Preview only show first 10 pages with watermark. For full document please download

Fire - City Of Daytona Beach

   EMBED


Share

Transcript

CITY OF DAYTONA BEACH DEVELOPMENT SERVICES DEPARTMENT PERMIT & LICENSING DIVISION BUILDING PERMIT PERMIT TYPE: FIRE PERMIT NUMBER: C1503-083 ALARM job address: 2461 N Atlantic Av PARCEL/TAX ID NO: 25143201120010 New fire alarm for Marshalls #228 SUBDIVISION: APPLICATION DATE 03/19/2015 APPROVAL DATE 03/23/2015 PERMIT/ISSUE DATE 03/26/2015 LOT: BLOCK: 01-12 CONSTRUCTION TYPE: CONTACT INFORMATION Owner: G&l VII BELLAIR PLAZA LLC Mailing Addr: Applicant: Phone: 220 E 42ND ST NEW YORK NY 10017 Fax: Seminole Safety Systems Inc (E Mailing Addr: Phone: Casselberry FL Fax: Contractor Seminole Safety Systems Inc (E Phone: Mailing Addr: Fax: FEES CONDITIONS (407) 830-5330 Casselberry FL (407) 830-5330 ESTIMATED VALUATION FEES PAID AMOUNT DUE $15,500.00 $234.56 $234.56 $0.00 This permit is issued pursuant to the attached conditions. Failure to comply may result in suspension or revocation of this permit or other penalty. Permit expires 180 days from date issued unless otherwise noted or governed by law. INSPECTIONS Inspection requests made before 9pm can be scheduled for next business day. By Phone: 386-671-8140, option 3. Permit number and 3-digit inspection code required. By Website: www.codb.us, click ePermits link then Permit Seach to locate permit and schedule. AGREEMENT The Applicant agrees to comply with Municipal Ordinances and with the conditions of this permit; understands that the issuance of the permit creates no legal liability, expressed or implied, of the Department, Municipality, Agency, or Inspector; and certifies that all of the above information is accurate. Signal />^? Date File Copy ~JtL3&jZA. The CITY OF DAYTONA BEACH Permits & Licensing Division - City Hall - Room 127 301 S Ridgewood Ave, Daytona Beach Florida Phone: 386-671-8178 Fax: 386-671-8149 INVOICE Mail To: PO Box 2451 Daytona Beach, FL 32115-2451 ro •&. PERMIT TYPE: FIRE 'ARCEI/lAX ID NO: 25143201120010 PERMIT NO: C1503-083 O) Z ALARM > applicant: Seminole Safety Systems Inc (E March 25,2015 •-* Q) 2461 N Atlantic Av 3 i-h DAYTONA BEACH, FL 32118 GL Account Fee Description Amount Due FIRE FIRE ALARM SYSTEMS 160-322003 104.05 160-322001 120.10 160-341325 10.41 INSPECTION FEES REQUIRED INSPECTIONS MISCELLANEOUS FEES TECHNOLOGY SURCHARGE-FR TOTAL FEES DUE 234.56 PAID MAR 26 2015 Position 3 The City of Daytona Beach Printed: 3/25/2015 by MC1 File Copy > < oSl Permit and T ippnsinp" Division Current Code FFPC 2010 City of Daytona Beach Phone (386) 671-8140 Fax(386) 671-8149 Post Office Box 2451, Daytona Beach, Florida 32115-2451 FIRE PERMIT APPLICATION P££PVED Parcel No. Date _ Job Address Permit No. C (DOJ " C>&3 25143201120010 Job Name Marshalls #228 2461 North Atlantic Ave Owner The TJX ComPanies Address Phone Cjly 770 Cochituate Rd Contractor Seminole Safety Systems, Inc Address 40 Cotillion Ct Contractors License No. Framingham Statc MA Zip /in 01701 Phone 407-830-5330 Fax 407*260-8374 city Casselberry State FL_ zip 32707 EF00QQ018 Email [email protected] Designer Address Improvement Type: 0New •Addition QRcpair ^Renovation [^Replacement OTemporary •Commercial Total Valuation: Type of Work: Parent Permit $15,500.00 0Fire Alarm I [Residential Building Use: Retail I iFire Suppression | lOther Fire Suppression Type: QClean Agent QWet Chemical QSprinkler/Standpipe ^Underground Main* ON/A No. of Sprinkler Heads: No. of Hydrants: Construction Type No. of Pumps: Occupancy Total Sq. Ft. Units Floors Description of Work: New Fire Alarm Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. kAll installations must adhere to the DRC approved site plans. If a water main tap is required, determination of public or private water main is required. Contact the Water Distribution Division at (386) 671-8530 for scheduling of taps to any City owned water main. Print Applicant's Name FAILURE TO COMPLY WITH THE MECHANIC'S Applicant's Signature PAYING TWICE FOR BUILDING IMPROVEMENTS LIEN LAW CAN RESULT IN PROPERTY OWNER INTELLIKNIGHT FIRE ALARM CONTROL PANEL SILENT KNIGHT by Honeywell IntelliKnight® Model 5700 Single Loop Addressable Fire Alarm Control System The affordable addressable fire alarm control panel solution. IntelliKnight Model 5700 is a class leading single loop addressable fire alarm control/communicator system. 5700 provides you with the revolutionary value and performance of addressable sensing technology combined with exclusive, built-in digital communication, distributed intelligent power, that includes an easy to use interface. Powerful features such as drift compensation and maintenance alert are delivered in this powerful FACP from Silent Knight. For more information about the IntelliKnight system, or to locate your nearest source, please call 1-800-328-0103. Description The basic IntelliKnight 5700 system can be enhanced by adding modules such as 5860 remote annunciator, 5824 serial/parallel printer interface module (for printing system reports), and 5496 intelligent power module. 5700 supports SD or SK devices. 5700 also features a powerful built-in dual line fire communicator that allows for reporting of all system activity to a remote monitoring location. Features • Built-in support for up to 50 SK detectors and 50 SK modules creating a total point capacity of 100 points • Built in support for up to 50 SD devices • Up to 125 zones and 125 output groups • Uses standard wire—no shielded or twisted pair required • Built-in digital communicator • Central station reporting by point or by zone • Supports Class B (Style 4) and Class A (Style 6 or 7) configuration for SLC • Drift compensation • 13 pre-programmed output cadences (including ANSI3.41) and 4 programmable outputs • Notification circuits configurable as 1 Class A (Style Z) or 2 Class B (Style Y), or auxiliary power for resettable, constant, or door holder power • Built-in synchronization for AMSECO, Gentex®, Faraday, System Sensor® and Wheelock® appliances • Built-in annunciator with 80-character LCD display • RS-485 bus provides communication to system Model 5700 • Improvements in SKSS deliver five times faster upload/downloads • Built-in RS-232 interface for