWG. COND. SIZE Cable tray installations per NEC NFPA 262 (formerly U.L. 910) Plenum rated – Type FPLP MAXIMUM TEMPERATURE RATING: s Multi-Conductor, Unshielded, Type CI Fire Alarm/Control Type MC – FPLP COMPLIANCES: s W181P-1604CI W184C-1602CI Bare or insulated green APPLICATIONS: 16 AWG CONDUCTORS W161P-1601MC 2 16 W164C-1614MC 4 16 PART NUMBER Polyester assembly tape GROUNDING: AWG. SIZE 18 AWG CONDUCTORS W181P-1604MC W184C-1602MC TFN and/or THHN s 63 lbs. 96 lbs. UL 2196 NFPA 262 (formerly U.L. 910) MAXIMUM VOLTAGE RATING: s FPL – 300V *May be stranded construction. Consult your sales representative. CIC Product Construction Multi-Conductor, Type CIC Multi-Conductor, Unshielded, Type CIC PART NUMBER NO. OF COND. AWG. SIZE COND. STRAND NOMINAL O.D. WEIGHT 18 AWG CONDUCTORS W181P-1604CIC W184C-1602CIC 2 4 PART NUMBER NO. OF COND. s 18 18 Solid Solid 0.330 0.370 AWG. SIZE COND. STRAND NOMINAL O.D. WEIGHT 18 18 Solid Solid 0.330 0.385 57 lbs. 81 lbs. W181P-1603CIC W184C-1605CIC 62 lbs. 94 lbs. 16 AWG CONDUCTORS W161P-1606CIC 2 16 W164C-1628CIC 4 16 Solid Solid 0.350 0.400 66 lbs. 99 lbs. 14 AWG CONDUCTORS W141P-1600CIC 2 14 Solid* 0.400 85 lbs. W144C-1650CIC Solid* 0.450 130 lbs. 16 AWG CONDUCTORS W161P-1601CIC 2 16 W164C-1614CIC 4 16 Solid Solid 0.330 0.400 14 AWG CONDUCTORS W141P-1607CIC 2 14 W144C-1651CIC 4 14 Solid* Solid* 0.390 80 lbs. 0 440 125 lbs. CONNECT-AIR WIRE AND CABLE 4 s 2-hour fire rated – FPL/-NPLF COMPLIANCES: 53 lbs. 76 lbs. 2 4 Solid copper APPLICATIONS: 18 AWG CONDUCTORS *May be stranded construction. Consult your sales representative. 14 CONDUCTOR: Multi-Conductor, Shielded, Type CIC 14 s s UL 2196 NFPA 262 (formerly U.L. 910) MAXIMUM VOLTAGE RATING: s s FPL – 300V NPLR – 150V NOTE: 2-hour rated cable must be installed in conduit for any high-rise building over 75 feet, any federal building, and areas of assembly (1000 or more people). Multi-Conductor, Unshielded, Plenum Product Construction CONDUCTOR: NEC Type FPLP s 18 thru 12 AWG fully annealed solid bare copper per ASTM B3 INSULATION: s Premium grade, color coded, Plenum Rated PVC JACKET: AWG. SIZE COND. STRAND 18 AWG CONDUCTORS W181P-2600 2 18 W184C-2607 4 18 W186C-2651 6 18 Solid Solid Solid 0.010 0.010 0.010 0.25 0.25 0.25 0.015 0.015 0.015 0.38 0.38 0.38 0.155 0.175 0.211 17 lbs. 30 lbs. 57 lbs. 16 AWG CONDUCTORS W161P-2601 2 16 W164C-2637 4 16 Solid Solid 0.010 0.010 0.25 0.25 0.015 0.015 0.38 0.38 0.172 0.202 24 lbs. 45 lbs. 14 AWG CONDUCTORS W141P-2611 2 14 W144C-2640 4 14 Solid Solid 0.012 0.012 0.30 0.30 0.015 0.015 0.38 0.38 0.210 0.243 36 lbs. 66 lbs. 12 AWG CONDUCTORS W121P-2613 2 12 W124C-2641 4 12 Solid Solid 0.012 0.012 0.30 0.30 0.015 0.015 0.38 0.38 0.244 0.284 52 lbs. 100 lbs. PART NUMBER NO. OF COND. NOM. JACKET WALL INCHES MM NOMINAL O.D. INCHES WEIGHT POUNDS Premium grade, Red Plenum Rated PVC, other jacket colors may be available – consult sales office s Suitable for use from 0°C to + 75°C s Sequential footage markings to facilitate installation s Includes ripcord APPLICATIONS: FIRE ALARM/ LIFE SAFETY s NOM. INSUL. THICKNESS INCHES MM s Wiring of fire alarms Smoke detectors s Voice communications s Burglar alarms s Fire protective circuits s Suggested voltage rating: 300 volts s COMPLIANCES: Color Code Chart s UL Type FPLP (UL: 75°C, 300V) NEC Article 760 s California State Fire Marshall Approved s Designed to meet UL 910 flame test s PACKAGING: NO. OF COND. COLOR NO. OF COND. COLOR s 1 2 3 Black Red Brown 4 5 6 Blue Orange Yellow s 1000’ (305m) Reels Other put-ups available– consult Customer Service Product Construction Multi-Conductor, Shielded, Plenum CONDUCTOR: NEC Type FPLP INSULATION: s s Solid bare copper Premium grade, color coded, Plenum Rated PVC SHIELD: s s 100% aluminum foil/polyester Stranded tinned copper drain wire JACKET: PART NUMBER NO. OF COND. AWG. SIZE s COND. STRAND NOM. INSUL. THICKNESS INCHES MM NOM. JACKET WALL INCHES MM NOMINAL O.D. INCHES WEIGHT POUNDS Solid Solid Solid 0.010 0.010 0.010 0.015 0.015 0.015 0.155 0.183 