programming via PC • Built-in Form C trouble relay rated at 2.5A at 27.4 VDC • Programmable date setting for Daylight Saving Time Compatibility The 5700 signal line circuit (SLC) supports multiple device types of the same protocol: SK REVIEWED FOR CODE COMPLIANCE Ycu cannot mix SD aJ$SKSfi($, devices on a FACP. accessories • Upload or download programming, event history, or detector status onsite or from a remote location using a PC and 5660 Silent Knight Software Suite (SKSS) • Two built-in Form C programmable relays rated at 2.5A at 27.4 VDC FILE COPY city ofpmmmiM beach ©iiU14 Honeywell International Inc. INTELLIKNIGHT FIRE ALARM CONTROL PANEL Model 5700 Fire Alarm Control Panel IIU WH«l»H Specifications S-BUS Accessories Electrical Primary AC: 120 VAC, 60 Hz, 1.5A Total Accessory Load: 2.5A @ 27.4 VDC 5860/R Remote Fire Annunciator Notification Power: 2.5A @ 27.4 VDC, power-limited Standby Current: 200 mA Features the same 80 character backlit LCD display keypad and firefighter's key switch as the 5700. The system can be fully programmed and operated from any 5860. 5860 is gray and 5860R is red. Alarm Current: 365 mA Notification/Aux Power Circuits: 2.5A @ 27.4 VDC per circuit, power-limited Battery Charging Capacity: 7.0-35.0 AH Battery Size: 7 AH max. allowed in FACP cabinet. Larger capacity batteries can be 5496 Intelligent Power Module A 6 amp notification power expander that provides four additional power-limited notification appliance circuit outputs. 5880 LED/IO Module 5670 Silent Knight Software Suite End-user facility management software allows viewing of detector status and event history via modem or direct connection. RBB Remote Battery Box Accessory Cabinet. Use if backup batteries are too large to fit into FACP cabinet. Dimensions: 16" Wx 10"Hx6"D (406 mm W x 254 mm H x 152 mm D SK-SCK Seismic Compliance Kit. housed in an RBB accessory cabinet. Features 40 LED outputs, 8 normally open SD505-DTS-K Physical dry contact inputs and one piezo output. Remote test switch that provides remote key Dimensions: 5865-3 and 5865-4 12.75" Wx 15.2" Hx 3.4" D Remote LED Annunciator (32.39 W x 38.42 H x 8.57 D cm) Features 30 Programmable LED (15 red and 15 yellow) outputs and a piezo sounder. The Weight: 11.5 lbs. (5.2 kg) 5865-4 adds a silence and reset switch to Color: Red the package. Telephone Requirements: FCC Part 15 and Part 68 approved Type of Jack: RJ31X (two required) 5883 Relay Board Features 10 general purpose Form C relays. Listings 5824 Serial/Parallel Printer NFPA 13, NFPA 15, NFPA 16, NFPA70, & NFPA 72: Central Station; Remote Interface Module Provides one parallel and one RS-232 serial port for connecting a printer to 5808. Use to print a real-time log of system events, detector status reports, and event history. Interfaces with building control system. Signalling; Local Protective Signalling Systems; Auxiliary Protected Premises Unit; & Water Deluge Releasing Service. Suitable for automatic, manual, waterflow, sprinkler supervisory (DACT non-coded) signalling Used with 5880 module. services. Miscellaneous Accessories Other Approvals: UL Listed; 5660 Silent Knight Software Suite CSFM 7170-0559: 144; MEA429-92-E Vol. XVI; OSHPD (CA) OSP-0065-10 SILENT operated test function and annunciation of detector alarm with SD505-DUCTR. SP-TR Small panel trim ring. Use to flush mount the panel. 16.975" H x 14.630" W. SD and SK Devices See the data sheets listed below for a complete listing of the SD and SK devices. 53624 SD Devices data sheet 53623 SK Devices data sheet User-friendly Windows software for remote programming of 5700s using a PC. Upload and view panel account information, event history, and detector status. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all KNIGHT specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, by Honeywell Fax: (203) 484-7118. For Technical Support, Please call 800-446-6444. www.silentknight.com Assembled In America FIRE SYSTEM ACCESSORY T 5496 Intelligent SILENT KNIGHT by Honeywell Power Module A dynamic combination of power and intelligence for your notification expansion needs. The Model 5496 Intelligent Power Module by Silent Knight is the most-powerful and cost-effective power supply available today. It delivers 6 amps of notification appliance circuit power and built-in synchronization for appliances from System Sensor®, Gentex®, Faraday, AMSECO and Wheelock® —what you need to drive power-hungry components like ADA notification appliances. The 5496's advanced microprocessor design is years ahead ofthe competition. Its switch mode power supply design is up to 50% more efficient than competitive linear mode power supplies. For the most sophisticated and cost-effective notification power supply available, you need Model 5496. Call Silent Knight today for more information at 1-800-328-0103. power Model 5496 Intelligent Power Module The model 5496 is a 6 amp notification power expander that provides its own AC power connection, battery charging circuit, and backup battery for use with fire and security controls such as the IntelliKnight Model 5808 Fire Control /Communicator. The 5496 is the cost- effective solution for powering notification appliances required by the Americans with Disabilities Act (ADA). The 5496 has built-in ANSI cadence pattern, which can upgrade older control panels that lack cadence capability. The Output circuits can be programmed as Notification Appliance Circuits, or as Auxiliary Power (configurable for, constant, resettable, or door holder power). Features • UL Listed for 6 amps of notification power • Power supply's advanced switch mode design reduces damaging heat and manages power up to 50% more efficiently than other systems • Built-in synchronization for appliances from AMSECO, Gentex®, Faraday, System Sensor®, and Wheelock® • 3 amps per output circuit • Ground fault detector • Communicates to the FACP via 4- wire SBUS (wire runs up to 6000 ft) • AC loss delay option shuts off power to non-essential high-current accessories like magnetic door holders • Lightweight design adds to ease of installation and reduces shipping costs • UL 864,1481 & 1971 listed • ANSI Cadence pattern output capability built-in Specifications AC Input: 120 VAC at 2.7 A Current: Standby 40 mA 32° to 120° F(0°to49°C) Dimensions: Notiflcation/Aux.Power circuits: 4 Output configuration: - 2 Class A (Style Z) - 4 Class B (Style Y) (1 Class A & 2 Class B) Amps per output circuit: 3.0 (6.0 amps total) Notification circuit output: • Four power-limited notification outputs; 2 Class A or 4 Class B, or 1 20.4 to 27.3 VDC, 3.0 amps each, 4.7k EOL resistor required on each Class A and 2 Class B Ambient Temp.: Alarm 160 mA • 24 VDC filtered output voltage • NACs are programmable as Notification Appliance Circuits, or as auxiliary power to be used as constant, resettable, or door holder 5496 Intelligent Power Module Output: 24 VDC at 6 amps Class B circuit Battery charging capacity: 35.0 AH 12.25" Wx 16" Hx3"D (30.88 Wx 40.64 H x7.62 D cm) Listings: UL CSFM MEA 429-92-E vol. XIV Compatible FACPs • • • • IntelliKnight 5700 IntelliKnight 5808 IntelliKnight 5820XL IntelliKnight 5820XL-EVS FIRE SYSTEM ACCESSORY Firepower 5496 Distributed Power Module Engineering Specifications The contractor shall supply a power module compatible with the Silent Knight FACP. The power module must have 6.0 amps of output power. The power module shall connect to the main FACP via an RS 485 system bus (SBUS). The Outputs shall be programmable as Notification Appliance Circuits, or as Auxiliary Power (configurable for, constant, resettable, or door holder power). The power module shall have four separate outputs. The power module RS 485 bus shall be optically isolated providing ground loop isolation and transient protection. 4 Outputs Programmable as Notification Appliance Circuits, or as Auxiliary Power SBUS Communication Output 1 To a Compatible Silent Knight FACP Output 2 Output 3 Output 4 Auxiliary Power Can Be Programmed To Be Constant, Resettable, or Door Holder Power This document is not intended to be used for installation purposes. We try SILENT to keep our product information up-to-date and accurate. We cannot cover KNIGHT all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact by Honeywel Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. For Technical Support, Please call 800-446-6444. www.silentknight.com MADE IN AMERICA FORM# 350387 Rev E @2Q1 g Honeywel| international Inc. INTELLIKNIGHT ACCESSORY SILENT KNIGHT by Honeywell 5860 Remote Annunciator Bring the power to control an IntelliKnight fire alarm control panel to every area within your facility Now you can operate and program your IntelliKnight system from up to twelve locations throughout your facility. The 5860 remote annunciator provides the same advanced, easy-to-use interface found on the IntelliKnight panel's built-in annunciator. The 80-character display and ergonomically designed keypad allow for simple and error-free system operation. All operations—including reset, silence, detector status checking, fire drill, and programming—are identical. Access to the system is through a firefighter's key or an access code. For security, a special installation code is needed for programming functions. The 5860 connects to the IntelliKnight panel via the RS-485 system bus. Wire runs can be up to 6000 feet from the panel. For more information about the IntelliKnight system, or to locate your nearest source, please call 1-800-328-0103. Description Features include an 80-character backlit LCD providing easy-tounderstand system messages. The annunciator is ergonomically designed with over-sized buttons for the most frequently used features, like Reset and Silence. In addition to status messages displayed on the LCD, there are five LEDs for alarm, supervisory, trouble, silence, and AC power status. The annunciator is available in gray to match virtually any decor and red for applications where the annunciator must stand out. The annunciator enclosure can be surface or flush mounted. A trim ring kit is available for surface mounting. • Available in red or light gray • Support for simultaneous use of multiple 5860s • RS-485 interface to panel • Operation and appearance is identical to 5860 built-in annunciator • On-board piezo sounder audibly indicates alarms, troubles, and supervisories • Five status LEDs for alarm, supervisory, trouble, silence and AC power conditions • Wiring lengths up to 6000 ft. from the FACP (depending on wire gauge and number of devices on SBUS) • UL listed, complies with NFPA 72 • CSFM approved Electrical Specifications Operating Voltage: 24 VDC Standby Current: 20 mA max Features Alarm Current: 25 mA • 80-character backlit LCD display (4 lines with 20 characters on each line) Wiring Distance: 6,000 max. from FACP (depending on wire gauge • Tactile and audible feedback SBUS) • Accepts user codes or fire fighter's key • Larger keypad buttons for system reset and silence • Install up to twelve 5860s per 5820XL/EVS or 5808 system • Install up to eight 5860s per 5700 system and number of devices on the Mechanical Specifications Physical 9.1" W x 7.4" H x 1.5" D (23.1 Wx 18.8 Hx 3.8 D cm) 5860 Environmental Operating Temperature: 32°F 120°F(0°C-49°C) Humidity: 10% - 93% noncondensing Compatibility The 5860 is compatible with the following FACP's: • 5820XL Addressable Fire Control Panel • 5820XL-EVS Fire Control Panel with Emergency Voice System • 5808 Addressable Fire Control Panel • 5700 Addressable Fire Control Panel Shipping Weight: 2.8 lbs (1.3 kg) Color 5860R: Red 5860: Gray PN 350224 Rev G © 2014 Honeywell International Inc INJELLiKNIGHT ACCESSORY 5860 Remote Annunciator Engineering Specifications The main control must have a built-in annunciator and must support up to 12 remote annunciators. Remote annunciators shall have the same control and display layout so as to match the appearance of the built-in annunciator. Remote annunciators shall be available in two colors, red or light gray. Remote annunciators shall have identical functionality and operation as the built-in annunciator. All annunciators must have an 80-character LCD display and must feature five LEDs for: General Alarm, Supervisory, System Trouble, System Silence, and System Power. All controls and programming keys are silicone mechanical type with tactile and audible feedback. Keys have a travel of .040 inches. No membrane style buttons will be permissible. The annunciator must