0.216 21 lbs. 34 lbs. 47 lbs. 18 AWG CONDUCTORS W181P-2601 W184C-2621 W186C-2644 2 4 6 18 18 18 0.25 0.25 0.25 0.38 0.38 0.38 Premium grade, Red Plenum Rated PVC, other jacket colors may be available – consult sales office s Suitable for use from 0°C to + 75°C s Sequential footage markings to facilitate installation s Includes ripcord APPLICATIONS: s 16 AWG CONDUCTORS W161P-2602 2 16 W164C-2604 4 16 Solid Solid 0.010 0.010 0.25 0.25 0.015 0.015 0.38 0.38 0.180 0.210 28 lbs. 49 lbs. 14 AWG CONDUCTORS W141P-2605 2 14 W144C-2642 4 14 Solid Solid 0.012 0.012 0.30 0.30 0.015 0.015 0.38 0.38 0.210 0.248 43 lbs. 76 lbs. 12 AWG CONDUCTORS W121P-2645 2 12 W124C-2641 4 12 Wiring of fire alarms Smoke detectors s Voice communications s Burglar alarms s Fire protective circuits s Suggested voltage rating: 300 volts s COMPLIANCES: s UL Type FPLP (UL: 75°C, 300V) NEC Article 760 s California State Fire Marshall Approved s Designed to meet UL 910 Flame Test s Solid Solid 0.012 0.012 0.30 0.30 0.015 0.015 0.38 0.38 0.252 0.300 57 lbs. 114 lbs. PACKAGING: 1000’ (305m) Pull-Pac® Cartons (18 and 16 AWG items only) s 1000’ (305m) reels s 500’ (152m) spools or reels s Other put-ups available– consult Customer Service s Color Code Chart NO. OF COND. COLOR NO. OF COND. COLOR 1 2 3 Black Red Brown 4 5 6 Blue Orange Yellow YOUR WIRE AND CABLE CONNECTION [email protected] Sales@Connectt-Ai Air. r.co com co m 15 Mid-Capacitance, Shielded, Plenum Product Construction CONDUCTOR: NEC Type FPLP for Microprocessor Controlled Systems s Solid bare copper INSULATION: s Premium grade color coded Fluoropolymer s Color code: see chart below FIRE ALARM/ LIFE SAFETY SHIELD: s PART NUMBER W181P-2620 W161P-2634 W141P-2635 NO. OF COND. AWG. SIZE COND. STRAND NOM. INSUL. THICKNESS INCHES MM 2 2 2 18 16 14 Solid Solid Solid 0.014 0.016 0.018 0.36 0.41 0.46 NOM. JACKET WALL INCHES MM NOMINAL O.D. INCHES 0.015 0.015 0.020 0.172 22 lbs. 31.0 56.0 0.203 35 lbs. 33.0 59.0 0.247 35 lbs. 35.0 63.0 0.38 0.38 0.51 NOMINAL CAP.* PF/FT A* B* WEIGHT LBS s 100% aluminum/polyester foil Stranded tinned copper drain wire JACKET: Premium grade, Red Plenum Rated PVC Temperature range: 0°C to + 75°C s Includes ripcord s s APPLICATIONS: s *A – Capacitance between conductors *B – Capacitance between one conductor and other conductors connected to shield Addressable fire alarm systems Fire alarm systems s Voice communications s Smoke detectors s Pull boxes s Suggested voltage rating: 300 volts s Color Code Chart NO. OF COND. 1 2 3 4 COLOR Black Red Brown Blue COMPLIANCES: s UL Type FPLP (UL: 75°C, 300V) NEC Article 760 s California State Fire Marshall Approved s Designed to Meet UL 910 Flame Test s PACKAGING: s s Mid-Capacitance, Unshielded, Plenum Product Construction CONDUCTOR: s NEC Type FPLP for Microprocessor Controlled Systems 1000’ (30 m) Reels Other put-ups available– consult Customer Service Solid bare copper INSULATION: s Premium grade color coded Fluoropolymer s Color code: see chart below JACKET: s Premium grade, Red Plenum Rated PVC Temperature range: 0°C to + 75°C s Includes ripcord s PART NUMBER NO. OF COND. AWG. SIZE COND. STRAND NOM. INSUL. THICKNESS INCHES MM NOM. JACKET WALL INCHES MM NOMINAL O.D. INCHES WEIGHT POUNDS NOMINAL C-CAP. PF/FT* 2 2 2 2 18 16 14 12 Solid Solid Solid Solid 0.014 0.016 0.018 0.020 0.015 0.015 0.020 0.020 0.172 0.196 0.242 0.282 18 lbs. 31 lbs. 43 lbs. 63 lbs. 19.0 20.0 20.0 22.0 APPLICATIONS: s W181P-2622 W161P-2633 W141P-2646 W121P-2643 0.36 0.41 0.46 0.46 0.38 0.38 0.51 0.51 * Capacitance between conductors Addressable fire alarm systems Fire alarm systems s Voice communications s Smoke detectors s Pull boxes s Suggested voltage rating: 300 volts s COMPLIANCES: s Color Code Chart NO. OF COND. 1 2 3 4 16 CONNECT-AIR WIRE AND CABLE COLOR Black Red Brown Blue UL Type FPLP (UL: 75°C, 300V) NEC Article 760 s California State Fire Marshall Approved s Designed to Meet UL 910 Flame Test s PACKAGING: s s 1000’ (305m) Reels Other put-ups available– consult Customer Service