be able to silence and reset alarms through the use of a code entered on the annunciator keypad or by using a firefighter's key. The annunciator must have two levels of user codes that will limit the operating system programming to authorized individuals. The control panel must allow all annunciators to accommodate multiple user input simultaneously. Wire Runs Up to 6000 Feet From FACP 5860 5860 • Up to 12 5860s Per IFP-100/ECS or IFP-1000/ECS System • Up to Eight 5860s Per 5700 System Compatible IntelliKnight FACP Listings Ordering Information NFPA 72; UL Listed; CSFM 7170-0559: 135; MEA429-92-E Vol. IX; 5860R Remote Annunicator four line LCD annunciator with 20 characters per line. Red FM Approved 5860 Remote Annunciator four line LCD annunciator with 20 characters per line. Gray Accessories 5860TR Red Trim Ring for surface mounting 5860TG Gray Trim Ring for surface mounting This document is not intended to be used for installation purposes. We try to SILENT keep our product information up-to-date and accurate. We cannot cover all KNIGHT by Honeywell specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610. Phone: (800) 328-0103, Fax: (203) 484-7118. For Technical Support, Please call 800-446-6444. www.silentknight.com Assembled in America INTELLIKNIGHT ACCESSORY SD500-PS and SD500-PSDA Addressable Pull-Station IntelliKnight's addressable pull stations combine fast response with pin-point location ID. The SD500-PS and SD500-PSDA are a single action or dual action addressable manual fire alarm pull station for use with Silent Knight's IntelliKnight fire control panel. Extremely easy to operate, the SD500-PS/PSDA provides a fast and practical means of manually initiating a fire alarm signal. The IntelliKnight panel recognizes each manual pull station by its specific address saving precious seconds in determining the location of an alarm. The SD500-PS/PSDA mounts to a single gang box and features a rugged metal construction that lasts and lasts. Combine all this with the features you've come to expect from Silent Knight - easy installation and stable operation - and it adds up to a flexible solution for all your fire protection needs. Model SD500-PS & • Extremely easy to operate SD500-PSDA • Corrosion-resistant gold-plated Addressable Pull Station The SD500-PS is a single action addressable fire pull station, and the SD500--PSDA is a dual action addressable fire pull station. The SD500-PS/PSDA feature rugged metal construction A terminal strip on back of the pull station allows interconnection of the pull station to the SLC of an IntelliKnight control panel. The SD500-PS/PSDA is designed for indoor use in nonexplosive environments. The normally open initiating point contacts are gold-plated to avoid risk of corrosion. The SD500- PS/PSDA has been tested by UL for compliance to the requirements contacts. • Reflective label makes it easier 4 PULL 4 to locate in low light Operation The SD500-PS/PSDA single action pull stations are operated by a pull on the front pull cover of the station. A plunger switch, wired to > a self contained addressable module, is released as the pull station opens to initiate the alarm. Once operated, the cover hangs down and can be seen up to 100 feet away. The pull station is reset by returning the front cover to the normal upright position and relocking the station with a reset key. The reset keys are the same keys used on Silent Knight Bfv FIRE ) ALARM 1$ KNIGHT enclosures. of the Americans with Disabilities The SD500-PS/PSDA includes a ACT (ADA). status LED which blinks, indicating Features that the addressable module is Ambient Temperature: communicating with the loop. The status LED lights continuously during an alarm. A dip switch on Mounting: • UL Listed • CSFM listed • ADA compliant • Key reset (Same key as Silent Knight enclosures) • Surface mount back box available • Terminals - accept up to 14 gauge wire the addressable module is used to SD500-PS 32°F to 120°F (0°C to 49°C) Single gang box - Optional Red Surface Mount Box PS-SMBB set the unique address. Specifications Operating Voltage: 24VDC Standby Current: .55mA Alarm Current: .55mA SILENT KNIGHT INTELLIKNIGHT ACCESSORY SD500-PS and SD500-PSDA Addressable Pull-Station Engineering Specifications Manual pull station shall be addressable Module SD500-PS/SD500-PSDA. Equipment shall be made of 14 gauge C.R.S.(Cold Rolled Steel), painted with a red enamel . The label shall contain the words Fire Alarm and be made of a reflective material embossed text 3/8 inches tall. Operating instruction shall be clearly visible on the same label. Manual station Shall contain a key operated test and reset lock using a lock plate actuator, the key shall match the control panel. Manual station shall contain four terminal blocks with two connected to the addressable module and two connect to the SLC loop. Manual station shall provide data to the control panel with an ID address programmed by dip switch settings . Manual stations shall be Underwriters Laboratories Inc. listed and installed within the limits defined in the American Disabilities Act. FACP - *. Wiring H h Mounting to Optional Mounting to Single Gang Electrical Box Surface Mount Box SD500-PSDA Installing SD500-LK Electrical Box must be atieail 1-112" Deep Dimensions SILENT KNIGHT 7550 Meridian Circle, Maple Grove, MN 55369-4927 800-446-6444 or in Minnesota 763-493-6435 MADE IN AMERICA FORM# 350342, Rev. 09/03 FAX: 763-493-6475 World Wide Web: http://www.silentknight.com Copyright © 2003 Silent Knight INTELLIKNIGHT ACCESSORY SILENT SD500-AIM & SD500-MIM KNIGHT Addressable Input Modules by Honeywell IntelliKnight's addressable contact monitor modules combine fast response with pinpoint location ID. A combination that saves lives and property. The SD500-AIM and SD500-MIM are addressable input modules for use with Silent Knight IntelliKnight fire alarm control panels (FACP). The SD500-AIM and SD500-MIM are designed to be used with pull stations, water flow switches, and other applications requiring dry contact alarm initiation devices. The SD500-AIM addressable input module mounts to a 4"-square box. The SD500-MIM mini input module fits inside a single gang box. The modules are supervised, single input contact monitors. Using an EOL resister, they monitor for alarm contact closures and for open circuit wiring fault conditions. The SD500-AIM and SD500-MIM offer a compact design for adaptability and pleasing aesthetics as well as easy installation and stable operation—a flexible solution for all your fire protection needs. For more information about the IntelliKnight system, or to locate your nearest source, please call 1-800-328-0103. Description The SD500-AIM and SD500-MIM are addressable input modules for use with the Intelliknight fire alarm control panels (FACPs). The SD500-AIM addressable input module mounts to a 4"-square box. The SD500-MIM mini input module fits inside a single gang box. Both input modules are designed to be used with pull stations, water flow switches, and other applications requiring dry contact alarm initiation • DIP switch programmable for fast installation • Up to 2500 ft wiring distance from either input module to contact • Use up to 14 gauge wire • UL listed Electrical Specifications Standby Current: 0.55 mA Alarm Current: 23 mA max for one device; 46 mA max for two devices; 0.55 mA for each additional device devices. These modules are supervised, single input contact monitors. Using an EOL resistor, they monitor for alarm contact closures and for open circuit wiring Line Resistance: 50z max Mechanical Specifications SD500-AIM Physical Description Dimensions: fault conditions. If a fault occurs in the 4.9" Wx 4.9" Hx1" D wiring, the module alerts the FACP. Each addressable input module is programmed with a unique signal line circuit (SLC) loop address. (12.4 Wx 12.4 Hx 2.5 D cm) Weight: 3.6 oz (120.1 g) Color: Ivory cover plate SD500-MIM Physical Description Features Dimensions: • Single contact monitor 1.5"Wx2.5"Hx0.7"D • SD500-AIM supports Class A (Style D) or Class B (Style B) contact monitor wiring • SD500-MIM support for Class B (Style B) contact monitor wiring • Attractive ivory cover plate with the SD500-AIM • Small and lightweight size allows for flexible mounting options with the SD500-MIM (3.8 Wx6.4Hx1.8Dcm) Weight: 1.6 oz (45.4 g) Environmental Operating Temperature: 32oF-120°F(0°C-49oC) Humidity: 10% - 93% non-condensing SD500-MIM Approvals NFPA 71 & NFPA 72 UL864 CSFM 7300-0559: 132 MEA 429-92-E Vol. IX FM Approved for use with the 5820XL INTELLIKNIGHT ACCESSORY SD500-AIM & SD500-MIM Addressable Input Modules Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable input modules Silent Knight SD500-AIM or SD500-MIM. The modules shall be UL listed and compatible with Silent Knight's IntelliKnight FACPs. The SD500-MIM shall fit inside a single gang electrical box. The SD500-AIM shall be supplied with a plastic cover and shall be suitable for mounting to a 4"-square or double gang electrical box. The SD500-AIM addressable input module must provide a monitor LED that is visible from outside the cover plate Compatible FACPs Ordering Information 5820XL SD500-AIM Input Module Addressable input module with ivory cover plate. 5820XL-EVS 5808 SD500-MIM Input Module Addressable mini input module. 5700 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all KNIGHT specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight by Honeywell 12 Clintonville Road, Northford, CT 06472-1610.Phone: (800) 328-0103 Fax: (763) 493-6475 For Technical Support, Please call 800-446-6444. .www.silentknight.com SILENT MADE IN AMERICA FORM# 350231 Rev. F ©2013 Honeywell International Inc INTELLIKNIGHT ACCESSORY Model SD505-DUCTR SILENT KNIGHT and SD505-DTS-K by Honeywell Detect smoke in air handling systems and prevent re-circulation with Silent Knight's addressable duct smoke detector The SD505-DUCTR addressable duct smoke detector detects smoke and products of combustion present in air moving through an HVAC air handling system. The SD505-DUCTR is a heavy duty metal housing with a pre-installed SD505-APS photoelectric smoke detector and relay module. When smoke is detected in a duct, the unit communicates the condition to the IntelliKnight control panel. The panel, in turn, depending on programming and wiring, turns off fans, blowers, and other devices. Now there's even more power and flexibility available to the IntelliKnight family of products. For more information on this product or to locate your nearest source, please call 800-328-0103. Model SD505-DUCTR Analog Duct Smoke Detector with Relay Module The Model SD505-DUCTR Addressable Duct Smoke Detector with Relay provides early detection of smoke and products of combustion present in air moving through an HVAC duct to prevent re-circulation of smoke into the air Features Two-wire connection to SLC Detects and limits spread of smoke LED alarm indication and communication on sensor head Rugged steel backbox with clear plastic cover Installation template included No screens or filters to clean Detector pre-installed handling system. The SD505DUCTR is a heavy duty metal housing with a pre-installed SD505-APS Analog Photo Electric Smoke Sensor and relay module. 3 standard tube lengths When smoke is detected in a duct, FM Approved the unit communicates the condition to the IntelliKnight FACP. The built-in relay module, in turn, UL listed, complies with NFPA 72 and 101 CSFM listed MEA Approved 429-92-E, Vol 9 Specifications Physical turns off fans, blowers, and other Dimensions: 2Va H x 9" L x VAT W devices. Weight: 3lbs Operation Air sampling is accomplished by two tubes which protrude into the duct. An exhaust tube of one standard length (7.5") is provided with the detector housing. Intake sampling tubes (ordered separately) are supplied in three standard lengths. Duct mounting is accomplished through a template and 4 sheet metal screws (provided). SD505-DUCTR SD505-APS Photoelectric Smoke Electrical Operating Voltage: 24 VDC Alarm Relay Contact rating: 10A@24VDC;10A@ 115 VAC; 10A@240 VAC Trouble Relay Contact Rating: 2.5A @ 30 VDC Aux. Power Input Current: 20mA Standby, 62 mA Alarm SLC Input Current: 0.5 mA Max. SLS resistance: 50 Ohms SD505-DTS-K Environmental Operating Temp: 32°F to 100°F (0°C to 37°C) Humidity: 10%-85% non-condensing Other Ratings: Air Velocity 300 - 4000 ft/min Sampling Tubes: SD505-T2 2.5ft sampling tube SD505-T5 5ft sampling tube SD505-T10 10ft sampling tube IHTELtlKNIGHT ACCESSORY Model SD505-DUCTR and SD505-DTS-K Duct Smoke Detector with Relay and Remote Test Switch Engineering Specifications The air duct smoke detector shall be Silent Knight Model SD505-DUCTR and remote test switch shall be SD505-DTS-K. The housing shall contain a Silent Knight model SD505-APS, Photoelectric Smoke Sensor. The duct detector shall be of metal construction. Complete mechanical installation must be able to be performed without removal of the detector cover. Terminal connections shall be screw type using a minimum of #6 screw. FACP/5815XL Connection Class A (Style 6) FACP/5815XL Connection DTS-K connection .in re;— nil Class B (Style 4) This document is not intended to be used for installation purposes. We try to SILENT keep our product information up-to-date and accurate. We cannot cover all KNIGHT specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight by Honeywell Zl i« . •„ r? _. li _«_« j --r nr,7o 4„„ nu /onn\ ooo rv-ino 12 Clintonville Road. Northford, CT 06472-1610 Phone:(800)328-0103, Fax: (203) 484-7118. www.silentknight.com MADE IN AMERICA . FORM# 350005 Rev B ' rniTu""~~Iii iZ*«Z,~t;r.n«i !„,- Copynght © 2011 Honeywell International Inc. yy INTELLIKNIGHT ACCESSORY SILENT KNIGHT Addressable Photoelectric Smoke Detector by Honeywell Detect smoldering fires quickly and get help fast with IntelliKnight® photoelectric smoke detectors. IntelliKnight addressable photoelectric smoke detectors are the clear choice for commercial settings where smoldering fires are a threat. In addition to accurately detecting a smoldering fire, each SD505-APS photoelectric detector has a unique address, which is recognized by the IntelliKnight panel. No precious seconds are wasted in determining location of an alarm. The SD505-APS compensates automatically for contamination in the environment. And detector testing is simple—even from a remote site. Like other IntelliKnight detector models, the SD505-APS offers a low profile for pleasing aesthetics. The IntelliKnight family of detectors has been designed to use a common base, Model SD505-6AB, allowing complete application and placement flexibility. Combine all this with the features you've come to expect from Silent Knight smoke detectors—easy installation, stable operation, RF/transient protection, and vandal-resistant locking—and it adds up to a flexible solution for all your fire protection needs. Model SD505-APS Analog / Addressable Photoelectric Type Smoke Detector The SD505-APS is particularly suited to detecting dense smoke typical of fires involving materials such as soft furnishings, plastic, foam or other similar materials which tend to smolder and produce large visible particles. approximately every 15 seconds, indicating that the head is communicating with the loop. The LED lights continuously during the alarm period. Features • Low profile, 2 inches, including without mechanical switches The detector features automatic Operation The SD505-APS units made up of an LED light source and a silicon photo diode receiving element. In a normal standby condition, the receiving element receives no light from the pulsing light source. In the event or fire, smoke enters the detector and light is reflected from the smoke particles to the receiving element. The light received is converted into an electronic signal. Under normal conditions, the status LED blinks ••••• • Simple and reliable addressing • Automatic compensation for compensation for contamination and a simple detector calibration test procedure that can be run from the panel or remotely (using the Windows™ based downloading software). • base sensor contamination • Built-in fire test feature • Simple detector calibration testing through the control panel or remotely through a Windows™ based computer SD505-APS Smoke Detector Specifications Operating Voltage: Current Consumption Standby: .55 mA Alarm: .55 mA Ambient Temperature :32°Fto 120°F software. • Vandal-resistance locking features • (0°C to 49°C) Mounting: Field cleanable • UL listed, meets NFPA 72 Ch 7 requirements • CSFM approved • MEA approved • FM Approved 17-41 VDC 4" Square, 4" OCT, Single gang mud ring Relative Humidity: 85% noncondensing Air Velocity: 0 - 300 FPM Compatible Bases: (Sold Separately) SD505-6AB SD505-6IB SD505-6RB SD505-6SB TNTELLIKNIGHT ACCESSORY Model SD505-APS Addressable Photoelectric Smoke Detector Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable photoelectric smoke detector Silent Knight SD505-APS. The combination detector head, and twist-lock base, shall be UL® listed compatible with Silent Knight's IntelliKnight fire control panels. The base shall permit direct interchange with Silent Knight SD505-AIS Ionization Smoke Detector, or SD505AHS Heat Detector. Base shall be the appropriate twist-lock base SD505-6AB. The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady. The detector may be reset by actuating the control panel reset switch. The calibration of the detector shall be capable of being selected and measured by the control panel without the need for external test apparatus. The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field selectable as required. The SD505-APS shall automatically perform a functional test of the detector. The test method shall simulate effects of products of combustion in the chamber to ensure testing of detector circuits. Diameter = 5-15/16" Diameter = 3-15/16" Height = 2 inches, including base Model SD505-6AB Detector Base Model SD505-APS Detector Head (front view) (front view) SILENT This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover KNIGHT all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent by Honeywell Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. www.silentknight.com MADE IN AMERICA FORM# 350225 Rev D ©2010 Honeywell International Inc. HN Series Effective October 2014 Technical Data TD001017EN Supersedes May 2013 HS Series ST Series Exceder Strobe, Horn Strobe, and Horn Notification Appliances Description The Wheelock Exceder Series of notification appliances feature a sleek modern design that will please building owners with reduced total cost of ownership. Installers will benefit from its comprehensive feature list, including the most candela options in one appliance, low current draw, no tools needed for setting changes, voltage test points, 12/24 VDCoperation, universal mounting base and multiple mounting options for both new and retrofit construction. The Wheelock Exceder Series incorporates high reliability and high efficiency optics to minimize current draw allowing for a greater number of appliances on the notification appliance circuit. All strobe models feature an industry first of 8 candela settings on a single appliance. Models with an audible feature 3 sound settings (90, 95, 99 dB). All switches to change settings, can be set without the use of a tool and are located behind the appliance to prevent tampering. Wall models feature voltage test points to take readings with a voltage meter for troubleshooting and AHJ inspection. The Wheelock Exceder Series of wall and ceiling notification appliances feature a Universal Mounting Base (UMB) designed to simplify the installation and testing of horns, strobes, and combination horn strobes. The separate universal mounting base can be pre-wired to allow full testing of circuit wiring before the appliance is installed and the surface is finished. It comes complete with a Contact Cover for protection against dirt, dust, paint and damage to the contacts. The Contact Cover also acts as a shunting device to allow pre-wire testing for common wiring issues. The Contact Cover is polarized to prevent it from being installed incorrectly and prevents the appliance from being installed while it is on the UMB. When the Contact Cover is removed the circuit will show an open until the appliance is installed. The UMB allows for consistent installation and easy replacement of appliances if required. Wall models provide an optional locking screw for extra secure installation, while the ceiling models provide a captivated screw to prevent the screw from falling during installation. F:T« Powering Business Worldwide Technical Data TD001017EN HN Series Effective October 2014 HS Series ST Series • Environmentally friendly Features • • Sleek modern aesthetics Low current draw • Up to 9 models now in 1 appliance draw© • Finger slide switches • 12/24VDC on a single appliance • Voltage test points • Easy to remember model numbers • Multiple voltages © Patented • 3 Audible settings Note: All CAUTIONS and WARNINGS are identified by the symbol A. All . 90, 95, 99 dB warnings are printed in bold capital letters. • Industry leading—8 candela settings on 1 device • Wall: 15/1575/30/75/95/110/135/185 . Ceiling: 15/30/60/75/95/115/150/177 A WARNING PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT.VISIT WWW.C00PERN0TIFICATI0N.COM OR CONTACT COOPER NOTIFICATION FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURETO COMPLY WITH ANY OFTHESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OFTHESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes • Strobes are designed to flash at 1 flash per second minimum over their "Regulated Voltage Range'.' • All candela ratings represent minimum effective strobe intensity based on UL Standard 1971. • Series Exceder Strobe products are Listed under UL Standards 1971 and 464 for indoor use with a temperature range of 32°F to 120°F (0°C to 49°C) and maximum humidity of 93% (± 2%) UL Universal mouting base - Ceiling and wall 464(85% UL 1971). • Mounts to 5 backbox types: 1 gang, 2 gang, 4" square, 3.5" octal. &4" octal. (100mm for international customers) Universal mounting base • Series Exceder horns are under UL Standard 464 for audible signal appliances (Indoor use only). Contact cover Compatibility and requirements • Synchronize using the Wheelock® Sync Modules or panels with built-in Wheelock3 Patented Sync Protocol • Compatible with UL "Regulated Voltage" using filtered VDC or unfiltered VRMS input voltage • Strobes produce 1 flash per second over the "Regulated Voltage" range Common base for wall and ceiling with 5 mounting options Voltage test points for quick troubleshooting and easy spot checking (wall models only) Compliance • • ADA/NFPA/ANSI/OSHA • EATON www.eaton.com UL 1971, UL 464, ULC, CSFM, FM RoHS Technical Data TD001017EN HN Series HS Series Effective October 2014 ST Series Table 1. Strobe Ratings per UL Standard 1971 UL Max Current© 12 VDC 24 VDC/24 FWR Regulated Voltage Model Range VDC 15 15/75 30 ST 8.0-33.0 0.057 0.070 0.085 STC 8.0-33.0 0.061 60 — 0.103 0.08b — 75 95 110 0.135 0.163 0.182 0.135 0.163 115 0.205 0.182 — 135 — 177 150 — 0.253 0.205 — 185 15 15/75 0.253 0.110 0.140 — 0.110 — — Table 2. Horn Strobe Ratings per UL 1971 & Anechoic at 24 VDC UL Max Current© at Anechoic 99 dBA 24 VDC Regulated Voltage Range VDC 15 15/75 30 HS 8.0-33.0 0.082 0.095 0.102 HSC 8.0-33.0 0.082 Model 60 — 0.102 — 0.141 75 95 110 0.148 0.176 0.197 0.148 0.176 115 0.197 — 135 0.242 — 150 177 — — 0.242 — 0.282 185 15 15/75 0.282 0.125 0.159 0.125 — — UL Max Current© at Anechoic 95 dBA Regulated Voltage Model Range VDC 15 15/75 30 HS 8.0-33.0 0.073 0.083 0.087 HSC 8.0-33.0 0.073 — 60 — 0.087 0.128 75 95 no 0.139 0.163 0.186 0.139 0.163 115 — 0.186 — 150 135 0.230 — 0.230 — 185 15 15/75 0.282 0.122 0.153 177 — 0.272 — 0.122 — UL Max Current© at Anechoic 90 dBA 12 VDC 24 VDC Regulated Voltage Model Range VDC 15 15/75 30 HS 8.0-33.0 0.065 0.075 0.084 HSC 8.0-33.0 0.065 — 60 — 0.084 0.120 75 95 110 0.136 0.157 0.184 0.136 0.157 115 — 0.184 — 135 0.226 — 150 177 — — 0.267 0.226 185 15 15/75 0.267 0.120 0.148 0.120 — — © UL max current rating is themaximum RMS current within thelisted voltage range (16-33 VDC for 24VDC units). For strobes theUL max current is usually at theminimum listed voltage (16 VDC for 24 VDC units). For audibles the max current is usually at the maximum listed voltage (33 VDC for 24VDC units). For unfiltered ratings, see installation instructions. Model Legend Table 3. Horn Ratings per UL Anechoic Regulated Voltage Model Range VDC 99 dB 95 dB 90 dB HN = Horn R 0.022 ST = Strobe A 0.022 HS = Horn Strobe AL = Alert Lettering (strobes only) = Ceiling Mount N = No Lettering (strobesonly) = HN 16-33.0 0.064 0.044 HNC 16-33.0 0.084 0.044 HN 8.0-17.5 0.047 0.026 0.017 C HNC 8.0-17.5 0.047 0.026 0.017 W Sync w/ DSM or Strobe Candela Red White Example 1: STRC = Strobe, Red, Ceiling Mount Example 2: HSR = Horn Strobe, Red,Wall Mount Example 3: HSW= Horn Strobe, White, Wall Mount Table 4. Specification & Ordering Information Model = = Agent Lettering (strobes only) Wheelock Power 12/24 Supplies VDCG Options Mounting Example 4: STW-AL = Strobe,White, Wall Mount, AlertLettering Horn Strobes HSR 15/1575/30/75/95/110/135/185 X X UMB® HSW 15/1575/30/75/95/110/135/185 X X HSRC 15/30/60/75/95/115/150/177 X X HSWC 15/30/60/75/95/115/150/177 X X UMB® UMB® UMB® Strobes STR 15/1575/30/75/95/110/135/185 X X STW 15/1575/30/75/95/110/135/185 X X STRC 15/30/60/75/95/115/150/177 X X STWC 15/30/60/75/95/115/150/177 X X HNR X X HNW X X HNRC X X HNWC X X UMB® UMB® UMB® UMB® Horn UMB® UMB® UMB® UMB® Example: HSR Example: HSWC © 12VDC models feature15 &15/75settings © UMB = Universal Mounting Base EATON www.eaton.com HN Series HS Series ST Series Technical Data TD001017EN Effective October 2014 Architects and Engineers Specifications The notification appliances shall be Wheelock Exceder Series HS Audible Strobe appliances. Series ST Visual Strobe appliances and Series HN Audible appliances or approved equals. The Series HS and ST Strobes shall be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired) for Indoor Fire Protection Service. The Series HS and HN Audibles shall be UL Listed under Standard 464 (Fire Protective Signaling}. All Series shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP) with the ability to operate from 8 to 33 VDC. Indoor wall models shall incorporate voltage test points for easy voltage inspection. The Series HS Audible Strobe and ST Strobe appliances shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. The Series shall be of low current design. Where multicandela appliances are specified, the strobe intensity shall have 8 field selectable settings at 15, 15/75, 30, 75, 95, 110, 135, 185 candela for wall mount and 15, 30, 60, 75, 95, 115, 150, 177 candela for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 15/75 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g., ADA compliance). Appliances with candela settings shall show the candela selection in a visible location at all times when installed. The audible shall have a minimum of three (3) field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3) audible outputs. The Series HS Audible Strobe, ST Strobe and Series HN Audible shall incorporate a patented Universal Mounting Base that shall allow mounting to a single-gang, double-gang, 4-inch square, 3.5-inch octal, 4-inch octal or 100mm European type back boxes. Two wire appliance wiring shall be capable of directly connecting to the mounting base. Continuity checking of the entire NAC circuit prior to attaching any notification appliances shall be allowed. Product shall come with Contact Cover to protect contact springs. Removal of an appliance shall result in a supervision fault condition by the Fire Alarm Control Panel (FACP). The mounting base shall be the same base among all horn, strobe, horn strobe, wall and ceiling models. All notification appliances shall be backwards compatible. The Series HS and ST wall models shall have a low profile measuring 5.24" H x 4.58" W x 2.19" D. Series HN wall shall measure 5.24" H x 4.58" W x 1.6" D. The Series HSC and STC shall been round and have a low profile with a diameter of 6.68" x 2.63" D. Series HNC ceiling shall have a diameter of 6.68" x 1.50" D. When synchronization is required, the appliance shall be compatible with Wheelock's DSM Sync Modules, Wheelock Power Supplies or other manufacturer's panels with built-in Wheelock Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync protocol fails to operate, the strobe shall revert to a non-synchronized flash-rate and still maintain (1) flash per second over its Regulated Voltage Range. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock synchronization protocol. Wall Appliances: UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM, RoHS Ceiling Appliances: UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM, RoHS Note: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc., dba Cooper Notification standard terms and conditions. WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Eaton 1000 Eaton Boulevard Cleveland. OH 44122 United States Eaton.com Eaton Cooper Notification 273 Branchport Ave. Long Branch, NJ 07740 CooperNotification.com © 2014 Eaton All Rights Reserved Printed in USA Publication No.TD001017EN Powering BusinessWorldwide October 2014 Eaton is a registered trademark. All other trademarks are property of their respective owners. ELK Sealed Lead Acid Battery Two-Year Warranty ELK Sealed Lead Acid Batteries are excellent for the following applications with regard to size, amp hour rating, and proper terminal connections: battery backup (for access control systems, fire alarm systems, and security alarm systems), electrically motorized vehicles, emergency lights, lighted exit signs, and uninterruptible power supplies. 12V, 8 Ah ELK-1280 SPECIFICATIONS: TO \ Nominal Voltage 12 Volts Rated Capacity 8 Ah (20 hour rate) Length 5.94" (151 mm) Width 2.56" (65 mm) Height 3.98" (101 mm) Weight (Approximate) 5.6 lbs (2.5 kg) Terminals F1 FastonTab(.187") UL Recognized Component 97% Recyclable ELECTRICAL SPECIFICATIONS: Capacity ' 20 hour rate (0.375A) 10 hour rate (0.71 A) 5 hour rate (1.27A) 1 hour rate (4.5A) 77T(25°C) Dimensions(mm) 8Ah Fl 7.1Ah 4 n 6.37Ah ...< 4.5Ah e Capacity affected by Temperature 104°F(40°C) 77"F (25"C) 32*F(0°C) 5°F(-15°C) (20 hour rate) 102% 100% j^ 85% T : 65% Cycle: Initial Charging Current less than 2.25A Voltage 14.4V -15.0V at 770F(25"C) Standby: Voltage 13.5V -13.8V at 77°F(25°C) Charge Constant Voltage DischargeCharacteristics (2()T, 68*F) \ no \ \ \ , 127A 0.7 s, \\ •, \ \ \ t: ^ ^ "N Discharge Characteristics (0oC732"F.40oc/l(MuF) V\ A 0.37 >A 2A \ \ \ \ \ -1 SA a <-"«" ireo , I • 3 5 10 (mini 20 7 5A JO W I04T) V\ LA _L_ 37 5A . OA 22.5 A ISA •\ W) 1 Discharge Time 2 3 5 (h) 10 20 30 1 1IHI5IMI 1mA) III 1 15 111 (A) 1 Discharge Current *l« ^SM mm For more information, including details on recycling ELK batteries and MSDS for this product, please visit www.elkproducts.com or call us at (828) 397-4200. PRODUCTS